Tender for stage contract for sub division anantnag.- stage contract anantnag sub division. 2 engagements of jcbfor execuation of works of various natures 3 surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -all kinds of soil 4 earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed,( all kinds of soil) 5 earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by engineer-in-charge. all kinds of soil : 6 earth work in excavation by manualmeans in trenches for foundations, drains, pipes, cables etc .upto required depth ) and for shafts, wells, cesspits including dressing of sides and ramming of bottoms , including getting out excavated earth and disposal of surplus excavated earth as directed,( all kinds of soil) 7 supply and filling of rbm of specified size including spreading, watering, ramming, compacting with prr of 8 to 10 tonne capacity and including carriage of the same from approved source upto site of work complete 8 felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. 9 beyond 30 cm girth upto and including 60 cm girth. 10 beyond 60 cm girth upto and including 120 cm girth. 11 beyond 120 cm girth upto and including 240 cm girth. 12 banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or xt-red-selected">steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soi 13 supply and filling of khak bajri including spreading, watering, ramming, compacting with prr of 8 to 10 tonne capacityincluding carriage of the same from approved source upto site of work complete( for berm) 14 providing / laying of rcc pipes in proper position/ grade including cutting of road surface upto required depth, providing requisite cushion including carriage ofall materials and pipesupto site ofwork complete. 15 10 16 12 17 14 18 16 19 20 20 24 21 32 22 36 23 40 24 48 25 providing / laying of ms pipes in proper position/ grade including cutting of road surface upto required depth, providing requisite cushion including carriage ofall materials and pipesupto site ofwork complete. 26 6 27 8 28 10 29 12 30 scarifying the existing bituminous road surface to a depth of 50mm and disposal of scarified material within all lifts and lead upto 1 km (by mechanical means). 31 scarifying metalled (water-bound) road surface including disposal of rubbish lead upto 50m and consolidation of the aggregate received from scarifying with power road roller of 8 to 10 tonne capacity. 32 providing and laying water bound macadam base course with quarry crushed stone aggregate 90 to 45mm size, stone screening 13.20mm size and binding material as per morth specification including screening, sorting, spreading to template and consolidation with prr of 8 to 10 tonne capacity including carriageofquarry crushedstone aggrregateand stone screeing, stone dustfrom approved soucrce upto site of wotk complete(finished work to be measured) 100mm compacted thickness 33 providing and laying water bound macadam base course with quarry crushed stone aggregate 63 to 45mm size, stone screening 13.20mm size and binding material as per morth specification including screening, sorting, spreading to template and consolidation with prr of 8 to 10 tonne capacity including carriageofquarry crushedstone aggrregateand stone screeing, stone dustfrom approved soucrce upto site of wotk complete(finished work to be measured) 75mm compacted thickness 34 providing and laying water bound macadam base course with quarry crushed stone aggregate 53 to 22.4mm size, stone screening 11.20mm size and binding material as per morth specification including screening, sorting, spreading to template and consolidation with prr of 8 to 10 tonne capacity including carriageofquarry crushedstone aggrregateand stone screeing, stone dustfrom approved soucrce upto site of wotk complete(finished work to be measured) 75mm compacted thickness 35 providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (wmm) specification including premixing the material with water at omc in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of engineer-in-charge 36 providing and applying tack coat using hot straight run bitumen of grade –vg-10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. on bitumen surface @ 0.50 kg/sqm 37 providing and applying tack coat using hot straight run bitumen of grade –vg-10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. on w.b.m. @ 0.75 kg/sqm 38 providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of engineer-in-charge. 50 to 100 mm average compacted thickness with bitumen of grade vg-10 @ 3.5% (percentage by weight of total mix) 39 providing and laying semi- dense bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of engineer-in-charge. 25 mm compacted thickness with bitumen of grade vg 10 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of aggregate) 40 providing and laying dense graded bituminous macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of engineer-in-charge. 16.62.1 50 to 100 mm average compacted thickness with bitumen of grade vg-30 @5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of aggregate) prepared in batch type hot mix plant of 100-120 tph capacity. 16.62.2 50 to 100 mm average compacted thickness with bitumen of grade vg-30 @5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of aggregate) prepared in drum type hot mix plant of 60-90 tph capacity. 41 providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade vg-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road all complete. 42 providing and laying of stone soling, hand packed, including carriage of same from approved source upto site of work complete. 43 providing and laying in position cement concrete in1 : 4 : 8 (1 cement :4 coarse sand : 8 graded crushed stone aggregate, 40mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. 44 providing and laying in position cement concrete in1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate, 40mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. 45 providing and laying in position cement concrete in1 : 2 : 4 (1 cement :2 coarse sand : 4 graded crushed stone aggregate, 20mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. 46 providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. but including carriage of all materials from approved sources up to site of work complete.all works upto plinth level (1: 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 47 providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. but including carriage of all materials from approved sources up to site of work complete.all works upto plinth level (1 : 2 : 4 (1 cement :2 coarse sand : 4 graded crushed stone aggregate, 20mm nominal size)) 48 reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.but including carriage of all materials from approved sources up to site of work complete. (1: 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 49 reinforcement for rcc work including straightening cutting, bending, placing in position and binding all complete (thermo mechanically treated bars) including all carriages complete. fe-500 d or more 50 providing / fixing of necessary farm work / shuttering including strutting, propping etc and removal of same complete 51 foundations, footings, bases for columns 52 return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc. 53 suspended floors, roofings, landings, balcones and access plateform 54 50mm thick cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished wit a floating coat of neat cement including carriage of all materials from approved sources upto site of work complete 55 40mm thick cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished wit a floating coat of neat cement including carriage of all materials from approved sources upto site of work complete 56 25mm thick cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished wit a floating coat of neat cement including carriage of all materials from approved sources upto site of work complete 57 12mm cement plaster of mix 1:4 (1cement: 4 fine sand) including all carriages complete. 58 12mm cement plaster of mix 1:6 (1cement: 6 fine sand) including all carriages complete. 59 15mm cement plaster of mix 1:4 (1cement: 4 fine sand) including all carriages complete. 60 15mm cement plaster of mix 1:6 (1cement: 6 fine sand) including all carriages complete. 61 dry random rubble masonry in 100 x100mm mesh size g.i wire crate made of 5mm dia g.i wire using bond stones ncluding wrapping /tightening of wire crate and binding wire crates after stone work including cost of all material involed (crates and stones) and carriage of same upto site work complete (quarry stones) 62 random rubble masonry with hard stone (quarry) in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarsesand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of all materials from approved sources up to site of work complete. 63 engagement of labour /masdoor for one day 64 engagement of skilled labour with all machinary like cutters , axe etc for purning of the trees 65 pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 66 removal of unhygienic materials (so classified by the site engineer) from designated sites and its disposal as per directions, all inclusive 67 clearance of slipsdisposal lead upto 50 m and lift upto 1.5 m. 68 in ordinary soils disposal lead upto 50 m and lift upto 1.5 m. 69 in soils; mixed with moorum/kankar/shingle/boulders; disposal lead upto 50 m and lift upto 1.5 m. 70 in soils; mixed with decomposed rocks; by blasting or any other means 71 providing and applying 2.5mm thick road marking strips (retro-reflective) of specified shade/colour using hot thermoplastic material by fully/semiautomatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreignmaterial etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 72 white washing with lime to give an even shade :old work (two or more coats) 73 white washing with lime to give an even shade :old work (one or more coats) 74 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work 75 painting road surface marking with adequate no. of coats to give uniform finish with read mixed road marking paint conforming to is: 164, on bituminous surface in white/yellow shade including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.old work ( one or more coats) 76 providing and laying at or near ground level factory made kerb stone of m-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-incharge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 77 manufacturing supplying and fixing retro reflective sign boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type-iv of astm-d-4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per irc : 67-2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of astm-d-4956-01 and fixing the same with suitable sized aluminum alloy rivets @ 20cm c/c to back support frame of m.s. angle iron of size 25x25x3mm along with theft resistant measures mounted and fixed with 2 nos. m.s. angles of size 35x35x5mm to a vertical post made upto m.s. tee section ismt 50x50x6mm welded with 16.0 (road work) 224 base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angle flats, providing and fixing m.s. message plate of required size xt-red-selected">steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical m.s.-tee support to be painted in black and white colours). backside of aluminum sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coats including all leads and lifts etc. complete as per drawing, specification and direction of engineer-in-charge. 16.66.1 mandatory/regulatory sign boards of 900 mm diameter with part as length of 3750 mm. 78 structural xt-red-selected">steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved xt-red-selected">steel primer all complete 79 structural xt-red-selected">steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved xt-red-selected">steel primer all complete. welded 80 supply and filling of rbm of specified grade including spreading, watering, ramming, compacting with prr of 8 to 10 tonne capacity material availabe at site
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed xt-red-selected">steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed xt-red-selected">steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) xt-red-selected">steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless xt-red-selected">steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos xt-red-selected">steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild xt-red-selected">steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild xt-red-selected">steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild xt-red-selected">steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild xt-red-selected">steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild xt-red-selected">steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless xt-red-selected">steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild xt-red-selected">steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to xt-red-selected">steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless xt-red-selected">steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild xt-red-selected">steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi xt-red-selected">steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg msxt-red-selected">steel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless xt-red-selected">steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural xt-red-selected">steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless xt-red-selected">steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : xt-red-selected">steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless xt-red-selected">steel ss304 with honey comb finish 118 false ceiling finish : stainless xt-red-selected">steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless xt-red-selected">steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless xt-red-selected">steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless xt-red-selected">steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless xt-red-selected">steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless xt-red-selected">steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless xt-red-selected">steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless xt-red-selected">steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless xt-red-selected">steel (c) car operating panel of stainless xt-red-selected">steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless xt-red-selected">steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small xt-red-selected">steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) xt-red-selected">steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe xt-red-selected">steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless xt-red-selected">steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless xt-red-selected">steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed xt-red-selected">steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild xt-red-selected">steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground xt-red-selected">steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild xt-red-selected">steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized xt-red-selected">steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled xt-red-selected">steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all xt-red-selected">steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon xt-red-selected">steel shaft with common base frame (fabricated mild xt-red-selected">steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the xt-red-selected">steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized xt-red-selected">steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron xt-red-selected">steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the xt-red-selected">steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless xt-red-selected">steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, xt-red-selected">steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised xt-red-selected">steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless xt-red-selected">steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring xt-red-selected">steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild xt-red-selected">steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless xt-red-selected">steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless xt-red-selected">steel type main agitator shaft: stainless xt-red-selected">steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
Tender for tender for provn of fencing and gate at af stn deesa (ph-ii); 1 b/r works 2 site clearance of area including shrubs, vegetation, grass, bush, weed, trees and saplings n. exc. 30 cm girth complete all as specified and directed. 3 excavating in post hole each n exc. 0.50 cum, getting out in soft/loose soil including returning, filling in and ramming earth or broken rubble mixed with earth around, in layer not exc. 25 cm, watering including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots and trees n. exc. 30 cm girth (measured one meter above ground level) and removing rubbish/ surplus soil upto a distance of 50 meters outside and making good surface complete all as specified and directed.note : necessary dewatering of water if requried shall be included in the unit rate of item. 4 excavation in trenches, n nexc 1.5m wide and n. exc 1.5 m in depth, for foundation manholes, wells, drain etc.getting out in soft/loose soil including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots and trees n. exc. 30 cm girth (measured one meter above ground level) and removing rubbish/ surplus soil upto a distance of 50 meters outside complete all as specified and directed. 5 m & l for cement concrete 1:2:4 type b-1 (20 graded stone aggregate) as in post holes includingcompaction by vibratorcomplete all as specified and directed. 6 m & l for cement concrete 1:4:8 type d-2 ( 40 mm aggregate)in foundations, filling and mass concrete complete all as specified and directed. 7 s & f mild xt-red-selected">steel work as in fencing posts and struts in fencing including cutting tops of shape as directed, drilling holes, notching for wire, etc.,flat iron fillets and round bars with hooks at ends (for securing wire mesh etc.) incl all necessary drilling, bolting or riveting, etc, and similar work confirming to fe -290 gde e-165 complete all as specified and directed. 8 supply only chain link ms galvanised fencing, any size or type complete all as specified and directed. note :i) chain link of mesh size preferably 100 mm mesh 10 gauge thickness will be provided, however the size may be changed after written approval of ge.ii) the weight of chain link fencing shall be ascertained by boo ordered by ge 9 fixing only chain link fencing including line wires,any mesh,size and type to any type of standards,rails,straining bolts,etc. including provision of binding wire complete all as specified and directed. note : chain link of mesh size preferably 100 mm mesh 10 gauge thickness will be provided,howeverthe size may be changed after written approval of ge. 10 s & f 5-10 mm diameter of shank mild xt-red-selected">steel screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other,or screwed both ends.each screwed end to be fitted with washers and one hexagonal or square nut, n exc. 5 cm long complete all as specified and directed. 11 m & l for mild xt-red-selected">steel work 10 mm dia round bars as in fencing cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild xt-red-selected">steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 12 s & f galvanised. 2 strand, xt-red-selected">steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild xt-red-selected">steel wire, staples or xt-red-selected">steel pins, complete all as specified and directed. (each line wire to be measured) 13 material & labour for 610 mm dia punched tape concertina coil fencing stretches ( supporting wire of the same material as concertina coil ) having stranding specifications average weight not less than 1.06 kg/m incl coating of px2 compound (anti rust) and fixed in angle iron brackets on compound wall/ fencing with and including all scaffolding if required complete all as specified and directed. 14 m&l preparation of new xt-red-selected">steelsurfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 15 m & l for new xt-red-selected">steel primed surfaces of any description, n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 16 m&l brick work with sub class b bricks straight or curved on plan exceeding 6m mean radius bulit in cm 1:6 complete all as specified and directed. 17 m&l for cement concrete (1:2:4) type b-0 using 12.5 mm graded aggregate as incopingetc. including weathering, slighty rounded or chamfered angle including necessary form work complete all as specified and directed. 18 m&l rendering 10mm thickin cement mortar 1:6 on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. 19 m & l, two coats of cement based paint over one coat of alkali resistant primer in including preparation of new surface (preparing surfaces plastered or unplastered) on internal wall complete all as specified and directed. 20 s&f 110 mm bore pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls as in weep holes complete all as specified and directed. 21 m&l rcc m-25 (20mm graded aggregates) work as in foundation, including rafts, footing beam etc. complete all as specified and directed. 22 m&l rcc m-25 (20mm graded aggregates) work as in columns, pillars, piers, post and struts etc. complete all as specified and directed. 23 m & l for form work to side of concrete foundation, footing, bases of columns, raft sides and soffits (if any) of foundation and plinth beams with fair finish surface etc.complete all as specified and directed. 24 m & l for form work to sides of column with fair finished surface of concrete etc complete all as specified and directed. 25 m & l for mild xt-red-selected">steel bars (tmt) 10 mm dia and over, cut to lenth bent to shape required, including cranking bending spirally for hooping for columns hooking end and binding with xt-red-selected">steel wire or sequring with clips complete all as specified and directed. 26 m & l for mild xt-red-selected">steel bars (tmt) 8 mm dia and over upto and including 10 mm dia in stirrups, spaces and binder as in column complete all as specified and directed. 27 s&f xt-red-selected">steel sections fe-290(gde-e-165) forframed work as in doors or gates of angle or other section with gusset plates , rails, braces with ornamental and intricate design complete,drilled for fixing of xt-red-selected">steel sheeting or other covering. door, etc to be prepared for hanging or sliding with and including either hooks and hinges or xt-red-selected">steel hanging door fiftting (exc. of xt-red-selected">steel sheeting or other covering ,running rails and guides ) and hanging ; also fastening and fixing complete all as specified and directed. 28 m& l 20mm thick granite (of any type) work in steps, jambs,clading topillars, window-cills, cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite and 20mm thick screed bed in cm 1:4 complete all as specified and directed. 29 returning, filling in, including spreading, levelling, watering and well ramming in layer not exc 25 cm complete all as specified and directed. 30 rough excavation not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed. 31 forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/ rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed. 32 removing excavated material ( soil ) exc 250m but n. exc. 500mand depositing where directed complete all as specified and directed. 33 m&l framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar workconforming to fe.290.gde-e-165 complete all as specified and directed. 34 e/m works 35 s & fjunction boxes madeup of crca sheet 2 mm thick of the 300 mm x 300 mm x 150 mm complete all as specified and directed. 36 s & f rigid non-metallic pvc conduit 20 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. 37 s & f for galvanised of 50 mm bore tubes, light grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Tender for tender for structural strengthening and external painting of b e college t e howrah; 1 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2 nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 3 dismantling doors, windows and clerestory windows (xt-red-selected">steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 4 of area 3 sq. metres and below 5 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 6 for thickness of tiles 10 mm to 25 mm 7 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 8 up to 150 mm diameter 9 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 10 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 11 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 12 1:2:4 (1 cement : 2 coarse sand(zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 13 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 14 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 15 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 16 reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii)derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). 17 centering and shuttering including strutting, propping etc. and removal of form for : 18 foundations, footings, bases of columns, etc. for mass concrete 19 columns, pillars, piers, abutments, posts and struts 20 vertical and horizontal fins individually or forming box louvers band, facias and eaves boards 21 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 22 smooth finishing of the exposed surface of r.c.c. work with 6 mm thick cement mortar 1:3 (1 cement : 3 fine sand). 23 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 24 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 25 providing and fixing to existing door frames. 26 30 mm thick glass fibre reinforced plastic (frp) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick frp laminate for panels conforming to is: 14856, including fixing to frames. 27 xt-red-selected">steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved xt-red-selected">steel primer using structural xt-red-selected">steel etc. as required. 28 in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 29 providing and laying rectified glazed ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to is : 15622, of approved make, in colours white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 30 providing and fixing on wall face unplasticised - pvc moulded fittings/accessories for unplasticised rigid pvc rain water pipes conforming to is 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 31 single tee with door -110x110x110 mm 32 bend 87.5° -110 mm bend 33 15 mm cement plaster on the rough side of single or half brick wall of mix : 34 1:6 (1 cement: 6 fine sand) 35 finishing walls with acrylic smooth exterior paint of required shade : 36 new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 37 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 38 two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 39 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 40 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 41 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°c, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 350/300 n/5 cm. tear strength in longitudinal and transverse direction as 60/80n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 42 3 mm thick 43 providing and fixing white vitreous china pedestal type (european type/ wash down type) water closet pan. 44 providing and fixing p.v.c. low level flushing cistern with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete. 45 10 litre capacity - white 46 providing and fixing solid plastic seat with lid for pedestal type w.c. pan complete : 47 white solid plastic seat with lid 48 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 49 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete. 50 flexible pipe -32 mm dia 51 providing and fixing ptmt bib cock of approved quality and colour. 52 15mm nominal bore, 86 mm long. weighing not less than 88 gms. 53 providing and fixing ptmt stop cock of approved quality and colour. 54 15 mm nominal bore, 86 mm long. weighing not less than 88 gms. 55 providing and fixing ptmt pillar cock of approved quality and colour . 56 15mm nominal bore, 107 mm long. weighing not less than 110 gms. 57 providing and fixing unplasticised p.v.c. connection pipe with ptmt nuts, collar and bush of approved quality and colour. 58 15 mm nominal bore with 45 cm length. 59 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 60 75 mm average thickness 61 50 mm average thickness 62 25 mm average thickness 63 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free xt-red-selected">steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 64 bars upto 12 mm diameter 65 bars above 12 mm diameter 66 providing, mixing and applying bonding coat of approved adhesive on chipped portion of rcc as per specifications and direction of engineer-in-charge complete in all respect. 67 sbr polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer 68 providing, mixing and applying sbr polymer (of approved make) modified cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of engineer-in-charge. note: measurement and payment: the pre-measurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 n/sqmm2). 69 12 mm average thickness. 70 25 mm average thickness in 2 layers. 71 50 mm average thickness in 3 layers. 72 providing and fixing upvc pipes (sch 40 upvc as per astm d- 1785 pipes) including all upvc plain and brass threaded fittings. including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step upvc solvent cement and testing of joints complete as per direction of engineer in charge. internal work- exposed on wall 73 15 mm nominal bore 74 20 mm nominal bore 75 25 mm nominal bore 76 uprooting and removing small plants from the surface of walls, parapet, etc. at any height by cutting chase for removing roots and using necessary chemicals etc. to prevent further growth of plants and mending good damages complete. 77 a) small plant of girth of exposed stem up to 75mm 78 providing and fixing soil waste and vent pipes : 79 110 mm dia upvc soil waste pipe conforming to is:13592 1992 (type-b) manufactured by supreme industries limited or equivalent. 80 erection of single layer bamboo-scaffolding made of average 75 mm dia bamboos with adequate bracing, ties, ropes etc. for strong, stable and workable scaffolding for specified jobs ( above gf beyound 4.00m height) like replacement of sewage/ rw pipes & accessories, repairs to plasters, special repairs, replacement of glass panes, uprooting/ cutting of tree saplings etc including dismantling the scaffolding after the job is done and clearing the site complete as per the direction of the engineer-in-charge. [ projected area of scaffolding frame work on buiding elevation to be measured for payment] 81 felling of trees like banyan, pipul etc from compound walls, building walls, cornices etc by making scaffolding where necessary including cutting of trunks and branches, application of chemicals/weedicides to the remaining portion to kill the growth of tree and ultimately removing the roots from the walls by cutting walls and mending good complete. ( the rate is inclusive of the mending good the walls with bricks/concretes/plasters and disposing of branches/trunks to vats inside compound for further disposal) 82 a) of girth above 30 cm upto 60 cm (measured above 1.0 m from gl toupto 5.0 m height) 83 extra for shifting of existing scaffolding by lifting/dragging or partially dismantling and re-erecting the dismantled portion in position (shifting at least 1.50 m from initial centre line of position) over payment for initial erection & dismantling paid in original item of scaffolding. [ projected area of scaffolding frame work on buiding elevation to be measured for payment] 84 providing and fixing ptmt health faucet with hook and p.v.c. pipe (1.00 metre minm length) of approved quality and colour in w.c.s all complete as per direction of engineer-in-charge. 85 15 mm nominal bore with minimum 1.00 m pvc tube. 86 attending repairs to ms gate by removing corroded portion of gate with welding machine at site and replacing with new members as per actual requirement at site. (cost for labour and hire charges of welding machine including transporation, consumables. xt-red-selected">steel members will be paid separately) 87 providing and welding 2mm thick m.s. sheet to existing m.s. frame work including providing and appying a priming coat of approved xt-red-selected">steel primer all complete. 88 providing and fixing upvc floor trap 100mm dia inlet and 100 mm dia outlet. 89 providing and fixing ptmt 2 way bib cock of approved quality and colour, for fixing hand faucet in commode toilets all complete as per direction in charge.- 15mm nominal bore. 90 supplying, fitting and fixing in position fibre glass panes of approved quality with resin, nail, clip etc. as per is:12866-1989. 91 4.0 mm thick (6.72 kg/sq.m) 92 credit value for dismantled unserviceable mild xt-red-selected">steel/ iron materials. 93 credit value for dismantled g.i. pipes: 94 15 mm nominal dia. 95 20 mm nominal dia. 96 25 mm nominal dia. 97 credit value for dismnatled c.i./ s.c.i. pipes. 98 credit value for unserviciable brass bib/stop cocks/pillar tap
Tender for rate call for ( non dsr) items preparing estimate of under honble balasaheb thackeray haridra research and traning centre,vasmat,dist.hingoli =2 providing & fixing on site 75 mm thick reflexology ( pebbles ) stone flooring etc complete 3 providing & laying of hdpe pond liner of 750 micron thickness as per manufacturer’s specification & instructions from engineer in charge etc. complete. 4 orientation signage pole :- providing & fixing of orientation signage pole made up of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), with the size of 12x4inner frame and 60mm dia for support structure made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. the structure will be illuminated from within. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 5 identification signage pole :- providing & installation of identification signage pole made up of marine quality composite from 60mm dia for support structure {marine grade corrosion resistant & hydrocarbon solvent resistant) with all fittings fixture, hardwares , all as per design & drawings with all fittings, fixtures etc. complete , with the size of 6x1.5inner frame made of mild xt-red-selected">steel pipe od 60mm as the main support section is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 6 directional signage -5m single arm frp pole with haldi banner and leaf (signage): the single arm pole shall be made of 68 mm dia with metal hot dipped galvanized pipe support inside the frp cladded pole. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of is:3601 or equivalent, hotdip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted which usually require maintenance and care. pride suspended luminaire: 50 watt led suspended luminaire with height 450mm and width 500mm. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 7 directional signage post :-providing & fixing of directional signage post (signage) with 5ft height and 700mm wide post and 48 mm dia support pipe with frame having and metal frame to show the directional or location of certain area. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer incharge etc. complete on site. structural stability certificate will be givenv 8 haldi information post :- providing & fixing of haldi information post- farming (signage) with 5ft height and 700mm wide and 48 mm dia support pipe with frame having a metal frame work to be used for provided information regarding the harida haldi project and which type of haldi crop grown on the particular field. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. item is also including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete. 9 pergolas type 1:- providing & fixing of type 1 pergolas with frp column 200mm x 200 mm in ms fabrication use in 88.2 od ms pipe 3 mm thickness. frp beam size 150 mm x 150 mm in ms fabrication 40 mm x 40 mm x 2 mm thickenss tube in framing. frp support for beam and column use in 75 mm x 75 mm x2 mm ms tube with frp cladding. frp thickness minimum 3 to 4 mm . column fittng in 12 mm x 150 mm anchor bolt in foundation. including installation machineries, scaffoldings, electricity, other site utilities in client scope. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structure stability certificate will be provided etc complete 10 pergolas type 2( for seating areas ):- providing & fixing of type 2 with frp column 200mm x 200 mm in ms fabrication use in 88.2 od ms pipe 3 mm thickness . frp beam size 150 mm x 150 mm in ms fabrication 40 mm x 40 mm x 2 mm thickness tube in framing. frp support for beam and column use in 75 mm x 75 mm x2 mm ms tube with frp cladding. frp thickness minimum 3 to 4 mm . column fitting in 12 mm x 150 mm anchor bolt in foundation. including installation machineries, scaffoldings, electricity, other site utilities in client scope. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. type 2 (for seating areas ). item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structure stability certificate will be provided etc complete. 11 providing & fixing of type 01 module ( with back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made in combination of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 12 providing & fixing of type 02 module ( without back rest) frp seating with pvc wooden panel bench should be made in combination of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life . item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 13 providing & fixing of type 01 module ( with back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 14 providing & fixing of type 02 module ( without back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 15 dustbin frp dustbin should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant) all weather proof & maintenance free with long design life. the product should be 700 x 500 frp planter with basic design and 40 x 20mm sq. pipe to support the section of dustbin. it should be selfcolored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 to 4 mm average with sizes 2000x600 mm. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 16 providing & placing at position type1 of 700mm x 305mm frp plantershould be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should be 700 x 305 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage shall be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 17 providing & placing at position type2 of 610 mm x 254 mm frp planterfrp planter should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should 610 x 254 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 18 providing & placing at position type3 of 510 x 200 frp planter frp planter should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should 510 x 200 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 19 tree grating:- providing & fixing of frp tree grating of size 1100 x 1100 x 25 mm frp material with various design options. made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), the product should be an all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. as per design & drawings with all fittings, fixtures etc. complete. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site.. 20 custom design, supply & installation /surfacing of epdm 6 mm & 19 mm rubber crumbs at site etc complete 21 providing & fixing of tumble twin with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 22 providing & fixing of animal mgr with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 23 providing & fixing of deluxe junior see saw with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 24 providing & fixing double post swing with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site etc complete 25 providing & fixing duck rider with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 26 providing & fixing fun walker single with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 27 providing & fixing step trainer with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 28 providing & fixing chest press double with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 29 providing & fixing shoulder press double with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 30 providing & fixing tai chi cum standing twister with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 31 providing & fixing leg press cum parallel bar with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 32 providing & fixing leg press cum seating twister with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 33 providing & fixing of cobble stone of basalt 100 mm x 100 mm & 40 to 50mm thick etc complete 34 providing, fixing & installation of 18mm thick grc ( glass reinforcedconcrete ) of high quality iso grade upto 2.4 mtr height with 18mm grc chopped strands includingpure white cement , silica sand for finishingwith coating of sbr liquid or equivalent chemical for bonding work with all fittings, fixtures hardwares, wax polishing, caster, fitter, labour charges, scaffolding etc. complete as per design, drawings & manufacturer’s specification also as per instructions from engineer in charge etc. complete. sbr liquid will be used for bonding of various materials of the structure which also helps in waterproofing and adhesion giving it a long life durability specially multi dies will be made using cnc machine giving it a high precession for the design of the structure. material is made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant). its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life including structural stability certificationetc complete. 35 providing, fixing & installation of 4 mm thick frp ( fiber reinforced polymer) material high quality iso grade. frp material placed above grc of high quality iso grade material as per design, drawings & as per manufacturer’s specification & instructions from engineer in chargeincluding all hardener, fittings, fixtures, welder, patch work,labours charges, scaffolding etc. complete . the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life including structural stability certification etc complete. 36 providing & applying weather finish coating & lackering of 100microns to all surfaces of grc & frp with all rubbing, finishingwith all equipments, labours, scaffolding all as per design, specification & instructions from engineer in charge etc. complete 37 waterproofing cum insulation composite system:-cleaning the surface to make it dust free andsludge free, removing any extended portions by grinding and if required using suitable equipment’s and should be totally dry & have proper slope for free flow of water preparing the surface by spray applying a coat of bitumen primer @0.25-0.35kg/square metre over the entire dust free surface. providing and applying single layer of ultraplast b app- 4mm (atactic polypropylene polymer) modified water proofing membrane reinforced with non-woven polyester matt 160+20 g/m2 having polymer film as a top surface. minimum tensile strength in longitudinal and transverse direction as 750n +150 / 600n +120/5cm (astm d 5147). minimum nail shank tear resistance in longitudinal and transverse direction as 300/300n + 100 n (astm d 4073) elongation in longitudinal and transverse direction 40+8% / 45+9%. softening point of membrane not less than 150 + 5 degree celsius consisting of a coat of technonicol bitumen primer no 01 primer @ 0.25- 0.35 ltr./sq.mtr with a relative viscosity of 15-40 s,. over the primer coat, the layer of membrane shall be laid using butane / lpg torch and sealing all joints with minimum 75 mm side laps & 100 mm end laps to form a monolithic system. the laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane etc complete. 38 providing and laying leed certified carbon prof 300 extruded polystyrene 50mm thick having thermal conductivity of 0.028 w/mk (astm c 177) with compressive strength of > 300 kpa (astm d 1621 en 826) and density of 30-35 kg/m3. long term water immersion astm c 272 (en12087) < 0.7% over the waterproofing membrane having shiplap arrangement. work shall be done through the authorized applicator of the manufacturer of the insulation boardetc complete. 39 prviding & fixing glassreinforced concrete (grc)25mm jali as per deign & details etc completed. 40 providing and fixing heavy gauge galvinsed iron 50”fan with autoopening 10shutters, drop hamper exhaust fan systems with 6 no.ss blades with low noise , cfm:-25890, auto opening shutters damper type 415v,50hz, 1.5hp motor, 3hp with fitting etc complete.cellulose cooling pad 1200mmx600mmx100mmt one pad contain area of 1 0 sqft, leading kit with pipeline upto frame,- bypass, filter flush system etc.6”aluminum frame for the above coolingpads with top water distribution and bottom gutter, aluminum 41 providing & fixing air circulation fans 7 blades ss aluminum powder coated of model gtacf-40-70, size of d320mmxh400, 50hz , 1400 rpm, 220v, 120w, single phase, 70 ft airflow etccomplete. 42 automatictemp humidity controller- providing & fixing microprocessor based temp & humidity controller excluding moisture sensors, electrical control panel for fan,cooling pad, pump, mcb, contractor, olr, auto manual switching on/of fswitches ip55 cabinet, electrical cable 1 .5sqmm 4core for fans and pads,sensor cable 4core 0.5square mm etc complete. 43 providing & fixing controller - plc & hmi based control, drip valves control -2 nos,dosing valves control- 3nos ( a-b,c-acid), filling pump, system pump, air pump control, mixing valve control, phase missing prevention, over current prevention control, operation modes: auto -manual-bypass. 44 providing & fixing dosing unit includes dosing channels - 3nos @400lph with flow indicatiors & regulators, dosing valves - 3 nos (a-b,c-acid ), system pump - 30klph@35m head- ss 316 grade, dosing line filters-3nos 45 providing & fixing flow sensor of 3” as per design & drawing etc complete. 46 providing & fixing regenerative air blower-385cfm for 2 stocks mixing as per design & drawing etc complete. 47 providing & fixing solenoid valvesof 2” as per design & drawing etc complete. 48 providing & fixing exhaust fans -1.5hp 3phase- 16 nos4 controls ( each control 4 fans) pad pump - 3hp, 3phase- 1no fogging pump-5hp- 1no acf- 0.5hp- 1phase- 32nos - 1 control (3 phase load distribution) temperature sensor - 1no etc complete. 49 providing & fixing pressure release valves of 2” as per design & drawing etc complete. 50 providing & fixing total galvinsed iron structure of column pipes, profile, zig-zag spring, locking, perlins, tie bar, cross, gutter purlin, hockey , hockey memeber, hockey runner, nagarpatta, galvinsed gutter sheet, l, f brcackets, clamps, bolts , nuts, self drilling screw, spring, sliding pulley, netring, curtain clamps, door cup, handle, fiber door, hole pass. above all incudes, complete structure- erection, fixing etc complete. 51 poviding & fixingpoly film, 50% shade net, 30% side net with 6.5m center height,d rain out, israel make ginegar diffuse 200micron. above all incudes, making foundation, completestructure- erection, fixing etc complete. 52 providing & fixing high-tech irrigation system including inline drip lateral, inside main and sub main pvc pipes, fogger system, sand filter, disc-filter, ventury system with instillation & testing. 3024 sqm etc complete. 53 providing &fixingweed control mat 3000 sq mtr 120 gsm as per design & drawing etc completed. 54 providing &fixingplastic trough20:50:20500 micron 6000 running mtr etc complete. 55 providing & supplying low electrical conductivity coco-peat as instructed etc complete. 56 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 300mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 57 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 600mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 58 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 900mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 59 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 1200mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frameetc complete 60 supply, installation, testing, and commissioning of the electrical trench, with dimensions of 1300mm length, 1300mm width, and 1300mm depth, which includes a cover at every 15-meter interval, and also includes all necessary civil work to complete the electrical trenchetc complete 61 providing and fixing of ‘seamless gloss’ tiles of himalyan acoustics / baux / baswa or equivalent20mm thick with square edge made of gloss base panel (non-magnisite) with wood fibre 1mm width cement composites covered with acoustically transparent absorptive microfibers on the front side pasted on site with sprayable glue and colour as per the choice of the architect/ person in charge with seamless finish. has excellent noise absorption of 0.85 nrc as per iso: 354-1985 and astm 423-90 a, stc of 47 as per astm e90/413 for 25mm, density 400 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60o celcius(140o farenhite) for 15 days= no deterioration. conforms to en 131682001 and are rohs complaint and anti-bacterial test as per jis-z2801-2010.to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized xt-red-selected">steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results( ceiling absorption nrc 0.85) etccomplete. 62 providing fibrette doodle 20 ceiling tiles of himalyan acoustics / baux / baswa or equivalent made of wood fibre cement composites with an option of colours as per the choice of the architect/ person in charge of size 1200 x 600 mm highly recommend for walls / ceilings. has excellent noise absorption of 1 nrc as per iso: 354-1985 and astm 423-90 a, density 400 kg/ m3, meets stringent fire ratings astmd-876 and fire class -1 and class p-not easily ignitable as per bs-476-part 5,6,7, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60° celsius (140° fahrenheit) for 15 days= no deterioration. tested as per en 131682001 and are rohs complaint. to be installed on g.i studs 600x600mm centre to centre2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized xt-red-selected">steel with 120gsm zinc coating specially designed for acoustic vibration management and long life witha backing of himalyan acoustics 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results(ceiling absorption nrc 1 ) etc complete 63 providing and fixing of ‘seamless gloss’ tilesof himalyan acoustics / baux / baswa or equivalent wth 20 mm thick with square edge made of gloss base panel (non-magnisite) with wood fibre 1mm width cement composites covered with acoustically transparent absorptive microfibers on the front side pasted on site with sprayable glue and colour as per the choice of the architect/ person in charge with seamless finish. has excellent noise absorption of 0.85 nrc as per iso: 354-1985 and astm 423-90 a, stc of 47 as per astm e90/413 for 25mm, density 400 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60o celcius(140o farenhite) for 15 days= no deterioration. conforms to en 131682001 and are rohs complaint and anti-bacterial test as per jis-z2801-2010.to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized xt-red-selected">steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results (ceiling absorption nrc 0.9 )etc complete. 64 providing wooden micro perforated fr grades 600x600 / 600x1200 16mm made of mdf backed with acouscal fleece providing sound absorpon of abs. coeff. 0.92 @125hz as per (equivalent to iso: 354-1985 & astm 423-90).to be installed with hidden aluminium profile conforms to aluminium alloy 6063-t6.temper as per bs:1474-1987. the density per panel is 750-800 kg/m3. these panel are made from acouscal fibreboard with linear perforaons for excellent uniformity. the perpendicular holes areavailable on the panel. wooden micro perforated can be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized xt-red-selected">steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm acousc wool tested as per fire retardant astmd 635- 1991/insulation and is 15061-2002 for excellent result wall treatment upto 8ft height etc completeof himalyan acoustics / baux / baswa or equivalent etc complete. 65 providing and fixing ‘aphony cortex’ splendortiles made of wood fibre 1mm widthcement composites 25 mm thick (non magnesite bonded) and covered with acoustically transparent woven fabric on the front side, with an option of colours as per the choice of the architect/ person in charge of size 1200x600/ 600x600 mm.providing sound absorption of 1 nrc as per iso:354-1985 and astm 423-90 a, stc of 49 as per astm e90/413 meets the stringent fire ratings astmd- 876 and bs:476, weather resistant as per is 3308 thermal conditivity result 45 w/m2/kas per is:3346-1980. conforms to en 131682001.to be installed with pvc h profile on g.i studs600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized xt-red-selected">steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of himalyan acoustics. 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 thermal conductivity test , w/mk , as per astm c 518 test result ( sc-6490) -0.03312for excellent results.wall absorption nrc 1 etc complete. 66 providing fibrette doodle 25mm walls himalyan acoustics / baux / baswatiles made of wood fibre cement composites with an option of colours as per the choice of the architect/ person in charge of size 1200 x 600 mm highly recommend for walls / ceilings. has excellent noise absorption of 1 nrc as per iso: 354-1985 and astm 423-90 a, density 400 kg/ m3, meets stringent fire ratings astmd-876 and fire class -1 and class p-not easily ignitable as per bs-476-part 5,6,7, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60° celsius (140° fahrenheit) for 15 days= no deterioration. tested as per en 131682001 and are rohs complaint. to be installed on g.i studs 600x600mm centre to centre2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized xt-red-selected">steel with 120gsm zinc coating specially designed for acoustic vibration management and long life witha backing of himalyan acoustics 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results wall absorption nrc 1 etc complete. 67 providing and fixing ‘aphony fibril’ tiles20 mm with himalyan acoustics / baux / baswa or equivalenttaper edge made of compressed wood fibre made with (non-magnesite bonded) inorganic compound with mat blackcolour of size 600x1200/600x600mm. has excellent noise absorption of 0.70 nrc as per iso: 354-1985 and astm 423-90 a, stc of 48 as per astm 90/413 density 650-750 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , tested as per astm c 367-99 to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized xt-red-selected">steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of himalyan acoustics. 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002for excellent results.make etc complete. 68 providingfloor carpet ofhimalyan acoustics / baux / baswa or equivalent with specification : weight :875 dynamic loading ( bs 4052)nominal thickness ( mm): 4.00color fastness tested as per.is 5641wash ( is 11969)light ( is 0686)flammability test ( is 5641) etc complete. 69 providing and fixing of acoustic door ofhimalyan acoustics / topakustik / baswa or equivalent of 56 mm having an stc rating upto 59.6 @ 100 hz as per iso:140/astm90/413. the door will be filled with high acoustic materials of 2 layers of 8 mm water proof acoustic ply with dampner sheet, 2 layers of 10mm thick absorb wool 300 gsm, sound dampner 12mm 1218x1218 mm made of 10 mm compressed wood cement composites 1250kg/m3 and 2mm dampner sheet 37 stc as per iso 140 (part-iii) - 1995. final finish with teak ply 4mm thick interior and exterior side. door frame will be made of teak wood teak wood/ engineered wood. frame on all four sides or three sides frame and drop seal below will be provided along with the door. high load bearing hinges will be provided along. fr tested as per is:3614 (pt. ii) & bs: 476-(pt.20 & 22). 70 providing and fixing of teak wooden flooring of himalyan acoustics / baux / baswa or equivalent of20mm thickness with polish. teak wooden flooring with tongue and groove system with size 510x90x20mm. termite treated seasoned. to be installed on ply board 16mm.floor polish charges included etc complete. 71 supply & installation of auditorium tip-up chairs:seat to be mounted on center pedestal 75mm x 100mm mounted on ms plate 200mm x 200mm x 6mm thickness. seat & contoured back made in cold injection moulded pu foam of density of 60kg/m3 and 46kg/m3 respectively over metal structure.19 0colored cushion (fabric colour to clients choice) with removable seat cover.seat and backrest frames are made out of metal frame structure black powder coated.upholstered back to with multi angle adjustable mechanism upto 30 degrees inclination.counterweight silent/noiseless tip up seat mechanism, seat shall be able to be removed easily for cleaning and maintenance without the need of any tools. solid armrests laminate finished (wooden appearance) seat number in oval acrylic and row number in metal plate, with provision for wiring to put led illumination. strength & durability of seat to comply to en12727: 2016 for level 4 load test.fire resistance to meet bs5852 & bs 7176warranty 5 years. price inclusive of transportation with all leads and lifts etc, complete. 72 statue- balasaheb thakreproviding statue of 15 ft height in 1st quality fiber material with metal armature (jindal). with internal structure pipe 100mm dia pipe welded together with support pipe in between and arm also with the same pipe of size 1mtr-0.5 mtr the overall height would be 3.5mt from ground. item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. material made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. structural stability certificate will be given. 73 sculpture-1 man sitting providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 74 sculpture 2 man with hammer sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 75 sculpture 3 women standing- sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care 76 sculpture 4 buffalo- sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 77 sculpture-5:- man with calf and calf sculpture -providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 78 sculpture-6:- man standing sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 79 selfie point i love haldi providing & fixing of 2.8m x 2.8 m with height of 2.8m. frp kiosk. made of frp material with dark wood finish. frp dustbin included in the kiosk. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild xt-red-selected">steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5viscosity aliphatic paint. with long standing life. item is including placing, installation with all fittings, fixture, hardwares , all as per design, drawings & as per instructions from engineer in charge etc. complete on site.
Tender for gem bids for clearing jungle including uprooting of rank vegetation grass brush wood trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. "supplying chemical emulsion in sealed containers including delivery as specified. chlorpyriphos or lindane emulsifiable concentrate of 20 percent" "diluting and injecting chemical emulsion for post constructional anti termite treatment excluding the cost of chemical emulsion along external wall where the apron is not provided using chemical emulsion at the rate 7.5 litres or sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall and rodding etc. complete isto with chlorpyriphos or lindane e.c. 20 percent with 1 percent concentration" "earth work in excavation by mechanical means hydraulic excavator or manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m all kinds of soil." filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m supplying and filling in plinth with sand under floors including watering ramming consolidating and dressing complete. "providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1 isto 3 isto 6 1 cement 3 coarse sand zone iii 6 graded stone aggregate 20 mm nominal size " "providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering shuttering finishing and reinforcement all work up to plinth level isto 1 isto 1.5 isto 3 1 cement 1.5 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size " "reinforced cement concrete work in walls any thickness including attached pilasters buttresses plinth roof and string courses fillets columns pillars piers abutments posts and struts etc. above plinth level up to floor five level excluding cost of centering shuttering finishing and reinforcement 1 isto 1.5 isto 3 1 cement 1.5 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size " brick work with common burnt clay f.p.s. non modular bricks of class designation 7.5 in foundation and plinth in cement mortar 1 isto 6 1 cement 6 coarse sand brick work with common burnt clay f.p.s. non modular bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1 isto 6 1 cement 6 coarse sand "half brick masonry with common burnt clay f .p .s. non modular bricks of class designation 7.5 in superstructure above plinth level up to floor v level. cement mortar 1 isto 4 1 cement 4 coarse sand " "centering and shuttering including strutting propping etc. and removal of form for foundations footings bases of columns etc. for mass concrete" "centering and shuttering including strutting propping etc. and removal of form for suspended floors roofs landings lintals beams balconies and access platform" "xt-red-selected">steel reinforcement for r.c.c. work including straightening cutting bending placing in position and binding all complete upto plinth level thermo mechanically treated bars of grade fe 500d or more make sail or tata or jindal " "15 mm cement plaster on the rough side of single or half brick wall of mix isto 1 isto 6 1 cement isto 6 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " "12 mm cement plaster of mix 1 isto 6 1 cement isto 6 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " "6 mm cement plaster of mix 1 isto 3 1 cement 3 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " neat cement punning. "finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade new work two or more coats applied at the rate 1.43 ltr or 10 sqm over and including priming coat of exterior primer applied at the rate 2.20 kg or 10 sqm make dulux or burger or asian paints or as per direction of eic" white washing with lime to give an even shade new work three or more coats mix with fevicol ddl and robin blue or as per direction of eic "painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. preferable make dulux or burger or asian paints or as per direction of eic make dulux or burger or asian paints or as per direction of eic" making plinth protection 50mm thick of cement concrete 1 isto 3 isto 6 1 cement 3 coarse sand zone iii 6 graded stone aggregate 20 mm nominal size over 75mm thick bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling and dressing and finishing the top smooth "providing and fixing angle iron frames for doors windows and ventilators of mild xt-red-selected">steel angle sections of size 35x35x5 mm joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t iron frame or to the wall with dash fastener including fixing of necessary butt hinges and screws and applying a priming coat of approved xt-red-selected">steel primer all complete as per the direction of engineer in charge. make sail or tata or jindal " "providing and fixing isi marked flush door shutters conforming to is isto 2202 part i decorative type core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including isi marked stainless xt-red-selected">steel butt hinges with necessary screws" "structural xt-red-selected">steel work in single section fixed with or without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved xt-red-selected">steel primer all complete. make sail or tata or jindal " 25 mm thick pvc flush door shutters made out of a one piece multi chamber extruded pvc section of the size of 762 mm into 25 mm or less as per requirement with an average wall thickness of 1 mm plus or minus 0.3 mm . pvc foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. m.s. tube having dimensions 19 mm into 19 mm and 1.0 mm plus or minus 0.1 mm is inserted along the hinge side of the door. core of the door shutter should be filled with high density polyurethane foam. the top and bottom edges of the shutter are covered with an end cap of the size 25 mm into 11 mm. door shutter shall be reinforced with special polymeric reinforcements as per manufacturer specification and direction of engineer in charge to take up necessary hardware and fixtures. stickers indicating the locations of hardware will be pasted at appropriate places "providing and fixing isi marked oxidised m.s. sliding door bolts with nuts and scrows etc. complete .as per the direction of directions of engineer in charge.300x16 mm " "providing and fixing ist quality ceramic glazed wall tiles conforming to is 15622 thickness to be specified by the manufacturer of approved make somany or kajaria or nitco in all colours shades except burgundy bottle green black of any size as approved by engineer in charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1 isto 3 1 cement 3 coarse sand and jointing with grey cement slurry at the rate 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. make isto somany or kajaria or nitco or asian or as per direction of eic" "providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer with water absorption less than 0.08percent and conforming to is 15622 of approved make in all colours and shades laid on 20mm thick cement mortar 1 isto 4 1 cement 4 coarse sand jointing with grey cement slurry at the rate 3.3 kg or sqm including grouting the joints with white cement and matching pigments etc. complete. size of tile 600x600 mm make somany or kajaria or nitco or asian or as per direction of eic" "providing and fixing water closet squatting pan indian type w.c.pan with 100 mm sand cast iron p or s trap 10 litre low level white p.v.c. flushing cistern including flush pipe with manually controlled device handle lever conforming to is 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests preferable make hindware or parrywair or hindustan or cera or direction of eic" "providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and c.p. brass spreaders with brass unions and g.i clamps complete including painting of fittings and brackets cutting and making good the walls and floors wherever required one urinal basin with 5 litre white p.v.c. automatic flushing cistern preferable make hindware or parrywair or hindustan or cera or direction of eic" "providing and fixing wash basin with c.i. brackets 15 mm c.p. brass pillar taps 32 mm c.p. brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require isto white vitreous china wash basin size 630x450 mm with a single 15 mm c.p. brass pillar tap" "providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete. semi rigid pipe 32 mm dia" providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with c.p . brass screws and washers complete. "providing and fixing brass bib cock of approved quality 15 mm nominal bore" "providing and fixing brass stop cock of approved quality 15 mm nominal bore" providing and fixing circular or hexagonal cast iron or m.s. sheet box for ceiling fan clamp of internal dia 140 mm 73 mm height top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron or m.s. sheet box by means of 3.3 mm dia round headed screws one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. providing and fixing isi marked oxidised m. s handles conforming to is 4992 with necessary screws etc. complete 125 mm providing and fixing bright finished brass hanging type floor door stopper with necessary screws etc. complete. providing and fixing is 12817 marked stainless xt-red-selected">steel butt hinges heavy weight with stainless xt-red-selected">steel screws etc. complete 100x60x2.50 mm "providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work a. 15 mm dia nominal bore preferable make tata or jindal or as per direction of eic" "providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work b. 20 mm dia nominal bore preferable make tata or jindal or as per direction of eic" providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work d. 50 mm dia nominal bore preferable make tata or jindal or as per direction of eic "providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is 13592 type a including jointing with seal ring conforming to is 5382 leaving 10 mm gap for thermal expansion single socketed pipes. 110 mm diameter" "providing and fixing gun metal gate valve with c.i. wheel of approved quality screwed end isto 20 mm nominal bore" "providing and fixing gun metal gate valve with c.i. wheel of approved quality screwed end isto 50 mm nominal bore" providing and placing on terrace at all floor levels polyethylene water storage tank is isto 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank. providing and fixing 100 mm sand cast iron grating for gully trap constructing brick masonry chamber for underground c.i. inspection chamber and bends with bricks in cement mortar 1 isto 4 1 cement 4 coarse sand c.i. cover with frame light duty 455x610 mm internal dimensions total weight of cover with frame to be not less than 38 kg weight of cover 23 kg and weight of frame 15 kg r.c.c. top slab with 1 isto 1.5 isto 3 mix 1 cement 1.5 fine sand isto 3 graded stone aggregate 20 mm nominal size foundation concrete 1 isto 5 isto 10 1 cement 5 fine sand 10 graded stone aggregate 40 mm nominal size inside plastering 12 mm thick with cement mortar 1 isto 3 1 cement isto 3 coarse sand finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets isto with common burnt clay f.p.s. non modular bricks of class designation 7.5 "constructing masonry chamber 30x30x50 cm inside in brick work in cement mortar 1 isto 4 1 cement isto 4 coarse sand for stop cock with c. i. surface box 100x100 x75 mm inside with hinged cover fixed in cement concrete slab 1 isto 2 isto 4 mix 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20 mm nominal size i or c necessary excavation foundation concrete 1 isto 5 isto 10 1 cement isto 5 fine sand isto 10 graded stone aggregate 40mm nominal size and inside plastering with cement mortar 1 isto 3 1 cement isto 3 coarse sand 12mm thick finished with a floating coat of neat cement complete as per standard design isto with common burnt clay f.p.s. non modular bricks of class designation 7.5" providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level isto 1 isto 1.5 isto 3 1 cement isto 1 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter 1.8 m long complete as per standard design. with common burnt clay f.p.s. non modular bricks of class designation 7.5 "cement concrete flooring 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate finished with a floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate" "providing and fixing precoated galvanised xt-red-selected">steel sheet roofing accessories 0.50 mm plus 0.05 percent total coated thickness zinc coating 120 grams per sqm as per is 277 in 240 mpa xt-red-selected">steel grade 5 to 7 microns epoxy primer on both side of the sheet and polyester top coat 15 to 18 microns using self drilling or self tapping screws complete ridges plain 500 to 600mm " "providing and fixing precoated galvanised iron profile sheets size shape and pitch of corrugation as approved by engineer in charge 0.50 mm plus 0.05 percent total coated thickness with zinc coating 120 grams per sqm as per is 277 in 240 mpa xt-red-selected">steel grade 5 to 7 microns epoxy primer on both side of the sheet and polyester top coat 15 to 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin charge. the sheet shall be fixed using self drilling or self tapping screws of size 5.5 x 55 mm with epdm seal complete upto any pitch in horizontal or vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required." providing and fixing of glass panes with putty and glazing clips in xt-red-selected">steel doors and windows all complete with 4mm thick glass panes etc. complete. supply of led tube light fittings .make c.g. or philips fixing of led tube light fittings including supply of all hardwares as required. led fitting will be supplied by contractor. make c.g. or philips supply of 48 sweep ceiling fan complete with down rod.clamp canopy etc. fixing of 48 sweep ceiling fan complete with down rod.clamp canopy etc.fan hardwares required for fixing for i.e. nut bolts clamp screws etc wiil be supplied by contractor. supply and fixing of stepped type electronic fan regulator on existing switch board. wiring for light point fan point exhaust fan point with 1.5 sqmm frls pvc insulated copper conductor single core cable in consield with modular switch modular plate suitable gi box and earthing the point with 1.5 sqmm frls pvc insulated copper conductor cable as required. supply of frls pvc insulated copper conducter single core cable of size 6 sqmm. make havells or kei or polycab or national wiring for circuit or submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in consield or recessed medium class pvc conduit in concield as required 2 x 6 sqmm plus 1 x 6 sqmm earth wire. all the three colours should be red blue and green supply and fixing of utility db p or s 20a dp metal plug and socket distribution board grey make anchor or havells supply and installation of three phase industrial box with 32 amp 4 pole mcb and 5 pin top plug. make neptune or reputed make supply of frls pvc insulated copper conducter single core cable of size 10 sqmm. make havells or kei or polycab or national wiring for circuit or submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface or recessed medium class pvc conduit in concield as required 4 x 10 sqmm + 1 x 10 sqmm earth wire.all the five colours should be red blue yellow black and green preparation of earth pit with supply of all materials including 3m long 3.64mm thick perforted gi tube with salt and charcol in alternate layer and brick chamber at the top with chequered plate 6mm thick as per is 3043 with latest. supply and laying 25mm x 5 mm gi strip at 0.5 meter below ground or wall including connection with electrode with db. supply of all hardware are in scope of contractor supply ans fixing of surface mounting vertical type 415 volts tpn mcb distribution board of sheet xt-red-selected">steel dust proctected duly power coated painted inclusive 200 amp tinned copper bus bar common neutral link earth bar din bar for mounting mcb with provision of 100 amp tpn mccb as incomer interconnection between incomer mccb and busbar. supply and fixing of 5 to 32 amp rating 240 or 415 volt mcb suitable as per load. supply and fixing of four pole 100 amp rating 415 volt 16 ka mccb . laying of 1.1kv grade pvc al.cable of size 2 or 3 or 3.5 or 4c 2.5 or 6 or 10 or 16 or 25 or 35 sq.mm in underground trench of 760mm deepx760mm wide in single tier formation including trench excavation and back filling with bricks 15brick or m and sand protection route marker. road or concreete or bolder cutting and finishing the road to its original shape are in the scope of the contractor. supply and fixing of street light on wall including supply of all necessaryu hardware for fixing of fitting on wall. supply and fixing of bulk head fitting on wall including supply of all necessaryu hardware for fixing of fitting on wall. supply installation and commissioning of exhaust fan of size 300 mm dia. this includes cutting of wall and finishing and supply of hardware like nut bolts etc. make crompton
Tender for tender for kareli - nurulla road to askari market road block c and block d housing scheme and nurulla road from mahavir chauraha to karamat ki chowki near sasur khedari river and also till the connecting road - clearing grass and removal of rubbish upto a distance of 30 m outside the periphery of the area as per technical specification clause 201. 3 dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, xt-red-selected">steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 60 metres as per instructions of e-i-c. (by mechanical means). 4 i) cement concrete 5 ii) reinforced cement concrete/ r.b. 6 dismantling of flexible pavements and disposal of dismantled material up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per technical specification clause 202. bituminous / granular courses (by mechanical means) 7 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 8 removing all type of hume pipes and stacking within a lead of 1000 metres including t&p, earthwork and dismantling of masonry works. 9 (i) up to 600 mm dia 10 removal of telephone / electric poles / street light / lamp post including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately 11 disposal of moorum/building rubbish malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of engineer-in-charge. note- item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 12 dewatering using 10hp to 70hp diesel engine pump set including hire charges, cost of diesel, engine oil, pump operator, labor charges, conveyance of pump set and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (hire charges for diesel pump set for 10 hp) 13 [b] bill no. 2 - earthworks 14 excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and leading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location within all lifts and lead upto 1000m 15 removal of unserviceable soil including excavation loading and disposal but excluding replacement by suitable soil which shall be paid separately as per clause 305 16 i) lead upto 1000 m 17 ii) lead upto 8000 m 18 earth work in excavation of foundation of structures as per drawing and technical specification, including setting out construction of shoring and bracing, removal of stumps and other deleterious matter dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for road work. 19 mechanical means (depth upto 1.5 m) 20 i) excavation 21 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 22 [c] bill no. 3 - development of carriageway 23 stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with irc-sp-72-2015 , irc-37-2012 & 2018 and irc sp 89 (part ii) 2018. cementitious additive @ rate of minimum 5 - 7% and ccs/cs additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. the additive spreader shall have variable working width sufficient to cover whole pavement lane. the in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. the resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per irc 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. the entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. the tandem roller be followed by pneumatic tyre roller. the minimum unconfined compressive strength (ucs) of stabilized sub base/ base should be 4.5 to 7 mpa after 7 / 28 days of curing as per irc-sp- 72-2015 , irc-37-2012 & 2018 . also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the gradation mixes and materials should be as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the train of equipments to be used are binder spreader- water tanker- additive truck- recycler- padfoot roller (20 tonne) + single drum compactor- grader- tandom roller- pneumatic tyreroller (20 tonne) 24 sami layerproviding and laying stress absorbing membrane interlayer (sami)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of claues 703-3, laid over a tack coat of paving grade bitumen 80- 100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement surface. 25 providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (tack coat on bituminous surfaces ) 26 providing and laying 40mmthickbitumencarpete(b.c.) with 100-120 tph hot mix plant producing and average output of 75 tonege par hour using crushed aggregates of specified grading premixed with bitumen binder(vg-30) @ 5.40% of mix as per most specification clause. etc all comp of work. 27 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from aggregat aggregate natural sources, portland pozzolana/ordinary portland/portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall. be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 28 m.s. (tor xt-red-selected">steel or plain) in plain work such as rcc or rb work including binding for proper shape and including supply of xt-red-selected">steel and its wastage bend, hooks and authorized overlapping shall be measured and including cost of binding wire. excluding gst (sor-504). 29 [d] bill no. 4 - pedestrian infrastructure (footpath) 30 sand filling in foundation trenches as per drawing & technical specification and as per direction of engineer-in-charge. (including beneath all paver blocks, cobble areas for levelling purpose, etc.) 31 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. (pcc below all paving area, kerb channel, road edge kerb, table top, property edge beam) 32 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 33 i) for grading-i material 34 plain/reinforced cement concrete in open foundation complete as per drawing and technical specifications, pcc grade m30using batching plant transit mixer & manual placing(80 mm thickness) r & manual placingand giving broom finish. (pcc with broom finish thickness 80 mm) 35 providing and laying 75mm thick m-30 grade batch mix cement concrete and applying stamping finish to the top surface of freshly laid plain/ reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the engineer-in-charge. the process shall include the following:-the concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. the approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. the approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. these stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the hole surface to be stamped is completed within the time while concrete is in plastic stage of setting.after stamping, the curing shall be done as per manufactures specifications. after initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per theequirement. the surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.the construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (pu) polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (cost of concrete for flooring is not included in this item which shall be paid separately.) 36 80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 37 supply and fixing of tactile indicators made from ss-304 grade stainless xt-red-selected">steel. warning tactile indicator shall be installed on the walking surface in a raised grid pattern of dots or stud. minimum 36 studs to be placed in 300x300 mm area. dimensions - 35mm outer dia x25mm inner dia, stem dia 8mmx12mm, weight - 28grm.all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property, all complete as per direction of engineer-in-charge. 38 supply & fixing of tactile indicators made from ss-304 grade stainless xt-red-selected">steel. directorial tactile indicator shall be installed on walking surface, consisting of a series of raised bar/strip. min 4 bars/strip to be placed in direction perpendicular to distance of travel in 300x300 mm area. dimensions-280mm l x 35mm w x 4.5mm, stem dia 8mmx12mm, weight - 250grm all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property., all complete as per direction of engineer-in-charge. 39 providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to is : 15622 of approved make in all colors and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer-in-charge 40 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (dsr-11.20) 41 providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of engineer-in-charge. (saucer drain along the road edge, curved kerbs at property entry/exit, curved kerbs at side roads) 42 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 43 cc grade m20 using batching plant transit mixer & manual placing all complete as per direction of e-i-c. 44 [e] bill no. 5 -parking 45 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 46 i) for grading-i material 47 supplying and filling in plinth with sand under floors/in trenches, including watering, ramming, consolidating and dressing all complete with material (from source to site), labor and t&p etc. required for proper completion of the work. (including royalty). 48 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days and giving broom finish. (pcc) 49 providing and laying factory made chamfered edge cement concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using pu mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of engineer-in-charge.80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 50 [f] bill no. 6 -cycle track 51 nil 52 [g] bill no. 7 - traffic signs, markings and other road appurtenances 53 providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow ms tube posts/horizontal members/bracings covered with 1.63mm thick ms sheet. the sheet shall be fixed with 30x5mm ms flat by suitable welding/riveting. the panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. ms channel islc 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long ms angle 40x40x6mm bracing. suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. the work shall be executed as per drawing/direction of engineer-in-charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the engineer-in-charge. the barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of engineer[1]in-charge.(note :- one time payment shall be made for providing barricading from start of work till completion of work i/c shifting. the barricading provided shall remain to be the property of the contractor on completion of the work). 54 reflective raised pavement markers (cat eye/ road stud) supply and fixing of raised pavement marker with made of plastic body of rpm/ road stud shall be moulded from asa (acrylic styrene acrylonitrile) or hips (high-impact polystyrene) or acrylonitrile butadiene styrene (abs) or any other suitable material approved by the engineer. the marker shall support a load of 13,635 kg tested in accordance with astm d4260. the reflective panels shall consist, of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face. lenses shall be moulded of methyl methacrylate conforming to astm d788 of equivalent. the slop or retro-reflecting surface shall preferably ba 5+/.5 degree lo base and the area of each retro -reflecting surface shall not be less than 13.00 $q.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & width shall not exceed 130 mm the base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. the contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the engineer . in addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. in case the markers are, displaced , damaged . get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the engineer , at his own cost. the rate shall include all materials, labor, t&p, transportation, installation and incidentals all complete as per direction of the engineer-in-charge, 55 rpm with shank 56 solar power road marker the solar studs shall be made of aluminum alloy and polycarbonate material which shall be absolutely weather resistant and strong enough to support to load of 13,635 kg tested in accordance with astm d4280. its color may be white, red, yellow, green or blue or combination as directed by the engineer. its water resistance shall meet the requirements of ip 65 in accordance with is: 12063:1987 category 2 for the protection against water ingress. the dimensions of solar studs shall not be less than 100 mm * 100 mm * 10 mm. it shall have super bright leds so as the provide long visibility from a distance of more than 800 m. its flashing rate shall not be less than 1 hz. its should be able to give the prescribed performance in the temperature range of -40 degree c to +55 degree c. its life shall be not less than 3 years. the rate shall include all material, labor, equipments, fabrication, transportation erection, installation and incidentals all complete as per direction of the engineer-in-charge 57 r.cc work (1:1.5:3) (m-20) with cement course sand &20mm the stone grit including all complete cement concrete with cement sand &20mm gauge stone grit with the proportion of (1:1.5:3)including all complete the work (morth ra-12.8 c, case-ii) 58 m.s. or iron work plain or tor for rcc work including cutting, bending, rivetting or welding etc. where necessary. excluding gst (s.i.no-504) 59 painting two coats on new concrete surfaces - painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 60 m.s. or iron work of heavy sizes section such as trusses, built up gates, record racks, roof work, gates etc. including rivetting or welding where necessary. excluding gst (s.i.no-503) 61 painting of m.s. grill with enamul paint etc all complete work. (s.i. 15.15 new item no.) 62 providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 63 providing and fixing of retro- reflectorized cautionary, mandatory and informatory sign as per irc :67 made of high intensity grade sheeting type-ivvide clause 801.3, 2mm thick aluminum sheeting, 1.5 mm thick supported on mild xt-red-selected">steel angle iron post 75mm* 75mm *6mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45cm* 45cm*60 cm, 60 cm below ground level as per the approved drawing. the retroreflective sheeting shall be tested for a certificate of having the sheeting coefficient of retro reflection, daytime, color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoors weathering and its having passed these tests shall be obtained from international/ government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should be also obtained from indian condition within 3 years of launching ofproduct by the manufacturing abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirement from a reputed laboratory in india can be accepted provisionally. in such a situation , the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per irc 67:2012 . legends, letters, numerals, and borders etc. should be as per mort&h specification 801.3.7. proof of the same in form of government reports shall be uploaded while quoting tender. 64 90 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 65 60 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 66 60 cm circular with diffinitation plate size (20cm x 60 cm) 67 80mm x 60mm rectangularwith diffinitation plate size (20cm x 60 cm) 68 60 mm x 45 mm rectangularwith diffinitationplate size (20cm x 60 cm) 69 60cm x 60cm square with diffinitation plate size (20cm x 60 cm) 70 90 cm high octagon 71 direction and place identification signs up to 0.90 sqm size board providing and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/ client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area not exceeding 0.9 sqm. supported on a mild xt-red-selected">steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60cm., below ground level as per approved drawing, complete. 72 direction and place identification signs with size more than 0.90 sqm size boardproviding and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility. liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area exceeding 0.9 sqm. supported on a mild xt-red-selected">steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing, complete. 73 providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised xt-red-selected">steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per irc :67 74 brick masonry work in cement mortar 1:4 (1cement: 4 coarse sand) in foundation complete with cement concrete bricks procured from c&d waste recycling plant baswar excluding pointing and plastering, as per drawing and technical specifications. 75 struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 finerness modulus.sor 2022 si no574 76 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 sand)and as per direction of engineer in charge. 77 finishing walls with ready mixed premium acrylic emulsion paint (company depot tinted) having volatile organic compound (voc)less than 50 gm/liter and uv resistance as per is 15489:2004, alkali, & fungal resistance, dirt resistance exterior paint of required shade with silicon additive(for painting wall, street furniture) new work (two or more coats applied @1.43 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm) 78 supplying and fixing of cast iron antique style bench having weight of sides not less than 72 kg (36 kg each) fitted with fibre rectangle strip (should not be less than 50 mm x 25 mm and 1.6mm thick. length of bench should not be less than 6 ft (end to end of castiron support). 79 [h] bill no. 8 - utility and street light cabling 80 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(pcc below pipe of storm water, sewer, water, inspection chamber for storm water, telecom chamber, power chamber and sewer) 81 providing and laying non pressure np-3 class (medium duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (storm water, sewer) 82 600 mm dia rcc pipes 83 providing of 7- way 40mm multi ducts with solid permanently solidly lubricated silicone in inner layer for ict fiber cables conforming to astm f 2160, astm d 2444 and /or equivalent indian standard. external sheathshall be in orange colorand shall be free from visual defects like blisters, shrink holes,flaking, scratches, groove lines & surface roughness. the color of the 7 nos. plb hdpe ducts shall be green, blue, yellow, brown, violet, grey , red for differentiation. outer sheet thicknessshall be 1.2mm +/-0.2mm. the inner surface of the multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. wall thickness(mm) of each of the ducts excluding rib height shall be 2.9mm +/- 0.3mm. iso requirements- iso 9001, 14001, 18001, complete as per specifications and directions of engineer-in-charge. (7 way multi utility duct for ofc) 84 supply of hdpe pipe of size 110mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.110mm dia hdpe pipe pn-6 class pe-100 85 supply of hdpe pipe of size 63mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.63mm dia hdpe pipe pn-6 class pe-100 86 rcc grade m20 using batching plant transit mixer & manual placing ( side wall, bottom slab for all inspection chamber i.e. storm water, telecom, power, sewer, water) 87 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class b125 having minimum load capacity 125 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. 88 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class d400 having minimum load capacity 400 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. (storm water) 89 supply and fixing gully grates red 048 grh – 300* 750mm d.i. gully grate & frame in d400 load class , as per bs en 124 black bitumen paint, all complete as per direction of engineer-in-charge. 90 constructing rcc rectangular type manholewith a floating coat of neat cement, foundation concrete 1:6:12mix (1 cement : 6 coarse sand : 12 graded brick bats 40 mm nominal size), and making necessary channel in cement concrete of m-25 grade finished with a floating coat of neat cement, all complete as per standard design and instruction of e-i-c. 91 restoration of water pipeline in case of damage 92 [i] bill no. 9 - horticulture / landscaping works 93 trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 94 supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 95 supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 96 mixing earth and manure in specified proportion or as directed. 97 rough dressing the trenched ground including breaking the clods. 98 fine dressing the ground 99 spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 100 uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 101 providing & laying selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 102 preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of officer-in-charge. 103 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 104 providing and stacking of nauclea cadamba (kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 105 providing and stacking of nyctanthes arbor-tristis (hasingar) of ht. 90-105 cm in earthen pots of size 20 cm as per direction of the officer-in-charge. 106 providing and stacking of terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 107 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 108 providing and stacking of plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 109 providing and stacking of ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 110 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 111 providing and stacking of duranta golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge.. 112 providing and stacking of tradescantia zebrina having in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 113 providing and stacking of wedelia trilobata,full of leaves in 15 cm size ofpoly bags & as per direction of the officer-in-charge. 114 providing and stacking of asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of earthen pot / plastic pot & as per direction of the officer-in-charge.. 115 providing and stacking of ophiopogon jaburan ( variegated ), full of variegated leaves in earthen pot/plastic pot of size 20 cm. as per direction of the officer-in-charge. 116 providing and displaying of croton petra bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 117 providing and fixing ms iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 nos (25 x 6 mm) and 8 nos (25 x 3 mm) vertical ms riveted to 3 nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of priming, complete in all respects. 118 street light works (excluding gst) 119 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 mtr length) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p complete in all respect 120 supply and fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. confirming to ip 66 protection complete in all respect. cat: aaa 121 supply and laying of 16 sq.mm. 4 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 122 supplying and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 123 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 124 making connection of each street light by s/l 1.5 sqmm frlsh copper wire complete as per direction of engineer in charge. 125 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with double arm bracket (1 mtr length each ) on rcc foundationincluding the cost of foundation, foundation bolts, excavation & back filling and required t&p completee in all respect. 126 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 127 supply and fixing for automatic street light cubical control juction box painted with anti-corrosive alkali and acid proof pait consisting of 6 amps mcb (b - curve) complete in all respect 128 supply and fixing of 16 sq.mm plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 129 supply and fixing of 40 amp. capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 130 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. 131 supply/ erection of surface mounted decorative pole 4500 mm long having base plate 300x300x12 mm with the bottom dia 139 mm upto 1 mtr long with the thickness of 3.6 mm and the top dia is 76 mm upto 3.5 mtr. log. decorative pole made out of galvanized iron tube with cast aluminium embellishments. the poles are painted with polyturetnane paint. the pole have service window at the bottom on the pole for housing the mcb and terminal strips and as per attached drawings. 132 s/f of single arm decorative bracket 100 mm long made of cast iron/ aluminium embellishments painted with polyturetnane paint. 133 supply of led decorative drop down light made of aluminium housing fitted with polycarbonate diffuser having 500 mm dia with 70 w. 134 supplyandlayingof aluminiumconductorpvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 135 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 40 a tpn 136 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 16 sq. mm 137 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 138 supply and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 139 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 140 part - b utility shifting (including gst) 141 converstion of lt overhead line by underground lt line 142 lt xlpe insulated cable of size 3.5x400 sqmm. 143 lt xlpe insulated cable of size 3.5x240 sqmm. 144 lt xlpe insulated cable of size 3.5x150 sqmm. 145 lt xlpe insulated cable of size 3.5x70 sqmm. 146 9 mtr long stp 147 hdpe pipe 140mm dia peb0, pn-6 148 hdpe pipe 120 mm dia peb0, pn-6 149 hdpe pipe 75 mm dia p880, pn-6 150 aluminium crimping lugs 400sqmm 151 aluminium crimping lugs 240sqmm 152 aluminium crimping lugs 150sqmm 153 aluminium crimping lugs 70sqmm 154 6 swg g.l. wire for earthing along cables. 155 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x400 sqmm. lt cable 156 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x240 sqmm. lt cable 157 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x150 sqmm. lt cable 158 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x70 sqmm. lt cable 159 main lt panel at sub station- 400 kva (type a-2)lncomer- 1 set of 800 amp. tp mccb with spreader & extended handlemetering on lncomer - 1 set of digital ammeter with ass- 1 set of digatal voltmeter with vss- 1 set of led type phase lndicating light (22.5 mm.)with control mcbsoutgoing- 6 set of 250 amp. tp mccb with spreader & extended handte( 5 nos. + 1 no. for capacitor panel)- 2 set of 100 amp. tp mccb with spreader & extended handle 160 main lt panel at sub statton- 250 kva (type a-2) lncomer- 1 no. 630 amp. tp mdo acb with inbuilt mpr release with i ontoff tnai.ating lightmetering on lncomer - 1 set of digital ammeter with ass- i set oldigital volt-meler wirh vss- 1 set of led type phase indicating light (22.5 mm.j with control mcbs outgoing - 5 set of 250 amp. tp mccb with spreader & exrended handle- 2 set of 100 amp. tp mccb with spreader & extended handle flnstallation oflt distribution boards for lt underground system (type a,b&cj) 161 supply , installation, testing & commissioning of outdoor type feeder pillar panetto be made of 2 mm crca sheet and covers will be j.6mm crca sheet dulypowder coated paint with 300 amps al. busbar. (type-b2)lncomer - 250 amp. tp mccb - 1 no.outgoing - 63 amp. tp mccb - 5 nos.lnstallation of lt distribution boards forlt underground system (type-a, b & c) 162 outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. [type-b3] incomer - 100 amp. tp mccb - 1 no. outgoing - 63 amp. tp mccb - 4 nos.lnstallation of lt distribution boards for lt qnderground system [tvpe-a, b & cl 163 lockable distribution boxes of size 450x400mm with bus bar 100 amp. tpn to feed upto 10 houses (type c) 164 xlpe lt service armoured cable for single phase,2x6 sq. mm.(pvc armoured consumer service cablel 165 xlpe lt service armoured cable for single phase,2x10 sq. mm.(pvc armoured consumer service cablej 166 xlpe lt service armoured cable for three phase,4x10 sq. mm.[pvc armoured consumer service cablel 167 xlpe lt service armoured cable for three phase,4x1.6 sq. mm.(pvc armoured consumer service cablel 168 xlpe lt service armoured cable for three phase,4x25 sq. mm.(pvc armou[ed consumer service cable) 169 pvc pipe 32 mm dia 170 pvc pipe 50 mm dia 171 electronic kwh meter 1px2w with box. for single phase consumer 172 electronic kwh meter 3px4w static meter with box.for three phase consumer 173 carriage , laying of 3.5cx400 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 140 mm dia. 174 carriage, laying of 3.5cx150/240 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 1.20 mm dia. 175 carriage ,laying of 3.5cx70 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 75mm dia. 176 painting of stp incuding paints [2 ltr red oxide and 2 ltr alluminum paint for each pole.l 177 grouting of st pole 178 cartage , erection and dismentling charges 22% of materials cost 179 conversion of 11kv overhead/underground line by 11kv line underground 180 11 kv cable size 3x185 sq.mm xlpe 181 stp 11m-is 410 sp-55 182 g.l pipe 4 dia 183 top channel 100x50x2240 mm 184 hdpe pipe 160 mm dia pe 80, pn-6 185 service clamp o/s 186 clamp for fixing pipe to pole 187 11 kv cable jointing kit size 3x185 sq.mm xlpe o/d 188 11 kv cable jointing kit size 3x185 sq.mm xlpe s/t 189 earthing complete. 190 m.s. nut & bolt with washer 191 bracing angle 65x65x6x2700 mm with clamp 192 stone pad 193 number plates with clamp 194 danger board & clamp with bolts & nuts 195 stay complete 196 g i barbed wire 197 carriage , layrng of 3x185 sq.mm size 11 kv xlpe insulated cable underground in hdpe pipe dia 160 mm. 198 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 199 grouting of st pole 200 grouting of stay set 201 cartage , erection and dismentling charges 22% of materials cost 202 conversion of 33kv overhead/ underground line by 33kv line underground 203 cable al. 3x300 sq.mm. xlpe 33 kv 204 stp 11m-is 410 sp-55 205 g.l pipe 6 dia 206 m.s.top channel 100x50x2240 mm 207 hdpe pipe 200 mm dia pe 80, pn-6 208 service clamp o/s 209 clamp for fixing pipe to pole 210 bracing angle 65x65x6x4300 mm with clamp 211 33 kv cable jointing kit 3x300 se mm outdoor 212 33 kv cable jointing kit 3x300 se mm straight through 213 earthing of pole by ms earthing rod of 2ox25o0 mm & 6 swg earthr.ng wire etc. 214 m.s. nut & bolt with washer 215 number plates with clamp 216 danger board & clamp with bolts & nuts 217 stay complete (stay rod 15x1800mm, stay wire 5 kg,, stay clamp, boult & nut rvith grouting 218 daner bqard barbed wire includin jumpering 219 carriage , layrng of 3x300 sq.mm size 33 kv xlpe insulated cable underground in hdpe pipe dia 200 mm. 220 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 221 grouting of st pole 222 grouting of stay set 223 cartage , erection and dismentling charges 22% of materials cost 224 installation of 250 kva transformer on dp for the shifting of 3 no. 250 kva. 9 no.400 kva & 3 no. 630 kva transformer 225 stp 11m-is 410 sp-55 226 ms channel 100x50x2240 mm 227 service clamp for round pole 228 m.s. bolt and nuts off size with washer 229 l.t. cable 3.5ox4oo so m 230 ltxlpe insulated,unarmoured aluminium singlc corc cable,1x240sq. mm.sizc 231 lt xlpe insulatcd,unarmoured aluminium singlc core cablc,1x400 sq. mm.size 232 earthing of 250 kva t/f with g.i. pip[ 233 earthing rod complet. 234 1 1 kv d.o. fi]se sets 235 1 1 kv tpmo 236 d.d. wire 70 qs mm 237 250 kva t/f 238 l.t. cubical b0x complete 239 l,t. cable 3.50x240 sq mm 240 stay set complete, 241 aluminimum lug 70 sqmm 242 aluminimum lug 240 sqmm 243 aluminimum lug 400 sqmm 244 pvc tape 245 t/f bushing connector of copper strip 246 labour , cartage & errection charges and dismentaling of existing t/f 247 dismentling and cartage from site to store charges 7% (other misclenous charges)