Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Cladding Work
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of cladding-work Tenders

List of latest cladding-work Tenders in Indian Tenders. Click on any cladding-work Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for cladding-work Tenders.

Advance Search
  • All-Tenders (10)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Defence
image image
Statutory Bodies and Commissions/Committees
TRN :49054038 |  13 May, 2025
Tender Value : 0
 Siang - Arunachal Pradesh
Tender for tender for supply and construction of cook house dining hall; 1 schedule of works 2 supply and constr of chdh (or) of size 18.0 x 6.10m with 1.50m wide covered verandah, four partition walls to form two internal store rooms, doors details (d x 04, d1 x 02, d2 x 01), seven aluminium sliding windows (4x4), two turbo ventilators, false ceiling made of 30mm puf panels, wall cladding made of 50mm puf panels, roof cladding made of 0.6mm ppgi colour coated sheets and four steel trusses made of portal frame structure.main column with web-300200 x 5mm thick and flanges of 128 x 8mm thick, main rafter with web-250100x 5mm thick and flanges of 100 x 8mm thick and cantilever verandah rafter of same dimension.the four main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by z/c purlins at spacing all as given in the drawing no chdh-or-01, seven sheets attached.in addition, rear covered verandah of 18.0m x 1.8m with cantilever rafter of web-250150 x 5mm thick and flanges of 100 x 8mm thick will be provided.technical specifications as per appx a. 3 supply and constr of constr mtrl for cook house dining hall (chdh). detailed specification as per appx b. list of elect items andconstr mtrl is as per annx - i & annx - ii. 4 provn of chair writing as per tech specifications given in appx c. 5 provn ofwriting table as per tech specifications given in appx c. 6 provn of stainless steel dining chair as per tech specifications given in appx c. 7 provn of dining table as per tech specifications given in appx c. 8 provn of stainless steel table as per tech specifications given in appx c. 9 provn of water dispensor as per tech specification given in appx c. 10 supply and constr of interlocking paving blocks for pathway as per detailed specifications given as per appx d and store listas per annx - iii. 11 (a) provn of individual standalone plastic body smoke alarm with adequate provision for fixing on wall/ceiling/roof. the unit to have sensor capable of covering area >40sqm and actuating an inbuilt alarm with loudness minimum 80 db. smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery, including supply two nos of battery. (make : fire end/afo/safe guard) 12 (b) provn of individual standalone plastic body heat alarm with adequate provision for fixing on wall/ceiling/roof. the unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery, including supply two nos of battery. (make : fire end/afo/safe guard) 13 (c) fire ball extinguisher of 1.3 kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. the unit to be maintainance free, non toxic, envoronment friendly and suitable for all type of fires. (make : fire end/afo/safe guard/kanex/fire stop/elide or equivalent)
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
3 Power Plant
image image
corporations/Associations/Others
TRN :49056804 |  23 May, 2025
Tender Value : 18.27 Lacs
 Prayagraj - Uttar Pradesh
Tender for tender for annual civil & electrical m&r work for residential building situated at 20-clive road hydel colony, prayagraj - earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for all kinds of soil. 2 supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 3 surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. for all kinds of soil. 4 excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 5 providing and laying in position cement concrete of grade 1:1½:3 (1 cement: 1½ coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 6 providing and laying in position cement concrete of grade1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 7 providing and laying in position cement concrete of grade 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 8 providing and laying cement concrete 1:1½:3 (1 cement: 1½ coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 9 providing and fixing up to floor five level precast cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering complete. 10 providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 11 extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 12 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 13 providing and laying in positiongrade 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 14 providing and laying in positiongrade 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 15 reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 16 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 17 centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete 18 centering and shuttering including strutting, propping etc. and removal of form for walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 19 centering and shuttering including strutting, propping etc. and removal of form forsuspended floors, roofs, landings, balconies and access platform 20 centering and shuttering including strutting, propping etc. and removal of form for shelves (cast in situ) 21 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers 22 centering and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts 23 centering and shuttering including strutting, propping etc. and removal of form for stairs, (excluding landings) except spiral-staircases 24 centering and shuttering including strutting, propping etc. and removal of form for spiral staircases (including landing) 25 centering and shuttering including strutting, propping etc. and removal of form for small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 26 centering and shuttering including strutting, propping etc. and removal of form for small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 27 centering and shuttering including strutting, propping etc. and removal of form for weather shade, chajjas, corbels etc., including edges 28 centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 29 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 30 mild steel and medium tensile steel bars for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 31 mild steel and medium tensile steel bars for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 32 smooth finishing of the exposed surface of r.c.c. work with 6 mm thick cement mortar 1:3 (1 cement : 3 fine sand). 33 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 34 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand) 35 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand) 36 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) 37 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. cement mortar 1:4 (1 cement :4 coarse sand) 38 providing and fixing 18 mm thick granite stone slab of colour black, cherry/ruby red gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (area of slab over 0.50 sqm) 39 providing edge moulding to 18 mm thick granite workcounters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer-in-charge. 40 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 41 providing and fixing plywood 4 mm thick, one side decorative veneer conforming to is: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : 42 providing and fixing 4mm thick coir veneer board, isi marked is : 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 43 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 44 providing second class teak wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 45 providing and fixing 2nd class teak wood size 50x12 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 46 providing and fixing second class teak wood panelled or panelled and glazed 30 mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of engineer-in-charge. (note:- butt hingesand necessary screwsshall be paid separately) 47 providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 48 providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 49 providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned and chemically treated hollock wood) 50 providing and fixing35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned selected planks of sheesham wood) 51 providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned selected planks of sheesham wood) 52 providing and fixing30mm thick panelled or panelled & glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(second class teak wood including isi marked anodised aluminium butt hinges with necessary screws) 53 providing and fixing isi marked 35mm thick flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 54 providing and fixing isi marked 30mm thick flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 55 providing and fixing isi marked 35mm thick flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 56 extra for providing and fixing flush doors with on one side only decorative veneering instead of non decorative isi marked flush door shutters conforming to is: 2202 (part i) 57 providing and fixing 12mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 58 providing and fixing 20mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 59 providing and fixing 25mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 60 providing and fixing 20mm dia (heavy type) nickel plated m.s. pipe curtain rods with nickel plated brackets : 61 providing and fixing 25mm dia (heavy type) nickel plated m.s. pipe curtain rods with nickel plated brackets : 62 providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 63 providing and fixing 125x65x2.12 mm isi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 64 providing and fixing 100x58x1.90 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 65 providing and fixing 75x47x1.70 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 66 providing and fixing 50x37x1.50 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 67 providing and fixing 150 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 68 providing and fixing 125 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 69 providing and fixing 100 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 70 providing and fixing 250x16 mm isi marked oxidised m.s. sliding door bolts with nuts and screws etc. complete (copper oxidised as per is 1378) 71 providing and 250x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 72 providing and 200x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 73 providing and 150x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 74 providing and 100x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 75 providing and fixing isi marked 85x42 mm oxidised m.s. pull bolt lock conforming to is : 7534 with necessary screws bolts, nut and washers etc. complete (copper oxidised as per is 1378). 76 providing and fixing 125 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 77 providing and fixing 100 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 78 providing and fixing 75 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 79 providing and fixing 150 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 80 providing and fixing 115 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 81 providing and fixing 90 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 82 providing and fixing 300 mm (weighing not less than 330 grams) oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete (copper oxidised as per is 1378) 83 providing and fixing 125mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 84 providing and fixing 100mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 85 providing and fixing 75mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 86 providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 87 providing and fixing triple strip vertical type magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 88 providing and fixing double strip (horizontal type) magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 89 providing and fixing factory made upvc door frame made of upvc extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. the hinge side vertical of the frames reinforced by galvanized m.s. tube of size 19 x 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of engineer- in-charge (extruded section profile size 48x40 mm) 90 providing and fixing factory made upvc door frame made of upvc extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. the hinge side vertical of the frames reinforced by galvanized m.s. tube of size 19 x 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of engineer- in-charge (extruded section profile size 42x50 mm) 91 providing and fixing 12 mm thick fire retardant plywood conforming to is: 5509 panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 92 providing and fixing cup board shutters 25 mm thick, with pre-laminated flat pressed three layer particle board or graded wood particle board is: 12823 marked, exterior grade (grade l type ll), having one side decorative lamination and other side balancing lamination, including iind class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the engineer-in-charge 93 providing and fixing aluminum u beading of required size to pre-laminated/flush door shutter, including fixing etc. complete as per direction of engineer-in-charge. 94 providing and fixing casement handle made of zinc alloyed (white powder coated) for upvc casement window with necessary screws etc. complete. 95 providing and fixing zinc alloyed (white powder coated) touch lock for upvc sliding window with necessary screws etc. complete. 96 providing and fixing steel roller for upvc sliding window with necessary screws etc. complete. 97 providing and fixing steel roller for upvc sliding door with necessary screws etc. complete. 98 providing and fixing steel (white power coated) crescent lock for upvc sliding window/ door with necessary screws etc. complete. 99 providing and fixing 18mm thick both sides pre-laminated cement bonded wood particle board as per is : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of engineer-in-charge (note: fittings to be paid separately). 100 providing and fixing 6mm thick both sides pre-laminated cement bonded wood particle board as per is : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of engineer-in-charge. 101 providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed bwp grade marine ply as per is 710 of approved brand including 2mm thick pvc edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of engineer-in-charge.(payment of providing and fixing auto closing hinges shall be paid separately) 102 structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 103 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of t-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 104 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.(using m.s. angels 40x40x6 mm for diagonal braces) 105 providing and fixing stainless steel ( grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 106 providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of engineer-in-charge. 107 brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar with 1:6 (1cement : 6 coarse sand) including filling the joints with same mortar, with common burnt clay non modular bricks: 108 dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with jamuna sand, with common burnt clay non modular bricks. 109 40 mm thick with 20 mm nominal size stone aggregate cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 110 18 mm thick cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 111 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 112 cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. 113 25 mm thick kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 114 deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. 115 fixing glazed/ ceramic/ vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (water based) conforming to is: 15477, in average 3mm thickness. 116 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 117 providing and fixing 1st quality ceramic glazed floor tiles conforming to is : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 118 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to is : 15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 119 providing and laying vitrified floor tiles size 600x600 mm(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. 120 providing 1 mm thick with zinc coating not less than 275 gm/ m² corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 121 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 122 providing & fixing 0.56 mm, aluminium color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm at all heights, levels and locations colour finish aluminium alloy roofing sheets of alloyis designation31500, temper hx8 conforming to is 737 and dimensions as per is code 2676 with characteristics of good formability and corrosion resistance. the profile sheets shall be fixed to truss members in slope or required pitch or curvature with hex cap headed self drilling/tapping stainless steel screws m6, 50 mm long with 3 mm epdm seal washer etc. all inclusive of labour, scaffolding, t&p and sundries etc. complete as per directions of the engineer-in-charge. (cost of truss/frame work shall be paid separately). 123 providing and fixing precoated/mill finish aluminium ridges plain (500- 600mm) of pre-coated colour or mill finishaluminium roofing accessories in 0.71 mm thickness ,alloy 31500 (is designation) [aluminium alloy (aa) 3004 (iso designation)]for color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping ss screws of size 6 x 50mm with 3mm thick epdm seal and ss plain washer complete : 124 providing 10 mm thick plaster of paris (gypsum anhydrous) flat surfaces ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 125 12.5 mm thick fully perforated gypsum board tile made from plasterboard having glass fibre conforming to is: 2095 part i, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an nrc (noise reduction coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 126 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) 127 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) 128 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) 129 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) 130 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 131 neat cement punning. 132 distempering with 1st quality acrylic distemper (ready mixed) new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than50 gram/litre of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 133 finishing walls for new work (two or more coats applied @ 3.84 kg/10 sqm) with water proofing cement paint of required shade : 134 finishing walls for new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) with acrylic smooth exterior paint of required shade : 135 finishing walls for new work (two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. with ready mixed premium acrylic emulsion paint (company depot tinted) having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. 136 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 137 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 138 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) 139 painting (two or more coats) on 100mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 140 painting (two or more coats) on 150mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 141 painting two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 142 polishing on new wood work with ready mixed wax polish of approved brand and manufacture : 143 lettering with black japan paint of approved brand and manufacture 144 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 145 distempering for old work (one or more coats) with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour 146 applying priming coats with water thinnable cement primer on wall surface having voc content less than 50 grams/litre of approved brand and manufacture. 147 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of engineer-in-charge. 148 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 149 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 150 polishing on old wood work with ready made wax polish of approved brand and manufacture : 151 painting (one or more coats) with black japan paint of approved brand and manufacture to give an even shade. 152 finishing walls for old work (two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface with acrylic smooth exterior paint of required shade : 153 repairs to plaster of thickness 12 mm to 20 mm with cement mortar 1:4 (1 cement : 4 fine sand) in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge. 154 fixing door chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge. 155 fixing chowkhat in existing opening in brick/ rcc wall with dash fasteners/chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including cost of dash fasteners/ chemical fastener. 156 making the opening for door/ window/ clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of engineer-in-charge. 157 renewing float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) with putty and nails wherever necessary including racking out the old putty: 158 renewing float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) with putty and nails wherever necessary including racking out the old putty: 159 renewal of old putty of glass panes (length) 160 refixing old glass panes with putty and nails 161 fixing old glass panes with wooden fillets (excluding cost of fillets) 162 renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 163 pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 164 providing and fixing 20 mm diameter. brass curtain rods ofwall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 165 repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of engineer-in-charge. 166 cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of engineer-in-charge. 167 disconnecting damaged overhead/terrace pvc water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of engineer-in-charge. 168 providing & fixing orissa pattern w.c pan of size 580x440 mm white vitreous china water closet squatting pan (indian type) along withs or p trap including dismantling of old wc seat and s or p trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of engineer-in charge. 169 dismantlingw.c.pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in-charge. 170 dismantling 15 to 40 mm dia g.i. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of engineer-in-charge.(a) internal work- exposed on wall 171 taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the engineer-in-charge. 172 demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of engineer- in-charge. 173 demolishing nominal cementconcrete 1:3:6 or richer mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 174 demolishing nominal cementconcrete 1:4:8 or leaner mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 175 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer - in- charge. 176 demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 177 removing mortar from bricks in from brick work in cement mortar and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): 178 dismantling doors, windows and clerestory windows (steel or wood) shutter of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 179 dismantling doors, windows and clerestory windows (steel or wood) shutter of area beyond 3 sq. metres including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 180 taking out doors, windows and clerestory window shutters (steel or wood) of area 3 sq. metres and belowincluding stacking within 50 metres lead : 181 taking out doors, windows and clerestory window shutters (steel or wood) of area beyond 3 sq. metres including stacking within 50 metres lead : 182 dismantling for thickness of tiles 10 mm to 25 mmwork in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 183 dismantling for thickness of tiles above 25 mm and up to 40 mmwork in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 184 demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : 185 dismantling g.s. sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 metres lead of: 186 dismantling asbestos cement sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 metres lead of: 187 dismantling tiled roofing with battens, boarding etc. complete includingstackingofserviceablematerialanddisposalofunserviceable material within 50 metres lead. 188 dismantlingbarbedwireorflexiblewireropeinfencingincludingmaking rolls and stacking within 50 metres lead. 189 dismantling40 mm thick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 metres lead : 190 dismantling40 mm to 75mmthick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 metres lead : 191 dismantling cement asbestos or other hard board ceiling or partition wallsincludingstackingofserviceablematerialsanddisposalof unserviceable materials within 50 metres lead. 192 dismantling of flushing cistern of all types(c.i./pvc/vitrious china) includingstackingofusefulmaterialsnearthesiteanddisposalofunserviceable materials within 50 metres lead. 193 dismantling old plaster or skirting raking out joints and cleaning the surfaceforplasterincludingdisposalofrubbishtothedumping ground within 50 metres lead. 194 dismantlingaluminium/gypsumpartitions,doors,windows,fixed glazing and false ceiling including disposal of unserviceable material andstackingofserviceablematerialwithin50metersleadas directed by engineer-in-charge. 195 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping groundorasapprovedbyengineer-in-charge,beyond50minitial lead, for all leads including all lifts involved. 196 cuttingroadandmakinggoodthesameincludingsupplyofextra quantities of materials i.e. aggregate, moorum screening, red bajri and labour (required.bituminous portion) 197 paintingroadsurfacemarking for new work (two or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to is : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 198 paintingroadsurfacemarking for old work (one or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to is : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 199 taking out existing cc interlocking paver blocks from footpath/ central verge,includingremovalofrubbishetc.,disposalofunserviceable materialtothedumpingground,forwhichpaymentshallbemade separately and stackingof serviceable materialwithin 50metre lead as per direction of engineer-in-charge. 200 layingoldcementcocreteinterlockingpaverblocksofanydesign/ shapelaidinrequiredline,level,curvature,colourandpatternover and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer- in-charge. (old cc paver blocks shall be supplied by the department free of cost). 201 providing and laying 80mmthickc.c.paverblockofm-35gradewith approved colour design and pattern.factory made chamfered edge cement concrete paverblocksinfootpath,parks,lawns,drivewaysorlighttraffic parkingetc,ofrequiredstrength,thickness&size/shape,madeby tablevibratorymethodusingpumould,laidinrequiredcolour& patternover50mmthickcompactedbedof sand,compactingand properembedding/layingofinterlockingpaverblocksintothesand beddinglayerthroughvibratorycompactionbyusingplatevibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. completeall as per direction of engineer-in-charge. 202 providing andfixingwhitevitreouschinaorissapatternw.c.panofsize 580x440 mm with integral type foot rests waterclosetsquatting pan(indian typew.c. pan)with100mmsandcastironporstrap,10litrelowlevel whitep.v.c.flushingcistern,includingflushpipe,withmanually controlleddevice(handlelever)conformingtois:7231,withall fittingsandfixturescomplete,includingcuttingandmakinggood the walls and floors wherever required: 203 providing and fixing w.c. pan with isi marked white solid plastic seat and lid white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard makeandmosquitoproofcouplingofapprovedmunicipaldesign complete,includingpaintingoffittingsandbrackets,cuttingand making good the walls and floors wherever required : 204 providingandfixing oneurinalbasinwith5litrewhitep.v.c.automaticflushing cistern whitevitreouschinaflatbackorwallcorner typelippedfronturinalbasinof430x260x350mmand 340x410x265 mm sizes respectively with automatic flushing cistern withstandardflushpipeandc.p.brassspreaderswithbrass unions and g.i clamps complete, including painting of fittings and brackets,cuttingandmakinggoodthewallsandfloorswhereverrequired : 205 providingandfixingwhitevitreouschinawashbasinsize550x400mm with a pair of 15 mm c.p. brass pillar taps washbasinwithc.i.brackets,15mmc.p. brasspillartaps,32mmc.p.brasswasteofstandardpattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 206 providing and fixing wash basin with c.i. brackets, 15 mm dia cp brasssingleholebasinmixerofapprovedqualityandmake, including painting of fittings and brackets, cutting and making goodthe walls wherever required:- (a)white vitreous china wash basin size 550x400 mm with a 15 mm cp brass single hole basin mixer 207 providingandfixingwhitevitreouschinapedestalforwashbasin completelyrecessedatthebackforthereceptionofpipesand fittings. 208 providing and fixing 610x510 mm bowl depth 200 mm stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (kitchen sink without drain board) 209 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer - in - charge. 210 providing and fixing 10 litre capacity - white p.v.c. low level flushing cistern with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete. 211 providing and fixing 10 litre (full flush) capacity-white controlled flush, low level cistern made of vitreous china with all fittings complete. 212 providing and fixing g.i. inlet connection for flush pipe connecting with w.c. pan. 213 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer-in-charge. 214 providing and fixing15 mm nominal dia cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge. 215 providingandfixing 32mm diaflexible pipe p.v.c.wastepipeforsinkorwashbasin including p.v.c. waste fittings complete. 216 providing and fixing 100 mm sand cast iron grating for gully trap. 217 providingandfixinginposition25mmdiametermosquitoproofcoupling of approved municipal design. 218 providing and fixing 600x450 mm beveled edge mirror of superior glass(ofapprovedquality)completewith6mmthickhardboard ground fixed to wooden cleats with c.p. brass screws and washerscomplete. 219 providing andfixing circular shape 450 mm dia mirrorofsuperiorglass(ofapprovedquality)andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : 220 providing andfixing 600x120x5 mmglass shelfwith edges round off, supported on anodised aluminium angle frame with c.p. brass bracketsandguardrailcompletefixedwith40mmlongscrews, rawl plugs etc., complete. 221 providing and fixing c.p. brass toilet paper holder : 222 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 223 providing and fixing ptmt towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 224 providing and fixing ptmt 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 225 providing and fixing ptmt 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 226 providing and fixing ptmt shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. 227 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 228 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 229 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 230 providing and fixing 25 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 231 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 232 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 233 providing and fixing 25 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 234 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 235 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 236 providing and fixing 25mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 237 providing and fixing 32mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 238 providing and fixing 40mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 239 providing and fixing 50mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 240 providing and fixing 15 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 241 providing and fixing 20 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 242 providing and fixing 25 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 243 providing and fixing 15 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 244 providing and fixing 20 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 245 providing and fixing 25 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 246 providing and fixing 32 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 247 providing and fixing 40 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 248 providing and fixing 50 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 249 providing and fixing 25 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 250 providing and fixing 20 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 251 providing and fixing 32 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 252 providing and fixing 15 mm nominal bore ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 253 providing and fixing 20 mm nominal bore ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 254 providing and fixing 15mm norminal bore 45 cm length uplasticised pvc connection pipe with brass unions : 255 providing and fixing 20mm norminal bore 45 cm length uplasticised pvc connection pipe with brass unions : 256 providing and fixing 100 mm diameter c.p. brass shower rose with 15 or 20 mm inlet : 257 providing and fixing 150 mm diameter c.p. brass shower rose with 15 or 20 mm inlet : 258 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 259 providing and fixing 15 mm nominal bore c.p. brass bib cock of approved quality conforming to is:8931 : 260 providing and fixing 15 mm nominal bore c.p. brass long nose bib cock of approved quality conforming to is standards and weighing not less than 810 gms. 261 providing and fixing 15 mm nominal bore c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 262 providing and fixing 15mm nominal bore c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 263 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 264 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 265 providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to is: 1868, minimum anodic coating of grade ac 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer-in-charge. (glazing, paneling and dash fastenersto be paid for separately) :(for fixed portion) 266 providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer-in-charge. (glazing, paneling and dash fastenersto be paid for separately) :(for fixed portion) 267 providing and fixing glazing with float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 268 providing and fixing glazing with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 269 providing and fixing glazing with float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 270 providing and fixing with stainless steel cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to is : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer-in-charge. 271 providing and fixing with brass cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to is : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer-in-charge. 272 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours.(b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 273 providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of fibre glass cloth when the first layer is still green. overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. this will be allowed to air cure for 4 hours followed by water curing for 48 hours. the entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (for the purpose of measurement the entire treated surface will be measured.) 274 providing & applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of engineer-in-charge. 275 providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of rcc structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. after cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. over the primed surface swellable type water stop tape shall be placed. the work shall be carried out all complete as per specification and the direction of the engineer-in-charge. the product performance shall carry guarantee for 10 years against any leakage. 276 providing and fixing with15mmthick fullyperforatedsquare/buttedgelightweightcalcium silicate panels/ tiles in position wall panelling at all heights with integral densified calcium silicatepanels/tilesofsize595x595mm,havingnrc(noisereductioncoefficient)of0.50 (minimum) as per is 8225:1987, light reflectance of 85% (minimum). non combustible as per bs:476 (part-4), fire performance as per bs:476 (part 6 &7), humidity resistanceof 100%,thermalconductivity<0.043w/mk asperastm518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mmthickpressedsection(galvanizing@120gramspersqmincludingbothsides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor andceilingchannel sectionofsize50x32mfixedtothefloorandsoffitat600mm centersusing12mmdia,50mmlongwedgetypeexpandedzincalloy dashfastnerwith 10mm bolt. this same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. glasswool of 50mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to bescrew fixed withselftapping panheadnickel coatedmild steelscrewsofsize13x3.2mmon tothisgridleavingan evengroove of1 mm betweenthepanels. the joints betweenthepanelsaretobedulyjointedandfinishedusingrecommendedjointing calcium silicate based compound and fiber joint tape roll 50mm wide(90 metre )roll and twocoatsofprimersuitableforpanellingaspermanufacturersspecificationasper direction of engineer-in-charge all complete. 277 providing and fixing with 16 mm thick beveled tegular mineral fibre false ceiling tile (nrc 0.55 to 0.6 mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%,lightreflectance=85%,thermalconductivityk=0.052-0.057w/mk,fire performance as per (bs 476 pt - 6 &7)in true horizontal level suspended on interlocking t- grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm)comprisingofmaintrunnersof15x32mmoflength3000mm,crosstofsize 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length600mm toform gridmoduleofsize 600x600mm suspendedfrom ceiling using galvanizedmildsteelitem(galvanised@80gsm)50mmlong8mmouterdiameterm-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l- shapeleveladjusterofsize85x25x2mm,spacedat1200mmcentretocentrealong main‘t’.thesystemshouldrestonperipherywalls/partitionswiththehelpofgi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry walls.s. screws. the exposed bottom portion of all t-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. the work shall be carriedoutasperspecifications,drawingsandasperdirectionsoftheengineer-in- charge. 278 providingandfixingharddrawnsteelwirefabricofsize75x25mmmeshorother suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of l shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge. 279 fillingofjointsbetweenrccplinthbeam/floorslabandwallpanelofexternalwalls, toilet / bath room / wet areas walls on all floor and parapet wall over roof slab, stair case headroomatthetimeoferectionofgfrgpanelswithgroutrw/equivalentsealant compound after the erection of panelbeforethe infill of concrete in panel cavities and fine finish. this applies for all horizontal and vertical joints between gfrg wall and slab panels. 280 waterproofingtreatmentofverticaljoints(ofexternalsideandinternalside)between doorframe,window&ventilatorframes(onallfoursides)ofouterwalloverthe zycosil/equivalent & zycoprime/equivalent solution already applied (before the installation of door / window / ventilator frames in position) and fine finish with grout rw/equivalent. 281 waterproofingtreatmentofrccsunshadewith zycosil/equivalentwaterproofing solution(1litreofzycosil/equivalent&20litresofwaterstirredfirst&2litresof zycoprime/equivalent addedandstirred (total23litres))till itmeetsthesaturationlevel and testing as per rilem or bywater drops test in which water drops do not absorb but drops remain or rolls. 282 in-filling / sealing of joint between rcc lintel cum sunshade and wall (on external side) in all floors by pushing in grout rw/equivalentin paste form and coving 20 mm x 20 mm after applying a coat of zycosil/equivalent & zycoprime/equivalent solution before cement plastering of top, bottom and sides of rcc sunshade. 283 concreteworkwith40mmgaugebrickballastobtainedfrombreaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in csi no. 5.01 includingcost of all labour, materials, t&p etc required for proper completion of work. 284 brickworkinfoundation&plinthwitholddismantled bricks(suppliedby departmentfreeofcost)andcoarsesand mortarin1:6includingsupply ofallothermaterials,labour,removingmortar&cleaningofold&usedbricks,t&p etc complete. 285 supply and filling brick bat in soak pit including all labour,material and t&petc complete. (for 01 soak pit) 286 supplying & fixing 24 gauge annodized aluminium sheet of approved qualityincludingcutting,wastageandfixingthesameoverthewooden door shutters with nails with all material, labour and t&p 287 providingandfixinginplaceafullheightstoragecabinet450mmdeep made with19 mm thick isi marked plyborad, allinterior surfaces to finishedwithpastingof0.8mmthickmicaandallexteriorsurfacestobe finshed with pasting of 1 mm thick mica of texture and colour as approved byengineerinchargeincludingalllabour,t&p,otheritemslike(butnot limitedto)fevicol,nailsscrews,higes,sliders,doorhandles,multipurpose lockofgodrejorequivalentrateetc.requiredforpropercompletionof works, to be measured interms of front area only. 288 providingandfixingfullheightpartitionwith02nos12mmthickisi marked ply board, all surfaces to finished withf 1 mm thick mica of texture andcolourasapprovedbyengineerinchargeandfixedinpolishedteak woodincludingalllabour,t&p,otheritemslike (butnot limitedto) fevicol, nailsscrews,hinges,sliders,doorhandles,multipurposelockofgodrejor equivalent rate etc. required for proper completion of works, to be measured interms of front area only 289 providingandfixing12mmthickframelesstoughenedglassdoorshutter ofapprovedbrandandmanufacture,includingprovidingandfixingtop& bottom pivot & double acting hydraulic floor spring type fixing arrangement ,doorhandle,lockandstopperetcandmakingnecessaryholesetc.for fixingrequireddoorfittings,allcompleteasperdirectionofengineer-in- charge 290 supply and fixing 6mm thick polycarbonate multiwall sheet ,fixing in position with j or u bolts 10 mm. dia with g.i. limpet & bitumen washers including supply of all materials, labour,wastage. and t&p etc. required for proper completion of the work. 291 providing (12x15) mm section groove in plasterincluding all material, labour andt&p etc. required for proper completion of the work.csi no.11.16 292 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cccsi no.12.26 293 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cc csi no. 12.28 294 dismantling ofdry b.o.e. floor and proper stacking of dismantled bricks as per direction of e/c. up to 60 m lead. 295 dismantling and re-laying of dry b.o.e. floor including cost of all labour and t&p required forproper completion of work.(labour rates only) 296 cleaning panes of glass with spirit of caustic soda including supply of all materials,labour and t&p etc.required for proper completion of the work. 297 cleaning of septic tank including disposal of waste out side the uppcl area as per direction of the engineer-in-charge including cost of all labour,t&p etc.required for proper completion of the work. 298 cleaning and opening of chocked w.c./ bath / kithchen pipe line including opening and refixing of chamber cover including washing etc. complete.(analysis based on nbo - 11 25.020. 299 s/laying chicken mesh of (20 mm.)hexagonal heavy quality over roofs of joints of roof as per direction of the engineer - in - charge. 300 cleaning of existing pipe line of different dia. ranging from 4 to 2 dia. including digging trenches and refilling, opening of pipes, cleaning of pipes, cutting, threading, if required fixing and including making good the road, wall etc as directed by the engineer i/c. 301 cleaning of existing water pipe line of different dia up to 2 dia including digging trenches and refilling,opening and cleaning of pipes,cutting,threading,if required fixing and including making good the road and wall etc. as directed by the engineer in charge. 302 cleaning of r.c.c. over head tank up to capacity of one lac. liters and chlorinating with bleaching power mixed to water as per direction of engineer - in - charge complete. 303 supply and mixing bleaching powder in over head tank as required or as directed by engineer - in - charge. 304 attending to petty maintenance service like plumbingservice,welder service, mansion service and carpenter servicerequired as below. (job attending by one no. plumber/welder/mason /carpenter with oneno. helper per hour or part of an hour.) 305 cleaning and sweeping of roof of residence as and when requiredincluding uprooting of rank vegetation and disposal of thegarbage upto 50 m. 306 providing and fixing of 150 mm dia pvc pipeof 6 kg/sqcmwith special such as tee, bend, socket, elbow etc including supply of all labour,material,t & p etc complete required for proper completion of work. 307 providing and laying 75 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 308 providing and laying 90 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 309 providing and laying 110 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 310 making arrangement for sweeping, cleaning of road, lanes in back of houses,collecting refuse of bushes & unwanted plants, vegetations etc. & disposal of all rubbish, materials industbins inside the colony area with engaging atleast one number of sweepers including all labour, t&p,etc.required for completion of work as directed by e/i. 311 making arrangement for sweeping, cleaning of ee,ecd(d), georgetown ,prayagraj office rooms, cleaning of dustbin, toilets , dusting of almirahs,tables etc. using phenyle,dusting cloth etc. and disposal of waste outside office premise in municipal dustbinswith engaging sufficient number ofsweepersincluding all labour, t&p,etc.required for completion of work as directed by e/i.(nsi)(consumable items as phenyle,dusting cloth ,brooms etc shall be provided by the department free of cost.) 312 cleaning of main drain or width more than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the e/i. including cost of all labour, t&p etc. required for completion of the work. (csino.20.14) 313 cleaning of main drain or width less than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the e/i. including cost of all labour, t&p etc. required for completion of the work. (csino.20.15) nsi sl. no.63 314 operation of tube well daily by a suitable experienced operator continously or in different intervals as per program as per program fixed by engineer-in-charge including opening and closing of valves,changing of fuse wire etc. as requrird for proper running of tube well. (nsi) 315 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required..group c 316 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet 317 supplying and fixing of 20 mm of medium class pvc conduit along with accessories in surface/recess including junction box, cutting the wall and making good the same in case of recessed conduit as required. 318 supplying and fixing of 25 mm of medium class pvc conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required. 319 wiring for circuit/ submain wiring with 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 320 wiring for circuit/ submain wiring with 2 x 4 sq. mm + 1 x 4 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 321 wiring for circuit/ submain wiring with2 x 6 sq. mm + 1 x 6 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 322 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required . 323 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 324 supplying and fixing 5 amps to 32 amps rating,single pole, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 325 supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 326 supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 327 supplying and fixing 4 way (4 + 12), double door, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 328 supplying and fixing of 4 way (4 + 12), double door surface/ recess mounting, vertical type, 415 volts, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally used where 3 phase outlets are required.) 329 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit along with 1 no 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 330 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (75mmx75mm) 331 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required.3 module (100mmx75mm) 332 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 4 module (125mmx75mm) 333 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 6 module (200mmx75mm) 334 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 8 module (125mmx125mm) 335 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 12 module (200mmx150mm) 336 supplying and drawing following 3 x 2.5 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 337 supplying and drawing following 3 x 4 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.(dsr e&m 2022 1.17.21) 338 rewinding of burnt ceiling fan with approved copper wire including cost of all materials, labour and t&p etc. complete (burnt wirewill not be taken back.) 339 greasing of ceiling fan after cleaning the bearing and shaft withoil / petrol and its testing. 340 supply and fixing of led tube light batten fitting suitable for up to 1 x 22 watt led tube light on surface complete in all respect.(csi no. 28.41) 341 supply of 9 watt led bulb make philips, syska, bajaj etc or its equivalent as directed by e/i. 342 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min, 350 rpm (tolerance as per is: 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required.(dsr e&m 2022 19.1) 343 supply and fixing of 5 blade exhaust fan ventile air dx 225 mm of havellsor equivalent make including all material, t&p etc required for proper completion of work as approved by engineer in charge.(csi no. 28.38) 344 supply and fixing of 3 blade wall fan ofhavells platina 400 mm or equivalent including all material, t&petc required for proper completion of work as approved by engineer in charge.(csi no. 28.37)
  • View Tender
  • Document
  • Bid Support
4 Housing Urban And Rular Development
image image
Government Departments
TRN :49056962 |  29 May, 2025
Tender Value : 5.80 Crore
 Gaya - Bihar
Tender for tender for special repair work at jnv gaya-i (bihar) - school building 2 structural repair & retrofitting 3 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 4 50mm average thickness 5 25 mm average thickness 6 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 7 bars upto 12 mm diameter 8 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 9 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 10 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in grade m 25 with cement content not less than 330 kg per cum 12 50mm thick in grade m 25 with cement content not less than 330 kg per cum 13 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 14 expansion joint treatment 15 providing and fixing of expansion joint system related with floor location as per drawings and direction of engineer-in-charge. the joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per astm b221-02. the system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. system shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. the cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. the self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. provision of moisture barrier membrane in the joint system to have watertight joint is mandatory requirement all as per the manufactures design and as approved by engineer -in- charge. (material shall confirm to astm 6063). 16 floor joint of 100 mm gap 17 providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of engineer-in- charge. the joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per astm b221- 02. the material shall be such that it provides an expansion joints systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office buildings & complexes with no slipping down tendency amongst the components of the joint system. the joint system shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (material shall confirm to astm 6063). 18 wall joint of 100 mm gap 19 providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of engineer-in-charge. the joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per astm b221-02. the system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. system shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. the cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. the self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. the joint system shall resists damage or deterioration from the impact of falling ice, exposure to uv, airborne contaminants and occasional foot traffic from maintenance personnel. provision of moisture barrier membrane in the joint system to have water tight joint is mandatory requirement. (material shall confirm to astm 6063.) 20 roof joint of 100 mm gap 21 repairs to roof 22 repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (dr. fixit make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge.with cement mortar 1:4 (1 cement: 4 coarse sand) 23 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 24 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 25 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 26 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 27 asbestos cement sheet 28 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 29 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 30 repair to toilets + plumbing works 31 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 32 for thickness of tiles 10 mm to 25 mm 33 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 34 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 35 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 36 providing and filling of cinder in sunken portion. 37 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 38 75 to 80 mm dia pipe 39 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 40 15 mm to 40 mm nominal bore 41 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 42 up to 150 mm diameter 43 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 44 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 45 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 46 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 47 rectangular manhole 90x80 cm and 45 cm deep 48 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 49 110 mm diameter 50 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 51 a) coupler 52 110 mm 53 b) bend 87.5° 54 110 mm bend 55 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 56 75 mm diameter pipes 57 100 mm diameter pipes 58 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 59 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 60 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 61 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 62 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 63 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 64 a) 32mm dia (for wash basin) 65 b) 40mm dia (for sink and urinal) 66 providing & fixing c.p. brass waste coupling for pvc waste pipe. 67 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 68 110 mm dia (wall thickness - 3.2 to 3.8 mm) 69 75 mm dia (wall thickness - 3.2 to 3.8 mm) 70 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 71 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 72 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 73 p-trap type floor trap 110 x 75 mm 74 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 75 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 76 providing and fixing 100 mm sand cast iron grating for gully trap. 77 providing & fixing soil, waste and vent pipes. 78 a) 100mm dia centrifugally cast iron s & s pipe. 79 b)75mm dia centrifugally cast iron s & s pipe. 80 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 81 a) for 100mm dia pipe. 82 b) for 75mm dia pipe. 83 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 84 a) 100mm 85 sand cast iron s&s as per is - 3989 86 b) 75mm 87 sand cast iron s&s as per is- 3989 88 providing and fixing plaincast iron s & s sanitary bend. 89 a) 100mm 90 sand cast iron s&s as per is - 1729 91 b) 75mm 92 sand cast iron s&s as per is - 3989 93 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 94 a) 100x100x100mm 95 b) 75x75x75mm 96 providing and fixingcast iron terminal guard. 97 a) 100mm 98 b) 75mm 99 providing & fixingcast iron coller. 100 a)100 mm 101 sand cast iron s&s as per is - 3989 102 b)75mm dia. 103 sand cast iron s&s as per is - 3989 104 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 105 a) 100mm 106 b) 75mm 107 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 108 a) 100mm inlet & 75mm outlet. 109 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 110 providing and fixing ptmt urinal cock of approved quality and colour. 111 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 112 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 113 15 mm nominal outer dia pipes 114 20 mm nominal outer dia pipes 115 25 mm nominal outer dia pipes 116 32 mm nominal outer dia pipes 117 providing and fixing brass stop cock of approved quality. 118 15 mm nominal bore 119 providing and fixing gun metal gate valve with wheel of approved quality. 120 a) 25mm dia nominal bore 121 b) 32mm dia nominal bore 122 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 123 a) 25mm. nominal bore 124 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 125 a) 15mm nominal bore 126 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 127 a) 15mm nominal bore 128 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 129 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 130 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 131 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 132 providing & fixing cp brass bib cock of approved quality conforming to is 8931 133 a) 15mm nominal bore 134 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 135 a) 15mm nominal bore 136 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 137 15mm nominal bore 138 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 139 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 140 25mm nominal bore, weighing not less than 62 gms 141 cutting holes up to 30x30 cm in walls including making good the same: 142 with common burnt clay f.p.s. (non modular) bricks 143 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 144 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 145 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 146 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 147 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 148 repair to plaster and plinth protection 149 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge.nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 150 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 151 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 152 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 153 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 154 with cement mortar 1:4 (1cement: 4 coarse sand) 155 12mm cement plaster of mix : 156 1:6 (1 cement : 6 course sand) 157 6mm cement plaster to ceiling of mix : 158 1:3 ( 1 cement : 3 fine sand) 159 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 160 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 161 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 162 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 163 old work (one or more coats) 164 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 165 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 166 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 167 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 168 repairs to door / windows 169 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 170 of area 3 sq. metres and below 171 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 172 of area 3 sq. metres and below 173 renewing glass panes, with putty and nails wherever necessary including racking out the old putty:float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 174 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 175 35 mm thick including isi marked stainless steel butt hinges with necessary screws 176 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 177 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete 178 fixed to steel windows by welding 179 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 180 300 mm weighing not less than 200gms. 181 250 mm weighing not less than 150gms. 182 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 183 100x58x1.90 mm 184 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 185 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 186 300 x 10mm 187 200 x 10mm 188 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 189 125 mm 190 providing and fixing factory made pvc door shutter made of solid foam pvc profiles of thickness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top / bottom / lock) rails of minimum cross section of 70mm x 28mm, of shape and design as per manufacturers specifications having homogenous fine cellular structure and smooth integral outer skin, inserted with g.l. c section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stiffeners as per manufacturers specifications mitered cut joints for styles and rails provided with telescopic polymeric l corners are joined together using solvent adhesive and strengthened with fully threaded stainless steel screws (of required size) through reinforcement stiffener with paneling of specified solid foam pvc board / high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam pvc moulded headings of required size using pvc solvent adhesive / cement. the finished door shutter including ss hardware, 1 no. ss sliding door bolt 200 x 10mm, 1 no. ss tower bolt 200 x 10mm and 2 nos. ss handles 125 mm, shall be fixed to frame with 3 nos. stainless steel hinges of minimum size 100x58x1.9mm and stainless steel screws of required size complete as per direction of the engineer-in-charge.(cost of above hardware is inclusive in rates) 5 mm thick solid foam pvc panel of required size with moulded/extruded beading of appropriate design shape and size as per manufacturers specifications (to secure the panel insert tight in place within the style and rails of the shutter)matching the color &shade of shutter frame - non decorative type. 191 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 192 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 193 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 194 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 195 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 196 4.0 mm thick glass panes 197 applying priming coat : 198 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 199 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 200 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 201 two or more coats on new work 202 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 203 one or more coats on old work 204 repairs to flooring 205 miscellaneous 206 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 207 in cement mortar 208 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 209 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) : 3 graded stone aggregate 20 mm nominal size). 210 centering and shuttering including strutting, propping etc. and removal of form for all heights : 211 edges of slabs and breaks in floors and walls 212 under 20 cm wide 213 centering and shuttering including strutting, propping etc. and removal of form for all heights : 214 suspended floors, roofs, landings, balconies and access platform. 215 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 216 thermo-mechanically treated bars of grade fe-500d or more. 217 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 218 cement mortar 1:6 (1 cement : 6 coarse sand) 219 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 220 cement mortar 1:4 (1 cement :4 coarse sand 221 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 222 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 223 electrical work of school building 224 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 225 group c 226 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 227 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 228 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 229 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 230 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 231 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 232 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 233 group c 234 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 235 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 236 2 x 1.5 sq. mm 237 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 32 mm 240 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 241 100 mm x 100 mm x 60 mm deep 242 150 mm x 75 mm x 60 mm deep 243 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 244 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 245 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 246 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 247 supplying and fixing brass batten/ angle holder including connection etc. as required. 248 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 249 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 250 6 way, double door 251 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 252 4 way (4 + 12), double door 253 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 254 single pole 255 single pole and neutral 256 triple pole 257 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 258 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 259 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 260 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/ coke and salt as required. 261 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 262 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 263 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 264 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 265 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 266 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover 3on the fan box etc. as required. 267 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 268 upto 450 mm sweep 269 supply of 15w surface mounted round led with all accessories as per standard item.. 270 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 271 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 272 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 273 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 274 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 275 450 mm sweep 1400 rpm 276 lightning conductor 277 providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, g.i. tube, having single prong at top, with 85 mm dia 6 mm thick g.i. base plate including holes etc. complete as required. 278 fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 279 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 280 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 281 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 282 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 283 providing and fixing testing joint, made of 20 mm x 3 mm thick g.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chuck nuts and spring washers etc. complete as required. 284 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. details of cost for one set 285 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 286 bill of quantity for boys dinning hall 287 repairs to roof 288 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 289 asbestos cement sheet 290 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 291 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 292 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 293 repair to plaster and plinth protection 294 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 295 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 296 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 297 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 298 with cement mortar 1:4 (1cement: 4 coarse sand) 299 12mm cement plaster of mix : 300 1:6 (1 cement : 6 course sand) 301 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 302 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 303 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 304 old work (one or more coats) 305 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 306 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 307 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 308 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 309 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 310 repairs to door / windows 311 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 312 of area 3 sq. metres and below 313 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 314 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 315 renewal of old putty of glass panes (length) 316 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 317 35 mm thick including isi marked stainless steel butt hinges with necessary screws 318 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 319 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 320 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 321 300 mm weighing not less than 200gms. 322 250 mm weighing not less than 150gms. 323 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 324 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 325 300 x 10mm 326 150 x 10mm 327 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 328 with 12 mm mild steel u beading 329 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 330 125 mm 331 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 332 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 333 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 334 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 335 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 336 4.0 mm thick glass panes 337 applying priming coat : 338 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 339 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 340 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 341 two or more coats on new work 342 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 343 one or more coats on old work 344 flooring 345 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 346 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 347 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 348 25 mm thick 349 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 350 miscellaneous 351 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 352 in cement mortar 353 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 354 cement mortar 1:6 (1 cement : 6 coarse sand) 355 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 356 75 to 80 mm dia pipe 357 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 358 110 mm diameter 359 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 360 a) coupler 361 110 mm 362 b) bend 87.5° 363 110 mm bend 364 kitchen & dinning 365 structural repair & retrofitting 366 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 367 50mm average thickness 368 25 mm average thickness 369 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 370 bars upto 12 mm diameter 371 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 372 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 373 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 374 25mm thick in grade m 25 with cement content not less than 330 kg per cum 375 50mm thick in grade m 25 with cement content not less than 330 kg per cum 376 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 377 repairs to roof 378 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 379 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 380 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 381 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 382 asbestos cement sheet 383 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 384 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 385 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 386 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 387 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 388 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.electric resistance or induction butt welded tubes. 389 repair to toilets + plumbing works 390 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 391 for thickness of tiles 10 mm to 25 mm 392 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 393 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 394 plumbing work 395 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 396 75 to 80 mm dia pipe 397 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 398 15 mm to 40 mm nominal bore 399 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 400 up to 150 mm diameter 401 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 402 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 403 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 404 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 405 rectangular manhole 90x80 cm and 45 cm deep 406 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 407 110 mm diameter 408 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 409 a) coupler 410 110 mm 411 b) bend 87.5° 412 110 mm bend 413 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 414 75 mm diameter pipes 415 100 mm diameter pipes 416 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 417 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 418 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 419 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 420 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 421 a) 32mm dia (for wash basin) 422 b) 40mm dia (for sink and urinal) 423 providing & fixing c.p. brass waste coupling for pvc waste pipe. 424 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 425 110 mm dia (wall thickness - 3.2 to 3.8 mm) 426 75 mm dia (wall thickness - 3.2 to 3.8 mm) 427 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 428 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 429 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 430 p-trap type floor trap 110 x 75 mm 431 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 432 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 433 providing and fixing 100 mm sand cast iron grating for gully trap. 434 providing & fixing soil, waste and vent pipes. 435 a) 100mm dia centrifugally cast iron s & s pipe. 436 b)75mm dia centrifugally cast iron s & s pipe. 437 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 438 a) for 100mm dia pipe. 439 b) for 75mm dia pipe. 440 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 441 a) 100mm 442 sand cast iron s&s as per is - 3989 443 b) 75mm 444 sand cast iron s&s as per is- 3989 445 providing and fixing plaincast iron s & s sanitary bend. 446 a) 100mm 447 sand cast iron s&s as per is - 1729 448 b) 75mm 449 sand cast iron s&s as per is - 3989 450 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 451 a) 100x100x100mm 452 b) 75x75x75mm 453 providing and fixingcast iron terminal guard. 454 a) 100mm 455 b) 75mm 456 providing & fixingcast iron coller. 457 a)100 mm 458 sand cast iron s&s as per is - 3989 459 b)75mm dia. 460 sand cast iron s&s as per is - 3989 461 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 462 a) 100mm 463 b) 75mm 464 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 465 a) 100mm inlet & 75mm outlet. 466 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 467 providing and fixing ptmt urinal cock of approved quality and colour. 468 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 469 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 470 15 mm nominal outer dia pipes 471 20 mm nominal outer dia pipes 472 25 mm nominal outer dia pipes 473 32 mm nominal outer dia pipes 474 providing and fixing brass stop cock of approved quality. 475 15 mm nominal bore 476 providing and fixing gun metal gate valve with wheel of approved quality. 477 a) 25mm dia nominal bore 478 b) 32mm dia nominal bore 479 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 480 a) 25mm. nominal bore 481 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 482 a) 15mm nominal bore 483 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 484 a) 15mm nominal bore 485 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 486 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 487 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 488 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 489 providing & fixing cp brass bib cock of approved quality conforming to is 8931 490 a) 15mm nominal bore 491 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 492 a) 15mm nominal bore 493 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 494 15mm nominal bore 495 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 496 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 497 25mm nominal bore, weighing not less than 62 gms 498 cutting holes up to 30x30 cm in walls including making good the same: 499 with common burnt clay f.p.s. (non modular) bricks 500 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 501 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 502 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 503 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 504 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 505 repair to plaster and plinth protection 506 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 507 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 508 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 509 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 510 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 511 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 512 with cement mortar 1:4 (1cement: 4 coarse sand) 513 12mm cement plaster of mix : 514 1:6 (1 cement : 6 course sand) 515 6mm cement plaster to ceiling of mix : 516 1:3 ( 1 cement : 3 fine sand) 517 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 518 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 519 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 520 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 521 old work (one or more coats) 522 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 523 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 524 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 525 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 526 repairs to door / windows 527 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 528 of area 3 sq. metres and below 529 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 530 of area 3 sq. metres and below 531 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 532 float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 533 renewal of old putty of glass panes (length) 534 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 535 35 mm thick including isi marked stainless steel butt hinges with necessary screws 536 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 537 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 538 300 mm weighing not less than 200gms. 539 250 mm weighing not less than 150gms. 540 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 541 100x58x1.90 mm 542 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 543 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 544 300 x 10mm 545 200 x 10mm 546 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 547 125 mm 548 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 549 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (puf) /polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 550 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 551 with 12 mm mild steel u beading 552 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 553 using flats 30x6mm for diagonal braces and central cross piece 554 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 555 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 556 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size). 557 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 558 4.0 mm thick glass panes 559 applying priming coat : 560 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 561 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 562 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 563 two or more coats on new work 564 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 565 one or more coats on old work 566 miscellaneous 567 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 568 in cement mortar 569 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 570 cement mortar 1:6 (1 cement : 6 coarse sand) 571 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement : 572 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) : 3 graded stone aggregate 20 mm nominal size). 573 centering and shuttering including strutting, propping etc. and removal of form for all heights : 574 edges of slabs and breaks in floors and walls 575 under 20 cm wide 576 centering and shuttering including strutting, propping etc. and removal of form for all heights : 577 suspended floors, roofs, landings, balconies and access platform. 578 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 579 thermo-mechanically treated bars of grade fe-500d or more. 580 electrical work of kitchen & dinning 581 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 582 group c 583 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 584 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 585 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 586 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 587 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 588 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 589 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 590 group c 591 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 592 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 593 2 x 1.5 sq. mm 594 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 595 25 mm 596 32 mm 597 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 598 100 mm x 100 mm x 60 mm deep 599 150 mm x 75 mm x 60 mm deep 600 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 601 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 602 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 603 supplying and fixing brass batten/ angle holder including connection etc. as required. 604 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 605 4 way (4 + 12), double door 606 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 607 single pole 608 single pole and neutral 609 triple pole 610 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 611 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 612 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 613 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/ coke and salt as required. 614 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 615 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 616 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 617 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 618 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 619 supply of 15w surface mounted round led with all accessories as per standard item.. 620 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 621 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 622 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 623 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 624 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 625 450 mm sweep 1400 rpm 626 cost of mp hall 627 structural repair & retrofitting 628 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 629 50 mm average thickness 630 25 mm average thickness 631 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 632 bars upto 12 mm diameter 633 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 634 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 635 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 636 25mm thick in grade m 25 with cement content not less than 330 kg per cum 637 50mm thick in grade m 25 with cement content not less than 330 kg per cum 638 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 639 repairs to roof 640 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 641 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 642 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 643 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 644 asbestos cement sheet 645 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 646 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 647 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 648 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 649 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 650 repair to plaster and plinth protection 651 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 652 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 653 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 654 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 655 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 656 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 657 with cement mortar 1:4 (1cement: 4 coarse sand) 658 12mm cement plaster of mix : 659 1:6 (1 cement : 6 course sand) 660 6mm cement plaster to ceiling of mix : 661 1:3 ( 1 cement : 3 fine sand) 662 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 663 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 664 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 665 old work (one or more coats) 666 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 667 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 668 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 669 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 670 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 671 repairs to door / windows 672 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 673 of area 3 sq. metres and below 674 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 675 of area 3 sq. metres and below 676 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 677 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 678 renewal of old putty of glass panes (length) 679 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 680 35 mm thick including isi marked stainless steel butt hinges with necessary screws 681 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 682 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 683 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 684 300 mm weighing not less than 200gms. 685 250 mm weighing not less than 150gms. 686 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 687 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 688 300 x 10mm 689 150 x 10mm 690 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 691 with 12 mm mild steel u beading 692 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 693 125 mm 694 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 695 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 696 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 697 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 698 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 699 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 700 4.0 mm thick glass panes 701 applying priming coat : 702 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 703 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 704 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 705 two or more coats on new work 706 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 707 one or more coats on old work 708 flooring 709 miscellaneous 710 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 711 in cement mortar 712 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 713 cement mortar 1:6 (1 cement : 6 coarse sand) 714 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 715 cement mortar 1:4 (1 cement :4 coarse sand 716 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 717 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 718 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 719 75 to 80 mm dia pipe 720 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 721 110 mm diameter 722 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 723 a) coupler 724 110 mm 725 b) bend 87.5° 726 110 mm bend 727 electrical work 728 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 729 group c 730 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 731 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 732 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 733 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 734 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 735 2 x 1.5 sq. mm 736 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 737 25 mm 738 32 mm 739 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 740 100 mm x 100 mm x 60 mm deep 741 150 mm x 75 mm x 60 mm deep 742 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 743 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 744 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 745 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 746 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 747 6 way, double door 748 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 749 4 way (4 + 12), double door 750 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 751 single pole 752 single pole and neutral 753 triple pole 754 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 755 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 756 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 757 upto 450 mm sweep 758 supply of 15w surface mounted round led with all accessories as per standard item.. 759 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 760 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 761 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 762 supply of 30w led recess mounted fixturemake-philips cat no.rc380b led30s-6500 l60w60 psd od s1 or equivalent. 763 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 764 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 765 450 mm sweep 1400 rpm 766 boysdormitory (g) for 72 students 767 structural repair & retrofitting 768 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 769 50 mm average thickness 770 25 mm average thickness 771 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 772 bars upto 12 mm diameter 773 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 774 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 775 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 776 25mm thick in grade m 25 with cement content not less than 330 kg per cum 777 50mm thick in grade m 25 with cement content not less than 330 kg per cum 778 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 779 expansion joint treatment 780 providing and fixing of expansion joint system related with floor location as per drawings and direction of engineer-in-charge. the joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per astm b221-02. the system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. system shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. the cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. the self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. provision of moisture barrier membrane in the joint system to have watertight joint is mandatory requirement all as per the manufactures design and as approved by engineer -in- charge. (material shall confirm to astm 6063). 781 floor joint of 100 mm gap 782 providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of engineer-in- charge. the joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per astm b221- 02. the material shall be such that it provides an expansion joints systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office buildings & complexes with no slipping down tendency amongst the components of the joint system. the joint system shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (material shall confirm to astm 6063). 783 wall joint of 100 mm gap 784 providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of engineer-in-charge. the joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per astm b221-02. the system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. system shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. the cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. the self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. the joint system shall resists damage or deterioration from the impact of falling ice, exposure to uv, airborne contaminants and occasional foot traffic from maintenance personnel. provision of moisture barrier membrane in the joint system to have water tight joint is mandatory requirement. (material shall confirm to astm 6063.) 785 roof joint of 100 mm gap 786 repairs to roof 787 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 788 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 789 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 790 repair to toilets 791 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 792 nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 793 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 794 for thickness of tiles 10 mm to 25 mm 795 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 796 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 797 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 798 providing and filling of cinder in sunken portions. 799 repair to plaster and plinth protection 800 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 801 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 802 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 803 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 804 with cement mortar 1:4 (1cement: 4 coarse sand) 805 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 806 15mm cement plaster on rough side of single or half brick wall of mix 807 1:6 (1 cement : 6 course sand) 808 6mm cement plaster to ceiling of mix : 809 1:3 ( 1 cement : 3 fine sand) 810 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 811 two coats 812 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 813 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 814 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 815 washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of engineer-in-charge (payment for providing grooves shall be made separately). 816 forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the engineer-in-charge : 817 15 mm wide and 15 mm deep groove 818 repairs to door / windows 819 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 820 of area 3 sq. metres and below 821 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 822 of area 3 sq. metres and below 823 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 824 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 825 renewal of old putty of glass panes (length) 826 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 827 35 mm thick including isi marked stainless steel butt hinges with necessary screws 828 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 829 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete .fixed to steel windows by welding 830 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 831 300 mm weighing not less than 200gms. 832 250 mm weighing not less than 150gms. 833 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 834 100x58x1.90 mm 835 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 836 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 837 300 x 10mm 838 150 x 10mm 839 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 840 125 mm 841 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 842 twin rubber stopper 843 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 844 providing and fixing to existing door frames. 845 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 846 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4mm in both directions for doors, windows and clerestory windows with necessary screws : 847 35 mm thick shutters.with isi marked stainless steel butt hinges of required size. kiln seasoned and chemically treated hollock wood. 848 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 849 with 12 mm mild steel u beading 850 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 851 using flats 30x6mm for diagonal braces and central cross piece 852 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 853 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 854 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 855 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 856 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 857 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 858 steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 859 in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 860 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 861 4.0 mm thick glass panes 862 applying priming coat : 863 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 864 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 865 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 866 two or more coats on new work 867 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 868 one or more coats on old work 869 repairs to flooring 870 miscellaneous 871 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 872 in cement mortar 873 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 874 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 875 cement mortar 1:6 (1 cement : 6 coarse sand) 876 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 877 cement mortar 1:4 (1 cement :4 coarse sand 878 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 879 plumbing work of boysdormitory (g) for 72 students 880 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 881 75 to 80 mm dia pipe 882 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 883 15 mm to 40 mm nominal bore 884 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 885 up to 150 mm diameter 886 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 887 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 888 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 889 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 890 up to 150 mm diameter 891 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 892 rectangular manhole 90x80 cm and 45 cm deep 893 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 894 110 mm diameter 895 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 896 a) coupler 897 110 mm 898 b) bend 87.5° 899 110 mm bend 900 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 901 75 mm diameter pipes 902 100 mm diameter pipes 903 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 904 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 905 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 906 w.c. pan with isi marked white solid plastic seat and lid 907 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 908 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 909 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 910 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 911 a) 32mm dia (for wash basin) 912 b) 40mm dia (for sink and urinal) 913 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 914 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 915 providing & fixing c.p. brass waste coupling for pvc waste pipe. 916 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 917 110 mm dia (wall thickness - 3.2 to 3.8 mm) 918 75 mm dia (wall thickness - 3.2 to 3.8 mm) 919 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 920 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 921 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 922 p-trap type floor trap 110 x 75 mm 923 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 924 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 925 providing and fixing 100 mm sand cast iron grating for gully trap. 926 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 927 providing and fixing toilet paper holder : 928 vitreous china 929 providing & fixing soil, waste and vent pipes. 930 a) 100mm dia centrifugally cast iron s & s pipe. 931 b)75mm dia centrifugally cast iron s & s pipe. 932 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 933 a) for 100mm dia pipe. 934 b) for 75mm dia pipe. 935 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 936 a) 100mm 937 sand cast iron s&s as per is - 3989 938 b) 75mm 939 sand cast iron s&s as per is- 3989 940 providing and fixing plaincast iron s & s sanitary bend. 941 a) 100mm 942 sand cast iron s&s as per is - 1729 943 b) 75mm 944 sand cast iron s&s as per is - 3989 945 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 946 a) 100x100x100mm 947 b) 75x75x75mm 948 providing and fixingcast iron terminal guard. 949 a) 100mm 950 b) 75mm 951 providing & fixingcast iron coller. 952 a)100 mm 953 sand cast iron s&s as per is - 3989 954 b)75mm dia. 955 sand cast iron s&s as per is - 3989 956 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 957 a) 100mm 958 b) 75mm 959 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 960 a) 100mm inlet & 75mm outlet. 961 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 962 providing and fixing ptmt urinal cock of approved quality and colour. 963 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 964 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 965 15 mm nominal outer dia pipes 966 20 mm nominal outer dia pipes 967 25 mm nominal outer dia pipes 968 32 mm nominal outer dia pipes 969 providing and fixing brass stop cock of approved quality. 970 15 mm nominal bore 971 providing and fixing gun metal gate valve with wheel of approved quality. 972 a) 25mm dia nominal bore 973 b) 32mm dia nominal bore 974 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 975 a) 25mm. nominal bore 976 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 977 a) 15mm nominal bore 978 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 979 a) 15mm nominal bore 980 providing & fixing cp brass bib cock of approved quality conforming to is 8931 981 a) 15mm nominal bore 982 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 983 a) 15mm nominal bore 984 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 985 15mm nominal bore 986 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 987 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 988 25mm nominal bore, weighing not less than 62 gms 989 cutting holes up to 30x30 cm in walls including making good the same: 990 with common burnt clay f.p.s. (non modular) bricks 991 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 992 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 993 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 994 electrical work of boysdormitory (g) for 72 students 995 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 996 group b 997 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 998 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 999 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1000 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1001 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1002 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1003 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1004 group b 1005 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1006 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1007 2 x 1.5 sq. mm 1008 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1009 25 mm 1010 32 mm 1011 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1012 100 mm x 100 mm x 60 mm deep 1013 150 mm x 75 mm x 60 mm deep 1014 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1015 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1016 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1017 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1018 supplying and fixing brass batten/ angle holder including connection etc. as required. 1019 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1020 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1021 6 way, double door 1022 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1023 4 way (4 + 12), double door 1024 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1025 single pole 1026 single pole and neutral 1027 triple pole 1028 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1029 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1030 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1031 supply of 15w surface mounted round led with all accessories as per standard item.. 1032 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1033 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1034 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1035 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 1036 girls dormitories(cpwd type) 1 block 1037 structural repair & retrofitting 1038 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1039 50mm average thickness 1040 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1041 bars upto 12 mm diameter 1042 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1043 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1044 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1045 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1046 repairs to roof 1047 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1048 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1049 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1050 repair to toilets 1051 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1052 for thickness of tiles 10 mm to 25 mm 1053 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1054 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1055 repair to plaster and plinth protection 1056 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. 1057 two or more coats on new work 1058 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1059 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1060 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1061 15mm cement plaster on rough side of single or half brick wall of mix 1062 1:6 (1 cement : 6 course sand) 1063 6mm cement plaster to ceiling of mix : 1064 1:3 ( 1 cement : 3 fine sand) 1065 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1066 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1067 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1068 old work (one or more coats) 1069 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1070 washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of engineer-in-charge (payment for providing grooves shall be made separately). 1071 forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the engineer-in-charge : 1072 15 mm wide and 15 mm deep groove 1073 repairs to door / windows 1074 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1075 of area 3 sq. metres and below 1076 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1077 of area 3 sq. metres and below 1078 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 1079 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1080 renewal of old putty of glass panes (length) 1081 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete .fixed to steel windows by welding 1082 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1083 250 mm weighing not less than 150gms. 1084 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1085 100x58x1.90 mm 1086 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1087 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1088 300 x 10mm 1089 150 x 10mm 1090 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1091 125 mm 1092 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1093 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1094 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1095 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including isi marked stainless steel butt hinges with necessary screws 1096 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1.5 mm thick. 1097 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 1098 with 12 mm mild steel u beading 1099 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1100 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1101 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 1102 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1103 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1104 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1105 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1106 4.0 mm thick glass panes 1107 applying priming coat : 1108 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1109 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1110 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1111 two or more coats on new work 1112 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1113 one or more coats on old work 1114 miscellaneous 1115 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 1116 in cement mortar 1117 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1118 cement mortar 1:6 (1 cement : 6 coarse sand) 1119 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1120 cement mortar 1:4 (1 cement :4 coarse sand 1121 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1122 plumbing work of girlsdormitory (g) for 48 students 1123 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1124 75 to 80 mm dia pipe 1125 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1126 15 mm to 40 mm nominal bore 1127 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1128 up to 150 mm diameter 1129 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1130 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1131 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1132 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1133 up to 150 mm diameter 1134 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1135 rectangular manhole 90x80 cm and 45 cm deep 1136 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1137 110 mm diameter 1138 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1139 a) coupler 1140 110 mm 1141 b) bend 87.5° 1142 110 mm bend 1143 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1144 75 mm diameter pipes 1145 100 mm diameter pipes 1146 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1147 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1148 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1149 w.c. pan with isi marked white solid plastic seat and lid 1150 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1151 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1152 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1153 a) 32mm dia (for wash basin) 1154 b) 40mm dia (for sink and urinal) 1155 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 1156 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1157 providing & fixing c.p. brass waste coupling for pvc waste pipe. 1158 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1159 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1160 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1161 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1162 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1163 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1164 p-trap type floor trap 110 x 75 mm 1165 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1166 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1167 providing and fixing 100 mm sand cast iron grating for gully trap. 1168 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1169 providing and fixing toilet paper holder : 1170 vitreous china 1171 providing & fixing soil, waste and vent pipes. 1172 a) 100mm dia centrifugally cast iron s & s pipe. 1173 b)75mm dia centrifugally cast iron s & s pipe. 1174 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1175 a) for 100mm dia pipe. 1176 b) for 75mm dia pipe. 1177 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1178 a) 100mm 1179 sand cast iron s&s as per is - 3989 1180 b) 75mm 1181 sand cast iron s&s as per is- 3989 1182 providing and fixing plaincast iron s & s sanitary bend. 1183 a) 100mm 1184 sand cast iron s&s as per is - 1729 1185 b) 75mm 1186 sand cast iron s&s as per is - 3989 1187 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1188 a) 100x100x100mm 1189 b) 75x75x75mm 1190 providing and fixingcast iron terminal guard. 1191 a) 100mm 1192 b) 75mm 1193 providing & fixingcast iron coller. 1194 a)100 mm 1195 sand cast iron s&s as per is - 3989 1196 b)75mm dia. 1197 sand cast iron s&s as per is - 3989 1198 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1199 a) 100mm 1200 b) 75mm 1201 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1202 a) 100mm inlet & 75mm outlet. 1203 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1204 15 mm nominal outer dia pipes 1205 20 mm nominal outer dia pipes 1206 25 mm nominal outer dia pipes 1207 32 mm nominal outer dia pipes 1208 providing and fixing brass stop cock of approved quality. 1209 15 mm nominal bore 1210 providing and fixing gun metal gate valve with wheel of approved quality. 1211 a) 25mm dia nominal bore 1212 b) 32mm dia nominal bore 1213 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1214 a) 25mm. nominal bore 1215 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1216 a) 15mm nominal bore 1217 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1218 a) 15mm nominal bore 1219 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1220 a) 15mm nominal bore 1221 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1222 a) 15mm nominal bore 1223 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1224 15mm nominal bore 1225 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1226 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1227 25mm nominal bore, weighing not less than 62 gms 1228 cutting holes up to 30x30 cm in walls including making good the same: 1229 with common burnt clay f.p.s. (non modular) bricks 1230 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1231 electrical work of girlsdormitory (g) for 48 students 1232 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1233 group b 1234 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1235 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1236 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1237 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1238 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1239 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1240 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1241 group b 1242 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1243 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1244 2 x 1.5 sq. mm 1245 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1246 25 mm 1247 32 mm 1248 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1249 100 mm x 100 mm x 60 mm deep 1250 150 mm x 75 mm x 60 mm deep 1251 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1252 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1253 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1254 supplying and fixing brass batten/ angle holder including connection etc. as required. 1255 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1256 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1257 4 way (4 + 12), double door 1258 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1259 single pole 1260 single pole and neutral 1261 triple pole 1262 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1263 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1264 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1265 supply of 15w surface mounted round led with all accessories as per standard item.. 1266 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1267 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1268 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1269 staff qtrs type-iii . 1270 structural repair & retrofitting 1271 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1272 50 mm average thickness 1273 25 mm average thickness 1274 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1275 bars upto 12 mm diameter 1276 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1277 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1278 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1279 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1280 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1281 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 1282 repairs to roof 1283 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1284 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1285 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1286 repair to toilets 1287 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1288 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1289 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1290 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1291 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1292 providing and filling of cinder in sunken portions. 1293 repair to plaster and plinth protection 1294 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1295 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1296 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1297 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1298 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1299 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1300 with cement mortar 1:4 (1cement: 4 coarse sand) 1301 12mm cement plaster of mix : 1302 1:6 (1 cement : 6 course sand) 1303 6mm cement plaster to ceiling of mix : 1304 1:3 ( 1 cement : 3 fine sand) 1305 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1306 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1307 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1308 old work (one or more coats) 1309 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1310 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1311 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1312 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1313 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1314 repairs to door / windows 1315 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1316 of area 3 sq. metres and below 1317 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1318 of area 3 sq. metres and below 1319 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1320 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1321 renewal of old putty of glass panes (length) 1322 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1323 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1324 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1325 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1326 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1327 300 mm weighing not less than 200gms. 1328 250 mm weighing not less than 150gms. 1329 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1330 100x58x1.90 mm 1331 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1332 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1333 300 x 10mm 1334 150 x 10mm 1335 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 1336 providing and fixing to existing door frames. 1337 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1338 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1339 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1340 with isi marked stainless steel butt hinges of required size 1341 kiln seasoned and chemically treated hollock wood 1342 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1343 with 12 mm mild steel u beading 1344 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1345 125 mm 1346 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1347 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1348 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1349 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1350 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1351 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1352 4.0 mm thick glass panes 1353 applying priming coat : 1354 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1355 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1356 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1357 two or more coats on new work 1358 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1359 one or more coats on old work 1360 miscellaneous 1361 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1362 cement mortar 1:6 (1 cement : 6 coarse sand) 1363 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1364 cement mortar 1:4 (1 cement :4 coarse sand 1365 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1366 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1367 plumbing work of type-iii (g+1) 1368 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1369 75 to 80 mm dia pipe 1370 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1371 15 mm to 40 mm nominal bore 1372 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1373 up to 150 mm diameter 1374 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1375 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1376 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1377 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1378 up to 150 mm diameter 1379 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1380 rectangular manhole 90x80 cm and 45 cm deep 1381 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1382 110 mm diameter 1383 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1384 a) coupler 1385 110 mm 1386 b) bend 87.5° 1387 110 mm bend 1388 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1389 75 mm diameter pipes 1390 100 mm diameter pipes 1391 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1392 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1393 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1394 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1395 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1396 kitchen sink without drain board 1397 610x510 mm bowl depth 200 mm 1398 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1399 a) 32mm dia (for wash basin) 1400 b) 40mm dia (for sink and urinal) 1401 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1402 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1403 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1404 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1405 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1406 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1407 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1408 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1409 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1410 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1411 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1412 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1413 p-trap type floor trap 110 x 75 mm 1414 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1415 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1416 providing and fixing 100 mm sand cast iron grating for gully trap. 1417 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1418 providing & fixing soil, waste and vent pipes. 1419 a) 100mm dia centrifugally cast iron s & s pipe. 1420 b)75mm dia centrifugally cast iron s & s pipe. 1421 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1422 a) for 100mm dia pipe. 1423 b) for 75mm dia pipe. 1424 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1425 a) 100mm 1426 sand cast iron s&s as per is - 3989 1427 b) 75mm 1428 sand cast iron s&s as per is- 3989 1429 providing and fixing plaincast iron s & s sanitary bend. 1430 a) 100mm 1431 sand cast iron s&s as per is - 1729 1432 b) 75mm 1433 sand cast iron s&s as per is - 3989 1434 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1435 a) 100x100x100mm 1436 b) 75x75x75mm 1437 providing and fixingcast iron terminal guard. 1438 a) 100mm 1439 b) 75mm 1440 providing & fixingcast iron coller. 1441 a)100 mm 1442 sand cast iron s&s as per is - 3989 1443 b)75mm dia. 1444 sand cast iron s&s as per is - 3989 1445 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1446 a) 100mm 1447 b) 75mm 1448 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1449 a) 100mm inlet & 75mm outlet. 1450 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1451 15 mm nominal outer dia pipes 1452 20 mm nominal outer dia pipes 1453 25 mm nominal outer dia pipes 1454 32 mm nominal outer dia pipes 1455 providing and fixing brass stop cock of approved quality. 1456 15 mm nominal bore 1457 providing and fixing gun metal gate valve with wheel of approved quality. 1458 a) 25mm dia nominal bore 1459 b) 32mm dia nominal bore 1460 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1461 a) 25mm. nominal bore 1462 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1463 a) 15mm nominal bore 1464 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1465 a) 15mm nominal bore 1466 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1467 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1468 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1469 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1470 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1471 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1472 a) 15mm nominal bore 1473 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1474 a) 15mm nominal bore 1475 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1476 a) 15mm nominal bore 1477 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1478 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1479 25mm nominal bore, weighing not less than 62 gms 1480 cutting holes up to 30x30 cm in walls including making good the same: 1481 with common burnt clay f.p.s. (non modular) bricks 1482 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1483 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1484 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1485 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1486 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1487 electrical work of type-iii (g+1) 1488 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1489 group b 1490 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1491 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1492 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1493 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1494 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1495 xxxx 1496 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1497 group b 1498 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1499 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1500 2 x 1.5 sq. mm 1501 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1502 25 mm 1503 32 mm 1504 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1505 100 mm x 100 mm x 60 mm deep 1506 150 mm x 75 mm x 60 mm deep 1507 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1508 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1509 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1510 s/f light plug point modular type accessories :- 1511 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1512 s/f power plug point modular type accessories :- 1513 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1514 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1515 supplying and fixing brass batten/ angle holder including connection etc. as required. 1516 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1517 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1518 6 way, double door 1519 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1520 4 way (4 + 12), double door 1521 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1522 single pole 1523 single pole and neutral 1524 triple pole 1525 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1526 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1527 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1528 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1529 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1530 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1531 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1532 supply of 15w surface mounted round led with all accessories as per standard item.. 1533 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1534 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1535 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1536 staff qtrs type-iii . 1537 structural repair & retrofitting 1538 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1539 50 mm average thickness 1540 25 mm average thickness 1541 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1542 bars upto 12 mm diameter 1543 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1544 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1545 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1546 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1547 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1548 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 1549 repairs to roof 1550 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1551 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1552 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1553 repair to toilets 1554 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1555 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1556 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1557 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1558 repair to plaster and plinth protection 1559 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1560 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1561 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1562 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1563 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1564 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1565 with cement mortar 1:4 (1cement: 4 coarse sand) 1566 12mm cement plaster of mix : 1567 1:6 (1 cement : 6 course sand) 1568 6mm cement plaster to ceiling of mix : 1569 1:3 ( 1 cement : 3 fine sand) 1570 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1571 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1572 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1573 old work (one or more coats) 1574 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1575 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1576 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1577 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1578 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1579 repairs to door / windows 1580 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1581 of area 3 sq. metres and below 1582 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1583 of area 3 sq. metres and below 1584 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1585 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1586 renewal of old putty of glass panes (length) 1587 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1588 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1589 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1590 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1591 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1592 300 mm weighing not less than 200gms. 1593 250 mm weighing not less than 150gms. 1594 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1595 100x58x1.90 mm 1596 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1597 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1598 300 x 10mm 1599 150 x 10mm 1600 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 1601 providing and fixing to existing door frames. 1602 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1603 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1604 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1605 with isi marked stainless steel butt hinges of required size 1606 kiln seasoned and chemically treated hollock wood 1607 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1608 with 12 mm mild steel u beading 1609 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1610 125 mm 1611 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1612 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1613 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1614 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1615 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1616 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1617 4.0 mm thick glass panes 1618 applying priming coat : 1619 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1620 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1621 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1622 two or more coats on new work 1623 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1624 one or more coats on old work 1625 flooring 1626 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1627 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1628 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1629 25 mm thick 1630 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1631 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 1632 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 1633 miscellaneous 1634 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1635 cement mortar 1:6 (1 cement : 6 coarse sand) 1636 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1637 cement mortar 1:4 (1 cement :4 coarse sand 1638 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1639 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1640 plumbing work of type-iii (g) 1641 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1642 75 to 80 mm dia pipe 1643 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1644 15 mm to 40 mm nominal bore 1645 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1646 up to 150 mm diameter 1647 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1648 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1649 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1650 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1651 up to 150 mm diameter 1652 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1653 rectangular manhole 90x80 cm and 45 cm deep 1654 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1655 110 mm diameter 1656 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1657 a) coupler 1658 110 mm 1659 b) bend 87.5° 1660 110 mm bend 1661 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1662 75 mm diameter pipes 1663 100 mm diameter pipes 1664 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1665 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1666 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1667 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1668 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1669 kitchen sink without drain board 1670 610x510 mm bowl depth 200 mm 1671 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1672 a) 32mm dia (for wash basin) 1673 b) 40mm dia (for sink and urinal) 1674 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1675 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1676 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1677 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1678 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1679 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1680 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1681 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1682 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1683 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1684 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1685 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1686 p-trap type floor trap 110 x 75 mm 1687 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1688 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1689 providing and fixing 100 mm sand cast iron grating for gully trap. 1690 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1691 providing & fixing soil, waste and vent pipes. 1692 a) 100mm dia centrifugally cast iron s & s pipe. 1693 b)75mm dia centrifugally cast iron s & s pipe. 1694 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1695 a) for 100mm dia pipe. 1696 b) for 75mm dia pipe. 1697 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1698 a) 100mm 1699 sand cast iron s&s as per is - 3989 1700 b) 75mm 1701 sand cast iron s&s as per is- 3989 1702 providing and fixing plaincast iron s & s sanitary bend. 1703 a) 100mm 1704 sand cast iron s&s as per is - 1729 1705 b) 75mm 1706 sand cast iron s&s as per is - 3989 1707 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1708 a) 100x100x100mm 1709 b) 75x75x75mm 1710 providing and fixingcast iron terminal guard. 1711 a) 100mm 1712 b) 75mm 1713 providing & fixingcast iron coller. 1714 a)100 mm 1715 sand cast iron s&s as per is - 3989 1716 b)75mm dia. 1717 sand cast iron s&s as per is - 3989 1718 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1719 a) 100mm 1720 b) 75mm 1721 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1722 a) 100mm inlet & 75mm outlet. 1723 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1724 15 mm nominal outer dia pipes 1725 20 mm nominal outer dia pipes 1726 25 mm nominal outer dia pipes 1727 32 mm nominal outer dia pipes 1728 providing and fixing brass stop cock of approved quality. 1729 15 mm nominal bore 1730 providing and fixing gun metal gate valve with wheel of approved quality. 1731 a) 25mm dia nominal bore 1732 b) 32mm dia nominal bore 1733 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1734 a) 25mm. nominal bore 1735 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1736 a) 15mm nominal bore 1737 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1738 a) 15mm nominal bore 1739 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1740 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1741 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1742 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1743 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1744 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1745 a) 15mm nominal bore 1746 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1747 a) 15mm nominal bore 1748 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1749 a) 15mm nominal bore 1750 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1751 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1752 25mm nominal bore, weighing not less than 62 gms 1753 cutting holes up to 30x30 cm in walls including making good the same: 1754 with common burnt clay f.p.s. (non modular) bricks 1755 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1756 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1757 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1758 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1759 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1760 electrical work of type-iii (g) 1761 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1762 group b 1763 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1764 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1765 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1766 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1767 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1768 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1769 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1770 group b 1771 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1772 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1773 2 x 1.5 sq. mm 1774 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1775 25 mm 1776 32 mm 1777 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1778 100 mm x 100 mm x 60 mm deep 1779 150 mm x 75 mm x 60 mm deep 1780 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1781 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1782 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1783 s/f light plug point modular type accessories :- 1784 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1785 s/f power plug point modular type accessories :- 1786 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1787 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1788 supplying and fixing brass batten/ angle holder including connection etc. as required. 1789 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1790 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1791 6 way, double door 1792 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1793 4 way (4 + 12), double door 1794 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1795 single pole 1796 single pole and neutral 1797 triple pole 1798 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1799 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1800 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1801 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1802 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1803 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1804 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1805 supply of 15w surface mounted round led with all accessories as per standard item.. 1806 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1807 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1808 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1809 type-ii staff qtrs. 1810 structural repair & retrofitting 1811 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1812 25 mm average thickness 1813 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1814 bars upto 12 mm diameter 1815 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1816 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1817 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1818 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1819 repairs to roof 1820 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1821 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1822 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1823 repair to toilets 1824 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1825 for thickness of tiles 10 mm to 25 mm 1826 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1827 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1828 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1829 providing and filling of cinder in sunken portions. 1830 repair to plaster and plinth protection 1831 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1832 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1833 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1834 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1835 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1836 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1837 with cement mortar 1:4 (1cement: 4 coarse sand) 1838 15mm cement plaster of mix : 1839 1:6 (1 cement : 6 course sand) 1840 pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1841 raised and cut pointing 1842 6mm cement plaster to ceiling of mix : 1843 1:3 ( 1 cement : 3 fine sand) 1844 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1845 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1846 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1847 old work (one or more coats) 1848 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1849 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1850 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1851 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1852 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1853 repairs to door / windows 1854 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1855 of area 3 sq. metres and below 1856 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1857 of area 3 sq. metres and below 1858 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1859 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1860 renewal of old putty of glass panes (length) 1861 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1862 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1863 250 mm weighing not less than 150gms. 1864 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1865 100x58x1.90 mm 1866 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1867 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1868 300 x 10mm 1869 150 x 10mm 1870 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1871 125 mm 1872 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1873 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including isi marked stainless steel butt hinges with necessary screws 1874 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1.5 mm thick. 1875 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1876 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1877 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1878 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1879 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1880 4.0 mm thick glass panes 1881 applying priming coat : 1882 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1883 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1884 two or more coats on new work 1885 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1886 one or more coats on old work 1887 miscellaneous 1888 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1889 cement mortar 1:6 (1 cement : 6 coarse sand) 1890 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1891 cement mortar 1:4 (1 cement :4 coarse sand 1892 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1893 plumbing work 1894 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1895 75 to 80 mm dia pipe 1896 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1897 15 mm to 40 mm nominal bore 1898 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1899 up to 150 mm diameter 1900 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1901 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1902 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1903 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1904 up to 150 mm diameter 1905 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1906 rectangular manhole 90x80 cm and 45 cm deep 1907 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1908 110 mm diameter 1909 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1910 a) coupler 1911 110 mm 1912 b) bend 87.5° 1913 110 mm bend 1914 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1915 75 mm diameter pipes 1916 100 mm diameter pipes 1917 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1918 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1919 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1920 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1921 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1922 kitchen sink without drain board 1923 610x510 mm bowl depth 200 mm 1924 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1925 a) 32mm dia (for wash basin) 1926 b) 40mm dia (for sink and urinal) 1927 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1928 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1929 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1930 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1931 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1932 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1933 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1934 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1935 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1936 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1937 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1938 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1939 p-trap type floor trap 110 x 75 mm 1940 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1941 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1942 providing and fixing 100 mm sand cast iron grating for gully trap. 1943 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1944 providing & fixing soil, waste and vent pipes. 1945 a) 100mm dia centrifugally cast iron s & s pipe. 1946 b)75mm dia centrifugally cast iron s & s pipe. 1947 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1948 a) for 100mm dia pipe. 1949 b) for 75mm dia pipe. 1950 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1951 a) 100mm 1952 sand cast iron s&s as per is - 3989 1953 b) 75mm 1954 sand cast iron s&s as per is- 3989 1955 providing and fixing plaincast iron s & s sanitary bend. 1956 a) 100mm 1957 sand cast iron s&s as per is - 1729 1958 b) 75mm 1959 sand cast iron s&s as per is - 3989 1960 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1961 a) 100x100x100mm 1962 b) 75x75x75mm 1963 providing and fixingcast iron terminal guard. 1964 a) 100mm 1965 b) 75mm 1966 providing & fixingcast iron coller. 1967 a)100 mm 1968 sand cast iron s&s as per is - 3989 1969 b)75mm dia. 1970 sand cast iron s&s as per is - 3989 1971 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1972 a) 100mm 1973 b) 75mm 1974 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1975 a) 100mm inlet & 75mm outlet. 1976 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1977 15 mm nominal outer dia pipes 1978 20 mm nominal outer dia pipes 1979 25 mm nominal outer dia pipes 1980 32 mm nominal outer dia pipes 1981 providing and fixing brass stop cock of approved quality. 1982 15 mm nominal bore 1983 providing and fixing gun metal gate valve with wheel of approved quality. 1984 a) 25mm dia nominal bore 1985 b) 32mm dia nominal bore 1986 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1987 a) 25mm. nominal bore 1988 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1989 a) 15mm nominal bore 1990 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1991 a) 15mm nominal bore 1992 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1993 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1994 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1995 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1996 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1997 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1998 a) 15mm nominal bore 1999 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2000 a) 15mm nominal bore 2001 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2002 a) 15mm nominal bore 2003 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2004 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2005 25mm nominal bore, weighing not less than 62 gms 2006 cutting holes up to 30x30 cm in walls including making good the same: 2007 with common burnt clay f.p.s. (non modular) bricks 2008 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2009 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2010 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2011 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2012 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2013 electrical work 2014 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2015 group b 2016 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2017 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2018 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2019 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2020 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2021 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2022 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2023 group b 2024 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2025 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2026 2 x 1.5 sq. mm 2027 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2028 25 mm 2029 32 mm 2030 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2031 100 mm x 100 mm x 60 mm deep 2032 150 mm x 75 mm x 60 mm deep 2033 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2034 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2035 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2036 s/f light plug point modular type accessories :- 2037 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 2038 s/f power plug point modular type accessories :- 2039 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 2040 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2041 supplying and fixing brass batten/ angle holder including connection etc. as required. 2042 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2043 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2044 6 way, double door 2045 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2046 4 way (4 + 12), double door 2047 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2048 single pole 2049 single pole and neutral 2050 triple pole 2051 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2052 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2053 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2054 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2055 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2056 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2057 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2058 supply of 15w surface mounted round led with all accessories as per standard item.. 2059 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2060 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2061 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2062 staff qtrs type-i . 2063 structural repair & retrofitting 2064 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 2065 50 mm average thickness 2066 25 mm average thickness 2067 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 2068 bars upto 12 mm diameter 2069 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 2070 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 2071 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 2072 25mm thick in grade m 25 with cement content not less than 330 kg per cum 2073 50mm thick in grade m 25 with cement content not less than 330 kg per cum 2074 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 2075 repairs to roof 2076 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2077 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2078 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2079 repair to toilets 2080 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2081 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2082 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 2083 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2084 repair to plaster and plinth protection 2085 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2086 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2087 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2088 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2089 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2090 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2091 with cement mortar 1:4 (1cement: 4 coarse sand) 2092 12mm cement plaster of mix : 2093 1:6 (1 cement : 6 course sand) 2094 6mm cement plaster to ceiling of mix : 2095 1:3 ( 1 cement : 3 fine sand) 2096 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2097 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2098 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2099 old work (one or more coats) 2100 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2101 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2102 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2103 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2104 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2105 repairs to door / windows 2106 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2107 of area 3 sq. metres and below 2108 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2109 of area 3 sq. metres and below 2110 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2111 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2112 renewal of old putty of glass panes (length) 2113 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2114 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2115 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2116 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 2117 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2118 300 mm weighing not less than 200gms. 2119 250 mm weighing not less than 150gms. 2120 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 2121 100x58x1.90 mm 2122 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2123 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2124 300 x 10mm 2125 150 x 10mm 2126 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 2127 providing and fixing to existing door frames. 2128 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 2129 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2130 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2131 with isi marked stainless steel butt hinges of required size 2132 kiln seasoned and chemically treated hollock wood 2133 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2134 with 12 mm mild steel u beading 2135 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2136 125 mm 2137 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2138 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2139 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2140 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2141 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2142 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2143 4.0 mm thick glass panes 2144 applying priming coat : 2145 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 2146 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2147 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2148 two or more coats on new work 2149 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2150 one or more coats on old work 2151 flooring 2152 miscellaneous 2153 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2154 cement mortar 1:6 (1 cement : 6 coarse sand) 2155 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2156 cement mortar 1:4 (1 cement :4 coarse sand 2157 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2158 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2159 plumbing work of type-i (g) 2160 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2161 75 to 80 mm dia pipe 2162 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2163 15 mm to 40 mm nominal bore 2164 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2165 up to 150 mm diameter 2166 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2167 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2168 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2169 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2170 up to 150 mm diameter 2171 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2172 rectangular manhole 90x80 cm and 45 cm deep 2173 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2174 110 mm diameter 2175 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2176 a) coupler 2177 110 mm 2178 b) bend 87.5° 2179 110 mm bend 2180 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 2181 75 mm diameter pipes 2182 100 mm diameter pipes 2183 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2184 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2185 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2186 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2187 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2188 kitchen sink without drain board 2189 610x510 mm bowl depth 200 mm 2190 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2191 a) 32mm dia (for wash basin) 2192 b) 40mm dia (for sink and urinal) 2193 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2194 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2195 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2196 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2197 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 2198 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2199 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2200 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2201 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2202 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2203 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2204 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2205 p-trap type floor trap 110 x 75 mm 2206 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2207 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2208 providing and fixing 100 mm sand cast iron grating for gully trap. 2209 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2210 providing & fixing soil, waste and vent pipes. 2211 a) 100mm dia centrifugally cast iron s & s pipe. 2212 b)75mm dia centrifugally cast iron s & s pipe. 2213 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 2214 a) for 100mm dia pipe. 2215 b) for 75mm dia pipe. 2216 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 2217 a) 100mm 2218 sand cast iron s&s as per is - 3989 2219 b) 75mm 2220 sand cast iron s&s as per is- 3989 2221 providing and fixing plaincast iron s & s sanitary bend. 2222 a) 100mm 2223 sand cast iron s&s as per is - 1729 2224 b) 75mm 2225 sand cast iron s&s as per is - 3989 2226 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 2227 a) 100x100x100mm 2228 b) 75x75x75mm 2229 providing and fixingcast iron terminal guard. 2230 a) 100mm 2231 b) 75mm 2232 providing & fixingcast iron coller. 2233 a)100 mm 2234 sand cast iron s&s as per is - 3989 2235 b)75mm dia. 2236 sand cast iron s&s as per is - 3989 2237 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 2238 a) 100mm 2239 b) 75mm 2240 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 2241 a) 100mm inlet & 75mm outlet. 2242 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2243 15 mm nominal outer dia pipes 2244 20 mm nominal outer dia pipes 2245 25 mm nominal outer dia pipes 2246 32 mm nominal outer dia pipes 2247 providing and fixing brass stop cock of approved quality. 2248 15 mm nominal bore 2249 providing and fixing gun metal gate valve with wheel of approved quality. 2250 a) 25mm dia nominal bore 2251 b) 32mm dia nominal bore 2252 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2253 a) 25mm. nominal bore 2254 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2255 a) 15mm nominal bore 2256 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2257 a) 15mm nominal bore 2258 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2259 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2260 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2261 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2262 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2263 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2264 a) 15mm nominal bore 2265 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2266 a) 15mm nominal bore 2267 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2268 a) 15mm nominal bore 2269 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2270 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2271 25mm nominal bore, weighing not less than 62 gms 2272 cutting holes up to 30x30 cm in walls including making good the same: 2273 with common burnt clay f.p.s. (non modular) bricks 2274 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2275 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2276 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2277 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2278 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2279 electrical work of type-i (g) 2280 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2281 group b 2282 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2283 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2284 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2285 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2286 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2287 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2288 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2289 group b 2290 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2291 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2292 2 x 1.5 sq. mm 2293 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2294 25 mm 2295 32 mm 2296 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2297 100 mm x 100 mm x 60 mm deep 2298 150 mm x 75 mm x 60 mm deep 2299 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2300 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2301 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2302 s/f light plug point modular type accessories :- 2303 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 2304 s/f power plug point modular type accessories :- 2305 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 2306 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2307 supplying and fixing brass batten/ angle holder including connection etc. as required. 2308 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2309 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2310 6 way, double door 2311 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2312 4 way (4 + 12), double door 2313 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2314 single pole 2315 single pole and neutral 2316 triple pole 2317 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2318 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2319 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2320 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2321 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2322 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2323 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2324 supply of 15w surface mounted round led with all accessories as per standard item.. 2325 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2326 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2327 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2328 type-i (g) 5 units 2329 repairs to roof 2330 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 2331 asbestos cement sheet 2332 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 2333 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 2334 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, 2335 shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 2336 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 2337 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m* 2338 repairs to toilets 2339 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2340 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2341 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 2342 for thickness of tiles 10 mm to 25 mm 2343 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2344 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 2345 repair to plaster & plinth protection 2346 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2347 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2348 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2349 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2350 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2351 with cement mortar 1:4 (1cement: 4 coarse sand) 2352 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2353 12mm cement plaster of mix : 2354 1:6 (1 cement : 6 course sand) 2355 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2356 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2357 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2358 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2359 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2360 old work (one or more coats) 2361 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2362 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2363 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2364 repairs to door/windows 2365 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2366 of area 3 sq. metres and below 2367 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2368 of area 3 sq. metres and below 2369 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 2370 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2371 renewal of old putty of glass panes (length) 2372 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2373 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2374 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2375 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 2376 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2377 300 mm weighing not less than 200gms. 2378 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2379 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2380 300 x 10mm 2381 150 x 10mm 2382 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2383 125 mm 2384 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 2385 twin rubber stopper 2386 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2387 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2388 with isi marked stainless steel butt hinges of required size 2389 kiln seasoned and chemically treated hollock wood 2390 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2391 with 12 mm mild steel u beading 2392 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2393 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2394 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2395 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2396 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2397 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2398 4.0 mm thick glass panes 2399 applying priming coat : 2400 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 2401 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2402 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2403 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2404 one or more coats on old work 2405 miscellaneous 2406 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2407 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 2408 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 2409 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2410 cement mortar 1:6 (1 cement : 6 coarse sand) 2411 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2412 cement mortar 1:4 (1 cement :4 coarse sand 2413 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2414 plumbing work of type-i (g) 5 units 2415 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2416 15 mm to 40 mm nominal bore 2417 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2418 up to 150 mm diameter 2419 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2420 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2421 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2422 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 2423 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2424 up to 150 mm diameter 2425 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2426 rectangular manhole 90x80 cm and 45 cm deep 2427 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2428 110 mm diameter 2429 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2430 a) coupler 2431 110 mm 2432 b) bend 87.5° 2433 110 mm bend 2434 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2435 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2436 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2437 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2438 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2439 kitchen sink without drain board 2440 610x510 mm bowl depth 200 mm 2441 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2442 a) 32mm dia (for wash basin) 2443 b) 40mm dia (for sink and urinal) 2444 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2445 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2446 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2447 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2448 providing & fixing c.p. brass waste coupling for pvc waste pipe. 2449 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2450 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2451 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2452 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2453 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2454 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2455 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2456 p-trap type floor trap 110 x 75 mm 2457 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2458 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2459 providing and fixing 100 mm sand cast iron grating for gully trap. 2460 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2461 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2462 15 mm nominal outer dia pipes 2463 20 mm nominal outer dia pipes 2464 25 mm nominal outer dia pipes 2465 32 mm nominal outer dia pipes 2466 providing and fixing brass stop cock of approved quality. 2467 15 mm nominal bore 2468 providing and fixing gun metal gate valve with wheel of approved quality. 2469 a) 25mm dia nominal bore 2470 b) 32mm dia nominal bore 2471 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2472 a) 25mm. nominal bore 2473 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2474 a) 15mm nominal bore 2475 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2476 a) 15mm nominal bore 2477 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2478 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2479 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2480 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2481 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2482 a) 15mm nominal bore 2483 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2484 a) 15mm nominal bore 2485 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2486 a) 15mm nominal bore 2487 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2488 cutting holes up to 30x30 cm in walls including making good the same: 2489 with common burnt clay f.p.s. (non modular) bricks 2490 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2491 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2492 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2493 electrical work of type-i (g) 5 units 2494 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2495 group b 2496 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2497 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2498 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2499 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2500 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2501 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2502 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2503 group b 2504 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2505 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2506 2 x 1.5 sq. mm 2507 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2508 25 mm 2509 32 mm 2510 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2511 100 mm x 100 mm x 60 mm deep 2512 150 mm x 75 mm x 60 mm deep 2513 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2514 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2515 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2516 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2517 supplying and fixing brass batten/ angle holder including connection etc. as required. 2518 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2519 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2520 6 way, double door 2521 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2522 4 way (4 + 12), double door 2523 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2524 single pole 2525 single pole and neutral 2526 triple pole 2527 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2528 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2529 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2530 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2531 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2532 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2533 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2534 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover 3on the fan box etc. as required. 2535 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2536 upto 450 mm sweep 2537 supply of 15w surface mounted round led with all accessories as per standard item.. 2538 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2539 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2540 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2541 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2542 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2543 300 mm sweep 1300 rpm 2544 cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia pvc pipe conforming bis-12818 and making good the same etc. complete as per direction of engineer-in-charge. 2545 lightning conductor 2546 providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, g.i. tube, having single prong at top, with 85 mm dia 6 mm thick g.i. base plate including holes etc. complete as required. 2547 fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 2548 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 2549 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 2550 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2551 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2552 providing and fixing testing joint, made of 20 mm x 3 mm thick g.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chuck nuts and spring washers etc. complete as required. 2553 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. details of cost for one set 2554 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 2555 cost of type- 4 2556 structural repair & retrofitting 2557 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 2558 50 mm average thickness 2559 25 mm average thickness 2560 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 2561 bars upto 12 mm diameter 2562 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 2563 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 2564 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 2565 25mm thick in grade m 25 with cement content not less than 330 kg per cum 2566 50mm thick in grade m 25 with cement content not less than 330 kg per cum 2567 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 2568 repairs to roof 2569 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2570 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2571 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2572 repair to toilets 2573 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 2574 for thickness of tiles 10 mm to 25 mm 2575 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2576 repair to plaster and plinth protection 2577 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2578 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2579 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2580 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2581 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2582 with cement mortar 1:4 (1cement: 4 coarse sand) 2583 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2584 15mm cement plaster on rough side of single or half brick wall of mix 2585 1:6 (1 cement : 6 course sand) 2586 6mm cement plaster to ceiling of mix : 2587 1:3 ( 1 cement : 3 fine sand) 2588 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2589 two coats 2590 distempering with 1st quality acrylic distemper (ready made) having voc content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 2591 one or more coats on old work 2592 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2593 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2594 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2595 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2596 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2597 repairs to door / windows 2598 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2599 of area 3 sq. metres and below 2600 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2601 of area 3 sq. metres and below 2602 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2603 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2604 renewal of old putty of glass panes (length) 2605 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2606 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2607 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2608 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete fixed to steel windows by welding 2609 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2610 300 mm weighing not less than 200gms. 2611 250 mm weighing not less than 150gms. 2612 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 2613 100x58x1.90 mm 2614 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2615 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2616 300 x 10mm 2617 150 x 10mm 2618 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2619 125 mm 2620 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 2621 twin rubber stopper 2622 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 2623 providing and fixing to existing door frames. 2624 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 2625 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2626 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2627 with isi marked stainless steel butt hinges of required size 2628 kiln seasoned and chemically treated hollock wood 2629 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2630 with 12 mm mild steel u beading 2631 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2632 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2633 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2634 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2635 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2636 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2637 4.0 mm thick glass panes 2638 applying priming coat : 2639 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 2640 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2641 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2642 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2643 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2644 one or more coats on old work 2645 repairs to flooring 2646 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2647 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2648 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 2649 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 2650 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 2651 25 mm thick 2652 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 2653 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 2654 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 2655 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 2656 miscellaneous 2657 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2658 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2659 cement mortar 1:6 (1 cement : 6 coarse sand) 2660 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2661 cement mortar 1:4 (1 cement :4 coarse sand 2662 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2663 plumbing work of type-4 2664 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2665 75 to 80 mm dia pipe 2666 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2667 15 mm to 40 mm nominal bore 2668 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2669 up to 150 mm diameter 2670 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2671 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2672 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2673 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 2674 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2675 up to 150 mm diameter 2676 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2677 rectangular manhole 90x80 cm and 45 cm deep 2678 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2679 110 mm diameter 2680 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2681 a) coupler 2682 110 mm 2683 b) bend 87.5° 2684 110 mm bend 2685 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 2686 75 mm diameter pipes 2687 100 mm diameter pipes 2688 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2689 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2690 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : 2691 w.c. pan with isi marked white solid plastic seat and lid 2692 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2693 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2694 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2695 kitchen sink without drain board 2696 610x510 mm bowl depth 200 mm 2697 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2698 a) 32mm dia (for wash basin) 2699 b) 40mm dia (for sink and urinal) 2700 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2701 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2702 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2703 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2704 providing & fixing c.p. brass waste coupling for pvc waste pipe. 2705 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2706 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2707 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2708 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2709 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2710 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2711 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2712 p-trap type floor trap 110 x 75 mm 2713 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2714 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2715 providing and fixing 100 mm sand cast iron grating for gully trap. 2716 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2717 providing & fixing soil, waste and vent pipes. 2718 a) 100mm dia centrifugally cast iron s & s pipe. 2719 b)75mm dia centrifugally cast iron s & s pipe. 2720 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 2721 a) for 100mm dia pipe. 2722 b) for 75mm dia pipe. 2723 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 2724 a) 100mm 2725 sand cast iron s&s as per is - 3989 2726 b) 75mm 2727 sand cast iron s&s as per is- 3989 2728 providing and fixing plaincast iron s & s sanitary bend. 2729 a) 100mm 2730 sand cast iron s&s as per is - 1729 2731 b) 75mm 2732 sand cast iron s&s as per is - 3989 2733 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 2734 a) 100x100x100mm 2735 b) 75x75x75mm 2736 providing and fixingcast iron terminal guard. 2737 a) 100mm 2738 b) 75mm 2739 providing & fixingcast iron coller. 2740 a)100 mm 2741 sand cast iron s&s as per is - 3989 2742 b)75mm dia. 2743 sand cast iron s&s as per is - 3989 2744 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 2745 a) 100mm 2746 b) 75mm 2747 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 2748 a) 100mm inlet & 75mm outlet. 2749 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2750 15 mm nominal outer dia pipes 2751 20 mm nominal outer dia pipes 2752 25 mm nominal outer dia pipes 2753 32 mm nominal outer dia pipes 2754 providing and fixing brass stop cock of approved quality. 2755 15 mm nominal bore 2756 providing and fixing gun metal gate valve with wheel of approved quality. 2757 a) 25mm dia nominal bore 2758 b) 32mm dia nominal bore 2759 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2760 a) 25mm. nominal bore 2761 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2762 a) 15mm nominal bore 2763 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2764 a) 15mm nominal bore 2765 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2766 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2767 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2768 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2769 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2770 a) 15mm nominal bore 2771 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2772 a) 15mm nominal bore 2773 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2774 a) 15mm nominal bore 2775 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2776 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2777 25mm nominal bore, weighing not less than 62 gms 2778 cutting holes up to 30x30 cm in walls including making good the same: 2779 with common burnt clay f.p.s. (non modular) bricks 2780 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2781 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2782 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2783 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2784 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2785 electrical work of type-4 2786 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2787 group b 2788 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2789 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2790 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2791 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2792 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2793 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2794 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2795 group b 2796 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2797 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2798 2 x 1.5 sq. mm 2799 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2800 25 mm 2801 32 mm 2802 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2803 100 mm x 100 mm x 60 mm deep 2804 150 mm x 75 mm x 60 mm deep 2805 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2806 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2807 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2808 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2809 supplying and fixing brass batten/ angle holder including connection etc. as required. 2810 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2811 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2812 6 way, double door 2813 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2814 4 way (4 + 12), double door 2815 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2816 single pole 2817 single pole and neutral 2818 triple pole 2819 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2820 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2821 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2822 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2823 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2824 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2825 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2826 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2827 upto 450 mm sweep 2828 supply of 15w surface mounted round led with all accessories as per standard item.. 2829 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2830 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2831 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2832 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2833 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2834 300 mm sweep 1300 rpm 2835 cost of workshop 2836 repairs to roof 2837 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 2838 asbestos cement sheet 2839 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 2840 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 2841 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 2842 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 2843 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 2844 repair to plaster and plinth protection 2845 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2846 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2847 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2848 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2849 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2850 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2851 with cement mortar 1:4 (1cement: 4 coarse sand) 2852 12mm cement plaster of mix : 2853 1:6 (1 cement : 6 course sand) 2854 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2855 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2856 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2857 old work (one or more coats) 2858 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2859 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2860 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2861 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2862 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2863 miscellaneous 2864 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 2865 in cement mortar 2866 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2867 cement mortar 1:6 (1 cement : 6 coarse sand) 2868 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2869 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2870 75 to 80 mm dia pipe 2871 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2872 110 mm diameter 2873 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2874 a) coupler 2875 110 mm 2876 b) bend 87.5° 2877 110 mm bend 2878 electrical cost of workshop 2879 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2880 group c 2881 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2882 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2883 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2884 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2885 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2886 2 x 1.5 sq. mm 2887 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2888 25 mm 2889 32 mm 2890 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2891 100 mm x 100 mm x 60 mm deep 2892 150 mm x 75 mm x 60 mm deep 2893 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2894 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2895 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2896 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2897 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2898 6 way, double door 2899 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2900 4 way (4 + 12), double door 2901 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2902 single pole 2903 single pole and neutral 2904 triple pole 2905 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2906 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2907 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2908 upto 450 mm sweep 2909 supply of 15w surface mounted round led with all accessories as per standard item.. 2910 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2911 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2912 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2913 supply of 30w led recess mounted fixturemake-philips cat no.rc380b led30s-6500 l60w60 psd od s1 or equivalent. 2914 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2915 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2916 450 mm sweep 1400 rpm 2917 electric sub station 2918 repairs to roof 2919 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2920 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2921 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2922 repair to plaster and plinth protection 2923 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2924 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2925 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2926 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2927 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2928 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2929 with cement mortar 1:4 (1cement: 4 coarse sand) 2930 12mm cement plaster on rough side of single or half brick wall of mix 2931 1:6 (1 cement : 6 course sand) 2932 6mm cement plaster to ceiling of mix : 2933 1:3 ( 1 cement : 3 fine sand) 2934 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2935 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2936 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2937 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2938 one or more coats on old work 2939 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2940 two coats 2941 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2942 old work (one or more coats) 2943 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2944 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2945 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2946 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2947 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2948 repairs to door / windows 2949 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2950 of area 3 sq. metres and below 2951 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2952 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2953 renewal of old putty of glass panes (length) 2954 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer. 2955 using flats 30x6mm for diagonal braces and central cross piece 2956 miscellaneous 2957 providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia m.s. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with m.s. tubes, m.s. tube challies, m.s. clamps and m.s. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .the scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of engineerin-charge .the elevational area of the scaffolding shall be measured for payment purpose .the payment will be made once irrespective of duration of scaffolding. note: - this item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 2958 anti-termite treatment 2959 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2960 110 mm diameter 2961 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2962 a) coupler 2963 110 mm 2964 b) bend 87.5° 2965 110 mm bend 2966 pump room. 2967 repairs to roof 2968 repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (dr. fixit make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge.with cement mortar 1:4 (1cement: 4 coarse sand) 2969 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2970 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2971 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2972 repair to plaster and plinth protection 2973 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2974 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2975 with cement mortar 1:4 (1cement: 4 coarse sand) 2976 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2977 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2978 15mm cement plaster on rough side of single or half brick wall of mix 2979 1:6 (1 cement : 6 course sand) 2980 6mm cement plaster to ceiling of mix : 2981 1:3 ( 1 cement : 3 fine sand) 2982 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2983 one or more coats on old work 2984 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2985 two coats 2986 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2987 old work (one or more coats) 2988 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2989 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2990 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2991 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2992 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2993 repairs to door / windows 2994 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2995 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2996 renewal of old putty of glass panes (length) 2997 miscellaneous 2998 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 2999 in cement mortar 3000 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 3001 110 mm diameter 3002 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 3003 a) coupler 3004 110 mm 3005 b) bend 87.5° 3006 110 mm bend 3007 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 3008 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 3009 sewerage system 3010 excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 3011 all kinds of soil 3012 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 3013 pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 3014 providing and laying non-pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 3015 150 mm dia. r.c.c. pipe 3016 450 mm dia. r.c.c. pipe 3017 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40 mm nominal size) 3018 150 mm diameter s.w.pipe (l*.35*.10) 3019 450 mm diameter s.w.pipe (l*.6*.15 ) 3020 constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with rcc top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 3021 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 3022 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 3023 extra for depth for manholes: 3024 size 90 x 80 cm 3025 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 3026 constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with fps bricksclass designation 75in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 3027 0.91m deep with sfrc cover and frame (heavy duty hd-20 grade designation) 560mm internal diameter conforming to i.s:12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) 3028 with common burnt clay f.p.s.(non module) brick of class designation 7.5 3029 extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . 3030 with common burnt clay f.p.s.(non module) brick of class designation 7.5 3031 providing and fixing square mouths. w. gully trapclass sp-1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 3032 180 x 150 mm. size p type 3033 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 3034 providing m.s. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 3035 with 20x20 mm square bar 3036 cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 psi for sewer line from 150mm dia upto 300mm 3037 cleaning and desilting of gully trap chamber, including removal ofrubbish mixed with earth etc. and disposal of same, all as per thedirection of engineer-in-charge. 3038 cost of entrance gate 3039 earth work 3040 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.all kinds of soil 3041 extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.all kinds of soil 3042 concrete work 3043 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zoneiii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 3044 providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii): 4 graded stone aggregate 12.5mm nominal size) 3045 providing & applying a coat of residual petroleum bitumen of grade of vg-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 3046 reinforced cement concrete 3047 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 3048 upto plinth level 3049 (i) r.c.c. work in footing 3050 (ii) r.c.c. work in beam 3051 (iii) r.c.c. work in columns 3052 above plinth to floor-v lvl 3053 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 3054 (i) r.c.c. work in beam 3055 (ii) r.c.c. work in columns 3056 (iii) r.c.c. work in slab 3057 centering and shuttering including strutting, propping etc. and removal of form for all heights : 3058 foundations, footings, bases of columns, etc. for mass concrete. 3059 columns,pillars, piers, abutments, posts and struts. 3060 suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 3061 lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 3062 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500d or more. 3063 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. thermo-mechanically treated bars of grade fe-500 d or more. 3064 masonry work 3065 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : cement mortar 1:6 (1 cement : 6 coarse sand) 3066 wood and pvc work 3067 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including isi marked stainless steel butt hinges with necessary screws. 3068 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. fixed to steel windows by welding. 3069 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. twin rubber stopper 3070 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete(a) 125 mm. 3071 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 3072 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 3073 300 x 10mm 3074 200 x 10mm 3075 steel work 3076 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 3077 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 3078 steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 3079 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 3080 flooring 3081 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 3082 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 3083 finishing 3084 12 mm cement plaster on the fair side of single or half brick wall (a) 1:6 (1 cement: 6 coarse sand) 3085 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). 3086 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 3087 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 3088 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work (two or more coats) over and including water thinnable priming coat with cement primer. 3089 finishing walls with water proofing cement paint of required shade : new work (two or more coats applied @ 3.84 kg/10 sqm) 3090 applying priming coat: 3091 with ready mixed aluminium primer of approved brand andmanufacture on resinous wood and plywood 3092 with ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 3093 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 3094 finsihing with epoxy paint (two or more coats) at all locations pepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.on steel work. 3095 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 3096 water proofing 3097 painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 3098 supply & fixing of prepainted coloured trapezoidal or approved profiled sheeting 1000-1020 mm cover width, 28-30 mm high crests with subtle square fluting in the five pan at nominal 190-255 mm (as approved by eic) centre-to-centre manufactured out of 0.50 mm tct hi-tensile prepainted zincalume /galvalume steel (az-150 gsm. aluminium –zinc alloy metallic coating of total both sides 550 mpa yield stress as per as-1397). colour/ exterior coat of rmp 20 micron top coat applied over 5 micron primer and a 5 micron polyester back coat applied over 5 microns primer or equivalent coating/painting. the sheet shall have wide pans with stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlin support. the male end of the sheet shall have anti-capillary flute at side laps to prevent leakages. the sheet shall be fixed by means of anti corrosive approved make rust shield (epoxy polymer) coated self-drilling self tapping fasteners 12-14 x 55 mm with epdm seals through crest for roofing and 12-24 x 20 mm through valley (pans) for wall cladding. the sheet shall be supplied in lengths maximum up to 6-12 meter long to suit site dimensions. the scope includes all sealing of joint, curves, edges or other accessories with silicon sealant. 3099 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 3100 electricalworksmain gate 3101 sub head - i: circuit cum point wiring 3102 switch control light points 3103 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 3104 group c 3105 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required. (switch control secondary points) 3106 group c 3107 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. (switch control primary points) 3108 group c 3109 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutindependent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required. (switch control secondary points) 3110 group c 3111 mcb control light points 3112 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. (switch control primary points) 3113 primary point controlled by one mcb. 3114 same as item above but secondary point. i.e. points to be looped with primary pointwith 2.5 sqmm wire and point wiring 3115 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 3116 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 3117 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 3118 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 3119 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 3120 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 3121 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 3122 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 3123 supplying and fixingsuitable size gi box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 amp modular socket outlet and 5/6 a modular switch, connection etc. as required. 3124 supply and wiringfor 250 volts singlephase and neutral 2 nos 6 amps socket outlate with control by 1 no switched with 2.5 sq.mm pvcinsulatedcopper conductor1100 volts grade stranded flexible frls wires inconcealed or surface mounted 25 mm dia 2mm thickpvc conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick gi box with grid plate and earthingofthird pin of the socket with2.5sq. mm pvc insulated copper conductor strandedflexiblefrlswire.(maximum four no. of switches socket shall be connected on onecircuit) 3125 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 3126 supplying and fixing 63 a, 415 v, tpn industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 3127 supplying and fixing 80 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 3128 supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required. 3129 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 amps modular sp mcb, “c” curve including connection, painting etc. as required. (acs & gysers) 3130 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3131 telephone socket outlet 3132 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 3133 1 or 2 module (75mmx75mm) 3134 6 module (78mm x 205 mm x 50 mm) 3135 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 3136 3 pin , 5/6 amps socket outlet 3137 5/6 amps switch 3138 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 3139 25 mm 3140 32 mm 3141 subhead -ii - fittings & fixtures 3142 supply, installation, testing and commissioning of 10 w bulk head light. 3143 supply, installation, testing and commissioning of 5w mirror light. 3144 supply, installation, testing and commissioning of 18w surface/recessed mounted led circular downlighter. 3145 supply, installation, testing and commissioning of 18/20w wall/surface mouted 4 ft. led 3146 supply, installation, testing and commissioning of 15wsurface mountedled square downlighter. 3147 supply, installation, testing and commissioning of 12/9wrecessed mountedled circular downlighter. 3148 supply, installation, testing and commissioning of9w (nominal)wall bracket light 3149 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019),thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 3150 supplyinstallation, testing and commissioning of 250 mm dia domestic exhaust fan 3151 subhead - iii - distribution boards 3152 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 3153 6 way, double door 3154 8 way, double door 3155 12 way, double door 3156 supplying and fixing following way, three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (but without mcb/ rccb/ isolator) 3157 4 way (4 + 12), double door 3158 6 way (4 + 18), double door 3159 8 way (4 + 24), double door 3160 supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer) as required . (note :vertical type mcb tpdb is normally used where 3 phase outlets are required.) 3161 12 way (4 + 36), double door 3162 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 3163 single pole 3164 single pole neutral 3165 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 3166 40 a 3167 63 a 3168 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 3169 25 a 3170 40 a 3171 63 a 3172 supplying and fixing following rating, double pole, (single phaseand neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 3173 25 a 3174 40 a 3175 63 a 3176 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 3177 basket ball court 3178 for one no. of court 3179 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per directionof engineer - in - charge nominal concrete 1:3:6 or richer mix 3180 providing and laying c.c. pavement of mix m-25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer-incharge. (the panel shuttering work shall be paid for separately). (note:- cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 3181 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 3182 thermo-mechanically treated bars of grade fe-500d or more. 3183 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 3184 40 mm thick with 20 mm nominal size stone aggregate 3185 providing and fixing ac strips in joints ofcement concrete floors.70 mm wide and 4 mm thick. 3186 finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. 3187 on steel work: (on poles) 3188 vertical member (8in dia & 3.2 m long) 3189 horizontal member (8in dia & 2.5 m long) 3190 ugt with pump house 3191 cost of under ground sump 3192 cost of 2 set of 7.5 hp submersible pump (i.e. rs 75,000, each) including all control panel and fitting charges, etc. 3193 external electrical work 3194 subhead - i - main boards 3195 meter boards 3196 supply, installation, testing and commissioning of m.v. cubical type totally enclosed dust, dump and vermin proof meter bords complete with bus bars, mv danger notice plate, on surface isi marked electronic kwh meter, indication lamps, cts, interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingmcbs mccbs and kwh meters complete as required. 3197 panel- kitchen dining 3198 incomer 3199 1 no.40 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3200 metering & indication 3201 1 set of r,y,b phase indicating lamps 3202 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 40/5a cts (40a/500v) rating 3203 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3204 bus-bar 3205 1 set of 50a tpn aluminium bus bar with colour coded pvc sleeves 3206 out going: 3207 2 nos. 25a tpn mcb of 10ka 3208 3 no. 40a dp mcb of 10ka. 3209 supplying,receiving, fixing, testing & commissioning ofabove described panel 3210 meter boards - type-iii, type ii & type i 3211 incomer 3212 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3213 metering & indication 3214 1 set of r,y,b phase indicating lamps 3215 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3216 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3217 bus-bar 3218 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3219 out going: 3220 4 nos. 40a tpn mcb of 10ka 3221 2 nos. 40a dp mcb of 10ka. 3222 supplying,receiving, fixing, testing & commissioning ofabove described panel 3223 meter boards -dormitory boys & girls 3224 incomer 3225 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3226 metering & indication 3227 1 set of r,y,b phase indicating lamps 3228 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3229 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3230 bus-bar 3231 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3232 out going: 3233 4 nos. 40a tpn mcb of 10ka 3234 2 nos. 40a dp mcb of 10ka. 3235 supplying,receiving, fixing, testing & commissioning ofabove described panel 3236 meter boards - vice principle residence, guest house, workshop & gym 3237 1 no.40amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3238 panel -school building & mp hall 3239 incomer 3240 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3241 metering & indication 3242 1 set of r,y,b phase indicating lamps 3243 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3244 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3245 bus-bar 3246 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3247 out going: 3248 4 nos. 40a tpn mcb of 10ka 3249 3 no. 40a dp mcb of 10ka. 3250 supplying,receiving, fixing, testing & commissioning ofabove described panel 3251 subhead - ii - earthing 3252 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 3253 earthing with cu. earth plate 600mm x 600mm x 3mm thick includingaccesssories, and providingmasonary enclosurewith cover plate (ci heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required. 3254 supplying and laying 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode, including connection with g.i. nut, bolt, spring, washer excavation and refilling etc. as required. 3255 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 3256 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 3257 cost of septic tank [for repairing of existing septic tank]
  • View Tender
  • Document
  • Bid Support
5 Security Services
image image
Central Government/Public Sector
TRN :49068734 |  28 May, 2025
Tender Value : 40.00 Lacs
 Bikaner - Rajasthan
Tender for tender for certain repair to buildings of wsa at af stn nal; 1 demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for allas specified and directed. 2 m&l for cement concrete type d2 (1:4:8) ( 40 mm graded crushed stone aggreagte) as filling and mass concretecomplete all as specified and directed. 3 m&l for laying 100mm thick cement concrete type b-1(1:2:4) ( 20 mm graded crushed stone agg)as in floor and paving surfaces all as specified and directed. 4 demolition of brick workor stone/boulders masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars etc. and rubbish materials remove from site all as specified and directed 5 m&l for brick work with sub class b bricks (old size) straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed by engr-in-charge. 6 taking down cement plaster of any description on brick/stone walll incl raking out joints hacking for keyscrubbing down water all as speicifed. 7 m&l for rendering 15 mm thickin cement plaster (1:6) on fair faces of brick/concrete surface, finishing even and smooth w/o using extra cement etc. 8 m&l for rendering 15mm thick in cement mortar (1:4) on brick or concrete wall surface finished even and smooth without using extra cement. 9 m&l for preparing newly plastered wall surfaces and applying two coats of weather proof exterior emulsion over and including one coat of primer complete all as specified and directed by engr-in-charge. 10 m&l for preparation of newly plastered surfaces of wallsand applying two coats of oil bound distemper over and including a coat of primer incl etc. complete all as specified and as directed. 11 m&l for preparation of old decorated surfaces of walls (plastered or un plastered) including cornices, pilaster etc by brooming down with steel wire brushing, scrapping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including filling the depressions with cement based wall care putty and applying one coat of oil bound distemper complete all as specified and directed. 12 m&l for preparation of old painted surface ofwall surface and applying one coat ofweather proof exterior emulsion in camouflage pattern to match the existing pattern complete all as specified and diricted by engineer-in-chare. 13 rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified . 14 removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed at a level n.exc 1.5m above starting point complete all as specified and directed by engr-in-charge. 15 forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed by engr-in-charge. 16 allas per item no-15 (here-in-before) but 1.5m to 3m height from base completeall as specified and directed by engineer-in-charge. 17 allas per item no-15 (here-in-before) but 3m to 4.5m height from base completeall as specified and directed by engineer-in-charge. 18 allas per item no-15 (here-in-before) but 4.5m and above height from base completeall as specified and directed by engineer-in-charge. 19 dismantling posts or struts in natural ground (wood, steel or r.c.c.) any section, including taking out embedded portion and making good disturbed groundcomplete all as specified and directed by engr -in-charge. 20 excavation in post holes(or similar holes) each in not exc. 0.50 cum getting out returning,filling in an ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm watering and removing surplus soil out of defence land and making good surface all as specified & directed. 21 m&l for pcc(1:3:6) type c2 (40mm graded crushed stone aggregate) filling in post holes, foundation,and other similar work complete all as specified and as directed. 22 s & f hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to fe 410-0 or fe 310-0 23 dismantling fencing wire mesh, any type etc, complete all as specified and as directed. 24 s&f in repair galvanised 2 strand , steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixingto any type of standard railsstraining bolts, including securing ortyping at crossingswith andprovision of galvasnised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured), complete all as specified and as directed. 25 fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire 26 supply only galvanised mild steel chain link fencing, size wire and mesh as approved complete all as specified and directed.note:- the payment for chain link fencing shall be made on the basis of weight of chain link fencing per square metre ascertained by a board of officer convened by ge, by getting minimum 3 samples of each lot . 27 m&l for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applied two coats of synthetic enamel paint over and including a coat of red oxide zinc chrome primer complete all as specified and directed by engr -in-charge. 28 dismantling timber scantlings 40 sq. cm and over in section, in any position in framed section etc., complete all as specified and as directed. 29 dismantling of wrought iron or mild steel work of any description not ohterwise provided for complete all as specified and directed. 30 m&l for ms work in roof trusses (framed), trussed, purlins, crane gantries, rails, posts and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.including special shaped washer etc. complete and including all necessary drilling or cutting holes in brick/ concrete surfaces and making good by pcc and cement plaster, welding work, bolting or reveting/fastening with fastner etc and similar work conforming to fe-290 gde e-165 complete and all as specified 31 s&f ms plain plates, square cut, with riveted, bolted or welded attachment fe-410-w (gde-e-250) quality a as specifed 32 s&f mild steel screw bolts (machine made) with hexabonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc 5cm long, diameter of neck in 5 to 10mm. 33 dismantling asbestos cement (corrugated,semicorrugated, etc.) sheets in roofcoverings including ridges complete all as specified & directed. 34 s & f pre- painted galvalume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 35 dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering etc. 36 s & f 1mm thic plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters,(joints should be water tight) drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc. 37 supply and laid in repairs 110mm bore pvc (swr) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors etc. 38 s& f in repairs pvc (swr) bends for 110mm bore pipe etc. 39 taking up or down 15 mm dia steel tubing & connections or removal to store etc. 40 s & f 15mm bore of tube medium grade galvanized with and including all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed. 41 dismantling water tanks any type of capacityexc 1000 but n.exc 2000 liters 42 dismantling water tanks any type of capacityexc 250 but not exc 500ltr 43 s&f 1000 liter capacity rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) tripple layered white, hoisted and fixed in position with and including 20 mm bore ball valves high pressure of ptmt with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. 44 s&f 500 liter capacity rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) tripple layered white, hoisted and fixed in position with and including 20 mm bore ball valves high pressure of ptmt with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. 45 s&f in repair 15mm bib taps quarter turn, cast copper alloy , with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed etc. 46 taking down door shutters of any description exc 2sqm complete all as specified. 47 taking down old wooden doors (single/double shutter ) of exc 4sqm n.exc 6sqm any position with complete accessories including chowkhat or frame all as specified and directed by eic. 48 taking down chowkhats or frames or ventilator not exc. 1.5 sq. m each etc. 49 s & f framed work as in doors, gates and ventilators of angle or other sectionfe-410 w (gde e-250) quality a with gusset plates, ms plain black sheet for door, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. 50 s & f expanded metal, weight not exc 4kg per sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members 51 s & f mild steel flat iron as in hold fast 400mm long embeded in pcc block with splitted ends and in braces in diagonal hand made sliding bolts, clamp hooks and similar worklike banks, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; largehasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to fe410-0 or fe 310-0 52 m & l for pcc (1:2:4)type b1 (20mm graded stone aggregate )asin lintels upto 1..5 m clear span, cills, hold fast for door, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing 53 s&f 35 mm thick 2nd class hardwood, plain, framed, factory made panelled shutters (any number of panels), in with panels of timber flat on both sides (feather edged), of 12 mm bwp commercial ply with commercial veneering on both faces; supplied and fitted to chowkats 54 material and labour for preparation of new wood surfaces of any description not other described over 10cm width or girth and applying twocoats of synthetic enamel paintover and including a coat of pink primer complete all as specified and directed. 55 supply and fixing in repair mild steel butt hinges medium weight, cold rolled, 100mm, isi marked, fixed with stainless steel screws complete all as specified and directed. 56 supply and fixing 150mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. 57 supply and fixing 150 mm size extruded aluminium alloy handels fabricated type, anodised fixed with stainless steel screws complete all as specified and directed. 58 supply and fixing 300mm aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) fixing clips of sheet, cast or extruded setions and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed with stainless steel screws complete all as specified and directed. 59 m&l for providing post construction anti termite treatment to soil under existing floors using chemicalemulsion @ one litre per hole, 300 mm apart along the junction of floor and wall including drilling 12 mm dia holes and plugging with cement sand mortar (1:2) using pigment wherever required, to match the existing floor surfaces complete all as specified and directed.note :-any crack which is developed during execution of att in the floor shall be repaired to match the surface.the cost of this aspect shall deemed to be included in the rates quoted by the contractor 60 m&l for providing post construction anti termite treatment by specified firm along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre i.e. holes @300mm interval including drilling and plugging holes etc in apron/plinth protection and making good the surfaces to match complete all as specified and directed. 61 m&l for providing post construction anti termite treatment by specified firm to voids in masonry using chemical @ one litre per holes at 300 mm intervals by drilling holes at downward angle of 45 degree and replugging them with cement mortar 1:2 to match the existing surface complete all as specified and directed. 62 s&f in repair vitreous china wash down water closet pan pedestal pattern ( type white including pvc seat cover , connection to waste pipe and flushing pipe complete etc. 63 s & f in repair 10 ltr capacity pvc valveless syphonic action type flushing cistern low level white with inlet ball valve and brackets,float and handle, l-bend complete all as specified and directed 64 s&f in repairs vitreous china wash basin, white, flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper but including bracket complete all as specified and directed 65 s & fvitreous china urinals, bowl type (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and union for discharge pipe.fixed in repairs complete all as specified and directed. 66 s & f urinal spreader of ptmt any colour for fixing with 15 mm dia pipe. (minimum weight 60gms) 67 s & f health faucet (abs body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and abs wall hook including making connections and fixed in position complete in all respect as specified. 68 s & f in repair long body stop valve 15mm bore(quarter turn) fancy type chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions. 69 s&f in repairs 15mm bore pvc connection pipe 450mm long with ptmt nuts at both ends etc.
  • View Tender
  • Document
  • Bid Support
6 Construction
image image
State Government
TRN :49020462 |  15 May, 2025
Tender Value : 0
 Akola - Maharashtra
Tender for rate call for ( non dsr) items preparing estimate of under honble balasaheb thackeray haridra research and traning centre,vasmat,dist.hingoli =2 providing & fixing on site 75 mm thick reflexology ( pebbles ) stone flooring etc complete 3 providing & laying of hdpe pond liner of 750 micron thickness as per manufacturer’s specification & instructions from engineer in charge etc. complete. 4 orientation signage pole :- providing & fixing of orientation signage pole made up of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), with the size of 12x4inner frame and 60mm dia for support structure made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. the structure will be illuminated from within. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 5 identification signage pole :- providing & installation of identification signage pole made up of marine quality composite from 60mm dia for support structure {marine grade corrosion resistant & hydrocarbon solvent resistant) with all fittings fixture, hardwares , all as per design & drawings with all fittings, fixtures etc. complete , with the size of 6x1.5inner frame made of mild steel pipe od 60mm as the main support section is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 6 directional signage -5m single arm frp pole with haldi banner and leaf (signage): the single arm pole shall be made of 68 mm dia with metal hot dipped galvanized pipe support inside the frp cladded pole. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of is:3601 or equivalent, hotdip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted which usually require maintenance and care. pride suspended luminaire: 50 watt led suspended luminaire with height 450mm and width 500mm. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 7 directional signage post :-providing & fixing of directional signage post (signage) with 5ft height and 700mm wide post and 48 mm dia support pipe with frame having and metal frame to show the directional or location of certain area. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer incharge etc. complete on site. structural stability certificate will be givenv 8 haldi information post :- providing & fixing of haldi information post- farming (signage) with 5ft height and 700mm wide and 48 mm dia support pipe with frame having a metal frame work to be used for provided information regarding the harida haldi project and which type of haldi crop grown on the particular field. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. item is also including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete. 9 pergolas type 1:- providing & fixing of type 1 pergolas with frp column 200mm x 200 mm in ms fabrication use in 88.2 od ms pipe 3 mm thickness. frp beam size 150 mm x 150 mm in ms fabrication 40 mm x 40 mm x 2 mm thickenss tube in framing. frp support for beam and column use in 75 mm x 75 mm x2 mm ms tube with frp cladding. frp thickness minimum 3 to 4 mm . column fittng in 12 mm x 150 mm anchor bolt in foundation. including installation machineries, scaffoldings, electricity, other site utilities in client scope. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structure stability certificate will be provided etc complete 10 pergolas type 2( for seating areas ):- providing & fixing of type 2 with frp column 200mm x 200 mm in ms fabrication use in 88.2 od ms pipe 3 mm thickness . frp beam size 150 mm x 150 mm in ms fabrication 40 mm x 40 mm x 2 mm thickness tube in framing. frp support for beam and column use in 75 mm x 75 mm x2 mm ms tube with frp cladding. frp thickness minimum 3 to 4 mm . column fitting in 12 mm x 150 mm anchor bolt in foundation. including installation machineries, scaffoldings, electricity, other site utilities in client scope. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. type 2 (for seating areas ). item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structure stability certificate will be provided etc complete. 11 providing & fixing of type 01 module ( with back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made in combination of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 12 providing & fixing of type 02 module ( without back rest) frp seating with pvc wooden panel bench should be made in combination of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life . item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 13 providing & fixing of type 01 module ( with back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 14 providing & fixing of type 02 module ( without back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 15 dustbin frp dustbin should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant) all weather proof & maintenance free with long design life. the product should be 700 x 500 frp planter with basic design and 40 x 20mm sq. pipe to support the section of dustbin. it should be selfcolored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 to 4 mm average with sizes 2000x600 mm. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 16 providing & placing at position type1 of 700mm x 305mm frp plantershould be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should be 700 x 305 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage shall be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 17 providing & placing at position type2 of 610 mm x 254 mm frp planterfrp planter should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should 610 x 254 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 18 providing & placing at position type3 of 510 x 200 frp planter frp planter should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should 510 x 200 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 19 tree grating:- providing & fixing of frp tree grating of size 1100 x 1100 x 25 mm frp material with various design options. made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), the product should be an all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. as per design & drawings with all fittings, fixtures etc. complete. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site.. 20 custom design, supply & installation /surfacing of epdm 6 mm & 19 mm rubber crumbs at site etc complete 21 providing & fixing of tumble twin with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 22 providing & fixing of animal mgr with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 23 providing & fixing of deluxe junior see saw with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 24 providing & fixing double post swing with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site etc complete 25 providing & fixing duck rider with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 26 providing & fixing fun walker single with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 27 providing & fixing step trainer with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 28 providing & fixing chest press double with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 29 providing & fixing shoulder press double with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 30 providing & fixing tai chi cum standing twister with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 31 providing & fixing leg press cum parallel bar with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 32 providing & fixing leg press cum seating twister with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 33 providing & fixing of cobble stone of basalt 100 mm x 100 mm & 40 to 50mm thick etc complete 34 providing, fixing & installation of 18mm thick grc ( glass reinforcedconcrete ) of high quality iso grade upto 2.4 mtr height with 18mm grc chopped strands includingpure white cement , silica sand for finishingwith coating of sbr liquid or equivalent chemical for bonding work with all fittings, fixtures hardwares, wax polishing, caster, fitter, labour charges, scaffolding etc. complete as per design, drawings & manufacturer’s specification also as per instructions from engineer in charge etc. complete. sbr liquid will be used for bonding of various materials of the structure which also helps in waterproofing and adhesion giving it a long life durability specially multi dies will be made using cnc machine giving it a high precession for the design of the structure. material is made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant). its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life including structural stability certificationetc complete. 35 providing, fixing & installation of 4 mm thick frp ( fiber reinforced polymer) material high quality iso grade. frp material placed above grc of high quality iso grade material as per design, drawings & as per manufacturer’s specification & instructions from engineer in chargeincluding all hardener, fittings, fixtures, welder, patch work,labours charges, scaffolding etc. complete . the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life including structural stability certification etc complete. 36 providing & applying weather finish coating & lackering of 100microns to all surfaces of grc & frp with all rubbing, finishingwith all equipments, labours, scaffolding all as per design, specification & instructions from engineer in charge etc. complete 37 waterproofing cum insulation composite system:-cleaning the surface to make it dust free andsludge free, removing any extended portions by grinding and if required using suitable equipment’s and should be totally dry & have proper slope for free flow of water preparing the surface by spray applying a coat of bitumen primer @0.25-0.35kg/square metre over the entire dust free surface. providing and applying single layer of ultraplast b app- 4mm (atactic polypropylene polymer) modified water proofing membrane reinforced with non-woven polyester matt 160+20 g/m2 having polymer film as a top surface. minimum tensile strength in longitudinal and transverse direction as 750n +150 / 600n +120/5cm (astm d 5147). minimum nail shank tear resistance in longitudinal and transverse direction as 300/300n + 100 n (astm d 4073) elongation in longitudinal and transverse direction 40+8% / 45+9%. softening point of membrane not less than 150 + 5 degree celsius consisting of a coat of technonicol bitumen primer no 01 primer @ 0.25- 0.35 ltr./sq.mtr with a relative viscosity of 15-40 s,. over the primer coat, the layer of membrane shall be laid using butane / lpg torch and sealing all joints with minimum 75 mm side laps & 100 mm end laps to form a monolithic system. the laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane etc complete. 38 providing and laying leed certified carbon prof 300 extruded polystyrene 50mm thick having thermal conductivity of 0.028 w/mk (astm c 177) with compressive strength of > 300 kpa (astm d 1621 en 826) and density of 30-35 kg/m3. long term water immersion astm c 272 (en12087) < 0.7% over the waterproofing membrane having shiplap arrangement. work shall be done through the authorized applicator of the manufacturer of the insulation boardetc complete. 39 prviding & fixing glassreinforced concrete (grc)25mm jali as per deign & details etc completed. 40 providing and fixing heavy gauge galvinsed iron 50”fan with autoopening 10shutters, drop hamper exhaust fan systems with 6 no.ss blades with low noise , cfm:-25890, auto opening shutters damper type 415v,50hz, 1.5hp motor, 3hp with fitting etc complete.cellulose cooling pad 1200mmx600mmx100mmt one pad contain area of 1 0 sqft, leading kit with pipeline upto frame,- bypass, filter flush system etc.6”aluminum frame for the above coolingpads with top water distribution and bottom gutter, aluminum 41 providing & fixing air circulation fans 7 blades ss aluminum powder coated of model gtacf-40-70, size of d320mmxh400, 50hz , 1400 rpm, 220v, 120w, single phase, 70 ft airflow etccomplete. 42 automatictemp humidity controller- providing & fixing microprocessor based temp & humidity controller excluding moisture sensors, electrical control panel for fan,cooling pad, pump, mcb, contractor, olr, auto manual switching on/of fswitches ip55 cabinet, electrical cable 1 .5sqmm 4core for fans and pads,sensor cable 4core 0.5square mm etc complete. 43 providing & fixing controller - plc & hmi based control, drip valves control -2 nos,dosing valves control- 3nos ( a-b,c-acid), filling pump, system pump, air pump control, mixing valve control, phase missing prevention, over current prevention control, operation modes: auto -manual-bypass. 44 providing & fixing dosing unit includes dosing channels - 3nos @400lph with flow indicatiors & regulators, dosing valves - 3 nos (a-b,c-acid ), system pump - 30klph@35m head- ss 316 grade, dosing line filters-3nos 45 providing & fixing flow sensor of 3” as per design & drawing etc complete. 46 providing & fixing regenerative air blower-385cfm for 2 stocks mixing as per design & drawing etc complete. 47 providing & fixing solenoid valvesof 2” as per design & drawing etc complete. 48 providing & fixing exhaust fans -1.5hp 3phase- 16 nos4 controls ( each control 4 fans) pad pump - 3hp, 3phase- 1no fogging pump-5hp- 1no acf- 0.5hp- 1phase- 32nos - 1 control (3 phase load distribution) temperature sensor - 1no etc complete. 49 providing & fixing pressure release valves of 2” as per design & drawing etc complete. 50 providing & fixing total galvinsed iron structure of column pipes, profile, zig-zag spring, locking, perlins, tie bar, cross, gutter purlin, hockey , hockey memeber, hockey runner, nagarpatta, galvinsed gutter sheet, l, f brcackets, clamps, bolts , nuts, self drilling screw, spring, sliding pulley, netring, curtain clamps, door cup, handle, fiber door, hole pass. above all incudes, complete structure- erection, fixing etc complete. 51 poviding & fixingpoly film, 50% shade net, 30% side net with 6.5m center height,d rain out, israel make ginegar diffuse 200micron. above all incudes, making foundation, completestructure- erection, fixing etc complete. 52 providing & fixing high-tech irrigation system including inline drip lateral, inside main and sub main pvc pipes, fogger system, sand filter, disc-filter, ventury system with instillation & testing. 3024 sqm etc complete. 53 providing &fixingweed control mat 3000 sq mtr 120 gsm as per design & drawing etc completed. 54 providing &fixingplastic trough20:50:20500 micron 6000 running mtr etc complete. 55 providing & supplying low electrical conductivity coco-peat as instructed etc complete. 56 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 300mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 57 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 600mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 58 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 900mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 59 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 1200mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frameetc complete 60 supply, installation, testing, and commissioning of the electrical trench, with dimensions of 1300mm length, 1300mm width, and 1300mm depth, which includes a cover at every 15-meter interval, and also includes all necessary civil work to complete the electrical trenchetc complete 61 providing and fixing of ‘seamless gloss’ tiles of himalyan acoustics / baux / baswa or equivalent20mm thick with square edge made of gloss base panel (non-magnisite) with wood fibre 1mm width cement composites covered with acoustically transparent absorptive microfibers on the front side pasted on site with sprayable glue and colour as per the choice of the architect/ person in charge with seamless finish. has excellent noise absorption of 0.85 nrc as per iso: 354-1985 and astm 423-90 a, stc of 47 as per astm e90/413 for 25mm, density 400 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60o celcius(140o farenhite) for 15 days= no deterioration. conforms to en 131682001 and are rohs complaint and anti-bacterial test as per jis-z2801-2010.to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results( ceiling absorption nrc 0.85) etccomplete. 62 providing fibrette doodle 20 ceiling tiles of himalyan acoustics / baux / baswa or equivalent made of wood fibre cement composites with an option of colours as per the choice of the architect/ person in charge of size 1200 x 600 mm highly recommend for walls / ceilings. has excellent noise absorption of 1 nrc as per iso: 354-1985 and astm 423-90 a, density 400 kg/ m3, meets stringent fire ratings astmd-876 and fire class -1 and class p-not easily ignitable as per bs-476-part 5,6,7, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60° celsius (140° fahrenheit) for 15 days= no deterioration. tested as per en 131682001 and are rohs complaint. to be installed on g.i studs 600x600mm centre to centre2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life witha backing of himalyan acoustics 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results(ceiling absorption nrc 1 ) etc complete 63 providing and fixing of ‘seamless gloss’ tilesof himalyan acoustics / baux / baswa or equivalent wth 20 mm thick with square edge made of gloss base panel (non-magnisite) with wood fibre 1mm width cement composites covered with acoustically transparent absorptive microfibers on the front side pasted on site with sprayable glue and colour as per the choice of the architect/ person in charge with seamless finish. has excellent noise absorption of 0.85 nrc as per iso: 354-1985 and astm 423-90 a, stc of 47 as per astm e90/413 for 25mm, density 400 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60o celcius(140o farenhite) for 15 days= no deterioration. conforms to en 131682001 and are rohs complaint and anti-bacterial test as per jis-z2801-2010.to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results (ceiling absorption nrc 0.9 )etc complete. 64 providing wooden micro perforated fr grades 600x600 / 600x1200 16mm made of mdf backed with acouscal fleece providing sound absorpon of abs. coeff. 0.92 @125hz as per (equivalent to iso: 354-1985 & astm 423-90).to be installed with hidden aluminium profile conforms to aluminium alloy 6063-t6.temper as per bs:1474-1987. the density per panel is 750-800 kg/m3. these panel are made from acouscal fibreboard with linear perforaons for excellent uniformity. the perpendicular holes areavailable on the panel. wooden micro perforated can be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm acousc wool tested as per fire retardant astmd 635- 1991/insulation and is 15061-2002 for excellent result wall treatment upto 8ft height etc completeof himalyan acoustics / baux / baswa or equivalent etc complete. 65 providing and fixing ‘aphony cortex’ splendortiles made of wood fibre 1mm widthcement composites 25 mm thick (non magnesite bonded) and covered with acoustically transparent woven fabric on the front side, with an option of colours as per the choice of the architect/ person in charge of size 1200x600/ 600x600 mm.providing sound absorption of 1 nrc as per iso:354-1985 and astm 423-90 a, stc of 49 as per astm e90/413 meets the stringent fire ratings astmd- 876 and bs:476, weather resistant as per is 3308 thermal conditivity result 45 w/m2/kas per is:3346-1980. conforms to en 131682001.to be installed with pvc h profile on g.i studs600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of himalyan acoustics. 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 thermal conductivity test , w/mk , as per astm c 518 test result ( sc-6490) -0.03312for excellent results.wall absorption nrc 1 etc complete. 66 providing fibrette doodle 25mm walls himalyan acoustics / baux / baswatiles made of wood fibre cement composites with an option of colours as per the choice of the architect/ person in charge of size 1200 x 600 mm highly recommend for walls / ceilings. has excellent noise absorption of 1 nrc as per iso: 354-1985 and astm 423-90 a, density 400 kg/ m3, meets stringent fire ratings astmd-876 and fire class -1 and class p-not easily ignitable as per bs-476-part 5,6,7, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60° celsius (140° fahrenheit) for 15 days= no deterioration. tested as per en 131682001 and are rohs complaint. to be installed on g.i studs 600x600mm centre to centre2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life witha backing of himalyan acoustics 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results wall absorption nrc 1 etc complete. 67 providing and fixing ‘aphony fibril’ tiles20 mm with himalyan acoustics / baux / baswa or equivalenttaper edge made of compressed wood fibre made with (non-magnesite bonded) inorganic compound with mat blackcolour of size 600x1200/600x600mm. has excellent noise absorption of 0.70 nrc as per iso: 354-1985 and astm 423-90 a, stc of 48 as per astm 90/413 density 650-750 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , tested as per astm c 367-99 to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of himalyan acoustics. 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002for excellent results.make etc complete. 68 providingfloor carpet ofhimalyan acoustics / baux / baswa or equivalent with specification : weight :875 dynamic loading ( bs 4052)nominal thickness ( mm): 4.00color fastness tested as per.is 5641wash ( is 11969)light ( is 0686)flammability test ( is 5641) etc complete. 69 providing and fixing of acoustic door ofhimalyan acoustics / topakustik / baswa or equivalent of 56 mm having an stc rating upto 59.6 @ 100 hz as per iso:140/astm90/413. the door will be filled with high acoustic materials of 2 layers of 8 mm water proof acoustic ply with dampner sheet, 2 layers of 10mm thick absorb wool 300 gsm, sound dampner 12mm 1218x1218 mm made of 10 mm compressed wood cement composites 1250kg/m3 and 2mm dampner sheet 37 stc as per iso 140 (part-iii) - 1995. final finish with teak ply 4mm thick interior and exterior side. door frame will be made of teak wood teak wood/ engineered wood. frame on all four sides or three sides frame and drop seal below will be provided along with the door. high load bearing hinges will be provided along. fr tested as per is:3614 (pt. ii) & bs: 476-(pt.20 & 22). 70 providing and fixing of teak wooden flooring of himalyan acoustics / baux / baswa or equivalent of20mm thickness with polish. teak wooden flooring with tongue and groove system with size 510x90x20mm. termite treated seasoned. to be installed on ply board 16mm.floor polish charges included etc complete. 71 supply & installation of auditorium tip-up chairs:seat to be mounted on center pedestal 75mm x 100mm mounted on ms plate 200mm x 200mm x 6mm thickness. seat & contoured back made in cold injection moulded pu foam of density of 60kg/m3 and 46kg/m3 respectively over metal structure.19 0colored cushion (fabric colour to clients choice) with removable seat cover.seat and backrest frames are made out of metal frame structure black powder coated.upholstered back to with multi angle adjustable mechanism upto 30 degrees inclination.counterweight silent/noiseless tip up seat mechanism, seat shall be able to be removed easily for cleaning and maintenance without the need of any tools. solid armrests laminate finished (wooden appearance) seat number in oval acrylic and row number in metal plate, with provision for wiring to put led illumination. strength & durability of seat to comply to en12727: 2016 for level 4 load test.fire resistance to meet bs5852 & bs 7176warranty 5 years. price inclusive of transportation with all leads and lifts etc, complete. 72 statue- balasaheb thakreproviding statue of 15 ft height in 1st quality fiber material with metal armature (jindal). with internal structure pipe 100mm dia pipe welded together with support pipe in between and arm also with the same pipe of size 1mtr-0.5 mtr the overall height would be 3.5mt from ground. item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. material made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. structural stability certificate will be given. 73 sculpture-1 man sitting providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 74 sculpture 2 man with hammer sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 75 sculpture 3 women standing- sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care 76 sculpture 4 buffalo- sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 77 sculpture-5:- man with calf and calf sculpture -providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 78 sculpture-6:- man standing sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 79 selfie point i love haldi providing & fixing of 2.8m x 2.8 m with height of 2.8m. frp kiosk. made of frp material with dark wood finish. frp dustbin included in the kiosk. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5viscosity aliphatic paint. with long standing life. item is including placing, installation with all fittings, fixture, hardwares , all as per design, drawings & as per instructions from engineer in charge etc. complete on site.
  • View Tender
  • Document
  • Bid Support
7 Civil Work
image image
Central Government/Public Sector
TRN :49023213 |  13 May, 2025
Tender Value : 25.18 Lacs
 Shimla - Himachal Pradesh
Tender for upgradation of general pool residential accommodation at prospect hill, shimla. (sh: miscellaneous repair and renovation work related to upgradation i.e granite cladding, tiling windows, fitting and other misc. works in general pool quarters)
  • View Tender
  • Document
  • Bid Support
8 Educational And Research Institute
image image
Boards / Undertakings / PSU
TRN :48996540 |  13 May, 2025
Tender Value : 1.47 Crore
 Matunga - Maharashtra
Tender for repair, renovation, and reconfiguration of lab 1 at the computer engineering and it engineering department, first floor, vjti, matunga, mumbai.= 1 dismantling of existing partitions, wall paneling, etc., all complete as per site requirements, and stacking the usable materials within building premises as directed by the architect/consultant/ engineer-in- charge, etc. complete. (lead upto 100 meters) 2 removal of cement tiles, existing flooring, wall tiles,marble, polished shahabad flooring, dado with or without bed concrete, including stacking the materials as directed, with all leads, lifts, etc., complete. (lead upto 100 meters) 3 dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. complete. ( lead upto 100 meters) 4 scraping the old paint from the plastered internal surface using a dust-free vacuum paint scraper, followed by coating the entire surface with a mixture of whiting or glue and linseed oil, including the provision of scaffolding, as directed. (the scraping of old paint should be done until the neeru finish of the plaster is achieved.) lead and lift upto 100 meters etc. complete. 5 removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. 6 removing the existing cement plaster of any thickness without causing dust nuisance, stacking the debris up to a distance of 100 meters, cleaning the site, etc. complete. 7 providing and applying an anti-corrosive chemical to exposed reinforcement of r.c.c. members such as beams, columns, and slabs. this includes one coat of alkaline rust converter (feovert, rusticide, or equivalent) after cleaning the surface with a wire brush, followed by two coats of anti-corrosive, epoxy-based, two-component, zinc-rich primer (materemaco p 130 of basf, phenolic ipnet rb, polyalk flxoprime, or equivalent) for rebar protection on exposed reinforcement. additionally, apply a concrete-penetrating corrosive inhibitor (epco kp-100, polalk ep 113, masterseal 1414 of basf, fosroc, or equivalent) over the adjoining concrete surface. etc. complete. 8 providing and applying a bond coat of approved epoxy resin (masterbrace 1414 of basf, epi bond of krishna conchem, or equivalent) before polymer plaster or concrete to ensure a perfect bond between old concrete and new concrete/polymer plaster surfaces. the bond coat should be applied within half an hour after preparation, conforming to astm c881 type 2. this process includes the use of nylon brushes, scaffolding, labor, etc. complete. 9 providing and applying ready-mix polymer-modified cement mortar with an average thickness of 15mm, using polymer in one or more layers, in a proportion of 1:5:15 (polymer, cement, and quartz sand) as per the manufacturers specifications. the surface should be cured after 72 hours of application using wet gunny bags, etc. complete. 10 providing and applying ready-mix polymer-modified cement mortar with an average thickness of 30mm-50mm, using polymer in one or more layers, in a proportion of 1:5:15 (polymer, cement, and quartz sand) as per the manufacturers specifications. the surface should be cured after 72 hours of application using wet gunny bags, etc. complete. 11 providing and applying a 30mm thick self-curing ceramic polymer microconcrete of an approved make, having a compressive strength above m30, non-shrink, and impermeable, as a filling mortar for load-carrying r.c.c. members in two layers on cleaned concrete surfaces, including honeycomb areas (using manual or mechanical means). the mortar shall be prepared by mixing nicosil c80 and fresh 53-grade cement with the required water-cement ratio to achieve the desired consistency. the application and finishing shall be done by manual trowelling. curing shall be carried out after the initial setting time, in accordance with the manufacturers specifications. the work shall be executed in line with the specifications and as directed by the engineer-in-charge. the work must be carried out by a certified applicator, and the work shall be guaranteed for 5 years. the guarantee shall be provided on a rs. 500/- stamp paper. (the bond coat, as per item no. 08 in the boq, is to be applied before the coating.) 12 providing and applying 12mm thick internal/external ready-mix plaster conforming to is: 4031 (part-4) 1988 and is: 383-1970, in a single coat using cement mortar in a proportion of 1:4, with a special type of polymer additive (approximately 0.4%), on all types of surfaces in all positions, including scaffolding and curing. the plaster shall be followed by a smooth finishing coat of gypsum plaster of 6mm thickness, ensuring an even, smooth surface suitable for painting. complete with necessary curing, scaffolding, and all other related works. 13 providing and applying a priming coat over new/old steel and other metal surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter. the surface shall be scoured with wire brushes, fine steel wool, scrapers, and sandpaper, with scaffolding as required, etc. complete. 14 providing and applying priming coat over new wood and wood-based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter, sanding, knotting, scaffolding, etc., complete. (brands such as asian paints, dulux paints, nerolac, berger, royal, or equivalent make.) 15 providing and applying two coats of synthetic enamel paint of approved color to new/old structural steel work and woodwork in buildings, including scaffolding if necessary, cleaning, and preparing the surface (excluding primer coat). etc. complete.(brands such as asian paints, dulux paints, nerolac, berger, royal, or equivalent make.) 16 removing and refixingof doors and windows with frames and stacking the materials as directed, including all leads, lifts, labour, fitting etc., complete. (lead up to 100 meters) 17 providing and laying in pattern 600 mm x 600 mm vitrified tile flooring of 8 to 10 mm thickness and confirming to is 15622-2006 ( group bla) of approved make,quality, shade and pattern for flooring . the tile flooring shall be laid in pattern with 2 mm spacers & tiles fixed in cement mortar of 1:4. the rate shall be including floor chipping to attaining required levels, epoxy grouting of joints using approved matching colour tile grout of epoxy grout, necessary protection of the laid floor, acid wash cleaning for any stains before handover. etc. complete as per the drawing, specification and to complete satisfaction of the engineer. rate to include the wastages as per the pattern indicated in the layouts. brands like kajaria, johnson or similar etc. groove shall be filled with grout of approved shade ( brands like laticrete etc.) as dicectedby the engineer-in-charge. etc. complete. basic rate for tile material- rs. 1440/- per sq.m. 18 providing and fixing skirting, including labor, materials, and all related work, etc., complete. rate for skirting of height up to 150 mm. 19 vinyl flooring for hod cabin:providing and fixing approved color homogeneous flooring, 4mm thick with interlocking system, single-layered flexible spc vinyl flooring (spica by tusker vinyl floorings) in roll form, over the provided i.p.s. or kota stone flooring. the flooring will be fixed using approved adhesive, and all joints will be soldered with pvc rods as per the manufacturer’s specifications. the work will be completed as directed, ensuring proper leveling and cleaning. the roll width will be a minimum of 2.0 meters, and the weight of the pvc flooring will be 90 kg per 30 sqm. as directed and approved by engineer in charge. etc complete. basic rate for vinayl flooring material- rs. 900/- per sq.m. 20 providing and laying vitrified mirror/glossy/matte finish tiles of size 590 mm to 605 mm x 590 mm to 605 mm with a thickness of 8 to 10 mm, conforming to is 15622:2006 (group b1a) from an approved make, shade, and pattern, for dado and skirting in the required positions. the tiles shall be fixed in 1:4 cement mortar, including neat cement float, filling of joints, curing, cleaning, and all related work, etc., complete. basic rate for tile material- rs. 790/- per sq.m. 21 providing second-class burnt brick masonry with conventional/i.s. type bricks in cement mortar 1:6 in the superstructure, including striking joints, raking out joints, watering, scaffolding, and all related work, etc., complete. 22 lowering the debris obtained from breaking and removing cement plaster/burnt brick masonry from the first floor by any means, without causing dust nuisance or damage to the structure. the debris shall be stacked as directed by the engineer-in-charge, including cleaning the site, etc., complete. (lead up to 100 meters.) 23 removing and disposing of debris from the site to a dumping ground outside the vjti premises (in accordance with municipal rules), etc. complete. as directed by the engineer-in-charge. (minimum 6 cu.m debris per trip) 24 providing anti-termite treatment to the wooden frames of doors and windows of the existing building as per i.s. 6313 (part-iii), by drilling 6 mm dia. holes at the four corners on one side and the four corners on the other side, at a downward angle of approximately 45 degrees at the junction of the woodwork and masonry. injecting 150 ml of chlorodane 5% w.c. into each hole and sealing with putty, etc., complete, with a 2-year guarantee on bond paper. 25 providing and applying waterproof melamine polish of the required finish to the woodwork by spray machine, including knotting and preparing an even surface by scraping, applying french polish, scaffolding if required, etc., complete.note: the work is to be executed only with prior approval from the superintending engineer. (brands such as asian paints, mrf melamine or equivalent.) etc. complete. 26 providing and fixing ss t/u/l strip profiles for walls, ceilings, tiles, flooring, main doors, interior decoration, bathrooms, and living rooms, including transportation, wastage, labor, etc., complete.shape: t/u/l profilematerial: ss 304 grade stainless steeldimensions: 8 mm to 12 mmlength: 2440 mm (8 feet), 3048 mm (10 feet)type: t-sectionfinish: polishedposition: interiorcolor options: gold, rose gold, black, silver, champagne, antique hairline, antique copperthickness: 2 mm to 8 mmnote: the shape, pattern, color, and design will be directed by the architect/consultant/or engineer in charge. basic rate for material- rs. 850/- per number. 27 providing and fixing ss t/u/l strip profiles for walls, ceilings, tiles, flooring, main doors, interior decoration, bathrooms, and living rooms, including transportation, wastage, labor, etc., complete.shape: t/u/l profilematerial: ss 304 grade stainless steeldimensions: 16 mm to 32 mmlength: 2440 mm (8 feet), 3048 mm (10 feet)type: t-sectionfinish: polishedposition: interiorcolor options: gold, rose gold, black, silver, champagne, antique hairline, antique copperthickness: 2 mm to 8 mmnote: the shape, pattern, color, and design will be directed by the architect/consultant/or engineer in charge. basic rate for material- rs. 850/- per number. 28 providing and fixing sign boards foor doors:specification for waterproof signage boards (12 x 4 inch)size: 12 inches (l) x 4 inches (h) (with size tolerance is plus or minus 1%)material: high-quality, durable acrylic or pvc boardfinish: glossy or matte finish for clear readabilitywaterproof: weather-resistant, suitable for both indoor and outdoor usedesign: custom text, graphics, or logo engraving/printingmounting: wall-mountable with adhesive backing or screw mountscolors: available in multiple colors with contrast for visibility (e.g., white, black, silver)application: ideal for office cabins, rooms, labs, and other signage needsthis durable, waterproof signboard ensures clear and professional signage in various environments. including wastage, etc. complete. basic rate for material- rs. 460/- per number. 29 providing and fixing of 3d wall panels that can be painted as well.size of each panel: 2 x 2 feet.colour: any color, design, or pattern.features: lightweight, fire-resistant, easily diy, 100% recycled.made from natural bamboo plant fiber, etc., complete. basic rate for material- rs. 450/- per number. 30 providing and fixing wooden decorative fluted wall panels/louvered wall panels:material: high-quality wood (mdf, plywood, or hardwood) with a decorative veneer finish.dimensions: 8 feet x 4-5 inchesthickness: 8 mm - 12 mmdesign: fluted design with vertical or horizontal grooves for a decorative effect.color: multicolor/any colour. (customizable to match interior themes).shape: rectangular panels for seamless installation, etc., complete. basic rate for material- rs. 850/- per number. 31 providing and fixing machine cut mirror polished 16 mm to 20 mm thick telephone black / amba white / cat bary brown / rbi red / ocean brown granite stone partition with rounding the edges etc. complete. one side polishbasic rate for granite material- rs. 2530/- per sq.m. 32 providing and fixing oval-type under-counter wash hand basin of 16-inch x 22-inch size and of special color shade, having telephonic black/colored granite of 180mm thick stone black kadappa framework, including chromium-plated coupling bottle trap. the wash basin should be of cera company or equivalent, model no. 3448, as per the detailed drawing or as directed by the engineer-in-charge, etc., complete. (counter size 1.20m x 0.60m). (brands such as jaquar,kohler or equivalent make.) basic rate for wash basin - rs. 6000/- per number. 33 providing and constructing a granite kitchen platform with the installation of a stainless steel sink (600mm x 450mm) as per the detailed drawing, including vertical polished kadappa stone supports (25 to 30mm thick) on both sides, with a kadappa top (35 to 40mm thick) and a polished granite top (16 to 20mm thick). the platform will feature granite strips at the front and both sides, with two vertical granite supports (15 cm height). the top granite will be 75 cm x 40 cm, including cutting and opening for the sink of the required size in both kadappa and granite. the platform size is 5.00 m x 0.60 m, with a height of 0.75 m, etc. complete with all required finishing. basic rate for ss sink- rs. 6000/- per number. 34 supply and installation of 600x600mm modular metal perforated grid ceiling system (cg-01)the ceiling system shall be supplied and installed as per the specifications provided in the tender document, and in accordance with the directions and approval of the engineer-in-charge. the scope includes complete installation with all necessary materials, components, and finishing to ensure proper execution etc. complete. 35 providing and installation of aluminum frame works for partition with ply on both sides and laminate finish: providing and fixing partition aluminum frame work consist of 25mm x 50mm x 1.2mm thick extruded aluminium box section framework at spacing not exceeding 600mm centre to centre both ways (horizontal and vertical). the framework shall be secured at floor structural ceiling and sill/ lintel level with 25 x 50mm x 1.2mm thick horizontal aluminium section. framework to be secured to floor / walls / columns / ceiling / beams using 75mm metal screws and dowels.acoustic infill: providing & fixing acoustic insulation of approved make to g.i./ aluminum/ ms/ wooden frame partition of 50mm thick rockwool of density 48 kg/m with blanket wrapped in rp tissue suitably affixed to partition framework using where necessary gi binding wire duct tape as indicated in the drawing.outer skin:- providing and fixing 18mm plywood of brands like greenply, century or equivalent. finished with 1 mm thick laminate of approved shade applied on plywood of brands like formice, royal touche or equivalent brand.note: rate is as per aluminum framework with both side ply and laminate. etc. complete. 36 providing and fixing of laminate cladding with ply backing:providing and fixing 12mm bwr plywood (brand: greenply, century, or equivalent), directly fixed to the column. a 1mm thickness laminate of an approved shade, applied on the plywood surface. laminate brands: formica, royal touche, or equivalent. etc complete. 37 providing and installation of glass partition (toughened glass): providing 12mm toughened fixed glass partition including all patch fittings, ensuring smooth and even flush joints between glasses, fixing the same in positions to true line and level, finishing the wall joints with clear silicon sealants, cleaning the surface and ensuring that there are no scratch marks on the glass etc. complete as per drawing and specifications, glass brands should be dorma, ozone or equivalent. 38 providing and installation of glass partition (dgu glass): double-glazed unit glass with air spacer of 6 to 16mm, 95% transparency, etc. complete as per drawing and specifications, dorma or ozone or equivalent. 39 providing and installation of 12mm thick clear toughened glass door with film as required. (d2 - 0.91 x 2.10 m) specification:hardware: door to be complete with hardware to each leaf as follows: hinges: 8 nos. ss ball bearing butt hinges. door closer: concealed door closer with hold open. lock set: dead lock as approved.door handles:900mm ht. 36mm dia d type offset handle on both sides in approved powder coating. door stop: floor mounted door stopper as approved seals: drop down floor seal as approved. security system: na note: all the metal profile sections and hardware finish should match the frame. brands like dorma or ozone or equivalent. etc. complete as per drawing and specifications. 40 providing and installation of d1 - double door two-way sliding motorized door, suitable for door openings up to 1.20 meters with a maximum door weight of 100kg (both leaves). the door offers environmental protection with a working temperature range of -20°c to +50°c and is rainproof. it has a standard opening time of 3-8 seconds, with a remote control operating distance of 100 to 200 feet (depending on line of sight). the opening size is 2.4m x 2.10m, and the glass door size is 1.2m x 2.10m. brands like dorma, ozone, or equivalent, to be installed as per drawing and specifications. etc. complete. 41 providing and installation of d3 - 1.09m x 2.10m (single shutter) 12mm toughened glass door with fixed side panels, including all patch fittings, locking mechanisms, and ensuring smooth, even flush joints between the glass panels. the door is to be fixed in position to true line and level, with wall joints finished using clear silicone sealant. the surface should be cleaned and inspected to ensure there are no scratch marks on the glass. installation to be completed as per drawing and specifications, with brands like dorma, ozone, or equivalent. etc. complete. 42 pop punning: providing and applying of plaster of paris punning(1st quality isi approved pop) over plastered with minimum thickness of 8mm-12mm to existingwall surfaces, ceilings & concrete members etc., to be finished in line and plumb with smooth surface ready to receive paint base. rate to be inclusive of edge protection (gi), fibre mesh for service conduits,hacking wall surfaces for better bonding, cleaning, scrubbing the surface, providing grooves if necessary etc., complete as per architects/consultant/engineer-in-charges approval. brands like gyproc, armstrong, shera or equivalent etc. complete. 43 plastic emulsion paint (leed compliant, low voc): providing and applying plastic emulsion paint finish to walls, partitions, and ceiling surfaces of approved make, color, texture, and shade in two coats, with surface and finish acceptable to the engineer in charge to be achieved within these two coats. any additional coats, if required, shall be at the contractors cost. the work includes preparing existing surfaces by scraping away loose particles, dust, etc., washing and scrubbing, filling cracks with crack filler and binder, cleaning and making the surface dust-free, applying water-based rj london putty as directed, rubbing with sandpaper to smooth the surface, and applying one coat of primer as recommended by the approved paint manufacturer. the work also includes providing necessary scaffolding, cleaning, and protecting the site until handover, as well as masking and protecting all service devices such as switchboards, detectors, etc. the work is to be completed at all heights and leads, as per specifications or as directed by the architect/engineer in charge/consultant. brands like asian paints, berger, or equivalent are acceptable. etc. complete. 44 providing and applying premium decorative wallpaper high-end or custom designs (special finishes, custom patterns)specifications: material: non-woven fabric or vinylroll size: 21 inches wide x 33 feet long (covers 55 sq ft)pattern: various styles (floral, geometric, etc.)finish: matte, gloss, or texturedinstallation: peel & stick or pastefeatures:scratch & water-resistanteasy to clean (wipeable)fade-resistanteco-friendly, voc-freeideal for: living rooms, offices, and accent wallsmaintenance: clean with a damp cloth, no harsh chemicalscustom options: available in various colors and patterns, custom designs upon request. basic rate for wallpaper rs. 600/- per sqm. 45 standing platform (300-450 mm from ffl):construction of a standing platform at a height of 300 mm to 450 mm from the finished floor level (ffl), as per approved dimensions. the platform will be made of 18 mm thick wood (century, greenlam, or equivalent) and finished with wood polish (asian paint wood tec, mrf, or equivalent).materials:frame: mild steel or aluminum, powder-coated for corrosion resistance.surface: high-quality plywood, mdf, or approved materials with a non-slip finish.support: sturdy metal beams or supports for stability.features:height: 300 mm to 450 mm from ffl, as per design.finish: non-slip surface with smooth edges and protective coating.safety: non-slip tread and optional guardrails. etc. complete. 46 stage flooring: supply and installation of interlocking rubber tile flooring at the stage area as per the specifications and drawings provided. the flooring will consist of a 6.0 mm synthetic sport surface, including a =1.50 mm pur protect® treated vinyl surface layer, calendared and grained, supported by a pvc density single closed-cell foam, and reinforced with a fiberglass grid structure. it will feature sanosol treatment for fungistatic and bacteriostatic properties. the flooring will meet the following standards: weight: 3.7 kg/m², impact resistance (en 1517) =8 n/m, abrasion resistance (en iso 5470-1) =350 mg, shock absorption (en14808) =25% (labosport result = 28%), indentation resistance (en 1516) =0.5 mm, ball bounce (en 12235) =90%, vertical deformation (en 14809) =3.5 mm, sliding coefficient (en 13036-4) 80–110, fire (en 13501-1) cfl-s1, anti-viral activity (human coronavirus 229e) – iso 21702 (99.37% after 2 hours), energy return (nf p 90 203) =0.31 m/s, tvoc after 28 days <100 micrograms/m³ (iso 16000-6), floor score®, ce marking, en14904 compliant for multi-sports use, reach compliant, and singapore green label certified. the supply and installation will include making good any damaged surfaces using standard fillers such as birla white cement, cement-based grout, epoxy grout, or mortar, and repainting to match the color.all work will be completed in accordance with the specifications, design, drawings, and the direction of the engineer-in-charge. 47 providing and fixing of overhead storage as per the specifications and drawings provided in the tender document. etc. complete. 48 providing and fixing of surface storageas per the specifications and drawings provided in the tender document. etc. complete. 49 providing and fixing on-site a lab table as per the specifications and drawings provided in the tender document. etc. complete. 50 providing and fixing of office desk/table in faculty lounge as per the specifications and drawings provided in the tender document. etc. complete. 51 providing and fixing of office desk/table in office for hod as per the specifications and drawings provided in the tender document. etc. complete. 52 supply and installation ofhod cabin chair as per the specifications and drawings provided in the tender document. etc. complete. 53 supply and installation of faculty lounge chairs as per the specifications and drawings provided in the tender document. etc. complete. 54 supply and installation of study chairs for labs as per the specifications and drawings provided in the tender document. etc. complete. 55 supply and installation of foldable desklet tables for the seminar hall as per the specifications and drawings provided in the tender document. etc. complete. 56 removingthe exisitng light fixures, fans, wires, cables, swith boards and distribution boards etc. complete. 57 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm (2+1e) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg-pw/sw. (brands for conduits precision/finolex/pressfit. and for cable barnds should be polycab/finolex/havells. etc. complete 58 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 2.5 sq.mm (2+1e) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg-pw/sw. (brands for conduits precision/finolex/pressfit. and for cable barnds should be polycab/finolex/havells. etc. complete 59 supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a / 25a switch combined with indicator lamp and fuse with gang box on wooden board.make /brand (roma/ legrand,/ greatwhite) etc. complete 60 supplying and erecting isi mark modular type 3 pin 6a / 16a multi socket with safety shutter, duly erected on providedplate and box with wiring connectionsetc.complete. brand : roma/gretwhite/legrand) etc. complete 61 supplying and erecting pvc surface modular double mounting plate 3 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) 62 supplying and erecting pvc surface modular double mounting plate 4 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 63 supplying and erecting pvc surface modular double mounting plate 6 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 64 supplying and erecting pvc surface modular double mounting plate 8 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 65 supplying and erecting pvc surface modular double mounting plate 12 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 66 supplying and erecting regular/ standard model ceiling fan of 1400mm with sweep complete erected in position as per specification no. fg-fn/cf brand /orient/polycab/crompton etc. complete 67 supplying and erecting flush-type ceiling fan regulators and electronic step regulators for ceiling fans (600mm, 900mm, 1200mm, and 1400mm sweep), complete with installation on the provided switchboard. make/brand: roma, legrand, or greatwhite. 68 providing and fixing 36 watt 2x2 light fitingsupplying and erecting square shaped crca /die-cast aluminium powder coated housing led panel light (slim edge-lit) 600x600mm suitable for 36 w-40w includingmotion sensor led light with provision for plane front frame with translucent cover fixed to the housing etc.complete .brand philips/havels/wipro etc. complete 69 supplying and erecting 16 to 32 a dpmcb suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 70 supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (24 poles) or tp mcb of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb1 (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 71 providing & erecting 3 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/tripalarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 72 supplying, erecting & commissioning 4 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw-rccb/rccb. (make/ brand: legrand/ schneider/ l&t/ indo asian) 73 supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg-tw etc. complete. cables brands should be polycab/finolex/havells. etc. complete 74 supplying and installing cat-6 cable suitable for networking as per specification no. wg-coc/nc. cables brands should be polycab/finolex/havells. etc. complete. 75 supplying & erecting mains with 2 x 2.5 sq.mm. and earth wire 1.5 sq.mm frlsh pvc copper wire in hms pvc conduit min. 20mm dia. as per specification no: wg-ma/pc.etc complete. brand :polycab/finolex/havels) etc. complete 76 supplying, erecting & terminating xlpe armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.cb-lt/cu(brand: polycab/ finolex/ havells)note - the quantity of wires for looping the required number of air conditioning units has to be calculated by the contractor with respect to the provided architectural working drawing. etc. complete 77 providing & erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) gi sheet of 150 mm width & 20 mm height complete with necessary hardware. cable tray brands should be profab or equivalent. etc. complete 78 supplying and erecting pvc box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification no: wg-ma/box. etc. complete (make/ brand: legrand/ schneider/ l&t) 79 supply & fixing of aluminum box section to be laid on the floor with all excavation, re-cementing & refinishing civil works to make good in line with the existing floor level respective junctionbox to be fabricated in 16 swg gi sheet with cut out as required for terminating the box sections. shall include pvc conduits from jb to work station powerpoints i)150 x 150x 50 mmgijunction box with cover & cut outs etc. complete. (make/ brand: legrand/ schneider/ l&t) 80 supply of a.c split unit (2 ton) :supply of ac split unit as per the specifications, and drawings provided in tender document. make (carrier/ voltas/ bluestar/ samsung) etc. complete 81 supply of 2 ton casatte ac:2 ton inverter casette ac. cooling capacity 3200-8000 watt. offers uniform 360 degree round airflow, with 4 star energy rating. etc. complete. make (carrier/ voltas/ bluestar/ samsung) etc. complete 82 installation of 2 ton ac split unit etc. complete 83 installation of 2 ton ac cassette unit etc. complete 84 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigerant having 22swg thickness and inner dia/size 22mm complete. etc. complete. material selection should be high quality and from reputed brand as directed by engineer in charge. 85 supply & installation electrical communication cable between indoor to outdoor units.cables brands should be polycab/finolex/havells. etc. complete. 86 providing and fixing in position ms frame stand for a.c. units, floor or wall mounted, with vibration isolation pads and frame to be made out of required ms sections strong enough to hold the weight of the ac unit,and should be lockable, including fixing in position using necessary scaffolding, ladder etc, and painting with two or more coats ofapproved enamel paint on a coat of red oxide etc. complete 87 insulated condensate water drain piping constructed out of pvc / hdpe hard pipeswith 6mm thick nitride insulation, fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors fasteners and concealed in brickwork or flooring. etc. complete(make: finolex/ astral/ prince) 88 supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided pc / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/ac system. etc. complete. material selection should be high quality and from reputed brand as directed by engineer in charge. 89 supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 20a, 2 pin plug & earth socket and 20a, 3 pin plug top with 20a/30a single pole mcb having rated short - circuit breaking capacity (icn) 10ka complete erected on angle iron/ gi frame. etc. complete 90 carrying out core cutting of size 3 to 5 dia x 15 length in the c.c./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. etc. complete 91 supply and installation of roller blindsas per the specifications and drawings provided in the tender document. etc. complete. basic cost for blind cloth fabric material rs.900/- per sq.m. 92 carrying out test for ceramic tiles / vitrified tileswater absorption, modulus of rupture (set of 6 tiles) etc. complete. 93 carrying out test for plywood: determination of resistance to dry heat,determination of moisture content,determination of density,thickness of plywood. etc. complete. 94 carrying out test for test for glue adhesion for plywood etc. complete. 95 carrying out test for hollow / solid /aac blocksdensity test. (set of 3 blocks), compressive strength. (set of 3 blocks), water absorption test (set of 3 blocks) etc. complete. 96 providing and fixing 15 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 97 providing and fixing 20 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 98 providing and fixing 25 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 99 providing and fixing on walls/ceiling/floor 32mm dia cpvc pipe with necessary fittings, remaking good the demolished portion, etc., complete. including removing existing pipeline if necessary and conveying and stacking the same in pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 100 providing and fixing 75 mm dia stabilizer pipe/p.v.c. soil vent/waste pipe with necessary fixtures and fittings, such as bends, tees, single junctions, slotted vent, clamps, etc., complete. 101 providing and fixing 100 mm dia stabilizer pipe/p.v.c. soil vent/waste pipe with necessary fixtures and fittings, such as bends, tees, single junctions, slotted vent, clamps, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 102 providing and fixing 10 cm pvc nahani trap with grating, etc., complete. (brands such as astral, finolex, prince or equivalent make.) basic rate for nahani trap is rs. 380/- 103 providing and fixing c.p. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. basic rate for pillar cock is rs. 1250/- per number 104 providing and fixing of exhaust fan 150mm crompton/havels/usha or equivalent etc. complete. basic rate for exhasut fan is rs.1000/- per number 105 providing and fixing stainless steel round napkin hanger for bathroom/towel holder for wash basin/napkin holder/bathroom (chrome) b. heavymaterial stainless steel product dimensions 17l x 5w x 19h centimetersfinish type chromeinstallation type wall-mounted shape round including fitting etc. completed.basic rate for material is rs. 320/- 106 providing and fixing premium front glass shelf - bathroom shelf/kitchen shelves wall mounted with frosted and toughen (tradition 6 x 18) chrome including fitting etc. complete. basic rate for material is rs. 650/- 107 providing and installation of 6 mm thick mirror with 6 mm thick ply backing, as per design. the mirror will be supported by stainless steel finished buttons, etc., complete. (the glass brand should be saint-gobain, borosil, or an equivalent make) basic rate for mirror is rs. 1250/- per sq.m. 108 supply and installation of nsd make smoke detectormodel:66a, certification: ce & ertl etc. complete. 109 supply and installation of nsd make heat detectormodel:66h, certification: ce & ertl etc. complete. 110 supply and installation of response indicator make: nsdmodel: p.s (mini) etc. complete. 111 supply and installation of manual call point (m.s) make nsd 112 supply and installation of 08 zone fire alarm panel make nsd(excel) etc. complete. 113 supply and installation of flasher hooter make nsdmodel no: ms17flash etc. complete. 114 supply and installation of supply & laying 1.0 sq. mm x 2 core copper armored isi cable for alarmsystem. with accessories per meter. brand/make :polycab/finolex/havellls) etc. complete. 115 supply and installation of high quality co2 fire extinguisher (6 kg)type:carbon dioxide (co2) fire extinguisher (for electrical fires and flammable liquids)capacity: 6 kgfire rating: class b (flammable liquids) class c (electrical fires)material: cylinder: steel or aluminum alloyfinish: red powder-coated for durabilityoperating pressure: 55 bardischarge time: approx. 8-10 secondsdischarge range: 3-5 feettemperature range:operating: -10°c to +60°c storage: -30°c to +60°cmounting: includes wall bracket certification: is 15683 (india) / ul/ce certified etc. complete.note: the rates for all fire safety alarm items include the complete supply, installation, commissioning, transportation, freight, and all associated costs. 116 providing architectural/ interior design services : scope of work as below:drawings preparation: 3d views, floor plans, furniture layout, electrical layout, ceiling layout, and partition layout.color scheme & material selection: guidance on colors and material choices for finishes, flooring, and furniture.quality control: ensure standards for structural, civil, electrical, fire safety, furniture work and hvac work.interior planning: optimize lab functionality and aesthetics, including furniture, partition design, and system planning (electrical, hvac, fire safety).modifications: suggest changes to designs based on site conditions and client feedback.coordination & monitoring: ensure project progress and timely completion by working closely with contractors. deputation of interior designer degree/diploma/certificate course having knowledge of autocad and 3d home or equivalent for the full period of the work. designes. monitor on-site execution, ensuring design adherence. taking joint measurements.preparing statements for extra items and excess quantities.compliance & safety: ensure adherence to safety codes and regulations. etc. complete.
  • View Tender
  • Document
  • Bid Support
9 Security Services
image image
Central Government/Public Sector
TRN :48280497 |  17 May, 2025
Tender Value : 4.14 Crore
 Leh - Ladakh
Tender for tender for provision of central mi room at nimu(job no 01/nimu stn/amwp/2023-24); 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 43 2 lump sum price worked out by the contractor for (site clearance, excavation & earth work)as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 44 3 lump sum price worked out by the contractor for (internal electrification)as listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 50 4 lump sum price worked out by the contractor for (internal water supply)as listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 52 5 lump sum price worked out by the contractor for (road, path & hardstanding)as listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 54 6 lump sum price worked out by the contractor for (sewage disposal)as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 55 7 lump sum price worked out by the contractor for (area drainage)as listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 56 8 lump sum price worked out by the contractor for (shed for dg set)as listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 58 9 lump sum price worked out by the contractor for (hot water supply)as listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 59 10 lump sum price worked out by the contractor for (external electrification)as listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 65 11 lump sum price worked out by the contractor for (external water suplay)as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 66 12 sch a part - xii (misc b/r & e/m items) (refer boq)note: this schedule is not pre-priced by mes and the rate indicated as rs 0.00 under col 5 signifies this fact only 13 internal electrifications&f double door three phase prewired distribution board vertical db vtpn 8 way with acrylic door made out of crca sheets 1.6 mm thick,phosphatised powder coated with copper bus bar 200 amps, 415 v,ip 43/ik09, earth stud, din rail, polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingmccb4 pole 63 amp rating repturing capacity 16 ka.(note:- single phase mcbs are to be measured and paid for seperately) 14 s&f led building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240v, ip 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long med grade gi pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith ms clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm pvc insulated 3 core wire complete all as directed and specified by engr-in-charge.note - cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 s&f new wall mounted fan of approved make and type complete all as specified and as directed. 16 s&f tv co-axial socket 1 module, complete all as specified and as directed. 17 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole mcb 20 amps 18 internal water supplys&f single piece vitreous china wash down water closet pan pedestal pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type b-0, as in repairs complete all as spd & directed complete all as specified and directed by engr-in charge.. 19 s&f cp grating including jointing to waste pipe fixed in cement concrete type b-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by engr-in charge. 20 s&f hand shower (health faucet ) with 8mm dia and 1 meter long cp flexible tube and wall hookcomplete all as specified make: cera, jaquar , marc & hindware as per sample and directed by engr -in charge 21 s&f soap dish (s/s), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by engr-in charge. 22 road, path & hard standingm&l for wet mix macadam (wmm) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of morth (ministry of road transport & highways) specification of road and bridge works 2013. manufactured in wmm plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 kn static weight and conslidating required gradient and camber. the finished surface tolerance to be as per table 900-1 of morth specification for road and bridge works 2013 complete all as specified and directed by engr-in-charge. 23 m&l for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to bs 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 m&l for rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m-30 design mix in walls , base slab , baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 m&l for soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonary in cm, rcc cover slab in m25/ sfrc cover, interconnecting pipes of rcc/dwc complete filled with brick bats of size 3m dia and 3 m depth. 26 s&f pvc junction boxes ip 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 nos mcb sp 2.5 amp & 4 way industrial connector including clamp made out of ms flat 30x5mm connection from junction box to street light fitting with three single core pvc insulated, pvc sheathed wire 2.5 sqmm copper & pvc conduit 20 mm dia complete all as specified and directed by engr-in-charge. 27 excavation in trenches by cutting of road crossing/pcc hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by engr-in-charge. 28 s&fht/lt ms cable route indicator 4 dia fixed with two nos of nut, bolt and washers and provision of pcc 1 : 4 : 8 type d-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by engr-in-charge. 29 supply, installation, testing and commissinoning lt panel board suitable for working on 3 phase ,4 wire ,415 volts, ac ,50hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick crca sheetduly powder coated and shall be cpri approved and as approved by ge. the panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, copper bus bar duly covered with heat shrink sleeves colour coaded duly fixed ondmc/smc insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing mccbs shall have extended bus bar links and mounted on 50x50x5mm sizems angle iron frame duly painted including pcc 1:2:4 type b1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of age (i) nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) mccb 400 amps, fp, 36 ka, 415 volts, 50hz - 01 no (i/c)(b) mccb 200 amps, fp, 25 ka, 415 volts, 50hz - 02 no ( chs)(c) mccb 125 amps, fp, 18 ka, 415 volts, 50hz - 04 nos (apfc, tpn db -02, spare )(d) mcb spn 40 amps, 10 ka, 220 volts, 50hz - 03 nos (garage,street light, spare-1)(e) on load chengeover 630 amps 4 pole -01 no (f)digital voltmeter, with vss - 01set(g) digital ammeter, with cts & ass - 01 set(h) led phase indication lamps ryb - 01 set(j)single phase rotary automatic light controller nature switch with voltage range 120-440v,ac,20 amps,ip-65,50hz-01 nos(k) copper bus bar tpn 600 amps rating - 01 set 31 labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and gi tubing in soft/loose soil complete all as specified. 32 m&lfor cutting existing gi pipes and insertion of new tee branches of suitable size to take branch connection of 50mm dia pp-r.note : suitable size of tee branch is deemed to be included in the quoted rate. 33 construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingpcc in foundation of the mixture (1:4:8) d-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) ms steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed ms work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in pcc with two coats of black bituminuos paint andall other relevant work complete . 34 m&l for providing tracer/anti freezing cable required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (central heating system)electric hot water generator : supply, installation, testing and commissioning ofpackage type electric hot water generator constructed out of ms sheet having top open-able cover for easy access and removal of heaters. the hwg shall be suitable for indoor mounting. the generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22g aluminium cladding sheet. the generator shall have electrical capacity of 50 kw. the heater shall be electrical resistance type, copper tube with chromium plating. the generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. the generator shall be suitable for 3 phase, 415+ 10% volts, 50 hz. ac supply. the generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 notes:- (i) allneccassary accessories required for the proper fucntioning of hot water genearator are included in price.(ii) the prices should include lifting, shifting and positioning of units at site.(iii) hot water genearator installation to done as per manufacturer recommendation with all installation requirements i.e foundation, vibration isolator,insulationetc as recommended by manufacturer for the ambient temperature of site. odu installation is included in odu price which includes the civil struture, mechanical structureetc as recommended bymanufacturer.(iv) the contractor/oem will shall submit the hot water generator capacity/burner capacity conforming to relevant is code(v) oem should submit the installation and maintenance schedule/ manual for the boiler. 37 glycol circulation centrifugal pumps: supply, installation, testing & commissioning of pn16 ratedaxial split coupled vertical inline water pump set with ci casing, bronze impeller, ss shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with suitable hp, tefc squirrel cage induction motor with ie3 type class f insulation, motor shall be rating of ip 55, operating on 415 ±10% volts, 3 phase, 50hz ac supply. the external flush line must be used for the purpose of heat dissipation from the mechanical seal.pumps with performance characteristics as given below:the internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 degree celcius to 120 degree celcius. vendor shall be provide antivibration arrangement for pumps . 38 the scope also shall include following below mentioned:(i) electrical by pass starter for pump setas recommended by oem. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) pressure gauges 150 mm dia -03 nos (iv) mounting frame with antivibration pads (in case pumps are inline, anti vibration system shall be as per manufacturers recommendation) (v) rcc/cement concrete foundation for the pump unit. (in case pumps are inline, foundation shall be as per manufacturers recommendation).pump capacity are as under:capacityand pump headnot less than flow 25 usgpm , head 20 mtr (refernce model no. : armstrong : series 4300 - 40-150 - 2p - 1.5 kw) each including the triple duty valve and end suction guide. 39 expansion tank and pressurisation unit:supply, installation, testing and commissioning of insulated pressurised closed water expansion tank suitable for total volume ofglycol - water solution, circuit along with necessary accessories such as along with necessary accessories such as 2 nos pumps (1working +1standby) with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. the tank shall be pre-charged. expansion tank shall be with replaceable heavy duty butyl rubber bladder. the tankconnections should be as per oem recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.the tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. the tank must be constructed in accordance with is-standard 2825-1969 (withlates revision)and rated at pn 16 . the complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.the tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelip55 control panel, pressure transmitter, interconnecting piping & wiring. (tank capacity 500 ltrs). hot glycol - water closed vessel pressurized expansion tank as described above shall be duly insulated with 50 mm thick puf/nitrile rubber insulating material or equivalent u valueinsulating material and cladded with aluminium sheet (20g). electrical by pass starter for pump setas recommended by oem. 40 expansion tank of 500 lts capacity 41 pressurization unit: for pump set -03 nos with control panel and accessories. 42 make up tank: supply, installation, testing and commissioning of factory made make up water tank, rectangular/circular shape, of 4 mm thick ms sheet (is 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of ms and vent with flame arrestor. tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above ffl. service platform shall be provided as per recommendations of oem. the tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. extra high level and extra low level alarm shall be provided. tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.make up water tank as describedabove should beduly insulated with 50 mm thick puf/nitrile rubber insulating material and cladded with aluminium sheet (20g). 43 supply, installation, testing and commissioning ofsteel plate radiator( wall mounted) confirming en- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°c, complete with top grill side cover as standard along with inlet ,outlet valve, air purge valve andwith threaded plug, flow regulator as per oem.the below desired capacity should be calculated at altitude of 3600 mts above sea level. capacity calculation sheet to be provided to engineer in charge. the below mentioned capacity is at inlet temp: 75 degree celcius , outlet temp: 65 degree celcius. referemcwe model series. 44 1.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 45 2.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 46 3.5 kw,type: 33- dkek, length is 1600 mm and height is 600 mm of radiator. 47 5 kw,type: 33- dkek, length is 1600 mm and height is 900 mm of radiator. 48 5 kw,type: 33- dkek, length is 2000 mm and height is 600 mm of radiator 49 m & l for pre-insulated ms pipe,class c havingminimum thicknes of puf insulation as mentioned below and of density 36 kg/cum and 26 gauge al cladding complete suitable for above ground as per sizes shown.the pipes should be insulated with closed cell puf of density 36±2 kg/cum of below mentioned thickness. the pipe should be workable in the temp. range of-50 degree celciusto120 degreec celcius. note:-the pipes size 150mm & below shall be m.s. ‘c’ class as per is : 1239 50 80 mm with 36 mm puf thicknes and 26 gauge al cladding. 51 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 52 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 53 40 mm with 36 mm puf thicknes and 26 gauge al cladding. 54 20 mm with 36 mm puf thicknes and 26 gauge al cladding. 55 buried under ground/exposed to ambient:80 mm with 50 mm puf thicknes and hdpe cladding, 26 gauge al cladding. 56 cabel tray :-supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ground/wall with m.s. suspenders as per is code including bolts & nuts, painting suspenders etc. as required of size 150 mm width x 50 mm depth x 1.6 mm thickness 57 supplying, fixing, testing and commissioning of following diameter valves (pn-16 rating) (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), strainers (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), gauges etc for condenser water circulation as per specifications. insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified. butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets.butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets. 58 80 mm dia butterfly valve 59 65 mm dia butterfly valve 60 50 mm dia butterfly valve 61 supplying, fixing, testing and commissioning of y-strainer (insulated valves) of ductile ci body flanged ends with stainless steel strainer forhot water circulation including insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified of size 50 mm dia y strainer. 62 supplying, fixing, testing and commissioning of non - return valve (insulated valves) with duel plate of ci body ss plates vulcanized nbr seal flanged end & pn 16 pressure rating forhot water circulation includinginsulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as sepcified of size 50 mm dia nrv. 63 supplying, fixing, testing and commissioning of automatic air purge valves forhot water circulation headeras specified of size automtic air purge valve 20 mm dia. 64 supplying, fixing, testing and commissioning of air separator compleate allas specified of size 50 mm dia. 65 supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and ss tubing, socket.range (0-50) / (0-100) as required by engineer in charge. 66 supplying, fixing, testing and commissioning of mercury in glass industrial thermometer in ss-304 casing with 0.5 c least count, range 0-50 c. brass oil filled thermowell of 1/2 size as required by engineer in charge. 67 electrical distribution panel supply, installation, commissioning and testing of factory made, chs plant, indoor type made out of crca sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with ms angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 phase4 wire, 415 volts, 50 hz, ac supply system, floor mounted and grounting the legs of panel in pcc foundation 1:4:8 complete as all directed suitable for and including the following :- 68 incomers(i) bus bar tpn al extensible type main bus bars of minimum of 600 a capacity (as per capacity of corresponding incoming / bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c smc bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50ka .(ii)mccb 400 amps, 415 volt, 36 ka, 4 pole,microprocessor release- 01 no for incoming (extended rotary operating handle, phase spreader links and phase barriers ) make: legrand/schenider/simensoutgoings(i) 3nos- 125a ,25 ka tpnmccb/acbwith microprocessor release (3# hot water generator)(ii) mcb 10 amp,tpn,10ka, c curve - 06, 3 nos for pumps , 2 nos for pumps ,01 nos for glycol transfer pump(iii) led phase indication lamps (01 set) with 2amp back up mcb,breaker on/off indicating light with 2a mcb, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 set (iv) digital ammeter with in built ass,metering c.t.scast resin type, 15va, and accuracy class-1of 800/5a for measuring current in each phase - 01 set.(v) all accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per manufacturers recommendations all as directed by engnr-in-charge.note : contractor will submit the drawing for approval of panel to ge before execution. 69 lt cables : supply & laying/ fixing of following size xlpe insulated and pvc sheathed copper conductor armoured cable/unarmoured as required of 1.1 kv grade complete as require (isi marked) (in ground/in pipe/in duct/on surface/on cable tray) 70 3.5 core x 70 sq.mm. (electric hot water generator) 71 4.0 core x 10 sq.mm. (pump) and (pressurization unit) 72 2 core x 10 sq.mm. (pump) 73 2 core x 6 sq.mm (pressurization unit) 74 earthing complete with copperearth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long gi pipe connected to main controlboard and gi pipe light grade 20mm bore for watering and including funnel, wire mesh, rcc pit cover 50mm thick and pcc chamber pit with pcc 1:2:4 type c2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate no 3 of ssr part-i 2009 complete all as specified & directed by engr-in-charge 75 s&f rubber matting conforming to is-15652-2006 complete as required. of size2m x 1m x 25 mm 76 glycol - water solutionsupplying of ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.note;- (i) the glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. the glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 degree celcius (ii) first charge of glycol is included in the quoted rate. first charge include charge in chs pipe linestorage tank. (glycol 45 % ,water 55 %) 77 for chs 78 supply of gycol for running of plant for 12 months 79 glycol circulating pump: supply, erection, testing and commissioning oftransfer pumps for the capacity of 5 lpm 5 meter head for glycol fluidtransfer with base frame foundation, bolts coupling coupling guard,tefc, (oem design hp for the required flowand head ) andother accessories for proper function of the pump. 80 oxygen gas manhold : supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, nrv and essab make 10x14 regulator complete all as specified and directed by engr in charge . 81 supply , installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by engr in charge . 82 supply , installation , testing and commission automatic control panel with analog display 02 for oxygen complete all as specified and directed by engr in charge. 83 s&f of copper tubing of size 15 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 84 s&f of copper tubing of size 12 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 85 s&f bs type gas outle with probe for oxygen for medical compleate all as specified and directed by engr in charge 86 s&f 1/2 brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by engr in charge. 87 s&f bpc flow meter (0-15 lpm) including humidfire bottle complete all as specified and directed by engr in charge . 88 s&f 3/8 brass ball valveincluding all fittings for complete all as specified and directed by engr in charge. 89 stand by dg set : supply,install, test and commissioning of silent diesel engine generating set 415 volts, 3 phase, 4 wireengine as per is08528 conforming to cpcb norms iv, and alternator as per is08528 of capacity 400 kva at ntp with control panel having meters, sound proof canopy etc with foundation (as per oem design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- ac generator should be suitable for ambient conditions at nimu leh area. 90 (a) alternator : standard design alternator rated at 400 kva (320kw)net output at power factor 0.8, ac, 3 phase 4 wire, 415 v, 50 cycles/second, 1500 rpm self excited, self regulated, screen protected, drip proof ip 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (b)diesel engine : vertical diesel engine of suitable capacity, water cooled, closed circuit as per bs-649 or is-1002 direct injection type turbo charged, electric starting system having rated speed 1500 rpm. the dg set shall be capable for running with 10% over loading for 01 hour in every 12 hours as perbs-5514/bs-649. engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following specifications.(a) fly wheel with housing (i) common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) cooling system (i) radiator with fan & belts & guard, rubber hoses and thermostat. (ii) cooling water pump centrifugal type . 91 (c) governer : electronic governer (d) electric starting system : electric self starter , 24 volts dc(12 volt, 150 ah battery 2 nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2x12 volt 150 ah capacity. (e) generator monitoring panel : comprising of following :- (i) microprocessor based genset controller for metering, monitoring, governing and protection. (ii) engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) accessories:avm pads built or separately mounted to manufacturer base frames. (g) coupling arrangements: fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) exhaust system : should have equipped with emission control device as per latest govt norms. silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) fuel tank: daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (c)acoustic enclosure : all as per cpcb norms iv and oem of dg sets design.(d)amf panel : supply, install, testing and commissioning of amf panel outdoor type, cubical body,dust and vermin proofmade up of crca sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to ip 45 with front and rear opening with louvers andmounted on floor with pcc pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) microprocessor based panel -01 no(ii) power contactor heavy duty suitable for generator and mains (iii) over load relay for genset (iv) suitable rating isolating switch mccb for both dg & main supply.(v) multi functioning meter to indicate voltage, current, frequency, p f, kw & kwh etc (vi) emergency stop push button.(vii)set of indicaters : - (a)low lube oil pressure (b) dg set over load(viii) push button to start, stop (ix) mode selector switch i.e auto/manual/test/ off.(x) set of instrument fuse (xi)set of aluminium bus bar of 600 amps capacity 3 ph, 4 wire system (xii) automatic battery charging unit with dc voltmeter, ammeter and selector switch for trickle/ boost charging.(xiii) by pass arrangement of main supply when amf circuit fail due to any fault with provision of suitable rating change overs and switches. 93 the following items are deemed to be included in the rate quoted for all dg sets:- (i) dhpp for testing purpose shall be supplied by the contractor without any extra cost to department. (ii)the contractor shall arrange for artificial load (water load/electrical load) for testing for final testing of dg set at site and the cost is deemed to be including in above offer. (iii) testing of sound level should carried out at the site in presence of engineer-in-charge(iv) one set of latest spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) all civil works including foundation for dgset as per manufacturers drawing/ specification, foundation for amf panel shall deemed to be included in the quoted rate.(vi) the rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
  • View Tender
  • Document
  • Bid Support
10 Power Plant
image image
corporations/Associations/Others
TRN :34439728 |  14 May, 2025
Tender Value : 0
 Namakkal - Tamil Nadu
Tender for improvements works to the rest room in the sankari 110kv grid ss
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : cladding work
  • Feeder Bay Tenders ,
  • Cattle Trough Tenders ,
  • Kennel Repair Tenders ,
  • Concrete Surface Tenders ,
  • Masonary Work Tenders ,
  • Dispensary Repair Tenders ,
  • Sentry Post Tenders ,
  • Steel Construction Tenders ,
  • Civil Work Tenders ,
  • Brick Lining Tenders

Get cladding work Tender Alert...

674299

Related Searched Keywords : cladding work

  • Earth Excavation Tenders From Maharashtra
  • Floor Tiling Work Tenders From Delhi
  • Tubewell Tenders From West-Bengal
  • Drainage System Tenders From -Tamil-Nadu
  • Ceiling Works Tenders From Andhra-Pradesh
  • Ceiling Tenders From Gujarat
  • Interlocking Tiles Work Tenders From Karnataka
  • Land Development Work Tenders From Uttar-Pradesh
  • Water Proof Tenders From Rajasthan
  • Granite Work Tenders From Madhya-Pradesh

Read More


Tender Document

046619

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Grouting Work Tenders
  • Civil Engineering Service Tenders
  • Railway Over Bridge Tenders
  • Rcc Roofing Tenders
  • Drainage System Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App