Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Bakelite Tube
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of bakelite-tube Tenders

List of latest bakelite-tube Tenders in Indian Tenders. Click on any bakelite-tube Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for bakelite-tube Tenders.

Advance Search
  • All-Tenders (5)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49055122 |  29 May, 2025
Tender Value : 40.00 Lacs
 Palam - Delhi
Tender for comprehensive maintenance and certain misc b/r works in tech area at af stn palam under ge (af) palam, delhi cantt - 10; 1.00 taking down cement plaster on brick, stone or concrete surfaces of walls etc incl racking out joints hacking for key scrubbing down with water etc and removing the debris from site to out site mod land complete all as specified and directed by engr-in-charge . 2.00 m&l for 10mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on internal walls, finished the surface even and smooth without using extra cement as on wall as whole or in patch etc complete all as specified and as directed. make- birla (hil) or its equilent. 3.00 m&l for 15mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on external walls, finished the surface even and fair without using extra cement by using dr. fixit (wpc) @ 3% of wt of cement content complete all as specified and as directed. note:- water proofing compound shall be measured and paid seprately. 4.00 m&l for 5mm thick cement plater of ready mix mortar of approved make as on ceiling & plastering to be finished even & smooth without using extra cement complete all as specified and as directed. make- birla (hil) or its equilent. 5.00 supply only integral water proofing compound complete all as specified and as directed. 6.00 m&l for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkalic resistent primer complete all as specified and as directed 7.00 m&l for applying two coats of 100% premium acrylic emulsion paint having voc less than 50 gm/ltr and uv resistance as per is 15489-2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.9 litre /10 sqm over new surfaces complete all as specified and as directed. 8.00 m&l for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkalic resistent primer complete all as specified and as directed. 9.00 m&l for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed. note:- payment for providing grooves shall be measured and paid separately. 10.00 m&l for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications complete all as specified and as directed. 11.00 demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) and removing the debris from site to out site mod land complete all as specified and as directed. 12.00 m & l for 75mm thick cement concrete (1:3:6) type c2 (using 40mm graded stone aggregate) as in plinth protection, finished even and smooth without using extra cement, including making joints 12 mm wide to the full depth of pcc at every 3 metres and at every change of direction and filling the same with & including bitumen 85/25 and sand in the proportion of (1:3 ) by weight complete all as specified and as directed. 13.00 m&l for 75mm thick pcc (1:3:6) type c2 (using 40mm graded stone aggregate) as in path and paving, finished even and smooth without using extra cement complete all as specified and as directed. 14.00 m&l for 25 mm thick pcc (1:2:4) type b1 (using 20mm graded stone aggregate) as in floor, finished even and smooth with using extra cement complete all as specified and as directed. 15.00 m&l for plain cement concrete (1:3:6) type c1 (using 20 mm graded stone aggregate) as in surface channel/drain complete all as specified and as directed. 16.00 extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed. 17.00 supply and fixing in repairs, sfrc drain cover any size, 75mm thick laid over existing drain complete all as specified and as directed by engr-in-charge. notes: - (i) make of sfrc manhole/drain cover and frame : (a) m/s ps concrete.(b) m/s kk manhole.(c) or equivalent as approved by ge. (ii) contractor will provide manufacturer test certificate of sfrc cover . 18.00 dismantling wall and ceiling boards ( fibre, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness, including fillets complete all as specified and as directed. 19.00 m & l for provding false ceiling of 12mm thick fine fissure board sharped finished mineral fiber accountic false ceiling tiles with back of the duly sanded and finshed with a coat of protective paint and front duly finished false system of size (600x600) mm having noise reduction co-efficient of 0.55 light reflection of 80% thermal conductivity k=0.057 w/wwc and humidity resistance of 95% fixed to true look pvc die kl -24 suspension system (hot dipped aglvanised steel section) of exposed t section consisting of perimeter wall angle of size (24x24) mm of thickness 0.45 of mm c/c universal main runner of t shape with double rotary siticing of size (38x25) mm of lenght 1200mm made from 0.33gs steel of lenght 3.60 mtr to be spced at 600x 600mm size) c/c cro runner t shape wtih double rotary siticing of size (30x24)mm of length 1200mm made 0.25 thick gs sheet spaced @ 600mm c/c (600mm 600mm) size complete all as specified and directed by engineer -in- charge. 20.00 taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. 21.00 taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 sqm but n. exc 4.0sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. 22.00 taking down shutters of any description of size n. exc 1 sqm each complete all as specified and as directed. 23.00 taking down shutters of any description of size exc 1 sqm and n exc 2 sqm each complete all as specified and as directed. 24.00 taking down shutters of any description exc 1 sqm and n exc 2 sqm each and re-fixing in the same opening after necessary repairing viz shifting of hinges/tower bolt / handle position etc complete all as specified and as directed. note:- cost of screws/nails and minor items shall be deemed to be included in the unit quoted rates. 25.00 s&f anodised aluminium powder coated frame for door, windows, ventilators, partition wall with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed 26.00 s&f anodised aluminium powder coated door shutter, aluminium section wt 0.55 kg/m including neccesary joining cleats, glazing clips, rubber neoprene packing, aluminium handle 2 nos in each door, hinges, anodised aluminium snap beading screw etc. complete all as specified and as directed. 27.00 s&f anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised, handle 2 nos in each window, aluminium fittings such as peg stays150mm long (1 no.), hinges type b-21100mm long (2 no.), suitable handle (1no.) complete all as specified and as directed. 28.00 s&f aluminium anodised with powder coating (minimum thickness of powder coating 50 micron) grill of design and parttern as approved by ge including aluminium beading complete all as specified and as directed. 29.00 s&f 5.50mm thick tinted, sheet glass of selected quality fixed to aluminium frame work complete all as specified and as directed. 30.00 m&l for 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & fixed with screws to timber/aluminium frame complete all as specified and as directed 31.00 s & f door closer hydraulically regulated designation no 3 universal type suitable for door shutter of 851 to 1000 mm in width of aluminum body (die cast) weight between 61 to 80 kg complete all as specified and as directed. 32.00 m&l double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty complete all as specified and as directed. 33.00 s & f mild steel mortic lock vertical type size 100mm 4 levers complete all as specified and as directed. 34.00 s&f aluminium tower bolt of extruded section, 150mm length of bolt and fixed with screws complete all as specified and as directed. 35.00 s&f aluminium door stopper double legged with rubber shoe 75mm long fixed to door shutters complete all as specified and as directed. 36.00 m & l 2nd class hard wood plain, solid, straight chowkhats, and frame wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. 37.00 s&f for 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and as directed. 38.00 s&f for factory made single extruded wpc (wood polymer composit) solid door/window and other frames/chowkhat of size 50x100 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives(maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed ss screws having minimum frame density of 750 kg/cum screw withdrawl strength of 2200 n(face) & 1100n(edge) minimum compressive strength of 58 n/sqmm modules of ealsticity 900 n/sqmm and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with ms hold fast/ lugs/ss dash fasteners of required dia and length complete as per direction of enger-in-charge. make- m/s rajshree plastiwood ltd or its equivalent as per list of make. 39.00 s&f for factory made single extruded wpc (wood polymer composit) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of k value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives(maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed ss screws having minimum frame density of 650 kg/cum screw withdrawl strength of 1800 n(face) & 900n(edge) minimum compressive strength of 50 n/sqmm modules of ealsticity 850 n/sqmm and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant. wpc to be laminated with pvc foil of minimum 14 microns thick of approved design pasted with hotmelt adhesiv on both faces of shutter and fixing with stailess steel butt hinges of required size with necessary full body threaded star headed counter sunk ss screws all as direction of enger-in-charge. make:- m/s rajshree plastiwood ltd or its equivalent as per list of makes. 40.00 dismantling of floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles and rubbish off the premises complete all as specified and as directed. 41.00 m&l for vitrified ceramic tiles 8-10 mm thick, 1st quilaty (square/rectuangular) polished, double charge shade, area of each tiles exceeding 0.36 sqm but not exc. 0.42 sqm, as in floors etc. set and jointed with neat cement slurry and pointed in white or coloured cement to match with and including over15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. 42.00 description all as per srl item no. 39.00 bove but as in skirting over 10mm thick plastering with cm (1:4) complete all as specified and as directed. 43.00 m &l for ceramic coloured/ printed non-skid tiles of size 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.06 sqm but n exc 0.16 sqm laid as in floors, set and jointed with neat cement slurry with and including over 15 mm thick screed bedding layers of cement sand mortar (1:4) and pointed with coloured cement to match with surfaces of tiles complete all as specified and as directed. 44.00 m&l for glazed ceramic coloured tiles (colour & shade as approved) of size (450x350)mm x 7mm thick as in vertical surfaces as in skirting and dado, set and jointed in neat cement slurry with amd including over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed. 45.00 s&f in repair wash hand basin, vitreous china, flat back (550x400)mm size, white including pvc waste coupling 32mm size, pvc waste pipe 32mm bore, pair of brackets of mild steel (35 x 35 x 6)mm size including one mixer cast copper alloy 15mm bore, one brass stop valve 15mm bore and one pvc connection15mm size with ptmt nuts of length 450mm long complete all as specified and as directed by engineer-in-charge. 46.00 supply & fixing in repair vitreous china ewc super constellation including flushing cistern of size (83x37x66)cm with s trap complete all as specified and as directed. 47.00 supply & fixing in repair vitreous china urinal pot white including partition, waste pipe, screw with wall fixing complete all as specified and as directed. 48.00 s&f in repairs two way wall mixer with popup waste system, hot and cold facilites and 450 mm long braidaed hoses chromium plated complete all as specified and as directed . 49.00 s&f in repair health faucet with double lock 1 meter brass plated stainless steel flexible hose and wall hook complete all as specified and as directed. 50.00 s & f in repair copper alloy cp toilet paper holder complete all as specified and as directed. 51.00 m&l for replacement of 100mm ci floor/nahani trap with grating including jointing and breaking/ dismantling any type of floor and making good cement concrete type b-1 (1:2:4) and testing after repairs and taking down existing trap etc complete all as specified and as directed. 52.00 s&f in repair, brass chromium plated tubular towel rail, 20mm dia, d type, 60cm long between flanges complete all as specified and as directed. 53.00 taking up or down 15mm steel tubing and connections in walls, ceilins, floors, etc including cleaning for refixing or removal to store complete all as specified and as directed. 54.00 m&l for gi tubing, 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed. 55.00 m&l for cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good cutting not exc 10 cm girth as in wall complete all as specified and as directed. 56.00 s&f in repair 15mm bore cast copper alloy, cp angle cock, screwed down, high pressure, with crutch or butterfly handles, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. 57.00 s&f in repair pvc connections 15mm size with ptmt nuts of length 450mm and fixed complete all as specified and as directed. 58.00 s&f in repairs pvc connections 15mm size with ptmt nuts of length 600 mm and fixed complete all as specified and as directed. 59.00 s&f in repair cast copper alloy cp soap dish complete all as specified and directed. 60.00 s&f in repair bib taps with wall flange 15mm bore, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. 61.00 s&f in repair pillar cock, foam flow cast copper alloy, chromium plated, fancy type, 15 mm dia, capastan heads, screwed down high pressure complete all as specified and as directed. make:- cat no 8304 of make prayyag or equivalent as per list of makes. 62.00 s&f in repair plastic water closet seat cover, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. 63.00 s&f in repair pvc valveless, syphonic action type, flushing cistern low level, 10 litre capacity , white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. 64.00 s&f in repair 610 mm long pvc waste pipe flexible type 25 mm dia suitable for couplings 32 mm / 40 mm dia complete all as specified and as directed. 65.00 s&f in repair (600 x450) mm fancy type or bevelled edge mirror of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 66.00 s&f in repairs 15 mm bore bib taps standard of ptmt any colour high pressure screwed for iron pipe and fixed complete all as specified and as directed. (minimum weight 90 gms). 67.00 s&f in repairs 15 mm two in one angle valve cast copper alloy, chromium plated with wall flange and fancy type with high pressure screwed down and with cp flange of same make complete all as specified and as directed . 68.00 m&l for 18-20mm thick granite (of jet black ) work (table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. note:- the cost of half round moulding shall be deemed to be included in unit rate. 69.00 dismantalling water tanks and removal from site of capacity exc 250 ltr and not exc 500 ltr complete all as specified and as directed. 70.00 m &l for 500 litres capacity rotational moulded polyethene water storage tank (cylindrical vertical with closed top), white, three layers, hoisted and fixed in position complete all as specified and as directed. 71.00 supply and fixed ball brass valve high pressure with polythene float and fly nut complete to bore of pipe 20mm complete all as specified and as directed. 72.00 demolition of brick work or stone buillder built in cement mortar of any description complete all as specified and as directed. 73.00 m&l for brick work with sub class b works, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete complete all specified and as directed. 74.00 dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. 75.00 s&f mild steel work such as angle iron post, flat iron in fencing including cutting as making doubble swan neck i.e. y shaped including welding with proper overlapping & welding ms plate with angle iron bottom as directed, drilling holes notching for wire etc embedded in concrete fixed vertically conforming to fe 290 grade e-165 complete all as specified and as directed. note:- embedded portion of angle iron post shall be treated with tar of coat of tar black paint and cost of the same shall be deemed to be included in unit rate. 76.00 m&l for preparation of newly steel surfaces of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer of any height complete all as specified and as directed. 77.00 s&f for concertina coil with punched tape of 600 mm dia (when stretched), centre core wire of minimum 2.5 mm dia of mild steel wire conforming to is 280-2006 with galvanised coating of steel concertina coil as per requirements laid down for medium coated wire in is : 4826 hot dipped galvainsed coating of round steel wires. conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 150 rm for 10 rm of work ,minimum weight 13.5 kg for 10 rm of work including dismantling of existing concertina coil complete all as specifed and directed by engr-in-charge. (note:- the actual weight of concertina coil brought by the contractor at site shall be ascertained by boo as ordered by ge). 78.00 s&f for concertina coil with punched tape of 900 mm dia (when stretched), centre core wire of minimum 2.5 mm dia of mild steel wire conforming to is 280-2006 with galvanised coating of steel concertina coil as per requirements laid down for medium coated wire in is : 4826 hot dipped galvainsed coating of round steel wires. conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 180 rm for 10 rm of work ,minimum weight 16.5 kg for 10 rm of work including dismantling of existing concertina coil complete all as specifed and directed by engr-in-charge. (note:- the actual weight of concertina coil brought by the contractor at site shall be ascertained by boo as ordered by ge). 79.00 dismantling of fencing wire, barbed wire any type and description complete all as specified and as directed. 80.00 supply and fixing galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbed of 75mm spacing and straining and fixing to any type of standard rail, straining bolt including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc as directed (each line wire to be measured) complete all as specified and as directed. 81.00 m&l for cuting holes in brick walls exc half brick but n.exc one brick, built in cement mortar for fixing holdfasts in jambs of existing opening and making good complete all as specified and as directed. 82.00 m&l pcc (1:3:6) type c1 (using 20 mm graded stone aggregates) as in hold fast block including necessary form work complete all as specified and as directed. 83.00 s&f mild steel work framed such as grill, gratings, etc with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to fe.290.gde-e-165. complete as specified and as directed. 84.00 dismantling of fencing wire mesh, any type of any description complete as specified and as directed. 85.00 fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and as directed. 86.00 supply only chain link ms galvanised fencing, 4mm dia gi wire mesh size 100mm x 100mm complete as specified and as directed. 87.00 s&f mild steel screw bolts 12 mm dia (machine made) with hexagonal heads at one end and screwed other end to be fitted with washers (02 nos.) and one hexagonal nut, length of bolt exe 5 cm and n exe 10 cm complete as specified and as directed. 88.00 s&f mild steel fabricated round bars 10mm dia as in horizontal bars for chain link fencing incl necessary hooking at ends all as complete as specified and as directed. 89.00 excavation in post hole (or similar holes) each n.exc 0.50 cum getting out returning, filling in and ramming earth around in layers n. exc 25cm watering and removed surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete as specified and as directed. 90.00 supply and fixing in repairs, pre cast cement concrete jallies, 35 mm thick, type b0 1:2:4 (using 12.5 mm graded crushed stone aggregate) including wire fabric set and jointed in cement mortar (1:4) complete as specified and as directed. 91.00 s&f in repair aluminium composit panel (acp) sheet with 1x1.5 aluminium tube over the framed/ beam of gates. acp shall meet under mentioned technical requirements:- (i) coating on front : high quality polymer resin.(ii) core : fr core (fire retardant)(iii) thickness : 4mm(0.5 mm+3.0mm+0.5mm) (iv) weight : 7.50kg/sqm(v) width: 1200mm(vi) length: 1200 to 2400mm(vii) structure: aluminium panel are protective film,clear coating pvdf,primer coating,antirust layer,aluminium skin and polyethylene.(viii) temp resistance : between -50c to +80c(note:- the quoted rate is deemded to be included necessaryy scaffolding required and joint sealing) 92.00 s & f in repair 12mm thick toughened glass fixed with double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty and stainless steel handle purpose made on both side with locking machanism and with necessary stopper etc complete all as specified and as directed. 93.00 demolition and breaking up drain pipe 75/100mm dia ( salt glazed ware, ac or pvc) of any type complete all as specified and as directed. 94.00 s&f 75 mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed. 95.00 s&f 110 mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed. 96.00 s&f in repairs pvc(swr) bends any radius, 75 mm bore complete all as specified and as directed. 97.00 s&f in repairs pvc(swr) bends any radius, 110 mm bore complete all as specified and as directed. 98.00 hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. 99.00 s&f sheet glass 4mm thick ordinary quality and glazing with oil putty or rubeer bedding in square n. exc 0.5 sqm in each pane complete all as specified and as directed. 100.00 s&f in repairs of sink with drainage board, made out of stainless steel 1mm thick, kitchen or laboratory with plugs, washes and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever bracket and connecting union to pipe over all size (915x460)mm with bowl size (410x330x160)mm complete all as specified and as directed. 101.00 s&f in repair brass chromium plated shower rose,125 mm size fixed to 15 mm bore iron pipe complete all as specified and as directed. 102.00 s&f in repair water closet vitreous china squatting pan, orissa pattern size (580x440)mm white with integral foot rests (excluding flushing cistern and flush pipe) and including with p or s trap complete including provison of lime concrete bedding fixed in repair complete all as specified and as directed. 103.00 m&l for gunniting work to rcc work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and s&f welded wire mesh fabric or wire net less than 95 x 95x 3 mm tied to existing reinforcement with nails,adhesive plaster grade for concrete and providing gunniting pressure 2.0/2.5kg/sqm with admixture 1 part of cement and 3.5 part of sand with average thickness 40 mm and making the surface even including 15mm thick plastering in cm 1:4 on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement including necessary form work to be carried out,complete all as specified.(note.- wherever reinforcement required shall be measured and paid seperately) 4. structural steel steel authority of india limited (sail) brand: sail / rashtriya ispat nigam limited (rinl) brand: rinl / tata iron & steel company (tisco, or tata steel) brand: tata / m/sjindal steels and power ltd. brand: jindal 5 factory made paneled/ glazed /gauged door shutters m/s mp wood product indore, m/s jain doors pvt ltd sonipat, goyal industiral corporation new delhi, shri krishna industries, panchkula, 6 factory made flush door shutters m/s green ply industries, m/s centuary ply, m/s dura ply. mysore chip board, archid, swastik ply wood, m/s jain doors pvt ltd 7 pvc door frame/shutters sintex, rajshri plastiwood ltd, m/s dura plast extraction pvt ltd, m/s fenesta, ecocell,accucell 8 frp door frame and shutter selected products co., sintex, rajshri plastiwood ltd, accure polytec pvt ltd ,ecocell, fiberways 9 upvc window/doors fenesta, ncl veka, madhu industries, h2o solutions, yashpoly,accucel, okotech, aseco (m/s ashish industries) 10 iron mongery mowjee, m/s kitch architectural product pvt ltd, rs industries. 11 hydraulic door closer everest, universal, godrej 12 particle board(veneered & unveneered laminated)/ block board kitply, nova pan industries, new delhi, m/s green ply industries ltd, archid ply, bhutan board, dura board mysore chip board ltd 13 plywood for general purposes dura ply, archid ply, bhutan board,archid board, century, durian, mysore chip board ltd 14 decorative laminates archid lam, sunmica, merino, lam, mysore chip board,greelam 15 terrazzo tiles ntc, nitco, eurocon, duracrete 16 glazed ceramic/non skid wall/floor tiles kajaira, johnson, agl, qutone , somany, nitco, orient bell ,vitero, sunhearrt ceramik, varmora 17 vitrified tiles (polished, unpolished & glazed, normal/ anti skid) kajaira, johnson, agl, qutone , somany, nitco, orient bell,vitero,sunhearrt ceramik, varmora 18 hdpe storage water tanks sintex, supreme,plasto,polycon 19 sanitary appliances /fittings(chinaware) hindware,parryware,cera,jaquar, kohler, prayag aproyale,somany 20 water closet seats and cover (solid bakelite) thermostat moulded toilet seat cover parryware, jaquar, prayag somani,commander,cera,neycer 21 pvc flushing cisterns hindware, commander, parryware, cera ,jaquar, johnson pedar, neycer 22 stainless steel kitchen sink with or without draining board, plate rack nirali,cera,diamond,jainco,shakti prayag, (silver shine) m/s bluestar sanitary industries 23 ball valves (horzontal plunger type) dripless faucets india, flowjet , ball valves inida. 24 shower roses chromium plated (swivel type) gem,jaquar, jal 25 bath room fancy fittings jaquar,gem,marc, jalangi 26 bib taps and stop taps (cp),pillar tap, fancy fittings jaquar, parko, gem, marc 27 bathroom cabinets jaquar, cera, commander, parryware .... more in document
  • View Tender
  • Document
  • Bid Support
3 Educational And Research Institute
image image
Boards / Undertakings / PSU
TRN :49055160 |  19 May, 2025
Tender Value : 0
 New Delhi - Delhi
Tender for tender for resistive loads (rheostat) detailed tech specs. - wire temp coefficient- looppm wire grade - isotan coating grade- fire retardant tatung temp rise - 100°c above ambient stabilty- |% knob - bakelite moulded parts - brass contact-phosphorus bron/e multistrips hvir-2000 vacrms 5a 69 ohms double tube rheostat 5a 45 ohms single lube rheostat 5a 100 ohms double tube rheostat
  • View Tender
  • Document
  • Bid Support
4 Construction
image image
State Government
TRN :49022392 |  13 May, 2025
Tender Value : 31.44 Lacs
 Gangapur - Maharashtra
Tender for providing electrical installation in, premises street light, water pump and fire extinguisher for the newly constructed zilla parishad primary health center (p .h .c)main building (g.f+f.f) [under scheme d.p.c. (general) year 2022-23, 34512595 construction expantion & m/ce & repairs of p.h.c/ phsc) at village,lasur stationtq. gangapurdist. chhatrapati sambhajinagar.= 1 supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit 2 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 3 supplying anderectingpvctrunking (pvc casing-n-capping)ofsize20 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 4 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 5 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize40 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 6 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 7 supplying and erecting green earth wire 1x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 8 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 9 supplying and erecting green earth wire 1x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 10 supplying and erecting mains with 4x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 11 supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 12 supplying and erecting mains with 4x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 13 supplying and erecting green earth wire 1x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 14 supplying and erecting mains with 4x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 15 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 16 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 17 supplying and erectingceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. 18 supplying and erectingmodular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 19 supplying and erectingmodular type switch 16aduly erected on provided plate and box with wiring connections complete. 20 supplying and erectingmodular type bell-push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. 21 supplying and erectingmodular type 3 pin 6amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. 22 supplying and erectingmodular type 3 pin 6 / 16amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 23 supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. 25 supplying and erecting pvc surface modular switch box with double mounting plate for 2module duly erected. 26 supplying and erecting pvc surface modular switch box with double mounting plate for 3module duly erected. 27 supplying and erecting pvc surface modular switch box with double mounting plate for 6module duly erected. 28 supplying and erecting pvc surface modular switch box with double mounting plate for 12module duly erected. 29 supplying and erecting 16 / 20 / 25 a starter (modular range) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 30 point wiring for light/bell/exhaust fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 31 point wiring for ceiling fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 32 wiring for plug on board withswitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no: wg-pw/cw 33 supplying and erectingled square / circular max. 11 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 34 supplying and erectingled square / circular max. 14 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 35 supplying and erectingled square / circular max. 18 w down lighter/ panel light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 36 supplying and erectingledpanel light(600mm x 600mm) max. 30 whaving crca powder coated housing,polystyrene diffuser havingsystem lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 37 supplying and erecting anodized aluminium corridor / passage / mirror light led fitting (2 feet) max. 12wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%,thd<10%,p.f. >0.95, operating range of200-270v, surge protection of 2 kv, life class of 50,000 hrs. at l70b50, including driver with end caps on provided pvc block / wooden board with 3 years warranty. 38 supplying & erecting inverter led batten 10w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 39 supplying & erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 40 supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. 41 supplying and erecting integrated led street light fitting26 to 30w ip65 & ik08 class having single piece pressure die-cast aluminium housing ,having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 42 supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg-odf/fls2. 43 supplying and erecting integratedled street light fitting 100-110w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 44 supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg-odf/ptl 45 supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg-bkt/wb 46 supplying & erecting 3w, 230v integral type led lamp suitable for b-22 / e-27 base.(night lamp) 47 supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg-fn/cf 48 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. 49 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. 50 supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg-fn/exf 51 supplying and erectingenergy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg-fn/cf 52 supplying and erecting fan hook of 10 mm. m.s. round bar grouted in rcc slab with making the site as original. 53 providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 54 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no fg-fas/msc 55 supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof abs plastic body, high grade ss inner tank & 3kw heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermalcut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250v, 50hz, a.c. supply with inlet and outlet, with 3 core pvc flexible copper wire leads duly tested and marking sr. no. and date of erection complete. 56 supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). 57 supplying & erecting 15mm brass non return valve for inlet pipe of storage water heater. 58 providing fiber reinforced pvc flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete. 59 supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 60 supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 61 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigerant having 22swg thickness and inner dia/size 12mm complete. 62 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigeranthaving 22swg thickness and inner dia/size 16mm complete. 63 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. ap-wcr/wc 64 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. ap-wcr/wc 65 supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) 66 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine waveinverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology completeas per specification no.ap-inv 67 supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 68 supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270v and output voltage 200-250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. 69 supplying and erecting switch disconnector fuse (sdf) switch 415v, 100a,open execution, four poleac23 a rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to is/iec 60947-3 part-1/3hrc - din type fuse, insulation voltage 1000 vfor enclosing in panel with rotary handle for on / off operation (without hrc fuse) 70 supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a,powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / cc foundation. 71 supplying, erecting & marking spmcb 0.5a to 5a, c-series with rated short - circuit breaking capacity (icn) 10kain provided distribution board as per specification no. sw-swr/mcb 72 supplying, erecting & marking spmcb 6a to 32a, c-serieswith rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 73 supplying, erecting & marking spmcb 6a to 32a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 74 supplying, erecting & marking dpmcb 6 a to 32 a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 75 supplying, erecting & marking tpmcb 6a to 32a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 76 supplying, erecting & marking tpmcb 40a to 63a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 77 supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40awith required wiring connections and lugs etc. in provided distribution board. 78 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board. 79 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63ain provided distribution board. 80 supplying&erectingtriplepole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flushmounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb 81 supplyingand erecting single pole and neutral distributionboard (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw-swr/mcbdb 82 supplying & erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb /tp mcb/fp mcb/rccb/rcbo complete erected on angle iron/gi frame. 83 supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb1 84 providing & erecting 4 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb (rate of 3 pole mccb +20% for 4 pole mccb= 5309x20%+5309=6370.80) 85 supplying and erecting cupboard for enclosing switchgears orforany other purposemadefromselected marine plywood planks 19 mm thick duly varnished/ painted from inside and from outside with brass hinges and locking arrangement with suitable lock with keys in duplicate. cupboard shall be duly grouted with suitable size of iron work in wall at the bottom. (size of cupboard 0.5x1x2+0.5x1x2+1x1x2= 4 sq.mtrs.) 86 supplyinganderectingiron, sheet metal work consisting of crcasheets, varioussectionsofiron,plates, chequeredplates,rods,bars,mspipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 50x50x4mm angle @ 3.4 kgs x 6 mtrs.= 20.40 kgs i,e 20 kgs. 87 supplying and erecting 525 v 3 phase, 50 hz., mpp type capacitor having minimum overcurrent capacity of 1.8 in,peak inrush current capacity 300 inand minimum life 150000 hourskvarbank of all polypropylenecondensers (app)withthestandard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kvarunitsofp.f. correctionforoperationon 3 phase 50 hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and providedwithterminalcoverbox completeerected onprovidediron bracketoronfloordulytestedby licensee.( original p.f=0.8 desired p.f = 0.95 for this multiplying factor is 0.421. so 0.421 x 46.440 = 19.55 i.e 10 kvar x 2= 20 kvar) 88 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 89 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al (double run) 90 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 91 supplying & erecting g.i. pipe‘a’ class 50 mmdia.erectedfor enclosingxlpearmouredcable on wall/poleas per specification no. cb-ce 92 supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 93 supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mmoutside dia. double wall corrugatedpipes (dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 94 supplying & erectingcast iron cable indicatorplate buried along with route of cable for pvc / xlpe armoured cableas per specification no. cb-cip 95 supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thickcomplete on pole/wallas per specification no. cb-sb 96 providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh-pl/opl 97 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 98 providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 99 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. ea-ep 100 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. ea-ep 101 providingpipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea-ep 102 supplying and erecting gi strip of required size used for earthing on wall and/or any other purpose with necessary gi clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsas per specification no. ea-ep.(25x3mm strip. perpole 1.5 mtrs. so for 13 poles 13nos.x1.5mtrs.= 19.5 mtrs. weight of strip @0.590kgs/mtr. so 19.50mtrs.x0.590kgs.=11.51 kgs.) 103 supplying and erecting minimum three & above star rated 1 phase, 230 v, 50 hz, submersible pump set of 1.5 kw/2hp suitable for erection on open well, pump having delivery head from 29to 7 m and discharge from 30 to 600 litres. . per minute& pipe of suction 50 mm/delivery 50 mm diameter erected with necessary h type clamps as per specification no. wp-osp 104 supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. 105 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c. submersible/centrifugal pump set up to 3 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 106 supplying & erecting carbon dioxide (co2) fire extinguisher of 4.5 kg. capacity cartridge type conform to is 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. m. s. flat with nut & bolts routed in wall complete. 107 making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (02x02x02 foundation for main control panel stand and for street light control panel 0.2x0.2x0.2mtr.=0.16 cu.mtrs.) 108 makingm- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). 109 supplying and erecting isi mark gi pipe 50 mm dia.‘b’ class at position with accessories complete as per specification no. cw-plb/gp. 110 supplying and erecting high density polythene pipe isi mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete. 111 supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. 112 supplying and erecting non return valve 50 mm dia in position made of gun metal complete. 113 lum sump provision towards service connection charges1 no.3 phase @ rs. 55000/-/per total rs.55,000/-
  • View Tender
  • Document
  • Bid Support
5 Crude Oil/Natural Gas/Mineral Fuels
image image
corporations/Associations/Others
TRN :34403921 |  10 May, 2025
Tender Value : 0
 Visakhapatnam - Andhra Pradesh
Tender for gem bids for heat exchanger tubes, low carbon steel, tubes, metallic, heat exchanger tubes, ibr heat exchanger tubes, heat exchanger tubes
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : bakelite tube
  • Carbon Nanotube Tenders ,
  • Copper Tube Spares Tenders ,
  • Carbon Tube Tenders ,
  • Tubing Set Tenders ,
  • Stay Tube Tenders ,
  • Steel Tube Tenders ,
  • Air Heater Tube Tenders ,
  • Tube Assembly Tenders ,
  • Metal Tube Tenders ,
  • Tube Metal Tenders

Get bakelite tube Tender Alert...

513227

Related Searched Keywords : bakelite tube

  • Vinayl Flooring Tenders From Maharashtra
  • Sewerage Tenders From Delhi
  • Drainage System Tenders From West-Bengal
  • Lift Irrigation Service Tenders From -Tamil-Nadu
  • Soil Work Tenders From Andhra-Pradesh
  • Rcc Roofing Tenders From Gujarat
  • Earth Filing Tenders From Karnataka
  • Piling Work Tenders From Uttar-Pradesh
  • Interlocking Tile Flooring Tenders From Rajasthan
  • Underground Sewerage Tenders From Madhya-Pradesh

Read More


Tender Document

975547

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Earth Filing Tenders
  • Borewell Tenders
  • Dismantling Tenders
  • Drilling Tenders
  • Canal Work Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App