Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Acoustic Work
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of acoustic-work Tenders

List of latest acoustic-work Tenders in Indian Tenders. Click on any acoustic-work Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for acoustic-work Tenders.

Advance Search
  • All-Tenders (72)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Construction
image image
State Government
TRN :49051926 |  16 May, 2025
Tender Value : 30.36 Lacs
 Panaji - Goa
Tender for construction of hall and supplying gym items for pinto youth club of baradi in velim constituency under mla-lad scheme.--demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. 2 demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. 3 laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. 4 extra for laterite masonry in all sizes in superstructure from floor i level upto floor v level. 5 12mm cement plaster 1:4 (1 cement : 4 fine sand) 6 providing and fixing 1st quality ceramic glazed wall tiles (johnson somany kajaria ) conforming to is:15622 (thickness to be specified by the manufacture of approved make in all colours shades except burgundy bottle green black of any size as approved by engineer-in-charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.;wall ceramic glazed tiles : 300 x 600 7 providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of johnson somany kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to is: 15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc. complete;dark shades 8 proving and fixing white vitreous china wall hung type (european type) water closet with seat and lid with c.i. brass hinges and rubber fittings with flush valve nelson/ similar fully chromium plated with stop cock wall flanges flush pipe or elbow and vaccum breaker coupling etc. including chair bracket/rag bolts cutting & making good the walls and floors where required and concealed seat support - w.c. pan with white plastic seat and lid 9 providing and fixing brass stop cock (heavy) of approved quality :;15 mm nominal bore 10 providing and fixing brass full way valve (heavy) duty with wheel of approved quality :;20 mm nominal bore 11 providing and fixing p.v.c. connection pipe with brass unions 15 mm nominal bore:;45 cm (18”) length . 12 providing and fixing rigid pvc s.w.r. (soil waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:; 110 mm dia 13 providing and fixing rigid pvc bend (approved make) for s.w.r. pipes including lubricating etc complete bend with door :; 100 mm dia 14 providing and fixing nahani trap of rigid pvc (approved make ) for s.w.r. pipes including lubricating etc complete without door :;110 mm dia 15 providing and fixing nickel chrome plated copper alloy fancy bib cock short body jaquar make or equivalent.confirming to is 8931; 1993;15mm nominal bore 16 providing and fixing chlorinated ployvinyl chloride (cpvc) pipes confirming to is:15778 having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. this includes jointing of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of the engineer-in-charge. concealed work (medium duty sdr 13.5 pipe) including cutting chases and making good the walls etc.;20 mm dia nominal outer dia pipes. 17 providing and fixing hand shower (health faucet) with 8mm dia abs/brass body with double lock 1.00 m long flexible tube (brass plated stainles steel flexible hose) and wall hook of approved quality confirming to is standards. 18 frp (fiber reinforced polymer) frames with wood finish manufacture supply and installation (with anchor fastener) of epee or equivalent goan make frp (fiber reinforced polymer) frame of cross section as per options below with right angle joint and frp (fiber reinforced polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). the core of frame would be filled with seasoned wood as infill material. the slot of frame for door resting will be of suitable width so as to take specified thickness door.the frame will be water proof as well as mild acid/ alkali resistant manufactured in an iso 9001- 2015 certified company.;specified cross section;4” x 2” 19 wood finish wood core frp (fiber reinforced polymer) door shutter. manufacture supply and installation (including accessories as mentioned below) of epee or equivalent goan make frp (fiber reinforced polymer) door shutter of specified thickness as per options below by using tray system with seasoned hard wood moisture less than 17% wooden styles for top rail and lock rails. frp (fiber reinforced polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) and printed matt having wooden textures used along with uv resistant resin to give the clear texture on the door. the core of shutter will be filled with mr 2nd grade block board. the shutter to be water proof as well as mild acid / alkali resistant manufactured using rv tifac (r v engineering college bangalore & technology information forecasting & assessment council) technology in line with is 13034 1990 test standard in an iso 9001 – 2015certified factory. accessories: i) s. s. hinges 4” - 3 nos ii) s. s. latch - 1 no iii) tower bolt 5” - 2 nos iv) handle 5” - 2 nos;shutter thickness;32mm 20 providing and applying white cement based putty of average thickness 1.00 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. 21 applying one coat of cement primer of approved brand and manufacture on wall surface. 22 wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. 23 painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. 24 applying priming coat with ready mixed primer of approved brand and manufacture on steel work. 25 providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts nuts and wooden plugs and embeded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size.;40 x 3 mm flat iron hold fast 15 cm long 26 providing and fixing m.s. grill of required pattern in wooden frames of windows etc. with m.s. flats square or round bars with round headed bolts and nuts or by by screws.; plain grill 27 centering & shuttering including strutting propping & removal of forms for :;columns piers pillars aburments posts and struts (square rectangle polygon in plan) 28 centering & shuttering including strutting propping & removal of forms for :;sides and soffits of beams beam haunchings cantilever girders bressumers and lintels plinth beams not exceeding 1m in depth 29 centering & shuttering including strutting propping & removal of forms for :;suspended floors roofs landings shelves & their supports 30 providing and fixing 18 mm thick gang saw cut mirror polished premoulded and prepolished machine cut for kitchen platforms vanity counters window sills facias and similar locations of required size approved shade colour and texture laid over 20 mm thick base cement mortar 1: 4 (1 cement : 4 coarse sand) joints treated with white cement mixed with matching pigment epoxy touch ups including rubbing curing moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite of any colour and shade area of slab over0.50 sqm;jet black 31 providing and laying in position machine batched concrete (bmc) machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering shuttering finishing and reinforcement including admixtures in recommended proportions as per is 9103 to accelerate retard setting of concrete improve workability without impairing the strength and durability as per the direction of the engineer-in-charge. m25 grade of reinforced cement conrete by using 410kg of cement per cu.m. of concrete. all works upto floor v level. 32 providing tmt steel reinforcement bars of (sail tata. vizag jsw steel ltd.) ) (confirming to is 1786 of 1986) for rcc work (conforming to i.s. 1786 of 1986) including bending binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. 33 providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the engineer-in-charge: windows with three sliding shutters using 18 mm series shutters section.;plain glass 34 extra for powder coating with pure polyester powder of shade of required colour on the aluminium section 35 providing and fixing vitreous china wash basin with rs or c.i. brackets painted white 15 mm c.p. brass pillar taps c.p. brass chain with rubber plug 32 mm c.p. brass waste of pattern 32 mm diameter m.i. or c.p. brass trap and union complete including cutting and making good the walls where required.; flat back wash basin size 550 x 400mm with a single 15 mm c.p. brass pillar taps. 36 providing and laying in position cement concrete 1: 2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering shuttering and finishing :;all works upto plinth level 37 providing and fixing astm upvc pipe conforming to astm 2467 with iso 14001 including all upvc plain & brass threaded fittings including jointing of pipes & fittings with one step upvc solvent cement trenching refilling & testing of joints complete as per direction of engineer. external work.;sch-80(blue)/(w hite);40mm outer dia. 38 providing and fixing g.i. chain with g.i. pull. 39 providing woodwork in frames of doors windows clerestory windows trusses & other frames wrought framed and fixed in positon.;second class indian teak wood 40 providing and fixing 38 mm thick panelled glazed or panelled and glazed shutters for doors windows and clerestory window including black enamelled iron butt hinges with necessary screws:;second class indian teak wood 41 applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete. 42 painting two or more coats (excluding priming coat) with superior quality ready mixed paint for wood work of approved brand & manufacture in all shades on new work to give an even shade. 43 providing & fixing chromium plated brass tower bolts (barrel type) with necessary screws complete.;250 x 10 mm 44 providing and fixing chromium plated brass sliding door bolt with bolts nuts and screws etc. complete.;300 x 16 mm 45 provided and fixing 150 mm chromium plated brass floor door stopper with rubber cushion screws etc. to suit shutters thickness complete. 46 provided and fixing chromium plated brass 100mm. mortice latch and a pair of levers and handles with necessary screws etc. complete (indian make of approved quality). 47 providing and and laying vitrified floor tiles in different sizes of johnson somany kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigment etc. complete;600 x 600 mm light shades 48 false ceiling:-;providing & fixing false ceiling yashashri make or equivalent made out of 2” x 1” m.s sq tube frame support structure & 20mm x 155mm x 1.2mm multi- cavity upvc section 30mm x 40mm x 2mm upvc multi-cavity section with hidden screwing system.the average weight of false ceiling is 8.50 kg per sq mtr. these upvc sections are tested by using bs 2782 & din 53459 test methods. 49 providing & fixing of aluminium lay-in perforated tile ceiling on 24 /14 mm ‘t’ framework of module 600mm x 600mm. tiles of size 575mm x 575mm / 584mm x584mm made out of 0.6mm thick aluminium. perforation of the tiles shall be 2.5mm dia 5.5mm c/c. the tile shall be manufactured on advanced equipment which includes several levelling. the tile end shall be raised upward by 38mm and bend outward to lay the tile in framework. the tile shall be polyester based powder coated in white colour. grid system for fixing ceiling tiles shall comprise of tees. the 24 /14 mm main tee runners shall be suspended at an interval of 1200mm centre to centre. the 24 /14 mm cross tee runner shall be suspended at 600mm centre to centre and further supported with 24 /14 mm cross tee at 600mm centre to centre with interlocking arrangements to form grid of 600mm x 600mm. the main tee shall be supported by means of 4mm g.i. rod from slab/roof. the suspension shall be provided at 1200 to 1500mm centre to centre.tee framework would be made of gi and powder coated. acoustic felt: non- woven felt made of glass-r einforced fibre glued over the perforation for sound absorption. 50 providing water proofing treatment over the new r.c.c. roofs terrace toilet by spreading cement slurry over the r.c.c. slab and laying of 10cms. average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of hindustan water proofing co. or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand) finished smooth with wooden trowel with false marking of 30 cms square. the vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. the injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb cracks etc. in the r.c.c. slabs). note: cement consumption 25 kg/sq.m. 51 providing & fixing colour coated alluminium (puf) sandwich panel roofing systems of approved make adhering to aluminium 3105 grade for top & bottom sheet of thickness0.40 & 0.35 respectively including puf insulation betewwn the top & bottom sheet of denslity 40 (+/-2) kg/m3 inclusive of s.s. 304 grade self tapping fastneres complete as directed by enigneer incharge (frame work for roof roof accesorries to be paid seperately) for tile design puf roof panel gutter width should be atleast 25% more than the crest width. minimum height at heighest point of crest should be minimum 65mm. minimum thickness at anygiven point should not be below 30mm.;puf insulated tile roof 30mm thick of trapezoidal design 52 steel work in built up tubular (round square or rectangular hollow tubes etc.) (square hollow section (shs) is4923 /rectangular hollow section (rhs) is4923/circular hollow section (chs) is1161 closed structural steel of (sail tata. vizag jsw apollo steel ltd.) make (min yeild stress 310 mpa)) trusses etc. including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc. complete. 53 providing and fixing in position s.s. hand rail in main stair case and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials etc. complete. 54 melamine polishing on wood work (one or more coat);glossy 55 providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the engineer-in-charge: adjustable louvered window s.;figured glass 56 extra for powder coating with pure polyester powder of shade of required colour on the aluminium section 57 6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand) 58 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. 59 painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as dulex/ asian paints/ sherwin willians) including applying one coat of cement primer and one coat of surface treatment etc. complete. 60 painting one or more coats of acryllic exterior paint of approved brand and manuf acture(such as dulex/ asian paints/ sherwin willians) on old work including cleaning the surface with water etc. complete. 61 providing & fixing alluminium ridge of approved make adhering to alluminium 3105 grade of 0.71mm thickness & 60 cm wide inclusive of ss304 grade self tapping fastners to match the alluminium roofing system & as directed by engineer in charge complete 62 providing & fixing alluminium 30mm trapezhoidal end cap for puf roofing of approved make of alluminium aa 3105 grade matching with 30mm puf panel profile including the required fastners etc. complete for alluminium puf roofing system & as directed by engineer in charge. 63 pvc wall paneling : providing and fixing pvc sheet wall paneling of thickness 5mm (±0.25) consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm (±0.25) thick prelam pvc sheet.the panel & strips shall be of 600 kg/cbm density manufactured by an iso-9000 certified company. the strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two pvc strips. the pvc strips shall be fixed to the wall using 65mm long m.s. screws through the groove in the strip by using pvc fasteners. the distance between two screws shall not be more than 200mm. a groove of 2mm may be left at the joint of two panels for aesthetic looks. the exact size of the panel and correspondingly of the grid may vary depending on the size of the wall.optionally a strips of 5mm (±0.25) thick pvc sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined using solvent cement. 64 providing and installing rubber dumbells of hexagonal shape and approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 65 providing and installing barbell rod 5ft of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 66 providing and installing skipping rope of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 67 providing and installing yoga mat 6mm thick of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 68 providing and installing punching bag of 900mm diameter of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 69 providing and installing bench press multidegree of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 70 providing and installing rowing machine of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 71 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. a)2.50 kg 72 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. b) 5.00 kg 73 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. c) 7.50 kg 74 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. d)10.00 kg 75 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e)12.50 kg 76 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e) 15.00kg 77 providing and installing dumbell rack of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 78 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. a) 2.00 kg 79 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. b) 4.00 kg 80 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. c) 6.00 kg 81 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. d) 8.00 kg 82 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e) 10.00kg 83 providing and installing gym ball 65cms of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 84 providing and installing gym ball 75cms of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 85 providing and installing push up bar with chrome finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 86 providing and installing ab wheel roller finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 87 providing and installing foam roller finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 88 providing and installing air bike of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge.
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
3 Non Diversified
image image
State Government
TRN :49056450 |  02 Jun, 2025
Tender Value : 0
 Panchkula - Haryana
Tender for purchase of projection system, shows and associated items. , purchase of projection system, shows and associated items. (please enter rates as per annexure-g of dnit) , as per clause no.: 3.1: charges for total number of 2d 4k_uhd projectors being offered including cables, connectors and other accessories , as per clause no.: 3.1 (a)11: charges for total number of professional customized fish lenses being offered with accessories , as per clause no.: 3.1 (a)11: charges for complete physical masking setup system for projector output , as per clause no. 3.3: charges for complete computer hardware system to be used as operator & maintenance console, graphic handling includingoperating system, accessories, other applications etc. , as per clause no. 3.5: charges for full dome show player software (for single user license) , as per clause no. 3.5: charges for sky-simulation software (for single user license) , as per clause no. 3.2: charges forcomplete automatic blending and geometry correction unit , as per clause no. 4.5 : charges for staff training , as per clause no. 4.10 : charges for one additional pre-configured computer cpu ready for running shows , as per clause no. 4.10 : charges for one additional pre-configured projector with accessories ready for running shows , as per clause no. 4.6 : charges for pre-configured tablet-pc and associated components to be used as an portable operator’s interface , as per clause no. 4.8: charges for dome cleaning, replacement of exiting insulation sheets with acoustic sheets of poly-synth material and associated works , as per clause no. 4.2 : charges for complete led cove lighting system with dmx system with accessories , as per clause no. 4.3 : charges for complete 5.1 audio system with accessories , as per clause no : 3.9 and 4.4, if any modification/up-gradation is required in the existing electrical & civil infrastructure, then please mention such charges as per details submitted in the technical bid , as per scope of work: service charges for supply, installation, testing and commissioning of the whole system as per scope of work which includes projectors with calibration, alignment and physical masking , fish eye lenses, computer systems (hardware and software), led lighting and 5.1 audio systemetc. , as per clause no. 4.9 : year wise charges for onsite comprehensive annual maintenance contract (cmc) of the complete system along with additional computer and projector (after expiry of 5 years of purchase warranty) , 6th year , 7th year , 8th year , 9th year , 10th year
  • View Tender
  • Document
  • Bid Support
4 Telecommunication Services And Equipments
image image
Central Government And Public Sector
TRN :49019190 |  14 May, 2025
Tender Value : 76.5 Thousand
 Madurai - Tamil Nadu
Tender for tender for sitc of 40 kva ea set with amf control panel with acoustic enclosure for te ambasamudram. (tvl ssa). sh : ea aux works 1. engine 2. alternator(brushless) 3. battery (lead acid/mntc. free) 4. hv switchgear (vacuum circuit breaker/sf6 ) 5. transformer (oil filled/dry type) a) above 400 kva b) up to 400 kva 6. air circuit breaker 7. mccb(ics=icu) 8. sdf units 9. power contactors 10. change over switch 11. intelligent apfc relay 12. bus bar trunking/sandwiched bus duct 13. power capacitors (mpp/app) 14. digital/kwhr meter 15. cold shrink ht/lt cable joint 16. rubber matting 17. mcb/ lsolator/elcb/rccb/distribution board 18. ms/ pvc conduit 19. cable tray 20. ht/lt cables 21. pvc insulated copper conductor wire 22. centrifugal pump 23. submersible pump 24. motors 25. fresh air fans 26. starter 27. single phase preventer 28. gi/ms pipe 29. foot valve 30. gate valve 31. compressors 32. resin bonded glass wool 33. expanded polystyrene 34. gauge 35. controls 36. fine filters 37. gi sheet 38. heat detector 39. ionization detector 40. photo electric smoke detector 41. fire panel (microprocessor based) 42. sprinkler/hose reel & hose pipe 43. fire extinguisher 44. lift
  • View Tender
  • Document
  • Bid Support
5 Construction
image image
State Government
TRN :49020462 |  15 May, 2025
Tender Value : 0
 Akola - Maharashtra
Tender for rate call for ( non dsr) items preparing estimate of under honble balasaheb thackeray haridra research and traning centre,vasmat,dist.hingoli =2 providing & fixing on site 75 mm thick reflexology ( pebbles ) stone flooring etc complete 3 providing & laying of hdpe pond liner of 750 micron thickness as per manufacturer’s specification & instructions from engineer in charge etc. complete. 4 orientation signage pole :- providing & fixing of orientation signage pole made up of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), with the size of 12x4inner frame and 60mm dia for support structure made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. the structure will be illuminated from within. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 5 identification signage pole :- providing & installation of identification signage pole made up of marine quality composite from 60mm dia for support structure {marine grade corrosion resistant & hydrocarbon solvent resistant) with all fittings fixture, hardwares , all as per design & drawings with all fittings, fixtures etc. complete , with the size of 6x1.5inner frame made of mild steel pipe od 60mm as the main support section is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 6 directional signage -5m single arm frp pole with haldi banner and leaf (signage): the single arm pole shall be made of 68 mm dia with metal hot dipped galvanized pipe support inside the frp cladded pole. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of is:3601 or equivalent, hotdip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted which usually require maintenance and care. pride suspended luminaire: 50 watt led suspended luminaire with height 450mm and width 500mm. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 7 directional signage post :-providing & fixing of directional signage post (signage) with 5ft height and 700mm wide post and 48 mm dia support pipe with frame having and metal frame to show the directional or location of certain area. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer incharge etc. complete on site. structural stability certificate will be givenv 8 haldi information post :- providing & fixing of haldi information post- farming (signage) with 5ft height and 700mm wide and 48 mm dia support pipe with frame having a metal frame work to be used for provided information regarding the harida haldi project and which type of haldi crop grown on the particular field. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. item is also including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete. 9 pergolas type 1:- providing & fixing of type 1 pergolas with frp column 200mm x 200 mm in ms fabrication use in 88.2 od ms pipe 3 mm thickness. frp beam size 150 mm x 150 mm in ms fabrication 40 mm x 40 mm x 2 mm thickenss tube in framing. frp support for beam and column use in 75 mm x 75 mm x2 mm ms tube with frp cladding. frp thickness minimum 3 to 4 mm . column fittng in 12 mm x 150 mm anchor bolt in foundation. including installation machineries, scaffoldings, electricity, other site utilities in client scope. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structure stability certificate will be provided etc complete 10 pergolas type 2( for seating areas ):- providing & fixing of type 2 with frp column 200mm x 200 mm in ms fabrication use in 88.2 od ms pipe 3 mm thickness . frp beam size 150 mm x 150 mm in ms fabrication 40 mm x 40 mm x 2 mm thickness tube in framing. frp support for beam and column use in 75 mm x 75 mm x2 mm ms tube with frp cladding. frp thickness minimum 3 to 4 mm . column fitting in 12 mm x 150 mm anchor bolt in foundation. including installation machineries, scaffoldings, electricity, other site utilities in client scope. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. type 2 (for seating areas ). item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structure stability certificate will be provided etc complete. 11 providing & fixing of type 01 module ( with back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made in combination of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 12 providing & fixing of type 02 module ( without back rest) frp seating with pvc wooden panel bench should be made in combination of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life . item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 13 providing & fixing of type 01 module ( with back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 14 providing & fixing of type 02 module ( without back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 15 dustbin frp dustbin should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant) all weather proof & maintenance free with long design life. the product should be 700 x 500 frp planter with basic design and 40 x 20mm sq. pipe to support the section of dustbin. it should be selfcolored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 to 4 mm average with sizes 2000x600 mm. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 16 providing & placing at position type1 of 700mm x 305mm frp plantershould be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should be 700 x 305 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage shall be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 17 providing & placing at position type2 of 610 mm x 254 mm frp planterfrp planter should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should 610 x 254 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 18 providing & placing at position type3 of 510 x 200 frp planter frp planter should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should 510 x 200 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 19 tree grating:- providing & fixing of frp tree grating of size 1100 x 1100 x 25 mm frp material with various design options. made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), the product should be an all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. as per design & drawings with all fittings, fixtures etc. complete. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site.. 20 custom design, supply & installation /surfacing of epdm 6 mm & 19 mm rubber crumbs at site etc complete 21 providing & fixing of tumble twin with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 22 providing & fixing of animal mgr with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 23 providing & fixing of deluxe junior see saw with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 24 providing & fixing double post swing with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site etc complete 25 providing & fixing duck rider with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 26 providing & fixing fun walker single with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 27 providing & fixing step trainer with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 28 providing & fixing chest press double with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 29 providing & fixing shoulder press double with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 30 providing & fixing tai chi cum standing twister with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 31 providing & fixing leg press cum parallel bar with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 32 providing & fixing leg press cum seating twister with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 33 providing & fixing of cobble stone of basalt 100 mm x 100 mm & 40 to 50mm thick etc complete 34 providing, fixing & installation of 18mm thick grc ( glass reinforcedconcrete ) of high quality iso grade upto 2.4 mtr height with 18mm grc chopped strands includingpure white cement , silica sand for finishingwith coating of sbr liquid or equivalent chemical for bonding work with all fittings, fixtures hardwares, wax polishing, caster, fitter, labour charges, scaffolding etc. complete as per design, drawings & manufacturer’s specification also as per instructions from engineer in charge etc. complete. sbr liquid will be used for bonding of various materials of the structure which also helps in waterproofing and adhesion giving it a long life durability specially multi dies will be made using cnc machine giving it a high precession for the design of the structure. material is made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant). its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life including structural stability certificationetc complete. 35 providing, fixing & installation of 4 mm thick frp ( fiber reinforced polymer) material high quality iso grade. frp material placed above grc of high quality iso grade material as per design, drawings & as per manufacturer’s specification & instructions from engineer in chargeincluding all hardener, fittings, fixtures, welder, patch work,labours charges, scaffolding etc. complete . the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life including structural stability certification etc complete. 36 providing & applying weather finish coating & lackering of 100microns to all surfaces of grc & frp with all rubbing, finishingwith all equipments, labours, scaffolding all as per design, specification & instructions from engineer in charge etc. complete 37 waterproofing cum insulation composite system:-cleaning the surface to make it dust free andsludge free, removing any extended portions by grinding and if required using suitable equipment’s and should be totally dry & have proper slope for free flow of water preparing the surface by spray applying a coat of bitumen primer @0.25-0.35kg/square metre over the entire dust free surface. providing and applying single layer of ultraplast b app- 4mm (atactic polypropylene polymer) modified water proofing membrane reinforced with non-woven polyester matt 160+20 g/m2 having polymer film as a top surface. minimum tensile strength in longitudinal and transverse direction as 750n +150 / 600n +120/5cm (astm d 5147). minimum nail shank tear resistance in longitudinal and transverse direction as 300/300n + 100 n (astm d 4073) elongation in longitudinal and transverse direction 40+8% / 45+9%. softening point of membrane not less than 150 + 5 degree celsius consisting of a coat of technonicol bitumen primer no 01 primer @ 0.25- 0.35 ltr./sq.mtr with a relative viscosity of 15-40 s,. over the primer coat, the layer of membrane shall be laid using butane / lpg torch and sealing all joints with minimum 75 mm side laps & 100 mm end laps to form a monolithic system. the laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane etc complete. 38 providing and laying leed certified carbon prof 300 extruded polystyrene 50mm thick having thermal conductivity of 0.028 w/mk (astm c 177) with compressive strength of > 300 kpa (astm d 1621 en 826) and density of 30-35 kg/m3. long term water immersion astm c 272 (en12087) < 0.7% over the waterproofing membrane having shiplap arrangement. work shall be done through the authorized applicator of the manufacturer of the insulation boardetc complete. 39 prviding & fixing glassreinforced concrete (grc)25mm jali as per deign & details etc completed. 40 providing and fixing heavy gauge galvinsed iron 50”fan with autoopening 10shutters, drop hamper exhaust fan systems with 6 no.ss blades with low noise , cfm:-25890, auto opening shutters damper type 415v,50hz, 1.5hp motor, 3hp with fitting etc complete.cellulose cooling pad 1200mmx600mmx100mmt one pad contain area of 1 0 sqft, leading kit with pipeline upto frame,- bypass, filter flush system etc.6”aluminum frame for the above coolingpads with top water distribution and bottom gutter, aluminum 41 providing & fixing air circulation fans 7 blades ss aluminum powder coated of model gtacf-40-70, size of d320mmxh400, 50hz , 1400 rpm, 220v, 120w, single phase, 70 ft airflow etccomplete. 42 automatictemp humidity controller- providing & fixing microprocessor based temp & humidity controller excluding moisture sensors, electrical control panel for fan,cooling pad, pump, mcb, contractor, olr, auto manual switching on/of fswitches ip55 cabinet, electrical cable 1 .5sqmm 4core for fans and pads,sensor cable 4core 0.5square mm etc complete. 43 providing & fixing controller - plc & hmi based control, drip valves control -2 nos,dosing valves control- 3nos ( a-b,c-acid), filling pump, system pump, air pump control, mixing valve control, phase missing prevention, over current prevention control, operation modes: auto -manual-bypass. 44 providing & fixing dosing unit includes dosing channels - 3nos @400lph with flow indicatiors & regulators, dosing valves - 3 nos (a-b,c-acid ), system pump - 30klph@35m head- ss 316 grade, dosing line filters-3nos 45 providing & fixing flow sensor of 3” as per design & drawing etc complete. 46 providing & fixing regenerative air blower-385cfm for 2 stocks mixing as per design & drawing etc complete. 47 providing & fixing solenoid valvesof 2” as per design & drawing etc complete. 48 providing & fixing exhaust fans -1.5hp 3phase- 16 nos4 controls ( each control 4 fans) pad pump - 3hp, 3phase- 1no fogging pump-5hp- 1no acf- 0.5hp- 1phase- 32nos - 1 control (3 phase load distribution) temperature sensor - 1no etc complete. 49 providing & fixing pressure release valves of 2” as per design & drawing etc complete. 50 providing & fixing total galvinsed iron structure of column pipes, profile, zig-zag spring, locking, perlins, tie bar, cross, gutter purlin, hockey , hockey memeber, hockey runner, nagarpatta, galvinsed gutter sheet, l, f brcackets, clamps, bolts , nuts, self drilling screw, spring, sliding pulley, netring, curtain clamps, door cup, handle, fiber door, hole pass. above all incudes, complete structure- erection, fixing etc complete. 51 poviding & fixingpoly film, 50% shade net, 30% side net with 6.5m center height,d rain out, israel make ginegar diffuse 200micron. above all incudes, making foundation, completestructure- erection, fixing etc complete. 52 providing & fixing high-tech irrigation system including inline drip lateral, inside main and sub main pvc pipes, fogger system, sand filter, disc-filter, ventury system with instillation & testing. 3024 sqm etc complete. 53 providing &fixingweed control mat 3000 sq mtr 120 gsm as per design & drawing etc completed. 54 providing &fixingplastic trough20:50:20500 micron 6000 running mtr etc complete. 55 providing & supplying low electrical conductivity coco-peat as instructed etc complete. 56 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 300mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 57 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 600mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 58 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 900mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 59 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 1200mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frameetc complete 60 supply, installation, testing, and commissioning of the electrical trench, with dimensions of 1300mm length, 1300mm width, and 1300mm depth, which includes a cover at every 15-meter interval, and also includes all necessary civil work to complete the electrical trenchetc complete 61 providing and fixing of ‘seamless gloss’ tiles of himalyan acoustics / baux / baswa or equivalent20mm thick with square edge made of gloss base panel (non-magnisite) with wood fibre 1mm width cement composites covered with acoustically transparent absorptive microfibers on the front side pasted on site with sprayable glue and colour as per the choice of the architect/ person in charge with seamless finish. has excellent noise absorption of 0.85 nrc as per iso: 354-1985 and astm 423-90 a, stc of 47 as per astm e90/413 for 25mm, density 400 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60o celcius(140o farenhite) for 15 days= no deterioration. conforms to en 131682001 and are rohs complaint and anti-bacterial test as per jis-z2801-2010.to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results( ceiling absorption nrc 0.85) etccomplete. 62 providing fibrette doodle 20 ceiling tiles of himalyan acoustics / baux / baswa or equivalent made of wood fibre cement composites with an option of colours as per the choice of the architect/ person in charge of size 1200 x 600 mm highly recommend for walls / ceilings. has excellent noise absorption of 1 nrc as per iso: 354-1985 and astm 423-90 a, density 400 kg/ m3, meets stringent fire ratings astmd-876 and fire class -1 and class p-not easily ignitable as per bs-476-part 5,6,7, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60° celsius (140° fahrenheit) for 15 days= no deterioration. tested as per en 131682001 and are rohs complaint. to be installed on g.i studs 600x600mm centre to centre2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life witha backing of himalyan acoustics 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results(ceiling absorption nrc 1 ) etc complete 63 providing and fixing of ‘seamless gloss’ tilesof himalyan acoustics / baux / baswa or equivalent wth 20 mm thick with square edge made of gloss base panel (non-magnisite) with wood fibre 1mm width cement composites covered with acoustically transparent absorptive microfibers on the front side pasted on site with sprayable glue and colour as per the choice of the architect/ person in charge with seamless finish. has excellent noise absorption of 0.85 nrc as per iso: 354-1985 and astm 423-90 a, stc of 47 as per astm e90/413 for 25mm, density 400 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60o celcius(140o farenhite) for 15 days= no deterioration. conforms to en 131682001 and are rohs complaint and anti-bacterial test as per jis-z2801-2010.to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results (ceiling absorption nrc 0.9 )etc complete. 64 providing wooden micro perforated fr grades 600x600 / 600x1200 16mm made of mdf backed with acouscal fleece providing sound absorpon of abs. coeff. 0.92 @125hz as per (equivalent to iso: 354-1985 & astm 423-90).to be installed with hidden aluminium profile conforms to aluminium alloy 6063-t6.temper as per bs:1474-1987. the density per panel is 750-800 kg/m3. these panel are made from acouscal fibreboard with linear perforaons for excellent uniformity. the perpendicular holes areavailable on the panel. wooden micro perforated can be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm acousc wool tested as per fire retardant astmd 635- 1991/insulation and is 15061-2002 for excellent result wall treatment upto 8ft height etc completeof himalyan acoustics / baux / baswa or equivalent etc complete. 65 providing and fixing ‘aphony cortex’ splendortiles made of wood fibre 1mm widthcement composites 25 mm thick (non magnesite bonded) and covered with acoustically transparent woven fabric on the front side, with an option of colours as per the choice of the architect/ person in charge of size 1200x600/ 600x600 mm.providing sound absorption of 1 nrc as per iso:354-1985 and astm 423-90 a, stc of 49 as per astm e90/413 meets the stringent fire ratings astmd- 876 and bs:476, weather resistant as per is 3308 thermal conditivity result 45 w/m2/kas per is:3346-1980. conforms to en 131682001.to be installed with pvc h profile on g.i studs600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of himalyan acoustics. 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 thermal conductivity test , w/mk , as per astm c 518 test result ( sc-6490) -0.03312for excellent results.wall absorption nrc 1 etc complete. 66 providing fibrette doodle 25mm walls himalyan acoustics / baux / baswatiles made of wood fibre cement composites with an option of colours as per the choice of the architect/ person in charge of size 1200 x 600 mm highly recommend for walls / ceilings. has excellent noise absorption of 1 nrc as per iso: 354-1985 and astm 423-90 a, density 400 kg/ m3, meets stringent fire ratings astmd-876 and fire class -1 and class p-not easily ignitable as per bs-476-part 5,6,7, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60° celsius (140° fahrenheit) for 15 days= no deterioration. tested as per en 131682001 and are rohs complaint. to be installed on g.i studs 600x600mm centre to centre2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life witha backing of himalyan acoustics 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results wall absorption nrc 1 etc complete. 67 providing and fixing ‘aphony fibril’ tiles20 mm with himalyan acoustics / baux / baswa or equivalenttaper edge made of compressed wood fibre made with (non-magnesite bonded) inorganic compound with mat blackcolour of size 600x1200/600x600mm. has excellent noise absorption of 0.70 nrc as per iso: 354-1985 and astm 423-90 a, stc of 48 as per astm 90/413 density 650-750 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , tested as per astm c 367-99 to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of himalyan acoustics. 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002for excellent results.make etc complete. 68 providingfloor carpet ofhimalyan acoustics / baux / baswa or equivalent with specification : weight :875 dynamic loading ( bs 4052)nominal thickness ( mm): 4.00color fastness tested as per.is 5641wash ( is 11969)light ( is 0686)flammability test ( is 5641) etc complete. 69 providing and fixing of acoustic door ofhimalyan acoustics / topakustik / baswa or equivalent of 56 mm having an stc rating upto 59.6 @ 100 hz as per iso:140/astm90/413. the door will be filled with high acoustic materials of 2 layers of 8 mm water proof acoustic ply with dampner sheet, 2 layers of 10mm thick absorb wool 300 gsm, sound dampner 12mm 1218x1218 mm made of 10 mm compressed wood cement composites 1250kg/m3 and 2mm dampner sheet 37 stc as per iso 140 (part-iii) - 1995. final finish with teak ply 4mm thick interior and exterior side. door frame will be made of teak wood teak wood/ engineered wood. frame on all four sides or three sides frame and drop seal below will be provided along with the door. high load bearing hinges will be provided along. fr tested as per is:3614 (pt. ii) & bs: 476-(pt.20 & 22). 70 providing and fixing of teak wooden flooring of himalyan acoustics / baux / baswa or equivalent of20mm thickness with polish. teak wooden flooring with tongue and groove system with size 510x90x20mm. termite treated seasoned. to be installed on ply board 16mm.floor polish charges included etc complete. 71 supply & installation of auditorium tip-up chairs:seat to be mounted on center pedestal 75mm x 100mm mounted on ms plate 200mm x 200mm x 6mm thickness. seat & contoured back made in cold injection moulded pu foam of density of 60kg/m3 and 46kg/m3 respectively over metal structure.19 0colored cushion (fabric colour to clients choice) with removable seat cover.seat and backrest frames are made out of metal frame structure black powder coated.upholstered back to with multi angle adjustable mechanism upto 30 degrees inclination.counterweight silent/noiseless tip up seat mechanism, seat shall be able to be removed easily for cleaning and maintenance without the need of any tools. solid armrests laminate finished (wooden appearance) seat number in oval acrylic and row number in metal plate, with provision for wiring to put led illumination. strength & durability of seat to comply to en12727: 2016 for level 4 load test.fire resistance to meet bs5852 & bs 7176warranty 5 years. price inclusive of transportation with all leads and lifts etc, complete. 72 statue- balasaheb thakreproviding statue of 15 ft height in 1st quality fiber material with metal armature (jindal). with internal structure pipe 100mm dia pipe welded together with support pipe in between and arm also with the same pipe of size 1mtr-0.5 mtr the overall height would be 3.5mt from ground. item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. material made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. structural stability certificate will be given. 73 sculpture-1 man sitting providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 74 sculpture 2 man with hammer sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 75 sculpture 3 women standing- sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care 76 sculpture 4 buffalo- sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 77 sculpture-5:- man with calf and calf sculpture -providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 78 sculpture-6:- man standing sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 79 selfie point i love haldi providing & fixing of 2.8m x 2.8 m with height of 2.8m. frp kiosk. made of frp material with dark wood finish. frp dustbin included in the kiosk. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5viscosity aliphatic paint. with long standing life. item is including placing, installation with all fittings, fixture, hardwares , all as per design, drawings & as per instructions from engineer in charge etc. complete on site.
  • View Tender
  • Document
  • Bid Support
6 Construction
image image
State Government
TRN :49023042 |  13 May, 2025
Tender Value : 0
 Bareilly - Uttar Pradesh
Tender for tender for work of installation of ac, networking, water geyser, water cooler, ro, desert cooler, inverter, battery and 30 kva dg set in the newly constructed stf building in bareilly district - supply & installation of split direct expansion air- conditioner suitable for operation on a/c supply single phase 50 hz 230 volt with hermetically sealed compressor with dc inveter technology air cooled condenser with one indoor and one outdoor unit.complete in all respect. 2.0 tr bee 5 star rated eer 3.4 2 supply & installation of split direct expansion air- conditioner suitable for operation on a/c supply single phase 50 hz 230 volt with hermetically sealed compressor with dc inveter technology air cooled condenser with one indoor and one outdoor unit.complete in all respect. 1.5 tr bee 5 star rated eer 3.4 3 s/f automatic voltage stabilizer 4 kva voltage range 130 v to 300 v with copper winding for 1.5 tr ac. 4 s/f automatic voltage stabilizer 5 kva voltage range 130 v to 300 v with copper winding for 2.0 tr ac. 5 s/f of 2.5 sqmm 3 core copper wire round cable for providing the power supply from the indoor unit to the outdoor unit for split ac. 6 sitc of suction/discharge copper pipe line in split ac unit 1.5 ton capacity including brazing, nitrile, rubber insulation 6 mm thick classo etc. complete 1/4 (6.40mm) and 1/2 (12.70 mm). 7 sitc of suction/discharge copper pipe line in split ac unit 1.8/2.0 ton capacity including brazing, nitrile, rubber insulation 9 mm thick classo etc. complete 3/8 (9.50 mm) and 5/8 (15.90mm). 8 s/f of heavy duty pvc plastic braided 20 mm od flexible drain pipe for condenses water drain with clipping accessories complete. 9 s/f of m.s angle iron mtg. bracket for outdoor unit of split ac with antrirust paint. 10 supply & installation of bajaj electric water heater geyser (25 liter storage capacity) 11 supply & installation of blue star water cooler with r.o.(150 liter storage capacity) 12 supply & installation of kent r.o. + u.v. with12 liter storage capacity 13 supply & installation of bajaj desert cooler heavy duty. 14 supply & installation of luminious inverter sine wave2350 va with 2 no. battery 180 ah tubular type above make. 15 supply & installation of cat 6 (305 mtr/coil) 16 supply & installation of dual i/o port box 17 supply & installation of 24 port gb switch. 18 supply & installation of patch cord 3 mtr 19 supply & installation of cable casing/mtr 20 sitc of silent diesel generator set of 30 kva capacity 3 phase,3 cylinder, 1500 rpm, liquid cooled with amf control panel. acoustic enclosure shall be made of pre-treared and power coated crca sheet. the sheet shall be pre-treated and powder coated with weather proof paint. the acoustic enclosure shall be vermin proof. complete in all respect. 21 supplyandlayingof aluminiumconductorpvcinsulated armoured served sheathed cables 1100 volts grade on wall surface as directed by enginer in charge complete in all respect including excavation and refilling. the armouring of the cable shall be properly connected with the earth conductor with clamps etc.25 sq. mm 3-1/2 core 22 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 31/4 x 25 sq. mm (28mm) 23 earthing with g.l. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 24 supplying and laying 25 mm x 5 mm g.l. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with g.l. nut, bolt, spring, washer etc. as required. (jointing shall be done by overlapping and with 2 sets of g.l. nut bolt & spring washer spaced at 50mm)
  • View Tender
  • Document
  • Bid Support
7 Educational And Research Institute
image image
Boards / Undertakings / PSU
TRN :48996540 |  13 May, 2025
Tender Value : 1.47 Crore
 Matunga - Maharashtra
Tender for repair, renovation, and reconfiguration of lab 1 at the computer engineering and it engineering department, first floor, vjti, matunga, mumbai.= 1 dismantling of existing partitions, wall paneling, etc., all complete as per site requirements, and stacking the usable materials within building premises as directed by the architect/consultant/ engineer-in- charge, etc. complete. (lead upto 100 meters) 2 removal of cement tiles, existing flooring, wall tiles,marble, polished shahabad flooring, dado with or without bed concrete, including stacking the materials as directed, with all leads, lifts, etc., complete. (lead upto 100 meters) 3 dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. complete. ( lead upto 100 meters) 4 scraping the old paint from the plastered internal surface using a dust-free vacuum paint scraper, followed by coating the entire surface with a mixture of whiting or glue and linseed oil, including the provision of scaffolding, as directed. (the scraping of old paint should be done until the neeru finish of the plaster is achieved.) lead and lift upto 100 meters etc. complete. 5 removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. 6 removing the existing cement plaster of any thickness without causing dust nuisance, stacking the debris up to a distance of 100 meters, cleaning the site, etc. complete. 7 providing and applying an anti-corrosive chemical to exposed reinforcement of r.c.c. members such as beams, columns, and slabs. this includes one coat of alkaline rust converter (feovert, rusticide, or equivalent) after cleaning the surface with a wire brush, followed by two coats of anti-corrosive, epoxy-based, two-component, zinc-rich primer (materemaco p 130 of basf, phenolic ipnet rb, polyalk flxoprime, or equivalent) for rebar protection on exposed reinforcement. additionally, apply a concrete-penetrating corrosive inhibitor (epco kp-100, polalk ep 113, masterseal 1414 of basf, fosroc, or equivalent) over the adjoining concrete surface. etc. complete. 8 providing and applying a bond coat of approved epoxy resin (masterbrace 1414 of basf, epi bond of krishna conchem, or equivalent) before polymer plaster or concrete to ensure a perfect bond between old concrete and new concrete/polymer plaster surfaces. the bond coat should be applied within half an hour after preparation, conforming to astm c881 type 2. this process includes the use of nylon brushes, scaffolding, labor, etc. complete. 9 providing and applying ready-mix polymer-modified cement mortar with an average thickness of 15mm, using polymer in one or more layers, in a proportion of 1:5:15 (polymer, cement, and quartz sand) as per the manufacturers specifications. the surface should be cured after 72 hours of application using wet gunny bags, etc. complete. 10 providing and applying ready-mix polymer-modified cement mortar with an average thickness of 30mm-50mm, using polymer in one or more layers, in a proportion of 1:5:15 (polymer, cement, and quartz sand) as per the manufacturers specifications. the surface should be cured after 72 hours of application using wet gunny bags, etc. complete. 11 providing and applying a 30mm thick self-curing ceramic polymer microconcrete of an approved make, having a compressive strength above m30, non-shrink, and impermeable, as a filling mortar for load-carrying r.c.c. members in two layers on cleaned concrete surfaces, including honeycomb areas (using manual or mechanical means). the mortar shall be prepared by mixing nicosil c80 and fresh 53-grade cement with the required water-cement ratio to achieve the desired consistency. the application and finishing shall be done by manual trowelling. curing shall be carried out after the initial setting time, in accordance with the manufacturers specifications. the work shall be executed in line with the specifications and as directed by the engineer-in-charge. the work must be carried out by a certified applicator, and the work shall be guaranteed for 5 years. the guarantee shall be provided on a rs. 500/- stamp paper. (the bond coat, as per item no. 08 in the boq, is to be applied before the coating.) 12 providing and applying 12mm thick internal/external ready-mix plaster conforming to is: 4031 (part-4) 1988 and is: 383-1970, in a single coat using cement mortar in a proportion of 1:4, with a special type of polymer additive (approximately 0.4%), on all types of surfaces in all positions, including scaffolding and curing. the plaster shall be followed by a smooth finishing coat of gypsum plaster of 6mm thickness, ensuring an even, smooth surface suitable for painting. complete with necessary curing, scaffolding, and all other related works. 13 providing and applying a priming coat over new/old steel and other metal surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter. the surface shall be scoured with wire brushes, fine steel wool, scrapers, and sandpaper, with scaffolding as required, etc. complete. 14 providing and applying priming coat over new wood and wood-based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter, sanding, knotting, scaffolding, etc., complete. (brands such as asian paints, dulux paints, nerolac, berger, royal, or equivalent make.) 15 providing and applying two coats of synthetic enamel paint of approved color to new/old structural steel work and woodwork in buildings, including scaffolding if necessary, cleaning, and preparing the surface (excluding primer coat). etc. complete.(brands such as asian paints, dulux paints, nerolac, berger, royal, or equivalent make.) 16 removing and refixingof doors and windows with frames and stacking the materials as directed, including all leads, lifts, labour, fitting etc., complete. (lead up to 100 meters) 17 providing and laying in pattern 600 mm x 600 mm vitrified tile flooring of 8 to 10 mm thickness and confirming to is 15622-2006 ( group bla) of approved make,quality, shade and pattern for flooring . the tile flooring shall be laid in pattern with 2 mm spacers & tiles fixed in cement mortar of 1:4. the rate shall be including floor chipping to attaining required levels, epoxy grouting of joints using approved matching colour tile grout of epoxy grout, necessary protection of the laid floor, acid wash cleaning for any stains before handover. etc. complete as per the drawing, specification and to complete satisfaction of the engineer. rate to include the wastages as per the pattern indicated in the layouts. brands like kajaria, johnson or similar etc. groove shall be filled with grout of approved shade ( brands like laticrete etc.) as dicectedby the engineer-in-charge. etc. complete. basic rate for tile material- rs. 1440/- per sq.m. 18 providing and fixing skirting, including labor, materials, and all related work, etc., complete. rate for skirting of height up to 150 mm. 19 vinyl flooring for hod cabin:providing and fixing approved color homogeneous flooring, 4mm thick with interlocking system, single-layered flexible spc vinyl flooring (spica by tusker vinyl floorings) in roll form, over the provided i.p.s. or kota stone flooring. the flooring will be fixed using approved adhesive, and all joints will be soldered with pvc rods as per the manufacturer’s specifications. the work will be completed as directed, ensuring proper leveling and cleaning. the roll width will be a minimum of 2.0 meters, and the weight of the pvc flooring will be 90 kg per 30 sqm. as directed and approved by engineer in charge. etc complete. basic rate for vinayl flooring material- rs. 900/- per sq.m. 20 providing and laying vitrified mirror/glossy/matte finish tiles of size 590 mm to 605 mm x 590 mm to 605 mm with a thickness of 8 to 10 mm, conforming to is 15622:2006 (group b1a) from an approved make, shade, and pattern, for dado and skirting in the required positions. the tiles shall be fixed in 1:4 cement mortar, including neat cement float, filling of joints, curing, cleaning, and all related work, etc., complete. basic rate for tile material- rs. 790/- per sq.m. 21 providing second-class burnt brick masonry with conventional/i.s. type bricks in cement mortar 1:6 in the superstructure, including striking joints, raking out joints, watering, scaffolding, and all related work, etc., complete. 22 lowering the debris obtained from breaking and removing cement plaster/burnt brick masonry from the first floor by any means, without causing dust nuisance or damage to the structure. the debris shall be stacked as directed by the engineer-in-charge, including cleaning the site, etc., complete. (lead up to 100 meters.) 23 removing and disposing of debris from the site to a dumping ground outside the vjti premises (in accordance with municipal rules), etc. complete. as directed by the engineer-in-charge. (minimum 6 cu.m debris per trip) 24 providing anti-termite treatment to the wooden frames of doors and windows of the existing building as per i.s. 6313 (part-iii), by drilling 6 mm dia. holes at the four corners on one side and the four corners on the other side, at a downward angle of approximately 45 degrees at the junction of the woodwork and masonry. injecting 150 ml of chlorodane 5% w.c. into each hole and sealing with putty, etc., complete, with a 2-year guarantee on bond paper. 25 providing and applying waterproof melamine polish of the required finish to the woodwork by spray machine, including knotting and preparing an even surface by scraping, applying french polish, scaffolding if required, etc., complete.note: the work is to be executed only with prior approval from the superintending engineer. (brands such as asian paints, mrf melamine or equivalent.) etc. complete. 26 providing and fixing ss t/u/l strip profiles for walls, ceilings, tiles, flooring, main doors, interior decoration, bathrooms, and living rooms, including transportation, wastage, labor, etc., complete.shape: t/u/l profilematerial: ss 304 grade stainless steeldimensions: 8 mm to 12 mmlength: 2440 mm (8 feet), 3048 mm (10 feet)type: t-sectionfinish: polishedposition: interiorcolor options: gold, rose gold, black, silver, champagne, antique hairline, antique copperthickness: 2 mm to 8 mmnote: the shape, pattern, color, and design will be directed by the architect/consultant/or engineer in charge. basic rate for material- rs. 850/- per number. 27 providing and fixing ss t/u/l strip profiles for walls, ceilings, tiles, flooring, main doors, interior decoration, bathrooms, and living rooms, including transportation, wastage, labor, etc., complete.shape: t/u/l profilematerial: ss 304 grade stainless steeldimensions: 16 mm to 32 mmlength: 2440 mm (8 feet), 3048 mm (10 feet)type: t-sectionfinish: polishedposition: interiorcolor options: gold, rose gold, black, silver, champagne, antique hairline, antique copperthickness: 2 mm to 8 mmnote: the shape, pattern, color, and design will be directed by the architect/consultant/or engineer in charge. basic rate for material- rs. 850/- per number. 28 providing and fixing sign boards foor doors:specification for waterproof signage boards (12 x 4 inch)size: 12 inches (l) x 4 inches (h) (with size tolerance is plus or minus 1%)material: high-quality, durable acrylic or pvc boardfinish: glossy or matte finish for clear readabilitywaterproof: weather-resistant, suitable for both indoor and outdoor usedesign: custom text, graphics, or logo engraving/printingmounting: wall-mountable with adhesive backing or screw mountscolors: available in multiple colors with contrast for visibility (e.g., white, black, silver)application: ideal for office cabins, rooms, labs, and other signage needsthis durable, waterproof signboard ensures clear and professional signage in various environments. including wastage, etc. complete. basic rate for material- rs. 460/- per number. 29 providing and fixing of 3d wall panels that can be painted as well.size of each panel: 2 x 2 feet.colour: any color, design, or pattern.features: lightweight, fire-resistant, easily diy, 100% recycled.made from natural bamboo plant fiber, etc., complete. basic rate for material- rs. 450/- per number. 30 providing and fixing wooden decorative fluted wall panels/louvered wall panels:material: high-quality wood (mdf, plywood, or hardwood) with a decorative veneer finish.dimensions: 8 feet x 4-5 inchesthickness: 8 mm - 12 mmdesign: fluted design with vertical or horizontal grooves for a decorative effect.color: multicolor/any colour. (customizable to match interior themes).shape: rectangular panels for seamless installation, etc., complete. basic rate for material- rs. 850/- per number. 31 providing and fixing machine cut mirror polished 16 mm to 20 mm thick telephone black / amba white / cat bary brown / rbi red / ocean brown granite stone partition with rounding the edges etc. complete. one side polishbasic rate for granite material- rs. 2530/- per sq.m. 32 providing and fixing oval-type under-counter wash hand basin of 16-inch x 22-inch size and of special color shade, having telephonic black/colored granite of 180mm thick stone black kadappa framework, including chromium-plated coupling bottle trap. the wash basin should be of cera company or equivalent, model no. 3448, as per the detailed drawing or as directed by the engineer-in-charge, etc., complete. (counter size 1.20m x 0.60m). (brands such as jaquar,kohler or equivalent make.) basic rate for wash basin - rs. 6000/- per number. 33 providing and constructing a granite kitchen platform with the installation of a stainless steel sink (600mm x 450mm) as per the detailed drawing, including vertical polished kadappa stone supports (25 to 30mm thick) on both sides, with a kadappa top (35 to 40mm thick) and a polished granite top (16 to 20mm thick). the platform will feature granite strips at the front and both sides, with two vertical granite supports (15 cm height). the top granite will be 75 cm x 40 cm, including cutting and opening for the sink of the required size in both kadappa and granite. the platform size is 5.00 m x 0.60 m, with a height of 0.75 m, etc. complete with all required finishing. basic rate for ss sink- rs. 6000/- per number. 34 supply and installation of 600x600mm modular metal perforated grid ceiling system (cg-01)the ceiling system shall be supplied and installed as per the specifications provided in the tender document, and in accordance with the directions and approval of the engineer-in-charge. the scope includes complete installation with all necessary materials, components, and finishing to ensure proper execution etc. complete. 35 providing and installation of aluminum frame works for partition with ply on both sides and laminate finish: providing and fixing partition aluminum frame work consist of 25mm x 50mm x 1.2mm thick extruded aluminium box section framework at spacing not exceeding 600mm centre to centre both ways (horizontal and vertical). the framework shall be secured at floor structural ceiling and sill/ lintel level with 25 x 50mm x 1.2mm thick horizontal aluminium section. framework to be secured to floor / walls / columns / ceiling / beams using 75mm metal screws and dowels.acoustic infill: providing & fixing acoustic insulation of approved make to g.i./ aluminum/ ms/ wooden frame partition of 50mm thick rockwool of density 48 kg/m with blanket wrapped in rp tissue suitably affixed to partition framework using where necessary gi binding wire duct tape as indicated in the drawing.outer skin:- providing and fixing 18mm plywood of brands like greenply, century or equivalent. finished with 1 mm thick laminate of approved shade applied on plywood of brands like formice, royal touche or equivalent brand.note: rate is as per aluminum framework with both side ply and laminate. etc. complete. 36 providing and fixing of laminate cladding with ply backing:providing and fixing 12mm bwr plywood (brand: greenply, century, or equivalent), directly fixed to the column. a 1mm thickness laminate of an approved shade, applied on the plywood surface. laminate brands: formica, royal touche, or equivalent. etc complete. 37 providing and installation of glass partition (toughened glass): providing 12mm toughened fixed glass partition including all patch fittings, ensuring smooth and even flush joints between glasses, fixing the same in positions to true line and level, finishing the wall joints with clear silicon sealants, cleaning the surface and ensuring that there are no scratch marks on the glass etc. complete as per drawing and specifications, glass brands should be dorma, ozone or equivalent. 38 providing and installation of glass partition (dgu glass): double-glazed unit glass with air spacer of 6 to 16mm, 95% transparency, etc. complete as per drawing and specifications, dorma or ozone or equivalent. 39 providing and installation of 12mm thick clear toughened glass door with film as required. (d2 - 0.91 x 2.10 m) specification:hardware: door to be complete with hardware to each leaf as follows: hinges: 8 nos. ss ball bearing butt hinges. door closer: concealed door closer with hold open. lock set: dead lock as approved.door handles:900mm ht. 36mm dia d type offset handle on both sides in approved powder coating. door stop: floor mounted door stopper as approved seals: drop down floor seal as approved. security system: na note: all the metal profile sections and hardware finish should match the frame. brands like dorma or ozone or equivalent. etc. complete as per drawing and specifications. 40 providing and installation of d1 - double door two-way sliding motorized door, suitable for door openings up to 1.20 meters with a maximum door weight of 100kg (both leaves). the door offers environmental protection with a working temperature range of -20°c to +50°c and is rainproof. it has a standard opening time of 3-8 seconds, with a remote control operating distance of 100 to 200 feet (depending on line of sight). the opening size is 2.4m x 2.10m, and the glass door size is 1.2m x 2.10m. brands like dorma, ozone, or equivalent, to be installed as per drawing and specifications. etc. complete. 41 providing and installation of d3 - 1.09m x 2.10m (single shutter) 12mm toughened glass door with fixed side panels, including all patch fittings, locking mechanisms, and ensuring smooth, even flush joints between the glass panels. the door is to be fixed in position to true line and level, with wall joints finished using clear silicone sealant. the surface should be cleaned and inspected to ensure there are no scratch marks on the glass. installation to be completed as per drawing and specifications, with brands like dorma, ozone, or equivalent. etc. complete. 42 pop punning: providing and applying of plaster of paris punning(1st quality isi approved pop) over plastered with minimum thickness of 8mm-12mm to existingwall surfaces, ceilings & concrete members etc., to be finished in line and plumb with smooth surface ready to receive paint base. rate to be inclusive of edge protection (gi), fibre mesh for service conduits,hacking wall surfaces for better bonding, cleaning, scrubbing the surface, providing grooves if necessary etc., complete as per architects/consultant/engineer-in-charges approval. brands like gyproc, armstrong, shera or equivalent etc. complete. 43 plastic emulsion paint (leed compliant, low voc): providing and applying plastic emulsion paint finish to walls, partitions, and ceiling surfaces of approved make, color, texture, and shade in two coats, with surface and finish acceptable to the engineer in charge to be achieved within these two coats. any additional coats, if required, shall be at the contractors cost. the work includes preparing existing surfaces by scraping away loose particles, dust, etc., washing and scrubbing, filling cracks with crack filler and binder, cleaning and making the surface dust-free, applying water-based rj london putty as directed, rubbing with sandpaper to smooth the surface, and applying one coat of primer as recommended by the approved paint manufacturer. the work also includes providing necessary scaffolding, cleaning, and protecting the site until handover, as well as masking and protecting all service devices such as switchboards, detectors, etc. the work is to be completed at all heights and leads, as per specifications or as directed by the architect/engineer in charge/consultant. brands like asian paints, berger, or equivalent are acceptable. etc. complete. 44 providing and applying premium decorative wallpaper high-end or custom designs (special finishes, custom patterns)specifications: material: non-woven fabric or vinylroll size: 21 inches wide x 33 feet long (covers 55 sq ft)pattern: various styles (floral, geometric, etc.)finish: matte, gloss, or texturedinstallation: peel & stick or pastefeatures:scratch & water-resistanteasy to clean (wipeable)fade-resistanteco-friendly, voc-freeideal for: living rooms, offices, and accent wallsmaintenance: clean with a damp cloth, no harsh chemicalscustom options: available in various colors and patterns, custom designs upon request. basic rate for wallpaper rs. 600/- per sqm. 45 standing platform (300-450 mm from ffl):construction of a standing platform at a height of 300 mm to 450 mm from the finished floor level (ffl), as per approved dimensions. the platform will be made of 18 mm thick wood (century, greenlam, or equivalent) and finished with wood polish (asian paint wood tec, mrf, or equivalent).materials:frame: mild steel or aluminum, powder-coated for corrosion resistance.surface: high-quality plywood, mdf, or approved materials with a non-slip finish.support: sturdy metal beams or supports for stability.features:height: 300 mm to 450 mm from ffl, as per design.finish: non-slip surface with smooth edges and protective coating.safety: non-slip tread and optional guardrails. etc. complete. 46 stage flooring: supply and installation of interlocking rubber tile flooring at the stage area as per the specifications and drawings provided. the flooring will consist of a 6.0 mm synthetic sport surface, including a =1.50 mm pur protect® treated vinyl surface layer, calendared and grained, supported by a pvc density single closed-cell foam, and reinforced with a fiberglass grid structure. it will feature sanosol treatment for fungistatic and bacteriostatic properties. the flooring will meet the following standards: weight: 3.7 kg/m², impact resistance (en 1517) =8 n/m, abrasion resistance (en iso 5470-1) =350 mg, shock absorption (en14808) =25% (labosport result = 28%), indentation resistance (en 1516) =0.5 mm, ball bounce (en 12235) =90%, vertical deformation (en 14809) =3.5 mm, sliding coefficient (en 13036-4) 80–110, fire (en 13501-1) cfl-s1, anti-viral activity (human coronavirus 229e) – iso 21702 (99.37% after 2 hours), energy return (nf p 90 203) =0.31 m/s, tvoc after 28 days <100 micrograms/m³ (iso 16000-6), floor score®, ce marking, en14904 compliant for multi-sports use, reach compliant, and singapore green label certified. the supply and installation will include making good any damaged surfaces using standard fillers such as birla white cement, cement-based grout, epoxy grout, or mortar, and repainting to match the color.all work will be completed in accordance with the specifications, design, drawings, and the direction of the engineer-in-charge. 47 providing and fixing of overhead storage as per the specifications and drawings provided in the tender document. etc. complete. 48 providing and fixing of surface storageas per the specifications and drawings provided in the tender document. etc. complete. 49 providing and fixing on-site a lab table as per the specifications and drawings provided in the tender document. etc. complete. 50 providing and fixing of office desk/table in faculty lounge as per the specifications and drawings provided in the tender document. etc. complete. 51 providing and fixing of office desk/table in office for hod as per the specifications and drawings provided in the tender document. etc. complete. 52 supply and installation ofhod cabin chair as per the specifications and drawings provided in the tender document. etc. complete. 53 supply and installation of faculty lounge chairs as per the specifications and drawings provided in the tender document. etc. complete. 54 supply and installation of study chairs for labs as per the specifications and drawings provided in the tender document. etc. complete. 55 supply and installation of foldable desklet tables for the seminar hall as per the specifications and drawings provided in the tender document. etc. complete. 56 removingthe exisitng light fixures, fans, wires, cables, swith boards and distribution boards etc. complete. 57 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm (2+1e) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg-pw/sw. (brands for conduits precision/finolex/pressfit. and for cable barnds should be polycab/finolex/havells. etc. complete 58 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 2.5 sq.mm (2+1e) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg-pw/sw. (brands for conduits precision/finolex/pressfit. and for cable barnds should be polycab/finolex/havells. etc. complete 59 supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a / 25a switch combined with indicator lamp and fuse with gang box on wooden board.make /brand (roma/ legrand,/ greatwhite) etc. complete 60 supplying and erecting isi mark modular type 3 pin 6a / 16a multi socket with safety shutter, duly erected on providedplate and box with wiring connectionsetc.complete. brand : roma/gretwhite/legrand) etc. complete 61 supplying and erecting pvc surface modular double mounting plate 3 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) 62 supplying and erecting pvc surface modular double mounting plate 4 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 63 supplying and erecting pvc surface modular double mounting plate 6 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 64 supplying and erecting pvc surface modular double mounting plate 8 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 65 supplying and erecting pvc surface modular double mounting plate 12 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 66 supplying and erecting regular/ standard model ceiling fan of 1400mm with sweep complete erected in position as per specification no. fg-fn/cf brand /orient/polycab/crompton etc. complete 67 supplying and erecting flush-type ceiling fan regulators and electronic step regulators for ceiling fans (600mm, 900mm, 1200mm, and 1400mm sweep), complete with installation on the provided switchboard. make/brand: roma, legrand, or greatwhite. 68 providing and fixing 36 watt 2x2 light fitingsupplying and erecting square shaped crca /die-cast aluminium powder coated housing led panel light (slim edge-lit) 600x600mm suitable for 36 w-40w includingmotion sensor led light with provision for plane front frame with translucent cover fixed to the housing etc.complete .brand philips/havels/wipro etc. complete 69 supplying and erecting 16 to 32 a dpmcb suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 70 supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (24 poles) or tp mcb of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb1 (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 71 providing & erecting 3 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/tripalarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 72 supplying, erecting & commissioning 4 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw-rccb/rccb. (make/ brand: legrand/ schneider/ l&t/ indo asian) 73 supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg-tw etc. complete. cables brands should be polycab/finolex/havells. etc. complete 74 supplying and installing cat-6 cable suitable for networking as per specification no. wg-coc/nc. cables brands should be polycab/finolex/havells. etc. complete. 75 supplying & erecting mains with 2 x 2.5 sq.mm. and earth wire 1.5 sq.mm frlsh pvc copper wire in hms pvc conduit min. 20mm dia. as per specification no: wg-ma/pc.etc complete. brand :polycab/finolex/havels) etc. complete 76 supplying, erecting & terminating xlpe armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.cb-lt/cu(brand: polycab/ finolex/ havells)note - the quantity of wires for looping the required number of air conditioning units has to be calculated by the contractor with respect to the provided architectural working drawing. etc. complete 77 providing & erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) gi sheet of 150 mm width & 20 mm height complete with necessary hardware. cable tray brands should be profab or equivalent. etc. complete 78 supplying and erecting pvc box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification no: wg-ma/box. etc. complete (make/ brand: legrand/ schneider/ l&t) 79 supply & fixing of aluminum box section to be laid on the floor with all excavation, re-cementing & refinishing civil works to make good in line with the existing floor level respective junctionbox to be fabricated in 16 swg gi sheet with cut out as required for terminating the box sections. shall include pvc conduits from jb to work station powerpoints i)150 x 150x 50 mmgijunction box with cover & cut outs etc. complete. (make/ brand: legrand/ schneider/ l&t) 80 supply of a.c split unit (2 ton) :supply of ac split unit as per the specifications, and drawings provided in tender document. make (carrier/ voltas/ bluestar/ samsung) etc. complete 81 supply of 2 ton casatte ac:2 ton inverter casette ac. cooling capacity 3200-8000 watt. offers uniform 360 degree round airflow, with 4 star energy rating. etc. complete. make (carrier/ voltas/ bluestar/ samsung) etc. complete 82 installation of 2 ton ac split unit etc. complete 83 installation of 2 ton ac cassette unit etc. complete 84 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigerant having 22swg thickness and inner dia/size 22mm complete. etc. complete. material selection should be high quality and from reputed brand as directed by engineer in charge. 85 supply & installation electrical communication cable between indoor to outdoor units.cables brands should be polycab/finolex/havells. etc. complete. 86 providing and fixing in position ms frame stand for a.c. units, floor or wall mounted, with vibration isolation pads and frame to be made out of required ms sections strong enough to hold the weight of the ac unit,and should be lockable, including fixing in position using necessary scaffolding, ladder etc, and painting with two or more coats ofapproved enamel paint on a coat of red oxide etc. complete 87 insulated condensate water drain piping constructed out of pvc / hdpe hard pipeswith 6mm thick nitride insulation, fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors fasteners and concealed in brickwork or flooring. etc. complete(make: finolex/ astral/ prince) 88 supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided pc / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/ac system. etc. complete. material selection should be high quality and from reputed brand as directed by engineer in charge. 89 supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 20a, 2 pin plug & earth socket and 20a, 3 pin plug top with 20a/30a single pole mcb having rated short - circuit breaking capacity (icn) 10ka complete erected on angle iron/ gi frame. etc. complete 90 carrying out core cutting of size 3 to 5 dia x 15 length in the c.c./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. etc. complete 91 supply and installation of roller blindsas per the specifications and drawings provided in the tender document. etc. complete. basic cost for blind cloth fabric material rs.900/- per sq.m. 92 carrying out test for ceramic tiles / vitrified tileswater absorption, modulus of rupture (set of 6 tiles) etc. complete. 93 carrying out test for plywood: determination of resistance to dry heat,determination of moisture content,determination of density,thickness of plywood. etc. complete. 94 carrying out test for test for glue adhesion for plywood etc. complete. 95 carrying out test for hollow / solid /aac blocksdensity test. (set of 3 blocks), compressive strength. (set of 3 blocks), water absorption test (set of 3 blocks) etc. complete. 96 providing and fixing 15 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 97 providing and fixing 20 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 98 providing and fixing 25 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 99 providing and fixing on walls/ceiling/floor 32mm dia cpvc pipe with necessary fittings, remaking good the demolished portion, etc., complete. including removing existing pipeline if necessary and conveying and stacking the same in pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 100 providing and fixing 75 mm dia stabilizer pipe/p.v.c. soil vent/waste pipe with necessary fixtures and fittings, such as bends, tees, single junctions, slotted vent, clamps, etc., complete. 101 providing and fixing 100 mm dia stabilizer pipe/p.v.c. soil vent/waste pipe with necessary fixtures and fittings, such as bends, tees, single junctions, slotted vent, clamps, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 102 providing and fixing 10 cm pvc nahani trap with grating, etc., complete. (brands such as astral, finolex, prince or equivalent make.) basic rate for nahani trap is rs. 380/- 103 providing and fixing c.p. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. basic rate for pillar cock is rs. 1250/- per number 104 providing and fixing of exhaust fan 150mm crompton/havels/usha or equivalent etc. complete. basic rate for exhasut fan is rs.1000/- per number 105 providing and fixing stainless steel round napkin hanger for bathroom/towel holder for wash basin/napkin holder/bathroom (chrome) b. heavymaterial stainless steel product dimensions 17l x 5w x 19h centimetersfinish type chromeinstallation type wall-mounted shape round including fitting etc. completed.basic rate for material is rs. 320/- 106 providing and fixing premium front glass shelf - bathroom shelf/kitchen shelves wall mounted with frosted and toughen (tradition 6 x 18) chrome including fitting etc. complete. basic rate for material is rs. 650/- 107 providing and installation of 6 mm thick mirror with 6 mm thick ply backing, as per design. the mirror will be supported by stainless steel finished buttons, etc., complete. (the glass brand should be saint-gobain, borosil, or an equivalent make) basic rate for mirror is rs. 1250/- per sq.m. 108 supply and installation of nsd make smoke detectormodel:66a, certification: ce & ertl etc. complete. 109 supply and installation of nsd make heat detectormodel:66h, certification: ce & ertl etc. complete. 110 supply and installation of response indicator make: nsdmodel: p.s (mini) etc. complete. 111 supply and installation of manual call point (m.s) make nsd 112 supply and installation of 08 zone fire alarm panel make nsd(excel) etc. complete. 113 supply and installation of flasher hooter make nsdmodel no: ms17flash etc. complete. 114 supply and installation of supply & laying 1.0 sq. mm x 2 core copper armored isi cable for alarmsystem. with accessories per meter. brand/make :polycab/finolex/havellls) etc. complete. 115 supply and installation of high quality co2 fire extinguisher (6 kg)type:carbon dioxide (co2) fire extinguisher (for electrical fires and flammable liquids)capacity: 6 kgfire rating: class b (flammable liquids) class c (electrical fires)material: cylinder: steel or aluminum alloyfinish: red powder-coated for durabilityoperating pressure: 55 bardischarge time: approx. 8-10 secondsdischarge range: 3-5 feettemperature range:operating: -10°c to +60°c storage: -30°c to +60°cmounting: includes wall bracket certification: is 15683 (india) / ul/ce certified etc. complete.note: the rates for all fire safety alarm items include the complete supply, installation, commissioning, transportation, freight, and all associated costs. 116 providing architectural/ interior design services : scope of work as below:drawings preparation: 3d views, floor plans, furniture layout, electrical layout, ceiling layout, and partition layout.color scheme & material selection: guidance on colors and material choices for finishes, flooring, and furniture.quality control: ensure standards for structural, civil, electrical, fire safety, furniture work and hvac work.interior planning: optimize lab functionality and aesthetics, including furniture, partition design, and system planning (electrical, hvac, fire safety).modifications: suggest changes to designs based on site conditions and client feedback.coordination & monitoring: ensure project progress and timely completion by working closely with contractors. deputation of interior designer degree/diploma/certificate course having knowledge of autocad and 3d home or equivalent for the full period of the work. designes. monitor on-site execution, ensuring design adherence. taking joint measurements.preparing statements for extra items and excess quantities.compliance & safety: ensure adherence to safety codes and regulations. etc. complete.
  • View Tender
  • Document
  • Bid Support
8 Security Services
image image
Central Government/Public Sector
TRN :34413160 |  13 May, 2025
Tender Value : 0
 Visakhapatnam - Andhra Pradesh
Tender for gem bids for procurement and installation for upliftment of office space for static test facility 3d mural work with department silhouette , plaque for commissioning crew , acrylic poster 24 18 with stud fitting , acrylic motivational wall posters of 18 12 with stud fitting , pleated acoustic wall paneling with medium density fiberboard slants made of melamine laminated finish with perforated groove slants , textured embossing with dual layer putty and single coat primer and dual layer emulsion , texture vinyl layering anti skid double layered with wooden finish , flag post with flags , customized rope light fixtures for ceiling lightning in officer in charge cabin and conference hall , ceiling embossing with gypsum sheet and 18mm channel and finished with dual coat putty , ceiling emulsion dual layering with multi coat finish , customized toughened glass entrance with dept crest etching on both sides , indoor plants for lobby corridor waiting lounger conference room and other areas , name tallies for all cabins rooms , 54inch height toughened glass side wall for open porch area shatter proof and double strengthened for safety , toughened glass white board with waterproof makers 36 48 , toughened glass white board with waterproof makers18 24 , overhead profile ceiling beside visitor area and guard room 14 16 8 8 based on self drilling screw finished with dual coat of anti rust coating , zebra blinds screen roller with nai logo underneath on all windows , 2d mural painting of naval history with dept crest and navy crest on either side 160ft 30ft as per approved design
  • View Tender
  • Document
  • Bid Support
9 Security Services
image image
Central Government/Public Sector
TRN :48280497 |  17 May, 2025
Tender Value : 4.14 Crore
 Leh - Ladakh
Tender for tender for provision of central mi room at nimu(job no 01/nimu stn/amwp/2023-24); 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 43 2 lump sum price worked out by the contractor for (site clearance, excavation & earth work)as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 44 3 lump sum price worked out by the contractor for (internal electrification)as listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 50 4 lump sum price worked out by the contractor for (internal water supply)as listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 52 5 lump sum price worked out by the contractor for (road, path & hardstanding)as listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 54 6 lump sum price worked out by the contractor for (sewage disposal)as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 55 7 lump sum price worked out by the contractor for (area drainage)as listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 56 8 lump sum price worked out by the contractor for (shed for dg set)as listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 58 9 lump sum price worked out by the contractor for (hot water supply)as listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 59 10 lump sum price worked out by the contractor for (external electrification)as listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 65 11 lump sum price worked out by the contractor for (external water suplay)as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 66 12 sch a part - xii (misc b/r & e/m items) (refer boq)note: this schedule is not pre-priced by mes and the rate indicated as rs 0.00 under col 5 signifies this fact only 13 internal electrifications&f double door three phase prewired distribution board vertical db vtpn 8 way with acrylic door made out of crca sheets 1.6 mm thick,phosphatised powder coated with copper bus bar 200 amps, 415 v,ip 43/ik09, earth stud, din rail, polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingmccb4 pole 63 amp rating repturing capacity 16 ka.(note:- single phase mcbs are to be measured and paid for seperately) 14 s&f led building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240v, ip 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long med grade gi pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith ms clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm pvc insulated 3 core wire complete all as directed and specified by engr-in-charge.note - cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 s&f new wall mounted fan of approved make and type complete all as specified and as directed. 16 s&f tv co-axial socket 1 module, complete all as specified and as directed. 17 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole mcb 20 amps 18 internal water supplys&f single piece vitreous china wash down water closet pan pedestal pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type b-0, as in repairs complete all as spd & directed complete all as specified and directed by engr-in charge.. 19 s&f cp grating including jointing to waste pipe fixed in cement concrete type b-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by engr-in charge. 20 s&f hand shower (health faucet ) with 8mm dia and 1 meter long cp flexible tube and wall hookcomplete all as specified make: cera, jaquar , marc & hindware as per sample and directed by engr -in charge 21 s&f soap dish (s/s), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by engr-in charge. 22 road, path & hard standingm&l for wet mix macadam (wmm) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of morth (ministry of road transport & highways) specification of road and bridge works 2013. manufactured in wmm plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 kn static weight and conslidating required gradient and camber. the finished surface tolerance to be as per table 900-1 of morth specification for road and bridge works 2013 complete all as specified and directed by engr-in-charge. 23 m&l for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to bs 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 m&l for rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m-30 design mix in walls , base slab , baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 m&l for soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonary in cm, rcc cover slab in m25/ sfrc cover, interconnecting pipes of rcc/dwc complete filled with brick bats of size 3m dia and 3 m depth. 26 s&f pvc junction boxes ip 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 nos mcb sp 2.5 amp & 4 way industrial connector including clamp made out of ms flat 30x5mm connection from junction box to street light fitting with three single core pvc insulated, pvc sheathed wire 2.5 sqmm copper & pvc conduit 20 mm dia complete all as specified and directed by engr-in-charge. 27 excavation in trenches by cutting of road crossing/pcc hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by engr-in-charge. 28 s&fht/lt ms cable route indicator 4 dia fixed with two nos of nut, bolt and washers and provision of pcc 1 : 4 : 8 type d-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by engr-in-charge. 29 supply, installation, testing and commissinoning lt panel board suitable for working on 3 phase ,4 wire ,415 volts, ac ,50hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick crca sheetduly powder coated and shall be cpri approved and as approved by ge. the panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, copper bus bar duly covered with heat shrink sleeves colour coaded duly fixed ondmc/smc insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing mccbs shall have extended bus bar links and mounted on 50x50x5mm sizems angle iron frame duly painted including pcc 1:2:4 type b1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of age (i) nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) mccb 400 amps, fp, 36 ka, 415 volts, 50hz - 01 no (i/c)(b) mccb 200 amps, fp, 25 ka, 415 volts, 50hz - 02 no ( chs)(c) mccb 125 amps, fp, 18 ka, 415 volts, 50hz - 04 nos (apfc, tpn db -02, spare )(d) mcb spn 40 amps, 10 ka, 220 volts, 50hz - 03 nos (garage,street light, spare-1)(e) on load chengeover 630 amps 4 pole -01 no (f)digital voltmeter, with vss - 01set(g) digital ammeter, with cts & ass - 01 set(h) led phase indication lamps ryb - 01 set(j)single phase rotary automatic light controller nature switch with voltage range 120-440v,ac,20 amps,ip-65,50hz-01 nos(k) copper bus bar tpn 600 amps rating - 01 set 31 labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and gi tubing in soft/loose soil complete all as specified. 32 m&lfor cutting existing gi pipes and insertion of new tee branches of suitable size to take branch connection of 50mm dia pp-r.note : suitable size of tee branch is deemed to be included in the quoted rate. 33 construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingpcc in foundation of the mixture (1:4:8) d-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) ms steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed ms work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in pcc with two coats of black bituminuos paint andall other relevant work complete . 34 m&l for providing tracer/anti freezing cable required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (central heating system)electric hot water generator : supply, installation, testing and commissioning ofpackage type electric hot water generator constructed out of ms sheet having top open-able cover for easy access and removal of heaters. the hwg shall be suitable for indoor mounting. the generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22g aluminium cladding sheet. the generator shall have electrical capacity of 50 kw. the heater shall be electrical resistance type, copper tube with chromium plating. the generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. the generator shall be suitable for 3 phase, 415+ 10% volts, 50 hz. ac supply. the generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 notes:- (i) allneccassary accessories required for the proper fucntioning of hot water genearator are included in price.(ii) the prices should include lifting, shifting and positioning of units at site.(iii) hot water genearator installation to done as per manufacturer recommendation with all installation requirements i.e foundation, vibration isolator,insulationetc as recommended by manufacturer for the ambient temperature of site. odu installation is included in odu price which includes the civil struture, mechanical structureetc as recommended bymanufacturer.(iv) the contractor/oem will shall submit the hot water generator capacity/burner capacity conforming to relevant is code(v) oem should submit the installation and maintenance schedule/ manual for the boiler. 37 glycol circulation centrifugal pumps: supply, installation, testing & commissioning of pn16 ratedaxial split coupled vertical inline water pump set with ci casing, bronze impeller, ss shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with suitable hp, tefc squirrel cage induction motor with ie3 type class f insulation, motor shall be rating of ip 55, operating on 415 ±10% volts, 3 phase, 50hz ac supply. the external flush line must be used for the purpose of heat dissipation from the mechanical seal.pumps with performance characteristics as given below:the internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 degree celcius to 120 degree celcius. vendor shall be provide antivibration arrangement for pumps . 38 the scope also shall include following below mentioned:(i) electrical by pass starter for pump setas recommended by oem. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) pressure gauges 150 mm dia -03 nos (iv) mounting frame with antivibration pads (in case pumps are inline, anti vibration system shall be as per manufacturers recommendation) (v) rcc/cement concrete foundation for the pump unit. (in case pumps are inline, foundation shall be as per manufacturers recommendation).pump capacity are as under:capacityand pump headnot less than flow 25 usgpm , head 20 mtr (refernce model no. : armstrong : series 4300 - 40-150 - 2p - 1.5 kw) each including the triple duty valve and end suction guide. 39 expansion tank and pressurisation unit:supply, installation, testing and commissioning of insulated pressurised closed water expansion tank suitable for total volume ofglycol - water solution, circuit along with necessary accessories such as along with necessary accessories such as 2 nos pumps (1working +1standby) with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. the tank shall be pre-charged. expansion tank shall be with replaceable heavy duty butyl rubber bladder. the tankconnections should be as per oem recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.the tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. the tank must be constructed in accordance with is-standard 2825-1969 (withlates revision)and rated at pn 16 . the complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.the tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelip55 control panel, pressure transmitter, interconnecting piping & wiring. (tank capacity 500 ltrs). hot glycol - water closed vessel pressurized expansion tank as described above shall be duly insulated with 50 mm thick puf/nitrile rubber insulating material or equivalent u valueinsulating material and cladded with aluminium sheet (20g). electrical by pass starter for pump setas recommended by oem. 40 expansion tank of 500 lts capacity 41 pressurization unit: for pump set -03 nos with control panel and accessories. 42 make up tank: supply, installation, testing and commissioning of factory made make up water tank, rectangular/circular shape, of 4 mm thick ms sheet (is 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of ms and vent with flame arrestor. tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above ffl. service platform shall be provided as per recommendations of oem. the tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. extra high level and extra low level alarm shall be provided. tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.make up water tank as describedabove should beduly insulated with 50 mm thick puf/nitrile rubber insulating material and cladded with aluminium sheet (20g). 43 supply, installation, testing and commissioning ofsteel plate radiator( wall mounted) confirming en- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°c, complete with top grill side cover as standard along with inlet ,outlet valve, air purge valve andwith threaded plug, flow regulator as per oem.the below desired capacity should be calculated at altitude of 3600 mts above sea level. capacity calculation sheet to be provided to engineer in charge. the below mentioned capacity is at inlet temp: 75 degree celcius , outlet temp: 65 degree celcius. referemcwe model series. 44 1.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 45 2.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 46 3.5 kw,type: 33- dkek, length is 1600 mm and height is 600 mm of radiator. 47 5 kw,type: 33- dkek, length is 1600 mm and height is 900 mm of radiator. 48 5 kw,type: 33- dkek, length is 2000 mm and height is 600 mm of radiator 49 m & l for pre-insulated ms pipe,class c havingminimum thicknes of puf insulation as mentioned below and of density 36 kg/cum and 26 gauge al cladding complete suitable for above ground as per sizes shown.the pipes should be insulated with closed cell puf of density 36±2 kg/cum of below mentioned thickness. the pipe should be workable in the temp. range of-50 degree celciusto120 degreec celcius. note:-the pipes size 150mm & below shall be m.s. ‘c’ class as per is : 1239 50 80 mm with 36 mm puf thicknes and 26 gauge al cladding. 51 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 52 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 53 40 mm with 36 mm puf thicknes and 26 gauge al cladding. 54 20 mm with 36 mm puf thicknes and 26 gauge al cladding. 55 buried under ground/exposed to ambient:80 mm with 50 mm puf thicknes and hdpe cladding, 26 gauge al cladding. 56 cabel tray :-supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ground/wall with m.s. suspenders as per is code including bolts & nuts, painting suspenders etc. as required of size 150 mm width x 50 mm depth x 1.6 mm thickness 57 supplying, fixing, testing and commissioning of following diameter valves (pn-16 rating) (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), strainers (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), gauges etc for condenser water circulation as per specifications. insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified. butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets.butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets. 58 80 mm dia butterfly valve 59 65 mm dia butterfly valve 60 50 mm dia butterfly valve 61 supplying, fixing, testing and commissioning of y-strainer (insulated valves) of ductile ci body flanged ends with stainless steel strainer forhot water circulation including insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified of size 50 mm dia y strainer. 62 supplying, fixing, testing and commissioning of non - return valve (insulated valves) with duel plate of ci body ss plates vulcanized nbr seal flanged end & pn 16 pressure rating forhot water circulation includinginsulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as sepcified of size 50 mm dia nrv. 63 supplying, fixing, testing and commissioning of automatic air purge valves forhot water circulation headeras specified of size automtic air purge valve 20 mm dia. 64 supplying, fixing, testing and commissioning of air separator compleate allas specified of size 50 mm dia. 65 supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and ss tubing, socket.range (0-50) / (0-100) as required by engineer in charge. 66 supplying, fixing, testing and commissioning of mercury in glass industrial thermometer in ss-304 casing with 0.5 c least count, range 0-50 c. brass oil filled thermowell of 1/2 size as required by engineer in charge. 67 electrical distribution panel supply, installation, commissioning and testing of factory made, chs plant, indoor type made out of crca sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with ms angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 phase4 wire, 415 volts, 50 hz, ac supply system, floor mounted and grounting the legs of panel in pcc foundation 1:4:8 complete as all directed suitable for and including the following :- 68 incomers(i) bus bar tpn al extensible type main bus bars of minimum of 600 a capacity (as per capacity of corresponding incoming / bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c smc bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50ka .(ii)mccb 400 amps, 415 volt, 36 ka, 4 pole,microprocessor release- 01 no for incoming (extended rotary operating handle, phase spreader links and phase barriers ) make: legrand/schenider/simensoutgoings(i) 3nos- 125a ,25 ka tpnmccb/acbwith microprocessor release (3# hot water generator)(ii) mcb 10 amp,tpn,10ka, c curve - 06, 3 nos for pumps , 2 nos for pumps ,01 nos for glycol transfer pump(iii) led phase indication lamps (01 set) with 2amp back up mcb,breaker on/off indicating light with 2a mcb, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 set (iv) digital ammeter with in built ass,metering c.t.scast resin type, 15va, and accuracy class-1of 800/5a for measuring current in each phase - 01 set.(v) all accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per manufacturers recommendations all as directed by engnr-in-charge.note : contractor will submit the drawing for approval of panel to ge before execution. 69 lt cables : supply & laying/ fixing of following size xlpe insulated and pvc sheathed copper conductor armoured cable/unarmoured as required of 1.1 kv grade complete as require (isi marked) (in ground/in pipe/in duct/on surface/on cable tray) 70 3.5 core x 70 sq.mm. (electric hot water generator) 71 4.0 core x 10 sq.mm. (pump) and (pressurization unit) 72 2 core x 10 sq.mm. (pump) 73 2 core x 6 sq.mm (pressurization unit) 74 earthing complete with copperearth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long gi pipe connected to main controlboard and gi pipe light grade 20mm bore for watering and including funnel, wire mesh, rcc pit cover 50mm thick and pcc chamber pit with pcc 1:2:4 type c2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate no 3 of ssr part-i 2009 complete all as specified & directed by engr-in-charge 75 s&f rubber matting conforming to is-15652-2006 complete as required. of size2m x 1m x 25 mm 76 glycol - water solutionsupplying of ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.note;- (i) the glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. the glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 degree celcius (ii) first charge of glycol is included in the quoted rate. first charge include charge in chs pipe linestorage tank. (glycol 45 % ,water 55 %) 77 for chs 78 supply of gycol for running of plant for 12 months 79 glycol circulating pump: supply, erection, testing and commissioning oftransfer pumps for the capacity of 5 lpm 5 meter head for glycol fluidtransfer with base frame foundation, bolts coupling coupling guard,tefc, (oem design hp for the required flowand head ) andother accessories for proper function of the pump. 80 oxygen gas manhold : supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, nrv and essab make 10x14 regulator complete all as specified and directed by engr in charge . 81 supply , installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by engr in charge . 82 supply , installation , testing and commission automatic control panel with analog display 02 for oxygen complete all as specified and directed by engr in charge. 83 s&f of copper tubing of size 15 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 84 s&f of copper tubing of size 12 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 85 s&f bs type gas outle with probe for oxygen for medical compleate all as specified and directed by engr in charge 86 s&f 1/2 brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by engr in charge. 87 s&f bpc flow meter (0-15 lpm) including humidfire bottle complete all as specified and directed by engr in charge . 88 s&f 3/8 brass ball valveincluding all fittings for complete all as specified and directed by engr in charge. 89 stand by dg set : supply,install, test and commissioning of silent diesel engine generating set 415 volts, 3 phase, 4 wireengine as per is08528 conforming to cpcb norms iv, and alternator as per is08528 of capacity 400 kva at ntp with control panel having meters, sound proof canopy etc with foundation (as per oem design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- ac generator should be suitable for ambient conditions at nimu leh area. 90 (a) alternator : standard design alternator rated at 400 kva (320kw)net output at power factor 0.8, ac, 3 phase 4 wire, 415 v, 50 cycles/second, 1500 rpm self excited, self regulated, screen protected, drip proof ip 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (b)diesel engine : vertical diesel engine of suitable capacity, water cooled, closed circuit as per bs-649 or is-1002 direct injection type turbo charged, electric starting system having rated speed 1500 rpm. the dg set shall be capable for running with 10% over loading for 01 hour in every 12 hours as perbs-5514/bs-649. engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following specifications.(a) fly wheel with housing (i) common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) cooling system (i) radiator with fan & belts & guard, rubber hoses and thermostat. (ii) cooling water pump centrifugal type . 91 (c) governer : electronic governer (d) electric starting system : electric self starter , 24 volts dc(12 volt, 150 ah battery 2 nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2x12 volt 150 ah capacity. (e) generator monitoring panel : comprising of following :- (i) microprocessor based genset controller for metering, monitoring, governing and protection. (ii) engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) accessories:avm pads built or separately mounted to manufacturer base frames. (g) coupling arrangements: fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) exhaust system : should have equipped with emission control device as per latest govt norms. silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) fuel tank: daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (c)acoustic enclosure : all as per cpcb norms iv and oem of dg sets design.(d)amf panel : supply, install, testing and commissioning of amf panel outdoor type, cubical body,dust and vermin proofmade up of crca sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to ip 45 with front and rear opening with louvers andmounted on floor with pcc pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) microprocessor based panel -01 no(ii) power contactor heavy duty suitable for generator and mains (iii) over load relay for genset (iv) suitable rating isolating switch mccb for both dg & main supply.(v) multi functioning meter to indicate voltage, current, frequency, p f, kw & kwh etc (vi) emergency stop push button.(vii)set of indicaters : - (a)low lube oil pressure (b) dg set over load(viii) push button to start, stop (ix) mode selector switch i.e auto/manual/test/ off.(x) set of instrument fuse (xi)set of aluminium bus bar of 600 amps capacity 3 ph, 4 wire system (xii) automatic battery charging unit with dc voltmeter, ammeter and selector switch for trickle/ boost charging.(xiii) by pass arrangement of main supply when amf circuit fail due to any fault with provision of suitable rating change overs and switches. 93 the following items are deemed to be included in the rate quoted for all dg sets:- (i) dhpp for testing purpose shall be supplied by the contractor without any extra cost to department. (ii)the contractor shall arrange for artificial load (water load/electrical load) for testing for final testing of dg set at site and the cost is deemed to be including in above offer. (iii) testing of sound level should carried out at the site in presence of engineer-in-charge(iv) one set of latest spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) all civil works including foundation for dgset as per manufacturers drawing/ specification, foundation for amf panel shall deemed to be included in the quoted rate.(vi) the rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
  • View Tender
  • Document
  • Bid Support
10 Construction
image image
State Government
TRN :49051926 |  16 May, 2025
Tender Value : 30.36 Lacs
 Panaji - Goa
Tender for construction of hall and supplying gym items for pinto youth club of baradi in velim constituency under mla-lad scheme.--demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. 2 demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. 3 laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. 4 extra for laterite masonry in all sizes in superstructure from floor i level upto floor v level. 5 12mm cement plaster 1:4 (1 cement : 4 fine sand) 6 providing and fixing 1st quality ceramic glazed wall tiles (johnson somany kajaria ) conforming to is:15622 (thickness to be specified by the manufacture of approved make in all colours shades except burgundy bottle green black of any size as approved by engineer-in-charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.;wall ceramic glazed tiles : 300 x 600 7 providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of johnson somany kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to is: 15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc. complete;dark shades 8 proving and fixing white vitreous china wall hung type (european type) water closet with seat and lid with c.i. brass hinges and rubber fittings with flush valve nelson/ similar fully chromium plated with stop cock wall flanges flush pipe or elbow and vaccum breaker coupling etc. including chair bracket/rag bolts cutting & making good the walls and floors where required and concealed seat support - w.c. pan with white plastic seat and lid 9 providing and fixing brass stop cock (heavy) of approved quality :;15 mm nominal bore 10 providing and fixing brass full way valve (heavy) duty with wheel of approved quality :;20 mm nominal bore 11 providing and fixing p.v.c. connection pipe with brass unions 15 mm nominal bore:;45 cm (18”) length . 12 providing and fixing rigid pvc s.w.r. (soil waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:; 110 mm dia 13 providing and fixing rigid pvc bend (approved make) for s.w.r. pipes including lubricating etc complete bend with door :; 100 mm dia 14 providing and fixing nahani trap of rigid pvc (approved make ) for s.w.r. pipes including lubricating etc complete without door :;110 mm dia 15 providing and fixing nickel chrome plated copper alloy fancy bib cock short body jaquar make or equivalent.confirming to is 8931; 1993;15mm nominal bore 16 providing and fixing chlorinated ployvinyl chloride (cpvc) pipes confirming to is:15778 having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. this includes jointing of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of the engineer-in-charge. concealed work (medium duty sdr 13.5 pipe) including cutting chases and making good the walls etc.;20 mm dia nominal outer dia pipes. 17 providing and fixing hand shower (health faucet) with 8mm dia abs/brass body with double lock 1.00 m long flexible tube (brass plated stainles steel flexible hose) and wall hook of approved quality confirming to is standards. 18 frp (fiber reinforced polymer) frames with wood finish manufacture supply and installation (with anchor fastener) of epee or equivalent goan make frp (fiber reinforced polymer) frame of cross section as per options below with right angle joint and frp (fiber reinforced polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). the core of frame would be filled with seasoned wood as infill material. the slot of frame for door resting will be of suitable width so as to take specified thickness door.the frame will be water proof as well as mild acid/ alkali resistant manufactured in an iso 9001- 2015 certified company.;specified cross section;4” x 2” 19 wood finish wood core frp (fiber reinforced polymer) door shutter. manufacture supply and installation (including accessories as mentioned below) of epee or equivalent goan make frp (fiber reinforced polymer) door shutter of specified thickness as per options below by using tray system with seasoned hard wood moisture less than 17% wooden styles for top rail and lock rails. frp (fiber reinforced polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) and printed matt having wooden textures used along with uv resistant resin to give the clear texture on the door. the core of shutter will be filled with mr 2nd grade block board. the shutter to be water proof as well as mild acid / alkali resistant manufactured using rv tifac (r v engineering college bangalore & technology information forecasting & assessment council) technology in line with is 13034 1990 test standard in an iso 9001 – 2015certified factory. accessories: i) s. s. hinges 4” - 3 nos ii) s. s. latch - 1 no iii) tower bolt 5” - 2 nos iv) handle 5” - 2 nos;shutter thickness;32mm 20 providing and applying white cement based putty of average thickness 1.00 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. 21 applying one coat of cement primer of approved brand and manufacture on wall surface. 22 wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. 23 painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. 24 applying priming coat with ready mixed primer of approved brand and manufacture on steel work. 25 providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts nuts and wooden plugs and embeded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size.;40 x 3 mm flat iron hold fast 15 cm long 26 providing and fixing m.s. grill of required pattern in wooden frames of windows etc. with m.s. flats square or round bars with round headed bolts and nuts or by by screws.; plain grill 27 centering & shuttering including strutting propping & removal of forms for :;columns piers pillars aburments posts and struts (square rectangle polygon in plan) 28 centering & shuttering including strutting propping & removal of forms for :;sides and soffits of beams beam haunchings cantilever girders bressumers and lintels plinth beams not exceeding 1m in depth 29 centering & shuttering including strutting propping & removal of forms for :;suspended floors roofs landings shelves & their supports 30 providing and fixing 18 mm thick gang saw cut mirror polished premoulded and prepolished machine cut for kitchen platforms vanity counters window sills facias and similar locations of required size approved shade colour and texture laid over 20 mm thick base cement mortar 1: 4 (1 cement : 4 coarse sand) joints treated with white cement mixed with matching pigment epoxy touch ups including rubbing curing moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite of any colour and shade area of slab over0.50 sqm;jet black 31 providing and laying in position machine batched concrete (bmc) machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering shuttering finishing and reinforcement including admixtures in recommended proportions as per is 9103 to accelerate retard setting of concrete improve workability without impairing the strength and durability as per the direction of the engineer-in-charge. m25 grade of reinforced cement conrete by using 410kg of cement per cu.m. of concrete. all works upto floor v level. 32 providing tmt steel reinforcement bars of (sail tata. vizag jsw steel ltd.) ) (confirming to is 1786 of 1986) for rcc work (conforming to i.s. 1786 of 1986) including bending binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. 33 providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the engineer-in-charge: windows with three sliding shutters using 18 mm series shutters section.;plain glass 34 extra for powder coating with pure polyester powder of shade of required colour on the aluminium section 35 providing and fixing vitreous china wash basin with rs or c.i. brackets painted white 15 mm c.p. brass pillar taps c.p. brass chain with rubber plug 32 mm c.p. brass waste of pattern 32 mm diameter m.i. or c.p. brass trap and union complete including cutting and making good the walls where required.; flat back wash basin size 550 x 400mm with a single 15 mm c.p. brass pillar taps. 36 providing and laying in position cement concrete 1: 2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering shuttering and finishing :;all works upto plinth level 37 providing and fixing astm upvc pipe conforming to astm 2467 with iso 14001 including all upvc plain & brass threaded fittings including jointing of pipes & fittings with one step upvc solvent cement trenching refilling & testing of joints complete as per direction of engineer. external work.;sch-80(blue)/(w hite);40mm outer dia. 38 providing and fixing g.i. chain with g.i. pull. 39 providing woodwork in frames of doors windows clerestory windows trusses & other frames wrought framed and fixed in positon.;second class indian teak wood 40 providing and fixing 38 mm thick panelled glazed or panelled and glazed shutters for doors windows and clerestory window including black enamelled iron butt hinges with necessary screws:;second class indian teak wood 41 applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete. 42 painting two or more coats (excluding priming coat) with superior quality ready mixed paint for wood work of approved brand & manufacture in all shades on new work to give an even shade. 43 providing & fixing chromium plated brass tower bolts (barrel type) with necessary screws complete.;250 x 10 mm 44 providing and fixing chromium plated brass sliding door bolt with bolts nuts and screws etc. complete.;300 x 16 mm 45 provided and fixing 150 mm chromium plated brass floor door stopper with rubber cushion screws etc. to suit shutters thickness complete. 46 provided and fixing chromium plated brass 100mm. mortice latch and a pair of levers and handles with necessary screws etc. complete (indian make of approved quality). 47 providing and and laying vitrified floor tiles in different sizes of johnson somany kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigment etc. complete;600 x 600 mm light shades 48 false ceiling:-;providing & fixing false ceiling yashashri make or equivalent made out of 2” x 1” m.s sq tube frame support structure & 20mm x 155mm x 1.2mm multi- cavity upvc section 30mm x 40mm x 2mm upvc multi-cavity section with hidden screwing system.the average weight of false ceiling is 8.50 kg per sq mtr. these upvc sections are tested by using bs 2782 & din 53459 test methods. 49 providing & fixing of aluminium lay-in perforated tile ceiling on 24 /14 mm ‘t’ framework of module 600mm x 600mm. tiles of size 575mm x 575mm / 584mm x584mm made out of 0.6mm thick aluminium. perforation of the tiles shall be 2.5mm dia 5.5mm c/c. the tile shall be manufactured on advanced equipment which includes several levelling. the tile end shall be raised upward by 38mm and bend outward to lay the tile in framework. the tile shall be polyester based powder coated in white colour. grid system for fixing ceiling tiles shall comprise of tees. the 24 /14 mm main tee runners shall be suspended at an interval of 1200mm centre to centre. the 24 /14 mm cross tee runner shall be suspended at 600mm centre to centre and further supported with 24 /14 mm cross tee at 600mm centre to centre with interlocking arrangements to form grid of 600mm x 600mm. the main tee shall be supported by means of 4mm g.i. rod from slab/roof. the suspension shall be provided at 1200 to 1500mm centre to centre.tee framework would be made of gi and powder coated. acoustic felt: non- woven felt made of glass-r einforced fibre glued over the perforation for sound absorption. 50 providing water proofing treatment over the new r.c.c. roofs terrace toilet by spreading cement slurry over the r.c.c. slab and laying of 10cms. average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of hindustan water proofing co. or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand) finished smooth with wooden trowel with false marking of 30 cms square. the vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. the injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb cracks etc. in the r.c.c. slabs). note: cement consumption 25 kg/sq.m. 51 providing & fixing colour coated alluminium (puf) sandwich panel roofing systems of approved make adhering to aluminium 3105 grade for top & bottom sheet of thickness0.40 & 0.35 respectively including puf insulation betewwn the top & bottom sheet of denslity 40 (+/-2) kg/m3 inclusive of s.s. 304 grade self tapping fastneres complete as directed by enigneer incharge (frame work for roof roof accesorries to be paid seperately) for tile design puf roof panel gutter width should be atleast 25% more than the crest width. minimum height at heighest point of crest should be minimum 65mm. minimum thickness at anygiven point should not be below 30mm.;puf insulated tile roof 30mm thick of trapezoidal design 52 steel work in built up tubular (round square or rectangular hollow tubes etc.) (square hollow section (shs) is4923 /rectangular hollow section (rhs) is4923/circular hollow section (chs) is1161 closed structural steel of (sail tata. vizag jsw apollo steel ltd.) make (min yeild stress 310 mpa)) trusses etc. including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc. complete. 53 providing and fixing in position s.s. hand rail in main stair case and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials etc. complete. 54 melamine polishing on wood work (one or more coat);glossy 55 providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the engineer-in-charge: adjustable louvered window s.;figured glass 56 extra for powder coating with pure polyester powder of shade of required colour on the aluminium section 57 6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand) 58 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. 59 painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as dulex/ asian paints/ sherwin willians) including applying one coat of cement primer and one coat of surface treatment etc. complete. 60 painting one or more coats of acryllic exterior paint of approved brand and manuf acture(such as dulex/ asian paints/ sherwin willians) on old work including cleaning the surface with water etc. complete. 61 providing & fixing alluminium ridge of approved make adhering to alluminium 3105 grade of 0.71mm thickness & 60 cm wide inclusive of ss304 grade self tapping fastners to match the alluminium roofing system & as directed by engineer in charge complete 62 providing & fixing alluminium 30mm trapezhoidal end cap for puf roofing of approved make of alluminium aa 3105 grade matching with 30mm puf panel profile including the required fastners etc. complete for alluminium puf roofing system & as directed by engineer in charge. 63 pvc wall paneling : providing and fixing pvc sheet wall paneling of thickness 5mm (±0.25) consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm (±0.25) thick prelam pvc sheet.the panel & strips shall be of 600 kg/cbm density manufactured by an iso-9000 certified company. the strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two pvc strips. the pvc strips shall be fixed to the wall using 65mm long m.s. screws through the groove in the strip by using pvc fasteners. the distance between two screws shall not be more than 200mm. a groove of 2mm may be left at the joint of two panels for aesthetic looks. the exact size of the panel and correspondingly of the grid may vary depending on the size of the wall.optionally a strips of 5mm (±0.25) thick pvc sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined using solvent cement. 64 providing and installing rubber dumbells of hexagonal shape and approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 65 providing and installing barbell rod 5ft of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 66 providing and installing skipping rope of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 67 providing and installing yoga mat 6mm thick of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 68 providing and installing punching bag of 900mm diameter of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 69 providing and installing bench press multidegree of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 70 providing and installing rowing machine of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 71 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. a)2.50 kg 72 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. b) 5.00 kg 73 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. c) 7.50 kg 74 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. d)10.00 kg 75 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e)12.50 kg 76 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e) 15.00kg 77 providing and installing dumbell rack of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 78 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. a) 2.00 kg 79 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. b) 4.00 kg 80 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. c) 6.00 kg 81 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. d) 8.00 kg 82 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e) 10.00kg 83 providing and installing gym ball 65cms of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 84 providing and installing gym ball 75cms of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 85 providing and installing push up bar with chrome finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 86 providing and installing ab wheel roller finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 87 providing and installing foam roller finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 88 providing and installing air bike of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge.
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : acoustic work
  • Civil Repair Tenders ,
  • Light House Repair Tenders ,
  • Cement Concrete Repair Tenders ,
  • Balustrade Repair Tenders ,
  • Cattle Through Tenders ,
  • Hall Repair Tenders ,
  • Staircase Work Tenders ,
  • Bus Bay Tenders ,
  • Water Booth Tenders ,
  • Railway Station Repair Tenders

Get acoustic work Tender Alert...

152755

Related Searched Keywords : acoustic work

  • Lake Development Tenders From Maharashtra
  • Earth Dam Tenders From Delhi
  • Floor Tiling Work Tenders From West-Bengal
  • Tilling Work Tenders From -Tamil-Nadu
  • Sewerage Tenders From Andhra-Pradesh
  • Brickwork Tenders From Gujarat
  • Sculpture Work Tenders From Karnataka
  • Railway Under Bridge Tenders From Uttar-Pradesh
  • Floor Tiling Tenders From Rajasthan
  • Irrigation Works Tenders From Madhya-Pradesh

Read More


Tender Document

434275

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Dismantling Tenders
  • Railway Under Bridge Tenders
  • Sculpture Work Tenders
  • Tiles Flooring Tenders
  • Sewage Pipeline Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App