Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Interlock Paver
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of interlock-paver Tenders

List of latest interlock-paver Tenders in Indian Tenders. Click on any interlock-paver Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for interlock-paver Tenders.

Advance Search
  • All-Tenders (209)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
51 Security Services
image image
Central Government/Public Sector
TRN :48280497 |  17 May, 2025
Tender Value : 4.14 Crore
 Leh - Ladakh
Tender for tender for provision of central mi room at nimu(job no 01/nimu stn/amwp/2023-24); 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 43 2 lump sum price worked out by the contractor for (site clearance, excavation & earth work)as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 44 3 lump sum price worked out by the contractor for (internal electrification)as listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 50 4 lump sum price worked out by the contractor for (internal water supply)as listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 52 5 lump sum price worked out by the contractor for (road, path & hardstanding)as listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 54 6 lump sum price worked out by the contractor for (sewage disposal)as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 55 7 lump sum price worked out by the contractor for (area drainage)as listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 56 8 lump sum price worked out by the contractor for (shed for dg set)as listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 58 9 lump sum price worked out by the contractor for (hot water supply)as listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 59 10 lump sum price worked out by the contractor for (external electrification)as listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 65 11 lump sum price worked out by the contractor for (external water suplay)as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 66 12 sch a part - xii (misc b/r & e/m items) (refer boq)note: this schedule is not pre-priced by mes and the rate indicated as rs 0.00 under col 5 signifies this fact only 13 internal electrifications&f double door three phase prewired distribution board vertical db vtpn 8 way with acrylic door made out of crca sheets 1.6 mm thick,phosphatised powder coated with copper bus bar 200 amps, 415 v,ip 43/ik09, earth stud, din rail, polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingmccb4 pole 63 amp rating repturing capacity 16 ka.(note:- single phase mcbs are to be measured and paid for seperately) 14 s&f led building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240v, ip 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long med grade gi pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith ms clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm pvc insulated 3 core wire complete all as directed and specified by engr-in-charge.note - cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 s&f new wall mounted fan of approved make and type complete all as specified and as directed. 16 s&f tv co-axial socket 1 module, complete all as specified and as directed. 17 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole mcb 20 amps 18 internal water supplys&f single piece vitreous china wash down water closet pan pedestal pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type b-0, as in repairs complete all as spd & directed complete all as specified and directed by engr-in charge.. 19 s&f cp grating including jointing to waste pipe fixed in cement concrete type b-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by engr-in charge. 20 s&f hand shower (health faucet ) with 8mm dia and 1 meter long cp flexible tube and wall hookcomplete all as specified make: cera, jaquar , marc & hindware as per sample and directed by engr -in charge 21 s&f soap dish (s/s), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by engr-in charge. 22 road, path & hard standingm&l for wet mix macadam (wmm) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of morth (ministry of road transport & highways) specification of road and bridge works 2013. manufactured in wmm plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 kn static weight and conslidating required gradient and camber. the finished surface tolerance to be as per table 900-1 of morth specification for road and bridge works 2013 complete all as specified and directed by engr-in-charge. 23 m&l for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to bs 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 m&l for rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m-30 design mix in walls , base slab , baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 m&l for soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonary in cm, rcc cover slab in m25/ sfrc cover, interconnecting pipes of rcc/dwc complete filled with brick bats of size 3m dia and 3 m depth. 26 s&f pvc junction boxes ip 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 nos mcb sp 2.5 amp & 4 way industrial connector including clamp made out of ms flat 30x5mm connection from junction box to street light fitting with three single core pvc insulated, pvc sheathed wire 2.5 sqmm copper & pvc conduit 20 mm dia complete all as specified and directed by engr-in-charge. 27 excavation in trenches by cutting of road crossing/pcc hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by engr-in-charge. 28 s&fht/lt ms cable route indicator 4 dia fixed with two nos of nut, bolt and washers and provision of pcc 1 : 4 : 8 type d-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by engr-in-charge. 29 supply, installation, testing and commissinoning lt panel board suitable for working on 3 phase ,4 wire ,415 volts, ac ,50hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick crca sheetduly powder coated and shall be cpri approved and as approved by ge. the panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, copper bus bar duly covered with heat shrink sleeves colour coaded duly fixed ondmc/smc insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing mccbs shall have extended bus bar links and mounted on 50x50x5mm sizems angle iron frame duly painted including pcc 1:2:4 type b1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of age (i) nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) mccb 400 amps, fp, 36 ka, 415 volts, 50hz - 01 no (i/c)(b) mccb 200 amps, fp, 25 ka, 415 volts, 50hz - 02 no ( chs)(c) mccb 125 amps, fp, 18 ka, 415 volts, 50hz - 04 nos (apfc, tpn db -02, spare )(d) mcb spn 40 amps, 10 ka, 220 volts, 50hz - 03 nos (garage,street light, spare-1)(e) on load chengeover 630 amps 4 pole -01 no (f)digital voltmeter, with vss - 01set(g) digital ammeter, with cts & ass - 01 set(h) led phase indication lamps ryb - 01 set(j)single phase rotary automatic light controller nature switch with voltage range 120-440v,ac,20 amps,ip-65,50hz-01 nos(k) copper bus bar tpn 600 amps rating - 01 set 31 labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and gi tubing in soft/loose soil complete all as specified. 32 m&lfor cutting existing gi pipes and insertion of new tee branches of suitable size to take branch connection of 50mm dia pp-r.note : suitable size of tee branch is deemed to be included in the quoted rate. 33 construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingpcc in foundation of the mixture (1:4:8) d-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) ms steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed ms work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in pcc with two coats of black bituminuos paint andall other relevant work complete . 34 m&l for providing tracer/anti freezing cable required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (central heating system)electric hot water generator : supply, installation, testing and commissioning ofpackage type electric hot water generator constructed out of ms sheet having top open-able cover for easy access and removal of heaters. the hwg shall be suitable for indoor mounting. the generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22g aluminium cladding sheet. the generator shall have electrical capacity of 50 kw. the heater shall be electrical resistance type, copper tube with chromium plating. the generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. the generator shall be suitable for 3 phase, 415+ 10% volts, 50 hz. ac supply. the generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 notes:- (i) allneccassary accessories required for the proper fucntioning of hot water genearator are included in price.(ii) the prices should include lifting, shifting and positioning of units at site.(iii) hot water genearator installation to done as per manufacturer recommendation with all installation requirements i.e foundation, vibration isolator,insulationetc as recommended by manufacturer for the ambient temperature of site. odu installation is included in odu price which includes the civil struture, mechanical structureetc as recommended bymanufacturer.(iv) the contractor/oem will shall submit the hot water generator capacity/burner capacity conforming to relevant is code(v) oem should submit the installation and maintenance schedule/ manual for the boiler. 37 glycol circulation centrifugal pumps: supply, installation, testing & commissioning of pn16 ratedaxial split coupled vertical inline water pump set with ci casing, bronze impeller, ss shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with suitable hp, tefc squirrel cage induction motor with ie3 type class f insulation, motor shall be rating of ip 55, operating on 415 ±10% volts, 3 phase, 50hz ac supply. the external flush line must be used for the purpose of heat dissipation from the mechanical seal.pumps with performance characteristics as given below:the internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 degree celcius to 120 degree celcius. vendor shall be provide antivibration arrangement for pumps . 38 the scope also shall include following below mentioned:(i) electrical by pass starter for pump setas recommended by oem. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) pressure gauges 150 mm dia -03 nos (iv) mounting frame with antivibration pads (in case pumps are inline, anti vibration system shall be as per manufacturers recommendation) (v) rcc/cement concrete foundation for the pump unit. (in case pumps are inline, foundation shall be as per manufacturers recommendation).pump capacity are as under:capacityand pump headnot less than flow 25 usgpm , head 20 mtr (refernce model no. : armstrong : series 4300 - 40-150 - 2p - 1.5 kw) each including the triple duty valve and end suction guide. 39 expansion tank and pressurisation unit:supply, installation, testing and commissioning of insulated pressurised closed water expansion tank suitable for total volume ofglycol - water solution, circuit along with necessary accessories such as along with necessary accessories such as 2 nos pumps (1working +1standby) with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. the tank shall be pre-charged. expansion tank shall be with replaceable heavy duty butyl rubber bladder. the tankconnections should be as per oem recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.the tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. the tank must be constructed in accordance with is-standard 2825-1969 (withlates revision)and rated at pn 16 . the complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.the tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelip55 control panel, pressure transmitter, interconnecting piping & wiring. (tank capacity 500 ltrs). hot glycol - water closed vessel pressurized expansion tank as described above shall be duly insulated with 50 mm thick puf/nitrile rubber insulating material or equivalent u valueinsulating material and cladded with aluminium sheet (20g). electrical by pass starter for pump setas recommended by oem. 40 expansion tank of 500 lts capacity 41 pressurization unit: for pump set -03 nos with control panel and accessories. 42 make up tank: supply, installation, testing and commissioning of factory made make up water tank, rectangular/circular shape, of 4 mm thick ms sheet (is 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of ms and vent with flame arrestor. tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above ffl. service platform shall be provided as per recommendations of oem. the tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. extra high level and extra low level alarm shall be provided. tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.make up water tank as describedabove should beduly insulated with 50 mm thick puf/nitrile rubber insulating material and cladded with aluminium sheet (20g). 43 supply, installation, testing and commissioning ofsteel plate radiator( wall mounted) confirming en- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°c, complete with top grill side cover as standard along with inlet ,outlet valve, air purge valve andwith threaded plug, flow regulator as per oem.the below desired capacity should be calculated at altitude of 3600 mts above sea level. capacity calculation sheet to be provided to engineer in charge. the below mentioned capacity is at inlet temp: 75 degree celcius , outlet temp: 65 degree celcius. referemcwe model series. 44 1.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 45 2.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 46 3.5 kw,type: 33- dkek, length is 1600 mm and height is 600 mm of radiator. 47 5 kw,type: 33- dkek, length is 1600 mm and height is 900 mm of radiator. 48 5 kw,type: 33- dkek, length is 2000 mm and height is 600 mm of radiator 49 m & l for pre-insulated ms pipe,class c havingminimum thicknes of puf insulation as mentioned below and of density 36 kg/cum and 26 gauge al cladding complete suitable for above ground as per sizes shown.the pipes should be insulated with closed cell puf of density 36±2 kg/cum of below mentioned thickness. the pipe should be workable in the temp. range of-50 degree celciusto120 degreec celcius. note:-the pipes size 150mm & below shall be m.s. ‘c’ class as per is : 1239 50 80 mm with 36 mm puf thicknes and 26 gauge al cladding. 51 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 52 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 53 40 mm with 36 mm puf thicknes and 26 gauge al cladding. 54 20 mm with 36 mm puf thicknes and 26 gauge al cladding. 55 buried under ground/exposed to ambient:80 mm with 50 mm puf thicknes and hdpe cladding, 26 gauge al cladding. 56 cabel tray :-supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ground/wall with m.s. suspenders as per is code including bolts & nuts, painting suspenders etc. as required of size 150 mm width x 50 mm depth x 1.6 mm thickness 57 supplying, fixing, testing and commissioning of following diameter valves (pn-16 rating) (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), strainers (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), gauges etc for condenser water circulation as per specifications. insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified. butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets.butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets. 58 80 mm dia butterfly valve 59 65 mm dia butterfly valve 60 50 mm dia butterfly valve 61 supplying, fixing, testing and commissioning of y-strainer (insulated valves) of ductile ci body flanged ends with stainless steel strainer forhot water circulation including insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified of size 50 mm dia y strainer. 62 supplying, fixing, testing and commissioning of non - return valve (insulated valves) with duel plate of ci body ss plates vulcanized nbr seal flanged end & pn 16 pressure rating forhot water circulation includinginsulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as sepcified of size 50 mm dia nrv. 63 supplying, fixing, testing and commissioning of automatic air purge valves forhot water circulation headeras specified of size automtic air purge valve 20 mm dia. 64 supplying, fixing, testing and commissioning of air separator compleate allas specified of size 50 mm dia. 65 supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and ss tubing, socket.range (0-50) / (0-100) as required by engineer in charge. 66 supplying, fixing, testing and commissioning of mercury in glass industrial thermometer in ss-304 casing with 0.5 c least count, range 0-50 c. brass oil filled thermowell of 1/2 size as required by engineer in charge. 67 electrical distribution panel supply, installation, commissioning and testing of factory made, chs plant, indoor type made out of crca sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with ms angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 phase4 wire, 415 volts, 50 hz, ac supply system, floor mounted and grounting the legs of panel in pcc foundation 1:4:8 complete as all directed suitable for and including the following :- 68 incomers(i) bus bar tpn al extensible type main bus bars of minimum of 600 a capacity (as per capacity of corresponding incoming / bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c smc bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50ka .(ii)mccb 400 amps, 415 volt, 36 ka, 4 pole,microprocessor release- 01 no for incoming (extended rotary operating handle, phase spreader links and phase barriers ) make: legrand/schenider/simensoutgoings(i) 3nos- 125a ,25 ka tpnmccb/acbwith microprocessor release (3# hot water generator)(ii) mcb 10 amp,tpn,10ka, c curve - 06, 3 nos for pumps , 2 nos for pumps ,01 nos for glycol transfer pump(iii) led phase indication lamps (01 set) with 2amp back up mcb,breaker on/off indicating light with 2a mcb, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 set (iv) digital ammeter with in built ass,metering c.t.scast resin type, 15va, and accuracy class-1of 800/5a for measuring current in each phase - 01 set.(v) all accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per manufacturers recommendations all as directed by engnr-in-charge.note : contractor will submit the drawing for approval of panel to ge before execution. 69 lt cables : supply & laying/ fixing of following size xlpe insulated and pvc sheathed copper conductor armoured cable/unarmoured as required of 1.1 kv grade complete as require (isi marked) (in ground/in pipe/in duct/on surface/on cable tray) 70 3.5 core x 70 sq.mm. (electric hot water generator) 71 4.0 core x 10 sq.mm. (pump) and (pressurization unit) 72 2 core x 10 sq.mm. (pump) 73 2 core x 6 sq.mm (pressurization unit) 74 earthing complete with copperearth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long gi pipe connected to main controlboard and gi pipe light grade 20mm bore for watering and including funnel, wire mesh, rcc pit cover 50mm thick and pcc chamber pit with pcc 1:2:4 type c2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate no 3 of ssr part-i 2009 complete all as specified & directed by engr-in-charge 75 s&f rubber matting conforming to is-15652-2006 complete as required. of size2m x 1m x 25 mm 76 glycol - water solutionsupplying of ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.note;- (i) the glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. the glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 degree celcius (ii) first charge of glycol is included in the quoted rate. first charge include charge in chs pipe linestorage tank. (glycol 45 % ,water 55 %) 77 for chs 78 supply of gycol for running of plant for 12 months 79 glycol circulating pump: supply, erection, testing and commissioning oftransfer pumps for the capacity of 5 lpm 5 meter head for glycol fluidtransfer with base frame foundation, bolts coupling coupling guard,tefc, (oem design hp for the required flowand head ) andother accessories for proper function of the pump. 80 oxygen gas manhold : supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, nrv and essab make 10x14 regulator complete all as specified and directed by engr in charge . 81 supply , installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by engr in charge . 82 supply , installation , testing and commission automatic control panel with analog display 02 for oxygen complete all as specified and directed by engr in charge. 83 s&f of copper tubing of size 15 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 84 s&f of copper tubing of size 12 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 85 s&f bs type gas outle with probe for oxygen for medical compleate all as specified and directed by engr in charge 86 s&f 1/2 brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by engr in charge. 87 s&f bpc flow meter (0-15 lpm) including humidfire bottle complete all as specified and directed by engr in charge . 88 s&f 3/8 brass ball valveincluding all fittings for complete all as specified and directed by engr in charge. 89 stand by dg set : supply,install, test and commissioning of silent diesel engine generating set 415 volts, 3 phase, 4 wireengine as per is08528 conforming to cpcb norms iv, and alternator as per is08528 of capacity 400 kva at ntp with control panel having meters, sound proof canopy etc with foundation (as per oem design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- ac generator should be suitable for ambient conditions at nimu leh area. 90 (a) alternator : standard design alternator rated at 400 kva (320kw)net output at power factor 0.8, ac, 3 phase 4 wire, 415 v, 50 cycles/second, 1500 rpm self excited, self regulated, screen protected, drip proof ip 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (b)diesel engine : vertical diesel engine of suitable capacity, water cooled, closed circuit as per bs-649 or is-1002 direct injection type turbo charged, electric starting system having rated speed 1500 rpm. the dg set shall be capable for running with 10% over loading for 01 hour in every 12 hours as perbs-5514/bs-649. engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following specifications.(a) fly wheel with housing (i) common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) cooling system (i) radiator with fan & belts & guard, rubber hoses and thermostat. (ii) cooling water pump centrifugal type . 91 (c) governer : electronic governer (d) electric starting system : electric self starter , 24 volts dc(12 volt, 150 ah battery 2 nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2x12 volt 150 ah capacity. (e) generator monitoring panel : comprising of following :- (i) microprocessor based genset controller for metering, monitoring, governing and protection. (ii) engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) accessories:avm pads built or separately mounted to manufacturer base frames. (g) coupling arrangements: fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) exhaust system : should have equipped with emission control device as per latest govt norms. silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) fuel tank: daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (c)acoustic enclosure : all as per cpcb norms iv and oem of dg sets design.(d)amf panel : supply, install, testing and commissioning of amf panel outdoor type, cubical body,dust and vermin proofmade up of crca sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to ip 45 with front and rear opening with louvers andmounted on floor with pcc pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) microprocessor based panel -01 no(ii) power contactor heavy duty suitable for generator and mains (iii) over load relay for genset (iv) suitable rating isolating switch mccb for both dg & main supply.(v) multi functioning meter to indicate voltage, current, frequency, p f, kw & kwh etc (vi) emergency stop push button.(vii)set of indicaters : - (a)low lube oil pressure (b) dg set over load(viii) push button to start, stop (ix) mode selector switch i.e auto/manual/test/ off.(x) set of instrument fuse (xi)set of aluminium bus bar of 600 amps capacity 3 ph, 4 wire system (xii) automatic battery charging unit with dc voltmeter, ammeter and selector switch for trickle/ boost charging.(xiii) by pass arrangement of main supply when amf circuit fail due to any fault with provision of suitable rating change overs and switches. 93 the following items are deemed to be included in the rate quoted for all dg sets:- (i) dhpp for testing purpose shall be supplied by the contractor without any extra cost to department. (ii)the contractor shall arrange for artificial load (water load/electrical load) for testing for final testing of dg set at site and the cost is deemed to be including in above offer. (iii) testing of sound level should carried out at the site in presence of engineer-in-charge(iv) one set of latest spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) all civil works including foundation for dgset as per manufacturers drawing/ specification, foundation for amf panel shall deemed to be included in the quoted rate.(vi) the rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
  • View Tender
  • Document
  • Bid Support
52 Water Supply And Drainage
image image
State Government
TRN :49052578 |  14 May, 2025
Tender Value : 39.34 Lacs
 Mamdot - Punjab
Tender for agumentation of water supply scheme for village chak kande shah panja singh wala, block mamdot district ferozepur(pb.) (under head pidb/4215) name of work :- construction of one no. rcc ohsr 25000 ltrs capacity with sill level not less than 15.50 mtr. and height upto fsl 17.20 mtr from formation level, disinfection unit electrically based and construction of pump chamber 3.05 x 3.70m including gravil pit and construction of ihhl ,complete in all respects ,& providing, laying, cutting, jointing & testing of pvc pipe 10 kg/cm2 for rising main & 6kg/cm2 for distribution. including cost of excavation, dismantling & relaying of dry brick on edge paving, dismantling of matalled road, cc flooring, house hold water connection, pumping machinery, solar panel, development of water works site i.e. corner pillars, barbed wire fencing, fencing poles, d-hooks, gate pillars, foot path, sign board, including carriage of material complete in all respect. (completion period 9 month)
  • View Tender
  • Document
  • Bid Support
53 Civil Work
image image
State Government
TRN :49053588 |  23 May, 2025
Tender Value : 16.45 Lacs
 Villupuram - Tamil Nadu
Tender for tender for construction of angnawadi building at vadughapoondiin melmalayaur block; 1 construction of anganwadi building@ mettuvailamur in melvailamur panchayat 2 earth work excavation for foundation in all classes of soils and sub soil to full depthexcept in hard rock requiring blasting but inclusive of shoring struttingif required forthe sides of foundation. 3 supplying and filling in foundation and basement with good sand in layers not more 15 cm thick including ramming, watering and compacting etc.complete complying to standard specification 4 cement concrete 1:4:8 mix using 40 mm hbg metal for foundaion including watering wherever necessary and laid in layers of not more than 15cm thick. compacting etc., complete complying with standard specifications and as directed. 5 brick work in cm 1:5 mix using country bricks ground moulded of size 23 x 11 x 7 cm for the following including curing etc., complete complying with standard specifications. 6 supplying and fabricating and placing in position ms steel or ribbed for steel for all reinforced cement concrete works as per the design given including cost of steel and blinding wire all floors etc., complete complying with standard specification. 7 supplying and erection centering for sides and soffiots including necessaary supports and strutting as directed by the departmental officers. rate for 10m2 for the following items (rcc floor slab, roff slab, rectangular / square, tee/ ell beams, lintels, 8 bgl 9 agl 10 reinforced cement concrete 1; 11/2;3 using 20mm iss hbg metal including the cost and conveyance of all meterials and cost of all labour charges etc complete 11 plastering cm 1;4 -20mm thick including the cost and conveyance of all materials and cost of all labour charges etc., complete. 12 finishing the top of roof with one course of solar reflective tiles cm laid incement mortor 1 : 3 mix and pointingwith the same mortor mixed with water proof compoundincluding cost conveyance of all materials and labour charges etc complete 13 providing scratch proof ceramic tiles including cost and conveyance of all materials to site and all labour charges for mixing, laying and curing etc, complete. 14 dadooing the walls with glazed tiles including the cost and conveyance of all materials and cost of all labour charges etc., complete 15 flooring using 2 x 2 vitrified tiles approved and pointing with same colourincluding cost and conveyance of all materials to site and all labour charges etc complete 16 granolithic flooring using 10 - 12mm chips including cost and conveyance of all materials to site and all labour charges etc complete 17 ceiling plastering with cement mortar 1:3 mixto 10 mm thick for r.c.c. items including cost and conveyance of all materials to site and all labour charges etc complete 18 plastering cm 1;5 -12mm thick including the cost and conveyance of all materials and cost of all labour charges etc., complete. 19 distempering two coat using oil bound distemper including cost of distemper and labour charges, etc, complete. 20 painting two coat approved cement paint over the plastered surface including cost and all other charges etc., 21 painting two coat enamel paint over the new iron work surface including cost and all other charges etc., 22 supply of steel doors and windows 23 door0.90x2.10 m 24 door0.75x1.20 m 25 door1.10 x 2.10 m 26 window1.20 x 1.300 m 27 vernilator 0.90x0.45 28 supply and fixing of cuddappa slab including cost and conveyance of cuddappa slab and labour charges for fixing etc, complete. 29 cost and supply of rcc jolley 30 provision for rain water arrangements 31 supply and fixing baby watercloset with p- trap 32 supply and fixing european water closet with all accesoories 33 providing following electrification items 34 provision for labour charges fixing door and window 35 provision for sanitary arrangement 36 provision for rain water structure 37 citizen information board 38 gst amount for providing service to government contract works for the above construction works. { gst amount is the total gst amount for total overall quoted amount above this row in column bb for all works in this package}
  • View Tender
  • Document
  • Bid Support
54 Civil Work
image image
State Government
TRN :49053791 |  14 May, 2025
Tender Value : 1.75 Lacs
 Kallakurichi - Tamil Nadu
Tender for tender for providing of paver block keel street length of the road 30 in meter width of the road 3.00 in meter. at kalliparai habitation in kilakadu panchayat.; 1 providing of paver blockkeel street length of the road 30 in meter width of the road 3.00 in meter. at kalliparai habitation in kilakadupanchayat 2 cc pavementearthwork excavation and depositing on bank with initial lead and liftin all type of soil except hard rock requiring blasting as per ss 20 b for kerb wall foundation 3 cost and labour for centering works including all cost andconveyance and all labour charge etc,complete 4 plain cement concrete1:4:8mix using 40mm hbg metal including all cost andconveyance and all labour charge etc,complete 5 plaincement concrete 1:2:4 mix 20mm hbg iss metal including all cost andconveyance and all labour charge etc , complete 6 construction of granular sub base by providing well graded material (25 mm to 4.75 mm irc hbg metal @ 65 %,4.75 to 2.36mm irc hbg metal@20%&2.36 mm below irc hbg metal @15%) including cost and conveyance and materials and labour charges etc,..completed. 7 flooring with paver laid with 80mm thick including cost and conveyance of all materials to site and all labour charges for mixing,laying and curing etc complete 8 provision for name board 9 provision for photographic charges
  • View Tender
  • Document
  • Bid Support
55 Construction
image image
State Government
TRN :49053871 |  14 May, 2025
Tender Value : 0
 Anantnag - Jammu And Kashmir
Tender for stage contract for sub division anantnag.- stage contract anantnag sub division. 2 engagements of jcbfor execuation of works of various natures 3 surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -all kinds of soil 4 earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed,( all kinds of soil) 5 earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by engineer-in-charge. all kinds of soil : 6 earth work in excavation by manualmeans in trenches for foundations, drains, pipes, cables etc .upto required depth ) and for shafts, wells, cesspits including dressing of sides and ramming of bottoms , including getting out excavated earth and disposal of surplus excavated earth as directed,( all kinds of soil) 7 supply and filling of rbm of specified size including spreading, watering, ramming, compacting with prr of 8 to 10 tonne capacity and including carriage of the same from approved source upto site of work complete 8 felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. 9 beyond 30 cm girth upto and including 60 cm girth. 10 beyond 60 cm girth upto and including 120 cm girth. 11 beyond 120 cm girth upto and including 240 cm girth. 12 banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soi 13 supply and filling of khak bajri including spreading, watering, ramming, compacting with prr of 8 to 10 tonne capacityincluding carriage of the same from approved source upto site of work complete( for berm) 14 providing / laying of rcc pipes in proper position/ grade including cutting of road surface upto required depth, providing requisite cushion including carriage ofall materials and pipesupto site ofwork complete. 15 10 16 12 17 14 18 16 19 20 20 24 21 32 22 36 23 40 24 48 25 providing / laying of ms pipes in proper position/ grade including cutting of road surface upto required depth, providing requisite cushion including carriage ofall materials and pipesupto site ofwork complete. 26 6 27 8 28 10 29 12 30 scarifying the existing bituminous road surface to a depth of 50mm and disposal of scarified material within all lifts and lead upto 1 km (by mechanical means). 31 scarifying metalled (water-bound) road surface including disposal of rubbish lead upto 50m and consolidation of the aggregate received from scarifying with power road roller of 8 to 10 tonne capacity. 32 providing and laying water bound macadam base course with quarry crushed stone aggregate 90 to 45mm size, stone screening 13.20mm size and binding material as per morth specification including screening, sorting, spreading to template and consolidation with prr of 8 to 10 tonne capacity including carriageofquarry crushedstone aggrregateand stone screeing, stone dustfrom approved soucrce upto site of wotk complete(finished work to be measured) 100mm compacted thickness 33 providing and laying water bound macadam base course with quarry crushed stone aggregate 63 to 45mm size, stone screening 13.20mm size and binding material as per morth specification including screening, sorting, spreading to template and consolidation with prr of 8 to 10 tonne capacity including carriageofquarry crushedstone aggrregateand stone screeing, stone dustfrom approved soucrce upto site of wotk complete(finished work to be measured) 75mm compacted thickness 34 providing and laying water bound macadam base course with quarry crushed stone aggregate 53 to 22.4mm size, stone screening 11.20mm size and binding material as per morth specification including screening, sorting, spreading to template and consolidation with prr of 8 to 10 tonne capacity including carriageofquarry crushedstone aggrregateand stone screeing, stone dustfrom approved soucrce upto site of wotk complete(finished work to be measured) 75mm compacted thickness 35 providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (wmm) specification including premixing the material with water at omc in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of engineer-in-charge 36 providing and applying tack coat using hot straight run bitumen of grade –vg-10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. on bitumen surface @ 0.50 kg/sqm 37 providing and applying tack coat using hot straight run bitumen of grade –vg-10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. on w.b.m. @ 0.75 kg/sqm 38 providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of engineer-in-charge. 50 to 100 mm average compacted thickness with bitumen of grade vg-10 @ 3.5% (percentage by weight of total mix) 39 providing and laying semi- dense bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of engineer-in-charge. 25 mm compacted thickness with bitumen of grade vg 10 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of aggregate) 40 providing and laying dense graded bituminous macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of engineer-in-charge. 16.62.1 50 to 100 mm average compacted thickness with bitumen of grade vg-30 @5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of aggregate) prepared in batch type hot mix plant of 100-120 tph capacity. 16.62.2 50 to 100 mm average compacted thickness with bitumen of grade vg-30 @5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of aggregate) prepared in drum type hot mix plant of 60-90 tph capacity. 41 providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade vg-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road all complete. 42 providing and laying of stone soling, hand packed, including carriage of same from approved source upto site of work complete. 43 providing and laying in position cement concrete in1 : 4 : 8 (1 cement :4 coarse sand : 8 graded crushed stone aggregate, 40mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. 44 providing and laying in position cement concrete in1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate, 40mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. 45 providing and laying in position cement concrete in1 : 2 : 4 (1 cement :2 coarse sand : 4 graded crushed stone aggregate, 20mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. 46 providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. but including carriage of all materials from approved sources up to site of work complete.all works upto plinth level (1: 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 47 providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. but including carriage of all materials from approved sources up to site of work complete.all works upto plinth level (1 : 2 : 4 (1 cement :2 coarse sand : 4 graded crushed stone aggregate, 20mm nominal size)) 48 reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.but including carriage of all materials from approved sources up to site of work complete. (1: 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 49 reinforcement for rcc work including straightening cutting, bending, placing in position and binding all complete (thermo mechanically treated bars) including all carriages complete. fe-500 d or more 50 providing / fixing of necessary farm work / shuttering including strutting, propping etc and removal of same complete 51 foundations, footings, bases for columns 52 return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc. 53 suspended floors, roofings, landings, balcones and access plateform 54 50mm thick cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished wit a floating coat of neat cement including carriage of all materials from approved sources upto site of work complete 55 40mm thick cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished wit a floating coat of neat cement including carriage of all materials from approved sources upto site of work complete 56 25mm thick cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished wit a floating coat of neat cement including carriage of all materials from approved sources upto site of work complete 57 12mm cement plaster of mix 1:4 (1cement: 4 fine sand) including all carriages complete. 58 12mm cement plaster of mix 1:6 (1cement: 6 fine sand) including all carriages complete. 59 15mm cement plaster of mix 1:4 (1cement: 4 fine sand) including all carriages complete. 60 15mm cement plaster of mix 1:6 (1cement: 6 fine sand) including all carriages complete. 61 dry random rubble masonry in 100 x100mm mesh size g.i wire crate made of 5mm dia g.i wire using bond stones ncluding wrapping /tightening of wire crate and binding wire crates after stone work including cost of all material involed (crates and stones) and carriage of same upto site work complete (quarry stones) 62 random rubble masonry with hard stone (quarry) in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarsesand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of all materials from approved sources up to site of work complete. 63 engagement of labour /masdoor for one day 64 engagement of skilled labour with all machinary like cutters , axe etc for purning of the trees 65 pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 66 removal of unhygienic materials (so classified by the site engineer) from designated sites and its disposal as per directions, all inclusive 67 clearance of slipsdisposal lead upto 50 m and lift upto 1.5 m. 68 in ordinary soils disposal lead upto 50 m and lift upto 1.5 m. 69 in soils; mixed with moorum/kankar/shingle/boulders; disposal lead upto 50 m and lift upto 1.5 m. 70 in soils; mixed with decomposed rocks; by blasting or any other means 71 providing and applying 2.5mm thick road marking strips (retro-reflective) of specified shade/colour using hot thermoplastic material by fully/semiautomatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreignmaterial etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 72 white washing with lime to give an even shade :old work (two or more coats) 73 white washing with lime to give an even shade :old work (one or more coats) 74 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work 75 painting road surface marking with adequate no. of coats to give uniform finish with read mixed road marking paint conforming to is: 164, on bituminous surface in white/yellow shade including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.old work ( one or more coats) 76 providing and laying at or near ground level factory made kerb stone of m-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-incharge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 77 manufacturing supplying and fixing retro reflective sign boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type-iv of astm-d-4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per irc : 67-2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of astm-d-4956-01 and fixing the same with suitable sized aluminum alloy rivets @ 20cm c/c to back support frame of m.s. angle iron of size 25x25x3mm along with theft resistant measures mounted and fixed with 2 nos. m.s. angles of size 35x35x5mm to a vertical post made upto m.s. tee section ismt 50x50x6mm welded with 16.0 (road work) 224 base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angle flats, providing and fixing m.s. message plate of required size steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical m.s.-tee support to be painted in black and white colours). backside of aluminum sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coats including all leads and lifts etc. complete as per drawing, specification and direction of engineer-in-charge. 16.66.1 mandatory/regulatory sign boards of 900 mm diameter with part as length of 3750 mm. 78 structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete 79 structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. welded 80 supply and filling of rbm of specified grade including spreading, watering, ramming, compacting with prr of 8 to 10 tonne capacity material availabe at site
  • View Tender
  • Document
  • Bid Support
56 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
57 Security Services
image image
Central Government/Public Sector
TRN :49054152 |  20 May, 2025
Tender Value : 77.92 Lacs
 Abohar - Punjab
Tender for tender for special repair to building no p-137 at mil stn abohar; 1 demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise complete all as specified and directed by engr-in-charge. 2 material & labour for 75mm thick pcc 1:3:6, type c1, using 20mm graded stone aggregate as in hard standing ,plinth protection/path etc,laid in suitable panels n.exc 3.00 m length finished even and smooth without using extra cement with contraction(dummy)joints 65mm deepx10mm wide joints filledwithbituminous sealing compound of grade ‘a’/bitumen mastic filler/sealant complete all as specified and directed by engr-in-charge. 3 dismantling brick tiles in floor or in roofs laid dry and pointed in any cement mortar complete all as specified and directed. 4 demolition of mud in roofs any thickness incl plastering and leeping 5 m & l for 40mm thick cement concrete type b0 1:2:4, (using 12.5mm graded stone aggregate) as in, surface finished even and smooth without using extra cement 6 m & l 10mm thick rendering in cement mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by engr-in-charge. 7 m&l for preparation of roof top surfaces,providing and applying uv stable single component smart care damp proof ultra is a fiber reinforced elastomeric liquied appplied water proofing membrane formulated with pu hybrid polymers and reinforcing acrylics fibres and having sri of 106 on top of concrete roof surface in three coats including self primer at ratio pf dampproof and water 3:1 and coverage @ 1 ltr/10 sqm with a thickness of 650 micron. note : (i) 6 hrs interval between two coats will be maintained. (ii)the treatment shall be carried out by authorised applicator approved by ge as per the manufacturer(iii)payment will be made after providing warrnty certificate from the company. 8 m&l 40mm thick brick tiles laid/beded including screed bed 15mm thick in cement mortar (1:6) on existing lime concrete sufaces of roof,joints grouted flush in cement mortar (1:3) mixed with liquid wpc @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of mes sch part-i (2009) complete all as specified and directed by engr-in-charge. 9 m&l 40mm thick brick tiles( old serviceable tiles obtained from demolition/desmantled item shall be reused) laid/beded including screed bed 15mm thick in cement mortar (1:6) on existing lime concrete sufaces of roof,joints grouted flush in cement mortar (1:3) mixed with liquid wpc @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of mes sch part-i (2009) complete all as specified and directed by engr-in-charge. 10 dismantlingof reinforced cement concrete by chiseling (without affecting other portion) of any description and in any position as in roofs, floors (other than ground floor), beams, landing, chajjas and similar suspended work. 11 m&l reinforced cement concrete 1:1 1/2:3 (nominal mix) using 20mm graded stone aggregate as in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately). 12 m & l mild steel tmt bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with ms wire (annealed) not less than 0.90mm dia all as in column, beam etc . 13 m&l for form work to soffits of suspended slabs such as roof slabs,floor slabs,landings and similar work not exc.200 mm thick(horizontal or sloping) rough finish surface of concrete flat all as specified and directed. 14 m&l for precast reinforced cement concrete (1:2:4) type b1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole set in cm (1:6).note :- cost of form work is deemed to be inclusive of unit rate quoted by the contractor & reinforcementshall be measured & paid separately.) 15 taking down chowkatsor frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified. 16 taking down chowkatswith shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) 17 taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and refixing in same opening after necessary easing, adjustments, minor repairs, oiling, adjustment with cutting or fixing plain fillets/planks made from second class hard wood etc to remove gap between floor and shutter complete all as specified and as directed by engineer-in- charge. 18 taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm eachcomplete all as specified and as directed by engineer-in- charge. 19 s&f factory made single extruded wpc (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 45 x 70 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed ss screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 n (face) & 1100 n (edge), minimum compressive strength of 58 n/mm2, modules ofelasticity 900 n/mm2and resistance to spread of flame of class a category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with ms hold fast/ lugs/ss dash fasteners of required dia and length complete as per direction of engineer-in-charge. (m.s. hold fast/ lugs or ss dash fasteners shall be paid for separately). note :- for wpc solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made all as specified and directed . 20 providing and fixing factory made single extruded wpc (wood polymer composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 n (face) & 900 n (edge), minimum compressive strength 50 n/mm2, modulus of elasticity 850 n/mm2 and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant. wpc to be laminated with pvc foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk s.s screws, all as per direction of engineer- in- charge including supply and fixing following items : (a) stainless steel (304 grade) finished butt hinges 100mm - 4 nos. per leaf (b) stainless steel (304 grade) finished square tower bolt 150 mm long - 2nos per leaf (c) stainless steel (304 grade) finished handles 150 mm - 2 nos. per leaf 21 supply and fixingfactory made pressed steel frames of size 125 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , includingbutt hinges suitable nos as directed for each leaf, complete all as specified and as directed by engineer-in- charge. 22 supply and fixingfactory made pressed steel frames of size 105 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , including butt hinges suitable nos as directed for each leaf, complete all as specified and as directed by engineer-in- charge. 23 m&l cement concrete 1:3:6 type c-1 using 20mm graded stone aggregate for filling of pressed steel frame and hold fast blocks etc complete all as specified and directed by engineer - in - charge. 24 s & f factory made plain framed, panelled shutter iind class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm b.w.p. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per is : 1003 (part i), kiln seasoned and chemically pressure treated complete all as specified and directed by engineer - in - charge. 25 s & f factory made 35mm thick iind class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in ssr part – i, section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by engineer - in - charge. 26 s & f100 mm aluminium alloy anodised butt hinges, and fixed with steel scerws for frp doors/pvc door, type b-21complete all as specified and directed by engineer - in - charge. 27 s & f in repair 100 mm mild steel butt hinges, and fixed with steel scerws for wooden doors, complete all as specified and directed by engineer - in - charge.note :- rate deemed including necessary welding etc) 28 s & f tower bolt 200 mm of aluminum complete all as specified and directed by engineer - in - charge. 29 s & f in repair tower bolt 200 mm of aluminum complete all as specified and directed by engineer - in - charge. 30 s & f door handle d type 150 mm of aluminum complete all as specified and directed by engineer - in - charge. 31 s & f in repair door handle d type 150 mm of aluminum complete all as specified and directed by engineer - in - charge. 32 s & f aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed. 33 s & f in replacement aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed. 34 s&f floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. 35 s&f in repairs floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. 36 s & f mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified. 37 s & f in repairs mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified. 38 s& fstainless steel curtain rod 25 mm dia , including fancy type brackets and pair of decorated end knobs (finials), stop roller etc.as per site requirement, fixed to wall with fixing accessories,including taking down old existing curtain rods any description complete all as specified and directed by engr-in-charge. 39 s&f factory made box type steel window with side hung shuters both glazed and gauged, shutter frame 60x25mm erw hollow p section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx70mmx1.60mm thick including fixing glazed portion, iron grills 8mm suare ms barhinges with steel handle and fitting, lugs etc., including one shop coat of primer complete all as specified.(drg no btd889 sheet 1/4 ).note :- (i) wire mesh and glass shall be measured and paid separately under relevent items of sch/boq.(ii)measurement for payment shall be the opening area of the window between inner edges of wall. 40 s&f factory made box type steel window with side hung glazedshutter, frame 60x25mm erw hollow p section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx70mmx1.60mm thick including fixing glazed portion, iron grills 8mm suare ms barhinges with steel handle and fitting, lugs etc., including one shop coat of primer complete all as specified.note :- (i)wire mesh and glass shall be measured and paid separately under relevent items of sch/boq.(ii)measurement for payment shall be the opening area of the window between inner edges of wall. 41 s&f stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as specified. 42 s & f in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as specified. 43 s & f 4 mm thick sheet glass ordinary quality and glazing within square not exceeding 0.50 sqm including aluminium cleat/rubber beading in each pane complete all as specified and directed by engineer - in - charge. 44 supply & fixing aluminium anodisedframes/chowkhats,shutter and like made out of aluminium sectionpowder coated(minimum thickness of powder coating not less than 50 micron) for window, ventilators and aluminium partition with one or more rebates or without rebate including joining cleat for fixing etc., the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawal plug and screw or with fixing clip or with expansion hold plate fasteners. aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required complete all as specified and as directed by engineer-in-charge.. 45 s & f figured glass 4 mm thick pin head type and glazing withnot exceeding 0.50 sqmincluding aluminium cleat/rubber beading in each pan complete all as specified and directed by engineer - in - charge. 46 material and labour for machine cut 16 to 18 mm thick, kota stone slab (size of slab not less than 500x550mm for flooring and in single piece for treads of staircase), laid over and including 20 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) andpolishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by engineer-in-charge. 47 material and labour for machine cut 16-18mm thick, kota stone slab as in skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangularcomplete all as specified and as directed by engineer-in-charge. 48 taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. 49 m & lfor rendering 15mm thik on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement. 50 m & lfor rendering 15mm thick on fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement. 51 m&l rendering10 mm thick in cement mortar 1:3 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement. 52 m&l integal water proofing compound 53 preparation of new plastered surfaces/existing platered surfaces and applyingwall care putty in internal/external walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony/ceilings etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior/exterior painting complete all as specified and directed.note : (i) the prepared surface after wall putty, the contractor will inform to the ge as well as to the engineer-in-charge for site inspection before applying further external finishes. please note that the further external finishes work will start only after approval of the prepared surface from the ge as well as to the engineer-in-charge through site order. 54 preparation of surfaces and applying 02 coats of interior emulsion paint (light shade) @ 12 sq.m/litre/2 coats by using spray gun to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. 55 preparation of surfaces and applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats by by using spray gun to ceiling surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. 56 preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade)@ 5 sq.m/litre/2 coats by using spray gun to external walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. 57 preparation of new/existing plastered surfaces as in ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer-in-charge. 58 preparation of new/existing plastered surfaces as in walls and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer-in-charge. 59 m & l providing two coats of synthetic enamel paint over new steel surfaces and a coat of red oxide primer onincluding preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by engineer -in -charge. 60 m & l providing two coats of synthetic enamel paint over new wooden surface including preparation of surface withprimer all as specified. 61 m&l for preperationof old steel surface and applying two coat of synthetic enamel paint complete all as specified and directed by engineer -in -charge. 62 m&l for preperationof old wooden surface and applying two coat of synthetic enamel paintcomplete all as specified and directed by engineer -in -charge. 63 m&l for shotcreting 25mm thick in rcc columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 kg/cum on m-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc as directed by engineer-in-charge including chipping of unsound /weak concrete material 25 mmaverage thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with dr fixit epoxy zinc primer or equivalent @ 6sqm/ltr at dft of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of engineer-in-charge. 64 m&l hard drawn steel wire fabric not exc 4kg/sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntall as specified & directed by engineer-in-charge. 65 m & l 5mm thick rendering in cement mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cementcomplete all as specified and directed by engineer - in - charge . 66 dismantling structural steel work including doors,gates but excluding framed truss etc. 67 s & f framed work such as grills,cooler stand ,ladder grating and sun shed etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming tofe 410-0 or fe 310-0 all as specified . 68 dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices. 69 s&f glazed ceramic colouredtiles joint free 350x250x7mm/450x350x7mm square or rectanguleras on walls etc set and jointed in neat cement slurry and pointed in whiteor coloured cement to match over and including 10mm thick rendering in cm 1:4 complete all as specified and directed by engr-in-charge. 70 m&l non skid ceramic coloured /printed tiles 7 to 8 mm thick( square / rectangular) area of each tile exc. 0.11 sqm but n. exc, 0.18 sqm in floor and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shadeover and incl 15 mm thick screed bed in cm 1:6 complete all as specified and directed by engr-in-charge. 71 m&l cement concrete type b-0, 1:2:4 using 12.5 mm graded stone aggregate as in floors 25 mm thick for tilesall as specified.& directed by engr -in-charge.. 72 m&l 16-18 mm thick granite (of any type ) work (table rubbed and polished ) in cooking platform and likein cm (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding/moulding of edges. 73 demolitionof cement concrete ( un re-inforced) of any description in ground floor and pavings exc15 cm thickness (below or above gl). 74 material and labour for water proofing treatment to rcc sunken slab and adjoining vertical slab as described following any one method complete as per directions of ge. 75 method 1(a) supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, smart care damp proof 2k, having 100% elongation as per astm d412, resisting 5 bars hydrostatic pressure as per din 1048, reduction to rapid chloride shall be 70 as per din 1048, crack bridging upto 1.2mm as per astm 4548.5 clean all working surface & made free from dirt, grease laitance etc. after inspection for all working area rough surface, cracks & from dirt, grease laitance etc. after inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 cement : 1polymer : 4 sand). making gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 cement : 1 polymer : 4 sand). the coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. the mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(b) bore packing: all the borehole gaps between concrete surface and pvc pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – smart care gp grout having dual shrinkage compensation property. before the bore packing, surface of the pvc pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent. (c) apply12-15mm plaster on slab and vertical surface admixed with smart care vitalia neo @200ml per bag of cement before treatment. 76 method 2(a) supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm dft, having hydrostatic (positive) water pressure resistance (din 1048) is 7. abrasion resistance, cm/km is 0.09 of dr fixit pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. the polyester reinforced coated netof 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer dr fixit pidifin 2k. after removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola onsurrounding wall’s junction and seal the vertical walls. in case of core cutting on the surface, the joint is seal with non-shrink grout.(b) the coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(c) apply12-15mm water proof plaster on slab and vertical surface admixed with dr fixit pidiproof 77 m & l pcc (1:5:10)using 40mm graded burnt bricksaggregate as in foundation filling & mass concrete or as in sunkenfloor complete all as specified & directed by engineer-in-charge 78 dismantling water tanks and removing to store ofexc 500 and nexc 1000 ltr capacity 79 s & f rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in ssr part i of capacity 1000 litres all as specified and directed by engineer - in - charge . 80 s&f in repair 20mm ball brass valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed. 81 s & f in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified . 82 s & f in 25 mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified . 83 s & f in repairs pvc 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of pvc 32mm bore and connection to wc pan complete all as specified. 84 s&f in repair viterous china squating pan orrisa pattern size 580/440mm wash down water closet pan ,white (excluding fixing bolts, flushing cistern and flush pipe) with plastic seat cover. 85 s&f in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe ,anti-syphonage pipe and white closed patern with flat bottom & mild steel cromium plated or aluminium hinging device plasticseat cover complete . 86 s&f repairs vitreous china half stall urinals flat back white minimum with grating and union for discharge pipe ,providing & fixing plugs, bedding urinal against wall in cm 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified. 87 s & f in repairs vitrous china oval wash hand basin white of size 550x400 mm including brackets 300mm long pvc connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etccoloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified. 88 s&f in repair 600mm x 450mm beveled edge mirror of selected quality glass on 6mm thick commercial plywood and fixed wooden plugs with chromium plated brass screw and cup washes fixed in repair. 89 s & f repairs 15 mm bore concealed stop cock cast copper alloy screwed down high pressurewith crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated with long shank and cup (concealled type) 90 s & f in repairs 15mm bore angle cock one waychromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified . 91 s & f in repairs 15 mm bore bib tap fancy type chromium plated with crutch or butterfly handle screwed down ,screwed for iron pipe all as specified. 92 s&f in repairs pillar taps 15mm borefancy type chromium plated cast copper alloywith capstan heads scre-wed down high pressure with or without lettered hot orcold with long screwed shanks and fly nuts screwed for iron pipe . isi marked 93 s&f in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by engr-in-charge. 94 s&fin repair brass chromium plated shower rose 125mm size with swivel joints,any size, incl shower arm fixing to pipe or union complete all as specified and directed by engr-in-charge. 95 s&f in repair pvc connection both side brass unions internal for size 15mm dia and 450mm long all as specified and directed by engineer-in-charge. 96 s&f ewc jet spray complete all as specified and directed. 97 s & f in repairsoap dish approximately size 160 x160x 90 mm and fixed withas chromium plated brass screws complete all as specified and directed by engineer -in -charge. 98 s&f peg set of stainless steel solid body of 125mm to 175 mm having 6 nos hooks fixed with brass chromium plated screws complete in all as specified 99 taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by engr-in-charge. 100 fixing only mild steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified & directed by engineer-in-charge. 101 supply & fixing mild steel tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed complete to wallall as specified & directed by engineer-in-charge. 102 taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store omplete all as specified and directed by engineer -in -charge. 103 supply & fixing of 16mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing omplete all as specified and directed by engineer -in -charge. 104 supply & fixing of 20mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing omplete all as specified and directed by engineer -in -charge. note :-(i) pipes inside the buildings shall be fixed concealed and outside the buildings shall be fixed on the surface along wall with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, as directed by engineer-in-charge.(ii)bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on btd drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. 105 supply & fixing of 25mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing complete all as specified and as directed.note :- (i) pipes inside the buildings shall be fixed concealed and outside thebuildings shall be fixed on the surface along wall with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, as directed by engineer-in-charge.(ii) bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on btd drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. 106 taking up or down steel tubing of 25 to 32 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by engr-in-charge. 107 s & f 40mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by engineer - in - charge. 108 dismantling of cast iron pipes jointed in cement mortar and taking out from trenches walls etc upto 100 mm bore all as specified and directed by engr-in-charge . 109 supply & fixing 110mm bore upvc pipes grade b single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant c complete all as specified and directed by engr-in-charge. 110 supply & fixing 75mm bore upvc pipes grade b single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant complete all as specified and directed by engr-in-charge. 111 supply & fixing upvc junction (double t/socket) grade b equal or unequal suitable for 110mm bore pipe complete all as specified and complete all as specified and directed by engr-in-charge. 112 all as per item no 109 above 113 supply & fixing upvc bends (any radius) grade b suitable for 110mm bore pipe complete all as specified and directed by engr-in-charge. 114 all as per item no 111 above 115 supply & fixing upvc vent cowl grade b suitable for 110mm bore pipe complete all as specified and directed by engr-in-charge. 116 supply & fixing pvc vent cowl grade b suitable for 75 mm bore pipe complete all as specified and directed by engr-in-charge. 117 supply & fixing upvc grade b multi floor trap 110 mm bore and 600mm long with grating including jointing with with pipe joint lubricant complete all as specified and directed by engr-in-charge. 118 supply & fixing upvc grade b multi floor trap 75 mm bore and 600mm long with grating including jointing with with pipe joint lubricant complete all as specified and directed by engr-in-charge. 119 demolition of brick work built in cement mortar including all quoins, arches, pillars etc . 120 m&l for brick work with subclass‘b’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by engineer-in-charge. 121 labour only forbrick work built in cm (1:6) with subclass b bricks, straight or curved on plan exceeding 6m mean radiuswith reusing the old bricks obtained fromitem no 118 . 122 m&l for taking down carefully point wiring complete including fixture and fittings from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc and making good to disturbed area all as specified 123 m&l for point wiring complete with isi marked 1.5 sqmm single core pvc insulated unsheathed cable 1100v grade frls with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories includingpvc rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, ms hooks, ms junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switchs, sockets, fan regulator etc covered with 3 mm thick plastic laminated hylem top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer includingfixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for the following all as specified 124 (a)one light point/fan point/exhaust controlled byone way switch 125 (b)one light point controlled by one two way switch 126 (c)one 5 pin socket out let 5 amps on the same board with other switches 127 (d)one 5 pin, 5a switch socket outlet point on independent board with other switches. 128 all as per item no. 02 here-in-before but with 2.5 sqmm cable for 1no 16 amps socket outlet point on independent board including 2.5 sqmm pvc insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified 129 s&f piano type switch single pole 1 way 5/6 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 130 s&f socket two in one 6/5 pin 5 amps230 volt ac supply complete all as specified and directed by engr-in-charge. 131 s&f piano type switch single pole 1 way 15/16 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 132 s&f piano flush type switch single pole 2 way 15 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 133 s&f socket two in one 6/5 pin 15/16 amps230 volt ac supply complete all as specified and directed by engr-in-charge. 134 s&f ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / pvc / polycarbonate isolated body complete all as specified and directed by engr-in-charge. 135 s & f stepped type electronic fan regulator flush type on the existingphenolic laminated sheet etc. as reqd complete all as pecified and directed. 136 s&f lamp holder, pvc/polycarbonate type with back plate suitable for batten fittings with led bulb 09 watt complete all as specified 137 supply and fixing led lights fitting 20 w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 138 supply and fixing led light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete. 139 supply and fixing led street light fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete. 140 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amps capacity complete all as specified and directed by engr-in-charge. 141 s&f sheet metal enclosure for vtpn dbs 415 volts 08 way with 200 amps rated bus bar neautral link, earth bar double door with mccb as incomer complete all as specified 142 s&f sheet metal enclosure for vtpn dbs 415 volts 04 way with 200 amps rated bus bar neautral link, earth bar double door with mcb tpn as incomer complete all as specified and directed by engr-in-charge. 143 s&f sheet metal enclosure for dbs spn 230 volts 12 way with 200 amps rated bus bar neautral link, earth bar double door complete all as specified and directed by engr-in-charge. 144 supply and fixing 415v 16 ka 415 volts mccb of cap 100 amps following poles and current carrying capacity in the db complete with connection testing and commissioning. 145 supply and fixing 415v 10ka b curve miniature circuit breaker (mcb) tpn/4p of capacity 40 to 100 amps poles and current carrying capacity in the db complete with connection testing and commissioning. 146 supply and fixing 240v, 10 ka b curve miniature circuit breaker (mcb) of single poles and current carrying capacity 6 to 32 amp, in the mcb db complete with connection testing and commissioning complete all as specified and directed by engr-in-charge. 147 supply and fixing amp rating 240v, 10ka c curve miniature circuit breaker (mcb) of spn 40 to 63 amp and current carrying capacity in the mcb db complete with connection testing and commissioning complete all as specified 148 m&l forsubmain wiring comprising single core , 2 runs of 2.5 sqmm nominal cross sectional areamulti stranded copper conductor cable, pvc insulated unsheathed 1100 volts gradedrawing in and including appropriate dia. in surface/recessed pvc conduit and its fittings completeincluding provision of 1x2.5 sqmm nominal cross sectional areamulti stranded copper conductor cable, pvc insulated unsheathed 1100 volts grade as earthwire and using color code as per is and specified and making good all disturbed work to match the existing complete incl taking down old unsv sub main complete all as specified and directed by engr-in-charge. note :- (i)extra length of cables/ wire required for connection to mcbs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly.(ii) two run of wire, one run of earth wire and conduct shall be measured as one unit. 149 all as per item no 142 abovebut for single core , 2 runs of 4.0 sqmm nominal cross sectional area including provision of 1x4.0 sqmm nominal cross sectional area complete all as specified and directed by engr-in-charge. 150 all as per item no 142 above but for single core , 2 runs of 6.0 sqmm nominal cross sectional area including provision of 1x 6.0 sqmm nominal cross sectional area complete all as specified and directed by engr-in-charge. 151 m&l for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal gl connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washersand earth strip protected by 15 mm dia gi pipe medium grade and connected to main distribution board panel/earthing test point all as shown on electrical plate no.3 of ssr part i and all as specified including testing on completionincluding taking down old unserviceable earthing any type complete all as specified and directed by engr-in-charge. note :-gi wire 4mm dia including test point terminal box include in the quoted rate.
  • View Tender
  • Document
  • Bid Support
58 Security Services
image image
Central Government/Public Sector
TRN :49054237 |  29 May, 2025
Tender Value : 10.00 Lacs
 Srinagar - Jammu And Kashmir
Tender for repair and maint to flooring, plastering, joinery, roofing, bathroom, kitchen, sunken floor, leakage, seepage and other connected b/r works at 663 army avn, stn hq, 1690 fpo and mes at sharifabad mil stn under age (i) cif (k)
  • View Tender
  • Document
  • Bid Support
59 Rural Development
image image
Local Bodies
TRN :49054292 |  26 May, 2025
Tender Value : 2.96 Crore
 Firozabad - Uttar Pradesh
Tender for tender for construction work of theme park with in municipal corporation firozabad. - art work 2 shree banke bihari temple - the structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 20 feet. minimum width – 15 feet. minimum length – 28 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 3 cow - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 8 feet. minimum length – 12 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 4 krishna jhoola - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 5 feet. minimum length – 10 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 5 sheshnag - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 12 feet. minimum width – 15 feet. minimum length – 30 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 6 morpankh- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 15 feet. minimum width – 2 feet. minimum length – 6 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 7 pot- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 10 feet. minimum width – 10 feet. minimum length – 12 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 8 fluite- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 2 feet. minimum length – 20 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 9 goverdhan parvat.- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 20 feet. minimum width – 6 feet. minimum length – 20 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 10 external lighting work 11 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63mm dia (od- 63 mm andid 51 mm) 12 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90mm dia (od- 90 mm andid 76 mm) 13 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia ((od- 120 mm andid 103 mm) 14 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 15 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a )25 mm 16 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required . 17 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required . 18 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required . a)single pole 19 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required .b)single pole and neutral 20 supplying and fixing following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (rccb) having a sensitivity current 30 ma in the existing mcb db complete with connections,testing and commissioning etc.as required.40a 21 supplying and fixing following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (rccb) having a sensitivity current 30 ma in the existing mcb db complete with connections,testing and commissioning etc.as required.63 a 22 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required . b) 125 a,36ka,fpmccb 23 supplying, instalaltion, testing & commissioning of1.1 grade, 3x1.5sqmm frls pvc insulated flexible copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required. 24 supplying, instalaltion, testing & commissioning1.1 grade, 3x2.5sqmm frls pvc insulated flexible copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required. 25 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx4 sqmm 26 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx6 sqmm 27 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx10 sqmm 28 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx16 sqmm 29 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx25 sqmm 30 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19883.5c x 70 sqmm 31 supply, installation, testing and commissioning of 50 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 32 supply, installation, testing and commissioning of 30 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 33 supply, installation, testing and commissioning of 90 -100 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 34 supply,installation,testing and commissioning of 25-30 watt warm white ledlinear wall washer luminaire cct 3000k ± 250k for illuminate 3d wall painting with aluminium extruded housing. length of the luminaire shall be 1000mm in size.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270vac ,50hz , powerfactor>0.9. fixture shall be suitable to operate at ambient temperature range of-5°cto+50°c and shall be ip65 and ik06 rated. lifetime should be at least l70:50000 burning hours at 50°c. luminaire shall be conforming to bis and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required engineer-in-charge. the branding name shall be embossed on the housing of the fixture. the minimum warranty shall be for 2 years. 35 supply,installation,testing and commissioning of 40-45 watt warm white ledlinear wall washer luminaire cct 3000k ± 250k for illuminate 3d wall painting with aluminium extruded housing. length of the luminaire shall be 1000mm in size.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270vac ,50hz , powerfactor>0.9. fixture shall be suitable to operate at ambient temperature range of-5°cto+50°c and shall be ip65 and ik06 rated. lifetime should be at least l70:50000 burning hours at 50°c. luminaire shall be conforming to bis and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required engineer-in-charge. the branding name shall be embossed on the housing of the fixture. the minimum warranty shall be for 2 years. 36 sitcjunction boxes outdoor type supply made of thermoplastic polycaronateboxes mini. size 93 x 93 x 62 mm in black colour. the junction box should be ip 67/69 ( iec 60529 ) thermoplastic pc weatherproof with multi level knockouts on four side for cable entry in different sizes . lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. the box should be uv resistant in accordance with iec 61 439-1, clause no 8.4.4. the joint box should be weatherproof : rainwater proof, temperature resistant, connecting box as per iec 60670-22 and iec 60695 – 2 – 11 : flame – retardant & self-extinguishing. glow wire tested at minimum 750 deg c. the box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable terminals . the junction box with nut bolts complete all as per manufacturer’s instructions.make : cat part :- kf 0202 b of hensel/siemens/ge power/schneider/ l&t/abb. manufacturer should submit test certificate as per above standard. 37 sitcjunction boxes outdoor type supply made of thermoplastic polycaronateboxes mini. size 205 x 255 x 112 mm in black colour. the junction box should be ip 67/69 ( iec 60529 ) thermoplastic pc weatherproof with multi level knockouts on four side for cable entry in different sizes . lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. the box should be uv resistant in accordance with iec 61 439-1, clause no 8.4.4. the joint box should be weatherproof : rainwater proof, temperature resistant, connecting box as per iec 60670-22 and iec 60695 – 2 – 11 : flame – retardant & self-extinguishing. glow wire tested at minimum 750 deg c. the box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable terminals . the junction box with nut bolts complete all as per manufacturer’s instructions.make : cat part :- kf 02525 b of hensel/siemens/ge power/schneider/ l&t/abb. manufacturer should submit test certificate as per above standard. 38 providing and fixing of flexible led strip fixtures suiatable for rated voltage 220 volts, 50 hz supply in white /green/red/warm white color including all accessories like connectors, endcap,holding cap and connector pins but excluding integrated led adoptor etc as required. 39 providing and fixing of integrted led adaptor forflexibleled strip fixtures suiatable for rated voltage 220 volts, 50 hz supply etc as required. 40 horticulture 41 horticulture ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size hdpe bag 42 supply of ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in polybag of size 25 cm as per diraction of officer-in-charge 43 supply of rhapis palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed,full of fresh andhealthy leaves in 25 cm size of earthen pot / plastic pot. as per direction of the officer-in-charge 44 supply of areca palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in hdpe bag as per direction of the officer-in-charge 45 supply of wadelia trilobata,full of leaves in 15 cm size in plastic bag as per direction of the officer-in-charge 46 supply of syngonium (butterfly) variegated with 2-3 suckers healthy foliage in earthen pot/ plastic pot of size 25 cmas per direction of the officer-in-charge 47 supply of iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of earthen pot / plastic pot. as per direction of officer-in-charge 48 providing and fixing furcaria variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm cement pot as per direction of the officer-in-charge. 49 providing and displaying topiary of ficus panda well developed with fresh & healthy foliage with 3 to 4 ball and 60 to 75 cm spread each ball, 135 to150 cm ht., in 35 cm hdpe bags /cement pot as per direction of theofficer-in-charge. 50 providing and displaying cyprus golden conical shape 150 to 165 cm ht., with fresh and healthy golden colour foliage in 35cm cement pot as per direction of the officer-in-charge. 51 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. 52 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 53 providing and displaying cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge. 54 providing and displaying bismarckia palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm cement pot as per direction of the officer-in-charge. 55 providing and fixing fishtail palm ht. 240cm bottom girth 40-50 cm well developed in big hdpe bag 56 civil work 57 earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by engineer-in- charge:all kind of soil 58 construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mix plant at omc, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of engineer-in-charge.with material conforming to grade-i (size range 75 mm to 0.075 mm) having cbr value-30 59 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 60 providing and laying 60 mm thick faciory made cement concrete interlocking paver block of m -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer-in-charge. 61 constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand)cluding 500x450 mm pre-cast r.c.c. horizontal grating with frame complete as per standard design : 19.27.1 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 62 providing and fixing g.i chain link fabric fencing of required width in mesh size 50x50mm including strengthining with 2mmdia wire or nuts,bolts and washer as required 63 steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works 64 cc for flooring provision and laying in position cement concrete of specified grade excluding and cost of centering and shuttering. allwork upto plinth level in cc 1:3:6 (1 cement: 3coarse sand: 6 graded stone aggregate 20 mm nominal size) 65 brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 66 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) 67 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
  • View Tender
  • Document
  • Bid Support
60 Security Services
image image
Central Government/Public Sector
TRN :49054308 |  29 May, 2025
Tender Value : 10.00 Lacs
 Srinagar - Jammu And Kashmir
Tender for repair and maint to flooring, joineries, plastering, sanitary works etc in hq cif(k) under age (i) cif (k)
  • View Tender
  • Document
  • Bid Support
  • 1
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • ...
  • 21
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : interlock paver
  • Concrete Flooring Repair Tenders ,
  • Antistatic Tenders ,
  • Wooden Laminated Flooring Tenders ,
  • Efficiency Flooring Tenders ,
  • Floor Covering Work Tenders ,
  • Flexible Vinyl Flooring Tenders ,
  • Stone Flooring Tenders ,
  • Cement Concrete Tiles Repair Tenders ,
  • Marble Flooring Tenders ,
  • Block Paving Tenders

Get interlock paver Tender Alert...

927571

Related Searched Keywords : interlock paver

  • Civil Engineering Tenders From Maharashtra
  • Dismantlement Tenders From Delhi
  • Dismantling Tenders From West-Bengal
  • Flooring Tenders From -Tamil-Nadu
  • Tubewell Tenders From Andhra-Pradesh
  • Floor Tiling Tenders From Gujarat
  • Water Proof Tenders From Karnataka
  • Drilling Tenders From Uttar-Pradesh
  • Submersible Borewell Tenders From Rajasthan
  • Railway Bridge Tenders From Madhya-Pradesh

Read More


Tender Document

209001

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Underground Sewer Tenders
  • Construction Work Tenders
  • Wall Work Tenders
  • False Ceiling Tenders
  • Tubewell Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App