Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Drilling Boring
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of drilling-boring Tenders

List of latest drilling-boring Tenders in Indian Tenders. Click on any drilling-boring Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for drilling-boring Tenders.

Advance Search
  • All-Tenders (6)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49055023 |  12 Jun, 2025
Tender Value : 4.85 Crore
 Bengaluru Urban - Karnataka
Tender for tender for provision of deficient smqs at af stn chimney hills; 2 general summary note: schedule ‘a’ part i to xii are prepriced by mes under ser no. 1 to 12. bidders shall insert their lumpsum amount in the green coloured field under col-6 only. 3 lumpsum price worked out by the contractor for “internal water supply” as listed in schedule ‘a’part–ii 4 lumpsum price worked out by the contractor for “internal electric supply as listed in schedule ‘a’part–iii 5 lumpsum price worked out by the contractor for site clearance and development as listed in schedule ‘a’ part - iv . 6 lumpsum price worked out by the contractor for road / path / culvert as listed in schedule ‘a’ part - v . 7 lumpsum price worked out by the contractor for area drainage as listed in schedule ‘a’ part - vi . 8 lumpsum price worked out by the contractor for sewage disposal as listed in schedule ‘a’ part - vii . 9 lumpsum price worked out by the contractor for “fencing” as listed in schedule ‘a’ part – viii. 10 lumpsum price worked out by the contractor for “protective works” as listed in schedule ‘a’ part – ix. 11 lumpsum price worked out by the contractor for “external water supply” as listed in schedule ‘a’ part – x 12 lumpsum price worked out by the contractor for “external electric supply” as listed in schedule ‘a’ part – xi 13 lumpsum price worked out by the contractor for “hot water supply” as listed in schedule ‘a’ part – xii 14 schedule a part - idesign and construction of married accommodation building in 3 storey (ground+2 storey)in framed construction with permanent specifications in rcc of grade as per structural drawings, aac block masonry walls, att, pu based wpt, earthquake resistance as per latest is, green building norms with minimum 3 star griha rating etc complete all as specified and as shown on drawings. 15 design and construction of car and scooter parkingshed in rcc framed construction with permanent specifications in rcc of grade as per structural drawings, aac block masonry walls, pu based wpt, earthquake resistance as per latest is, green building norms with minimum 3 star griha rating etc complete all as specified and as shown on drawings. 16 sch a part - xiii : fittings / fixtures & misc items. internal water supply supply and fix 15mm bore kitchen sink tap, brass chromium plated dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed. 17 supply and fix 3 in 1 chromium plated wall mixer for mixing hot and cold water (for shower) screwed down for iron pipe and fixed complete all as specified and as directed. 18 internal electric supplysupply and fix modular tv socket, one module all as specified and directed by engineer in charge. 19 supply and fix modular telephone socket, rj-11, one module all as specified and directed by engineer in charge. 20 material and labour for telephone wiring with unarmoured solid annealed bare copper industrial cablein concealed of size 0.5 mm, 3 pair with pvc conduit 25 mm diaall as specified and directed by engineer in charge 21 material and labour for tv wiring with unarmoured coaxial cable, rg-11 in concealedwith pvc conduit 25 mm diaall as specified and directed by engineer in charge . 22 material and labour for mild steel box for telephone wiring including blocks, suitable for 30 pair all as specified and directed by engineer in charge. 23 material and labour for earthing complete with galvanised steel pipe electrode of size 40 mm bore, medium grade, 2.5 meter length, burried directly in ground in bore 350 mm dia vertically to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to galvanised earth lead wire 4.0mm dia by meanswith bolts, nuts check nuts and washers protected by gl light grade pipe of size 15 mm dia and connecting up with the db as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, pcc chamber, rcc cover(yellow painted) with handle, watering pipe 20mm dia gi medium grade with funnel and wire mesh, charcoal dust , salt, mild steel earth markerwith earthing result, date all as per plate no.2 of ssr 1991 and as directed by engineer in charge. note:-boring charges are included in the above quoted rates 24 smart meter systemdesign, supply, installation, integration, testing and commissioning of smart meter with prepaid metering facility, ac single phase, two wire, 240 volts, 50 hz , 10 to 60 amps all as per bis 16444:2015 (reaffirmed 2020) with plug in type bi- directional communication module (the plug in module shall be field swappable /replaceable), includingnecessary communication infrastructure suitable for integration with approved communication technology gprs/rf/hybrid (gprs+rf) /any other advance technology as per cea /trai regulations etc.easily adaptable for network interface and integration with advance metering infrastructure (ami) of the project area complete in all respect all as specified and as directedby engineer-in-charge. 25 tv & telesupply and fix pvc conduit 25 mm diaconcealed in wall all as specified and directed by engineer in charge . 26 material and labour for tvwiringwith rg-6 solid copper coaxial audio and video cable for tv antenna, satellite, dvr devices, safe for using in door and out door and drawn through pvc conduit upto required length,all as specified and directed by engineer in charge. 27 material and labour for telephonewiringwith 0.4mm pvc telephone switchboardcablefor telephone , safe for using in door and out door and drawn through pvc conduit upto required length, all as specified and directed by engineer in charge. 28 supply and fix telephone distribution box ,junction box with krone module for multiple connection, all as specified and directed by engineer- in- charge. 29 external water supplymaterial and labour for drilling and tapping gi/ci water mains (in position) for branch connection of 150/100mm including all fittings such as bend, elbows, tees, reducers and unions etc all as directed by engineer in charge. 30 supply and fix brass-metal, 100 mm diaglobe gate valves, with iron wheel head, screwed both ends for iron pipe all as specified and directed by engineer in charge 31 material and labour for construction of brick masonary valve chamber of size 900mm x 900mm x 600mm internal size including necessary earth work excavation, pcc 1:4:8 type d2 for foundation, brick work in cement mortar 1:4, pcc 1:2:4 type b1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40 x 40 x6 mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as directed. 32 material and labour for construction of brick masonary valve chamber of size 600x600x600mm internal size including necessary earth work excavation, pcc 1:4:8 type d2 for foundation, brick work in cement mortar 1:4, pcc 1:2:4 type b1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40 x 40 x6mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as directed. 33 external electric supplymaterial and labour for cutting road / hard standing to depth not exceeding 60 cm and to width not exceeding 45 cm for laying hdpe pipes and making good the disturbed surfacesby 1:3:6 type c1 using 20 mm graded stone aggregate complete all as specified and as directed. 34 supply, install, testing and commissioning of cpri approved lt panel outdoor type of size 1.5x1.2x0.60 mtr suitable size recommended by manufacturercubical floor mounted type (ip-65 degree of protection ) made out of 3 mm thick ms sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 200 amps rating made of aluminium strip (40x5mm) duly drilled holes for connections and mounted on epoxy based post insulatorsfor 3 phase 4 wire 415 volts 50 hz ac supply ,hibling , cable entry boxes , cable gland incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type c1 with 20 mm graded stone aggregates totally tested as per iec 61439-i with the following accessories. 35 incomingmccb 125 amps 25 ka adjustable type 4 pole -01 no@ as in/comingoutgoing(i) mccb 63 amps 25 ka adjustable type 4 pole -03 nos@ as out/going (working-02 , spare-01)(ii) mcb 32 ampstpnamps adjustable type as per - 03 nos@ as out /going(working-02 , spare-01)(iii)multifunctional digital type timer switch230v 50 hz, single phase40amps cap with bay pass system including power cotactor suitable 40 amp mcb 40amps toggle switch cut out of40amps. (iv) powercontactor for rex timer switch 4 pole 40 amps -01 no(v)multifunctional digital type adwancedthree phase meter volt/amp/kva/kw/ +/- 1.0% rated current, auto and manual scrooling,site selectable ct/pt ratios 80/5 etc.housing in ms sheet 1.6 mm thick duly painted with enameled paint over a coat of primer complete in all respect all as directed & specified(vi) phase indicators led type set of 3 - r,y,b -o1 setnote :- foundationfor fixing of lt/feeder pillerboard in ground floor pcc (1:4:8) type b-1 using 20mm graded stone aggregate, measured and paid separately 36 supply and fix smc loop in loop out pvc water proofjunction box of internal size 200 x 140 x 95 mmincluding mcb 6 amps,b class ,connector necessary ms clamps, nuts & bolts with washers etc required at site all as specified and as directed. 37 material and labour for pvc insulated, pvc round sheathed multicore industrial cable of size 3 core,1.5 sqmmfor voltage grade upto 1100 v, as per is 694 all as specified and directed by engineer in charge. 38 returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. note:- excavated soil shall be riddled by using sieve to separate composite particles etc as per is 1255 1983 and refilling in trenches as in cable cushioning. 39 supply and fix gi bracket made out of light grade pipe of size 40 mm dia 1.2 mtr long bent to shape including ms clamp of suitable size nut bolt washer for fixed along the wall/pcc pole with ms clamp etc complete all as specified and as directed. 40 supply and fix mccb 3 pole, 415 v, adjustable type, 125 amps with breaking capacity 25 ka, at existing lt panel and making good connectionwith nut bolts and washers and wire connections etc. to be fixed in theexisting tr panel complete all as specified and as directed. 41 m & l for earthing complete with gi earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m belownormal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 25x4mm gi stripby means of bolts, nuts, check nuts and washers of galvanized iron upto test pointand protected by gi pipe light grade 40 mm bore up to 7.5 mtr connected to a main switch board or main control board and gi pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast rcc 1:2:4, type b-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 kg/sqm in lieu of ci cover, pcc 1:3:6 type c2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in electrical plate no3 of mes schedule part – i of 2009.
  • View Tender
  • Document
  • Bid Support
2 Panchayat Division
image image
State Government
TRN :49067970 |  19 May, 2025
Tender Value : 80.00 Lacs
 Jaipur - Rajasthan
Tender for drilling of tube well, installation of hand pump, single phase boring and motor pipe with power connection work.
  • View Tender
  • Document
  • Bid Support
3 Water Supply And Drainage
image image
State Government
TRN :49068153 |  14 May, 2025
Tender Value : 60.09 Lacs
 Charkhi Dadri - Haryana
Tender for tender for connecting of newly constructed rcc tank from existing tank- 1 ns item 2 supply, erection, testing and commissioning vfd control panel unit consists of ms box of size 1800mmx 3600mm x x 600mm on angle iron frame duly painted with powder coated paint with powder paint with following accessories (for 10300 lpm 30 mtr head pump set of 120 hp):- a) 120 hp drive ( nvt) – 1 no.b) 400 amp. mccb (landt) – 1 no.c) 400 amp. fuse switch – 3 no. d) on/off switch-2 no. e) ryb indicator – 1 no. f) on indicator- 1 no. g) trail indicator -1 no. h) vaf meter – 1 seti) ct 200/5 – 3 no. j) glass relay – 1 no. complete accessories duly fitted with 50 mm copper wire including cost of thimbles, lug, mcb channel, slives,, nut and bolt complete in all respect 3 supply, erection, testing and commissioning of non-clog seweage submersible pumping set of discharge 10300 lpm, 30 mtr head ( 120 hp) 1450 rpm with 50 mtr cable of suitable size and autcoupling- ss chain 30 mtr, ss-304 guide pipe and pmu control panel complete in all respect 4 drilling/boring by trenchless technology for pushing of 900 o/d hdpe pipe (rat drilling / jack pushing method) by erecting the equipments to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in all type of soil excluding hard rock and pushing the casing pipe including cost of all type of material i.e. tools, jims, ropes and all other accessories required for drilling 5 lowering of sub soil water upto a depth of 14 mtr including cost of all type of equipments i.e pumping machinery, drilling of tubewell, lowering of pump set, pipes complete in all respect
  • View Tender
  • Document
  • Bid Support
4 Security Services
image image
Central Government / Public Sector
TRN :34441973 |  10 May, 2025
Tender Value : 0
 Kanpur - Uttar Pradesh
Tender for gem bids for 4200 low viscicity high performance chlorine free neat cutting oil for deep hole drilling boring operati
  • View Tender
  • Document
  • Bid Support
5 Security Services
image image
Central Government/Public Sector
TRN :48475497 |  17 May, 2025
Tender Value : 37.70 Crore
 Jaipur - Rajasthan
Tender for tender for provision of klp (ph-ii of two phases) for engr regt at jaipur mil stn; 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 2 lump sum price worked out by the contractor for internal water supply as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 3 lump sum price worked out by the contractor for internal electrificationas listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 4 lump sum price worked out by the contractor for road, path and culvertas listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 5 lump sum price worked out by the contractor for sewage disposalas listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 6 lump sum price worked out by the contractor for area drainage as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 7 lump sum price worked out by the contractor for rain water harwestingas listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 8 lump sum price worked out by the contractor for external water supplyas listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 9 lump sum price worked out by the contractor for external electrificationas listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 10 lump sum price worked out by the contractor for parade ground of size 137 m x 91 m, footbal/hockey 02 nos, basketball courts 02 nos, volley ball courts 02 nos, hardstanding & badminton court 01 noas listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 11 lump sum price worked out by the contractor for compound wall, chain link fencing and gate as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 12 lump sum price worked out by the contractor for hot water supplyas listed in schedule ‘a’ part-xii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 13 lump sum price worked out by the contractor for refrigeration and cold water supplyas listed in schedule ‘a’ part-xiii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 14 lump sum price worked out by the contractor for site clearance, site developmentand earth workas listed in schedule ‘a’ part-xiv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 15 lump sum price worked out by the contractor for addn/altn of existing buildings & structures (b/r)as listed in schedule ‘a’ part-xv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 16 lump sum price worked out by the contractor for addn/altn of existing buildings & structures (e/m)as listed in schedule ‘a’ part-xvi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 17 lump sum price worked out by the contractor for demolition of buildings & shedsas listed in schedule ‘a’ part-xvii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 18 sch a part-xviii misc items (to be quoted by contractor) notes:(i) this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under column 5 signifies this fact only. (ii) excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under sch a part-xiv (site clearance, site developmentand earth work schedule). 19 pop ealse ceiling for sch a part i building work (officers mess & adm block)m&lforpop false ceilingof approveddesignconsisting of 10mm thick plaster of paris ceiling (gyspsum anhydrous) board including gi frame work for 12mm seamless ceiling comprising of gi perimeter channel of 0.55 mm thick with two unequal flange of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre intermediate channel 0.5 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm centre to centre with gi cleat and tee, expansion fasteners with and including ceiling section (not exc 1.2m length)of 0.55mm thickness having curved web of 50mm and flange of 26mm each with clips of 10.5mm fixed to intermediate channel with connectingclips across the intermediate channel of 457 mm centre to centre complete. 20 internal water supply (sch a part-ii) s & f 15mm bore angle valve/cock cast copper alloy fancy type screwed down high pressure with cructh or butterfly handle screwed both ends for iron pipe or brass ferrule fixed. make - cera-f1012201, jaquar - ari- chr-39053, kohler - k-80154in-4-cp 21 s & f wall mixer/diverter with diverter plate of bathroom 3 in 1 system with provision for both hand & over head shower with 115mm long bend pipe ( for mixer) connecting legs & wall flangs complete all as specified. make: cera-f1022403, jaquar-flr-chr-5281n, hindware-flora f280022 22 s & f chromium plated brass bath tub spout with wall flange(fancy type) suitable for 15mm bore pipe complete all as specified and directed. make- cera-f1012661, jaquar-spj-chr-429, hindware-f-520009 23 internal electrification (sch a part-iii)supply and fixing sp 63 amp rating, 240v, 10 ka c curve miniature circuit breaker (mcb) of following poles and current carrying capacity in the mcb db complete with connection testing and commissioning complete all as specified and as directed. 24 supply and fix tv coaxial,1 module socket complete all as specified and as directed. 25 s&f telephone socket(jack type) ,1 module rj11 with shutter complete all as specified and as directed. 26 m&l for electrolyte grade solid annealed copper conductor,jelly field,aluminium foiled and aluminium wire braided, rg59 (foam). cat part no. whojttkarg59make- havells or equivalent in as mentioned in appx b of particular specification 27 m&l for pvc insulated telephone cables for indoor applications confirming to technical specification g/wir06/02 cat part no.whttatea1p40 make-havells or equivalent in as mentioned in appx b of particular specification 28 s & f for highly efficient led bulbs, 9 watt complete all as specified and directed. make bajaj/havells/hpl 29 s & f blanking plate complete all as specified and directed. 30 s & f of sheet metal enclosure distribution board vtpn ,4 way, 415 volt, double door powder coated, protection class ip-54, isolated neutral bar, mechanical impact strength ik 09 suitable for mounting mcb & mccb dbs confirming to is-13032, is-8632,bs5484 with min 200 amp raiting copper bus bar and grouting, fixing on wall with nut boldts washers proper with pcc works complete all as specified and directed 31 rain water harwesting(sch a part-vii)borewell for rain water harvesting all as specified and shown on drg : (a) provision of trail bore by drilling with reverse rotary system550mm bore upto 52 m depth incl all works pertaining to boring complete in all respect in aluvium soil/ strata incl hard stone / boulder etc.(b)m&l for 150mm bore cpvc pipe assembly jointing, lowering in any position upto the reqd depth below given level incl jointing the pipe by solvent & screwing 04 nos screws in each joint complete all as directed.(c) ditto as item (b) above but slotted pipe(d) m& l for packing with pea gravel of 4.6 mm to 8mm size of approved quality as ordered to pack arround the casing / slooted pipe in borewell all as directed.(e) m&l 25 mm bore perforated cpvc pipe 52 mtr long for vent pipe 32 external water supply(sch a part-viii). m& l for cutting of existing pipeline of 100/150/80 mm dia for taking branch connection alongwith insertion of di tee and connecting material such as joint, nut bolts, etc all as required at site. 33 m&l for construction ofbrick stone masonary valve pit / chamber of size 900 mm x 600 mm x 1000 mm (internal dimensions) all as shown in drawing no td-573, including necessary excavation and earth work, pcc, plaster in cm 1:6 on inside and outside (above ground), ms angle iron 40 x 40x6.0 mm thick complete all as specified and directed and shown on drawings. 34 all as per item no 33.00 but chamber size 450 mm x 450 mm x 600 mm (internal dimensions) complete all as specified and directed 35 supply and fix stop valves 63mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed 36 external electrification . (sch a part-ix)supply and fixing led street light fitting 36 wattefficacy greater than 100 lumen/watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete all as specified and directed. make : phillips, cat no brp046 led 36 cw mr s1 psu gr 9405 or equivalent in as mentioned in appx b of particular specification 37 supply and fixing poly carbonatejunction box , weather and vermin proof of size 250x250x160 including provn of 4 nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators,including one no. mcb sp 6 amps for light control,drilling of holes.provn of suitable size of gi nuts, bolts, double washer and fi clamps ofsuitable sizefor taking connections and fixing on lt steel tubular poles complete with locking arrangement complete all as specified and directed. 38 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-(main ltp no-01 ) 39 incoming :-(a) mccb 4 pole 320 amp thermal magnetic protection type, 36kamake : legrand, cat no - 4220-06, dpx3 630- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc.(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100outgoing :-(a) mccb 3 pole 160amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4200-87, dpx 160- 01 nob) mccb 3 pole 200amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4202-08, dpx 250- 01 no (c) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(d) analog time switch, make- legrand, cat no 4127-80 for sl control 40 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -4. 41 incoming:- (a) mccb 4 pole 160 amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4200-57, dpx 160- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going:- (a) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 02 no (single offr accn + ltp - 08)(b) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 02 no ( servant qtr + sl)(c) mccb 3 pole 125 a thermal magnetic protection type, 25 ka dpx3 160, legrand, cat no 4200-06 - 01 (offr mess)(d) mcb dp 16amp - 01 no ( garage)(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(f) analog time switch, make- legrand, cat no 4127-80 for sl control 42 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp - 8incoming(a) mccb 4 pole 63 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-13 - 01 no 43 (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 10 no 44 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -3. 45 incoming(a) mccb 4 pole 200 amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4202-18, dpx 250- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 100 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-45 - 01 no(ltp - 06)(b) mccb 3 pole 160 a thermal magnetic protection type, 25 ka dpx3 160, legrand, cat no 4200-47 - 01 (adm bldg)(c) mccb 3 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-02 - 02 no (saa stores + old guard house)(d) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 03 no(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider (f) analog time switch, make- legrand, cat no 4127-80 for sl control 46 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -6 47 incoming(a) mccb 4 pole 100 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-55 - 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out goingm(a) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 01 no (b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 05 no 48 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -7 49 incoming(a) mccb 4 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-53 - 01 no (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-02 - 02 no ( bch + mt office)(b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 13 no (garage) (c) mcb 3 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-55 - 02 no (car washing + longe wala gate) 50 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:- (main ltp no-02 ) 51 incoming (a) mccb 4 pole 400 amp thermal magnetic protection type, 36kamake : legrand, cat no - 4220-07, dpx3 630- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100outgoing (a) mccb 3 pole 200amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4202-08, dpx 250- 01 no(ltp -02)(b) mccb 3 pole 160amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4200-87, dpx 160- 01 no (ltp - 01)(c) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 01 no(ltp - 5)(d) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(e) analog time switch, make- legrand, cat no 4127-80 for sl control 52 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -1 53 incoming(a) mccb 4 pole 160amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4200-57, dpx3 160- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 01 no ( ltp -5)(b) mccb 3 pole 25 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-01 - 02 no ( fwc + ori )(c) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 02 no ( religious hall + unit shop)(d) mccb 3 pole 80 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-44 - 01 no ( trademen shop)(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider (f) analog time switch, make- legrand, cat no 4127-80 for sl control 54 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -5incoming(a) mccb 4 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-12 - 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100 55 out going(a) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 01 no ( drying & ironing)(b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 4 no (car shed - 01 no + scooter shed - 01 no + dhobi ghat - 02 nos) (c) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(d) analog time switch, make- legrand, cat no 4127-80 for sl control 56 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system 57 and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -2incoming(a) mccb 4 pole 200amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4202-18, dpx3 250- 01 no (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 25 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-41 - 02 no (s/l jco)(b) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 04 no ( s/l 01 jco + engr store + def store + old bldg)(c) mccb 3 pole 80 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-44 - 01 no ( jcos mess)(d) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 01 no (mi room)(e) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 4 nos (car shed - 01 no + scooter shed - 01 no + garage for amb - 01 no +car shed/scooter shed - 01 no ) (f) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(g) analog time switch, make- legrand, cat no 4127-80 for sl control 58 taking down old cable xlpe insulated ,screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor off sizes from existing site 59 dismentling street light bracket off sizes complete all as specified and directed 60 dismantling and taking down lt feeder pillar box off size complete all as specified and directed 61 dismantling and taking down outdoor distribution box off size complete all as specified and directed 62 dismantling and taking down transformers 160 kva to 500 kva and deposit to mes store yard or keeping in safe custody for re-installation complete all as specified and directed 63 parade ground of size 137 m x 91 m, footbal/hockey 02 nos, basketball courts 02 nos, volley ball courts 02 nos, hardstanding & badminton court 01 no (sch a part-x (synthetic floor / mat for basket ball & volley ball courts) m & l for antifungal, anti microbial and u/v resistant comprising of pvc wear resisting coat thickness of 3.5mm to 8mm over of fiber-glass reinforced layer with pvc foaming buffer layer of thickness 4.5mm for good performance in rebounding & absorbing shock complete all as specified and directed 64 refrigeration and cold water supply(sch a part -xiii)supply and fix refrigerator, electric driven (single phase),direct cool single door 5 star refrigeratorwith base drawer with smart inverter compressorcapacitynot less than 185 litrescomplete all as specified and directed 65 supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity not less than 2.0kva complete all as specified and directed 66 supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 cum per hour (or nearest size) steel body complete all as specified and directed 67 addn/altn of existing buildings & structures (b/r) : schedule a part -xvm & l for providing 5-7mm thick screed bed ofchemical adhresive of approved make for laying floor finishes i,e floor tile etc. complete all as specified and directed. 68 taking down existing water proofing roof treatment of any description cleaning the surface by hacking to received plaster complete all as specified and removing demolised material outside mod land. 69 s & f fibre reinforced uv resistant elastomeric liquid applied waterproofing & heat reflective coating with acrylic polymers and polyester/glass fibres after scraping and properly cleaning the surface to remove loose perticles with wire brushes complete or as directed water proofing treatment shall be in three coats over a coat of primer and as per manufacturers instructions complete all as specified and directed. 70 m & l for retrieving vegetation growth/plants from wall roofs, chajja upto double storey height incl taking out deep roots and pouring hcl acid and making good the distrubance surfaces with cm 1:4 incl all means required at site complete all as specified and directed 71 addn/altn of existing buildings & structures (e/m) : schedule a part -xvitaking down of existing unsv sub main wiring any size incl pvc/steel conduit complete and making good to disturbed surfaces complete all as specified and directed. 72 taking down of existing unsv dbs any size complete all as specified and directed 73 supply & fixing of mcbs, 10 ka rupturing capacity, is-8828 marked,dp 10 ampsand fixing in dbs complete all as specified and directed(note:- dbs shall be measured and paid separately in respective item) 74 all as per items no 63.00 butdp 20 amps 75 all as per items no no 63.00 but 4p 25 amps 76 all as per items no no 63.00 but sp 6 amps 77 all as per items no no 63.00 but sp 10 amps 78 all as per items no no 63.00 but sp 20 amps 79 demolition of buildings & sheds : schedule a part -xvii taking down carefully by carefully unscrewing serviceable/unserviceable dbs,any sizes 415 volt complete with bus bar and rails for easy mounting of mcbs complete with from boards and disconnecting from incoming and outgoing complete all as specified and directed 80 taking down sub main wiring of any sizes complete all as specified and directed 81 arbouriculture work laying of lawns including ploughing leveling breaking of clods manuring & removal of stones etc. (cost of manure or extra good earth to be paid separately) maintenance of lawns for 30 days more till the grass forms a thick lawns free from weeds & fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost. in rows 5 cms. apart in either direction 82 supply of different flower plants 900mm to 1500mm at site including loading / unloading & transportation etc.complete all as specified and directed 83 supply of different varieties of shrubs 600mm to 900mm at site including loading / unloading & transportation etc.complete all as specified and directed 84 supply of different varieties of climbers 900mm to 1500mm at site including loading / unloading & transportation etc.complete all as specified and directed 85 supply of different varieties of palms in polyethylene bags / earthen pots according to height growth & age of the plant at site including loading / unloading & transportation etc .complete all as specified and directed 86 supply & planting of shady plants (neem, peepal, goolar, jamun, imli or other specified) along including the following activities :-(a)preparation of soil including & removing of unwanted shrubs removal of stones & garbage.(b) supply of plant at site of two years of age & height more than 1.50mtr.(c)supply of dry manure (farm yard manure.(d)supply of insecticides.(e)digging of pits size 60x60x60 cms. 87 supply & planting of ornamental plants (kachnar, amaltas, gulmohar, arjun, jacranda etc. or other specified) along including the following activities :-(a)preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage.(b)supply of plant at site oftwo years of age & height more than 1.50mtr.(c)supply of dry manure (farm yard manure organic).(d)supply of insecticides.(e)digging of pits size 60x60x60 cms. including removal of stones, manu-ring application of insecticides & watering at least15 liter per plant after planting.(f)watering to plants.
  • View Tender
  • Document
  • Bid Support
6 Metals And Minerals
image image
State Government
TRN :48897888 |  16 May, 2025
Tender Value : 4.12 Crore
 Barbil - Odisha
Tender for engagement of an agency to carry out diamond core drilling works, core logging, collection of core samples and chemical analysis engagement of an agency to carry out diamond core drilling works, core logging, collection of core samples and chemical analysis
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : drilling boring
  • Rig Positioning Service Tenders ,
  • Borehole Work Tenders ,
  • Drill Site Tenders ,
  • Drilling Service Tenders ,
  • Coring Service Tenders ,
  • Core Drilling Tenders ,
  • Exploration Work Tenders ,
  • Drilling Mud Engineering Services Tenders ,
  • Test Drilling Work Tenders ,
  • Core Drilling Work Tenders

Get drilling boring Tender Alert...

373271

Related Searched Keywords : drilling boring

  • Acoustic Panels Tenders From Maharashtra
  • Railway Under Bridge Tenders From Delhi
  • Slab Flooring Tenders From West-Bengal
  • False Flooring Tenders From -Tamil-Nadu
  • Sewage Pipeline Tenders From Andhra-Pradesh
  • Furbishing Work Tenders From Gujarat
  • Stone Cladding Tenders From Karnataka
  • Drainage Tenders From Uttar-Pradesh
  • Civil Work Tenders From Rajasthan
  • Check Dam Tenders From Madhya-Pradesh

Read More


Tender Document

490972

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Compound Wall Tenders
  • Development Work Tenders
  • Railway Over Bridge Tenders
  • Wall Work Tenders
  • Underground Sewer Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App