Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Digital Vibration Meter
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of digital-vibration-meter Tenders

List of latest digital-vibration-meter Tenders in Indian Tenders. Click on any digital-vibration-meter Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for digital-vibration-meter Tenders.

Advance Search
  • All-Tenders (4)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
2 Construction
image image
State Government
TRN :49022392 |  13 May, 2025
Tender Value : 31.44 Lacs
 Gangapur - Maharashtra
Tender for providing electrical installation in, premises street light, water pump and fire extinguisher for the newly constructed zilla parishad primary health center (p .h .c)main building (g.f+f.f) [under scheme d.p.c. (general) year 2022-23, 34512595 construction expantion & m/ce & repairs of p.h.c/ phsc) at village,lasur stationtq. gangapurdist. chhatrapati sambhajinagar.= 1 supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit 2 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 3 supplying anderectingpvctrunking (pvc casing-n-capping)ofsize20 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 4 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 5 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize40 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 6 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 7 supplying and erecting green earth wire 1x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 8 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 9 supplying and erecting green earth wire 1x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 10 supplying and erecting mains with 4x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 11 supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 12 supplying and erecting mains with 4x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 13 supplying and erecting green earth wire 1x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 14 supplying and erecting mains with 4x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 15 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 16 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 17 supplying and erectingceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. 18 supplying and erectingmodular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 19 supplying and erectingmodular type switch 16aduly erected on provided plate and box with wiring connections complete. 20 supplying and erectingmodular type bell-push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. 21 supplying and erectingmodular type 3 pin 6amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. 22 supplying and erectingmodular type 3 pin 6 / 16amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 23 supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. 25 supplying and erecting pvc surface modular switch box with double mounting plate for 2module duly erected. 26 supplying and erecting pvc surface modular switch box with double mounting plate for 3module duly erected. 27 supplying and erecting pvc surface modular switch box with double mounting plate for 6module duly erected. 28 supplying and erecting pvc surface modular switch box with double mounting plate for 12module duly erected. 29 supplying and erecting 16 / 20 / 25 a starter (modular range) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 30 point wiring for light/bell/exhaust fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 31 point wiring for ceiling fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 32 wiring for plug on board withswitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no: wg-pw/cw 33 supplying and erectingled square / circular max. 11 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 34 supplying and erectingled square / circular max. 14 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 35 supplying and erectingled square / circular max. 18 w down lighter/ panel light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 36 supplying and erectingledpanel light(600mm x 600mm) max. 30 whaving crca powder coated housing,polystyrene diffuser havingsystem lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 37 supplying and erecting anodized aluminium corridor / passage / mirror light led fitting (2 feet) max. 12wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%,thd<10%,p.f. >0.95, operating range of200-270v, surge protection of 2 kv, life class of 50,000 hrs. at l70b50, including driver with end caps on provided pvc block / wooden board with 3 years warranty. 38 supplying & erecting inverter led batten 10w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 39 supplying & erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 40 supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. 41 supplying and erecting integrated led street light fitting26 to 30w ip65 & ik08 class having single piece pressure die-cast aluminium housing ,having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 42 supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg-odf/fls2. 43 supplying and erecting integratedled street light fitting 100-110w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 44 supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg-odf/ptl 45 supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg-bkt/wb 46 supplying & erecting 3w, 230v integral type led lamp suitable for b-22 / e-27 base.(night lamp) 47 supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg-fn/cf 48 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. 49 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. 50 supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg-fn/exf 51 supplying and erectingenergy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg-fn/cf 52 supplying and erecting fan hook of 10 mm. m.s. round bar grouted in rcc slab with making the site as original. 53 providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 54 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no fg-fas/msc 55 supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof abs plastic body, high grade ss inner tank & 3kw heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermalcut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250v, 50hz, a.c. supply with inlet and outlet, with 3 core pvc flexible copper wire leads duly tested and marking sr. no. and date of erection complete. 56 supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). 57 supplying & erecting 15mm brass non return valve for inlet pipe of storage water heater. 58 providing fiber reinforced pvc flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete. 59 supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 60 supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 61 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigerant having 22swg thickness and inner dia/size 12mm complete. 62 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigeranthaving 22swg thickness and inner dia/size 16mm complete. 63 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. ap-wcr/wc 64 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. ap-wcr/wc 65 supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) 66 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine waveinverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology completeas per specification no.ap-inv 67 supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 68 supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270v and output voltage 200-250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. 69 supplying and erecting switch disconnector fuse (sdf) switch 415v, 100a,open execution, four poleac23 a rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to is/iec 60947-3 part-1/3hrc - din type fuse, insulation voltage 1000 vfor enclosing in panel with rotary handle for on / off operation (without hrc fuse) 70 supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a,powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / cc foundation. 71 supplying, erecting & marking spmcb 0.5a to 5a, c-series with rated short - circuit breaking capacity (icn) 10kain provided distribution board as per specification no. sw-swr/mcb 72 supplying, erecting & marking spmcb 6a to 32a, c-serieswith rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 73 supplying, erecting & marking spmcb 6a to 32a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 74 supplying, erecting & marking dpmcb 6 a to 32 a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 75 supplying, erecting & marking tpmcb 6a to 32a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 76 supplying, erecting & marking tpmcb 40a to 63a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 77 supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40awith required wiring connections and lugs etc. in provided distribution board. 78 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board. 79 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63ain provided distribution board. 80 supplying&erectingtriplepole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flushmounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb 81 supplyingand erecting single pole and neutral distributionboard (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw-swr/mcbdb 82 supplying & erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb /tp mcb/fp mcb/rccb/rcbo complete erected on angle iron/gi frame. 83 supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb1 84 providing & erecting 4 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb (rate of 3 pole mccb +20% for 4 pole mccb= 5309x20%+5309=6370.80) 85 supplying and erecting cupboard for enclosing switchgears orforany other purposemadefromselected marine plywood planks 19 mm thick duly varnished/ painted from inside and from outside with brass hinges and locking arrangement with suitable lock with keys in duplicate. cupboard shall be duly grouted with suitable size of iron work in wall at the bottom. (size of cupboard 0.5x1x2+0.5x1x2+1x1x2= 4 sq.mtrs.) 86 supplyinganderectingiron, sheet metal work consisting of crcasheets, varioussectionsofiron,plates, chequeredplates,rods,bars,mspipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 50x50x4mm angle @ 3.4 kgs x 6 mtrs.= 20.40 kgs i,e 20 kgs. 87 supplying and erecting 525 v 3 phase, 50 hz., mpp type capacitor having minimum overcurrent capacity of 1.8 in,peak inrush current capacity 300 inand minimum life 150000 hourskvarbank of all polypropylenecondensers (app)withthestandard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kvarunitsofp.f. correctionforoperationon 3 phase 50 hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and providedwithterminalcoverbox completeerected onprovidediron bracketoronfloordulytestedby licensee.( original p.f=0.8 desired p.f = 0.95 for this multiplying factor is 0.421. so 0.421 x 46.440 = 19.55 i.e 10 kvar x 2= 20 kvar) 88 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 89 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al (double run) 90 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 91 supplying & erecting g.i. pipe‘a’ class 50 mmdia.erectedfor enclosingxlpearmouredcable on wall/poleas per specification no. cb-ce 92 supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 93 supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mmoutside dia. double wall corrugatedpipes (dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 94 supplying & erectingcast iron cable indicatorplate buried along with route of cable for pvc / xlpe armoured cableas per specification no. cb-cip 95 supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thickcomplete on pole/wallas per specification no. cb-sb 96 providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh-pl/opl 97 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 98 providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 99 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. ea-ep 100 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. ea-ep 101 providingpipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea-ep 102 supplying and erecting gi strip of required size used for earthing on wall and/or any other purpose with necessary gi clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsas per specification no. ea-ep.(25x3mm strip. perpole 1.5 mtrs. so for 13 poles 13nos.x1.5mtrs.= 19.5 mtrs. weight of strip @0.590kgs/mtr. so 19.50mtrs.x0.590kgs.=11.51 kgs.) 103 supplying and erecting minimum three & above star rated 1 phase, 230 v, 50 hz, submersible pump set of 1.5 kw/2hp suitable for erection on open well, pump having delivery head from 29to 7 m and discharge from 30 to 600 litres. . per minute& pipe of suction 50 mm/delivery 50 mm diameter erected with necessary h type clamps as per specification no. wp-osp 104 supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. 105 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c. submersible/centrifugal pump set up to 3 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 106 supplying & erecting carbon dioxide (co2) fire extinguisher of 4.5 kg. capacity cartridge type conform to is 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. m. s. flat with nut & bolts routed in wall complete. 107 making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (02x02x02 foundation for main control panel stand and for street light control panel 0.2x0.2x0.2mtr.=0.16 cu.mtrs.) 108 makingm- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). 109 supplying and erecting isi mark gi pipe 50 mm dia.‘b’ class at position with accessories complete as per specification no. cw-plb/gp. 110 supplying and erecting high density polythene pipe isi mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete. 111 supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. 112 supplying and erecting non return valve 50 mm dia in position made of gun metal complete. 113 lum sump provision towards service connection charges1 no.3 phase @ rs. 55000/-/per total rs.55,000/-
  • View Tender
  • Document
  • Bid Support
3 Housing Urban And Rular Development
image image
Local Bodies
TRN :48606691 |  15 May, 2025
Tender Value : 56.65 Crore
 Prayagraj - Uttar Pradesh
Tender for tender for kareli - nurulla road to askari market road block c and block d housing scheme and nurulla road from mahavir chauraha to karamat ki chowki near sasur khedari river and also till the connecting road - clearing grass and removal of rubbish upto a distance of 30 m outside the periphery of the area as per technical specification clause 201. 3 dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 60 metres as per instructions of e-i-c. (by mechanical means). 4 i) cement concrete 5 ii) reinforced cement concrete/ r.b. 6 dismantling of flexible pavements and disposal of dismantled material up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per technical specification clause 202. bituminous / granular courses (by mechanical means) 7 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 8 removing all type of hume pipes and stacking within a lead of 1000 metres including t&p, earthwork and dismantling of masonry works. 9 (i) up to 600 mm dia 10 removal of telephone / electric poles / street light / lamp post including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately 11 disposal of moorum/building rubbish malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of engineer-in-charge. note- item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 12 dewatering using 10hp to 70hp diesel engine pump set including hire charges, cost of diesel, engine oil, pump operator, labor charges, conveyance of pump set and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (hire charges for diesel pump set for 10 hp) 13 [b] bill no. 2 - earthworks 14 excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and leading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location within all lifts and lead upto 1000m 15 removal of unserviceable soil including excavation loading and disposal but excluding replacement by suitable soil which shall be paid separately as per clause 305 16 i) lead upto 1000 m 17 ii) lead upto 8000 m 18 earth work in excavation of foundation of structures as per drawing and technical specification, including setting out construction of shoring and bracing, removal of stumps and other deleterious matter dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for road work. 19 mechanical means (depth upto 1.5 m) 20 i) excavation 21 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 22 [c] bill no. 3 - development of carriageway 23 stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with irc-sp-72-2015 , irc-37-2012 & 2018 and irc sp 89 (part ii) 2018. cementitious additive @ rate of minimum 5 - 7% and ccs/cs additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. the additive spreader shall have variable working width sufficient to cover whole pavement lane. the in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. the resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per irc 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. the entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. the tandem roller be followed by pneumatic tyre roller. the minimum unconfined compressive strength (ucs) of stabilized sub base/ base should be 4.5 to 7 mpa after 7 / 28 days of curing as per irc-sp- 72-2015 , irc-37-2012 & 2018 . also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the gradation mixes and materials should be as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the train of equipments to be used are binder spreader- water tanker- additive truck- recycler- padfoot roller (20 tonne) + single drum compactor- grader- tandom roller- pneumatic tyreroller (20 tonne) 24 sami layerproviding and laying stress absorbing membrane interlayer (sami)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of claues 703-3, laid over a tack coat of paving grade bitumen 80- 100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement surface. 25 providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (tack coat on bituminous surfaces ) 26 providing and laying 40mmthickbitumencarpete(b.c.) with 100-120 tph hot mix plant producing and average output of 75 tonege par hour using crushed aggregates of specified grading premixed with bitumen binder(vg-30) @ 5.40% of mix as per most specification clause. etc all comp of work. 27 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from aggregat aggregate natural sources, portland pozzolana/ordinary portland/portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall. be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 28 m.s. (tor steel or plain) in plain work such as rcc or rb work including binding for proper shape and including supply of steel and its wastage bend, hooks and authorized overlapping shall be measured and including cost of binding wire. excluding gst (sor-504). 29 [d] bill no. 4 - pedestrian infrastructure (footpath) 30 sand filling in foundation trenches as per drawing & technical specification and as per direction of engineer-in-charge. (including beneath all paver blocks, cobble areas for levelling purpose, etc.) 31 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. (pcc below all paving area, kerb channel, road edge kerb, table top, property edge beam) 32 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 33 i) for grading-i material 34 plain/reinforced cement concrete in open foundation complete as per drawing and technical specifications, pcc grade m30using batching plant transit mixer & manual placing(80 mm thickness) r & manual placingand giving broom finish. (pcc with broom finish thickness 80 mm) 35 providing and laying 75mm thick m-30 grade batch mix cement concrete and applying stamping finish to the top surface of freshly laid plain/ reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the engineer-in-charge. the process shall include the following:-the concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. the approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. the approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. these stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the hole surface to be stamped is completed within the time while concrete is in plastic stage of setting.after stamping, the curing shall be done as per manufactures specifications. after initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per theequirement. the surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.the construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (pu) polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (cost of concrete for flooring is not included in this item which shall be paid separately.) 36 80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 37 supply and fixing of tactile indicators made from ss-304 grade stainless steel. warning tactile indicator shall be installed on the walking surface in a raised grid pattern of dots or stud. minimum 36 studs to be placed in 300x300 mm area. dimensions - 35mm outer dia x25mm inner dia, stem dia 8mmx12mm, weight - 28grm.all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property, all complete as per direction of engineer-in-charge. 38 supply & fixing of tactile indicators made from ss-304 grade stainless steel. directorial tactile indicator shall be installed on walking surface, consisting of a series of raised bar/strip. min 4 bars/strip to be placed in direction perpendicular to distance of travel in 300x300 mm area. dimensions-280mm l x 35mm w x 4.5mm, stem dia 8mmx12mm, weight - 250grm all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property., all complete as per direction of engineer-in-charge. 39 providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to is : 15622 of approved make in all colors and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer-in-charge 40 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (dsr-11.20) 41 providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of engineer-in-charge. (saucer drain along the road edge, curved kerbs at property entry/exit, curved kerbs at side roads) 42 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 43 cc grade m20 using batching plant transit mixer & manual placing all complete as per direction of e-i-c. 44 [e] bill no. 5 -parking 45 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 46 i) for grading-i material 47 supplying and filling in plinth with sand under floors/in trenches, including watering, ramming, consolidating and dressing all complete with material (from source to site), labor and t&p etc. required for proper completion of the work. (including royalty). 48 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days and giving broom finish. (pcc) 49 providing and laying factory made chamfered edge cement concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using pu mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of engineer-in-charge.80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 50 [f] bill no. 6 -cycle track 51 nil 52 [g] bill no. 7 - traffic signs, markings and other road appurtenances 53 providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow ms tube posts/horizontal members/bracings covered with 1.63mm thick ms sheet. the sheet shall be fixed with 30x5mm ms flat by suitable welding/riveting. the panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. ms channel islc 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long ms angle 40x40x6mm bracing. suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. the work shall be executed as per drawing/direction of engineer-in-charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the engineer-in-charge. the barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of engineer[1]in-charge.(note :- one time payment shall be made for providing barricading from start of work till completion of work i/c shifting. the barricading provided shall remain to be the property of the contractor on completion of the work). 54 reflective raised pavement markers (cat eye/ road stud) supply and fixing of raised pavement marker with made of plastic body of rpm/ road stud shall be moulded from asa (acrylic styrene acrylonitrile) or hips (high-impact polystyrene) or acrylonitrile butadiene styrene (abs) or any other suitable material approved by the engineer. the marker shall support a load of 13,635 kg tested in accordance with astm d4260. the reflective panels shall consist, of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face. lenses shall be moulded of methyl methacrylate conforming to astm d788 of equivalent. the slop or retro-reflecting surface shall preferably ba 5+/.5 degree lo base and the area of each retro -reflecting surface shall not be less than 13.00 $q.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & width shall not exceed 130 mm the base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. the contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the engineer . in addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. in case the markers are, displaced , damaged . get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the engineer , at his own cost. the rate shall include all materials, labor, t&p, transportation, installation and incidentals all complete as per direction of the engineer-in-charge, 55 rpm with shank 56 solar power road marker the solar studs shall be made of aluminum alloy and polycarbonate material which shall be absolutely weather resistant and strong enough to support to load of 13,635 kg tested in accordance with astm d4280. its color may be white, red, yellow, green or blue or combination as directed by the engineer. its water resistance shall meet the requirements of ip 65 in accordance with is: 12063:1987 category 2 for the protection against water ingress. the dimensions of solar studs shall not be less than 100 mm * 100 mm * 10 mm. it shall have super bright leds so as the provide long visibility from a distance of more than 800 m. its flashing rate shall not be less than 1 hz. its should be able to give the prescribed performance in the temperature range of -40 degree c to +55 degree c. its life shall be not less than 3 years. the rate shall include all material, labor, equipments, fabrication, transportation erection, installation and incidentals all complete as per direction of the engineer-in-charge 57 r.cc work (1:1.5:3) (m-20) with cement course sand &20mm the stone grit including all complete cement concrete with cement sand &20mm gauge stone grit with the proportion of (1:1.5:3)including all complete the work (morth ra-12.8 c, case-ii) 58 m.s. or iron work plain or tor for rcc work including cutting, bending, rivetting or welding etc. where necessary. excluding gst (s.i.no-504) 59 painting two coats on new concrete surfaces - painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 60 m.s. or iron work of heavy sizes section such as trusses, built up gates, record racks, roof work, gates etc. including rivetting or welding where necessary. excluding gst (s.i.no-503) 61 painting of m.s. grill with enamul paint etc all complete work. (s.i. 15.15 new item no.) 62 providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 63 providing and fixing of retro- reflectorized cautionary, mandatory and informatory sign as per irc :67 made of high intensity grade sheeting type-ivvide clause 801.3, 2mm thick aluminum sheeting, 1.5 mm thick supported on mild steel angle iron post 75mm* 75mm *6mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45cm* 45cm*60 cm, 60 cm below ground level as per the approved drawing. the retroreflective sheeting shall be tested for a certificate of having the sheeting coefficient of retro reflection, daytime, color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoors weathering and its having passed these tests shall be obtained from international/ government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should be also obtained from indian condition within 3 years of launching ofproduct by the manufacturing abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirement from a reputed laboratory in india can be accepted provisionally. in such a situation , the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per irc 67:2012 . legends, letters, numerals, and borders etc. should be as per mort&h specification 801.3.7. proof of the same in form of government reports shall be uploaded while quoting tender. 64 90 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 65 60 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 66 60 cm circular with diffinitation plate size (20cm x 60 cm) 67 80mm x 60mm rectangularwith diffinitation plate size (20cm x 60 cm) 68 60 mm x 45 mm rectangularwith diffinitationplate size (20cm x 60 cm) 69 60cm x 60cm square with diffinitation plate size (20cm x 60 cm) 70 90 cm high octagon 71 direction and place identification signs up to 0.90 sqm size board providing and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/ client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area not exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60cm., below ground level as per approved drawing, complete. 72 direction and place identification signs with size more than 0.90 sqm size boardproviding and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility. liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing, complete. 73 providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per irc :67 74 brick masonry work in cement mortar 1:4 (1cement: 4 coarse sand) in foundation complete with cement concrete bricks procured from c&d waste recycling plant baswar excluding pointing and plastering, as per drawing and technical specifications. 75 struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 finerness modulus.sor 2022 si no574 76 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 sand)and as per direction of engineer in charge. 77 finishing walls with ready mixed premium acrylic emulsion paint (company depot tinted) having volatile organic compound (voc)less than 50 gm/liter and uv resistance as per is 15489:2004, alkali, & fungal resistance, dirt resistance exterior paint of required shade with silicon additive(for painting wall, street furniture) new work (two or more coats applied @1.43 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm) 78 supplying and fixing of cast iron antique style bench having weight of sides not less than 72 kg (36 kg each) fitted with fibre rectangle strip (should not be less than 50 mm x 25 mm and 1.6mm thick. length of bench should not be less than 6 ft (end to end of castiron support). 79 [h] bill no. 8 - utility and street light cabling 80 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(pcc below pipe of storm water, sewer, water, inspection chamber for storm water, telecom chamber, power chamber and sewer) 81 providing and laying non pressure np-3 class (medium duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (storm water, sewer) 82 600 mm dia rcc pipes 83 providing of 7- way 40mm multi ducts with solid permanently solidly lubricated silicone in inner layer for ict fiber cables conforming to astm f 2160, astm d 2444 and /or equivalent indian standard. external sheathshall be in orange colorand shall be free from visual defects like blisters, shrink holes,flaking, scratches, groove lines & surface roughness. the color of the 7 nos. plb hdpe ducts shall be green, blue, yellow, brown, violet, grey , red for differentiation. outer sheet thicknessshall be 1.2mm +/-0.2mm. the inner surface of the multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. wall thickness(mm) of each of the ducts excluding rib height shall be 2.9mm +/- 0.3mm. iso requirements- iso 9001, 14001, 18001, complete as per specifications and directions of engineer-in-charge. (7 way multi utility duct for ofc) 84 supply of hdpe pipe of size 110mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.110mm dia hdpe pipe pn-6 class pe-100 85 supply of hdpe pipe of size 63mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.63mm dia hdpe pipe pn-6 class pe-100 86 rcc grade m20 using batching plant transit mixer & manual placing ( side wall, bottom slab for all inspection chamber i.e. storm water, telecom, power, sewer, water) 87 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class b125 having minimum load capacity 125 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. 88 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class d400 having minimum load capacity 400 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. (storm water) 89 supply and fixing gully grates red 048 grh – 300* 750mm d.i. gully grate & frame in d400 load class , as per bs en 124 black bitumen paint, all complete as per direction of engineer-in-charge. 90 constructing rcc rectangular type manholewith a floating coat of neat cement, foundation concrete 1:6:12mix (1 cement : 6 coarse sand : 12 graded brick bats 40 mm nominal size), and making necessary channel in cement concrete of m-25 grade finished with a floating coat of neat cement, all complete as per standard design and instruction of e-i-c. 91 restoration of water pipeline in case of damage 92 [i] bill no. 9 - horticulture / landscaping works 93 trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 94 supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 95 supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 96 mixing earth and manure in specified proportion or as directed. 97 rough dressing the trenched ground including breaking the clods. 98 fine dressing the ground 99 spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 100 uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 101 providing & laying selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 102 preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of officer-in-charge. 103 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 104 providing and stacking of nauclea cadamba (kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 105 providing and stacking of nyctanthes arbor-tristis (hasingar) of ht. 90-105 cm in earthen pots of size 20 cm as per direction of the officer-in-charge. 106 providing and stacking of terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 107 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 108 providing and stacking of plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 109 providing and stacking of ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 110 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 111 providing and stacking of duranta golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge.. 112 providing and stacking of tradescantia zebrina having in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 113 providing and stacking of wedelia trilobata,full of leaves in 15 cm size ofpoly bags & as per direction of the officer-in-charge. 114 providing and stacking of asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of earthen pot / plastic pot & as per direction of the officer-in-charge.. 115 providing and stacking of ophiopogon jaburan ( variegated ), full of variegated leaves in earthen pot/plastic pot of size 20 cm. as per direction of the officer-in-charge. 116 providing and displaying of croton petra bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 117 providing and fixing ms iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 nos (25 x 6 mm) and 8 nos (25 x 3 mm) vertical ms riveted to 3 nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of priming, complete in all respects. 118 street light works (excluding gst) 119 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 mtr length) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p complete in all respect 120 supply and fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. confirming to ip 66 protection complete in all respect. cat: aaa 121 supply and laying of 16 sq.mm. 4 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 122 supplying and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 123 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 124 making connection of each street light by s/l 1.5 sqmm frlsh copper wire complete as per direction of engineer in charge. 125 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with double arm bracket (1 mtr length each ) on rcc foundationincluding the cost of foundation, foundation bolts, excavation & back filling and required t&p completee in all respect. 126 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 127 supply and fixing for automatic street light cubical control juction box painted with anti-corrosive alkali and acid proof pait consisting of 6 amps mcb (b - curve) complete in all respect 128 supply and fixing of 16 sq.mm plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 129 supply and fixing of 40 amp. capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 130 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. 131 supply/ erection of surface mounted decorative pole 4500 mm long having base plate 300x300x12 mm with the bottom dia 139 mm upto 1 mtr long with the thickness of 3.6 mm and the top dia is 76 mm upto 3.5 mtr. log. decorative pole made out of galvanized iron tube with cast aluminium embellishments. the poles are painted with polyturetnane paint. the pole have service window at the bottom on the pole for housing the mcb and terminal strips and as per attached drawings. 132 s/f of single arm decorative bracket 100 mm long made of cast iron/ aluminium embellishments painted with polyturetnane paint. 133 supply of led decorative drop down light made of aluminium housing fitted with polycarbonate diffuser having 500 mm dia with 70 w. 134 supplyandlayingof aluminiumconductorpvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 135 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 40 a tpn 136 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 16 sq. mm 137 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 138 supply and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 139 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 140 part - b utility shifting (including gst) 141 converstion of lt overhead line by underground lt line 142 lt xlpe insulated cable of size 3.5x400 sqmm. 143 lt xlpe insulated cable of size 3.5x240 sqmm. 144 lt xlpe insulated cable of size 3.5x150 sqmm. 145 lt xlpe insulated cable of size 3.5x70 sqmm. 146 9 mtr long stp 147 hdpe pipe 140mm dia peb0, pn-6 148 hdpe pipe 120 mm dia peb0, pn-6 149 hdpe pipe 75 mm dia p880, pn-6 150 aluminium crimping lugs 400sqmm 151 aluminium crimping lugs 240sqmm 152 aluminium crimping lugs 150sqmm 153 aluminium crimping lugs 70sqmm 154 6 swg g.l. wire for earthing along cables. 155 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x400 sqmm. lt cable 156 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x240 sqmm. lt cable 157 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x150 sqmm. lt cable 158 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x70 sqmm. lt cable 159 main lt panel at sub station- 400 kva (type a-2)lncomer- 1 set of 800 amp. tp mccb with spreader & extended handlemetering on lncomer - 1 set of digital ammeter with ass- 1 set of digatal voltmeter with vss- 1 set of led type phase lndicating light (22.5 mm.)with control mcbsoutgoing- 6 set of 250 amp. tp mccb with spreader & extended handte( 5 nos. + 1 no. for capacitor panel)- 2 set of 100 amp. tp mccb with spreader & extended handle 160 main lt panel at sub statton- 250 kva (type a-2) lncomer- 1 no. 630 amp. tp mdo acb with inbuilt mpr release with i ontoff tnai.ating lightmetering on lncomer - 1 set of digital ammeter with ass- i set oldigital volt-meler wirh vss- 1 set of led type phase indicating light (22.5 mm.j with control mcbs outgoing - 5 set of 250 amp. tp mccb with spreader & exrended handle- 2 set of 100 amp. tp mccb with spreader & extended handle flnstallation oflt distribution boards for lt underground system (type a,b&cj) 161 supply , installation, testing & commissioning of outdoor type feeder pillar panetto be made of 2 mm crca sheet and covers will be j.6mm crca sheet dulypowder coated paint with 300 amps al. busbar. (type-b2)lncomer - 250 amp. tp mccb - 1 no.outgoing - 63 amp. tp mccb - 5 nos.lnstallation of lt distribution boards forlt underground system (type-a, b & c) 162 outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. [type-b3] incomer - 100 amp. tp mccb - 1 no. outgoing - 63 amp. tp mccb - 4 nos.lnstallation of lt distribution boards for lt qnderground system [tvpe-a, b & cl 163 lockable distribution boxes of size 450x400mm with bus bar 100 amp. tpn to feed upto 10 houses (type c) 164 xlpe lt service armoured cable for single phase,2x6 sq. mm.(pvc armoured consumer service cablel 165 xlpe lt service armoured cable for single phase,2x10 sq. mm.(pvc armoured consumer service cablej 166 xlpe lt service armoured cable for three phase,4x10 sq. mm.[pvc armoured consumer service cablel 167 xlpe lt service armoured cable for three phase,4x1.6 sq. mm.(pvc armoured consumer service cablel 168 xlpe lt service armoured cable for three phase,4x25 sq. mm.(pvc armou[ed consumer service cable) 169 pvc pipe 32 mm dia 170 pvc pipe 50 mm dia 171 electronic kwh meter 1px2w with box. for single phase consumer 172 electronic kwh meter 3px4w static meter with box.for three phase consumer 173 carriage , laying of 3.5cx400 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 140 mm dia. 174 carriage, laying of 3.5cx150/240 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 1.20 mm dia. 175 carriage ,laying of 3.5cx70 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 75mm dia. 176 painting of stp incuding paints [2 ltr red oxide and 2 ltr alluminum paint for each pole.l 177 grouting of st pole 178 cartage , erection and dismentling charges 22% of materials cost 179 conversion of 11kv overhead/underground line by 11kv line underground 180 11 kv cable size 3x185 sq.mm xlpe 181 stp 11m-is 410 sp-55 182 g.l pipe 4 dia 183 top channel 100x50x2240 mm 184 hdpe pipe 160 mm dia pe 80, pn-6 185 service clamp o/s 186 clamp for fixing pipe to pole 187 11 kv cable jointing kit size 3x185 sq.mm xlpe o/d 188 11 kv cable jointing kit size 3x185 sq.mm xlpe s/t 189 earthing complete. 190 m.s. nut & bolt with washer 191 bracing angle 65x65x6x2700 mm with clamp 192 stone pad 193 number plates with clamp 194 danger board & clamp with bolts & nuts 195 stay complete 196 g i barbed wire 197 carriage , layrng of 3x185 sq.mm size 11 kv xlpe insulated cable underground in hdpe pipe dia 160 mm. 198 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 199 grouting of st pole 200 grouting of stay set 201 cartage , erection and dismentling charges 22% of materials cost 202 conversion of 33kv overhead/ underground line by 33kv line underground 203 cable al. 3x300 sq.mm. xlpe 33 kv 204 stp 11m-is 410 sp-55 205 g.l pipe 6 dia 206 m.s.top channel 100x50x2240 mm 207 hdpe pipe 200 mm dia pe 80, pn-6 208 service clamp o/s 209 clamp for fixing pipe to pole 210 bracing angle 65x65x6x4300 mm with clamp 211 33 kv cable jointing kit 3x300 se mm outdoor 212 33 kv cable jointing kit 3x300 se mm straight through 213 earthing of pole by ms earthing rod of 2ox25o0 mm & 6 swg earthr.ng wire etc. 214 m.s. nut & bolt with washer 215 number plates with clamp 216 danger board & clamp with bolts & nuts 217 stay complete (stay rod 15x1800mm, stay wire 5 kg,, stay clamp, boult & nut rvith grouting 218 daner bqard barbed wire includin jumpering 219 carriage , layrng of 3x300 sq.mm size 33 kv xlpe insulated cable underground in hdpe pipe dia 200 mm. 220 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 221 grouting of st pole 222 grouting of stay set 223 cartage , erection and dismentling charges 22% of materials cost 224 installation of 250 kva transformer on dp for the shifting of 3 no. 250 kva. 9 no.400 kva & 3 no. 630 kva transformer 225 stp 11m-is 410 sp-55 226 ms channel 100x50x2240 mm 227 service clamp for round pole 228 m.s. bolt and nuts off size with washer 229 l.t. cable 3.5ox4oo so m 230 ltxlpe insulated,unarmoured aluminium singlc corc cable,1x240sq. mm.sizc 231 lt xlpe insulatcd,unarmoured aluminium singlc core cablc,1x400 sq. mm.size 232 earthing of 250 kva t/f with g.i. pip[ 233 earthing rod complet. 234 1 1 kv d.o. fi]se sets 235 1 1 kv tpmo 236 d.d. wire 70 qs mm 237 250 kva t/f 238 l.t. cubical b0x complete 239 l,t. cable 3.50x240 sq mm 240 stay set complete, 241 aluminimum lug 70 sqmm 242 aluminimum lug 240 sqmm 243 aluminimum lug 400 sqmm 244 pvc tape 245 t/f bushing connector of copper strip 246 labour , cartage & errection charges and dismentaling of existing t/f 247 dismentling and cartage from site to store charges 7% (other misclenous charges)
  • View Tender
  • Document
  • Bid Support
4 Security Services
image image
Central Government/Public Sector
TRN :48280497 |  17 May, 2025
Tender Value : 4.14 Crore
 Leh - Ladakh
Tender for tender for provision of central mi room at nimu(job no 01/nimu stn/amwp/2023-24); 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 43 2 lump sum price worked out by the contractor for (site clearance, excavation & earth work)as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 44 3 lump sum price worked out by the contractor for (internal electrification)as listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 50 4 lump sum price worked out by the contractor for (internal water supply)as listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 52 5 lump sum price worked out by the contractor for (road, path & hardstanding)as listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 54 6 lump sum price worked out by the contractor for (sewage disposal)as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 55 7 lump sum price worked out by the contractor for (area drainage)as listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 56 8 lump sum price worked out by the contractor for (shed for dg set)as listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 58 9 lump sum price worked out by the contractor for (hot water supply)as listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 59 10 lump sum price worked out by the contractor for (external electrification)as listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 65 11 lump sum price worked out by the contractor for (external water suplay)as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 66 12 sch a part - xii (misc b/r & e/m items) (refer boq)note: this schedule is not pre-priced by mes and the rate indicated as rs 0.00 under col 5 signifies this fact only 13 internal electrifications&f double door three phase prewired distribution board vertical db vtpn 8 way with acrylic door made out of crca sheets 1.6 mm thick,phosphatised powder coated with copper bus bar 200 amps, 415 v,ip 43/ik09, earth stud, din rail, polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingmccb4 pole 63 amp rating repturing capacity 16 ka.(note:- single phase mcbs are to be measured and paid for seperately) 14 s&f led building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240v, ip 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long med grade gi pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith ms clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm pvc insulated 3 core wire complete all as directed and specified by engr-in-charge.note - cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 s&f new wall mounted fan of approved make and type complete all as specified and as directed. 16 s&f tv co-axial socket 1 module, complete all as specified and as directed. 17 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole mcb 20 amps 18 internal water supplys&f single piece vitreous china wash down water closet pan pedestal pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type b-0, as in repairs complete all as spd & directed complete all as specified and directed by engr-in charge.. 19 s&f cp grating including jointing to waste pipe fixed in cement concrete type b-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by engr-in charge. 20 s&f hand shower (health faucet ) with 8mm dia and 1 meter long cp flexible tube and wall hookcomplete all as specified make: cera, jaquar , marc & hindware as per sample and directed by engr -in charge 21 s&f soap dish (s/s), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by engr-in charge. 22 road, path & hard standingm&l for wet mix macadam (wmm) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of morth (ministry of road transport & highways) specification of road and bridge works 2013. manufactured in wmm plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 kn static weight and conslidating required gradient and camber. the finished surface tolerance to be as per table 900-1 of morth specification for road and bridge works 2013 complete all as specified and directed by engr-in-charge. 23 m&l for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to bs 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 m&l for rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m-30 design mix in walls , base slab , baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 m&l for soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonary in cm, rcc cover slab in m25/ sfrc cover, interconnecting pipes of rcc/dwc complete filled with brick bats of size 3m dia and 3 m depth. 26 s&f pvc junction boxes ip 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 nos mcb sp 2.5 amp & 4 way industrial connector including clamp made out of ms flat 30x5mm connection from junction box to street light fitting with three single core pvc insulated, pvc sheathed wire 2.5 sqmm copper & pvc conduit 20 mm dia complete all as specified and directed by engr-in-charge. 27 excavation in trenches by cutting of road crossing/pcc hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by engr-in-charge. 28 s&fht/lt ms cable route indicator 4 dia fixed with two nos of nut, bolt and washers and provision of pcc 1 : 4 : 8 type d-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by engr-in-charge. 29 supply, installation, testing and commissinoning lt panel board suitable for working on 3 phase ,4 wire ,415 volts, ac ,50hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick crca sheetduly powder coated and shall be cpri approved and as approved by ge. the panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, copper bus bar duly covered with heat shrink sleeves colour coaded duly fixed ondmc/smc insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing mccbs shall have extended bus bar links and mounted on 50x50x5mm sizems angle iron frame duly painted including pcc 1:2:4 type b1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of age (i) nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) mccb 400 amps, fp, 36 ka, 415 volts, 50hz - 01 no (i/c)(b) mccb 200 amps, fp, 25 ka, 415 volts, 50hz - 02 no ( chs)(c) mccb 125 amps, fp, 18 ka, 415 volts, 50hz - 04 nos (apfc, tpn db -02, spare )(d) mcb spn 40 amps, 10 ka, 220 volts, 50hz - 03 nos (garage,street light, spare-1)(e) on load chengeover 630 amps 4 pole -01 no (f)digital voltmeter, with vss - 01set(g) digital ammeter, with cts & ass - 01 set(h) led phase indication lamps ryb - 01 set(j)single phase rotary automatic light controller nature switch with voltage range 120-440v,ac,20 amps,ip-65,50hz-01 nos(k) copper bus bar tpn 600 amps rating - 01 set 31 labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and gi tubing in soft/loose soil complete all as specified. 32 m&lfor cutting existing gi pipes and insertion of new tee branches of suitable size to take branch connection of 50mm dia pp-r.note : suitable size of tee branch is deemed to be included in the quoted rate. 33 construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingpcc in foundation of the mixture (1:4:8) d-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) ms steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed ms work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in pcc with two coats of black bituminuos paint andall other relevant work complete . 34 m&l for providing tracer/anti freezing cable required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (central heating system)electric hot water generator : supply, installation, testing and commissioning ofpackage type electric hot water generator constructed out of ms sheet having top open-able cover for easy access and removal of heaters. the hwg shall be suitable for indoor mounting. the generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22g aluminium cladding sheet. the generator shall have electrical capacity of 50 kw. the heater shall be electrical resistance type, copper tube with chromium plating. the generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. the generator shall be suitable for 3 phase, 415+ 10% volts, 50 hz. ac supply. the generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 notes:- (i) allneccassary accessories required for the proper fucntioning of hot water genearator are included in price.(ii) the prices should include lifting, shifting and positioning of units at site.(iii) hot water genearator installation to done as per manufacturer recommendation with all installation requirements i.e foundation, vibration isolator,insulationetc as recommended by manufacturer for the ambient temperature of site. odu installation is included in odu price which includes the civil struture, mechanical structureetc as recommended bymanufacturer.(iv) the contractor/oem will shall submit the hot water generator capacity/burner capacity conforming to relevant is code(v) oem should submit the installation and maintenance schedule/ manual for the boiler. 37 glycol circulation centrifugal pumps: supply, installation, testing & commissioning of pn16 ratedaxial split coupled vertical inline water pump set with ci casing, bronze impeller, ss shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with suitable hp, tefc squirrel cage induction motor with ie3 type class f insulation, motor shall be rating of ip 55, operating on 415 ±10% volts, 3 phase, 50hz ac supply. the external flush line must be used for the purpose of heat dissipation from the mechanical seal.pumps with performance characteristics as given below:the internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 degree celcius to 120 degree celcius. vendor shall be provide antivibration arrangement for pumps . 38 the scope also shall include following below mentioned:(i) electrical by pass starter for pump setas recommended by oem. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) pressure gauges 150 mm dia -03 nos (iv) mounting frame with antivibration pads (in case pumps are inline, anti vibration system shall be as per manufacturers recommendation) (v) rcc/cement concrete foundation for the pump unit. (in case pumps are inline, foundation shall be as per manufacturers recommendation).pump capacity are as under:capacityand pump headnot less than flow 25 usgpm , head 20 mtr (refernce model no. : armstrong : series 4300 - 40-150 - 2p - 1.5 kw) each including the triple duty valve and end suction guide. 39 expansion tank and pressurisation unit:supply, installation, testing and commissioning of insulated pressurised closed water expansion tank suitable for total volume ofglycol - water solution, circuit along with necessary accessories such as along with necessary accessories such as 2 nos pumps (1working +1standby) with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. the tank shall be pre-charged. expansion tank shall be with replaceable heavy duty butyl rubber bladder. the tankconnections should be as per oem recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.the tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. the tank must be constructed in accordance with is-standard 2825-1969 (withlates revision)and rated at pn 16 . the complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.the tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelip55 control panel, pressure transmitter, interconnecting piping & wiring. (tank capacity 500 ltrs). hot glycol - water closed vessel pressurized expansion tank as described above shall be duly insulated with 50 mm thick puf/nitrile rubber insulating material or equivalent u valueinsulating material and cladded with aluminium sheet (20g). electrical by pass starter for pump setas recommended by oem. 40 expansion tank of 500 lts capacity 41 pressurization unit: for pump set -03 nos with control panel and accessories. 42 make up tank: supply, installation, testing and commissioning of factory made make up water tank, rectangular/circular shape, of 4 mm thick ms sheet (is 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of ms and vent with flame arrestor. tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above ffl. service platform shall be provided as per recommendations of oem. the tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. extra high level and extra low level alarm shall be provided. tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.make up water tank as describedabove should beduly insulated with 50 mm thick puf/nitrile rubber insulating material and cladded with aluminium sheet (20g). 43 supply, installation, testing and commissioning ofsteel plate radiator( wall mounted) confirming en- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°c, complete with top grill side cover as standard along with inlet ,outlet valve, air purge valve andwith threaded plug, flow regulator as per oem.the below desired capacity should be calculated at altitude of 3600 mts above sea level. capacity calculation sheet to be provided to engineer in charge. the below mentioned capacity is at inlet temp: 75 degree celcius , outlet temp: 65 degree celcius. referemcwe model series. 44 1.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 45 2.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 46 3.5 kw,type: 33- dkek, length is 1600 mm and height is 600 mm of radiator. 47 5 kw,type: 33- dkek, length is 1600 mm and height is 900 mm of radiator. 48 5 kw,type: 33- dkek, length is 2000 mm and height is 600 mm of radiator 49 m & l for pre-insulated ms pipe,class c havingminimum thicknes of puf insulation as mentioned below and of density 36 kg/cum and 26 gauge al cladding complete suitable for above ground as per sizes shown.the pipes should be insulated with closed cell puf of density 36±2 kg/cum of below mentioned thickness. the pipe should be workable in the temp. range of-50 degree celciusto120 degreec celcius. note:-the pipes size 150mm & below shall be m.s. ‘c’ class as per is : 1239 50 80 mm with 36 mm puf thicknes and 26 gauge al cladding. 51 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 52 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 53 40 mm with 36 mm puf thicknes and 26 gauge al cladding. 54 20 mm with 36 mm puf thicknes and 26 gauge al cladding. 55 buried under ground/exposed to ambient:80 mm with 50 mm puf thicknes and hdpe cladding, 26 gauge al cladding. 56 cabel tray :-supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ground/wall with m.s. suspenders as per is code including bolts & nuts, painting suspenders etc. as required of size 150 mm width x 50 mm depth x 1.6 mm thickness 57 supplying, fixing, testing and commissioning of following diameter valves (pn-16 rating) (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), strainers (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), gauges etc for condenser water circulation as per specifications. insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified. butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets.butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets. 58 80 mm dia butterfly valve 59 65 mm dia butterfly valve 60 50 mm dia butterfly valve 61 supplying, fixing, testing and commissioning of y-strainer (insulated valves) of ductile ci body flanged ends with stainless steel strainer forhot water circulation including insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified of size 50 mm dia y strainer. 62 supplying, fixing, testing and commissioning of non - return valve (insulated valves) with duel plate of ci body ss plates vulcanized nbr seal flanged end & pn 16 pressure rating forhot water circulation includinginsulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as sepcified of size 50 mm dia nrv. 63 supplying, fixing, testing and commissioning of automatic air purge valves forhot water circulation headeras specified of size automtic air purge valve 20 mm dia. 64 supplying, fixing, testing and commissioning of air separator compleate allas specified of size 50 mm dia. 65 supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and ss tubing, socket.range (0-50) / (0-100) as required by engineer in charge. 66 supplying, fixing, testing and commissioning of mercury in glass industrial thermometer in ss-304 casing with 0.5 c least count, range 0-50 c. brass oil filled thermowell of 1/2 size as required by engineer in charge. 67 electrical distribution panel supply, installation, commissioning and testing of factory made, chs plant, indoor type made out of crca sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with ms angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 phase4 wire, 415 volts, 50 hz, ac supply system, floor mounted and grounting the legs of panel in pcc foundation 1:4:8 complete as all directed suitable for and including the following :- 68 incomers(i) bus bar tpn al extensible type main bus bars of minimum of 600 a capacity (as per capacity of corresponding incoming / bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c smc bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50ka .(ii)mccb 400 amps, 415 volt, 36 ka, 4 pole,microprocessor release- 01 no for incoming (extended rotary operating handle, phase spreader links and phase barriers ) make: legrand/schenider/simensoutgoings(i) 3nos- 125a ,25 ka tpnmccb/acbwith microprocessor release (3# hot water generator)(ii) mcb 10 amp,tpn,10ka, c curve - 06, 3 nos for pumps , 2 nos for pumps ,01 nos for glycol transfer pump(iii) led phase indication lamps (01 set) with 2amp back up mcb,breaker on/off indicating light with 2a mcb, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 set (iv) digital ammeter with in built ass,metering c.t.scast resin type, 15va, and accuracy class-1of 800/5a for measuring current in each phase - 01 set.(v) all accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per manufacturers recommendations all as directed by engnr-in-charge.note : contractor will submit the drawing for approval of panel to ge before execution. 69 lt cables : supply & laying/ fixing of following size xlpe insulated and pvc sheathed copper conductor armoured cable/unarmoured as required of 1.1 kv grade complete as require (isi marked) (in ground/in pipe/in duct/on surface/on cable tray) 70 3.5 core x 70 sq.mm. (electric hot water generator) 71 4.0 core x 10 sq.mm. (pump) and (pressurization unit) 72 2 core x 10 sq.mm. (pump) 73 2 core x 6 sq.mm (pressurization unit) 74 earthing complete with copperearth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long gi pipe connected to main controlboard and gi pipe light grade 20mm bore for watering and including funnel, wire mesh, rcc pit cover 50mm thick and pcc chamber pit with pcc 1:2:4 type c2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate no 3 of ssr part-i 2009 complete all as specified & directed by engr-in-charge 75 s&f rubber matting conforming to is-15652-2006 complete as required. of size2m x 1m x 25 mm 76 glycol - water solutionsupplying of ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.note;- (i) the glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. the glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 degree celcius (ii) first charge of glycol is included in the quoted rate. first charge include charge in chs pipe linestorage tank. (glycol 45 % ,water 55 %) 77 for chs 78 supply of gycol for running of plant for 12 months 79 glycol circulating pump: supply, erection, testing and commissioning oftransfer pumps for the capacity of 5 lpm 5 meter head for glycol fluidtransfer with base frame foundation, bolts coupling coupling guard,tefc, (oem design hp for the required flowand head ) andother accessories for proper function of the pump. 80 oxygen gas manhold : supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, nrv and essab make 10x14 regulator complete all as specified and directed by engr in charge . 81 supply , installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by engr in charge . 82 supply , installation , testing and commission automatic control panel with analog display 02 for oxygen complete all as specified and directed by engr in charge. 83 s&f of copper tubing of size 15 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 84 s&f of copper tubing of size 12 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 85 s&f bs type gas outle with probe for oxygen for medical compleate all as specified and directed by engr in charge 86 s&f 1/2 brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by engr in charge. 87 s&f bpc flow meter (0-15 lpm) including humidfire bottle complete all as specified and directed by engr in charge . 88 s&f 3/8 brass ball valveincluding all fittings for complete all as specified and directed by engr in charge. 89 stand by dg set : supply,install, test and commissioning of silent diesel engine generating set 415 volts, 3 phase, 4 wireengine as per is08528 conforming to cpcb norms iv, and alternator as per is08528 of capacity 400 kva at ntp with control panel having meters, sound proof canopy etc with foundation (as per oem design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- ac generator should be suitable for ambient conditions at nimu leh area. 90 (a) alternator : standard design alternator rated at 400 kva (320kw)net output at power factor 0.8, ac, 3 phase 4 wire, 415 v, 50 cycles/second, 1500 rpm self excited, self regulated, screen protected, drip proof ip 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (b)diesel engine : vertical diesel engine of suitable capacity, water cooled, closed circuit as per bs-649 or is-1002 direct injection type turbo charged, electric starting system having rated speed 1500 rpm. the dg set shall be capable for running with 10% over loading for 01 hour in every 12 hours as perbs-5514/bs-649. engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following specifications.(a) fly wheel with housing (i) common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) cooling system (i) radiator with fan & belts & guard, rubber hoses and thermostat. (ii) cooling water pump centrifugal type . 91 (c) governer : electronic governer (d) electric starting system : electric self starter , 24 volts dc(12 volt, 150 ah battery 2 nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2x12 volt 150 ah capacity. (e) generator monitoring panel : comprising of following :- (i) microprocessor based genset controller for metering, monitoring, governing and protection. (ii) engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) accessories:avm pads built or separately mounted to manufacturer base frames. (g) coupling arrangements: fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) exhaust system : should have equipped with emission control device as per latest govt norms. silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) fuel tank: daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (c)acoustic enclosure : all as per cpcb norms iv and oem of dg sets design.(d)amf panel : supply, install, testing and commissioning of amf panel outdoor type, cubical body,dust and vermin proofmade up of crca sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to ip 45 with front and rear opening with louvers andmounted on floor with pcc pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) microprocessor based panel -01 no(ii) power contactor heavy duty suitable for generator and mains (iii) over load relay for genset (iv) suitable rating isolating switch mccb for both dg & main supply.(v) multi functioning meter to indicate voltage, current, frequency, p f, kw & kwh etc (vi) emergency stop push button.(vii)set of indicaters : - (a)low lube oil pressure (b) dg set over load(viii) push button to start, stop (ix) mode selector switch i.e auto/manual/test/ off.(x) set of instrument fuse (xi)set of aluminium bus bar of 600 amps capacity 3 ph, 4 wire system (xii) automatic battery charging unit with dc voltmeter, ammeter and selector switch for trickle/ boost charging.(xiii) by pass arrangement of main supply when amf circuit fail due to any fault with provision of suitable rating change overs and switches. 93 the following items are deemed to be included in the rate quoted for all dg sets:- (i) dhpp for testing purpose shall be supplied by the contractor without any extra cost to department. (ii)the contractor shall arrange for artificial load (water load/electrical load) for testing for final testing of dg set at site and the cost is deemed to be including in above offer. (iii) testing of sound level should carried out at the site in presence of engineer-in-charge(iv) one set of latest spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) all civil works including foundation for dgset as per manufacturers drawing/ specification, foundation for amf panel shall deemed to be included in the quoted rate.(vi) the rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : digital vibration meter
  • Micro Pulse Lider Tenders ,
  • Photo Elastic Equipment Tenders ,
  • Optical Contact Angle Tenders ,
  • Cell Disruptor Tenders ,
  • Electroporation System Tenders ,
  • Microarray Tenders ,
  • Fpga Trainer Kit Tenders ,
  • Ctd Profiler Tenders ,
  • Orifice Tenders ,
  • Bar Pendulum Tenders

Get digital vibration meter Tender Alert...

540015

Related Searched Keywords : digital vibration meter

  • Lift Irrigation Tenders From Maharashtra
  • Stone Cladding Tenders From Delhi
  • Culverts Tenders From West-Bengal
  • Flooring Tenders From -Tamil-Nadu
  • False Ceiling Repair Tenders From Andhra-Pradesh
  • Rcc Fencing Tenders From Gujarat
  • False Celling Tenders From Karnataka
  • Table Tenders From Uttar-Pradesh
  • Buildings Repair Tenders From Rajasthan
  • Rcc Dam Tenders From Madhya-Pradesh

Read More


Tender Document

746616

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Building Work Tenders
  • Ceiling Tenders
  • Plastering Tenders
  • Pile Foundation Tenders
  • Civil Engineering Service Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App