Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Ac Sheet Roof Work
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of ac-sheet-roof-work Tenders

List of latest ac-sheet-roof-work Tenders in Indian Tenders. Click on any ac-sheet-roof-work Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for ac-sheet-roof-work Tenders.

Advance Search
  • All-Tenders (60)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Public Administrative Department
image image
Government Departments
TRN :49019871 |  21 May, 2025
Tender Value : 8.47 Lacs
 Agra - Uttar Pradesh
Tender for tender for repair work of zone-1 ward no. 16 ratanpura nagla vida community hall. - cleaning of the site for warkable etc. all complete. (non scheduled) 2 1:5:10 (1 cement : 5 coarse sand (zone-iii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (dsr 2023 sh-4.1.10 ) 3 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in :cement mortar 1:4 (1 cement : 4 coarse sand) (dsr 2023 sh-6.4.1 ) 4 brick work 7 cm thick with common burnt clay f.p.s. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level. (dsr 2023 sh-6.8 ) 5 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,taircases and spiral stair cases above plinth level up to floor fiveevel, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(dsr 2023 sh-5.3 ) 6 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500d or more(dsr 2023 sh-5.22.6) 7 centering and shuttering including strutting, propping etc. and removal of form work for :columns, piers, abutments, pillars, posts and struts(dsr 2023 sh-4.3.3 ) 8 12 mm cement plaster of mix : 1:4(1 cement: 4 fine sand)(dsr 2023 sh-13.1.1 ) 9 structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(dsr 2023 sh-10.1 ) 10 providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.fire retardant plywood conforming to is: 5509(dsr 2023 sh-9.126.2 ) 11 providing and fixing isi marked is:1341 m.s. pressed butt hinges bright finished with necessary screws etc. complete :)75x47x1.70 mm (dsr 2023 sh-9.55.3 ) 12 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/ suede finish with high density protective surface layer and reverse side ofdhesive bonding quality conforming to is : 2046 type s including cost of adhesive of approved quality. 1.0 mm thick (dsr 2023 sh-9.127.2 ) 13 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre (dsr 2023 sh-13.41.1 ) 14 painting steel work with deluxe multi surface paint to give an even shade. two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture(dsr 2023 sh-1021sub head : 13 finishing13.48.3 ) 15 providing & fixing white vitreous china water closet squatting pan (indian type) along with “s” or “p” trap including dismantling of old wc seat and “s” or “p” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of engineer-in charge. long pattern w.c pan of size 580x440 mm (dsr 2023 sh-14.80.1) 16 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require white vitreous china flat back wash basin size 450x 300 mm with single 15mm c.p. brass(dsr 2023 sh-17.7.7) 17 providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white pvc automatic flushing cistern, with fittings, standard size c.p. brass flush pipe, spreaders with unions and clamps (all in c.p. brass) with waste fitting as per is: 2556, c.i. trap with outlet grating and other couplings in c.p. brass, including painting of fittings and cutting and making good the walls and floors wherever required(dsr 2023 sh-17.5.1 ) 18 providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white p.v.c. automatic flushing cistern, with fittings, standard size g.i./ pvc flush pipe for back and front flush with standard spreader pipes with fittings, g.i clamps and c.p. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required: single squatting plate with 5 litre p.v.c. automatic flushing cistern(dsr 2023 sh-17.6.1 ) 19 providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer-in-charge :flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent.(dsr 2023 sh-11.55.1 ) 20 providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to isi : 12701, colour of opaque white or as approved by engineer-in- charge. the rate includes making necessary holes for inlet, outlet & over flow pipes. the base support i/c fittings & fixtures for tank shall be paid separately 21 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized pvc medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of engineer -in-charge100 mm nominal size dia 22 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized pvc medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of engineer -in-charge150 mm nominal size dia 23 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply and all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one stepcpvc solvent cement and testing of joints complete as per direction of engineer in charge. internal work - exposed on wall 15 mm nominal dia pipes 24 providing and fixing ptmt bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gms 25 providing and fixing ptmt stop cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms) 26 mirror of superior make glass 60x45 cm 27 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 600x600 mm 28 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 29 supply and fixing of light fitting switch board. (none sheduled) 30 supply and fixing wiring of light point. (none sheduled) 31 s/l/j of 20mm dia pvc cunduct pipe etc. all complete. 32 supply & fixing of wiring sub main. 33 supply & fixing of plug point 15mm. 34 lettering & painting of wall etc. all complete. 35 supply & fixing of 27watt. cfl etc. all complete. 36 carriage of materials by manual labour including loading, unloading and stacking for lead less than 01-50 mtrm.207.34+30.42 every 50 additonal meter 37 stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. 7.38.1 8mm thick (mirror polished and machine cut edge) 7.38.1.1 granite stone of any colour and shade 38 constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast r.c.c. horizontal grating with frame complete as per standard design :with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 39 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 40 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 41 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.) 42 stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (to be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :8.14.1 red sand stone - exposed face fine dressed with rough backingt 43 marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :raj nagar plain 44 providing and fixing stainless steel ( grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)(dsr 2023 sh-10.28 ) 45 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). (dsr 2023 s h) 46 supply & fixing granite stone work display board (size 2.50ft x 4.00ft) including painting, lettering etc. all complete. (none schedule) 47 sub total 48 add/deduction rs. for estimate figure amount match 49 grand total
  • View Tender
  • Document
  • Bid Support
2 Industrial Development Agencies
image image
corporations/Associations/Others
TRN :49022411 |  20 May, 2025
Tender Value : 15.20 Lacs
 Thane - Maharashtra
Tender for maintenance and repair to nrb @wagle industrial area... premonsoon work of providing & laying tarpaulin sheet over a.c. sheet roofat division offices 1 & 2 thane.
  • View Tender
  • Document
  • Bid Support
3 Housing Urban And Rular Development
image image
Local Bodies
TRN :49022842 |  16 May, 2025
Tender Value : 8.07 Lacs
 Raebareli - Uttar Pradesh
Tender for tender for construction work of 04 m.m.i.g. buildings in amol vihar yojna - earth workinfoundation in ordinary soil ( loamclay,or sand) including lift upto 1.5 metre ( 5fts) and lead upto 30m. (100fts.)andincludingfilling watering and raming of excavatedearthintotheplinth and removal anddisposalof surplus earth and directedby the engineer - in - chargeupto a distance of 30m. ( 100 fts ) from the foundation trenches. 2 earth work in cutting or in embankment in ordinary soil, excavation to be in form of regularpitsnotexceeding1/2 mt (20) in depth and earthwork inembankmenttobein20cm (8) layers, including ramming anddressingthesurfaceto requiredlevelsandslopesand alsoincluding1.5mts(5fts)lifts and 30mt (100fts) lead. the earth from cutting to be used in makingembankmentsortobe deposited as spoil banks with in30mts(100fts)distanceas directedbytheengineerin charge,includingcartageof8km. 3 concrete with4cm. (1*1/2) gauge brick ballast, fine local sand of 1.25 fineness modulous andcementin proportion of 8: 4:1infoundationsand under floors, includingsupply of allmaterials,labourand t&p etc.requiredforpropercompletion of the work. 4 providingandlayinginposition specified grade of reinforced cement concrete, excluding cost of centering, shuttering, finishing and reinforcement in 1: 11/2 : 3 ( 1 cement, 11/2 coarse sand , 3 20mm graded stone aggregate. 5 foundations,footings,basesof columns, etc. for massconcrete 6 columns,pillars,piers,abutments, posts and struts 7 suspended floors, roofs, landings, balconies and accessplatform 8 mildsteelorironinplain worksuchasreinforced concreteorreinforced,brick work(when notincluded inan over all rates ) wroughtto required shapeasnecessary includingbendingforproper completion of the work and including supply of steel its wastagebendhooksand authorised over lapping shallbemeasured. 9 brick work in comman burnt clay (non-modular)bricks of class 150 in super structure aboveplinthlevelincluding supplyoflabour,materialand t&prequiredforproper completionofworkincement mortar 1:6 ( 1 cement: 6 coarsesand) 10 class150 brick work in1:4 cementand coarsesand mortarinsuper - structureforwallthickness 12 cms 11 12mmthickcementplasterof mix1:4(1cement:4coarsesand) 12 providing &layingof lightcinderfillingunderfloorof toilets & other sunken roofs. 13 providingandfixinginwall unplasticisedrigidpvcrain waterpipesconformingtois: 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermalexpansion,(i)singlesocketed pipes. 110 mm dia 14 providingwoodworkinframe ofdoors,windows,celerestory windowsandotherframes, wrought frames and fixed in positionwithholdfastlugsor withdashfastnersofrequired dia and lenghts (hold fast lugs or dashfastnersshallbepaidforseperately): sal wood 15 providingandfixingangleiron framesfordoors,windowsand ventilatorsofmildsteelangle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t- ironframeortothewallwith dash fastener, including fixing of necessary butt hinges and screwsandapplyingapriming coatofapprovedsteelprimer, all complete as per the direction ofengineer-in-charge.(fordoorframes) 16 providingandfixingisimarked flush door shutter confirming to is:2202(part1)non-decorative type, core of blockboard constructionwithframeoffirst classhardwood andwell matched commercial 3 ply veneering with vertical grains or cross bands and face vineers on both facesof shutters:35mm thick including isi marked stainlesssteelbutthingeswithnecessary screws. 17 providingandfixingwiregauge shutterusinggalvanisedms wiregaugeofaveragewidthof apurture1.4mminboth directionwithwireofdia 0.63mm for doors, windows and celestorywindowswithhinges and necessary screws. 35mm thick shutter, with isi marked mspressedbutthingesbright finished of required size withsecond class teak wood. 18 steelworkweldedinbuiltup sections/framedwork, including cutting, hoisting, fixing inpositionandapplyinga primingcoatofapprovedsteel primer using structural steel etc. asrequired.ingratings,frames, guard bar, ladder, railings, brackets,gatesandsimilarworks(forwindow grills) 19 providingandfixingaluminium towerbolts,isimarked, anodised (anodic coating not lessthangradeac10asper is:1868) transperent ordyed to required colour or shed, withnecessary screws etc. complete. 150 x 10mm+ 20 250 x 10 21 providingandfixingaluminium sliding door bolts, isi marked anodised anodic coating not less thangradeac10asperis: 1868),transparentordyedto requiredcolourorshade,with nutsandscrewsetc.complete:250x16 mm 22 providingandfixingaluminium hangingfloordoorstopper,isi markedanodised(anodic coatingnotlessthangradeac-10asperis:1868)transparent ordyedtorequiredcolourand shed, with necessary screws etccomplete. twin rubber stopper. 23 mildsteelorironwork of heavy sizes and sections such as holdingdownbolts,holdfast, tie, rods gratings etc (when not included in an over all rates) wrought to required form, includingsupplyofsteel,bolts, nutsandwastageetcandtheir fixingrequiredtoproper completionofwork.(fortubular stair case railing) 24 providingandlayingvitrified floortilesindifferentsizes (thickness to be specified by the manufacturer) with water absorptionlessthan0.08%and conforming to is : 15622, of approved make, in allcolours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarsesand),includinggrouting the joints with white cement and matching pigmentsetc.,complete. size of tile 600x600 mm 25 providingand laying vitrified tilesin differentsizes (thickness tobespecifiedby manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in allcolours &shade,inskirting,riserof steps,over12mmthickbedof cement mortar 1:3 (1 cement: 3 coarsesand),includinggrouting thejointwithwhitecement& matching pigments etc.complete. size (600x600) 26 marblestoneflooringwith18 mmthickmarblestone,asper sampleofmarbleapprovedby engineer-in-charge, over 20 mm (average)thickbaseofcement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith grey cement slurry, including rubbingand polishing complete with : udaipur green marble 27 providingandfixingfirstquality ceramic glazed wall tile confirmingtois:15622 (thickness to be specified by the manufacturer)ofapproved makeinallcolours,sheds exceptburgandy,bottlegreen, black of any size as approved by engineerincharge,inskirting, rizersofstepanddados,over 12mmthickbedofcement mortar1:3(1cement:3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mix with pigment ofmatching shed complete. 28 providing and laying ceramic glazed floor tiles of size 300x300 mm(thicknesstobespecified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours suchaswhite,ivory,grey, fume red brown, laid on 20 mm thickcementmortar1:4(1 cement : 4 coarse sand), includingpointingthejoints with white cement and matchingpigment etc, complete. 29 providing and applying white cementbasedputtyofaverage thickness1mm,ofapproved brand and manufacturer, over the plastered wall surface to prepare the surface even andsmooth complete. 30 finishing walls with acrylic smoothexteriorpaintof required shade on new work (twoormorecoatapplied@1.67ltr/10sqmoverand includingprimingcoatof exterior primer applied @ 2.20kg/ 10 sqm) 31 wallpaintingwithacrylic emulsionpaint,havingvoc (volatile organic compound ) content less than 50 grams/ litre, of approved brand and manufacture,includingapplying additional coats wherever required, to achieve even shadeand colour. two coats 32 paintingwithsyntheticenamel paint of approved brand and manufactureofrequiredcolour togiveanevenshade:twoor morecoatsonnewworkover an undercoatofsuitable shade with ordinary paint of approvedbrand and manufacture 33 providing and fixing white vitreouschinapedestaltype water closet (european type) withseatandlid,10litrelow level white vitreous china flushingcistern&c.p. flush bend with fittings & c.i.brackets,40 mm flush bend, overflow arrangement with specials of standard make and mosquito proofcouplingofapproved municipaldesigncomplete, including painting of fittings and brackets, cutting and making good thewallsandfloorswherever required : w.c. pan with isi markedwhitesolid plastic seat and lid 34 providingandfixingwashbasin withc.i.brackets,15mmc.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making goodthewallswhereverrequire: whitevitreouschinawash basin size 630x450 mm with a pairof15mmc.p.brasspillartaps 35 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittingscomplete. semi rigid pipe 32 mm dia 36 providing and fixing cp brass bibcock of approved quality confirming to is: 8931 15mm nominal bore. 37 s/f of 15mm nominal bore cpvc pipe all complete. 38 providing and fixing cp brass angle valve for basin mixer and geyser points of approved quality confirming to is:8931 15mm nominal bore. 39 15mm nominal boare 40 providing and fixing cp brass shower mixer of 15 or 20mm bore including cp brass connection with angle valve of standard design and approved make confirming to is:8931 41 providing and fixing cp brassover head shower with 15 or 20 mm inlet including connection complete: 100mm diameter. 42 providing and fixing trap of selfcleansing design with screwed down or hinged grating with or with out vent arm complete, including cost of cutting chases and making good the walls and floors:100mm inlet and 100mm out let pvc 43 100mm inlet and 75mm outlet pvc 44 providing and placing on terrace (at all floor levels) polyethylene water storage tank, isi : 12701 marked, with cover and suitable locking arrangement andmaking necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 45 providing, fixing and jointing pvc pipes of different diameters with with pvc solvent cement (or as per manufacturers specifications) with or without sockets (if sockets are provided with pipe length) in vertical sewage line, waste water line and vent line with all necessary bends, angle bends, tees, elbows ms bat clamps along with all necessary fastners and bolt with cutting chases and making good the walls and floors wherever required including testing of the same all as per direction and satisfaction of engineer in charge.6kg per sqin pressure pipe75mm inner dia. 46 6kg per sqin pressure pipe110mm inner dia. 47 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot and cold water supply, including all cpvc plain and brass threaded fittings, including fixing the pipe with clamps 1.00m spacing. this includes jointing the pipes and fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 15mm nominal outer dia pipes. 48 25mm nominal outer dia pipes. 49 constructing masonary chamber 30x30x50cminside,inbrick workincementmortar1:4(1 cement:4coarsesand),with ci surface box 100x100x75 mm(inside)withhingecover fixed in cement concrete slab 1:2:4 ( 1 cement : 2 coarse sand:4 graded stone aggregate 20mm nominal size) including necessary excavation, foundationconcrete1:5:10(1cement:5finesand:10graded stoneaggregate40mmnominal size)andinsideplasteringwith cement mortar1:3 ( 1 cement : 3coarsesand)12mmthick, finishedwithafloatingcoatof neat cement complete as perstandard design: 50 supply delivery errection the fabricatedmsboardofsuitable sizeonwhichthefollowing supplieditemsshallbefixedas per the direction of enggincharge. 51 (a)supply and fixing 63 ampdoublepole(singlephase &neutral)240voltresidual currentcircuitbreakerrccb havingasensivitycurrentup to300 ma on the existing ms board complete with connection testing&commissioningetcas required. 52 (b)supplying & fixing 2+8way single door prewired sp&n mcb distribution board of sheet steel for240voltonexistingms board complete with dpmcb isolator40amp240volt1no& 25amp single pole240 volt spmcb(c)series5nos completeduly wired with 4sqmm fr pvc insulated copper conductorupto terminal box tinned copper busbar ditachable gland plate, inter connection phosphotized &powder coated includingearthingetcasreq( for power distribution ) 53 (c)supplying & fixing 2+8way single door prewired sp&n mcb distribution board of sheet steel for240voltonexistingms board complete with dpmcb isolator40amp240volt1no& 10amp single pole240 volt spmcb(c)series5nos completeduly wired with 4sqmm fr pvc insulated copper conductorupto terminal box tinned copper busbar ditachable gland plate, inter connection phosphotized &powder coated includingearthingetcasreq( for light distribution ) 54 wiring point for lightwith 1.5sq mmfrpvcinsulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceilingrose/angle/batten holderon3mmthickphenolic laminated backalite sheet etc comp in all respect 55 wiringpointforfan 1.5sq mmfrpvcinsulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceiling roseon3mmthick phenolic laminated backalite sheet &fan boxetccompin all respect 56 wiringpointfor freshairfan with 1.5sq mmfrpvc insulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceiling roseon3mmthick phenolic laminated backalite sheetetc comp in all respect 57 supply&fixing5ampmodular switch & 5amp 5pin modular socketontheexistingmodular plateandswitchboxincluding connection etc as reqd. 58 supply&fixingofpowerplug 20amp250voltflushtype modular switch& 5pin 20amp 250voltmodular socket on concealedmsbox etc.asrequered 59 supply & wiring for power pointwith2no4sqmmfrpvc insulated1100voltgrade multistrandsinglecorecopper conductor cable in 20mm dia heavydutypvcconduitwith1 no2.5sqmmfrpvcinsulated multistrandcopperconductor cable as earth continuity wire in conduit etc as required 60 wiringofcircuitalongwith earth wire with the following size of fr pvc insutated copper conductorsinglecorecablein recessed medium class 20mm dia pvc conduit as required 61 1x1.5sqmm+1x1.5sqmm 62 supply & fixing of electronic fan regulatormodular400w 120v-- 280v isi marked on existing switchboard includingmaking connection etc for proper completion of work 63 supply&burryingofsafe earthingelectrodet-19zn-zinc coated,lengthupto3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mmx2.6mm, terminaldia12mm,coating80- 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc)capable of reducingthe soilresistivitywith good mixture of retaining capacityandoneearthinglead of 20mmx3mmg.i. strip,up to switch board (from apron to switchboard,thecostofg.i. strip will be extra)along with 30cm square c.i. frame with hinged cover & masonary housing 64 supplying&layingof 20mmx3mm g.i. strip directly in ground&onwallasrequired complete in all respect (from apron to switch board. 65 wiring for submain withthe 2x10sqmm size fr pvc insulated copper conductor cable in recessedmediumclasspvcconduit as required 66 boring with hydraulic piling rigs with power units, providing and installingcastinsitusingleunder reamedpilesofspecifieddiameter andlengthbelowpilecapinm-25 cementconcrete,tocarryasafe working load not less than specified, excluding the cost of steel reinforcement but including thecostofboringwithbentonite solutionandthelengthofthepile to be embedded in pile cap etc. all complete.(lengthofpilefor payment shall be measured upto tothe bottom of pile cap) : 300 mm dia piles 67 s/f of kitchen sink including all labour and t&p all complete. 68 15mm thick plaster in 1:4 (1 cement and 4 coarse sand) including all labour complete. 69 s/f of gate valve including all labour and t&p all complete 70 s/f pvc bulb holder including all labour and t&p all complete 71 s/f aluminium door handle including all labour and t&p all complete 72 s/f of chequered tiles on ramp of house including all labour and t&p all complete 73 s/f flange bib cock with z spray including all labour and t&p all complete 74 s/f of kota stone on rear court yard anf front porch of house including all labour and t&p all complete 75 s/f of granite stone on kitchen top of house including all labour and t&p all complete 76 s/f of basin mixture including all labour and t&p all complete 77 s/f of 25mm cpvc pipe including all labour and t&p all complete
  • View Tender
  • Document
  • Bid Support
4 Civil Work
image image
State Government
TRN :49029493 |  15 May, 2025
Tender Value : 32.33 Lacs
 Gautam Buddha Nagar - Uttar Pradesh
Tender for construction of e-library room in village begmabad yea. wc-06 - earth work in excavation in ordinary soil in all of foundation trenches including dressing of the side and ramming of bottom.lifts up to 1.50 m including getting out theexcavated soil and disposal of surplus excavated soil as directed with in a lead of 50m. (most/a.r./yeida) 2 supplying chemical emulsion in sealed containers including delivery as specified. chlorpyriphos/ lindane emulsifiable concentrate of 20%. (dar/2.34.1/based on uppwd/sor-2020)) 3 diluting and injecting chemical emulsion for post-constructional anti-termite treatment (excluding the cost of chemical emulsion) : treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 coarse sand) to match the existing floor: with chlorpyriphos/lindane e.c. 20% with 1% concentration (dar/2.35.3.1/based on uppwd/sor-2020)) 4 2.5 cm thick damp proof course with cement and approved coarse sand 1:1½ with and including water proofing as ordered by the engineer incharge in the proportion as specified by the manufacturer including supply of all materials, labour, tools & plants etc. required for proper completion of the work and including proper curing & shutterings as necessary. (uppwd/sor-2020/361) 5 applying a coat of residual petroleum bitumen of grade of vg-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 6 cement concrete with 4cmgauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all material, labour, tools&plants etc required for proper completion of the work. 7 b/w with bricks of class 150 in foundation & plinth in cm 1:4 (based on up pwd sor 2020) cement mortar 1:4 ( 1cement :4coarse sand) 8 m-150 brick work in 1:4 one cement and four course sand 2.20 f.m. mortar superstructure but for walls of half brick thick including supply of all material, labour, t&p etc. required for proper completion of the work. (uppwd/sor-2020/305(a)+310a 9 m-150 brick work in 1:4 one cement and four course sand 2.20 f.m. mortar superstructure but for walls of half brick thick including supply of all material, labour, t&p etc. required for proper completion of the work. (uppwd/sor-2020/305(a)+310a 10 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry.uppwd-sor-2020-dar-18/6.15/ 11 providing and laying in position machine batched and machine mixed design mix m-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer-in-charge. (note :- cement content considered in this item is @ 330 kg/cum. excess/ less cement used as per design mix is payable/recoverable separately). all works upto plinth level 12 providing and laying in position machine batched and machine mixed design mix m-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer-in-charge. (note :- cement content considered in this item is @ 330 kg/cum. excess/ less cement used as per design mix is payable/recoverable separately).all works above plinth level upto floor v level 13 centringand shutteringincluding strutting, propping etc. andremoval of form for : foundation footings, base of column 14 centringand shutteringincluding strutting, propping etc. andremoval of form for : lintels, beams, plinth beam, grinder 15 centringand shutteringincluding strutting, propping etc. andremoval of form for : suspended floors, roofs, landings 16 columns, pillars, piers, abutments, posts and struts. (dar/5.9.6/based on uppwd/sor-2020)) 17 edges of slabs and breaks in floors and walls:under 20 cms wide. (dar/5.9.16.1/based on uppwd/sor-2020)) 18 earth work in rough excavation , banking excavaated earth in layers not exceeding 20 cm in depth, breaking clods watering, rolling each layer with 1/2 tonnes roller or wooden or steel rammer and rolling every 3rd and top most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, all leads as per(a.r. )for all kind of soil. 19 steel rainforcement for r.c.c. work including straightening, cutting bending, placing in position and binding all complete upto plinth level thermo-mechanically treated bars of grade fe-500d or more./cold twisted bars. (dar/5.22.6/based on uppwd/sor-2020)) 20 12mm cement plaster of mix: 1:6 (1 cement : 6 coarse sand)based on up pwd sor 2020 dar-18/13.4.2 21 6mm cement plaster of mix: 1:3 (1 cement : 3 coarse sand)based on up pwd sor 2020 dar-18/13.17 22 15mm cement plaster of mix: 1:6 (1 cement : 6 coarse sand)based on up pwd sor 2020 dar-18/13.4.2 23 finishing walls with acrylic smooth exterior paint of required shade: new work (two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 24 distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade 25 providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.dar-18/13.26 26 painting with synthetic enemel paint of approved brand and manufacture to give an even shade: two or more coats on new work. 27 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 110mm dia 28 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. single tee with door 110x110x110 mm (dar/12.42.3.2/based on uppwd/sor-2020) 29 bend 87.5° 110 mm bend (dar/12.42.5.2/based on uppwd/sor-2020) 30 shoe (plain) 110 mm shoe (dar/12.42.6.2/based on uppwd/sor-2020) 31 providing and fixing unplasticised -pvc pipe clips of approved design to unplasticised - pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm (dar/12.43.2/based on uppwd/sor-2020) 32 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.(dar/12.44/based on uppwd/sor-2020) 33 steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.dar-18/10.25.2 34 providing and fixing water closet squatting pan (indian type w.c. pan with 100mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required white vitreous china orissa pattern w.c. pan of size 580x440mm with integral type foot rests.up pwd sor-2020-dar 18/17.1.1 35 providing and fixing wash basin with c.l. brackets, 15 mm c.p. brass pillar taps,32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:uppwd sor-2020-dar 17.7.1 36 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.20mm od pipes. (dar/18.8.2/based on uppwd/sor-2020) 37 25mm od pipes. (dar/18.8.3/based on uppwd/sor-2020) 38 providing and fixingbrass gate valve with c.i. wheel of approved quality (screwed end) : 25 mm nominal bore. (dar/18.17.1/based on uppwd/sor-2020) 39 32 mm nominal bore. (dar/18.17.2/based on uppwd/sor-2020) 40 providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer-in-charge over the rcc slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) after two days of proper curing applying a second coat of cement slurry using 2.75kg! sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer-in-charge. d) finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand) admixed with water proofing compound conforming to is: 2645 and approved by engineer-in-charge including laying glass fibre doth of approved quality in top layer of plaster and finally finishing the surface with trowe’ with neat cement suvr an making pattern ot 300x300 mm square 3mm deep. e) the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. all above operations to be done in order and as directed and specified by the engineer-in-charge: dar18/22.7.1 41 providing and placing on terrace (at all floor levels) polyethylene water storage tank isi: 12701 marked with cover and suttable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank dar 18/ 18.48 42 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - iii) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.(dar 2018-4.17)based on uppwd sor/2020 43 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600mm (dar/11.41.2/based on uppwd/sor-2020)) 44 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (dar/8.31/based on uppwd/sor-2020)) 45 providing and fixing brass bib cock of approved quality: 15 mm nominal bore (dar/18.15.1/based on uppwd/sor-2020)) 46 providing and fixingbrass gate valve with c.i. wheel of approved quality (screwed end) : 25 mm nominal bore. (dar/18.17.1/based on uppwd/sor-2020) 47 providing and fixing nahani trap 75x100mmincluding all complete. 48 20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand-dar-18/13.6.1/p-902 49 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30mm thick including isi marked stainless steel butt hinges with necessary screws. (dar/9.21.2/based on uppwd/sor-2020)) 50 extra for providing isi marked stainless steel butt hinges instead of m.s. pressed butt hinges bright finished of required size with necessary screws. (shutter area to be measured). (dar/9.14/based on uppwd/sor-2020)) 51 renewing panes of glass in door, window & ventilators or fixing in the new work with 3mm thick glass panes fixed with brads & putty includung supply of all material , labour , tools & plants required for proper completion of workuppwd sor 2020/p26/806 52 prroviding and fixing isi mark 3 layer prelaminated particle board conforming to grade 2 type-iii of is-12823/20b laminated with 0.6-0.8 mm thick laminate conforming to is-2046/1995 and balancing lamination of 0.5 mm thick on the back side (size 700*750*430) including all complete 53 supply of work sb collection office/visitor chain with sheat dxwxh 400*400*450 mm padded with polyurithane foam complete 54 supply wook at site sb collection executive table of 3 layer prelaminated particle board (wood product) of grade 2 type 2 of is-12823/latest 1830 mm 950 mm 750mm including all complete 55 supplying and filling in plinth with jamuna sand under floors, including watering, ramming, consolidating and dressing complete. dar-18/2.27 56 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 57 constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast r.c.c. horizontal grating with frame complete as per standard design with common burnt clay f.p.s. (non modular) bricks of class designation 7.5.(dar/18.33.1/based on uppwd/sor-2020) 58 providing, laying and jointing glazed stoneware pipes class sp-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : (dar/19.1.1/based on uppwd/sor-2020) 59 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round s.w. pipes including bed concrete as per standard design : (dar/19.2.2/based on uppwd/sor-2020) 60 providing and fixing square-mouth s.w. gully trap class sp-1 complete withc.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (dar/19.4.1/based on uppwd/sor-2020) 61 providing and fixing heavy class ss gratingof approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and ft, ut & fd.size 150 mm x 150 mm 62 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.(dar/17.73.2/based on uppwd/sor-2020)) 63 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. (dar/17.31/based on uppwd/sor-2020)) 64 providing and fixing ptmt soap dish holder having length of 138mm, breadth102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (dar/18.65/based on uppwd/sor-2020)) 65 providing and fixing chicken wire mesh (murga jali) 24 gauge and 20 mesh at junction of rcc and masonry walls including fixing in position with steel nails of 25 mm in length as approved at required as directed by engineer-in-charge, scaffolding etc. complete. (ar/yeida//based on uppwd/sor-2020))½x24 gauge 66 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.(dar/9.101.1/based on uppwd/sor-2020))single rubber stopper 67 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:250x10mm(dar/9.97.2/based on uppwd/sor-2020)) 68 providing and fixing aluminium handles,isi marked, anodised (anodic coating not less than grade ac 10 as per is: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.125 mm (dar/9.100.1/based on uppwd/sor-2020)) 69 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour.25mm nominal bore, weighing not less than 62 gms. (dar/18.75.3/based on uppwd/sor-2020)) 70 providing & fixing of cp heavy duty bottle trap 32mm. (complete complying with relavent standard specification and as directed by the competent authority.) for wash basin&urinal 71 providing and fixing 1 mm thick m.s. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm m.s. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and t- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer up pwd sor-2020-dar-18/10.4 72 construction of granular sub-base by providing close graded material, mixing in mechanical mix plant at omc, carriage of mixed material to work at site, spreading uniform layers with motor grader on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 for grade-1 material. (morth/(ar/yeida/based on uppwd/sor-2020) 73 providing and laying 60mm thick i.s.i. mark factory made cement concrete interlocking concrete paver block made by block making machine with strong vibratory compaction of approved size, design, shape, laid in required colour and pattern over and including average 50mm thick compacted bed coarse sand and filling the joints with fine sand all complete as per the direction of engineer-in-charge with conforming to is-15658 and irc:sp:63. (ar/yeida/ based on uppwd/sor-2020) 74 wiring point for light in 1.5 sq. mm. pvcinsulated singlecorecopperconductor cable (inpvcconduit with 1.5sq.mm. frlsh pvc insulated multistrand copperconductor cable as earth wire drawn inside conduit.)and5 amp.flush typeswitch& ceiling rose/angle/batten holderfixedwith3mmthickphenolic laminate backalitesheet withbrass machinescrews andcup washers mounted overexisting m.s.switch boardbox/junction boxwith supplyofallmaterial, labour& t&p etc. requiredforproper completion of the work complete in all respect, as directed by engineer in charge pwd-2018 ps no-174c 75 supply and wiring of submains with 2 nos. of 2.5 sq. mm. frlsh pvc insulated1100 vgrade multistrand singlecore copper conductorcable in 25mm dia heavy duty (2mm thick) pvc conduitwith2 nos 2.5 sq.mm.frlsh pvc insulated multistrand copperconductor cable asearth continuity wire drawn in conduit complete in all respect, as directed by engineer in charge pwd-2018 ps no-261c 76 supply and fixing of power plug with 20 amp./250 voltflush type modularswitchand 5 pin 20 a/250 voltflush typeuniversal modular socket switch on concealed m.sboxincluding supply of allmaterial, labourt&petc. complete in all respect, as directed by engineer in charge .pwd-2018 ps no-1139a 77 s&f surface/flush mounting 8 ways spn distribution board with additional metal door without mcb complete in all respect, as directed by engineer in charge. pwd-2018 ps -1024a 78 s&f of 6 amp to 32 amp. mcb (10 ka) c curve complete in all respect, as directed by engineer in charge.pwd-2018ps -1002cat-a 79 s&f of 40amp. dp mcb (10 ka) c curve complete in all respect, as directed by engineer in charge. pwd-2018 ps no-1010 cat-a 80 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. (dar/10.18/based on uppwd/sor-2020))
  • View Tender
  • Document
  • Bid Support
5 Metals And Minerals
image image
Central Government/Public Sector
TRN :34404893 |  12 May, 2025
Tender Value : 0
 Jamshedpur - Jharkhand
Tender for gem bids for clearing jungle including uprooting of rank vegetation grass brush wood trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. "supplying chemical emulsion in sealed containers including delivery as specified. chlorpyriphos or lindane emulsifiable concentrate of 20 percent" "diluting and injecting chemical emulsion for post constructional anti termite treatment excluding the cost of chemical emulsion along external wall where the apron is not provided using chemical emulsion at the rate 7.5 litres or sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall and rodding etc. complete isto with chlorpyriphos or lindane e.c. 20 percent with 1 percent concentration" "earth work in excavation by mechanical means hydraulic excavator or manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m all kinds of soil." filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m supplying and filling in plinth with sand under floors including watering ramming consolidating and dressing complete. "providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1 isto 3 isto 6 1 cement 3 coarse sand zone iii 6 graded stone aggregate 20 mm nominal size " "providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering shuttering finishing and reinforcement all work up to plinth level isto 1 isto 1.5 isto 3 1 cement 1.5 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size " "reinforced cement concrete work in walls any thickness including attached pilasters buttresses plinth roof and string courses fillets columns pillars piers abutments posts and struts etc. above plinth level up to floor five level excluding cost of centering shuttering finishing and reinforcement 1 isto 1.5 isto 3 1 cement 1.5 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size " brick work with common burnt clay f.p.s. non modular bricks of class designation 7.5 in foundation and plinth in cement mortar 1 isto 6 1 cement 6 coarse sand brick work with common burnt clay f.p.s. non modular bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1 isto 6 1 cement 6 coarse sand "half brick masonry with common burnt clay f .p .s. non modular bricks of class designation 7.5 in superstructure above plinth level up to floor v level. cement mortar 1 isto 4 1 cement 4 coarse sand " "centering and shuttering including strutting propping etc. and removal of form for foundations footings bases of columns etc. for mass concrete" "centering and shuttering including strutting propping etc. and removal of form for suspended floors roofs landings lintals beams balconies and access platform" "steel reinforcement for r.c.c. work including straightening cutting bending placing in position and binding all complete upto plinth level thermo mechanically treated bars of grade fe 500d or more make sail or tata or jindal " "15 mm cement plaster on the rough side of single or half brick wall of mix isto 1 isto 6 1 cement isto 6 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " "12 mm cement plaster of mix 1 isto 6 1 cement isto 6 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " "6 mm cement plaster of mix 1 isto 3 1 cement 3 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " neat cement punning. "finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade new work two or more coats applied at the rate 1.43 ltr or 10 sqm over and including priming coat of exterior primer applied at the rate 2.20 kg or 10 sqm make dulux or burger or asian paints or as per direction of eic" white washing with lime to give an even shade new work three or more coats mix with fevicol ddl and robin blue or as per direction of eic "painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. preferable make dulux or burger or asian paints or as per direction of eic make dulux or burger or asian paints or as per direction of eic" making plinth protection 50mm thick of cement concrete 1 isto 3 isto 6 1 cement 3 coarse sand zone iii 6 graded stone aggregate 20 mm nominal size over 75mm thick bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling and dressing and finishing the top smooth "providing and fixing angle iron frames for doors windows and ventilators of mild steel angle sections of size 35x35x5 mm joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t iron frame or to the wall with dash fastener including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer all complete as per the direction of engineer in charge. make sail or tata or jindal " "providing and fixing isi marked flush door shutters conforming to is isto 2202 part i decorative type core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including isi marked stainless steel butt hinges with necessary screws" "structural steel work in single section fixed with or without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete. make sail or tata or jindal " 25 mm thick pvc flush door shutters made out of a one piece multi chamber extruded pvc section of the size of 762 mm into 25 mm or less as per requirement with an average wall thickness of 1 mm plus or minus 0.3 mm . pvc foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. m.s. tube having dimensions 19 mm into 19 mm and 1.0 mm plus or minus 0.1 mm is inserted along the hinge side of the door. core of the door shutter should be filled with high density polyurethane foam. the top and bottom edges of the shutter are covered with an end cap of the size 25 mm into 11 mm. door shutter shall be reinforced with special polymeric reinforcements as per manufacturer specification and direction of engineer in charge to take up necessary hardware and fixtures. stickers indicating the locations of hardware will be pasted at appropriate places "providing and fixing isi marked oxidised m.s. sliding door bolts with nuts and scrows etc. complete .as per the direction of directions of engineer in charge.300x16 mm " "providing and fixing ist quality ceramic glazed wall tiles conforming to is 15622 thickness to be specified by the manufacturer of approved make somany or kajaria or nitco in all colours shades except burgundy bottle green black of any size as approved by engineer in charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1 isto 3 1 cement 3 coarse sand and jointing with grey cement slurry at the rate 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. make isto somany or kajaria or nitco or asian or as per direction of eic" "providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer with water absorption less than 0.08percent and conforming to is 15622 of approved make in all colours and shades laid on 20mm thick cement mortar 1 isto 4 1 cement 4 coarse sand jointing with grey cement slurry at the rate 3.3 kg or sqm including grouting the joints with white cement and matching pigments etc. complete. size of tile 600x600 mm make somany or kajaria or nitco or asian or as per direction of eic" "providing and fixing water closet squatting pan indian type w.c.pan with 100 mm sand cast iron p or s trap 10 litre low level white p.v.c. flushing cistern including flush pipe with manually controlled device handle lever conforming to is 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests preferable make hindware or parrywair or hindustan or cera or direction of eic" "providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and c.p. brass spreaders with brass unions and g.i clamps complete including painting of fittings and brackets cutting and making good the walls and floors wherever required one urinal basin with 5 litre white p.v.c. automatic flushing cistern preferable make hindware or parrywair or hindustan or cera or direction of eic" "providing and fixing wash basin with c.i. brackets 15 mm c.p. brass pillar taps 32 mm c.p. brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require isto white vitreous china wash basin size 630x450 mm with a single 15 mm c.p. brass pillar tap" "providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete. semi rigid pipe 32 mm dia" providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with c.p . brass screws and washers complete. "providing and fixing brass bib cock of approved quality 15 mm nominal bore" "providing and fixing brass stop cock of approved quality 15 mm nominal bore" providing and fixing circular or hexagonal cast iron or m.s. sheet box for ceiling fan clamp of internal dia 140 mm 73 mm height top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron or m.s. sheet box by means of 3.3 mm dia round headed screws one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. providing and fixing isi marked oxidised m. s handles conforming to is 4992 with necessary screws etc. complete 125 mm providing and fixing bright finished brass hanging type floor door stopper with necessary screws etc. complete. providing and fixing is 12817 marked stainless steel butt hinges heavy weight with stainless steel screws etc. complete 100x60x2.50 mm "providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work a. 15 mm dia nominal bore preferable make tata or jindal or as per direction of eic" "providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work b. 20 mm dia nominal bore preferable make tata or jindal or as per direction of eic" providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work d. 50 mm dia nominal bore preferable make tata or jindal or as per direction of eic "providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is 13592 type a including jointing with seal ring conforming to is 5382 leaving 10 mm gap for thermal expansion single socketed pipes. 110 mm diameter" "providing and fixing gun metal gate valve with c.i. wheel of approved quality screwed end isto 20 mm nominal bore" "providing and fixing gun metal gate valve with c.i. wheel of approved quality screwed end isto 50 mm nominal bore" providing and placing on terrace at all floor levels polyethylene water storage tank is isto 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank. providing and fixing 100 mm sand cast iron grating for gully trap constructing brick masonry chamber for underground c.i. inspection chamber and bends with bricks in cement mortar 1 isto 4 1 cement 4 coarse sand c.i. cover with frame light duty 455x610 mm internal dimensions total weight of cover with frame to be not less than 38 kg weight of cover 23 kg and weight of frame 15 kg r.c.c. top slab with 1 isto 1.5 isto 3 mix 1 cement 1.5 fine sand isto 3 graded stone aggregate 20 mm nominal size foundation concrete 1 isto 5 isto 10 1 cement 5 fine sand 10 graded stone aggregate 40 mm nominal size inside plastering 12 mm thick with cement mortar 1 isto 3 1 cement isto 3 coarse sand finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets isto with common burnt clay f.p.s. non modular bricks of class designation 7.5 "constructing masonry chamber 30x30x50 cm inside in brick work in cement mortar 1 isto 4 1 cement isto 4 coarse sand for stop cock with c. i. surface box 100x100 x75 mm inside with hinged cover fixed in cement concrete slab 1 isto 2 isto 4 mix 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20 mm nominal size i or c necessary excavation foundation concrete 1 isto 5 isto 10 1 cement isto 5 fine sand isto 10 graded stone aggregate 40mm nominal size and inside plastering with cement mortar 1 isto 3 1 cement isto 3 coarse sand 12mm thick finished with a floating coat of neat cement complete as per standard design isto with common burnt clay f.p.s. non modular bricks of class designation 7.5" providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level isto 1 isto 1.5 isto 3 1 cement isto 1 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter 1.8 m long complete as per standard design. with common burnt clay f.p.s. non modular bricks of class designation 7.5 "cement concrete flooring 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate finished with a floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate" "providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm plus 0.05 percent total coated thickness zinc coating 120 grams per sqm as per is 277 in 240 mpa steel grade 5 to 7 microns epoxy primer on both side of the sheet and polyester top coat 15 to 18 microns using self drilling or self tapping screws complete ridges plain 500 to 600mm " "providing and fixing precoated galvanised iron profile sheets size shape and pitch of corrugation as approved by engineer in charge 0.50 mm plus 0.05 percent total coated thickness with zinc coating 120 grams per sqm as per is 277 in 240 mpa steel grade 5 to 7 microns epoxy primer on both side of the sheet and polyester top coat 15 to 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin charge. the sheet shall be fixed using self drilling or self tapping screws of size 5.5 x 55 mm with epdm seal complete upto any pitch in horizontal or vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required." providing and fixing of glass panes with putty and glazing clips in steel doors and windows all complete with 4mm thick glass panes etc. complete. supply of led tube light fittings .make c.g. or philips fixing of led tube light fittings including supply of all hardwares as required. led fitting will be supplied by contractor. make c.g. or philips supply of 48 sweep ceiling fan complete with down rod.clamp canopy etc. fixing of 48 sweep ceiling fan complete with down rod.clamp canopy etc.fan hardwares required for fixing for i.e. nut bolts clamp screws etc wiil be supplied by contractor. supply and fixing of stepped type electronic fan regulator on existing switch board. wiring for light point fan point exhaust fan point with 1.5 sqmm frls pvc insulated copper conductor single core cable in consield with modular switch modular plate suitable gi box and earthing the point with 1.5 sqmm frls pvc insulated copper conductor cable as required. supply of frls pvc insulated copper conducter single core cable of size 6 sqmm. make havells or kei or polycab or national wiring for circuit or submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in consield or recessed medium class pvc conduit in concield as required 2 x 6 sqmm plus 1 x 6 sqmm earth wire. all the three colours should be red blue and green supply and fixing of utility db p or s 20a dp metal plug and socket distribution board grey make anchor or havells supply and installation of three phase industrial box with 32 amp 4 pole mcb and 5 pin top plug. make neptune or reputed make supply of frls pvc insulated copper conducter single core cable of size 10 sqmm. make havells or kei or polycab or national wiring for circuit or submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface or recessed medium class pvc conduit in concield as required 4 x 10 sqmm + 1 x 10 sqmm earth wire.all the five colours should be red blue yellow black and green preparation of earth pit with supply of all materials including 3m long 3.64mm thick perforted gi tube with salt and charcol in alternate layer and brick chamber at the top with chequered plate 6mm thick as per is 3043 with latest. supply and laying 25mm x 5 mm gi strip at 0.5 meter below ground or wall including connection with electrode with db. supply of all hardware are in scope of contractor supply ans fixing of surface mounting vertical type 415 volts tpn mcb distribution board of sheet steel dust proctected duly power coated painted inclusive 200 amp tinned copper bus bar common neutral link earth bar din bar for mounting mcb with provision of 100 amp tpn mccb as incomer interconnection between incomer mccb and busbar. supply and fixing of 5 to 32 amp rating 240 or 415 volt mcb suitable as per load. supply and fixing of four pole 100 amp rating 415 volt 16 ka mccb . laying of 1.1kv grade pvc al.cable of size 2 or 3 or 3.5 or 4c 2.5 or 6 or 10 or 16 or 25 or 35 sq.mm in underground trench of 760mm deepx760mm wide in single tier formation including trench excavation and back filling with bricks 15brick or m and sand protection route marker. road or concreete or bolder cutting and finishing the road to its original shape are in the scope of the contractor. supply and fixing of street light on wall including supply of all necessaryu hardware for fixing of fitting on wall. supply and fixing of bulk head fitting on wall including supply of all necessaryu hardware for fixing of fitting on wall. supply installation and commissioning of exhaust fan of size 300 mm dia. this includes cutting of wall and finishing and supply of hardware like nut bolts etc. make crompton
  • View Tender
  • Document
  • Bid Support
6 Housing Urban And Rular Development
image image
Local Bodies
TRN :48606691 |  15 May, 2025
Tender Value : 56.65 Crore
 Prayagraj - Uttar Pradesh
Tender for tender for kareli - nurulla road to askari market road block c and block d housing scheme and nurulla road from mahavir chauraha to karamat ki chowki near sasur khedari river and also till the connecting road - clearing grass and removal of rubbish upto a distance of 30 m outside the periphery of the area as per technical specification clause 201. 3 dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 60 metres as per instructions of e-i-c. (by mechanical means). 4 i) cement concrete 5 ii) reinforced cement concrete/ r.b. 6 dismantling of flexible pavements and disposal of dismantled material up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per technical specification clause 202. bituminous / granular courses (by mechanical means) 7 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 8 removing all type of hume pipes and stacking within a lead of 1000 metres including t&p, earthwork and dismantling of masonry works. 9 (i) up to 600 mm dia 10 removal of telephone / electric poles / street light / lamp post including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately 11 disposal of moorum/building rubbish malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of engineer-in-charge. note- item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 12 dewatering using 10hp to 70hp diesel engine pump set including hire charges, cost of diesel, engine oil, pump operator, labor charges, conveyance of pump set and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (hire charges for diesel pump set for 10 hp) 13 [b] bill no. 2 - earthworks 14 excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and leading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location within all lifts and lead upto 1000m 15 removal of unserviceable soil including excavation loading and disposal but excluding replacement by suitable soil which shall be paid separately as per clause 305 16 i) lead upto 1000 m 17 ii) lead upto 8000 m 18 earth work in excavation of foundation of structures as per drawing and technical specification, including setting out construction of shoring and bracing, removal of stumps and other deleterious matter dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for road work. 19 mechanical means (depth upto 1.5 m) 20 i) excavation 21 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 22 [c] bill no. 3 - development of carriageway 23 stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with irc-sp-72-2015 , irc-37-2012 & 2018 and irc sp 89 (part ii) 2018. cementitious additive @ rate of minimum 5 - 7% and ccs/cs additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. the additive spreader shall have variable working width sufficient to cover whole pavement lane. the in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. the resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per irc 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. the entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. the tandem roller be followed by pneumatic tyre roller. the minimum unconfined compressive strength (ucs) of stabilized sub base/ base should be 4.5 to 7 mpa after 7 / 28 days of curing as per irc-sp- 72-2015 , irc-37-2012 & 2018 . also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the gradation mixes and materials should be as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the train of equipments to be used are binder spreader- water tanker- additive truck- recycler- padfoot roller (20 tonne) + single drum compactor- grader- tandom roller- pneumatic tyreroller (20 tonne) 24 sami layerproviding and laying stress absorbing membrane interlayer (sami)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of claues 703-3, laid over a tack coat of paving grade bitumen 80- 100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement surface. 25 providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (tack coat on bituminous surfaces ) 26 providing and laying 40mmthickbitumencarpete(b.c.) with 100-120 tph hot mix plant producing and average output of 75 tonege par hour using crushed aggregates of specified grading premixed with bitumen binder(vg-30) @ 5.40% of mix as per most specification clause. etc all comp of work. 27 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from aggregat aggregate natural sources, portland pozzolana/ordinary portland/portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall. be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 28 m.s. (tor steel or plain) in plain work such as rcc or rb work including binding for proper shape and including supply of steel and its wastage bend, hooks and authorized overlapping shall be measured and including cost of binding wire. excluding gst (sor-504). 29 [d] bill no. 4 - pedestrian infrastructure (footpath) 30 sand filling in foundation trenches as per drawing & technical specification and as per direction of engineer-in-charge. (including beneath all paver blocks, cobble areas for levelling purpose, etc.) 31 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. (pcc below all paving area, kerb channel, road edge kerb, table top, property edge beam) 32 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 33 i) for grading-i material 34 plain/reinforced cement concrete in open foundation complete as per drawing and technical specifications, pcc grade m30using batching plant transit mixer & manual placing(80 mm thickness) r & manual placingand giving broom finish. (pcc with broom finish thickness 80 mm) 35 providing and laying 75mm thick m-30 grade batch mix cement concrete and applying stamping finish to the top surface of freshly laid plain/ reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the engineer-in-charge. the process shall include the following:-the concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. the approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. the approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. these stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the hole surface to be stamped is completed within the time while concrete is in plastic stage of setting.after stamping, the curing shall be done as per manufactures specifications. after initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per theequirement. the surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.the construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (pu) polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (cost of concrete for flooring is not included in this item which shall be paid separately.) 36 80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 37 supply and fixing of tactile indicators made from ss-304 grade stainless steel. warning tactile indicator shall be installed on the walking surface in a raised grid pattern of dots or stud. minimum 36 studs to be placed in 300x300 mm area. dimensions - 35mm outer dia x25mm inner dia, stem dia 8mmx12mm, weight - 28grm.all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property, all complete as per direction of engineer-in-charge. 38 supply & fixing of tactile indicators made from ss-304 grade stainless steel. directorial tactile indicator shall be installed on walking surface, consisting of a series of raised bar/strip. min 4 bars/strip to be placed in direction perpendicular to distance of travel in 300x300 mm area. dimensions-280mm l x 35mm w x 4.5mm, stem dia 8mmx12mm, weight - 250grm all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property., all complete as per direction of engineer-in-charge. 39 providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to is : 15622 of approved make in all colors and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer-in-charge 40 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (dsr-11.20) 41 providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of engineer-in-charge. (saucer drain along the road edge, curved kerbs at property entry/exit, curved kerbs at side roads) 42 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 43 cc grade m20 using batching plant transit mixer & manual placing all complete as per direction of e-i-c. 44 [e] bill no. 5 -parking 45 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 46 i) for grading-i material 47 supplying and filling in plinth with sand under floors/in trenches, including watering, ramming, consolidating and dressing all complete with material (from source to site), labor and t&p etc. required for proper completion of the work. (including royalty). 48 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days and giving broom finish. (pcc) 49 providing and laying factory made chamfered edge cement concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using pu mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of engineer-in-charge.80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 50 [f] bill no. 6 -cycle track 51 nil 52 [g] bill no. 7 - traffic signs, markings and other road appurtenances 53 providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow ms tube posts/horizontal members/bracings covered with 1.63mm thick ms sheet. the sheet shall be fixed with 30x5mm ms flat by suitable welding/riveting. the panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. ms channel islc 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long ms angle 40x40x6mm bracing. suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. the work shall be executed as per drawing/direction of engineer-in-charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the engineer-in-charge. the barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of engineer[1]in-charge.(note :- one time payment shall be made for providing barricading from start of work till completion of work i/c shifting. the barricading provided shall remain to be the property of the contractor on completion of the work). 54 reflective raised pavement markers (cat eye/ road stud) supply and fixing of raised pavement marker with made of plastic body of rpm/ road stud shall be moulded from asa (acrylic styrene acrylonitrile) or hips (high-impact polystyrene) or acrylonitrile butadiene styrene (abs) or any other suitable material approved by the engineer. the marker shall support a load of 13,635 kg tested in accordance with astm d4260. the reflective panels shall consist, of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face. lenses shall be moulded of methyl methacrylate conforming to astm d788 of equivalent. the slop or retro-reflecting surface shall preferably ba 5+/.5 degree lo base and the area of each retro -reflecting surface shall not be less than 13.00 $q.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & width shall not exceed 130 mm the base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. the contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the engineer . in addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. in case the markers are, displaced , damaged . get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the engineer , at his own cost. the rate shall include all materials, labor, t&p, transportation, installation and incidentals all complete as per direction of the engineer-in-charge, 55 rpm with shank 56 solar power road marker the solar studs shall be made of aluminum alloy and polycarbonate material which shall be absolutely weather resistant and strong enough to support to load of 13,635 kg tested in accordance with astm d4280. its color may be white, red, yellow, green or blue or combination as directed by the engineer. its water resistance shall meet the requirements of ip 65 in accordance with is: 12063:1987 category 2 for the protection against water ingress. the dimensions of solar studs shall not be less than 100 mm * 100 mm * 10 mm. it shall have super bright leds so as the provide long visibility from a distance of more than 800 m. its flashing rate shall not be less than 1 hz. its should be able to give the prescribed performance in the temperature range of -40 degree c to +55 degree c. its life shall be not less than 3 years. the rate shall include all material, labor, equipments, fabrication, transportation erection, installation and incidentals all complete as per direction of the engineer-in-charge 57 r.cc work (1:1.5:3) (m-20) with cement course sand &20mm the stone grit including all complete cement concrete with cement sand &20mm gauge stone grit with the proportion of (1:1.5:3)including all complete the work (morth ra-12.8 c, case-ii) 58 m.s. or iron work plain or tor for rcc work including cutting, bending, rivetting or welding etc. where necessary. excluding gst (s.i.no-504) 59 painting two coats on new concrete surfaces - painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 60 m.s. or iron work of heavy sizes section such as trusses, built up gates, record racks, roof work, gates etc. including rivetting or welding where necessary. excluding gst (s.i.no-503) 61 painting of m.s. grill with enamul paint etc all complete work. (s.i. 15.15 new item no.) 62 providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 63 providing and fixing of retro- reflectorized cautionary, mandatory and informatory sign as per irc :67 made of high intensity grade sheeting type-ivvide clause 801.3, 2mm thick aluminum sheeting, 1.5 mm thick supported on mild steel angle iron post 75mm* 75mm *6mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45cm* 45cm*60 cm, 60 cm below ground level as per the approved drawing. the retroreflective sheeting shall be tested for a certificate of having the sheeting coefficient of retro reflection, daytime, color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoors weathering and its having passed these tests shall be obtained from international/ government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should be also obtained from indian condition within 3 years of launching ofproduct by the manufacturing abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirement from a reputed laboratory in india can be accepted provisionally. in such a situation , the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per irc 67:2012 . legends, letters, numerals, and borders etc. should be as per mort&h specification 801.3.7. proof of the same in form of government reports shall be uploaded while quoting tender. 64 90 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 65 60 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 66 60 cm circular with diffinitation plate size (20cm x 60 cm) 67 80mm x 60mm rectangularwith diffinitation plate size (20cm x 60 cm) 68 60 mm x 45 mm rectangularwith diffinitationplate size (20cm x 60 cm) 69 60cm x 60cm square with diffinitation plate size (20cm x 60 cm) 70 90 cm high octagon 71 direction and place identification signs up to 0.90 sqm size board providing and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/ client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area not exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60cm., below ground level as per approved drawing, complete. 72 direction and place identification signs with size more than 0.90 sqm size boardproviding and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility. liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing, complete. 73 providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per irc :67 74 brick masonry work in cement mortar 1:4 (1cement: 4 coarse sand) in foundation complete with cement concrete bricks procured from c&d waste recycling plant baswar excluding pointing and plastering, as per drawing and technical specifications. 75 struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 finerness modulus.sor 2022 si no574 76 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 sand)and as per direction of engineer in charge. 77 finishing walls with ready mixed premium acrylic emulsion paint (company depot tinted) having volatile organic compound (voc)less than 50 gm/liter and uv resistance as per is 15489:2004, alkali, & fungal resistance, dirt resistance exterior paint of required shade with silicon additive(for painting wall, street furniture) new work (two or more coats applied @1.43 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm) 78 supplying and fixing of cast iron antique style bench having weight of sides not less than 72 kg (36 kg each) fitted with fibre rectangle strip (should not be less than 50 mm x 25 mm and 1.6mm thick. length of bench should not be less than 6 ft (end to end of castiron support). 79 [h] bill no. 8 - utility and street light cabling 80 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(pcc below pipe of storm water, sewer, water, inspection chamber for storm water, telecom chamber, power chamber and sewer) 81 providing and laying non pressure np-3 class (medium duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (storm water, sewer) 82 600 mm dia rcc pipes 83 providing of 7- way 40mm multi ducts with solid permanently solidly lubricated silicone in inner layer for ict fiber cables conforming to astm f 2160, astm d 2444 and /or equivalent indian standard. external sheathshall be in orange colorand shall be free from visual defects like blisters, shrink holes,flaking, scratches, groove lines & surface roughness. the color of the 7 nos. plb hdpe ducts shall be green, blue, yellow, brown, violet, grey , red for differentiation. outer sheet thicknessshall be 1.2mm +/-0.2mm. the inner surface of the multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. wall thickness(mm) of each of the ducts excluding rib height shall be 2.9mm +/- 0.3mm. iso requirements- iso 9001, 14001, 18001, complete as per specifications and directions of engineer-in-charge. (7 way multi utility duct for ofc) 84 supply of hdpe pipe of size 110mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.110mm dia hdpe pipe pn-6 class pe-100 85 supply of hdpe pipe of size 63mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.63mm dia hdpe pipe pn-6 class pe-100 86 rcc grade m20 using batching plant transit mixer & manual placing ( side wall, bottom slab for all inspection chamber i.e. storm water, telecom, power, sewer, water) 87 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class b125 having minimum load capacity 125 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. 88 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class d400 having minimum load capacity 400 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. (storm water) 89 supply and fixing gully grates red 048 grh – 300* 750mm d.i. gully grate & frame in d400 load class , as per bs en 124 black bitumen paint, all complete as per direction of engineer-in-charge. 90 constructing rcc rectangular type manholewith a floating coat of neat cement, foundation concrete 1:6:12mix (1 cement : 6 coarse sand : 12 graded brick bats 40 mm nominal size), and making necessary channel in cement concrete of m-25 grade finished with a floating coat of neat cement, all complete as per standard design and instruction of e-i-c. 91 restoration of water pipeline in case of damage 92 [i] bill no. 9 - horticulture / landscaping works 93 trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 94 supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 95 supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 96 mixing earth and manure in specified proportion or as directed. 97 rough dressing the trenched ground including breaking the clods. 98 fine dressing the ground 99 spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 100 uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 101 providing & laying selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 102 preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of officer-in-charge. 103 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 104 providing and stacking of nauclea cadamba (kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 105 providing and stacking of nyctanthes arbor-tristis (hasingar) of ht. 90-105 cm in earthen pots of size 20 cm as per direction of the officer-in-charge. 106 providing and stacking of terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 107 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 108 providing and stacking of plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 109 providing and stacking of ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 110 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 111 providing and stacking of duranta golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge.. 112 providing and stacking of tradescantia zebrina having in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 113 providing and stacking of wedelia trilobata,full of leaves in 15 cm size ofpoly bags & as per direction of the officer-in-charge. 114 providing and stacking of asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of earthen pot / plastic pot & as per direction of the officer-in-charge.. 115 providing and stacking of ophiopogon jaburan ( variegated ), full of variegated leaves in earthen pot/plastic pot of size 20 cm. as per direction of the officer-in-charge. 116 providing and displaying of croton petra bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 117 providing and fixing ms iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 nos (25 x 6 mm) and 8 nos (25 x 3 mm) vertical ms riveted to 3 nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of priming, complete in all respects. 118 street light works (excluding gst) 119 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 mtr length) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p complete in all respect 120 supply and fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. confirming to ip 66 protection complete in all respect. cat: aaa 121 supply and laying of 16 sq.mm. 4 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 122 supplying and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 123 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 124 making connection of each street light by s/l 1.5 sqmm frlsh copper wire complete as per direction of engineer in charge. 125 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with double arm bracket (1 mtr length each ) on rcc foundationincluding the cost of foundation, foundation bolts, excavation & back filling and required t&p completee in all respect. 126 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 127 supply and fixing for automatic street light cubical control juction box painted with anti-corrosive alkali and acid proof pait consisting of 6 amps mcb (b - curve) complete in all respect 128 supply and fixing of 16 sq.mm plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 129 supply and fixing of 40 amp. capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 130 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. 131 supply/ erection of surface mounted decorative pole 4500 mm long having base plate 300x300x12 mm with the bottom dia 139 mm upto 1 mtr long with the thickness of 3.6 mm and the top dia is 76 mm upto 3.5 mtr. log. decorative pole made out of galvanized iron tube with cast aluminium embellishments. the poles are painted with polyturetnane paint. the pole have service window at the bottom on the pole for housing the mcb and terminal strips and as per attached drawings. 132 s/f of single arm decorative bracket 100 mm long made of cast iron/ aluminium embellishments painted with polyturetnane paint. 133 supply of led decorative drop down light made of aluminium housing fitted with polycarbonate diffuser having 500 mm dia with 70 w. 134 supplyandlayingof aluminiumconductorpvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 135 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 40 a tpn 136 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 16 sq. mm 137 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 138 supply and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 139 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 140 part - b utility shifting (including gst) 141 converstion of lt overhead line by underground lt line 142 lt xlpe insulated cable of size 3.5x400 sqmm. 143 lt xlpe insulated cable of size 3.5x240 sqmm. 144 lt xlpe insulated cable of size 3.5x150 sqmm. 145 lt xlpe insulated cable of size 3.5x70 sqmm. 146 9 mtr long stp 147 hdpe pipe 140mm dia peb0, pn-6 148 hdpe pipe 120 mm dia peb0, pn-6 149 hdpe pipe 75 mm dia p880, pn-6 150 aluminium crimping lugs 400sqmm 151 aluminium crimping lugs 240sqmm 152 aluminium crimping lugs 150sqmm 153 aluminium crimping lugs 70sqmm 154 6 swg g.l. wire for earthing along cables. 155 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x400 sqmm. lt cable 156 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x240 sqmm. lt cable 157 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x150 sqmm. lt cable 158 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x70 sqmm. lt cable 159 main lt panel at sub station- 400 kva (type a-2)lncomer- 1 set of 800 amp. tp mccb with spreader & extended handlemetering on lncomer - 1 set of digital ammeter with ass- 1 set of digatal voltmeter with vss- 1 set of led type phase lndicating light (22.5 mm.)with control mcbsoutgoing- 6 set of 250 amp. tp mccb with spreader & extended handte( 5 nos. + 1 no. for capacitor panel)- 2 set of 100 amp. tp mccb with spreader & extended handle 160 main lt panel at sub statton- 250 kva (type a-2) lncomer- 1 no. 630 amp. tp mdo acb with inbuilt mpr release with i ontoff tnai.ating lightmetering on lncomer - 1 set of digital ammeter with ass- i set oldigital volt-meler wirh vss- 1 set of led type phase indicating light (22.5 mm.j with control mcbs outgoing - 5 set of 250 amp. tp mccb with spreader & exrended handle- 2 set of 100 amp. tp mccb with spreader & extended handle flnstallation oflt distribution boards for lt underground system (type a,b&cj) 161 supply , installation, testing & commissioning of outdoor type feeder pillar panetto be made of 2 mm crca sheet and covers will be j.6mm crca sheet dulypowder coated paint with 300 amps al. busbar. (type-b2)lncomer - 250 amp. tp mccb - 1 no.outgoing - 63 amp. tp mccb - 5 nos.lnstallation of lt distribution boards forlt underground system (type-a, b & c) 162 outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. [type-b3] incomer - 100 amp. tp mccb - 1 no. outgoing - 63 amp. tp mccb - 4 nos.lnstallation of lt distribution boards for lt qnderground system [tvpe-a, b & cl 163 lockable distribution boxes of size 450x400mm with bus bar 100 amp. tpn to feed upto 10 houses (type c) 164 xlpe lt service armoured cable for single phase,2x6 sq. mm.(pvc armoured consumer service cablel 165 xlpe lt service armoured cable for single phase,2x10 sq. mm.(pvc armoured consumer service cablej 166 xlpe lt service armoured cable for three phase,4x10 sq. mm.[pvc armoured consumer service cablel 167 xlpe lt service armoured cable for three phase,4x1.6 sq. mm.(pvc armoured consumer service cablel 168 xlpe lt service armoured cable for three phase,4x25 sq. mm.(pvc armou[ed consumer service cable) 169 pvc pipe 32 mm dia 170 pvc pipe 50 mm dia 171 electronic kwh meter 1px2w with box. for single phase consumer 172 electronic kwh meter 3px4w static meter with box.for three phase consumer 173 carriage , laying of 3.5cx400 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 140 mm dia. 174 carriage, laying of 3.5cx150/240 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 1.20 mm dia. 175 carriage ,laying of 3.5cx70 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 75mm dia. 176 painting of stp incuding paints [2 ltr red oxide and 2 ltr alluminum paint for each pole.l 177 grouting of st pole 178 cartage , erection and dismentling charges 22% of materials cost 179 conversion of 11kv overhead/underground line by 11kv line underground 180 11 kv cable size 3x185 sq.mm xlpe 181 stp 11m-is 410 sp-55 182 g.l pipe 4 dia 183 top channel 100x50x2240 mm 184 hdpe pipe 160 mm dia pe 80, pn-6 185 service clamp o/s 186 clamp for fixing pipe to pole 187 11 kv cable jointing kit size 3x185 sq.mm xlpe o/d 188 11 kv cable jointing kit size 3x185 sq.mm xlpe s/t 189 earthing complete. 190 m.s. nut & bolt with washer 191 bracing angle 65x65x6x2700 mm with clamp 192 stone pad 193 number plates with clamp 194 danger board & clamp with bolts & nuts 195 stay complete 196 g i barbed wire 197 carriage , layrng of 3x185 sq.mm size 11 kv xlpe insulated cable underground in hdpe pipe dia 160 mm. 198 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 199 grouting of st pole 200 grouting of stay set 201 cartage , erection and dismentling charges 22% of materials cost 202 conversion of 33kv overhead/ underground line by 33kv line underground 203 cable al. 3x300 sq.mm. xlpe 33 kv 204 stp 11m-is 410 sp-55 205 g.l pipe 6 dia 206 m.s.top channel 100x50x2240 mm 207 hdpe pipe 200 mm dia pe 80, pn-6 208 service clamp o/s 209 clamp for fixing pipe to pole 210 bracing angle 65x65x6x4300 mm with clamp 211 33 kv cable jointing kit 3x300 se mm outdoor 212 33 kv cable jointing kit 3x300 se mm straight through 213 earthing of pole by ms earthing rod of 2ox25o0 mm & 6 swg earthr.ng wire etc. 214 m.s. nut & bolt with washer 215 number plates with clamp 216 danger board & clamp with bolts & nuts 217 stay complete (stay rod 15x1800mm, stay wire 5 kg,, stay clamp, boult & nut rvith grouting 218 daner bqard barbed wire includin jumpering 219 carriage , layrng of 3x300 sq.mm size 33 kv xlpe insulated cable underground in hdpe pipe dia 200 mm. 220 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 221 grouting of st pole 222 grouting of stay set 223 cartage , erection and dismentling charges 22% of materials cost 224 installation of 250 kva transformer on dp for the shifting of 3 no. 250 kva. 9 no.400 kva & 3 no. 630 kva transformer 225 stp 11m-is 410 sp-55 226 ms channel 100x50x2240 mm 227 service clamp for round pole 228 m.s. bolt and nuts off size with washer 229 l.t. cable 3.5ox4oo so m 230 ltxlpe insulated,unarmoured aluminium singlc corc cable,1x240sq. mm.sizc 231 lt xlpe insulatcd,unarmoured aluminium singlc core cablc,1x400 sq. mm.size 232 earthing of 250 kva t/f with g.i. pip[ 233 earthing rod complet. 234 1 1 kv d.o. fi]se sets 235 1 1 kv tpmo 236 d.d. wire 70 qs mm 237 250 kva t/f 238 l.t. cubical b0x complete 239 l,t. cable 3.50x240 sq mm 240 stay set complete, 241 aluminimum lug 70 sqmm 242 aluminimum lug 240 sqmm 243 aluminimum lug 400 sqmm 244 pvc tape 245 t/f bushing connector of copper strip 246 labour , cartage & errection charges and dismentaling of existing t/f 247 dismentling and cartage from site to store charges 7% (other misclenous charges)
  • View Tender
  • Document
  • Bid Support
7 Telecommunication Services And Equipments
image image
Central Government And Public Sector
TRN :49019302 |  01 Jan, 0001
Tender Value : 0
 Patna - Bihar
Tender for corrigendum tender for water proofing treatment of terrace of ab block of 38 /40 harding road, patna. call.
  • View Tender
  • Document
  • Bid Support
8 Civil Work
image image
State Government
TRN :49019483 |  15 May, 2025
Tender Value : 22.50 Lacs
 Vikravandi - Tamil Nadu
Tender for tender for providing3 nos of work vikravandi block; 1 construction ofdrama stage at vishwareddipalayam in madhurapakkam panchayat 2 earth work excavation for foundation in all classes of soils and sub soil to full depthexcept in hard rock requiring blasting but inclusive of shoring struttingif required forthe sides of foundation. 3 0-0.30m 4 cement concrete 1:4:8 mix using 40 mm hbg metal for foundaion including watering wherever necessary and laid in layers of not more than 15cm thick. compacting etc., complete complying with standard specifications and as directed. 5 supplying and filling inbasement with gravel in layers not more than 15 cm thick , well ramed and consolidated complying with standard specification 6 supplying and filling in foundation and basement with good sand in layers not more 15 cm thick including ramming, watering and compacting etc.complete complying to standard specification 7 supplying and erection centering for sides and soffiots including necessaary supports and strutting as directed by the departmental officers. rate for 10m2 for the following items (rcc floor slab, roff slab, rectangular / square, tee/ ell beams, lintels, 8 below 9 supplying and fabricating and placing in position ms steel or ribbed tor steel for all reinforced cement concrete works as per the design given including cost of steel and blinding wire all floors etc., complete complying with standard specification. 10 reinforced cement concrete 1: 1.5 : 3 mix using20 mm iss hbg metal including cost and conveyance of all materials to site and all labour charges for mixing, laying and curing etc completefor 10 cum. 11 brick work in cm 1:5 mix using country bricks ground moulded of size 23 x 11 x 7 cm for the following including curing etc., complete complying with standard specifications. 12 finishing the top of roof with one course of pressed tiles of size 23 cm x 23 cm x 2 cm laid incement mortor 1 : 3 mix and pointingwith the same mortor mixed with water proof compoundincluding cost conveyance of all materials and labour charges etc complete 13 plastering with cm 1:5, 12mm thick over the cement concrete for floor finish including curing etc., complete complying with standard specifications and as directed by the departmental officers. 14 ceiling plastering with cement mortar 1:3 mixto 10 mm thick for r.c.c. items including cost and conveyance of all materials to site and all labour charges etc complete 15 granolithic flooring using 10 - 12mm chips including cost and conveyance of all materials to site and all labour charges etc complete 16 white washing 17 distembering two coats with primer coat and two coat with oil bound distember over cement plastered surface including all charges etc complete 18 painting two coats with approved exterior emulsion over the plastered surface over one coat of cement paint including cost of all materials and labour charges etc complete 19 electrification 20 provision for citizen informationboard 21 provision for photo 22 providingbore well and motor accessories an pumping main line atnear sudukattu padhai in v.pagandaipanchayat 23 bore well 24 charges for conducting geo physical survey 25 drilling of borewells anywhere in tamilnadu including transportation from one place to another with in tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. by first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( site will be shown by the twad board officers) including construction of mud pit.0m to 60m depth 26 reaming of 150mm dia borewell to 300mm dia borewell as directed at site 27 labour charges for inserting casing pipe supply& packing of pebbles 28 supply & delivery of 150mm dia pvc plain casing pipe as per is 12818 / 2010 29 supply & delivery of 150mm dia pvc slotted casing pipe as per is 12818 / 2010 30 charges for developing the borewell using air compressor in hours 31 supply, delivery and erection of submersible pumpset of50 lpmx 175 head as per sor twad - page 88 32 supply and delivery of ms kisok 33 supply and delivery of 3 phase panel board d.o.l with two level guard and auto start confirming to is specification for 5 hp pumpset.twad sor page 101 34 supply, delivery of 1.1 kv grade,pvc insulated and sheathed3 core flat copper submersible cable with isi marking conforming of is 694/1990 of reputed make for submersible motor erected in borewell. 35 50mm upvc column pipe 36 50mm gi flangeset heavy page 29 37 40mm ms clampset heavy page 29 38 50mm gm non return valve page 30 39 50 x 40mm gi reducer heavy page 26 40 63mx50mmpvc t.coupler page 10 41 40mm ball valve/ gm gate valve page 30 42 (i) aerial fuse board of size 15 x 10 x 6cmwith 32 a aerial fuse carrier(3 nos.) 43 (iii)wall mounting type ms cubical eb meter box with fuse carrier (3 nos) of 32 a capacity at eb supply point.this box is also to accommodate tneb energy meter with proper ventilation as approved by tneb. 44 (ii) supply and laying of 7/20 size pvc insulator copper conductor cable from aerial fuse to eb supply point etc., complete as per i.e rules. 45 25mm dia gi pipe for service point 46 25mm dia gi elbow 47 no.8 gi wire for earth(twin earthing) 48 stay wire 7/20 49 20mm gi pipe for twin earthing and cable encasing 50 4way nutral link 51 tw banel board (41 x 31 x 6cm) 52 labour charges for erection of submersible pump set including fixing and jointing the submersible cable with clamps to the required depth, valves and errection panel board control room twin earthing as per i.e rules including cost of civil works 53 supply,delivery, laying and jointing of 90mm od pvc 6ksc pipe inlcuding earth work excavation in all strata soil, refilling and hydraulic testing, adopting standard specification and as directed by twad board officer. 54 a.90mm pvc bend 55 b 90mm pvc threaded coupler 56 name boardand photo charge 57 construction ofdrama stagein kuthampoondipanchayat 58 earth work excavation for foundation in all classes of soils and sub soil to full depthexcept in hard rock requiring blasting but inclusive of shoring struttingif required forthe sides of foundation. 59 0-0.30m 60 cement concrete 1:4:8 mix using 40 mm hbg metal for foundaion including watering wherever necessary and laid in layers of not more than 15cm thick. compacting etc., complete complying with standard specifications and as directed. 61 supplying and filling inbasement with gravel in layers not more than 15 cm thick , well ramed and consolidated complying with standard specification 62 supplying and filling in foundation and basement with good sand in layers not more 15 cm thick including ramming, watering and compacting etc.complete complying to standard specification 63 supplying and erection centering for sides and soffiots including necessaary supports and strutting as directed by the departmental officers. rate for 10m2 for the following items (rcc floor slab, roff slab, rectangular / square, tee/ ell beams, lintels, 64 below 65 supplying and fabricating and placing in position ms steel or ribbed tor steel for all reinforced cement concrete works as per the design given including cost of steel and blinding wire all floors etc., complete complying with standard specification. 66 reinforced cement concrete 1: 1.5 : 3 mix using20 mm iss hbg metal including cost and conveyance of all materials to site and all labour charges for mixing, laying and curing etc completefor 10 cum. 67 brick work in cm 1:5 mix using country bricks ground moulded of size 23 x 11 x 7 cm for the following including curing etc., complete complying with standard specifications. 68 finishing the top of roof with one course of pressed tiles of size 23 cm x 23 cm x 2 cm laid incement mortor 1 : 3 mix and pointingwith the same mortor mixed with water proof compoundincluding cost conveyance of all materials and labour charges etc complete 69 plastering with cm 1:5, 12mm thick over the cement concrete for floor finish including curing etc., complete complying with standard specifications and as directed by the departmental officers. 70 ceiling plastering with cement mortar 1:3 mixto 10 mm thick for r.c.c. items including cost and conveyance of all materials to site and all labour charges etc complete 71 granolithic flooring using 10 - 12mm chips including cost and conveyance of all materials to site and all labour charges etc complete 72 white washing 73 distembering two coats with primer coat and two coat with oil bound distember over cement plastered surface including all charges etc complete 74 painting two coats with approved exterior emulsion over the plastered surface over one coat of cement paint including cost of all materials and labour charges etc complete 75 electrification 76 new door 77 provision for citizen informationboard 78 provision for photo 79 gst amount for providing service to government contract works for the above construction works. { gst amount is the total gst amount for total overall quoted amount above this row in column bb for all works in this package}
  • View Tender
  • Document
  • Bid Support
9 Telecommunication Services And Equipments
image image
Central Government And Public Sector
TRN :49019613 |  01 Jan, 0001
Tender Value : 4.94 Lacs
 Ahmedabad - Gujarat
Tender for tender for structural repair to left & back side external face of technical block portion, providing app water proofing treatment on terrace of technical block & lift room and allied civil repair works in t.e. bldg. bhadra, ahmedabad. (sh : app water proofing treatment on terrace of technical block & lift room
  • View Tender
  • Document
  • Bid Support
10 Construction
image image
State Government
TRN :49019760 |  13 May, 2025
Tender Value : 0
 Kanpur - Uttar Pradesh
Tender for tender for pd campus colony - dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. dsr -15.56 2 12 mm cement plaster of mixwith 1:6 (1 cement: 6 coarse sand) dsr 13.4.2 on wall. 3 12 mm cement plaster of mixwith 1:4 (1 cement: 4 coarse sand) dsr 13.4.1 on celling. 4 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including isi marked stainless steel butt hinges with necessary screws.dsr-9.21.1 5 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. with second class teak wood beading 62x19 mm.dsr-9.51.1 6 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. completedsr - 13.88 7 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.dsr-13.80 8 finishing walls with water proofing cement paint of required shade .( old work one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of priming coat. ) dsr-13.109.1 9 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour .dsr-13.81 10 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : one or more coats on old workdsr-13.99.1 11 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. concealed work, including cutting chases and making good the walls etc.15 mm nominal dia pipes . dsr 18.8.1 12 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply and all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 25 mm nominal dia pipes . dsr 18.8.3 13 providing and fixing c.p. brass bib cock of pproved quality conforming to is:8931 : 15 mm nominal bore sor/dsr 18.49.1 14 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. white vitreous china wash basin size 630x450 mm with asingle 15 mm c.p. brass pillar tap dsr 17.7.2 15 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests dsr 17.1.2 16 brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to is: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) . with f.p.s.(non modular) bricks .dsr-6.4.2 17 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate dsr 11.3.1 18 providing and fixing p.v.c. low level flushing cistern with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete.10 litre capacity - white .dsr-17.18.1 19 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. dsr-18.48 20 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). dsr 4.1.8 21 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes.110 mm diameter dsr12.41.2 22 renewing glass panes, with putty and nails wherever necessary including racking out the old putty:float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) dsr14.5.1 23 cleaning of chocked sewer line by diesel running vehicle mountinghydraulic operated high pressure suction cum jetting sewer cleaningmachine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 psi for sewer line from 150 mm dia upto 300 mm dsr 14.77
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : ac sheet roof work
  • Polycarbonate Roof Tenders ,
  • Terrace Tenders ,
  • Roof Materials Tenders ,
  • Water Proofing Work Tenders ,
  • Pvc Ceiling Tenders ,
  • Steel Roof Tenders ,
  • Ac Sheet Roof Repair Tenders ,
  • Roof Framing Works Tenders ,
  • Roof Framing Tenders ,
  • Roof Tiling Tenders

Get ac sheet roof work Tender Alert...

043731

Related Searched Keywords : ac sheet roof work

  • Ceiling Tenders From Maharashtra
  • Paver Work Tenders From Delhi
  • Dismantle Tenders From West-Bengal
  • Ground Levelling Tenders From -Tamil-Nadu
  • Drainage Tenders From Andhra-Pradesh
  • Civil Engineering Service Tenders From Gujarat
  • Civil Infrastructure Work Tenders From Karnataka
  • Development Work Tenders From Uttar-Pradesh
  • Embankment Tenders From Rajasthan
  • Granite Work Tenders From Madhya-Pradesh

Read More


Tender Document

997012

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Wire Fence Tenders
  • Bridge Work Tenders
  • Civil Engineering Tenders
  • Culverts Tenders
  • Paver Work Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App