Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Rig Machine
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of rig-machine Tenders

List of latest rig-machine Tenders in Indian Tenders. Click on any rig-machine Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for rig-machine Tenders.

Advance Search
  • All-Tenders (43)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Construction
image image
State Government
TRN :49051926 |  16 May, 2025
Tender Value : 30.36 Lacs
 Panaji - Goa
Tender for construction of hall and supplying gym items for pinto youth club of baradi in velim constituency under mla-lad scheme.--demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. 2 demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. 3 laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. 4 extra for laterite masonry in all sizes in superstructure from floor i level upto floor v level. 5 12mm cement plaster 1:4 (1 cement : 4 fine sand) 6 providing and fixing 1st quality ceramic glazed wall tiles (johnson somany kajaria ) conforming to is:15622 (thickness to be specified by the manufacture of approved make in all colours shades except burgundy bottle green black of any size as approved by engineer-in-charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.;wall ceramic glazed tiles : 300 x 600 7 providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of johnson somany kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to is: 15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc. complete;dark shades 8 proving and fixing white vitreous china wall hung type (european type) water closet with seat and lid with c.i. brass hinges and rubber fittings with flush valve nelson/ similar fully chromium plated with stop cock wall flanges flush pipe or elbow and vaccum breaker coupling etc. including chair bracket/rag bolts cutting & making good the walls and floors where required and concealed seat support - w.c. pan with white plastic seat and lid 9 providing and fixing brass stop cock (heavy) of approved quality :;15 mm nominal bore 10 providing and fixing brass full way valve (heavy) duty with wheel of approved quality :;20 mm nominal bore 11 providing and fixing p.v.c. connection pipe with brass unions 15 mm nominal bore:;45 cm (18”) length . 12 providing and fixing rigid pvc s.w.r. (soil waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:; 110 mm dia 13 providing and fixing rigid pvc bend (approved make) for s.w.r. pipes including lubricating etc complete bend with door :; 100 mm dia 14 providing and fixing nahani trap of rigid pvc (approved make ) for s.w.r. pipes including lubricating etc complete without door :;110 mm dia 15 providing and fixing nickel chrome plated copper alloy fancy bib cock short body jaquar make or equivalent.confirming to is 8931; 1993;15mm nominal bore 16 providing and fixing chlorinated ployvinyl chloride (cpvc) pipes confirming to is:15778 having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. this includes jointing of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of the engineer-in-charge. concealed work (medium duty sdr 13.5 pipe) including cutting chases and making good the walls etc.;20 mm dia nominal outer dia pipes. 17 providing and fixing hand shower (health faucet) with 8mm dia abs/brass body with double lock 1.00 m long flexible tube (brass plated stainles steel flexible hose) and wall hook of approved quality confirming to is standards. 18 frp (fiber reinforced polymer) frames with wood finish manufacture supply and installation (with anchor fastener) of epee or equivalent goan make frp (fiber reinforced polymer) frame of cross section as per options below with right angle joint and frp (fiber reinforced polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). the core of frame would be filled with seasoned wood as infill material. the slot of frame for door resting will be of suitable width so as to take specified thickness door.the frame will be water proof as well as mild acid/ alkali resistant manufactured in an iso 9001- 2015 certified company.;specified cross section;4” x 2” 19 wood finish wood core frp (fiber reinforced polymer) door shutter. manufacture supply and installation (including accessories as mentioned below) of epee or equivalent goan make frp (fiber reinforced polymer) door shutter of specified thickness as per options below by using tray system with seasoned hard wood moisture less than 17% wooden styles for top rail and lock rails. frp (fiber reinforced polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) and printed matt having wooden textures used along with uv resistant resin to give the clear texture on the door. the core of shutter will be filled with mr 2nd grade block board. the shutter to be water proof as well as mild acid / alkali resistant manufactured using rv tifac (r v engineering college bangalore & technology information forecasting & assessment council) technology in line with is 13034 1990 test standard in an iso 9001 – 2015certified factory. accessories: i) s. s. hinges 4” - 3 nos ii) s. s. latch - 1 no iii) tower bolt 5” - 2 nos iv) handle 5” - 2 nos;shutter thickness;32mm 20 providing and applying white cement based putty of average thickness 1.00 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. 21 applying one coat of cement primer of approved brand and manufacture on wall surface. 22 wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. 23 painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. 24 applying priming coat with ready mixed primer of approved brand and manufacture on steel work. 25 providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts nuts and wooden plugs and embeded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size.;40 x 3 mm flat iron hold fast 15 cm long 26 providing and fixing m.s. grill of required pattern in wooden frames of windows etc. with m.s. flats square or round bars with round headed bolts and nuts or by by screws.; plain grill 27 centering & shuttering including strutting propping & removal of forms for :;columns piers pillars aburments posts and struts (square rectangle polygon in plan) 28 centering & shuttering including strutting propping & removal of forms for :;sides and soffits of beams beam haunchings cantilever girders bressumers and lintels plinth beams not exceeding 1m in depth 29 centering & shuttering including strutting propping & removal of forms for :;suspended floors roofs landings shelves & their supports 30 providing and fixing 18 mm thick gang saw cut mirror polished premoulded and prepolished machine cut for kitchen platforms vanity counters window sills facias and similar locations of required size approved shade colour and texture laid over 20 mm thick base cement mortar 1: 4 (1 cement : 4 coarse sand) joints treated with white cement mixed with matching pigment epoxy touch ups including rubbing curing moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite of any colour and shade area of slab over0.50 sqm;jet black 31 providing and laying in position machine batched concrete (bmc) machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering shuttering finishing and reinforcement including admixtures in recommended proportions as per is 9103 to accelerate retard setting of concrete improve workability without impairing the strength and durability as per the direction of the engineer-in-charge. m25 grade of reinforced cement conrete by using 410kg of cement per cu.m. of concrete. all works upto floor v level. 32 providing tmt steel reinforcement bars of (sail tata. vizag jsw steel ltd.) ) (confirming to is 1786 of 1986) for rcc work (conforming to i.s. 1786 of 1986) including bending binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. 33 providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the engineer-in-charge: windows with three sliding shutters using 18 mm series shutters section.;plain glass 34 extra for powder coating with pure polyester powder of shade of required colour on the aluminium section 35 providing and fixing vitreous china wash basin with rs or c.i. brackets painted white 15 mm c.p. brass pillar taps c.p. brass chain with rubber plug 32 mm c.p. brass waste of pattern 32 mm diameter m.i. or c.p. brass trap and union complete including cutting and making good the walls where required.; flat back wash basin size 550 x 400mm with a single 15 mm c.p. brass pillar taps. 36 providing and laying in position cement concrete 1: 2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering shuttering and finishing :;all works upto plinth level 37 providing and fixing astm upvc pipe conforming to astm 2467 with iso 14001 including all upvc plain & brass threaded fittings including jointing of pipes & fittings with one step upvc solvent cement trenching refilling & testing of joints complete as per direction of engineer. external work.;sch-80(blue)/(w hite);40mm outer dia. 38 providing and fixing g.i. chain with g.i. pull. 39 providing woodwork in frames of doors windows clerestory windows trusses & other frames wrought framed and fixed in positon.;second class indian teak wood 40 providing and fixing 38 mm thick panelled glazed or panelled and glazed shutters for doors windows and clerestory window including black enamelled iron butt hinges with necessary screws:;second class indian teak wood 41 applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete. 42 painting two or more coats (excluding priming coat) with superior quality ready mixed paint for wood work of approved brand & manufacture in all shades on new work to give an even shade. 43 providing & fixing chromium plated brass tower bolts (barrel type) with necessary screws complete.;250 x 10 mm 44 providing and fixing chromium plated brass sliding door bolt with bolts nuts and screws etc. complete.;300 x 16 mm 45 provided and fixing 150 mm chromium plated brass floor door stopper with rubber cushion screws etc. to suit shutters thickness complete. 46 provided and fixing chromium plated brass 100mm. mortice latch and a pair of levers and handles with necessary screws etc. complete (indian make of approved quality). 47 providing and and laying vitrified floor tiles in different sizes of johnson somany kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigment etc. complete;600 x 600 mm light shades 48 false ceiling:-;providing & fixing false ceiling yashashri make or equivalent made out of 2” x 1” m.s sq tube frame support structure & 20mm x 155mm x 1.2mm multi- cavity upvc section 30mm x 40mm x 2mm upvc multi-cavity section with hidden screwing system.the average weight of false ceiling is 8.50 kg per sq mtr. these upvc sections are tested by using bs 2782 & din 53459 test methods. 49 providing & fixing of aluminium lay-in perforated tile ceiling on 24 /14 mm ‘t’ framework of module 600mm x 600mm. tiles of size 575mm x 575mm / 584mm x584mm made out of 0.6mm thick aluminium. perforation of the tiles shall be 2.5mm dia 5.5mm c/c. the tile shall be manufactured on advanced equipment which includes several levelling. the tile end shall be raised upward by 38mm and bend outward to lay the tile in framework. the tile shall be polyester based powder coated in white colour. grid system for fixing ceiling tiles shall comprise of tees. the 24 /14 mm main tee runners shall be suspended at an interval of 1200mm centre to centre. the 24 /14 mm cross tee runner shall be suspended at 600mm centre to centre and further supported with 24 /14 mm cross tee at 600mm centre to centre with interlocking arrangements to form grid of 600mm x 600mm. the main tee shall be supported by means of 4mm g.i. rod from slab/roof. the suspension shall be provided at 1200 to 1500mm centre to centre.tee framework would be made of gi and powder coated. acoustic felt: non- woven felt made of glass-r einforced fibre glued over the perforation for sound absorption. 50 providing water proofing treatment over the new r.c.c. roofs terrace toilet by spreading cement slurry over the r.c.c. slab and laying of 10cms. average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of hindustan water proofing co. or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand) finished smooth with wooden trowel with false marking of 30 cms square. the vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. the injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb cracks etc. in the r.c.c. slabs). note: cement consumption 25 kg/sq.m. 51 providing & fixing colour coated alluminium (puf) sandwich panel roofing systems of approved make adhering to aluminium 3105 grade for top & bottom sheet of thickness0.40 & 0.35 respectively including puf insulation betewwn the top & bottom sheet of denslity 40 (+/-2) kg/m3 inclusive of s.s. 304 grade self tapping fastneres complete as directed by enigneer incharge (frame work for roof roof accesorries to be paid seperately) for tile design puf roof panel gutter width should be atleast 25% more than the crest width. minimum height at heighest point of crest should be minimum 65mm. minimum thickness at anygiven point should not be below 30mm.;puf insulated tile roof 30mm thick of trapezoidal design 52 steel work in built up tubular (round square or rectangular hollow tubes etc.) (square hollow section (shs) is4923 /rectangular hollow section (rhs) is4923/circular hollow section (chs) is1161 closed structural steel of (sail tata. vizag jsw apollo steel ltd.) make (min yeild stress 310 mpa)) trusses etc. including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc. complete. 53 providing and fixing in position s.s. hand rail in main stair case and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials etc. complete. 54 melamine polishing on wood work (one or more coat);glossy 55 providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the engineer-in-charge: adjustable louvered window s.;figured glass 56 extra for powder coating with pure polyester powder of shade of required colour on the aluminium section 57 6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand) 58 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. 59 painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as dulex/ asian paints/ sherwin willians) including applying one coat of cement primer and one coat of surface treatment etc. complete. 60 painting one or more coats of acryllic exterior paint of approved brand and manuf acture(such as dulex/ asian paints/ sherwin willians) on old work including cleaning the surface with water etc. complete. 61 providing & fixing alluminium ridge of approved make adhering to alluminium 3105 grade of 0.71mm thickness & 60 cm wide inclusive of ss304 grade self tapping fastners to match the alluminium roofing system & as directed by engineer in charge complete 62 providing & fixing alluminium 30mm trapezhoidal end cap for puf roofing of approved make of alluminium aa 3105 grade matching with 30mm puf panel profile including the required fastners etc. complete for alluminium puf roofing system & as directed by engineer in charge. 63 pvc wall paneling : providing and fixing pvc sheet wall paneling of thickness 5mm (±0.25) consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm (±0.25) thick prelam pvc sheet.the panel & strips shall be of 600 kg/cbm density manufactured by an iso-9000 certified company. the strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two pvc strips. the pvc strips shall be fixed to the wall using 65mm long m.s. screws through the groove in the strip by using pvc fasteners. the distance between two screws shall not be more than 200mm. a groove of 2mm may be left at the joint of two panels for aesthetic looks. the exact size of the panel and correspondingly of the grid may vary depending on the size of the wall.optionally a strips of 5mm (±0.25) thick pvc sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined using solvent cement. 64 providing and installing rubber dumbells of hexagonal shape and approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 65 providing and installing barbell rod 5ft of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 66 providing and installing skipping rope of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 67 providing and installing yoga mat 6mm thick of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 68 providing and installing punching bag of 900mm diameter of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 69 providing and installing bench press multidegree of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 70 providing and installing rowing machine of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 71 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. a)2.50 kg 72 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. b) 5.00 kg 73 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. c) 7.50 kg 74 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. d)10.00 kg 75 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e)12.50 kg 76 providing and installing rubber plates of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e) 15.00kg 77 providing and installing dumbell rack of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 78 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. a) 2.00 kg 79 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. b) 4.00 kg 80 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. c) 6.00 kg 81 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. d) 8.00 kg 82 providing and installing kettle bell of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. e) 10.00kg 83 providing and installing gym ball 65cms of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 84 providing and installing gym ball 75cms of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 85 providing and installing push up bar with chrome finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 86 providing and installing ab wheel roller finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 87 providing and installing foam roller finish of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge. 88 providing and installing air bike of approved make including all material, labour, transportation, etc. complete as directed by engineer in charge.
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
3 Security Services
image image
Central Government/Public Sector
TRN :49054152 |  20 May, 2025
Tender Value : 77.92 Lacs
 Abohar - Punjab
Tender for tender for special repair to building no p-137 at mil stn abohar; 1 demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise complete all as specified and directed by engr-in-charge. 2 material & labour for 75mm thick pcc 1:3:6, type c1, using 20mm graded stone aggregate as in hard standing ,plinth protection/path etc,laid in suitable panels n.exc 3.00 m length finished even and smooth without using extra cement with contraction(dummy)joints 65mm deepx10mm wide joints filledwithbituminous sealing compound of grade ‘a’/bitumen mastic filler/sealant complete all as specified and directed by engr-in-charge. 3 dismantling brick tiles in floor or in roofs laid dry and pointed in any cement mortar complete all as specified and directed. 4 demolition of mud in roofs any thickness incl plastering and leeping 5 m & l for 40mm thick cement concrete type b0 1:2:4, (using 12.5mm graded stone aggregate) as in, surface finished even and smooth without using extra cement 6 m & l 10mm thick rendering in cement mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by engr-in-charge. 7 m&l for preparation of roof top surfaces,providing and applying uv stable single component smart care damp proof ultra is a fiber reinforced elastomeric liquied appplied water proofing membrane formulated with pu hybrid polymers and reinforcing acrylics fibres and having sri of 106 on top of concrete roof surface in three coats including self primer at ratio pf dampproof and water 3:1 and coverage @ 1 ltr/10 sqm with a thickness of 650 micron. note : (i) 6 hrs interval between two coats will be maintained. (ii)the treatment shall be carried out by authorised applicator approved by ge as per the manufacturer(iii)payment will be made after providing warrnty certificate from the company. 8 m&l 40mm thick brick tiles laid/beded including screed bed 15mm thick in cement mortar (1:6) on existing lime concrete sufaces of roof,joints grouted flush in cement mortar (1:3) mixed with liquid wpc @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of mes sch part-i (2009) complete all as specified and directed by engr-in-charge. 9 m&l 40mm thick brick tiles( old serviceable tiles obtained from demolition/desmantled item shall be reused) laid/beded including screed bed 15mm thick in cement mortar (1:6) on existing lime concrete sufaces of roof,joints grouted flush in cement mortar (1:3) mixed with liquid wpc @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of mes sch part-i (2009) complete all as specified and directed by engr-in-charge. 10 dismantlingof reinforced cement concrete by chiseling (without affecting other portion) of any description and in any position as in roofs, floors (other than ground floor), beams, landing, chajjas and similar suspended work. 11 m&l reinforced cement concrete 1:1 1/2:3 (nominal mix) using 20mm graded stone aggregate as in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately). 12 m & l mild steel tmt bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with ms wire (annealed) not less than 0.90mm dia all as in column, beam etc . 13 m&l for form work to soffits of suspended slabs such as roof slabs,floor slabs,landings and similar work not exc.200 mm thick(horizontal or sloping) rough finish surface of concrete flat all as specified and directed. 14 m&l for precast reinforced cement concrete (1:2:4) type b1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole set in cm (1:6).note :- cost of form work is deemed to be inclusive of unit rate quoted by the contractor & reinforcementshall be measured & paid separately.) 15 taking down chowkatsor frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified. 16 taking down chowkatswith shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) 17 taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and refixing in same opening after necessary easing, adjustments, minor repairs, oiling, adjustment with cutting or fixing plain fillets/planks made from second class hard wood etc to remove gap between floor and shutter complete all as specified and as directed by engineer-in- charge. 18 taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm eachcomplete all as specified and as directed by engineer-in- charge. 19 s&f factory made single extruded wpc (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 45 x 70 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed ss screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 n (face) & 1100 n (edge), minimum compressive strength of 58 n/mm2, modules ofelasticity 900 n/mm2and resistance to spread of flame of class a category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with ms hold fast/ lugs/ss dash fasteners of required dia and length complete as per direction of engineer-in-charge. (m.s. hold fast/ lugs or ss dash fasteners shall be paid for separately). note :- for wpc solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made all as specified and directed . 20 providing and fixing factory made single extruded wpc (wood polymer composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 n (face) & 900 n (edge), minimum compressive strength 50 n/mm2, modulus of elasticity 850 n/mm2 and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant. wpc to be laminated with pvc foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk s.s screws, all as per direction of engineer- in- charge including supply and fixing following items : (a) stainless steel (304 grade) finished butt hinges 100mm - 4 nos. per leaf (b) stainless steel (304 grade) finished square tower bolt 150 mm long - 2nos per leaf (c) stainless steel (304 grade) finished handles 150 mm - 2 nos. per leaf 21 supply and fixingfactory made pressed steel frames of size 125 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , includingbutt hinges suitable nos as directed for each leaf, complete all as specified and as directed by engineer-in- charge. 22 supply and fixingfactory made pressed steel frames of size 105 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , including butt hinges suitable nos as directed for each leaf, complete all as specified and as directed by engineer-in- charge. 23 m&l cement concrete 1:3:6 type c-1 using 20mm graded stone aggregate for filling of pressed steel frame and hold fast blocks etc complete all as specified and directed by engineer - in - charge. 24 s & f factory made plain framed, panelled shutter iind class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm b.w.p. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per is : 1003 (part i), kiln seasoned and chemically pressure treated complete all as specified and directed by engineer - in - charge. 25 s & f factory made 35mm thick iind class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in ssr part – i, section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by engineer - in - charge. 26 s & f100 mm aluminium alloy anodised butt hinges, and fixed with steel scerws for frp doors/pvc door, type b-21complete all as specified and directed by engineer - in - charge. 27 s & f in repair 100 mm mild steel butt hinges, and fixed with steel scerws for wooden doors, complete all as specified and directed by engineer - in - charge.note :- rate deemed including necessary welding etc) 28 s & f tower bolt 200 mm of aluminum complete all as specified and directed by engineer - in - charge. 29 s & f in repair tower bolt 200 mm of aluminum complete all as specified and directed by engineer - in - charge. 30 s & f door handle d type 150 mm of aluminum complete all as specified and directed by engineer - in - charge. 31 s & f in repair door handle d type 150 mm of aluminum complete all as specified and directed by engineer - in - charge. 32 s & f aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed. 33 s & f in replacement aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed. 34 s&f floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. 35 s&f in repairs floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. 36 s & f mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified. 37 s & f in repairs mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified. 38 s& fstainless steel curtain rod 25 mm dia , including fancy type brackets and pair of decorated end knobs (finials), stop roller etc.as per site requirement, fixed to wall with fixing accessories,including taking down old existing curtain rods any description complete all as specified and directed by engr-in-charge. 39 s&f factory made box type steel window with side hung shuters both glazed and gauged, shutter frame 60x25mm erw hollow p section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx70mmx1.60mm thick including fixing glazed portion, iron grills 8mm suare ms barhinges with steel handle and fitting, lugs etc., including one shop coat of primer complete all as specified.(drg no btd889 sheet 1/4 ).note :- (i) wire mesh and glass shall be measured and paid separately under relevent items of sch/boq.(ii)measurement for payment shall be the opening area of the window between inner edges of wall. 40 s&f factory made box type steel window with side hung glazedshutter, frame 60x25mm erw hollow p section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx70mmx1.60mm thick including fixing glazed portion, iron grills 8mm suare ms barhinges with steel handle and fitting, lugs etc., including one shop coat of primer complete all as specified.note :- (i)wire mesh and glass shall be measured and paid separately under relevent items of sch/boq.(ii)measurement for payment shall be the opening area of the window between inner edges of wall. 41 s&f stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as specified. 42 s & f in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as specified. 43 s & f 4 mm thick sheet glass ordinary quality and glazing within square not exceeding 0.50 sqm including aluminium cleat/rubber beading in each pane complete all as specified and directed by engineer - in - charge. 44 supply & fixing aluminium anodisedframes/chowkhats,shutter and like made out of aluminium sectionpowder coated(minimum thickness of powder coating not less than 50 micron) for window, ventilators and aluminium partition with one or more rebates or without rebate including joining cleat for fixing etc., the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawal plug and screw or with fixing clip or with expansion hold plate fasteners. aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required complete all as specified and as directed by engineer-in-charge.. 45 s & f figured glass 4 mm thick pin head type and glazing withnot exceeding 0.50 sqmincluding aluminium cleat/rubber beading in each pan complete all as specified and directed by engineer - in - charge. 46 material and labour for machine cut 16 to 18 mm thick, kota stone slab (size of slab not less than 500x550mm for flooring and in single piece for treads of staircase), laid over and including 20 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) andpolishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by engineer-in-charge. 47 material and labour for machine cut 16-18mm thick, kota stone slab as in skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangularcomplete all as specified and as directed by engineer-in-charge. 48 taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. 49 m & lfor rendering 15mm thik on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement. 50 m & lfor rendering 15mm thick on fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement. 51 m&l rendering10 mm thick in cement mortar 1:3 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement. 52 m&l integal water proofing compound 53 preparation of new plastered surfaces/existing platered surfaces and applyingwall care putty in internal/external walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony/ceilings etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior/exterior painting complete all as specified and directed.note : (i) the prepared surface after wall putty, the contractor will inform to the ge as well as to the engineer-in-charge for site inspection before applying further external finishes. please note that the further external finishes work will start only after approval of the prepared surface from the ge as well as to the engineer-in-charge through site order. 54 preparation of surfaces and applying 02 coats of interior emulsion paint (light shade) @ 12 sq.m/litre/2 coats by using spray gun to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. 55 preparation of surfaces and applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats by by using spray gun to ceiling surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. 56 preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade)@ 5 sq.m/litre/2 coats by using spray gun to external walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. 57 preparation of new/existing plastered surfaces as in ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer-in-charge. 58 preparation of new/existing plastered surfaces as in walls and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer-in-charge. 59 m & l providing two coats of synthetic enamel paint over new steel surfaces and a coat of red oxide primer onincluding preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by engineer -in -charge. 60 m & l providing two coats of synthetic enamel paint over new wooden surface including preparation of surface withprimer all as specified. 61 m&l for preperationof old steel surface and applying two coat of synthetic enamel paint complete all as specified and directed by engineer -in -charge. 62 m&l for preperationof old wooden surface and applying two coat of synthetic enamel paintcomplete all as specified and directed by engineer -in -charge. 63 m&l for shotcreting 25mm thick in rcc columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 kg/cum on m-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc as directed by engineer-in-charge including chipping of unsound /weak concrete material 25 mmaverage thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with dr fixit epoxy zinc primer or equivalent @ 6sqm/ltr at dft of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of engineer-in-charge. 64 m&l hard drawn steel wire fabric not exc 4kg/sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntall as specified & directed by engineer-in-charge. 65 m & l 5mm thick rendering in cement mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cementcomplete all as specified and directed by engineer - in - charge . 66 dismantling structural steel work including doors,gates but excluding framed truss etc. 67 s & f framed work such as grills,cooler stand ,ladder grating and sun shed etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming tofe 410-0 or fe 310-0 all as specified . 68 dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices. 69 s&f glazed ceramic colouredtiles joint free 350x250x7mm/450x350x7mm square or rectanguleras on walls etc set and jointed in neat cement slurry and pointed in whiteor coloured cement to match over and including 10mm thick rendering in cm 1:4 complete all as specified and directed by engr-in-charge. 70 m&l non skid ceramic coloured /printed tiles 7 to 8 mm thick( square / rectangular) area of each tile exc. 0.11 sqm but n. exc, 0.18 sqm in floor and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shadeover and incl 15 mm thick screed bed in cm 1:6 complete all as specified and directed by engr-in-charge. 71 m&l cement concrete type b-0, 1:2:4 using 12.5 mm graded stone aggregate as in floors 25 mm thick for tilesall as specified.& directed by engr -in-charge.. 72 m&l 16-18 mm thick granite (of any type ) work (table rubbed and polished ) in cooking platform and likein cm (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding/moulding of edges. 73 demolitionof cement concrete ( un re-inforced) of any description in ground floor and pavings exc15 cm thickness (below or above gl). 74 material and labour for water proofing treatment to rcc sunken slab and adjoining vertical slab as described following any one method complete as per directions of ge. 75 method 1(a) supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, smart care damp proof 2k, having 100% elongation as per astm d412, resisting 5 bars hydrostatic pressure as per din 1048, reduction to rapid chloride shall be 70 as per din 1048, crack bridging upto 1.2mm as per astm 4548.5 clean all working surface & made free from dirt, grease laitance etc. after inspection for all working area rough surface, cracks & from dirt, grease laitance etc. after inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 cement : 1polymer : 4 sand). making gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 cement : 1 polymer : 4 sand). the coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. the mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(b) bore packing: all the borehole gaps between concrete surface and pvc pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – smart care gp grout having dual shrinkage compensation property. before the bore packing, surface of the pvc pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent. (c) apply12-15mm plaster on slab and vertical surface admixed with smart care vitalia neo @200ml per bag of cement before treatment. 76 method 2(a) supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm dft, having hydrostatic (positive) water pressure resistance (din 1048) is 7. abrasion resistance, cm/km is 0.09 of dr fixit pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. the polyester reinforced coated netof 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer dr fixit pidifin 2k. after removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola onsurrounding wall’s junction and seal the vertical walls. in case of core cutting on the surface, the joint is seal with non-shrink grout.(b) the coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(c) apply12-15mm water proof plaster on slab and vertical surface admixed with dr fixit pidiproof 77 m & l pcc (1:5:10)using 40mm graded burnt bricksaggregate as in foundation filling & mass concrete or as in sunkenfloor complete all as specified & directed by engineer-in-charge 78 dismantling water tanks and removing to store ofexc 500 and nexc 1000 ltr capacity 79 s & f rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in ssr part i of capacity 1000 litres all as specified and directed by engineer - in - charge . 80 s&f in repair 20mm ball brass valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed. 81 s & f in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified . 82 s & f in 25 mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified . 83 s & f in repairs pvc 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of pvc 32mm bore and connection to wc pan complete all as specified. 84 s&f in repair viterous china squating pan orrisa pattern size 580/440mm wash down water closet pan ,white (excluding fixing bolts, flushing cistern and flush pipe) with plastic seat cover. 85 s&f in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe ,anti-syphonage pipe and white closed patern with flat bottom & mild steel cromium plated or aluminium hinging device plasticseat cover complete . 86 s&f repairs vitreous china half stall urinals flat back white minimum with grating and union for discharge pipe ,providing & fixing plugs, bedding urinal against wall in cm 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified. 87 s & f in repairs vitrous china oval wash hand basin white of size 550x400 mm including brackets 300mm long pvc connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etccoloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified. 88 s&f in repair 600mm x 450mm beveled edge mirror of selected quality glass on 6mm thick commercial plywood and fixed wooden plugs with chromium plated brass screw and cup washes fixed in repair. 89 s & f repairs 15 mm bore concealed stop cock cast copper alloy screwed down high pressurewith crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated with long shank and cup (concealled type) 90 s & f in repairs 15mm bore angle cock one waychromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified . 91 s & f in repairs 15 mm bore bib tap fancy type chromium plated with crutch or butterfly handle screwed down ,screwed for iron pipe all as specified. 92 s&f in repairs pillar taps 15mm borefancy type chromium plated cast copper alloywith capstan heads scre-wed down high pressure with or without lettered hot orcold with long screwed shanks and fly nuts screwed for iron pipe . isi marked 93 s&f in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by engr-in-charge. 94 s&fin repair brass chromium plated shower rose 125mm size with swivel joints,any size, incl shower arm fixing to pipe or union complete all as specified and directed by engr-in-charge. 95 s&f in repair pvc connection both side brass unions internal for size 15mm dia and 450mm long all as specified and directed by engineer-in-charge. 96 s&f ewc jet spray complete all as specified and directed. 97 s & f in repairsoap dish approximately size 160 x160x 90 mm and fixed withas chromium plated brass screws complete all as specified and directed by engineer -in -charge. 98 s&f peg set of stainless steel solid body of 125mm to 175 mm having 6 nos hooks fixed with brass chromium plated screws complete in all as specified 99 taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by engr-in-charge. 100 fixing only mild steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified & directed by engineer-in-charge. 101 supply & fixing mild steel tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed complete to wallall as specified & directed by engineer-in-charge. 102 taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store omplete all as specified and directed by engineer -in -charge. 103 supply & fixing of 16mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing omplete all as specified and directed by engineer -in -charge. 104 supply & fixing of 20mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing omplete all as specified and directed by engineer -in -charge. note :-(i) pipes inside the buildings shall be fixed concealed and outside the buildings shall be fixed on the surface along wall with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, as directed by engineer-in-charge.(ii)bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on btd drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. 105 supply & fixing of 25mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing complete all as specified and as directed.note :- (i) pipes inside the buildings shall be fixed concealed and outside thebuildings shall be fixed on the surface along wall with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, as directed by engineer-in-charge.(ii) bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on btd drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. 106 taking up or down steel tubing of 25 to 32 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by engr-in-charge. 107 s & f 40mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by engineer - in - charge. 108 dismantling of cast iron pipes jointed in cement mortar and taking out from trenches walls etc upto 100 mm bore all as specified and directed by engr-in-charge . 109 supply & fixing 110mm bore upvc pipes grade b single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant c complete all as specified and directed by engr-in-charge. 110 supply & fixing 75mm bore upvc pipes grade b single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant complete all as specified and directed by engr-in-charge. 111 supply & fixing upvc junction (double t/socket) grade b equal or unequal suitable for 110mm bore pipe complete all as specified and complete all as specified and directed by engr-in-charge. 112 all as per item no 109 above 113 supply & fixing upvc bends (any radius) grade b suitable for 110mm bore pipe complete all as specified and directed by engr-in-charge. 114 all as per item no 111 above 115 supply & fixing upvc vent cowl grade b suitable for 110mm bore pipe complete all as specified and directed by engr-in-charge. 116 supply & fixing pvc vent cowl grade b suitable for 75 mm bore pipe complete all as specified and directed by engr-in-charge. 117 supply & fixing upvc grade b multi floor trap 110 mm bore and 600mm long with grating including jointing with with pipe joint lubricant complete all as specified and directed by engr-in-charge. 118 supply & fixing upvc grade b multi floor trap 75 mm bore and 600mm long with grating including jointing with with pipe joint lubricant complete all as specified and directed by engr-in-charge. 119 demolition of brick work built in cement mortar including all quoins, arches, pillars etc . 120 m&l for brick work with subclass‘b’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by engineer-in-charge. 121 labour only forbrick work built in cm (1:6) with subclass b bricks, straight or curved on plan exceeding 6m mean radiuswith reusing the old bricks obtained fromitem no 118 . 122 m&l for taking down carefully point wiring complete including fixture and fittings from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc and making good to disturbed area all as specified 123 m&l for point wiring complete with isi marked 1.5 sqmm single core pvc insulated unsheathed cable 1100v grade frls with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories includingpvc rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, ms hooks, ms junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switchs, sockets, fan regulator etc covered with 3 mm thick plastic laminated hylem top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer includingfixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for the following all as specified 124 (a)one light point/fan point/exhaust controlled byone way switch 125 (b)one light point controlled by one two way switch 126 (c)one 5 pin socket out let 5 amps on the same board with other switches 127 (d)one 5 pin, 5a switch socket outlet point on independent board with other switches. 128 all as per item no. 02 here-in-before but with 2.5 sqmm cable for 1no 16 amps socket outlet point on independent board including 2.5 sqmm pvc insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified 129 s&f piano type switch single pole 1 way 5/6 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 130 s&f socket two in one 6/5 pin 5 amps230 volt ac supply complete all as specified and directed by engr-in-charge. 131 s&f piano type switch single pole 1 way 15/16 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 132 s&f piano flush type switch single pole 2 way 15 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 133 s&f socket two in one 6/5 pin 15/16 amps230 volt ac supply complete all as specified and directed by engr-in-charge. 134 s&f ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / pvc / polycarbonate isolated body complete all as specified and directed by engr-in-charge. 135 s & f stepped type electronic fan regulator flush type on the existingphenolic laminated sheet etc. as reqd complete all as pecified and directed. 136 s&f lamp holder, pvc/polycarbonate type with back plate suitable for batten fittings with led bulb 09 watt complete all as specified 137 supply and fixing led lights fitting 20 w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 138 supply and fixing led light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete. 139 supply and fixing led street light fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete. 140 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amps capacity complete all as specified and directed by engr-in-charge. 141 s&f sheet metal enclosure for vtpn dbs 415 volts 08 way with 200 amps rated bus bar neautral link, earth bar double door with mccb as incomer complete all as specified 142 s&f sheet metal enclosure for vtpn dbs 415 volts 04 way with 200 amps rated bus bar neautral link, earth bar double door with mcb tpn as incomer complete all as specified and directed by engr-in-charge. 143 s&f sheet metal enclosure for dbs spn 230 volts 12 way with 200 amps rated bus bar neautral link, earth bar double door complete all as specified and directed by engr-in-charge. 144 supply and fixing 415v 16 ka 415 volts mccb of cap 100 amps following poles and current carrying capacity in the db complete with connection testing and commissioning. 145 supply and fixing 415v 10ka b curve miniature circuit breaker (mcb) tpn/4p of capacity 40 to 100 amps poles and current carrying capacity in the db complete with connection testing and commissioning. 146 supply and fixing 240v, 10 ka b curve miniature circuit breaker (mcb) of single poles and current carrying capacity 6 to 32 amp, in the mcb db complete with connection testing and commissioning complete all as specified and directed by engr-in-charge. 147 supply and fixing amp rating 240v, 10ka c curve miniature circuit breaker (mcb) of spn 40 to 63 amp and current carrying capacity in the mcb db complete with connection testing and commissioning complete all as specified 148 m&l forsubmain wiring comprising single core , 2 runs of 2.5 sqmm nominal cross sectional areamulti stranded copper conductor cable, pvc insulated unsheathed 1100 volts gradedrawing in and including appropriate dia. in surface/recessed pvc conduit and its fittings completeincluding provision of 1x2.5 sqmm nominal cross sectional areamulti stranded copper conductor cable, pvc insulated unsheathed 1100 volts grade as earthwire and using color code as per is and specified and making good all disturbed work to match the existing complete incl taking down old unsv sub main complete all as specified and directed by engr-in-charge. note :- (i)extra length of cables/ wire required for connection to mcbs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly.(ii) two run of wire, one run of earth wire and conduct shall be measured as one unit. 149 all as per item no 142 abovebut for single core , 2 runs of 4.0 sqmm nominal cross sectional area including provision of 1x4.0 sqmm nominal cross sectional area complete all as specified and directed by engr-in-charge. 150 all as per item no 142 above but for single core , 2 runs of 6.0 sqmm nominal cross sectional area including provision of 1x 6.0 sqmm nominal cross sectional area complete all as specified and directed by engr-in-charge. 151 m&l for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal gl connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washersand earth strip protected by 15 mm dia gi pipe medium grade and connected to main distribution board panel/earthing test point all as shown on electrical plate no.3 of ssr part i and all as specified including testing on completionincluding taking down old unserviceable earthing any type complete all as specified and directed by engr-in-charge. note :-gi wire 4mm dia including test point terminal box include in the quoted rate.
  • View Tender
  • Document
  • Bid Support
4 Housing Urban And Rular Development
image image
Government Departments
TRN :49054357 |  29 May, 2025
Tender Value : 3.08 Crore
 Aurangabad - Bihar
Tender for tender for special repair & maintenance work at jnv baroon. - structural repair & retrofitting 3 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 4 50 mm average thickness 5 25 mm average thickness 6 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 7 bars upto 12 mm diameter 8 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 9 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 10 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in grade m 25 with cement content not less than 330 kg per cum 12 50mm thick in grade m 25 with cement content not less than 330 kg per cum 13 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 14 repairs to roof 15 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 16 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 17 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 18 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 19 asbestos cement sheet 20 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 21 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 22 providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m* 23 providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross t of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer-in-charge. 24 gi metal ceiling lay in plain tegular edge global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of g i sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 25 repair to plaster and plinth protection 26 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 27 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 28 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 29 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 30 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 31 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 32 with cement mortar 1:4 (1cement: 4 coarse sand) 33 12mm cement plaster of mix : 34 1:6 (1 cement : 6 course sand) 35 6mm cement plaster to ceiling of mix : 36 1:3 ( 1 cement : 3 fine sand) 37 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 38 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 39 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 40 old work (one or more coats) 41 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 42 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 43 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 44 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 45 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 46 repairs to door / windows 47 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 48 of area 3 sq. metres and below 49 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 50 of area 3 sq. metres and below 51 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 52 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 53 renewal of old putty of glass panes (length) 54 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 55 using flats 30x6mm for diagonal braces and central cross piece 56 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 57 35 mm thick including isi marked stainless steel butt hinges with necessary screws 58 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 59 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 60 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 61 300 mm weighing not less than 200gms. 62 250 mm weighing not less than 150gms. 63 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 64 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 65 300 x 10mm 66 150 x 10mm 67 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 68 with 12 mm mild steel u beading 69 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 70 125 mm 71 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 72 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 73 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 74 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 75 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 76 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 77 4.0 mm thick glass panes 78 applying priming coat : 79 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 80 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 81 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 82 two or more coats on new work 83 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 84 one or more coats on old work 85 flooring 86 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 87 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 88 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 89 25 mm thick 90 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 91 25mm wooden planking, tongued and grooved in flooring including fixing with iron screws complete with : second class teak wood 92 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 93 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 94 miscellaneous 95 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 96 in cement mortar 97 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 98 cement mortar 1:6 (1 cement : 6 coarse sand) 99 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 100 cement mortar 1:4 (1 cement :4 coarse sand 101 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 102 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 103 providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia m.s. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with m.s. tubes, m.s. tube challies, m.s. clamps and m.s. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .the scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of engineerin-charge .the elevational area of the scaffolding shall be measured for payment purpose .the payment will be made once irrespective of duration of scaffolding.note: - this item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 104 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 105 75 to 80 mm dia pipe 106 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 107 110 mm diameter 108 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 109 a) coupler 110 110 mm 111 b) bend 87.5° 112 110 mm bend 113 electrical work 114 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 115 group c 116 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 117 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 118 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 119 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 120 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 121 2 x 1.5 sq. mm 122 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 123 25 mm 124 32 mm 125 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 126 100 mm x 100 mm x 60 mm deep 127 150 mm x 75 mm x 60 mm deep 128 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 129 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 130 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 131 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 132 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 133 6 way, double door 134 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 135 4 way (4 + 12), double door 136 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 137 single pole 138 single pole and neutral 139 triple pole 140 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 141 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 142 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 143 upto 450 mm sweep 144 supply of 15w surface mounted round led with all accessories as per standard item.. 145 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 146 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 147 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 148 supply of 30w led recess mounted fixturemake-philips cat no.rc380b led30s-6500 l60w60 psd od s1 or equivalent. 149 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 150 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 151 450 mm sweep 1400 rpm 152 staff qtrs type-iii . (24 nos. i.e. 6 blocks of four unit each) g+1 153 structural repair & retrofitting 154 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 155 50 mm average thickness 156 25 mm average thickness 157 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 158 bars upto 12 mm diameter 159 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 160 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 161 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 162 25mm thick in grade m 25 with cement content not less than 330 kg per cum 163 50mm thick in grade m 25 with cement content not less than 330 kg per cum 164 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 165 repairs to roof 166 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 167 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 168 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 169 repair to toilets 170 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 171 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 172 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 173 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 174 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 175 providing and filling of cinder in sunken portions. 176 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 177 75 to 80 mm dia pipe 178 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 179 15 mm to 40 mm nominal bore 180 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 181 up to 150 mm diameter 182 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 183 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 184 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 185 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 186 up to 150 mm diameter 187 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 188 rectangular manhole 90x80 cm and 45 cm deep 189 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 190 110 mm diameter 191 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 192 a) coupler 193 110 mm 194 b) bend 87.5° 195 110 mm bend 196 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 197 75 mm diameter pipes 198 100 mm diameter pipes 199 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 200 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 201 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 202 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 203 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 204 kitchen sink without drain board 205 610x510 mm bowl depth 200 mm 206 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 207 a) 32mm dia (for wash basin) 208 b) 40mm dia (for sink and urinal) 209 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 210 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 211 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 212 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 213 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 214 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 215 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 216 110 mm dia (wall thickness - 3.2 to 3.8 mm) 217 75 mm dia (wall thickness - 3.2 to 3.8 mm) 218 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 219 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 220 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 221 p-trap type floor trap 110 x 75 mm 222 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 223 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 224 providing and fixing 100 mm sand cast iron grating for gully trap. 225 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 226 providing & fixing soil, waste and vent pipes. 227 a) 100mm dia centrifugally cast iron s & s pipe. 228 b)75mm dia centrifugally cast iron s & s pipe. 229 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 230 a) for 100mm dia pipe. 231 b) for 75mm dia pipe. 232 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 233 a) 100mm 234 sand cast iron s&s as per is - 3989 235 b) 75mm 236 sand cast iron s&s as per is- 3989 237 providing and fixing plaincast iron s & s sanitary bend. 238 a) 100mm 239 sand cast iron s&s as per is - 1729 240 b) 75mm 241 sand cast iron s&s as per is - 3989 242 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 243 a) 100x100x100mm 244 b) 75x75x75mm 245 providing and fixingcast iron terminal guard. 246 a) 100mm 247 b) 75mm 248 providing & fixingcast iron coller. 249 a)100 mm 250 sand cast iron s&s as per is - 3989 251 b)75mm dia. 252 sand cast iron s&s as per is - 3989 253 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 254 a) 100mm 255 b) 75mm 256 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 257 a) 100mm inlet & 75mm outlet. 258 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 259 15 mm nominal outer dia pipes 260 20 mm nominal outer dia pipes 261 25 mm nominal outer dia pipes 262 32 mm nominal outer dia pipes 263 providing and fixing brass stop cock of approved quality. 264 15 mm nominal bore 265 providing and fixing gun metal gate valve with wheel of approved quality. 266 a) 25mm dia nominal bore 267 b) 32mm dia nominal bore 268 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 269 a) 25mm. nominal bore 270 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 271 a) 15mm nominal bore 272 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 273 a) 15mm nominal bore 274 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 275 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 276 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 277 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 278 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 279 providing & fixing cp brass bib cock of approved quality conforming to is 8931 280 a) 15mm nominal bore 281 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 282 a) 15mm nominal bore 283 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 284 a) 15mm nominal bore 285 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 286 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 287 25mm nominal bore, weighing not less than 62 gms 288 cutting holes up to 30x30 cm in walls including making good the same: 289 with common burnt clay f.p.s. (non modular) bricks 290 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 291 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 292 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 293 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 294 repair to plaster and plinth protection 295 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 296 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 297 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 298 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 299 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 300 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 301 with cement mortar 1:4 (1cement: 4 coarse sand) 302 12mm cement plaster of mix : 303 1:6 (1 cement : 6 course sand) 304 6mm cement plaster to ceiling of mix : 305 1:3 ( 1 cement : 3 fine sand) 306 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 307 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 308 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 309 old work (one or more coats) 310 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 311 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 312 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 313 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 314 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 315 repairs to door / windows 316 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 317 of area 3 sq. metres and below 318 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 319 of area 3 sq. metres and below 320 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 321 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 322 renewal of old putty of glass panes (length) 323 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 324 35 mm thick including isi marked stainless steel butt hinges with necessary screws 325 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 326 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 327 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 328 300 mm weighing not less than 200gms. 329 250 mm weighing not less than 150gms. 330 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 331 100x58x1.90 mm 332 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 333 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 334 300 x 10mm 335 150 x 10mm 336 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 337 providing and fixing to existing door frames. 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 338 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 339 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 340 with isi marked stainless steel butt hinges of required size 341 kiln seasoned and chemically treated hollock wood 342 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 343 with 12 mm mild steel u beading 344 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 345 125 mm 346 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 347 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 348 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 349 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 350 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 351 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 352 4.0 mm thick glass panes 353 applying priming coat : 354 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 355 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 356 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 357 two or more coats on new work 358 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 359 one or more coats on old work 360 flooring 361 miscellaneous 362 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 363 cement mortar 1:6 (1 cement : 6 coarse sand) 364 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 365 cement mortar 1:4 (1 cement :4 coarse sand 366 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 367 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 368 electrical work 369 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 370 group b 371 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 372 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 373 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 374 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 375 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 376 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 377 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 378 group b 379 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 380 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 381 2 x 1.5 sq. mm 382 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 383 25 mm 384 32 mm 385 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 386 100 mm x 100 mm x 60 mm deep 387 150 mm x 75 mm x 60 mm deep 388 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 389 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 390 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 391 s/f light plug point modular type accessories :- 392 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 393 s/f power plug point modular type accessories :- 394 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 395 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 396 supplying and fixing brass batten/ angle holder including connection etc. as required. 397 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 398 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 399 6 way, double door 400 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 401 4 way (4 + 12), double door 402 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 403 single pole 404 single pole and neutral 405 triple pole 406 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 407 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 408 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 409 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 410 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 411 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 412 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 413 supply of 15w surface mounted round led with all accessories as per standard item.. 414 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 415 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 416 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 417 cost of staff qtrs type-iii . (2 blocks of 2 unit each) g 418 structural repair & retrofitting 419 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 420 50 mm average thickness 421 25 mm average thickness 422 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 423 bars upto 12 mm diameter 424 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 425 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 426 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 427 25mm thick in grade m 25 with cement content not less than 330 kg per cum 428 50mm thick in grade m 25 with cement content not less than 330 kg per cum 429 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 430 repairs to roof 431 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 432 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 433 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 434 repair to toilets 435 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 436 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 437 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 438 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. size of tile 600 x 600 mm 439 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 440 75 to 80 mm dia pipe 441 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 442 15 mm to 40 mm nominal bore 443 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 444 up to 150 mm diameter 445 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 446 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 447 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 448 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 449 up to 150 mm diameter 450 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 451 rectangular manhole 90x80 cm and 45 cm deep 452 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 453 110 mm diameter 454 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 455 a) coupler 456 110 mm 457 b) bend 87.5° 458 110 mm bend 459 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 460 75 mm diameter pipes 461 100 mm diameter pipes 462 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 463 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 464 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 465 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 466 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 467 kitchen sink without drain board 468 610x510 mm bowl depth 200 mm 469 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 470 a) 32mm dia (for wash basin) 471 b) 40mm dia (for sink and urinal) 472 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 473 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 474 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 475 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 476 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 477 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 478 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 479 110 mm dia (wall thickness - 3.2 to 3.8 mm) 480 75 mm dia (wall thickness - 3.2 to 3.8 mm) 481 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 482 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 483 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 484 p-trap type floor trap 110 x 75 mm 485 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 486 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 487 providing and fixing 100 mm sand cast iron grating for gully trap. 488 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 489 providing & fixing soil, waste and vent pipes. 490 a) 100mm dia centrifugally cast iron s & s pipe. 491 b)75mm dia centrifugally cast iron s & s pipe. 492 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 493 a) for 100mm dia pipe. 494 b) for 75mm dia pipe. 495 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 496 a) 100mm 497 sand cast iron s&s as per is - 3989 498 b) 75mm 499 sand cast iron s&s as per is- 3989 500 providing and fixing plaincast iron s & s sanitary bend. 501 a) 100mm 502 sand cast iron s&s as per is - 1729 503 b) 75mm 504 sand cast iron s&s as per is - 3989 505 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 506 a) 100x100x100mm 507 b) 75x75x75mm 508 providing and fixingcast iron terminal guard. 509 a) 100mm 510 b) 75mm 511 providing & fixingcast iron coller. 512 a)100 mm 513 sand cast iron s&s as per is - 3989 514 b)75mm dia. 515 sand cast iron s&s as per is - 3989 516 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 517 a) 100mm 518 b) 75mm 519 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 520 a) 100mm inlet & 75mm outlet. 521 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 522 15 mm nominal outer dia pipes 523 20 mm nominal outer dia pipes 524 25 mm nominal outer dia pipes 525 32 mm nominal outer dia pipes 526 providing and fixing brass stop cock of approved quality. 527 15 mm nominal bore 528 providing and fixing gun metal gate valve with wheel of approved quality. 529 a) 25mm dia nominal bore 530 b) 32mm dia nominal bore 531 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 532 a) 25mm. nominal bore 533 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 534 a) 15mm nominal bore 535 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 536 a) 15mm nominal bore 537 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 538 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 539 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 540 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 541 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 542 providing & fixing cp brass bib cock of approved quality conforming to is 8931 543 a) 15mm nominal bore 544 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 545 a) 15mm nominal bore 546 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 547 a) 15mm nominal bore 548 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 549 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 550 25mm nominal bore, weighing not less than 62 gms 551 cutting holes up to 30x30 cm in walls including making good the same: 552 with common burnt clay f.p.s. (non modular) bricks 553 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 554 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 555 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 556 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 557 repair to plaster and plinth protection 558 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 559 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 560 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 561 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 562 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 563 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 564 with cement mortar 1:4 (1cement: 4 coarse sand) 565 12mm cement plaster of mix : 566 1:6 (1 cement : 6 course sand) 567 6mm cement plaster to ceiling of mix : 568 1:3 ( 1 cement : 3 fine sand) 569 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 570 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 571 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 572 old work (one or more coats) 573 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 574 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 575 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 576 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 577 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 578 repairs to door / windows 579 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 580 of area 3 sq. metres and below 581 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 582 of area 3 sq. metres and below 583 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 584 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 585 renewal of old putty of glass panes (length) 586 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 587 35 mm thick including isi marked stainless steel butt hinges with necessary screws 588 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 589 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 590 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 591 300 mm weighing not less than 200gms. 592 250 mm weighing not less than 150gms. 593 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 594 100x58x1.90 mm 595 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 596 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 597 300 x 10mm 598 150 x 10mm 599 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 600 providing and fixing to existing door frames. 601 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 602 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 603 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 604 with isi marked stainless steel butt hinges of required size 605 kiln seasoned and chemically treated hollock wood 606 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 607 with 12 mm mild steel u beading 608 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 609 125 mm 610 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 611 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 612 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 613 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 614 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 615 4.0 mm thick glass panes 616 applying priming coat : 617 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 618 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 619 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 620 two or more coats on new work 621 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 622 one or more coats on old work 623 flooring 624 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 625 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 626 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 627 25 mm thick 628 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 629 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 630 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 631 miscellaneous 632 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 633 cement mortar 1:6 (1 cement : 6 coarse sand) 634 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 635 cement mortar 1:4 (1 cement :4 coarse sand 636 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 637 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 638 electrical work of type-iii (g) 639 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 640 group b 641 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 642 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 643 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 644 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 645 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 646 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 647 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 648 group b 649 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 650 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 651 2 x 1.5 sq. mm 652 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 653 25 mm 654 32 mm 655 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 656 100 mm x 100 mm x 60 mm deep 657 150 mm x 75 mm x 60 mm deep 658 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 659 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 660 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 661 s/f light plug point modular type accessories :- 662 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 663 s/f power plug point modular type accessories :- 664 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 665 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 666 supplying and fixing brass batten/ angle holder including connection etc. as required. 667 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 668 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 669 6 way, double door 670 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 671 4 way (4 + 12), double door 672 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 673 single pole 674 single pole and neutral 675 triple pole 676 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 677 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 678 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 679 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 680 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 681 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 682 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 683 supply of 15w surface mounted round led with all accessories as per standard item.. 684 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 685 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 686 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 687 type - 4 688 structural repair & retrofitting 689 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 690 50 mm average thickness 691 25 mm average thickness 692 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 693 bars upto 12 mm diameter 694 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 695 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 696 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 697 25mm thick in grade m 25 with cement content not less than 330 kg per cum 698 50mm thick in grade m 25 with cement content not less than 330 kg per cum 699 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 700 repairs to roof 701 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 702 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 703 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 704 repair to toilets 705 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 706 for thickness of tiles 10 mm to 25 mm 707 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. glazed vitrified floor tiles polished finish of sizesize of tile 600 x 600 mm 708 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 709 75 to 80 mm dia pipe 710 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 711 15 mm to 40 mm nominal bore 712 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 713 up to 150 mm diameter 714 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 715 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 716 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 717 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 718 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 719 up to 150 mm diameter 720 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 721 rectangular manhole 90x80 cm and 45 cm deep 722 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 723 110 mm diameter 724 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 725 a) coupler 726 110 mm 727 b) bend 87.5° 728 110 mm bend 729 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 730 75 mm diameter pipes 731 100 mm diameter pipes 732 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 733 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 734 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : 735 w.c. pan with isi marked white solid plastic seat and lid 736 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 737 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 738 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 739 kitchen sink without drain board 740 610x510 mm bowl depth 200 mm 741 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 742 a) 32mm dia (for wash basin) 743 b) 40mm dia (for sink and urinal) 744 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 745 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 746 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 747 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 748 providing & fixing c.p. brass waste coupling for pvc waste pipe. 749 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 750 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 751 110 mm dia (wall thickness - 3.2 to 3.8 mm) 752 75 mm dia (wall thickness - 3.2 to 3.8 mm) 753 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 754 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 755 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 756 p-trap type floor trap 110 x 75 mm 757 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 758 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 759 providing and fixing 100 mm sand cast iron grating for gully trap. 760 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 761 providing & fixing soil, waste and vent pipes. 762 a) 100mm dia centrifugally cast iron s & s pipe. 763 b)75mm dia centrifugally cast iron s & s pipe. 764 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 765 a) for 100mm dia pipe. 766 b) for 75mm dia pipe. 767 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 768 a) 100mm 769 sand cast iron s&s as per is - 3989 770 b) 75mm 771 sand cast iron s&s as per is- 3989 772 providing and fixing plaincast iron s & s sanitary bend. 773 a) 100mm 774 sand cast iron s&s as per is - 1729 775 b) 75mm 776 sand cast iron s&s as per is - 3989 777 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 778 a) 100x100x100mm 779 b) 75x75x75mm 780 providing and fixingcast iron terminal guard. 781 a) 100mm 782 b) 75mm 783 providing & fixingcast iron coller. 784 a)100 mm 785 sand cast iron s&s as per is - 3989 786 b)75mm dia. 787 sand cast iron s&s as per is - 3989 788 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 789 a) 100mm 790 b) 75mm 791 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 792 a) 100mm inlet & 75mm outlet. 793 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 794 15 mm nominal outer dia pipes 795 20 mm nominal outer dia pipes 796 25 mm nominal outer dia pipes 797 32 mm nominal outer dia pipes 798 providing and fixing brass stop cock of approved quality. 799 15 mm nominal bore 800 providing and fixing gun metal gate valve with wheel of approved quality. 801 a) 25mm dia nominal bore 802 b) 32mm dia nominal bore 803 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 804 a) 25mm. nominal bore 805 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 806 a) 15mm nominal bore 807 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 808 a) 15mm nominal bore 809 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 810 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 811 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 812 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 813 providing & fixing cp brass bib cock of approved quality conforming to is 8931 814 a) 15mm nominal bore 815 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 816 a) 15mm nominal bore 817 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 818 a) 15mm nominal bore 819 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 820 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 821 25mm nominal bore, weighing not less than 62 gms 822 cutting holes up to 30x30 cm in walls including making good the same: 823 with common burnt clay f.p.s. (non modular) bricks 824 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 825 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 826 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 827 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 828 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 829 repair to plaster and plinth protection 830 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 831 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 832 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 833 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 834 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 835 with cement mortar 1:4 (1cement: 4 coarse sand) 836 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 837 15mm cement plaster on rough side of single or half brick wall of mix 838 1:6 (1 cement : 6 course sand) 839 6mm cement plaster to ceiling of mix : 840 1:3 ( 1 cement : 3 fine sand) 841 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 842 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 843 distempering with 1st quality acrylic distemper (ready made) having voc content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 844 one or more coats on old work 845 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 846 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 847 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 848 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 849 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 850 repairs to door / windows 851 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 852 of area 3 sq. metres and below 853 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 854 of area 3 sq. metres and below 855 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 856 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 857 renewal of old putty of glass panes (length) 858 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 859 35 mm thick including isi marked stainless steel butt hinges with necessary screws 860 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 861 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete fixed to steel windows by welding 862 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 863 300 mm weighing not less than 200gms. 864 250 mm weighing not less than 150gms. 865 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 866 100x58x1.90 mm 867 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 868 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 869 300 x 10mm 870 150 x 10mm 871 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 872 125 mm 873 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 874 twin rubber stopper 875 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 876 providing and fixing to existing door frames. 877 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 878 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 879 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 880 with isi marked stainless steel butt hinges of required size 881 kiln seasoned and chemically treated hollock wood 882 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 883 with 12 mm mild steel u beading 884 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 885 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 886 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 887 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 888 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 889 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 890 4.0 mm thick glass panes 891 applying priming coat : 892 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 893 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 894 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 895 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 896 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 897 one or more coats on old work 898 repairs to flooring 899 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 900 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 901 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 902 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 903 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 904 25 mm thick 905 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 906 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 907 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 908 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 909 miscellaneous 910 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 911 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 912 cement mortar 1:6 (1 cement : 6 coarse sand) 913 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 914 cement mortar 1:4 (1 cement :4 coarse sand 915 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 916 electrical work of guest house 917 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 918 group b 919 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 920 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 921 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 922 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 923 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 924 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 925 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 926 group b 927 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 928 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 929 2 x 1.5 sq. mm 930 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 931 25 mm 932 32 mm 933 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 934 100 mm x 100 mm x 60 mm deep 935 150 mm x 75 mm x 60 mm deep 936 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 937 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 938 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 939 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 940 supplying and fixing brass batten/ angle holder including connection etc. as required. 941 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 942 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 943 6 way, double door 944 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 945 4 way (4 + 12), double door 946 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 947 single pole 948 single pole and neutral 949 triple pole 950 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 951 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 952 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 953 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 954 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 955 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 956 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 957 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 958 upto 450 mm sweep 959 supply of 15w surface mounted round led with all accessories as per standard item.. 960 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 961 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 962 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 963 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 964 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 965 300 mm sweep 1300 rpm 966 guest house 967 structural repair & retrofitting 968 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 969 50 mm average thickness 970 25 mm average thickness 971 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 972 bars upto 12 mm diameter 973 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 974 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 975 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 976 25mm thick in grade m 25 with cement content not less than 330 kg per cum 977 50mm thick in grade m 25 with cement content not less than 330 kg per cum 978 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 979 repairs to roof 980 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete. tear strength in longitudinal and transverse direction as 60/80n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick: 981 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 982 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 983 repair to toilets 984 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 985 for thickness of tiles 10 mm to 25 mm 986 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. glazed vitrified floor tiles polished finish of size size of tile 600 x 600 mm 987 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 988 75 to 80 mm dia pipe 989 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 990 15 mm to 40 mm nominal bore 991 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 992 up to 150 mm diameter 993 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 994 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 995 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 996 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 997 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 998 up to 150 mm diameter 999 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1000 rectangular manhole 90x80 cm and 45 cm deep 1001 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1002 110 mm diameter 1003 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1004 a) coupler 1005 110 mm 1006 b) bend 87.5° 1007 110 mm bend 1008 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1009 75 mm diameter pipes 1010 100 mm diameter pipes 1011 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1012 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1013 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1014 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1015 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1016 kitchen sink without drain board 1017 610x510 mm bowl depth 200 mm 1018 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1019 a) 32mm dia (for wash basin) 1020 b) 40mm dia (for sink and urinal) 1021 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1022 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1023 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1024 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1025 providing & fixing c.p. brass waste coupling for pvc waste pipe. 1026 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1027 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1028 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1029 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1030 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1031 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1032 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1033 p-trap type floor trap 110 x 75 mm 1034 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1035 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1036 providing and fixing 100 mm sand cast iron grating for gully trap. 1037 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1038 providing & fixing soil, waste and vent pipes. 1039 a) 100mm dia centrifugally cast iron s & s pipe. 1040 b)75mm dia centrifugally cast iron s & s pipe. 1041 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1042 a) for 100mm dia pipe. 1043 b) for 75mm dia pipe. 1044 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1045 a) 100mm 1046 sand cast iron s&s as per is - 3989 1047 b) 75mm 1048 sand cast iron s&s as per is- 3989 1049 providing and fixing plaincast iron s & s sanitary bend. 1050 a) 100mm 1051 sand cast iron s&s as per is - 1729 1052 b) 75mm 1053 sand cast iron s&s as per is - 3989 1054 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1055 a) 100x100x100mm 1056 b) 75x75x75mm 1057 providing and fixingcast iron terminal guard. 1058 a) 100mm 1059 b) 75mm 1060 providing & fixingcast iron coller. 1061 a)100 mm 1062 sand cast iron s&s as per is - 3989 1063 b)75mm dia. 1064 sand cast iron s&s as per is - 3989 1065 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1066 a) 100mm 1067 b) 75mm 1068 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1069 a) 100mm inlet & 75mm outlet. 1070 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1071 15 mm nominal outer dia pipes 1072 20 mm nominal outer dia pipes 1073 25 mm nominal outer dia pipes 1074 32 mm nominal outer dia pipes 1075 providing and fixing brass stop cock of approved quality. 1076 15 mm nominal bore 1077 providing and fixing gun metal gate valve with wheel of approved quality. 1078 a) 25mm dia nominal bore 1079 b) 32mm dia nominal bore 1080 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1081 a) 25mm. nominal bore 1082 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1083 a) 15mm nominal bore 1084 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1085 a) 15mm nominal bore 1086 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1087 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1088 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1089 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1090 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1091 a) 15mm nominal bore 1092 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1093 a) 15mm nominal bore 1094 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1095 a) 15mm nominal bore 1096 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1097 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1098 25mm nominal bore, weighing not less than 62 gms 1099 cutting holes up to 30x30 cm in walls including making good the same: 1100 with common burnt clay f.p.s. (non modular) bricks 1101 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1102 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1103 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1104 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1105 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1106 repair to plaster and plinth protection 1107 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1108 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1109 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1110 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1111 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1112 with cement mortar 1:4 (1cement: 4 coarse sand) 1113 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1114 15mm cement plaster on rough side of single or half brick wall of mix 1115 1:6 (1 cement : 6 course sand) 1116 6mm cement plaster to ceiling of mix : 1117 1:3 ( 1 cement : 3 fine sand) 1118 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1119 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1120 distempering with 1st quality acrylic distemper (ready made) having voc content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 1121 one or more coats on old work 1122 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1123 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1124 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1125 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1126 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1127 repairs to door / windows 1128 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1129 of area 3 sq. metres and below 1130 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1131 of area 3 sq. metres and below 1132 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1133 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1134 renewal of old putty of glass panes (length) 1135 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1136 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1137 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1138 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete fixed to steel windows by welding 1139 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1140 300 mm weighing not less than 200gms. 1141 250 mm weighing not less than 150gms. 1142 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1143 100x58x1.90 mm 1144 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1145 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1146 300 x 10mm 1147 150 x 10mm 1148 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1149 125 mm 1150 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 1151 twin rubber stopper 1152 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 1153 providing and fixing to existing door frames. 1154 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1155 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1156 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1157 with isi marked stainless steel butt hinges of required size 1158 kiln seasoned and chemically treated hollock wood 1159 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1160 with 12 mm mild steel u beading 1161 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1162 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1163 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1164 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1165 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1166 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1167 4.0 mm thick glass panes 1168 applying priming coat : 1169 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 1170 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1171 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1172 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 1173 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1174 one or more coats on old work 1175 repairs to flooring 1176 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1177 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1178 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1179 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 1180 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1181 25 mm thick 1182 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1183 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1184 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 1185 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 1186 miscellaneous 1187 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1188 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1189 cement mortar 1:6 (1 cement : 6 coarse sand) 1190 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1191 cement mortar 1:4 (1 cement :4 coarse sand 1192 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1193 electrical work of guest house 1194 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1195 group b 1196 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1197 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1198 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1199 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1200 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1201 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1202 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1203 group b 1204 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1205 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1206 2 x 1.5 sq. mm 1207 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1208 25 mm 1209 32 mm 1210 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1211 100 mm x 100 mm x 60 mm deep 1212 150 mm x 75 mm x 60 mm deep 1213 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1214 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1215 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1216 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1217 supplying and fixing brass batten/ angle holder including connection etc. as required. 1218 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1219 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1220 6 way, double door 1221 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1222 4 way (4 + 12), double door 1223 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1224 single pole 1225 single pole and neutral 1226 triple pole 1227 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1228 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1229 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1230 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1231 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1232 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1233 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1234 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1235 upto 450 mm sweep 1236 supply of 15w surface mounted round led with all accessories as per standard item.. 1237 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1238 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1239 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1240 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 1241 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 1242 300 mm sweep 1300 rpm 1243 staff qtrs type-ii . 1244 structural repair & retrofitting 1245 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1246 50 mm average thickness 1247 25 mm average thickness 1248 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1249 bars upto 12 mm diameter 1250 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1251 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1252 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1253 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1254 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1255 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 1256 repairs to roof 1257 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1258 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1259 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1260 repair to toilets 1261 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1262 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1263 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1264 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. glazed vitrified floor tiles polished finish of size size of tile 600 x 600 mm 1265 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1266 75 to 80 mm dia pipe 1267 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1268 15 mm to 40 mm nominal bore 1269 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1270 up to 150 mm diameter 1271 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1272 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1273 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1274 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1275 up to 150 mm diameter 1276 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1277 rectangular manhole 90x80 cm and 45 cm deep 1278 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1279 110 mm diameter 1280 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1281 a) coupler 1282 110 mm 1283 b) bend 87.5° 1284 110 mm bend 1285 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1286 75 mm diameter pipes 1287 100 mm diameter pipes 1288 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1289 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1290 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1291 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1292 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1293 kitchen sink without drain board 1294 610x510 mm bowl depth 200 mm 1295 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1296 a) 32mm dia (for wash basin) 1297 b) 40mm dia (for sink and urinal) 1298 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1299 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1300 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1301 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1302 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1303 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1304 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1305 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1306 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1307 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1308 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1309 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1310 p-trap type floor trap 110 x 75 mm 1311 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1312 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1313 providing and fixing 100 mm sand cast iron grating for gully trap. 1314 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1315 providing & fixing soil, waste and vent pipes. 1316 a) 100mm dia centrifugally cast iron s & s pipe. 1317 b)75mm dia centrifugally cast iron s & s pipe. 1318 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1319 a) for 100mm dia pipe. 1320 b) for 75mm dia pipe. 1321 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1322 a) 100mm 1323 sand cast iron s&s as per is - 3989 1324 b) 75mm 1325 sand cast iron s&s as per is- 3989 1326 providing and fixing plaincast iron s & s sanitary bend. 1327 a) 100mm 1328 sand cast iron s&s as per is - 1729 1329 b) 75mm 1330 sand cast iron s&s as per is - 3989 1331 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1332 a) 100x100x100mm 1333 b) 75x75x75mm 1334 providing and fixingcast iron terminal guard. 1335 a) 100mm 1336 b) 75mm 1337 providing & fixingcast iron coller. 1338 a)100 mm 1339 sand cast iron s&s as per is - 3989 1340 b)75mm dia. 1341 sand cast iron s&s as per is - 3989 1342 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1343 a) 100mm 1344 b) 75mm 1345 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1346 a) 100mm inlet & 75mm outlet. 1347 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1348 15 mm nominal outer dia pipes 1349 20 mm nominal outer dia pipes 1350 25 mm nominal outer dia pipes 1351 32 mm nominal outer dia pipes 1352 providing and fixing brass stop cock of approved quality. 1353 15 mm nominal bore 1354 providing and fixing gun metal gate valve with wheel of approved quality. 1355 a) 25mm dia nominal bore 1356 b) 32mm dia nominal bore 1357 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1358 a) 25mm. nominal bore 1359 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1360 a) 15mm nominal bore 1361 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1362 a) 15mm nominal bore 1363 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1364 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1365 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1366 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1367 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1368 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1369 a) 15mm nominal bore 1370 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1371 a) 15mm nominal bore 1372 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1373 a) 15mm nominal bore 1374 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1375 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1376 25mm nominal bore, weighing not less than 62 gms 1377 cutting holes up to 30x30 cm in walls including making good the same: 1378 with common burnt clay f.p.s. (non modular) bricks 1379 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1380 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1381 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1382 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1383 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1384 repair to plaster and plinth protection 1385 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1386 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1387 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1388 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1389 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1390 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1391 with cement mortar 1:4 (1cement: 4 coarse sand) 1392 12mm cement plaster of mix : 1393 1:6 (1 cement : 6 course sand) 1394 6mm cement plaster to ceiling of mix : 1395 1:3 ( 1 cement : 3 fine sand) 1396 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1397 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1398 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1399 old work (one or more coats) 1400 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1401 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1402 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1403 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1404 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1405 repairs to door / windows 1406 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1407 of area 3 sq. metres and below 1408 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1409 of area 3 sq. metres and below 1410 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1411 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1412 renewal of old putty of glass panes (length) 1413 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1414 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1415 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1416 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1417 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1418 300 mm weighing not less than 200gms. 1419 250 mm weighing not less than 150gms. 1420 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1421 100x58x1.90 mm 1422 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1423 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1424 300 x 10mm 1425 150 x 10mm 1426 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 1427 providing and fixing to existing door frames. 1428 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1429 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1430 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1431 with isi marked stainless steel butt hinges of required size 1432 kiln seasoned and chemically treated hollock wood 1433 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1434 with 12 mm mild steel u beading 1435 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1436 125 mm 1437 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1438 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1439 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1440 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1441 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1442 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1443 4.0 mm thick glass panes 1444 applying priming coat : 1445 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1446 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1447 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1448 two or more coats on new work 1449 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1450 one or more coats on old work 1451 flooring 1452 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1453 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1454 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1455 25 mm thick 1456 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1457 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 1458 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 1459 miscellaneous 1460 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1461 cement mortar 1:6 (1 cement : 6 coarse sand) 1462 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1463 cement mortar 1:4 (1 cement :4 coarse sand 1464 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1465 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1466 electrical work of type-ii (g) 1467 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1468 group b 1469 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1470 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1471 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1472 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1473 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1474 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1475 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1476 group b 1477 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1478 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1479 2 x 1.5 sq. mm 1480 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1481 25 mm 1482 32 mm 1483 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1484 100 mm x 100 mm x 60 mm deep 1485 150 mm x 75 mm x 60 mm deep 1486 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1487 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1488 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1489 s/f light plug point modular type accessories :- 1490 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1491 s/f power plug point modular type accessories :- 1492 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1493 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1494 supplying and fixing brass batten/ angle holder including connection etc. as required. 1495 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1496 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1497 6 way, double door 1498 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1499 4 way (4 + 12), double door 1500 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1501 single pole 1502 single pole and neutral 1503 triple pole 1504 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1505 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1506 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1507 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1508 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1509 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1510 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1511 supply of 15w surface mounted round led with all accessories as per standard item.. 1512 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1513 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1514 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1515 sewerage system 1516 excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 1517 all kinds of soil 1518 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1519 pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 1520 providing and laying non-pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1521 150 mm dia. r.c.c. pipe 1522 450 mm dia. r.c.c. pipe 1523 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40 mm nominal size) 1524 150 mm diameter s.w.pipe (l*.35*.10) 1525 450 mm diameter s.w.pipe (l*.6*.15 ) 1526 constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with rcc top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 1527 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 1528 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 1529 extra for depth for manholes: 1530 size 90 x 80 cm 1531 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1532 constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with fps bricksclass designation 75in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 1533 0.91m deep with sfrc cover and frame (heavy duty hd-20 grade designation) 560mm internal diameter conforming to i.s:12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) 1534 with common burnt clay f.p.s.(non module) brick of class designation 7.5 1535 extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . 1536 with common burnt clay f.p.s.(non module) brick of class designation 7.5 1537 providing and fixing square mouths. w. gully trapclass sp-1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 1538 180 x 150 mm. size p type 1539 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1540 providing m.s. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1541 with 20x20 mm square bar 1542 cleaning of chocked sewer line by diesel running vehicle mountinghydraulic operated high pressure suction cum jetting sewer cleaningmachine fitted with pump having 4000 litres suction capacity and6000 litres water jetting tank capacity including skilled operator,supervising engineer etc. for cleaning and partial desilting of manholesand dechocking of sewer lines. dechocking and flushing of sewerline from one manhole to another by high pressure jetting system of2200 psi for sewer line from 150mm dia upto 300mm 1543 cleaning and desilting of gully trap chamber, including removal ofrubbish mixed with earth etc. and disposal of same, all as per thedirection of engineer-in-charge. 1544 septic tank 1545 size of tank = 5.00 x 2.00 x 1.24 mtr 1546 excavation work by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 1547 all kinds soil 1548 take 50 % qty of items 1.a 1549 ordinary rock 1550 take 50 % qty of items 1.a 1551 excavation work by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 1552 earth work in excavation 1.50-3.00 mtr 1553 all kinds soil 1554 take 50 % qty of items 2.a 1555 ordinary rock 1556 take 50 % qty of items 2.a 1557 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 1558 20 % of excavation of items (1.a.1+2.a.1) 1559 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1560 1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40 mm nominal size). 1561 providing and laying in position machine batched and machine mixed design mix m-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer-in-charge.“(note :- cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1562 upto plinth level 1563 centering and shuttering including strutting, propping etc. and removal of form for: 1564 foundations, footings, bases of columns, etc. for mass concrete. 1565 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 1566 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1567 rcc bend beam 1568 suspended floors, roofs, landings, balconies and access platform. 1569 edges of slabs and breaks in floors and walls. 1570 under 20 cm wide 1571 providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of engineer-in-charge. 1572 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 1573 thermo-mechanically treated bars. 1574 up to plinth 1575 52 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. this includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 1576 for maintaining slope 1577 6 mm cement plaster on rough side of single or half brick wall of mix: 1578 1:3 (1 cement: 3 fine sand) 1579 providing and fixing in position pre-cast r.c.c. manhole cover and frame of required shape and approved quality 1580 hd-20 1581 circular shape 560 mm internal diameter 1582 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910 on 12mm dia steel bar conforming to is : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1583 providing and fixing soil, waste and vent pipes 1584 100 mm dia. 1585 centrifugally cast (spun) iron socketed pipe as per is: 3989. 1586 providing and fixing terminal guard : 1587 100 mm 1588 sand cast iron s&s as per is - 3989 1589 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and s.w. drain pipe 100 mm diameter, 1.8m long complete as per standard design.with f.p.s. bricks 1590 estimate of externalelectrical works 1591 subhead - i - main boards 1592 meter boards 1593 supply, installation, testing and commissioning of m.v. cubical type totally enclosed dust, dump and vermin proof meter bords complete with bus bars, mv danger notice plate, on surface isi marked electronic kwh meter, indication lamps, cts, interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingmcbs mccbs and kwh meters complete as required. 1594 meter boards - type-iii (6 nos) & warden residence ( 2 nos) & type-ii(1nos) 1595 incomer 1596 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 1597 metering & indication 1598 1 set of r,y,b phase indicating lamps 1599 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 1600 1 sets of breaker on-off-trip, spring charged indication lamps as required. 1601 bus-bar 1602 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 1603 out going: 1604 4 nos. 40a tpn mcb of 10ka 1605 2 nos. 40a dp mcb of 10ka. 1606 supplying,receiving, fixing, testing & commissioning ofabove described panel 1607 meter boards - principle residence & guest house. 1608 1 no.40amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 1609 panel -mp hall 1610 incomer 1611 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 1612 metering & indication 1613 1 set of r,y,b phase indicating lamps 1614 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 1615 1 sets of breaker on-off-trip, spring charged indication lamps as required. 1616 bus-bar 1617 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 1618 out going: 1619 4 nos. 40a tpn mcb of 10ka 1620 3 no. 40a dp mcb of 10ka. 1621 supplying,receiving, fixing, testing & commissioning ofabove described panel 1622 subhead - ii - earthing 1623 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 1624 earthing with cu. earth plate 600mm x 600mm x 3mm thick includingaccesssories, and providingmasonary enclosurewith cover plate (ci heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required. 1625 supplying and laying 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode, including connection with g.i. nut, bolt, spring, washer excavation and refilling etc. as required. 1626 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 1627 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required.
  • View Tender
  • Document
  • Bid Support
5 Civil Work
image image
State Government
TRN :49054583 |  15 May, 2025
Tender Value : 6.18 Lacs
 Athani - Karnataka
Tender for tender for supply of materials and machinery for construction of shg sanjeevini shed at nandeshwar village of athani taluka- providing and laying rcc pipe np3,unit cost as per the specification.bbb,tractor - 40 hp.bbb,pvc door shutter (nandi or equivalent) supply and fixing of door shuttersmade of rigid pvc extruded hollow section (nandi or equivalent) o f 20mm x 200mm etc,atn46 providing and placing on terrace, polyethylene water storage tanks with manhole lidand suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flowpipes, including cost of all materials, labour, transport charges, hom of equipments and testingcomplete as per specifications.(for 1000 litre capacity) as per is 12701 1996. specification no.kbs13.22,atn45 providing and installing at site of work p.v.c. pipes including cost of pipes andspecials and labour, including lowering into trenches, laying true to line, level and perfect linking at jointsleak proof including jointing of approved type with all labour and lift charges, handling charges includingencasing the pipe alround to a depth not less than 15 cms with gravel or selected earth available fromthe excavation etc. complete. for pvc pipes of 4 kg./cm2 110 mm,atn44 providing and installing at site of work p.v.c. pipes including cost of pipes andspecials and labour, including lowering into trenches, laying true to line, level and perfect linking at jointsleak proof including jointing of approved type with all labour and lift charges, handling charges includingencasing the pipe alround to a depth not less than 15 cms with gravel or selected earth available fromthe excavation etc. complete. for pvc pipes of 4 kg./cm2 a)63 mm .,atn41 providing and fixing white vitreous china clay, flat back wash basin size 550x400mmwith a pair of 15mm c.p brass pillar taps with c.i / m.s brackets, 32 mm c.p. brass waste of standardpattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required,including cost of materials, labour complete as per specifications.,atn40 providing and fixing white vitreous china clay, water closet orissa pattern of size 580 x440mm with integral type footrests, 100mm s or p trap, 10 litre low level, p.v.c flushing cistern ( all areapproved make ) with fittings, c.i / m.s brackets, 32mm diameter flush pipe fittings and clamps, overflowarrangements with special and 25mm mosquito proof coupling of approved design, painting of fittingsand brackets, cutting and making good the wall and floor wherever including cost of material,atn32 providing and fixing in position anodized aluminium windows and ventilators as perapproved drawings with sliding shutters using three track window frame of size 92x31.75mm bottomsection 1.3mm thick, weight etc complete,providing and fixing rcc door frame,atn29 providing matti / nandi wood frames of doors, windows, clerestory windows, ventilatorsand other frames, wrought, framed or assembled including making plaster groves ( excluding cost ofcement concrete and side clamps ), but including cost of materials, labour, hom of machineriescomplete as per specifications.,atn36 providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on10mm thick cement plaster,atn34 providing and fixing special make glazed vitrified tiles (granomite finish) of approvedmake, quality and colour of size 600x600x10mm thick fixed on existing flooring with a special adhesivefor flooring and skirting and jointed with neat cement slurry mixed with pigment to match the shade oftiles., including providing spacers at required interval and removing stains etc.,cost ofmaterials,mortar,labour etc., complete as per specifications.,atn39 providing and finishing external walls in two coats with waterproof cement paint ofapproved brand and shade to give an even shade after throughly brooming the surface to remove all dirtand loose powdered material, free from mortar drops and other foreign matter cost of materials, labour,complete as per specifications.,atn38 providing and applying painting in two coats with plastic emulsion paint ofapproved brand on wall surface to give an even approved shade after throughly brushing the surface,free from mortar drops and other foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour, complete as per specifications.,atn31 providing and fixing m.s.grill work for windows and ventilators weighing 21kg/sqm usingm.s. flats, or m.s. square rods, or combination of m.s. flats and square rods as per approved design,drawing including cutting steel sections and welding the same to required pattern with a coat of red leadprimer, cost of materials, fixtures, labour and hom of machinery complete as per specifications,atn23 providing and removing centering, shuttering, strutting, propping etc., and removal ofform work for foundations, footings,,atn22 burnt bricks class 35 (non modular),atn15 mixer (concrete small used in culvert),atn11 binding wire,atn10 tmt bars fe 500,atn3 broken stone aggregate 40 mm size,atn9 hom of vibrator 0.71 days,atn7 mixer (concrete) - 1 cum capacity,atn8 plasticizer / super plasticizer,atn6 portland cement,atn2 coarse sand (zone iii),atn5 broken stone aggregate 12 mm to 10 mm size,atn4 broken stone aggregate 20 mm size
  • View Tender
  • Document
  • Bid Support
6 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
7 Recreational Services
image image
State Government
TRN :49054761 |  21 May, 2025
Tender Value : 0
 Howrah - West Bengal
Tender for work related to the outdoor programme on bangla moder gorbo, to be held at darjeeling-1 alluminium hanger for 3 days 1.01 construction of a tarpaulin shed hanger for stage, audience area, stalls, exhibition, green room and office room having 16000 sq.ft. area (200 ft. x 80 ft. x 28 ft. height at the center and 16 ft. height at the circumference) to be constructed with durable alluminium including transportation 2 iron stage for 3 days: 2.01 wooden platform on iron structure base for performing stage with iron legs (32x24x4h) 2.02 wooden platform on iron structure base for led with iron legs (20x4x5h) 2.03 platform for outbox speaker (4x4x3) with proper masking 2.04 covered area for light, sound & other console 3 meter room for 3 days : 3.01 20x10x10 tarpaulin shedded bamboo structure 4 green room for 3 days ; 4.01 40x10x10 green room with octanum wall with platform and all necessary eminities with 2 components (male and female) 5 office room for 3 days : 5.01 20x10x10 octanum wall and platform 6 backdrop: 6.01 thematic set 3d backdrop of main dias (440 sqft.) 7 flower decoration for 3 days : 7.01 floral decoration in front of the stage with original and artificial flowers 8 musking for 3 days : 8.01 cloth musking with bamboo structure 4500 sqft 9 truss for 3 days : 9.01 18+18+18+36 goalpost for stage, 16+16+32 goalpost for light 9.02 12+ 8 t truss for stage light (2 nos) 9.03 16+ 8 t truss for special illumination on outside venue (4 nos) 10 sound for 3 days : 10.01 stage monitor 10.02 outbox speaker top and low 10.03 amplifier 10.04 microphone on stand 10.05 cordless microphone 10.06 audio mixer (48 channel) 10.07 dvd player with usb and vga port support 10.08 power board 10.09 other accessories like main cable, mixer port, inbox cable, transmeter, spliter, feedback cutter, microphone code for sound system 10.1 voltage stabilizer(10kw) 10.11 sound engineer 10.12 1 pair sound system for outside led 11 light (stage & venue) stage light for 3 days: 11.01 led par for stage 11.02 led face par 11.03 surphy 16 r with digital gobo 11.04 light engineer 11.05 haze machine 12 venue light for 3 days : 12.01 400 watt led metal for venue and outside 12.02 rice chain for outside venue 13 stand fan with safty net for 3 days : 13.01 for green room, vip room 13.02 for stage, audience, stalls 13.03 power board 14 power for 3 days 14.01 65 kva for stage sound + 1 back up (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 14.02 125 kva for stage light (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 14.03 wbsedcl charges (as actual) 15 branding city branding: (with transportation, labour & fixing) 15.01 wooden hoarding with flex printing (10x5) 15.02 3d cut-out 4x12 16 branding venue branding: (with labour & fixing) 16.01 standee (iron structure with flex printing) 4x8 16.02 wooden hoarding (with flex printing ) 8x6 16.03 walkway pillar (with flex printing) 10x4x4 16.04 venue gate (iron/wooden structure with flex branding) 16.05 programme schedule (wooden structure with flex printing) 10x5 16.06 facia and flex musking for all stalls, green room, office room and exhibition area 16.07 3d stage skirting with flex 32x24x24x4 16.08 led raiser flex musking 24x4x4 (152 sqft) 16.09 flag on rope 17 printing & others: 17.01 batch 6x4 with printed ribbon 17.02 car sticker 7x5 17.03 directional signage flex with wooden framing: vos (2x1.5) 17.04 signage for sitting area (4 colour print) 18 camera, led, plasma & connectivity for 3 days : 18.01 still camera hd with camera man 18.02 video camera hd with camera man and attendent 18.03 still documentation dvd with editing 18.04 video documentation dvd with editing 18.05 p3 led for projection 18.06 laptop with connectivity 18.07 dop & team for 1 days for entire light scheming 18.08 cabling & technician 19 misc. for 3 days : 19.01 notation stand 19.02 decorative podium 19.03 mirror for green room 19.04 walky-talky 19.05 fire extinguisher with proper filling 19.06 bio toilet with light and sufficient water supply and including transportation & cleaner 20 manpower including transportation, lodging & fooding: 20.01 supervisor for 5 days 20.02 incharge for 5 days 20.03 event boys for 3 days 20.04 security for 5days (2 shift x 4 heads x 5 days) 21 artist & musician hospitality, transportation, accomodation & food for 3 days: 21.01 transportation / movement of artiste, guests by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the guest/artists from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of artistes maybe at last time. tatkal booking may also be required on emergency. total nos. of artiste/ guests may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the artistes also may change at last minute of the programme including local transportation. accommodation/ nightstay & food of all artiste/performer/guests who will move from kolkata in ac suite/ similar category room 21.02 transportation / movement of musician by ac car/ train (3ac) facilities from kolkata to the venue & return ac vehicles to receive the musician from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of musician maybe at last time tatkal booking may also be required on emergency. total nos. of musician may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the musician also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of musician who will move from kolkata in ac category room 21.03 transportation / movement of officials by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the officials from their house to the railway station of kolkata & same from station of the destination station. tatkal booking may also be required on emergency. total nos. of officials may be changed on urgent basis. all tickets has to be confirmed on urgent basis and name of the officials also may change at last minute of the programme including local transportation. accommodation/ nightstay & food of all officials who will move from kolkata in ac suite/ similar category room 21.04 attache for artist (for 6 artists 3 days) 22 stall for 3 days : 22.01 10x10 octanum stall, platform, carpet on floor, 2 exhibition chair, 2 exhibition table, sufficient light, 2 nos 15 amp power board 22.02 100x10 exhibition area with octanum, platform, carpet, top back side musking, front facia, leg, faciaside with thematic & special illumination 22.03 thematic stall with asthetic design (size: 8x8), look & feel, installation, thematic illumination 23 digital outreach as a promotional campaign in social media 23.01 charges for concept designing, strategic management (audience segmentation; detailed demographic targetting; identification of potential audience/ viewers etc.) and supervision/ monitoring of whole campaign by competent personnel. 23.02 customization/creation of suitable number of contents (visuals/ reels/ stories etc.) as per instruction of department for different social media with required camera, drone, light & sound. direction with proper skilled set-up/ man-power, composing & editing of files/content with proper background sound & colour correction for the event/ programme having three days duration in north bengal districts (department reserves the right to fix the number of content as per actual requirement and nature of event. selected bidder will be binding to execute the work on the basis of lowest discovered rate) 23.03 boosting (technical and strategic initiative for improvement of viewership) of posts/ contents in social media viz. facebook, instagram, x, youtube and other social media prior to the event/ during the event/ after completion of the event as per instruction of i & c.a. deptt. (authenticated transaction receipt is to be furnished being charge of boosting; payment will be made on actual basis). boosting work is to be done maintaining close liaison with nodal officer of the event. department may issue instruction to continue the boosting work at any stage in respect of the event after tracking performance of boosting. 24 govt. taxes 24.01 including all govt. taxes
  • View Tender
  • Document
  • Bid Support
8 Recreational Services
image image
State Government
TRN :49054776 |  21 May, 2025
Tender Value : 0
 Howrah - West Bengal
Tender for the work related to the outdoor programme on bangla moder gorbo, to be held at kalimpong-1 alluminium hanger for 3 days 1.01 construction of a tarpaulin shed hanger for stage, audience area, stalls, exhibition, green room and office room having 16000 sq.ft. area (200 ft. x 80 ft. x 28 ft. height at the center and 16 ft. height at the circumference) to be constructed with durable alluminium including transportation 2 iron stage for 3 days: 2.01 wooden platform on iron structure base for performing stage with iron legs (32x24x4h) 2.02 wooden platform on iron structure base for led with iron legs (20x4x5h) 2.03 platform for outbox speaker (4x4x3) with proper masking 2.04 covered area for light, sound & other console 3 meter room for 3 days : 3.01 20x10x10 tarpaulin shedded bamboo structure 4 green room for 3 days ; 4.01 40x10x10 green room with octanum wall with platform and all necessary eminities with 2 components (male and female) 5 office room for 3 days : 5.01 20x10x10 octanum wall and platform 6 backdrop: 6.01 thematic set 3d backdrop of main dias (440 sqft.) 7 flower decoration for 3 days : 7.01 floral decoration in front of the stage with original and artificial flowers 8 musking for 3 days : 8.01 cloth musking with bamboo structure 4500 sqft 9 truss for 3 days : 9.01 18+18+18+36 goalpost for stage, 16+16+32 goalpost for light 9.02 12+ 8 t truss for stage light (2 nos) 9.03 16+ 8 t truss for special illumination on outside venue (4 nos) 10 sound for 3 days : 10.01 stage monitor 10.02 outbox speaker top and low 10.03 amplifier 10.04 microphone on stand 10.05 cordless microphone 10.06 audio mixer (48 channel) 10.07 dvd player with usb and vga port support 10.08 power board 10.09 other accessories like main cable, mixer port, inbox cable, transmeter, spliter, feedback cutter, microphone code for sound system 10.1 voltage stabilizer(10kw) 10.11 sound engineer 10.12 1 pair sound system for outside led 11 light (stage & venue) stage light for 3 days: 11.01 led par for stage 11.02 led face par 11.03 surphy 16 r with digital gobo 11.04 light engineer 11.05 haze machine 12 venue light for 3 days : 12.01 400 watt led metal for venue and outside 12.02 rice chain for outside venue 13 stand fan with safty net for 3 days : 13.01 for green room, vip room 13.02 for stage, audience, stalls 13.03 power board 14 power for 3 days 14.01 65 kva for stage sound + 1 back up (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 14.02 125 kva for stage light (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 14.03 wbsedcl charges (as actual) 15 branding city branding: (with transportation, labour & fixing) 15.01 wooden hoarding with flex printing (10x5) 15.02 3d cut-out 4x12 16 branding venue branding: (with labour & fixing) 16.01 standee (iron structure with flex printing) 4x8 16.02 wooden hoarding (with flex printing ) 8x6 16.03 walkway pillar (with flex printing) 10x4x4 16.04 venue gate (iron/wooden structure with flex branding) 16.05 programme schedule (wooden structure with flex printing) 10x5 16.06 facia and flex musking for all stalls, green room, office room and exhibition area 16.07 3d stage skirting with flex 32x24x24x4 16.08 led raiser flex musking 24x4x4 (152 sqft) 16.09 flag on rope 17 printing & others: 17.01 batch 6x4 with printed ribbon 17.02 car sticker 7x5 17.03 directional signage flex with wooden framing: vos (2x1.5) 17.04 signage for sitting area (4 colour print) 18 camera, led, plasma & connectivity for 3 days : 18.01 still camera hd with camera man 18.02 video camera hd with camera man and attendent 18.03 still documentation dvd with editing 18.04 video documentation dvd with editing 18.05 p3 led for projection 18.06 laptop with connectivity 18.07 dop & team for 1 days for entire light scheming 18.08 cabling & technician 19 misc. for 3 days : 19.01 notation stand 19.02 decorative podium 19.03 mirror for green room 19.04 walky-talky 19.05 fire extinguisher with proper filling 19.06 bio toilet with light and sufficient water supply and including transportation & cleaner 20 manpower including transportation, lodging & fooding: 20.01 supervisor for 5 days 20.02 incharge for 5 days 20.03 event boys for 3 days 20.04 security for 5days (2 shift x 4 heads x 5 days) 21 artist & musician hospitality, transportation, accomodation & food for 3 days: 21.01 transportation / movement of artiste, guests by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the guest/artists from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of artistes maybe at last time. tatkal booking may also be required on emergency. total nos. of artiste/ guests may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the artistes also may change at last minute of the programme including local transportation. accommodation/ nightstay & food of all artiste/performer/guests who will move from kolkata in ac suite/ similar category room 21.02 transportation / movement of musician by ac car/ train (3ac) facilities from kolkata to the venue & return ac vehicles to receive the musician from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of musician maybe at last time tatkal booking may also be required on emergency. total nos. of musician may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the musician also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of musician who will move from kolkata in ac category room 21.03 transportation / movement of officials by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the officials from their house to the railway station of kolkata & same from station of the destination station. tatkal booking may also be required on emergency. total nos. of officials may be changed on urgent basis. all tickets has to be confirmed on urgent basis and name of the officials also may change at last minute of the programme including local transportation. accommodation/ nightstay & food of all officials who will move from kolkata in ac suite/ similar category room 21.04 attache for artist (for 6 artists 3 days) 22 stall for 3 days : 22.01 10x10 octanum stall, platform, carpet on floor, 2 exhibition chair, 2 exhibition table, sufficient light, 2 nos 15 amp power board 22.02 100x10 exhibition area with octanum, platform, carpet, top back side musking, front facia, leg, faciaside with thematic & special illumination 22.03 thematic stall with asthetic design (size: 8x8), look & feel, installation, thematic illumination 23 digital outreach as a promotional campaign in social media 23.01 charges for concept designing, strategic management (audience segmentation; detailed demographic targetting; identification of potential audience/ viewers etc.) and supervision/ monitoring of whole campaign by competent personnel. 23.02 customization/creation of suitable number of contents (visuals/ reels/ stories etc.) as per instruction of department for different social media with required camera, drone, light & sound. direction with proper skilled set-up/ man-power, composing & editing of files/content with proper background sound & colour correction for the event/ programme having three days duration in north bengal districts (department reserves the right to fix the number of content as per actual requirement and nature of event. selected bidder will be binding to execute the work on the basis of lowest discovered rate) 23.03 boosting (technical and strategic initiative for improvement of viewership) of posts/ contents in social media viz. facebook, instagram, x, youtube and other social media prior to the event/ during the event/ after completion of the event as per instruction of i & c.a. deptt. (authenticated transaction receipt is to be furnished being charge of boosting; payment will be made on actual basis). boosting work is to be done maintaining close liaison with nodal officer of the event. department may issue instruction to continue the boosting work at any stage in respect of the event after tracking performance of boosting. 24 govt. taxes 24.01 including all govt. taxes
  • View Tender
  • Document
  • Bid Support
9 Recreational Services
image image
State Government
TRN :49054833 |  21 May, 2025
Tender Value : 0
 Howrah - West Bengal
Tender for the work related to stage decoration, light, sound, etc. for the programme of shraddhanjali at different districts of west bengal- 1 furniture for 2 days 2 hiring charges for supplying, fitting, fixing of executive 3 seater sofa for vip lounge 3 hiring charges for supplying, fitting, fixing of fibre chair with cover : for back stage fiber chair with cover 4 hiring charges for supplying, fitting, fixing of fibre chair: for out side audience 5 hiring charges for supplying, fitting, fixing of 5x3 table with cover & frill: for back stage 6 hiring charges for supplying, fitting, fixing of5x3 table with cover & frill: for console & feed 7 hiring charges for supplying, fitting, fixing of 5x3 table with cover & frill 8 carpeting for 2 days 9 carpeting for main stage &lounge area 10 backdrop for 2 days 11 themetic backdrop on main stage 40x16 12 flower decoration and portrait for 2 days 13 flower decoration at the front of the dias with mixing of original and artificial flowers 14 portrait (3’ x 2’) of artiste with proper flower decoration 15 flower pot in front of portrait with sufficient flower and petals 16 musking & truss for 2 days 17 console & raiser masking 18 truss 2x2 : 14x28 goal post 19 truss 2x2 : 12x8 t-truss 20 truss 2x2 : 16x8 t-truss for outside illumination 21 sound for 2 days 22 hire charges for supplying & fitting & fixing of 1 low + 1 top 23 hire charges for supplying & fitting & fixing of stage monitor 24 hire charges for supplying & fitting & fixing of outbox speaker 15 25 hire charges for supplying & fitting & fixing of amplifier 26 hire charges for supplying & fitting & fixing of microphone on stand 27 hire charges for supplying & fitting & fixing of cordless microphone 28 hire charges for supplying & fitting & fixing of digital mixer with operator 64 channel 29 dvd player 30 laptop 31 hire charges for supplying & fitting & fixing of digital recorder (new endo) 32 hire charges for supplying & fitting & fixing of voltage stabilizer(10kw) 33 hire charges for supplying & fitting & fixing of compressor & sound limitors 34 hire charges for supplying & fitting & fixing of audio db box for tv channel 35 hire charges for supplying & fitting & fixing of podium mic 36 power board 37 sound engineer for 2 days 38 other accessories 39 light (auditorium & venue) for 2 days 40 hire charges for supplying & fitting & fixing of400 watt metal for stage 41 hire charges for supplying & fitting & fixing ofled par for stage & inside auditorium 42 hire charges for supplying & fitting & fixing of surphy for stage & inside auditorium 43 hire charges for supplying & fitting & fixing of led face par for stage 44 hire charges for supplying & fitting & fixing of haze machine for stage 45 light engineer for 2 days 46 hire charges for supplying & fitting & fixing of led par for venue concerned 47 hire charges for supplying & fitting & fixing of surphy for venue concerned 48 hire charges for supplying & fitting & fixing of metal 400 watt for outside & pathway for venue light 49 hire charges for supplying & fitting & fixing of led mirchi on road for venue light 50 panel board for more than 100 kv load for venue light 51 earthing with 2 dia gi pipes as per pwd gs for venue light 52 genarator for 2 days 53 62.5 kva generator for stage light (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 54 power pack / cabelling 55 branding for 2 days 56 flex 8x6 (wooden frame) 57 flex 4x8 (wooden frame) 58 3-d customizedgate with decoration:decoration of the gates will be made by flex painting 59 led raiser musking with flex on wooden structure 60 look & feel around the venue 61 camera, feed, led, plasma & connectivity for 2 days 62 still camera hd with camera man 63 video camera hd with camera man 64 online editing setup with a team of editors 65 documentation album with laciehard disk 66 still documentation dvd with editing 67 video documentation dvd with editing 68 p3 led for themetic led backdrop 16x8 (128 sq ft.) 69 p3 led for outside led 12x8, 2 nos of size 96 sq ft each 70 sound for led 71 xvga cable 72 plasma 42for on stage including cablling & swicher 73 plasma 42for back stage including cablling & swicher 74 plasma 42for feed room including cablling & swicher 75 plasma 42for console including cablling & swicher 76 preperation of 3d graphical av for main stage 77 laptop with connectivity 78 cablling & techician 79 misc. for 2 days 80 hire charges & supplying of notation stand 81 hire charges & supplying of walky-talky 82 hire charges & supplying of decorative podium 83 hire charges & supplying of lamp stand with lighting kit 84 hire charges & supplying of tent card for lounge area 85 signages for sitting & lounge area (4 colour print) 86 manpower for 2 days 87 hiring charges for supervisor (4 nos each day) 88 hiring charges for event co.ordinator for front stage & back stage(8 nos each day) 89 hiring charges for lady hostess to escort guests (4 nos each day) 90 hiring charges for thali girl (2 nos each day) 91 hiring charges for girls as promoters for stage management (4 nos each day) 92 hiring charges for ushers (female) for audience management (2 nos each day) 93 hiring charges for boys as promoters for stage management (4 nos each day) 94 f & b for 2 days 95 tea 100 cups for vvip@ rs.20 each (100 cup each day) 96 tea with biscuit 400 cups for artists, musicians ,officials etc.@rs.12 each (200 cup each day) 97 standard food packet for 100 heads @rs.300 each packet for guest, vip and dignitaries (100 packet each day) 98 tiffin packets for musicians, staffs & officials for 200 heads @rs.160 each (200 packet each day) 99 miscellanous 100 tribute standee through erected truss (900 sq. ft) with proper illumination 101 reahearsal for 3 days at sangeet academy/ nandan iv 102 sound system for 3 days at sangeet academy/ nandan for rehearsal 103 tea 150 cup per day for 3 days @ rs. 12/- per cup 104 50 food packets per day for 3 days @rs. 250/- per food packet 105 conveyance, accommodation and hospitality for musicians 106 hiring charges of 3 nos. a.c. innova for 3 days (in case of transporation by railway, actual fair will be reimbusered on production of journey tickets) 107 local transport (ac innova 3 nos) for north bengal districts for 3 days, if required 108 accommodation (5 suitable rooms) charge for 2 daysfor 9 musicians and 1 sound co-ordinator 109 fooding charge for 2 daysfor 9 musicians and 1 sound co-ordinator 110 fooding charge for 2 daysfor 9 musicians and 1 sound co-ordinator on transit days 111 conveyance, accommodation and hospitality for artistes and officials 112 hiring charges of 6 nos. a.c. innova for 3 days (in case of transporation by railway, actual fair will be reimbusered on production of journey tickets) 113 local transport (ac innova 6 nos) for north bengal districts for 3 days, if required 114 accommodation (18 suitable rooms) charge for 2 daysfor 14 artistes and officials 115 fooding charge for 2 daysfor 14 heads 116 fooding charge for 2 daysfor 14 heads on transit days 117 genarator for 2 days 118 62.5 kva generator for outside led & illumination (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 119 25 kva generator for sound (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 120 digital outreach as a promotional campaign in social media 121 charges for concept designing, strategic management (audience segmentation; detailed demographic targetting; identification of potential audience/ viewers etc.) and supervision/ monitoringof whole campaign by competent personnel. 122 customization/creation of suitable number of contents (visuals/ reels/ stories etc.) as per instruction of department for different social media with required camera, drone, light & sound. direction with proper skilled set-up/ man-power, composing & editing of files/content with proper background sound & colour correction for the event/ programme having two days in districts (department reserves the right to fix the number of content as per actual requirement and nature of event. selected bidder will be binding to execute the work on the basis of lowest discovered rate). 123 boosting (technical and strategic initiative for improvement of viewership) of posts/ contents in social media viz. facebook, instagram, x, youtube and other social media prior to the event/ during the event/ after completion of the event as per instruction of i & c.a. deptt. (authenticated transaction receipt is to be furnished being charge of boosting; payment will be made on actual basis). boosting work is to be done maintaining close liaison with nodal officer of the event. department may issue instruction to continue the boosting work at any stage in respect of the event after tracking performance of boosting. 124 govt. taxes 125 all applicable govt. taxes (18%)
  • View Tender
  • Document
  • Bid Support
10 Recreational Services
image image
State Government
TRN :49054903 |  21 May, 2025
Tender Value : 0
 Howrah - West Bengal
Tender for the work related to the outdoor programme on bangla moder gorbo, to be held at coochbehar- 1 alluminium hanger for 3 days 2 construction of a tarpaulin shed hanger for stage, audience area, stalls, exhibition, green room and office room having 16000 sq.ft. area (200 ft. x 80 ft. x 28 ft. height at the center and 16 ft. height at the circumference) to be constructed with durable alluminium including transportation 3 iron stage for 3 days: 4 wooden platform on iron structure base for performing stage with iron legs (32x24x4h) 5 wooden platform on iron structure base for led with iron legs (20x4x5h) 6 platform for outbox speaker (4x4x3) with proper masking 7 covered area for light, sound & other console 8 meter room for 3 days : 9 20x10x10tarpaulin shedded bamboo structure 10 green room for 3 days ; 11 40x10x10 green room with octanum wall with platform andall necessary eminities with 2 components (male and female) 12 officeroom for 3 days : 13 20x10x10 octanum wall and platform 14 backdrop: 15 thematicset 3d backdrop of main dias (440 sqft.) 16 flower decoration for 3 days : 17 floral decoration in front of the stage with original and artificial flowers 18 musking for 3 days : 19 cloth musking with bamboo structure 4500 sqft 20 truss for 3 days : 21 18+18+18+36 goalpost for stage, 16+16+32 goalpost for light 22 12+ 8 t truss for stage light (2 nos) 23 16+ 8 t truss for special illumination on outside venue (4 nos) 24 sound for 3 days : 25 stage monitor 26 outbox speaker top and low 27 amplifier 28 microphone on stand 29 cordless microphone 30 audio mixer (48 channel) 31 dvd player with usb and vga port support 32 power board 33 other accessories like main cable, mixer port, inbox cable, transmeter, spliter, feedback cutter, microphone codefor sound system 34 voltage stabilizer(10kw) 35 sound engineer 36 1 pair sound system for outside led 37 light (stage & venue) stage light for 3 days: 38 led par for stage 39 led face par 40 surphy 16 r with digital gobo 41 light engineer 42 haze machine 43 venue light for 3 days : 44 400 watt led metal for venue and outside 45 rice chain for outside venue 46 stand fan with safty net for 3 days : 47 for green room, vip room 48 for stage, audience, stalls 49 power board 50 power for 3 days 51 65 kva for stage sound + 1 back up(fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 52 125 kva for stage light(fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 53 wbsedcl charges (as actual) 54 branding city branding: (with transportation, labour & fixing) 55 wooden hoarding with flex printing (10x5) 56 3d cut-out 4x12 57 branding venue branding: (with labour & fixing) 58 standee (iron structure with flex printing) 4x8 59 wooden hoarding (with flex printing ) 8x6 60 walkway pillar (with flex printing) 10x4x4 61 venue gate (iron/wooden structure with flex branding) 62 programme schedule (wooden structure with flex printing) 10x5 63 facia and flex muskingfor all stalls, green room, office room and exhibition area 64 3d stage skirting with flex 32x24x24x4 65 led raiser flex musking 24x4x4 (152 sqft) 66 flag on rope 67 printing & others: 68 batch 6x4 with printed ribbon 69 car sticker 7x5 70 directional signage flex with wooden framing: vos (2x1.5) 71 signage for sitting area (4 colour print) 72 camera, led, plasma & connectivity for 3 days : 73 still camera hd with camera man 74 video camera hd with camera man and attendent 75 still documentation dvd with editing 76 video documentationdvd with editing 77 p3 led for projection 78 laptop with connectivity 79 dop & team for 1 days for entire light scheming 80 cabling & technician 81 misc. for 3 days : 82 notation stand 83 decorative podium 84 mirror for green room 85 walky-talky 86 fire extinguisher with proper filling 87 bio toilet with light and sufficient water supply and including transportation & cleaner 88 manpower including transportation, lodging & fooding: 89 supervisor for 5 days 90 incharge for 5 days 91 event boys for 3 days 92 security for 5days (2 shift x 4 heads x 5 days) 93 artist & musician hospitality, transportation, accomodation & food for 3 days: 94 transportation / movement of artiste, guests by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the guest/artists from their house to the railway stationof kolkata & same from station of the destination station to the programme confirmation of artistes maybe at last time. tatkal booking may also be required on emergency. total nos. of artiste/ guests may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the artistes also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of all artiste/performer/guests who will move from kolkata in ac suite/ similar category room 95 transportation / movement of musician by ac car/ train (3ac) facilities from kolkata to the venue & return ac vehicles to receive the musician from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of musician maybe at last time tatkal booking may also be required on emergency. total nos. of musician may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the musician also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of musician who will move from kolkata in accategory room 96 transportation / movement of officials by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the officials from their house to the railway stationof kolkata & same from station of the destination station. tatkal booking may also be required on emergency. total nos. of officials may be changed on urgent basis. all tickets has to be confirmed on urgent basis and name of the officials also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of all officials who will move from kolkata in ac suite/ similar category room 97 attache for artist (for 6 artists 3 days) 98 stall for 3 days : 99 10x10 octanum stall, platform, carpet on floor, 2 exhibition chair, 2 exhibition table, sufficient light, 2 nos 15 amp power board 100 100x10 exhibition area with octanum, platform, carpet, top back side musking, front facia, leg, faciaside with thematic & special illumination 101 thematic stall with asthetic design (size: 8x8), look & feel, installation, thematic illumination 102 digital outreach as a promotional campaign in social media 103 charges for concept designing, strategic management (audience segmentation; detailed demographic targetting; identification of potential audience/ viewers etc.) and supervision/ monitoringof whole campaign by competent personnel. 104 customization/creation of suitable number of contents (visuals/ reels/ stories etc.) as per instruction of department for different social media with required camera, drone, light & sound. direction with proper skilled set-up/ man-power, composing & editing of files/content with proper background sound & colour correction for the event/ programme having three days duration in north bengal districts (department reserves the right to fix the number of content as per actual requirement and nature of event. selected bidder will be binding to execute the work on the basis of lowest discovered rate) 105 boosting (technical and strategic initiative for improvement of viewership) of posts/ contents in social media viz. facebook, instagram, x, youtube and other social media prior to the event/ during the event/ after completion of the event as per instruction of i & c.a. deptt. (authenticated transaction receipt is to be furnished being charge of boosting; payment will be made on actual basis). boosting work is to be done maintaining close liaison with nodal officer of the event. department may issue instruction to continue the boosting work at any stage in respect of the event after tracking performance of boosting. 106 govt. taxes 107 including all govt. taxes a
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • 4
  • 5
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : rig machine
  • Drill Press Tenders ,
  • Well Logging Machine Tenders ,
  • Diamond Core Drill Tenders ,
  • Drilling Derricks Tenders ,
  • Rock Drilling Equipment Tenders ,
  • Drilling Hoses Tenders ,
  • Drilling Item Tenders ,
  • Rotary Rig Machine Tenders ,
  • Radial Drilling Machine Scrap Tenders ,
  • Earth Auger Tenders

Get rig machine Tender Alert...

794046

Related Searched Keywords : rig machine

  • Acoustic Panels Tenders From Maharashtra
  • Ceiling Tenders From Delhi
  • Tiles Flooring Tenders From West-Bengal
  • Dismantling Work Tenders From -Tamil-Nadu
  • Canal Work Tenders From Andhra-Pradesh
  • Compound Wall Tenders From Gujarat
  • Buildings Repair Tenders From Karnataka
  • Railway Under Bridge Tenders From Uttar-Pradesh
  • Lift Irrigation Work Tenders From Rajasthan
  • Building Work Tenders From Madhya-Pradesh

Read More


Tender Document

630227

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Civil Engineering Tenders
  • Rcc Pile Foundation Tenders
  • Excavation Tenders
  • Water Proofing Treatment Work Tenders
  • Borewell Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App