Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Security Wall
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of security-wall Tenders

List of latest security-wall Tenders in Indian Tenders. Click on any security-wall Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for security-wall Tenders.

Advance Search
  • All-Tenders (40)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
3 Security Services
image image
Central Government/Public Sector
TRN :49054675 |  05 Jun, 2025
Tender Value : 52.42 Lacs
 Dehradun - Uttarakhand
Tender for special repair to drainage system and fencing of security wall at fafa tel bhawan under age b/r-ii of ge dehradun
  • View Tender
  • Document
  • Bid Support
4 Recreational Services
image image
State Government
TRN :49054761 |  21 May, 2025
Tender Value : 0
 Howrah - West Bengal
Tender for work related to the outdoor programme on bangla moder gorbo, to be held at darjeeling-1 alluminium hanger for 3 days 1.01 construction of a tarpaulin shed hanger for stage, audience area, stalls, exhibition, green room and office room having 16000 sq.ft. area (200 ft. x 80 ft. x 28 ft. height at the center and 16 ft. height at the circumference) to be constructed with durable alluminium including transportation 2 iron stage for 3 days: 2.01 wooden platform on iron structure base for performing stage with iron legs (32x24x4h) 2.02 wooden platform on iron structure base for led with iron legs (20x4x5h) 2.03 platform for outbox speaker (4x4x3) with proper masking 2.04 covered area for light, sound & other console 3 meter room for 3 days : 3.01 20x10x10 tarpaulin shedded bamboo structure 4 green room for 3 days ; 4.01 40x10x10 green room with octanum wall with platform and all necessary eminities with 2 components (male and female) 5 office room for 3 days : 5.01 20x10x10 octanum wall and platform 6 backdrop: 6.01 thematic set 3d backdrop of main dias (440 sqft.) 7 flower decoration for 3 days : 7.01 floral decoration in front of the stage with original and artificial flowers 8 musking for 3 days : 8.01 cloth musking with bamboo structure 4500 sqft 9 truss for 3 days : 9.01 18+18+18+36 goalpost for stage, 16+16+32 goalpost for light 9.02 12+ 8 t truss for stage light (2 nos) 9.03 16+ 8 t truss for special illumination on outside venue (4 nos) 10 sound for 3 days : 10.01 stage monitor 10.02 outbox speaker top and low 10.03 amplifier 10.04 microphone on stand 10.05 cordless microphone 10.06 audio mixer (48 channel) 10.07 dvd player with usb and vga port support 10.08 power board 10.09 other accessories like main cable, mixer port, inbox cable, transmeter, spliter, feedback cutter, microphone code for sound system 10.1 voltage stabilizer(10kw) 10.11 sound engineer 10.12 1 pair sound system for outside led 11 light (stage & venue) stage light for 3 days: 11.01 led par for stage 11.02 led face par 11.03 surphy 16 r with digital gobo 11.04 light engineer 11.05 haze machine 12 venue light for 3 days : 12.01 400 watt led metal for venue and outside 12.02 rice chain for outside venue 13 stand fan with safty net for 3 days : 13.01 for green room, vip room 13.02 for stage, audience, stalls 13.03 power board 14 power for 3 days 14.01 65 kva for stage sound + 1 back up (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 14.02 125 kva for stage light (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 14.03 wbsedcl charges (as actual) 15 branding city branding: (with transportation, labour & fixing) 15.01 wooden hoarding with flex printing (10x5) 15.02 3d cut-out 4x12 16 branding venue branding: (with labour & fixing) 16.01 standee (iron structure with flex printing) 4x8 16.02 wooden hoarding (with flex printing ) 8x6 16.03 walkway pillar (with flex printing) 10x4x4 16.04 venue gate (iron/wooden structure with flex branding) 16.05 programme schedule (wooden structure with flex printing) 10x5 16.06 facia and flex musking for all stalls, green room, office room and exhibition area 16.07 3d stage skirting with flex 32x24x24x4 16.08 led raiser flex musking 24x4x4 (152 sqft) 16.09 flag on rope 17 printing & others: 17.01 batch 6x4 with printed ribbon 17.02 car sticker 7x5 17.03 directional signage flex with wooden framing: vos (2x1.5) 17.04 signage for sitting area (4 colour print) 18 camera, led, plasma & connectivity for 3 days : 18.01 still camera hd with camera man 18.02 video camera hd with camera man and attendent 18.03 still documentation dvd with editing 18.04 video documentation dvd with editing 18.05 p3 led for projection 18.06 laptop with connectivity 18.07 dop & team for 1 days for entire light scheming 18.08 cabling & technician 19 misc. for 3 days : 19.01 notation stand 19.02 decorative podium 19.03 mirror for green room 19.04 walky-talky 19.05 fire extinguisher with proper filling 19.06 bio toilet with light and sufficient water supply and including transportation & cleaner 20 manpower including transportation, lodging & fooding: 20.01 supervisor for 5 days 20.02 incharge for 5 days 20.03 event boys for 3 days 20.04 security for 5days (2 shift x 4 heads x 5 days) 21 artist & musician hospitality, transportation, accomodation & food for 3 days: 21.01 transportation / movement of artiste, guests by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the guest/artists from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of artistes maybe at last time. tatkal booking may also be required on emergency. total nos. of artiste/ guests may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the artistes also may change at last minute of the programme including local transportation. accommodation/ nightstay & food of all artiste/performer/guests who will move from kolkata in ac suite/ similar category room 21.02 transportation / movement of musician by ac car/ train (3ac) facilities from kolkata to the venue & return ac vehicles to receive the musician from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of musician maybe at last time tatkal booking may also be required on emergency. total nos. of musician may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the musician also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of musician who will move from kolkata in ac category room 21.03 transportation / movement of officials by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the officials from their house to the railway station of kolkata & same from station of the destination station. tatkal booking may also be required on emergency. total nos. of officials may be changed on urgent basis. all tickets has to be confirmed on urgent basis and name of the officials also may change at last minute of the programme including local transportation. accommodation/ nightstay & food of all officials who will move from kolkata in ac suite/ similar category room 21.04 attache for artist (for 6 artists 3 days) 22 stall for 3 days : 22.01 10x10 octanum stall, platform, carpet on floor, 2 exhibition chair, 2 exhibition table, sufficient light, 2 nos 15 amp power board 22.02 100x10 exhibition area with octanum, platform, carpet, top back side musking, front facia, leg, faciaside with thematic & special illumination 22.03 thematic stall with asthetic design (size: 8x8), look & feel, installation, thematic illumination 23 digital outreach as a promotional campaign in social media 23.01 charges for concept designing, strategic management (audience segmentation; detailed demographic targetting; identification of potential audience/ viewers etc.) and supervision/ monitoring of whole campaign by competent personnel. 23.02 customization/creation of suitable number of contents (visuals/ reels/ stories etc.) as per instruction of department for different social media with required camera, drone, light & sound. direction with proper skilled set-up/ man-power, composing & editing of files/content with proper background sound & colour correction for the event/ programme having three days duration in north bengal districts (department reserves the right to fix the number of content as per actual requirement and nature of event. selected bidder will be binding to execute the work on the basis of lowest discovered rate) 23.03 boosting (technical and strategic initiative for improvement of viewership) of posts/ contents in social media viz. facebook, instagram, x, youtube and other social media prior to the event/ during the event/ after completion of the event as per instruction of i & c.a. deptt. (authenticated transaction receipt is to be furnished being charge of boosting; payment will be made on actual basis). boosting work is to be done maintaining close liaison with nodal officer of the event. department may issue instruction to continue the boosting work at any stage in respect of the event after tracking performance of boosting. 24 govt. taxes 24.01 including all govt. taxes
  • View Tender
  • Document
  • Bid Support
5 Recreational Services
image image
State Government
TRN :49054776 |  21 May, 2025
Tender Value : 0
 Howrah - West Bengal
Tender for the work related to the outdoor programme on bangla moder gorbo, to be held at kalimpong-1 alluminium hanger for 3 days 1.01 construction of a tarpaulin shed hanger for stage, audience area, stalls, exhibition, green room and office room having 16000 sq.ft. area (200 ft. x 80 ft. x 28 ft. height at the center and 16 ft. height at the circumference) to be constructed with durable alluminium including transportation 2 iron stage for 3 days: 2.01 wooden platform on iron structure base for performing stage with iron legs (32x24x4h) 2.02 wooden platform on iron structure base for led with iron legs (20x4x5h) 2.03 platform for outbox speaker (4x4x3) with proper masking 2.04 covered area for light, sound & other console 3 meter room for 3 days : 3.01 20x10x10 tarpaulin shedded bamboo structure 4 green room for 3 days ; 4.01 40x10x10 green room with octanum wall with platform and all necessary eminities with 2 components (male and female) 5 office room for 3 days : 5.01 20x10x10 octanum wall and platform 6 backdrop: 6.01 thematic set 3d backdrop of main dias (440 sqft.) 7 flower decoration for 3 days : 7.01 floral decoration in front of the stage with original and artificial flowers 8 musking for 3 days : 8.01 cloth musking with bamboo structure 4500 sqft 9 truss for 3 days : 9.01 18+18+18+36 goalpost for stage, 16+16+32 goalpost for light 9.02 12+ 8 t truss for stage light (2 nos) 9.03 16+ 8 t truss for special illumination on outside venue (4 nos) 10 sound for 3 days : 10.01 stage monitor 10.02 outbox speaker top and low 10.03 amplifier 10.04 microphone on stand 10.05 cordless microphone 10.06 audio mixer (48 channel) 10.07 dvd player with usb and vga port support 10.08 power board 10.09 other accessories like main cable, mixer port, inbox cable, transmeter, spliter, feedback cutter, microphone code for sound system 10.1 voltage stabilizer(10kw) 10.11 sound engineer 10.12 1 pair sound system for outside led 11 light (stage & venue) stage light for 3 days: 11.01 led par for stage 11.02 led face par 11.03 surphy 16 r with digital gobo 11.04 light engineer 11.05 haze machine 12 venue light for 3 days : 12.01 400 watt led metal for venue and outside 12.02 rice chain for outside venue 13 stand fan with safty net for 3 days : 13.01 for green room, vip room 13.02 for stage, audience, stalls 13.03 power board 14 power for 3 days 14.01 65 kva for stage sound + 1 back up (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 14.02 125 kva for stage light (fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 14.03 wbsedcl charges (as actual) 15 branding city branding: (with transportation, labour & fixing) 15.01 wooden hoarding with flex printing (10x5) 15.02 3d cut-out 4x12 16 branding venue branding: (with labour & fixing) 16.01 standee (iron structure with flex printing) 4x8 16.02 wooden hoarding (with flex printing ) 8x6 16.03 walkway pillar (with flex printing) 10x4x4 16.04 venue gate (iron/wooden structure with flex branding) 16.05 programme schedule (wooden structure with flex printing) 10x5 16.06 facia and flex musking for all stalls, green room, office room and exhibition area 16.07 3d stage skirting with flex 32x24x24x4 16.08 led raiser flex musking 24x4x4 (152 sqft) 16.09 flag on rope 17 printing & others: 17.01 batch 6x4 with printed ribbon 17.02 car sticker 7x5 17.03 directional signage flex with wooden framing: vos (2x1.5) 17.04 signage for sitting area (4 colour print) 18 camera, led, plasma & connectivity for 3 days : 18.01 still camera hd with camera man 18.02 video camera hd with camera man and attendent 18.03 still documentation dvd with editing 18.04 video documentation dvd with editing 18.05 p3 led for projection 18.06 laptop with connectivity 18.07 dop & team for 1 days for entire light scheming 18.08 cabling & technician 19 misc. for 3 days : 19.01 notation stand 19.02 decorative podium 19.03 mirror for green room 19.04 walky-talky 19.05 fire extinguisher with proper filling 19.06 bio toilet with light and sufficient water supply and including transportation & cleaner 20 manpower including transportation, lodging & fooding: 20.01 supervisor for 5 days 20.02 incharge for 5 days 20.03 event boys for 3 days 20.04 security for 5days (2 shift x 4 heads x 5 days) 21 artist & musician hospitality, transportation, accomodation & food for 3 days: 21.01 transportation / movement of artiste, guests by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the guest/artists from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of artistes maybe at last time. tatkal booking may also be required on emergency. total nos. of artiste/ guests may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the artistes also may change at last minute of the programme including local transportation. accommodation/ nightstay & food of all artiste/performer/guests who will move from kolkata in ac suite/ similar category room 21.02 transportation / movement of musician by ac car/ train (3ac) facilities from kolkata to the venue & return ac vehicles to receive the musician from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of musician maybe at last time tatkal booking may also be required on emergency. total nos. of musician may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the musician also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of musician who will move from kolkata in ac category room 21.03 transportation / movement of officials by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the officials from their house to the railway station of kolkata & same from station of the destination station. tatkal booking may also be required on emergency. total nos. of officials may be changed on urgent basis. all tickets has to be confirmed on urgent basis and name of the officials also may change at last minute of the programme including local transportation. accommodation/ nightstay & food of all officials who will move from kolkata in ac suite/ similar category room 21.04 attache for artist (for 6 artists 3 days) 22 stall for 3 days : 22.01 10x10 octanum stall, platform, carpet on floor, 2 exhibition chair, 2 exhibition table, sufficient light, 2 nos 15 amp power board 22.02 100x10 exhibition area with octanum, platform, carpet, top back side musking, front facia, leg, faciaside with thematic & special illumination 22.03 thematic stall with asthetic design (size: 8x8), look & feel, installation, thematic illumination 23 digital outreach as a promotional campaign in social media 23.01 charges for concept designing, strategic management (audience segmentation; detailed demographic targetting; identification of potential audience/ viewers etc.) and supervision/ monitoring of whole campaign by competent personnel. 23.02 customization/creation of suitable number of contents (visuals/ reels/ stories etc.) as per instruction of department for different social media with required camera, drone, light & sound. direction with proper skilled set-up/ man-power, composing & editing of files/content with proper background sound & colour correction for the event/ programme having three days duration in north bengal districts (department reserves the right to fix the number of content as per actual requirement and nature of event. selected bidder will be binding to execute the work on the basis of lowest discovered rate) 23.03 boosting (technical and strategic initiative for improvement of viewership) of posts/ contents in social media viz. facebook, instagram, x, youtube and other social media prior to the event/ during the event/ after completion of the event as per instruction of i & c.a. deptt. (authenticated transaction receipt is to be furnished being charge of boosting; payment will be made on actual basis). boosting work is to be done maintaining close liaison with nodal officer of the event. department may issue instruction to continue the boosting work at any stage in respect of the event after tracking performance of boosting. 24 govt. taxes 24.01 including all govt. taxes
  • View Tender
  • Document
  • Bid Support
6 Recreational Services
image image
State Government
TRN :49054903 |  21 May, 2025
Tender Value : 0
 Howrah - West Bengal
Tender for the work related to the outdoor programme on bangla moder gorbo, to be held at coochbehar- 1 alluminium hanger for 3 days 2 construction of a tarpaulin shed hanger for stage, audience area, stalls, exhibition, green room and office room having 16000 sq.ft. area (200 ft. x 80 ft. x 28 ft. height at the center and 16 ft. height at the circumference) to be constructed with durable alluminium including transportation 3 iron stage for 3 days: 4 wooden platform on iron structure base for performing stage with iron legs (32x24x4h) 5 wooden platform on iron structure base for led with iron legs (20x4x5h) 6 platform for outbox speaker (4x4x3) with proper masking 7 covered area for light, sound & other console 8 meter room for 3 days : 9 20x10x10tarpaulin shedded bamboo structure 10 green room for 3 days ; 11 40x10x10 green room with octanum wall with platform andall necessary eminities with 2 components (male and female) 12 officeroom for 3 days : 13 20x10x10 octanum wall and platform 14 backdrop: 15 thematicset 3d backdrop of main dias (440 sqft.) 16 flower decoration for 3 days : 17 floral decoration in front of the stage with original and artificial flowers 18 musking for 3 days : 19 cloth musking with bamboo structure 4500 sqft 20 truss for 3 days : 21 18+18+18+36 goalpost for stage, 16+16+32 goalpost for light 22 12+ 8 t truss for stage light (2 nos) 23 16+ 8 t truss for special illumination on outside venue (4 nos) 24 sound for 3 days : 25 stage monitor 26 outbox speaker top and low 27 amplifier 28 microphone on stand 29 cordless microphone 30 audio mixer (48 channel) 31 dvd player with usb and vga port support 32 power board 33 other accessories like main cable, mixer port, inbox cable, transmeter, spliter, feedback cutter, microphone codefor sound system 34 voltage stabilizer(10kw) 35 sound engineer 36 1 pair sound system for outside led 37 light (stage & venue) stage light for 3 days: 38 led par for stage 39 led face par 40 surphy 16 r with digital gobo 41 light engineer 42 haze machine 43 venue light for 3 days : 44 400 watt led metal for venue and outside 45 rice chain for outside venue 46 stand fan with safty net for 3 days : 47 for green room, vip room 48 for stage, audience, stalls 49 power board 50 power for 3 days 51 65 kva for stage sound + 1 back up(fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 52 125 kva for stage light(fuel cost will be provided separately on the basis of actual consumption including one skilled manpower charge as per labour departments order) 53 wbsedcl charges (as actual) 54 branding city branding: (with transportation, labour & fixing) 55 wooden hoarding with flex printing (10x5) 56 3d cut-out 4x12 57 branding venue branding: (with labour & fixing) 58 standee (iron structure with flex printing) 4x8 59 wooden hoarding (with flex printing ) 8x6 60 walkway pillar (with flex printing) 10x4x4 61 venue gate (iron/wooden structure with flex branding) 62 programme schedule (wooden structure with flex printing) 10x5 63 facia and flex muskingfor all stalls, green room, office room and exhibition area 64 3d stage skirting with flex 32x24x24x4 65 led raiser flex musking 24x4x4 (152 sqft) 66 flag on rope 67 printing & others: 68 batch 6x4 with printed ribbon 69 car sticker 7x5 70 directional signage flex with wooden framing: vos (2x1.5) 71 signage for sitting area (4 colour print) 72 camera, led, plasma & connectivity for 3 days : 73 still camera hd with camera man 74 video camera hd with camera man and attendent 75 still documentation dvd with editing 76 video documentationdvd with editing 77 p3 led for projection 78 laptop with connectivity 79 dop & team for 1 days for entire light scheming 80 cabling & technician 81 misc. for 3 days : 82 notation stand 83 decorative podium 84 mirror for green room 85 walky-talky 86 fire extinguisher with proper filling 87 bio toilet with light and sufficient water supply and including transportation & cleaner 88 manpower including transportation, lodging & fooding: 89 supervisor for 5 days 90 incharge for 5 days 91 event boys for 3 days 92 security for 5days (2 shift x 4 heads x 5 days) 93 artist & musician hospitality, transportation, accomodation & food for 3 days: 94 transportation / movement of artiste, guests by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the guest/artists from their house to the railway stationof kolkata & same from station of the destination station to the programme confirmation of artistes maybe at last time. tatkal booking may also be required on emergency. total nos. of artiste/ guests may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the artistes also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of all artiste/performer/guests who will move from kolkata in ac suite/ similar category room 95 transportation / movement of musician by ac car/ train (3ac) facilities from kolkata to the venue & return ac vehicles to receive the musician from their house to the railway station of kolkata & same from station of the destination station to the programme confirmation of musician maybe at last time tatkal booking may also be required on emergency. total nos. of musician may be change on urgent basis. all tickets has to be confirmed on urgent basis and name of the musician also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of musician who will move from kolkata in accategory room 96 transportation / movement of officials by ac car/ train (2ac) facilities from kolkata to the venue & return luxury ac vehicles to receive the officials from their house to the railway stationof kolkata & same from station of the destination station. tatkal booking may also be required on emergency. total nos. of officials may be changed on urgent basis. all tickets has to be confirmed on urgent basis and name of the officials also may change at last minute of the programme including local transportation.accommodation/ nightstay & food of all officials who will move from kolkata in ac suite/ similar category room 97 attache for artist (for 6 artists 3 days) 98 stall for 3 days : 99 10x10 octanum stall, platform, carpet on floor, 2 exhibition chair, 2 exhibition table, sufficient light, 2 nos 15 amp power board 100 100x10 exhibition area with octanum, platform, carpet, top back side musking, front facia, leg, faciaside with thematic & special illumination 101 thematic stall with asthetic design (size: 8x8), look & feel, installation, thematic illumination 102 digital outreach as a promotional campaign in social media 103 charges for concept designing, strategic management (audience segmentation; detailed demographic targetting; identification of potential audience/ viewers etc.) and supervision/ monitoringof whole campaign by competent personnel. 104 customization/creation of suitable number of contents (visuals/ reels/ stories etc.) as per instruction of department for different social media with required camera, drone, light & sound. direction with proper skilled set-up/ man-power, composing & editing of files/content with proper background sound & colour correction for the event/ programme having three days duration in north bengal districts (department reserves the right to fix the number of content as per actual requirement and nature of event. selected bidder will be binding to execute the work on the basis of lowest discovered rate) 105 boosting (technical and strategic initiative for improvement of viewership) of posts/ contents in social media viz. facebook, instagram, x, youtube and other social media prior to the event/ during the event/ after completion of the event as per instruction of i & c.a. deptt. (authenticated transaction receipt is to be furnished being charge of boosting; payment will be made on actual basis). boosting work is to be done maintaining close liaison with nodal officer of the event. department may issue instruction to continue the boosting work at any stage in respect of the event after tracking performance of boosting. 106 govt. taxes 107 including all govt. taxes a
  • View Tender
  • Document
  • Bid Support
7 Security Services
image image
Central Government/Public Sector
TRN :49055104 |  28 May, 2025
Tender Value : 35.00 Lacs
 Udhampur - Jammu And Kashmir
Tender for repair of drain footpath security wall gate fencing repair to path compound wall at samnabanj rc peak and battle node under ge army dhar road
  • View Tender
  • Document
  • Bid Support
8 Security Services
image image
Central Government/Public Sector
TRN :49055340 |  31 May, 2025
Tender Value : 49.00 Lacs
 Pune - Maharashtra
Tender for tender for welcome maint to offrs md accn under age br-i of ge (south) pune; 1 m&l for preparation of old decorative surfaces of ceiling including cornices (plastered or un-plastered) by brooming down and scrapping wherever necessary and applying one coat of white wash complete all as specified and directed 2 m&l for preparation of old decorative surfaces of wall including, cornices (plastered or unplastered)of any description, sand papered and dusted and applying one coat of oil bound distemper of any tint complete all as specified and directed. 3 m&l for preparation of old decorative surfaces of wall including, cornices (plastered or unplastered)of any description, sand papered , and dusted including complete removal of existing surface of walland applying two coats of oil bound distemper over and including a coat of 2mm thick wall care putty complete all as specified and directed 4 m&l for preparation of old painted wooden surfaces exc. 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed 5 m&l for preparation of old painted steel surfaces exc. 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed 6 m & l for preparation of surface of any description (plastered and old decorated) over 10 cm width or girth including removing of existing treatment completely and applying two coats of weather proof exterior paint complete all as specified and directed 7 m&l for preparation of old painted surfaces of walls by brooming down or steel wire brushing , scraping down soot, moulds, moss and efflorescent salt etc surface of any description (plastered and old decorated) over 10 cm width or girth and applying one coatof weather proof exterior paint complete all as specified and directed 8 m & l for preparation of surface of any description (plastered and old decorated) over 10 cm width or girth and applying one coat of luster paint complete all as specified and directed 9 m & l for french polishing on surfaces of any description, exceeding 10 cm width or girth over and including a coat of a coat of wood filler including cleaning and preparation of old wooden surfaces complete all as specified and directed 10 m & l for applying two coatsof oil bound distemper on walls over and including a coat ofpriming with chalk whitening including preparation of new plaster surfaces complete all as specified and directed 11 m&l for applying three coats of white washon ceiling and including preparation of new plaster surface complete all as specified and directed 12 m&l for applying two coats of cement base paintover and including a coat of alkali resistant primer on walls including preparation of new plaster surfaces complete all as specified and directed 13 m & l for preparation of brooming down or steel wire brushing, scraping down soot, moulds, moss and efflorescent salt etc and applying one coat of cement base paint over and including a coat ofalkali resistant primer on walls including preparation of oldsurfaces complete all as specified and directed 14 taking down cement plaster from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water complete all as specified and directed. 15 m&l for 15 mm thick plaster in cm 1:3 on concrete surfaces finished even and smooth using sagol finish on ceiling complete all as specified and directed 16 demolition of brickwork masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. 17 m&l for old sizefly ash bricks, straight or curved on plan exc. 6 m mean radiusbuilt in cm 1:6 complete all as specified and directed 18 m&l for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cm 1:4 complete all as specified and directed 19 m&l for rendering 20 mm thick plaster in two layers on stone masonry surfaces or on other than fair faces of brick / pcc block masonry of walls (first layer 10 mm thick in cement mortar 1:6 and second layer 10mm thick in cm 1:6) and finishing the surface even and smooth without using extra cement complete all as specified and directed. 20 m&l for rendering 20 mm thick plaster in two layers on stone masonry surfaces or on other than fair faces of brick / pcc block masonry of walls (first layer 10 mm thick in cement mortar 1:6 and second layer 10mm thick in cm 1:4 mixed with wpc as per manufacturer’s instructions) and finishing the surface even and smooth without using extra cement complete all as specified and directed.note :- wpc shall be measured and paid separately as supply only under respective item of boq. 21 m&l for rendering 15 mm thick on fair faces of brick work / concrete surfaces in cement mortar 1:4mixed with water proofing compound as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified and directed.note :- wpc shall be measured and paid separately as supply only under respective item of boq. 22 m&l for rendering 15 mm thick on fair faces of brick work in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed 23 m&l for pcc 1:3:6 type c-1, (using 20mm graded stone aggregate) of75mm thick, laid in alternate bays as in path and plinth protection including finishing the surfaces even andsmooth using extra cement, complete all as specified and directed 24 s&f in repairs pvc connection 60cm long 15mm dia with 2 nos. pvc nuts repairs complete all as specified and directed. 25 demolition of cement concrete in ground floor and pavings n. exc. 15 cm thickness (below or above gl), complete all as specified and directed. 26 demolition cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. 27 m&l glazed coloured digital printed ceramic tiles of size 600x300x7-8mm thick in vertical surfaces etc set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles with and including 15mm thick backing coat in cm 1:4 including triangular filleting in cm 1:4 on top edges including dismantling of old unserviceable tiles including backing coat of any description and removal of debries & dismantled materials complete all as specified and directed 28 m & lfor water proofing treatment to sunken slab, walls,etc. shall be carried out as specified below and as directed by engineer-in-charge:-(a) dismantling & remove the existing lean concrete completely and clean the sunken portion of toilet / baths / wcs / kitchen thoroughly remove laitance, dirt, dust etc.(b) form angle fillet of size 40 mm x 40 mm along the junction of wall and floor by using polymer modified mortar (“ dr fixit” pidicrete urp” or equivalent).(c) sanitary pipes entering through walls and floor shall be sealed with “dr fixit bathseal tape” and the gaps to be grouted with non-shrink cementitous grout “dr fixit bathseal grout” or equivalent. nahani traps etc to be fitted securely and the gaps around it to be grouted in the same manner.(d) apply one coat of a bitumen-modified polymer coating “dr fixit bathseal plus” or equivalent on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet and applying second coat of the same coating on the angle fillets and allow it to dry completely. contd...... 29 (e) in the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. extend the coating upto150mm above the ffi. above ffi, another cementitious waterproofing waterproof coating “dr fixit pidifin 2 k” or equivalent to be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hoours and allow to dry completely.(f) after 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed m 15 type b0 mixed with integral wpc (liquid) laid to stope 1:60 towards outer face of wall. provide 40 mm od upvc pipe at the lowest point with 300 mm projection beyond the outer face of the wall. then fill up the sunken portion with lean concrete 1:5:10 type e2.(g) after completing plumbing work in the toilet/wc/bath/kitchen, floor, tiling work (floor and dado) to be carried out by using suitable tile adhesives and ready to make tile grouts of approved makes such as dr fixit, fosroc sika, mc buchemie, roff, etc. note: lean concrete 1:5:10 type e-2 shall be measured and paid separately under respective item of boq. 30 m&l for pcc 1:5:10 type e-2 using 40 mm graded brick aggregate as in filling sunken portion, complete all as specified and directed. 31 m&l for 25 mm thick pcc 1:2:4 type b-1 (using 20mm graded stone aggregate) as in leveling course or pcc padding, finished the surfaces fair & even, complete all as specified and directed. 32 m&l for cleaning and removing all scale and dirt, etc, from tanks n. exc. 500 ltrcapacity and from mouths of circulating pipes etc including writing of date of cleaning with synthetic enamel paint complete all as specified and directed. 33 m&l for cleaning and removing all scale and dirt, etc, from tanks exc. 500 ltrs but n. exc. 1000 ltrcapacity and from mouths of circulating pipes etc including writing of date of cleaning with synthetic enamel paint complete all as specified and directed. 34 m&l for cleaning and removing all scale and dirt, etc, from tanks exc. 1000 ltrs but n. exc. 2000 ltrcapacity and from mouths of circulating pipes etc including writing of date of cleaning with synthetic enamel paint complete all as specified and directed. 35 m&l for granite (of any type) work (table rubbed and polished) 18-20mm thick as in steps, jambs, pillars, window- cills,cookingplatforms, as counters of any radiuos and like setting in neat cement slurry including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 20mm thick screed / backing coat in cement mortar (1:4)including dismantling of old unserviceable slab / tiles including screed bed of any description and removal of debries & dismantled materials complete all as specified and directed 36 rounding (half) of edges of granite stone slabs , as in steps, cooking plateform slab and other similar situations complete all as specified and directed. 37 s&f in repair cascade type (coloured) floor mounted single piecewater closet withpp soft close slim seat cover , hinges, dual flush cistern fittings, fixing accessories and accessories set , size 365 x 675 x740 mm, strap -220 mm pipe etcconnected to pipe complete all as specified and directed by engr in charge confirming to cat no. esc-wht-851s220sppsm essco (jaquar)or of equivalent make as specified here-in-after complete all as specified and directed 38 s&f in repairs glass coner assembly cosisting of 5.5 mm thicksheet glassround(9 x 9 ) with satinless steel railing, complete all as specified and directed 39 s&f inrepairs satinless steel robe hook (khuti) with5hook, complete all as specified and directed 40 s&f in repairs sink cock with swinging casted spout with aerator(wall mounted model) conforming to cat no. orb-105347 essco (jaquar) or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 41 s&f cp towel ring round with round flange conforming to cat no acn-1121 bn of jaquar / 9218 of prayag or equivalent cat part from the makes as specified here in after, complete all as specified and directed. 42 s&f in repairs brass chromium plated shower rose 100 dia with 235 mm long arm with or without swivel joints, including fixing to steel pipe or union, complete all as specified and directed 43 s&f in repairs brasscp wall mixer3- in-1 system with provn for both hand shower and overhead shower complete with 115 mm long bend pipe connecting legs and wall flange (without hand & ovwer shower ) conforming to cat no.ste-107281 stellaessco (jaquar) or equivalent cat part from the makes as specified here in after, complete all as specified and directed. 44 s&f in repairs cp 15 mm fancy long body bib taps brasswith wall falnge & aeratorconforming to cat no. sqt- 512kn essco ( jaquar) or equivalent cat part from the makes as specified here in after, complete all as specified and directed. 45 s&f in repairs soap dish cat no. acn-1131n jaquar / ba-259 of prayag or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 46 s&f in repairs cp toilet paper holder conforming to cat no. acn-1151 n of jaquar / ba-38 of prayag or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 47 s&f in repairs cp towel rail 20mm dia and600mm long including brackets conforming to cat no. acn-111n of jaquar/ ba-20 of prayag or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 48 s&f in repairs health faucet cat no. ald-583kn of jaquar/ bea-85 of prayag or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 49 s&f in repairs angular type stop cock with flangeconforming to cat no.apr -101053 essco of (jaquar) or equivalent cat part from the makes as specified here in after, complete all as specified and directed. 50 s&f in repairs cp 2 way bib cock with wall flange conforming to cat no. ste-107041,essco ( jaquar) , cera orequivalent cat part of makes as specified here-in-after, complete all as specified and directed 51 s&f in repairs cp pillartaps swan longneckwith aerator15mm bore fancy type with wall flange conforming to cat no orb -105001n essco ( jaquar) or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 52 s&f in repairs stainless steel towel rack with lower hangers, 600mm long conforming to cat no. can-1181fhs of jaquar or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 53 taking up or down steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed for following size of pipe :-(a). 15mm bore. 54 (b). 20mm bore. 55 s&f of following dia gi pipe, medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etccomplete all as specified and directed.(a). 15mm bore 56 (b). 20mm bore. 57 re-fixing only following dia gi pipe, medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etccomplete all as specified and directed.(a). 15mm bore 58 (b). 20mm bore. 59 m&l for cutting chases, pinning in, concrete, block /brick or stone walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing and making good, cutting n. exc. 10 cm girth, complete all as specified and directed. 60 s&f pvc (swr) 110mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or fixed to wall including dismantling of old unserviceable breaking up drain pipes pvc or ac set in cm or solvent,complete all as specified and directed.note for item nos. 55 & 56:- rate quoted shall deemed to be inclusive of necessary scaffolding / security measures as the work is to be carried out for elevated height upto 12 mtr height building. 61 s&f pvc (swr) 75mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or fixed to wall including dismantling of old unserviceable breaking up drain pipes pvc or ac set in cm or solvent,complete all as specified and directed. 62 s&f pvc (swr) bends any radius 110 mm bore complete all as specified and directed. 63 s&f pvc (swr) bends any radius 75 mm bore complete all as specified and directed. 64 s&f pvc (swr) vent cowl 110mm bore, complete all as specified & directed. 65 s&f in repairs pvc (swr) branch piece, (double y) equal or unequal of 110 mm bore, complete all as specified and directed 66 s&f in repairs pvc (swr) branch piece, (double y) equal or unequal of 75mm bore, complete all as specified and directed 67 s & f 110mm pvc (swr) wc connector bent type complete all as specified and directed. 68 s&f pvc (swr), 75mm dia outlet floor trap, plain with grating including jointing with solvent cement, fixed to cement concrete type b1 1:2:4, complete all as specified and directed. 69 s&f pvc (swr), 75mm dia outlet multi floor trap, plain with grating including jointing with solvent cement, fixed to cement concrete type b1 1:2:4, complete all as specified and directed. 70 m&l for cutting, screwing & threading of existing 15mm bore steel tubing for alterations or additions (each cut measured) complete all as specified and directed 71 m&l for cutting, screwing & threading of existing 20mm bore steel tubing for alterations or additions (each cut measured) complete all as specified and directed 72 m&l for cutting, screwing & threading of existing 25/32mm bore steel tubing for alterations or additions (each cut measured) complete all as specified and directed 73 taking down chowkhat or frames n. exc. 1.5 sqm each with shutter without taking off shutter from the frame complete all as specified and directed. 74 taking down chowkhat or frames exc. 1.5 sqm but n. exc. 4 sqm each with shutter without taking off shutter from the frame complete all as specified and directed. 75 taking down shutters of any description exc. 1 sqm and not exc. 2 sqm each and remove from site, complete all as specified and directed. 76 s&f in repairs vitreous china, squatting pan, orissa pattern, size 580 x 440 mm white, with integral foot rest, including concrete bedding and pvc flushing cistern 10 ltr capacity including all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed. 77 s & f in repairs, vitreous china wash basin, white, flat back, size 550 x 400 mm with brackets, inc. cutting for & pinning in ends of brackets, including32 mm dia brass cpwastecouplingand32 mmdia low density polyethylene(ldpe) pressure rating 6 kg / cm² as waste pipe complete all as specified and directed 78 s&f in repairs vitreous china wash down water closet pan, pedestal white, including fixing bolts etc including pvc seat cover white with flat bottom including ms, cp or aluminium anodised hinge devices including pvc low level flushing cistern 10 ltr capacity with all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed. 79 s&f in repairs ewc seat cover of any pattern including cover and mild steel chromium plated hinging devices of any colour, complete all as specified and directed. 80 s&f in repairs, stainless steel plate rack of size 36 inch x 30 inch x 10inch, made out of 0.63mm thick stainless steel sheet (grade 304), s s screws and round pipe,fixed to wall with screws complete all as specified and as directed 81 s&f in repairs flexible waste pipe of 32 mm dia suitable for wash hand basins, sink etc of suitable length, complete all as specified and directed 82 s & f in repairs spindles of any size suitable for concealed mixer valves, stop valves, angle cock, fancy taps including knob heads complete all as directed by engineer-in-charge. 83 s & f in repairs kitchen or laboratory sinks made of stainless steel 1mm thick sheet with plugs, washers, and wastes coupling, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, bowl size 560x460mm including coupling etc complete all as directed by engineer-in-charge. 84 s&f in repair high density 40mm bore polyethylene pipes (hdpe) of pressure rating 6 kg/cm2 fixed to wall or in floors with necessary socket, elbow & bendetc complete fixedto wall or in floors etc complete all as specified and directed. 85 s&fin repair pvc low level flushing cistern 10 ltrs capacity with and including all internal fitting, pair of bracket, including inlet / outlet pvc pipe connections etc. complete all as specified and directed 86 m&l for joint free non-skid ceramic coloured tiles 7 to 8 mm thick area of each tiles exceeding 0.11 sqm but not exceeding 0.18 as in floors, set an jointed in neat cement slurry and pointed in white or coloured cement to match including laid over and including 20 mm thick screed bed in cm 1:6 including taking of old existing unserviceable tiles of any type including screed bed and removing of debries & dismantled materials etc. complete all as specified and as directed 87 m&l for coloured vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.16 sqm but not exceeding 0.36 sqm as in flooring, set and jointed in neat cement slurry & pointed in white or coloured cement to match laid over and including 20mm thick screed bed in cm 1:6 with including taking of old existing unserviceable tiles of any type including screed bed and removing of debries & dismantled materials etc. complete all as specified and as directed 88 s&f in repairs 20mm dia aluminium powder coated, fancy type curtain rod medium grade fixed in and including bracket, stops roller etc complete all as specified and directed 89 s&f stainless steelfency type caps / side bulbs etc. suitable for 20mm dia curtain rod pipe complete all as specified and directed. 90 s & f pressed steel frames for doors with one & more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm including ms hold fast - 6 nos. and ms cold rolled 100mm size butt hinges welding to existing ms frame including pcc bed block in 1:2:4 type b1 for hold fast and cement concrete 1:3:6 type c1 (12.5mm graded stone aggregate) for filling in ms hollow frame complete all as specified and directed. 91 s & f pressed steel frames for doors with one & more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm including ms hold fast - 3 nos. and ms cold rolled 100mm size butt hinges welding to existing ms frame including pcc bed block in 1:2:4 type b1 for hold fast and cement concrete 1:3:6 type c1 (12.5mm graded stone aggregate) for filling in ms hollow frame complete all as specified and directed. 92 s&f pvc door frame of size 50mm x 47 mm made out of 5mm plain colour pvc sheet reinforced with ms square tube, suppling & fixing in opening as per specification and drawing. 93 supply and fixing factory made solid pvc shutters,30 mm thick (style) consisting of frame made out of ms tube for top and bottom rails. ms frame shall be covered with heat moulded plain colour pvc c channel having a pvc sheet strips of 20mm width stuck inside with solvent cement for stiles and plain cover pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail; panneling of plain colour pvc sheet to be fitted in the ms frame welded / sealed to the stiles & rail with suitable pvc sheet beading, and joined together with solvent cement, supply and fixing in the frame at site as per specification and drawing. 94 s&f 300 mm long aluminium alloy, anodised , sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy fixed complete all as specified and directed. 95 s&f 200 mm long aluminium, anodised, barrel tower bolts of extruded section isi marked complete all as specified anddirected. 96 s&f 100mm size extruded aluminium anodised alloy handles, fabricated type, isi marked complete all as specified anddirected. 97 s&f pvc (swr) gully trap 125x110mm, setting and jointing with solvent cement, complete all as specified and directed. 98 s&f 100 mm long butt hinge, alum electroplated, heavy weight, cold rolled mild steel and fixed complete all as specified and directed. 99 s&f in repairs 600 x 450mm beveled edge lookingmirror of selected quality glass, mounted on 6 mm thick ac built board or commercial ply board and fixed to wooden plug with chromium plated brass screws and cup washer etc. complete all as specified and as directed 100 s&f aluminium powder coatedthree track sliding window with two or more shutters with & including 4mm thick tinted glass, one shutter of stainless steel wire cloth 0.36 mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing, handle, lock etc using pvc beadingetc using following sections of `jindal aluminum ltd or equivalent in ajit india pvt ltd or crystal bombay, as approved fixing to stone masonry walls with & including ist class teak wood plugs of size 20mmx20mm at an interval of 0.5m around the track including drilling holes etc complete all as specified and directed:(a) frame bottom20620(b) frame top& side 20681(c) shutters top & bottom 20844(d) shutter inter lock 20724(e) handle (side) for 20606 shutters 101 s&f ventiltors / louvers with partially guaged shutter using 5 mm thick x 10 cm wide frostedglass strips andby using of following aluminium powder coated sections conforming to catalogue of jindal or of equivalent make including with rubber beading etc, complete all as directed by engr-in-charge.(a) sp20048(b) glazing clips19352 102 s & f150 mm length floor door stopper of brassbody and tongue, hard drawn steel spring complete all as specified and directed. 103 s&f of 18/19 mm thick block board, grade i quality exterior grade type with decorative face veneer on both faces including lapping of edges fixed with screws to timber frame work as in cb partition and shelf and other works complete including dismantling of old unserviceable boards of any type complete all as specified and directed 104 s&f continuous (piano) hinges, mild steel, bright finish, width of flaps (when open) 30mm, complete all as specified and directed. 105 s&f in replacement 100 mm brass fancy type cupboard handle fixed with nuts, screws and washer of brass polished, complete all as specified and directed. 106 s&f in repairs magnet catches and striking plate, complete all as specified and directed 107 removing building materials etc to a distance exceeding 5 km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed. 108 m&l for gypsum ceiling board,pre-painted, perforated finish, 600x600x8 to 9mm thick in size of approved brand / make, laid over and including grid work of size 595 x 595mm, made out of 0.5mm thick g.i. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle, hung from ceiling by using 2 mm thick g.i. suspension wires spaced at 1200 mm on main runners including making niches for fans & light , complete all as specified and directed 109 all as per item no.103 but repair only to the existing false ceilings of any description complete all as directed by engr-in-charge 110 dismantling of wall / ceiling boards including snap grid of any thickness including cover fillets, complete all as specified and directed. 111 s&f 4 mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beadings in square n. exc 0.5 sqm in each pane, including hacking out old broken glass if any (any thickness, quality & size), complete all as specified and directed. 112 m&l for machine cut cudappah stone slab one side pre-polished, 30-40mm thick as in kitchen platform base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 15 mm thick screed bedding layer in cm 1:4 including dismantling of old unserviceable slab / tiles including screed bed of any description and removal of debries & dismantled materials complete all as specified and directed 113 s&f of 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sideincluding 5mm thick,1st class hw (tw) beading all around on edging andcomplete all as specified and directed by engr-in-charge 114 m&l for 35mm thick iind class hard wood glazed and skeleton shutters, openrebated and prepare to receive glass (with sash bars), guage etc divided into squares with plain, chamfered or rounded, mitered and rebated sash bars any number, size of members of shutters as specifie in clause 8.24(a) of ssr part-i 2009, complete all as specified and directed. 115 m&l for applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description exc. 10 cm width or girth, including preparation of surfaces, complete al as specified and directed. 116 m&l for applying two coats of synthetic enamel paint over acoat of red oxide primer on new steel surfaces exc. 10 cm width or girth, including preparation of surfaces, complete al as specified and directed. 117 m&l for 2nd class hard wood wrought plain fillets square, rectangular or triangular in section clean sawn secured with screws, sectional area exc. 13 sqcm but n. exc. 25 sqcm etc complete including dismantling of timber fillets from cabinet / cupboard frame, complete all as specified and directed 118 s & f in repairs gun metal, globe gate valves(class i), with iron wheel head,screwed both ends for iron pipe, isi marked, all as specified and directed for the following bore dia of pipe:-(a) 15mm bore. 119 (b) 20mm bore. 120 (c) 25mm bore. 121 s&f 25/32mm bore ball valve high pressure of ptmt with epoxy coatedaluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms), complete all as specified and directed. 122 s&f 20mm bore ball valve high pressure of ptmt with epoxy coatedaluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms), complete all as specified and directed. 123 s&f 15mm bore ball valve high pressure of ptmt with epoxy coatedaluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 142 gms), complete all as specified and directed. 124 supply only liquid water proofing compound, complete all as specified and directed. 125 s&f in repair for stainless steel wire cloth 0.36nominal dia of wire and average width of aperture 1.4mm and fixedwith stainless steel staple to wooden / steel frames, complete all as specified and directed
  • View Tender
  • Document
  • Bid Support
9 Power
image image
State Government
TRN :49057999 |  23 May, 2025
Tender Value : 0
 Ghaziabad - Uttar Pradesh
Tender for tender for construction of civil works for increasing capacity from (1x500 plus 2x315 mva) to (2x500 plus 1x315 mva) at 400 k.v. sub-station-ist muradnagar ghaziabad. - earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) all kinds of soil including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by engineer-in-charge. 2 excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all 3 providing and laying in position cement concrete of specified grade 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)excluding the cost of centering and shuttering - all work up to plinth level : 4 providing and laying in position cement concrete of specified grade 1:5:10 (1 cement : 5 coarse sand (zone-iii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)excluding the cost of centering and shuttering - all work up to plinth level : 5 providing and laying in position cement concrete of specified grade1:1½:3 (1 cement: 1½ coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 6 providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 7 centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete 8 centering and shuttering including strutting, propping etc. and removal of form for walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 9 centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform 10 centering and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts. 11 providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 12 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500d or more. 13 brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,t&p etc complete . 14 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand). 15 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand). 16 dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with jamuna sand, with common burnt clay non modular bricks 17 supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer-in-charge . 18 structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 19 mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof workgates etc. wrought to required form including holes rivetting or welding where necessary and also fixingin proper position and alignment but when steel is to be provided by the department . 20 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand). 21 extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 22 extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 23 neat cement punning 24 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 25 demolishing cement concrete (nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 26 demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 27 dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 28 demolishing r.c.c. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. 29 dismantling of existing pale / security / chain link fencing including post and stacking properly as per direction of the engineer - in - charge. including all labour and t&p etc. required for proper completion of the work 30 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 31 supply of 25 mm. dia m.s. anchor bolts (conforming to is 266)500 mm. long with base plate (50x50x6mm) welded with anchor boltsincluding its threading upto a length of 10cm. and also supplyof a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & t&p for proper completion of work 32 fixing and grouting 25 mmand below dia m.s. anchor bolt in proper alignment level and setout with the help of a template including supply of all labour t&p etc. reqd. for proper completion of the work. (labour rates only) . 33 grouting of 90/105 lbs m.s. railincluding cost of all materials,labour & t&p for fixing of rail in proper alignment, leveland position in transformer plinth foundation etc. as perdirection of eng i/c. (rail to be supplied by thedept.)(labour rates only) . 34 s/f in position 105 lbs m.s. rail for transformer plinth including cost of all labour, material and t&p etc. required for proper completion of the work. 35 fixing and grouting of trench edging in proper level and alignment including cost of all labour, and t&p etc. required for proper completion of the work but excluding cost of c.c. (labour rates only) . 36 fixing of template in position level and alignment for groutingof anchor bolt in auxiliary gantry (labour rate only). 37 fixing of cable trench racks in proper position and alignment including cost of all labour, material and t&petc. required for proper completion of the work (labour rate only). 38 fabrication of template forauxiliary foundation including cost of all labour, and t&p etc. required for proper completion of the work. steel shall be arranged by contractor free of cost. this template shall be property of contractor.(labour rate only). 39 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm gradedapproved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement andmarble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels ifany and giving them a uniform finish including supply of all materials, labour and t&p etc, required forproper completion of the work. without base cc 40 placing of trench cover of all size in proper position including transportation from different places withinthe s/s area including all labour, t&p etc. required for proper completion of the work as per direction ofengineer - in - charge. 41 preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. 42 providing and laying swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work (110mm dia pipe) 43 providing and laying design mix cement concrete of m-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy m.s. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of engineer-incharge (item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).cement concrete manufactured in automatic batching plant (rmc plant) i/c transportation to site in transit mixer 44 providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood pre-laminated one side decorative lamination and other side balancing lamination grade i, type ii, is : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete : (12mm thick partical board) 45 hiring of beldar(labour).
  • View Tender
  • Document
  • Bid Support
10 Education And Research Institutes
image image
State Government
TRN :49060976 |  30 May, 2025
Tender Value : 2.00 Lacs
 Prayagraj - Uttar Pradesh
Tender for tender for supply of stationery items; 1 allpin 50 gram per box 2 ball pen ordinary 3 ball pen superior 4 ball pen use & throw 5 bamboo paper size 29”x44” 6 binder clip 51 mm(12 pcs) 7 black board duster per pcs 8 boardpin (50 pcs per box) 9 box file superior laminated 10 butter paper (tracing paper ) size 49cm x 74cm 11 cadek board file 12 cadek patti 13 call bell (battery operated) 14 candle 15 carbon paper fs 100 sheets 16 cash book 17 cash book 1qr size 8”x13” 18 cash book 2qr. size 8”x13” 19 cash book 4qr. size 8”x13” 20 casio calculator 10 digit 21 casio calculator 12 digit 22 cello tape / brown tape 1x65 mtr 23 cello tape / brown tape 2x65 mtr 24 chalk dustless colored per box 25 chalk white dustless per box 26 chalk white ordinary per box 27 chart paper white / colored size 55cmx70cm 28 clip board fiber a4 size 29 clip board ordinary a4 size 30 colored paper a4 80 gsm 31 correction pen camlin 32 cover plastic a4 (100 pcs ) 33 cover plastic legal (100 pcs) 34 dispatch register 2 qr. size 8”x13” 35 double button file 36 drawing sheet full size 55cmx70cm 37 dustbin with cover 38 dustbin without cover 39 envelop clothing brown 10x12 inch per 100 40 envelop clothing brown 11x5 inch per 100 41 envelop clothing brown 16x12 inch per 100 42 envelop clothing brown 16x6 inch per 100 43 envelop clothing brown 8x10 inch per 100 44 envelop plain brown 16x12 inch per 100 45 envelop plain brown laminated 12x10 inch per 100 46 envelop plain white 10x4.5 inch per 100 47 envelop plain white 11x5 inch per 100 48 envelop plain white 6x3.5 inch per 100 49 envelop plain white 9x4 inch per 100 50 eraser natraj 51 fevibond 50ml 52 fevicol glue stick 15 gm 53 fevicol tube100gm 54 feviquick 15 gram 55 feviquick 500 mg 56 file cover bamboo 57 file cover card sheet 58 file cover hand made 59 file tray double rack superior 60 file tray single rack ordinary 61 file tray single rack superior 62 file tray tripple rack superior 63 floor duster (12x18) 64 four flap file good quality 65 graph paper 20”x30” size (per 100) 66 graph paper a4 size (per 100) 67 gum bottle elephant 300ml 68 gum bottle elephant 700ml 69 highlighter pen 70 hilighter 71 lai ( packet of 10 pcs) 72 lecture attendance register size 8”x13” 73 ledger book 2 qr. size 8”x13” 74 ledger book 4 qr. size 8”x13” 75 link lock 55 76 link lock 60 77 link lock 65 78 link lock 70 79 lock (godrej) 3 ton nav-tan altra xl brass 80 log book (for vehicle) 81 log table (mathematical) 82 ohp transparent film 100 sheet 83 page marker 84 paper cutter knife big 85 paper cutter knife small 86 paper knife big 87 paper weight egg shape 88 paper weight ordinary 89 paper weight superior 90 pen stand double pen (with pen) 91 pen stand single pen (with pen) 92 pencil natraj hb ( packet of 10 pcs) 93 peon book 94 permanent board marker camlin 95 permanent cd marker camlin 96 permanent marker ink camlin 97 photostat paper jk red a3 75 gsm 98 photostat paper jk red a4 75 gsm 99 photostat paper jk red fs 75 gsm 100 pin cushion 101 plain paper per qr. size 7”x12” 102 plastic l folder file(12pcs) 103 poker(suja) with wooden handle 104 pos machine roll big 105 pos machine roll small 106 punching machine kangaro double hole (small) 107 punching machine kangaro heavy duty 108 punching machine kangaro single hole 109 register 1qr. size 8”x13” 110 register 2qr. size 8”x13” 111 register 3qr. size 8”x13” 112 register 4qr. size 8”x13” 113 register 6qr. size 8”x13” 114 register size 12”x15” (200pg) 115 rubber band nylon ( per100 gram) 116 ruled paper per qr. size 7”x12” 117 scale plastic 12 118 scale steel 12 119 scissor big 120 sealing wax per box 121 sharpener natraj 122 sketch pen ( packet of 10 pcs)single colour 123 sony dvd in 100 pack 124 sony dvd in jewel case 125 spiral register 200pg 126 spiral ring all size (rate per kg) 127 stamp pad ink 30ml camlin 128 stamp pad large camlin 129 stamp pad medium camlin 130 stapler big kangaro no.555 131 stapler big kangaro no.hp45 132 stapler heavy duty kangaroo no. 23/17 133 stapler kangaro hp10 big 134 stapler kangaro no.10 135 stapler pin big kangaro no.23/17 136 stapler pin big kangaro no.24/6 137 stapler pin small kangaroo no.10 138 stock register 2qr. size 8”x13” 139 stock register 3qr. size 8”x13” 140 stock register 4qr. size 8”x13” 141 accession register 142 periodic record register 143 book issue register 144 visitor book 145 staff /teachers book issue register 146 contingency book register 147 sutli jute ( rate per kg) 148 sutli plastic ( rate per kg) 149 table bell 150 table name plate 151 tag big (per lacchi) 152 tag file bamboo paper (with college name printed) 153 tag file handmade paper (with college name printed) 154 thread (per 200 gram) 155 t-pin 50 gram per box 156 trimax gel pen 157 trimaxgold pen 158 upin (50 pcs per box) 159 wall clock 160 water spunj 161 white board duster per pcs 162 white board marker ink camlin 163 white board marker pen camlin 164 writing pad big size 10”x4” 165 writing pad medium size 9”x13” 166 bluetooth adopter 167 cat 6 cable (per mtr.) 168 cmos battery 169 desktop hard disk internal 1 tb 170 d-link switch 8 port 171 hard disk external 1 tb usb 3.0 172 hard disk external 1 tb usb 3.0 173 hdmi cable 10mtr 174 hdmi cable 20mtrl 175 hdmi cable 5 mtr 176 head phone 2 pin 177 head phone usb 178 key-board & mouse combo (wired) hp & dell 179 key-board (wired) hp & dell 180 modem router (single band) 181 monitor screen 18.5” led 182 mouse combo (wired) hp & dell 183 pen drive 32 gb 184 pen drive 64 gb 185 power cable 1.5 mtr. 186 printer cable 1.5 mtr. 187 printer cable 5 mtr. 188 printer streaming switch 189 quick heal total security new pack (10 user 1 year) 190 quick heal total security new pack (10 user 3 year) 191 quick heal total security new pack (3 user 1 year) 192 quick heal total security new pack (3 user 3 year) 193 quick heal total security new pack (5 user 1 year) 194 quick heal total security new pack (5 user 3 year) 195 quick heal total security new pack (single user 1 year) 196 quick heal total security new pack (single user 3 year) 197 quick heal total security renewal pack (10 user 1 year) 198 quick heal total security renewal pack (10 user 3 year) 199 quick heal total security renewal pack (3 user 1 year) 200 quick heal total security renewal pack (3 user 3 year) 201 quick heal total security renewal pack (5 user 1 year) 202 quick heal total security renewal pack (5 user 3 year) 203 quick heal total security renewal pack (single user 1 year) 204 quick heal total security renewal pack (single user 1 year) 205 quick heal total security renewal pack (single user 3 year) 206 r.j. 45 connector 207 smps desktop pc 24 pin 208 ups 600 va 209 ups battery exide 210 usb extension cable 1.5 mtr (male-female) 211 usb extension cable 5 mtr (male-female) 212 vga cable 5 mtr. 213 vga cable 10mtr. 214 vga cable 20mtr. 215 hdmi cable 5 mtr. 216 hdmi cable 10mtr. 217 hdmi cable 20mtr. 218 web cam usb 219 wi-fi adopter 220 cottage paper full sheet 221 water colour set (camel) 222 oil sheet full sheet 223 oil colour set camel 224 hand made paper (for water colour) full sheet. 225 acrylic colour set (camel) 226 drawing pencil set 227 canvas roll (camel) 228 whitener pen 229 easel wooden normal size
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • 4
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : security wall
  • Wall Paneling Repair Tenders ,
  • Safety Wall Repair Tenders ,
  • Parapet Wall Tenders ,
  • Rcc Wall Repair Tenders ,
  • Gabion Box Tenders ,
  • Wall Tiling Work Tenders ,
  • Block Wall Tenders ,
  • Partition Wall Repair Tenders ,
  • Gabion Tenders ,
  • Kerb Wall Repair Tenders

Get security wall Tender Alert...

750445

Related Searched Keywords : security wall

  • Causeway Bridge Tenders From Maharashtra
  • Interlock Paver Tenders From Delhi
  • False Ceiling Repair Tenders From West-Bengal
  • Sewer Lines Tenders From -Tamil-Nadu
  • Grouting Tenders From Andhra-Pradesh
  • Acoustic Work Tenders From Gujarat
  • Railway Under Bridge Tenders From Karnataka
  • Irrigation Works Tenders From Uttar-Pradesh
  • Tile Works Tenders From Rajasthan
  • Pile Foundation Tenders From Madhya-Pradesh

Read More


Tender Document

066146

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Site Preparation Work Tenders
  • Grouting Work Tenders
  • Stone Cladding Tenders
  • Table Tenders
  • Earth Filing Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App