Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Tube Inner
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of tube-inner Tenders

List of latest tube-inner Tenders in Indian Tenders. Click on any tube-inner Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for tube-inner Tenders.

Advance Search
  • All-Tenders (33)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
31 Defence
image image
Statutory Bodies and Commissions/Committees
TRN :48666242 |  17 May, 2025
Tender Value : 0
 Darjeeling - West Bengal
Tender for bids are invited for drill bits 1 by 8 inch in packet of 10 nos , ring spanner 14 x 15 , ring spanner 16 x 17 , d spanner 15 to 16 , d spanner 17 to 18 , rope 20 mm , ball pin hammer 1 kg with wooden handle , insulated electric pliers 6 inch , hack saw frame , hack saw blades , aluminum spirit level 6 inch long , bolting machine , monkey ladder , pgi tool box of size 60cm x 45cm x 30cm , silicon gun , measuring tape metallic 15 mtr long , screw tapping drill bit for drill machine , plum bob , water leveling pipe transparent pvc 100mtr long , bucket gi 10 ltrs capacity , tasla pan mortor , hand gloves , silicon tube , angle steel footing , bottom track size 2257 , bottom track size 2200 , gable bottom track size 3125 , arch panels 0 point 8 mm size 2260 , arch panels 0 point 8 mm size 2460 , arch panels 0 point 8 mm size 1660 , arch panels 0 point 8 mm size 3860 , gable panels 0 point 6 mm size 3800 , gable panels 0 point 6 mm size 4200 , gable panels 0 point 6 mm size 4500 , gable panels 0 point 6 mm size 4900 , gable panels 0 point 6 mm size 5100 , gable panels 0 point 6 mm size 5200 , gable panels 0 point 6 mm size 3100 , outer arch flashing 0 point 8 mm size 2260 , outer arch flashing 0 point 8 mm size 2460 , outer arch flashing 0 point 8 mm size 1660 , outer arch flashing 0 point 8 mm size 3860 , inner arch flashing 0 point 8 mm size 2260 , inner arch flashing 0 point 8 mm size 2460 , inner arch flashing 0 point 8 mm size 1660 , inner arch flashing 0 point 8 mm size 3860 , thick door flashing 2 mm size 2150 , thick door flashing 2 mm size 1800 , door with puf shelter size 1750 x 2150 , frp 3mm turbovents base 1660 mm , turbovents 12 inch , nut bolt 10 x 20 , ht nbw 12 x 45 , sds screw 12 to 14 x 25 2 59 , chapati plate with puffer (v2) total quantity : 74502
  • View Tender
  • Document
  • Bid Support
32 Housing Urban And Rular Development
image image
Local Bodies
TRN :48606691 |  15 May, 2025
Tender Value : 56.65 Crore
 Prayagraj - Uttar Pradesh
Tender for tender for kareli - nurulla road to askari market road block c and block d housing scheme and nurulla road from mahavir chauraha to karamat ki chowki near sasur khedari river and also till the connecting road - clearing grass and removal of rubbish upto a distance of 30 m outside the periphery of the area as per technical specification clause 201. 3 dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 60 metres as per instructions of e-i-c. (by mechanical means). 4 i) cement concrete 5 ii) reinforced cement concrete/ r.b. 6 dismantling of flexible pavements and disposal of dismantled material up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per technical specification clause 202. bituminous / granular courses (by mechanical means) 7 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 8 removing all type of hume pipes and stacking within a lead of 1000 metres including t&p, earthwork and dismantling of masonry works. 9 (i) up to 600 mm dia 10 removal of telephone / electric poles / street light / lamp post including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately 11 disposal of moorum/building rubbish malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of engineer-in-charge. note- item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 12 dewatering using 10hp to 70hp diesel engine pump set including hire charges, cost of diesel, engine oil, pump operator, labor charges, conveyance of pump set and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (hire charges for diesel pump set for 10 hp) 13 [b] bill no. 2 - earthworks 14 excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and leading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location within all lifts and lead upto 1000m 15 removal of unserviceable soil including excavation loading and disposal but excluding replacement by suitable soil which shall be paid separately as per clause 305 16 i) lead upto 1000 m 17 ii) lead upto 8000 m 18 earth work in excavation of foundation of structures as per drawing and technical specification, including setting out construction of shoring and bracing, removal of stumps and other deleterious matter dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for road work. 19 mechanical means (depth upto 1.5 m) 20 i) excavation 21 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 22 [c] bill no. 3 - development of carriageway 23 stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with irc-sp-72-2015 , irc-37-2012 & 2018 and irc sp 89 (part ii) 2018. cementitious additive @ rate of minimum 5 - 7% and ccs/cs additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. the additive spreader shall have variable working width sufficient to cover whole pavement lane. the in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. the resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per irc 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. the entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. the tandem roller be followed by pneumatic tyre roller. the minimum unconfined compressive strength (ucs) of stabilized sub base/ base should be 4.5 to 7 mpa after 7 / 28 days of curing as per irc-sp- 72-2015 , irc-37-2012 & 2018 . also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the gradation mixes and materials should be as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the train of equipments to be used are binder spreader- water tanker- additive truck- recycler- padfoot roller (20 tonne) + single drum compactor- grader- tandom roller- pneumatic tyreroller (20 tonne) 24 sami layerproviding and laying stress absorbing membrane interlayer (sami)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of claues 703-3, laid over a tack coat of paving grade bitumen 80- 100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement surface. 25 providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (tack coat on bituminous surfaces ) 26 providing and laying 40mmthickbitumencarpete(b.c.) with 100-120 tph hot mix plant producing and average output of 75 tonege par hour using crushed aggregates of specified grading premixed with bitumen binder(vg-30) @ 5.40% of mix as per most specification clause. etc all comp of work. 27 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from aggregat aggregate natural sources, portland pozzolana/ordinary portland/portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall. be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 28 m.s. (tor steel or plain) in plain work such as rcc or rb work including binding for proper shape and including supply of steel and its wastage bend, hooks and authorized overlapping shall be measured and including cost of binding wire. excluding gst (sor-504). 29 [d] bill no. 4 - pedestrian infrastructure (footpath) 30 sand filling in foundation trenches as per drawing & technical specification and as per direction of engineer-in-charge. (including beneath all paver blocks, cobble areas for levelling purpose, etc.) 31 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. (pcc below all paving area, kerb channel, road edge kerb, table top, property edge beam) 32 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 33 i) for grading-i material 34 plain/reinforced cement concrete in open foundation complete as per drawing and technical specifications, pcc grade m30using batching plant transit mixer & manual placing(80 mm thickness) r & manual placingand giving broom finish. (pcc with broom finish thickness 80 mm) 35 providing and laying 75mm thick m-30 grade batch mix cement concrete and applying stamping finish to the top surface of freshly laid plain/ reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the engineer-in-charge. the process shall include the following:-the concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. the approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. the approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. these stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the hole surface to be stamped is completed within the time while concrete is in plastic stage of setting.after stamping, the curing shall be done as per manufactures specifications. after initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per theequirement. the surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.the construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (pu) polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (cost of concrete for flooring is not included in this item which shall be paid separately.) 36 80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 37 supply and fixing of tactile indicators made from ss-304 grade stainless steel. warning tactile indicator shall be installed on the walking surface in a raised grid pattern of dots or stud. minimum 36 studs to be placed in 300x300 mm area. dimensions - 35mm outer dia x25mm inner dia, stem dia 8mmx12mm, weight - 28grm.all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property, all complete as per direction of engineer-in-charge. 38 supply & fixing of tactile indicators made from ss-304 grade stainless steel. directorial tactile indicator shall be installed on walking surface, consisting of a series of raised bar/strip. min 4 bars/strip to be placed in direction perpendicular to distance of travel in 300x300 mm area. dimensions-280mm l x 35mm w x 4.5mm, stem dia 8mmx12mm, weight - 250grm all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property., all complete as per direction of engineer-in-charge. 39 providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to is : 15622 of approved make in all colors and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer-in-charge 40 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (dsr-11.20) 41 providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of engineer-in-charge. (saucer drain along the road edge, curved kerbs at property entry/exit, curved kerbs at side roads) 42 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 43 cc grade m20 using batching plant transit mixer & manual placing all complete as per direction of e-i-c. 44 [e] bill no. 5 -parking 45 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 46 i) for grading-i material 47 supplying and filling in plinth with sand under floors/in trenches, including watering, ramming, consolidating and dressing all complete with material (from source to site), labor and t&p etc. required for proper completion of the work. (including royalty). 48 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days and giving broom finish. (pcc) 49 providing and laying factory made chamfered edge cement concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using pu mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of engineer-in-charge.80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 50 [f] bill no. 6 -cycle track 51 nil 52 [g] bill no. 7 - traffic signs, markings and other road appurtenances 53 providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow ms tube posts/horizontal members/bracings covered with 1.63mm thick ms sheet. the sheet shall be fixed with 30x5mm ms flat by suitable welding/riveting. the panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. ms channel islc 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long ms angle 40x40x6mm bracing. suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. the work shall be executed as per drawing/direction of engineer-in-charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the engineer-in-charge. the barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of engineer[1]in-charge.(note :- one time payment shall be made for providing barricading from start of work till completion of work i/c shifting. the barricading provided shall remain to be the property of the contractor on completion of the work). 54 reflective raised pavement markers (cat eye/ road stud) supply and fixing of raised pavement marker with made of plastic body of rpm/ road stud shall be moulded from asa (acrylic styrene acrylonitrile) or hips (high-impact polystyrene) or acrylonitrile butadiene styrene (abs) or any other suitable material approved by the engineer. the marker shall support a load of 13,635 kg tested in accordance with astm d4260. the reflective panels shall consist, of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face. lenses shall be moulded of methyl methacrylate conforming to astm d788 of equivalent. the slop or retro-reflecting surface shall preferably ba 5+/.5 degree lo base and the area of each retro -reflecting surface shall not be less than 13.00 $q.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & width shall not exceed 130 mm the base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. the contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the engineer . in addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. in case the markers are, displaced , damaged . get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the engineer , at his own cost. the rate shall include all materials, labor, t&p, transportation, installation and incidentals all complete as per direction of the engineer-in-charge, 55 rpm with shank 56 solar power road marker the solar studs shall be made of aluminum alloy and polycarbonate material which shall be absolutely weather resistant and strong enough to support to load of 13,635 kg tested in accordance with astm d4280. its color may be white, red, yellow, green or blue or combination as directed by the engineer. its water resistance shall meet the requirements of ip 65 in accordance with is: 12063:1987 category 2 for the protection against water ingress. the dimensions of solar studs shall not be less than 100 mm * 100 mm * 10 mm. it shall have super bright leds so as the provide long visibility from a distance of more than 800 m. its flashing rate shall not be less than 1 hz. its should be able to give the prescribed performance in the temperature range of -40 degree c to +55 degree c. its life shall be not less than 3 years. the rate shall include all material, labor, equipments, fabrication, transportation erection, installation and incidentals all complete as per direction of the engineer-in-charge 57 r.cc work (1:1.5:3) (m-20) with cement course sand &20mm the stone grit including all complete cement concrete with cement sand &20mm gauge stone grit with the proportion of (1:1.5:3)including all complete the work (morth ra-12.8 c, case-ii) 58 m.s. or iron work plain or tor for rcc work including cutting, bending, rivetting or welding etc. where necessary. excluding gst (s.i.no-504) 59 painting two coats on new concrete surfaces - painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 60 m.s. or iron work of heavy sizes section such as trusses, built up gates, record racks, roof work, gates etc. including rivetting or welding where necessary. excluding gst (s.i.no-503) 61 painting of m.s. grill with enamul paint etc all complete work. (s.i. 15.15 new item no.) 62 providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 63 providing and fixing of retro- reflectorized cautionary, mandatory and informatory sign as per irc :67 made of high intensity grade sheeting type-ivvide clause 801.3, 2mm thick aluminum sheeting, 1.5 mm thick supported on mild steel angle iron post 75mm* 75mm *6mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45cm* 45cm*60 cm, 60 cm below ground level as per the approved drawing. the retroreflective sheeting shall be tested for a certificate of having the sheeting coefficient of retro reflection, daytime, color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoors weathering and its having passed these tests shall be obtained from international/ government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should be also obtained from indian condition within 3 years of launching ofproduct by the manufacturing abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirement from a reputed laboratory in india can be accepted provisionally. in such a situation , the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per irc 67:2012 . legends, letters, numerals, and borders etc. should be as per mort&h specification 801.3.7. proof of the same in form of government reports shall be uploaded while quoting tender. 64 90 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 65 60 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 66 60 cm circular with diffinitation plate size (20cm x 60 cm) 67 80mm x 60mm rectangularwith diffinitation plate size (20cm x 60 cm) 68 60 mm x 45 mm rectangularwith diffinitationplate size (20cm x 60 cm) 69 60cm x 60cm square with diffinitation plate size (20cm x 60 cm) 70 90 cm high octagon 71 direction and place identification signs up to 0.90 sqm size board providing and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/ client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area not exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60cm., below ground level as per approved drawing, complete. 72 direction and place identification signs with size more than 0.90 sqm size boardproviding and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility. liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing, complete. 73 providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per irc :67 74 brick masonry work in cement mortar 1:4 (1cement: 4 coarse sand) in foundation complete with cement concrete bricks procured from c&d waste recycling plant baswar excluding pointing and plastering, as per drawing and technical specifications. 75 struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 finerness modulus.sor 2022 si no574 76 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 sand)and as per direction of engineer in charge. 77 finishing walls with ready mixed premium acrylic emulsion paint (company depot tinted) having volatile organic compound (voc)less than 50 gm/liter and uv resistance as per is 15489:2004, alkali, & fungal resistance, dirt resistance exterior paint of required shade with silicon additive(for painting wall, street furniture) new work (two or more coats applied @1.43 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm) 78 supplying and fixing of cast iron antique style bench having weight of sides not less than 72 kg (36 kg each) fitted with fibre rectangle strip (should not be less than 50 mm x 25 mm and 1.6mm thick. length of bench should not be less than 6 ft (end to end of castiron support). 79 [h] bill no. 8 - utility and street light cabling 80 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(pcc below pipe of storm water, sewer, water, inspection chamber for storm water, telecom chamber, power chamber and sewer) 81 providing and laying non pressure np-3 class (medium duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (storm water, sewer) 82 600 mm dia rcc pipes 83 providing of 7- way 40mm multi ducts with solid permanently solidly lubricated silicone in inner layer for ict fiber cables conforming to astm f 2160, astm d 2444 and /or equivalent indian standard. external sheathshall be in orange colorand shall be free from visual defects like blisters, shrink holes,flaking, scratches, groove lines & surface roughness. the color of the 7 nos. plb hdpe ducts shall be green, blue, yellow, brown, violet, grey , red for differentiation. outer sheet thicknessshall be 1.2mm +/-0.2mm. the inner surface of the multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. wall thickness(mm) of each of the ducts excluding rib height shall be 2.9mm +/- 0.3mm. iso requirements- iso 9001, 14001, 18001, complete as per specifications and directions of engineer-in-charge. (7 way multi utility duct for ofc) 84 supply of hdpe pipe of size 110mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.110mm dia hdpe pipe pn-6 class pe-100 85 supply of hdpe pipe of size 63mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.63mm dia hdpe pipe pn-6 class pe-100 86 rcc grade m20 using batching plant transit mixer & manual placing ( side wall, bottom slab for all inspection chamber i.e. storm water, telecom, power, sewer, water) 87 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class b125 having minimum load capacity 125 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. 88 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class d400 having minimum load capacity 400 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. (storm water) 89 supply and fixing gully grates red 048 grh – 300* 750mm d.i. gully grate & frame in d400 load class , as per bs en 124 black bitumen paint, all complete as per direction of engineer-in-charge. 90 constructing rcc rectangular type manholewith a floating coat of neat cement, foundation concrete 1:6:12mix (1 cement : 6 coarse sand : 12 graded brick bats 40 mm nominal size), and making necessary channel in cement concrete of m-25 grade finished with a floating coat of neat cement, all complete as per standard design and instruction of e-i-c. 91 restoration of water pipeline in case of damage 92 [i] bill no. 9 - horticulture / landscaping works 93 trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 94 supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 95 supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 96 mixing earth and manure in specified proportion or as directed. 97 rough dressing the trenched ground including breaking the clods. 98 fine dressing the ground 99 spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 100 uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 101 providing & laying selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 102 preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of officer-in-charge. 103 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 104 providing and stacking of nauclea cadamba (kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 105 providing and stacking of nyctanthes arbor-tristis (hasingar) of ht. 90-105 cm in earthen pots of size 20 cm as per direction of the officer-in-charge. 106 providing and stacking of terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 107 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 108 providing and stacking of plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 109 providing and stacking of ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 110 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 111 providing and stacking of duranta golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge.. 112 providing and stacking of tradescantia zebrina having in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 113 providing and stacking of wedelia trilobata,full of leaves in 15 cm size ofpoly bags & as per direction of the officer-in-charge. 114 providing and stacking of asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of earthen pot / plastic pot & as per direction of the officer-in-charge.. 115 providing and stacking of ophiopogon jaburan ( variegated ), full of variegated leaves in earthen pot/plastic pot of size 20 cm. as per direction of the officer-in-charge. 116 providing and displaying of croton petra bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 117 providing and fixing ms iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 nos (25 x 6 mm) and 8 nos (25 x 3 mm) vertical ms riveted to 3 nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of priming, complete in all respects. 118 street light works (excluding gst) 119 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 mtr length) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p complete in all respect 120 supply and fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. confirming to ip 66 protection complete in all respect. cat: aaa 121 supply and laying of 16 sq.mm. 4 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 122 supplying and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 123 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 124 making connection of each street light by s/l 1.5 sqmm frlsh copper wire complete as per direction of engineer in charge. 125 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with double arm bracket (1 mtr length each ) on rcc foundationincluding the cost of foundation, foundation bolts, excavation & back filling and required t&p completee in all respect. 126 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 127 supply and fixing for automatic street light cubical control juction box painted with anti-corrosive alkali and acid proof pait consisting of 6 amps mcb (b - curve) complete in all respect 128 supply and fixing of 16 sq.mm plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 129 supply and fixing of 40 amp. capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 130 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. 131 supply/ erection of surface mounted decorative pole 4500 mm long having base plate 300x300x12 mm with the bottom dia 139 mm upto 1 mtr long with the thickness of 3.6 mm and the top dia is 76 mm upto 3.5 mtr. log. decorative pole made out of galvanized iron tube with cast aluminium embellishments. the poles are painted with polyturetnane paint. the pole have service window at the bottom on the pole for housing the mcb and terminal strips and as per attached drawings. 132 s/f of single arm decorative bracket 100 mm long made of cast iron/ aluminium embellishments painted with polyturetnane paint. 133 supply of led decorative drop down light made of aluminium housing fitted with polycarbonate diffuser having 500 mm dia with 70 w. 134 supplyandlayingof aluminiumconductorpvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 135 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 40 a tpn 136 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 16 sq. mm 137 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 138 supply and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 139 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 140 part - b utility shifting (including gst) 141 converstion of lt overhead line by underground lt line 142 lt xlpe insulated cable of size 3.5x400 sqmm. 143 lt xlpe insulated cable of size 3.5x240 sqmm. 144 lt xlpe insulated cable of size 3.5x150 sqmm. 145 lt xlpe insulated cable of size 3.5x70 sqmm. 146 9 mtr long stp 147 hdpe pipe 140mm dia peb0, pn-6 148 hdpe pipe 120 mm dia peb0, pn-6 149 hdpe pipe 75 mm dia p880, pn-6 150 aluminium crimping lugs 400sqmm 151 aluminium crimping lugs 240sqmm 152 aluminium crimping lugs 150sqmm 153 aluminium crimping lugs 70sqmm 154 6 swg g.l. wire for earthing along cables. 155 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x400 sqmm. lt cable 156 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x240 sqmm. lt cable 157 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x150 sqmm. lt cable 158 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x70 sqmm. lt cable 159 main lt panel at sub station- 400 kva (type a-2)lncomer- 1 set of 800 amp. tp mccb with spreader & extended handlemetering on lncomer - 1 set of digital ammeter with ass- 1 set of digatal voltmeter with vss- 1 set of led type phase lndicating light (22.5 mm.)with control mcbsoutgoing- 6 set of 250 amp. tp mccb with spreader & extended handte( 5 nos. + 1 no. for capacitor panel)- 2 set of 100 amp. tp mccb with spreader & extended handle 160 main lt panel at sub statton- 250 kva (type a-2) lncomer- 1 no. 630 amp. tp mdo acb with inbuilt mpr release with i ontoff tnai.ating lightmetering on lncomer - 1 set of digital ammeter with ass- i set oldigital volt-meler wirh vss- 1 set of led type phase indicating light (22.5 mm.j with control mcbs outgoing - 5 set of 250 amp. tp mccb with spreader & exrended handle- 2 set of 100 amp. tp mccb with spreader & extended handle flnstallation oflt distribution boards for lt underground system (type a,b&cj) 161 supply , installation, testing & commissioning of outdoor type feeder pillar panetto be made of 2 mm crca sheet and covers will be j.6mm crca sheet dulypowder coated paint with 300 amps al. busbar. (type-b2)lncomer - 250 amp. tp mccb - 1 no.outgoing - 63 amp. tp mccb - 5 nos.lnstallation of lt distribution boards forlt underground system (type-a, b & c) 162 outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. [type-b3] incomer - 100 amp. tp mccb - 1 no. outgoing - 63 amp. tp mccb - 4 nos.lnstallation of lt distribution boards for lt qnderground system [tvpe-a, b & cl 163 lockable distribution boxes of size 450x400mm with bus bar 100 amp. tpn to feed upto 10 houses (type c) 164 xlpe lt service armoured cable for single phase,2x6 sq. mm.(pvc armoured consumer service cablel 165 xlpe lt service armoured cable for single phase,2x10 sq. mm.(pvc armoured consumer service cablej 166 xlpe lt service armoured cable for three phase,4x10 sq. mm.[pvc armoured consumer service cablel 167 xlpe lt service armoured cable for three phase,4x1.6 sq. mm.(pvc armoured consumer service cablel 168 xlpe lt service armoured cable for three phase,4x25 sq. mm.(pvc armou[ed consumer service cable) 169 pvc pipe 32 mm dia 170 pvc pipe 50 mm dia 171 electronic kwh meter 1px2w with box. for single phase consumer 172 electronic kwh meter 3px4w static meter with box.for three phase consumer 173 carriage , laying of 3.5cx400 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 140 mm dia. 174 carriage, laying of 3.5cx150/240 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 1.20 mm dia. 175 carriage ,laying of 3.5cx70 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 75mm dia. 176 painting of stp incuding paints [2 ltr red oxide and 2 ltr alluminum paint for each pole.l 177 grouting of st pole 178 cartage , erection and dismentling charges 22% of materials cost 179 conversion of 11kv overhead/underground line by 11kv line underground 180 11 kv cable size 3x185 sq.mm xlpe 181 stp 11m-is 410 sp-55 182 g.l pipe 4 dia 183 top channel 100x50x2240 mm 184 hdpe pipe 160 mm dia pe 80, pn-6 185 service clamp o/s 186 clamp for fixing pipe to pole 187 11 kv cable jointing kit size 3x185 sq.mm xlpe o/d 188 11 kv cable jointing kit size 3x185 sq.mm xlpe s/t 189 earthing complete. 190 m.s. nut & bolt with washer 191 bracing angle 65x65x6x2700 mm with clamp 192 stone pad 193 number plates with clamp 194 danger board & clamp with bolts & nuts 195 stay complete 196 g i barbed wire 197 carriage , layrng of 3x185 sq.mm size 11 kv xlpe insulated cable underground in hdpe pipe dia 160 mm. 198 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 199 grouting of st pole 200 grouting of stay set 201 cartage , erection and dismentling charges 22% of materials cost 202 conversion of 33kv overhead/ underground line by 33kv line underground 203 cable al. 3x300 sq.mm. xlpe 33 kv 204 stp 11m-is 410 sp-55 205 g.l pipe 6 dia 206 m.s.top channel 100x50x2240 mm 207 hdpe pipe 200 mm dia pe 80, pn-6 208 service clamp o/s 209 clamp for fixing pipe to pole 210 bracing angle 65x65x6x4300 mm with clamp 211 33 kv cable jointing kit 3x300 se mm outdoor 212 33 kv cable jointing kit 3x300 se mm straight through 213 earthing of pole by ms earthing rod of 2ox25o0 mm & 6 swg earthr.ng wire etc. 214 m.s. nut & bolt with washer 215 number plates with clamp 216 danger board & clamp with bolts & nuts 217 stay complete (stay rod 15x1800mm, stay wire 5 kg,, stay clamp, boult & nut rvith grouting 218 daner bqard barbed wire includin jumpering 219 carriage , layrng of 3x300 sq.mm size 33 kv xlpe insulated cable underground in hdpe pipe dia 200 mm. 220 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 221 grouting of st pole 222 grouting of stay set 223 cartage , erection and dismentling charges 22% of materials cost 224 installation of 250 kva transformer on dp for the shifting of 3 no. 250 kva. 9 no.400 kva & 3 no. 630 kva transformer 225 stp 11m-is 410 sp-55 226 ms channel 100x50x2240 mm 227 service clamp for round pole 228 m.s. bolt and nuts off size with washer 229 l.t. cable 3.5ox4oo so m 230 ltxlpe insulated,unarmoured aluminium singlc corc cable,1x240sq. mm.sizc 231 lt xlpe insulatcd,unarmoured aluminium singlc core cablc,1x400 sq. mm.size 232 earthing of 250 kva t/f with g.i. pip[ 233 earthing rod complet. 234 1 1 kv d.o. fi]se sets 235 1 1 kv tpmo 236 d.d. wire 70 qs mm 237 250 kva t/f 238 l.t. cubical b0x complete 239 l,t. cable 3.50x240 sq mm 240 stay set complete, 241 aluminimum lug 70 sqmm 242 aluminimum lug 240 sqmm 243 aluminimum lug 400 sqmm 244 pvc tape 245 t/f bushing connector of copper strip 246 labour , cartage & errection charges and dismentaling of existing t/f 247 dismentling and cartage from site to store charges 7% (other misclenous charges)
  • View Tender
  • Document
  • Bid Support
33 Health And Family Welfare
image image
Statutory Bodies and Commissions/Committees
TRN :48330395 |  15 May, 2025
Tender Value : 2.00 Crore
 Shillong - Meghalaya
Tender for cardiac stents and consumables, on consignment basis , group –a1 consumables & accessories, etc , puncture needle for vascular access • 18g • 6-7.5 cm long • 0.038 inch guide wire compatible • should be supplied individually packed • needle should have protected plastic tube covering , puncture needle dedicated for radial artery access • 20-22g • 3-5 cm long • 0.021 or 0.025 inch guide wire compatible • should be supplied individually packed • needle should have protected plastic tube covering , doppler puncture needle (with facility of detecting doppler signals of vascular structures) , special puncture needle with facility of detecting ultrasound images of vascular structures) , introducer sheath for adults (size 4fr.-9fr.) (standard length) • sizes 4french/5 french /6 french /7 french /8 french /9 french. • 10-11 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , introducer sheath with puncture needle for adults (size 4fr.-9fr.) (standard length) • sizes 4french/5 french /6 french /7 french /8 french /9 french. • 10-11 cm long • pack must include 18 g, 6-7.5 cm long puncture needle • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , introducer sheath for adults (size 10fr.-11fr.) (standard length) • 10fr.& 11 fr. • 10-11 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , introducer sheath for adults (size 12fr. and higher) (standard length) • 12fr/13 fr./14 fr. and higher • 10-11 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , long introducer sheath (20-30 cm long) (size 5fr.-9fr.) • sizes 5 french /6 french /7 french /8 french /9 french. • sheath should be between 20-30 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , long introducer sheath (20-30 cm long) (size 10fr.-11fr.) • 10 french & 11 french • sheath should be between 20-30 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , patient transfer and or table super absorbent sheet having loading capacity upto 150 kg size 210x80cm • composite of air formed nonwoven and cross-linked acrylate copolymer. • hotmelt adhesive based hydrocarbons, styrene, rubber copolymer and resin. • loading capacity of 150kg • dimension of 210cm x 80cm absorption capacity of 1.5 ltr , extra thin floor cover made with clean, extremely absorbent cellulose-based material having thermo-mechanic fibre connectors without adhesive and binding agents for freely and swiftly absorption of fluid, non-slip backside, retains 1.5 to 1.7 ltr of fluids • supercore having cellulose and sodiumpolycarylate bonded with thermo-mechanic fibre connectors without any adhesive and binding agents • pp-nonwoven hydrophiliated surface and rear side • quick absorption facility with long-term binding of large quantities of liquid upto 1.7 ltr • extra thin and individual cuttable • easy in use on floors, tables and beds in operating theatres during medical examinations • facility to absorb fluids from both sides • non-slip proof backside having size of 116cm x 76cm , breathable fluid and germ impermeable, skin friendly having smooth surface transfer and repositioning sheet retains upto 1.9 ltr of fluids and upto 100kg weight capacity • odourless, insoluble fluid and germ impermeable skin friendly • supercore® technolgoy composite of 76% cellulose and 24% sodiumpolyacrrylate for impressive absorbency and excellent fluid dispersion than conventional airlaids • having weight of ca. 295g • having loading capacity upto 100kg with dimension of 80 x 210cm having absorption capacity of 2900 ml/pc or 1800ml/m2 , radiation protection body contoured endoskeleton with 0.5mm lead equivalence. bilayer for protection, with mantis arms, proprietary illiac crest belt for efficient weight redistribution ensuring no weight on the shoulders and spine • bilayer with mantis arms, iliac crest belt for efficient weight redistribution to ensure no weight on shoulder and spine • made with highest quality core material product in lead and non-lead materials • having durable and flexible endoskeleton • having comfort and adjustable belt with memory foam interior and spacer mesh to help regulate users temperature • available in 0.5mm lead equivalence available in small, medium, large and x-large stocked , group –a2 , long introducer sheath (20-30 cm long) (size 12fr. and higher) • 12fr./13 fr./14 fr. and higher • sheath should be between 20-30 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , long introducer sheath (30-50 cm long) (size 5fr.-9fr.) • sizes 5 french /6 french /7 french /8 french /9 french. • between 30-50 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , long introducer sheath (30-50 cm long) (size 10 fr.-11fr.) • sizes of 10 french & 11 french • between 30-50 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , long introducer sheath (30-50 cm long) (size 12 fr. and higher) • sizes of 12 french/13 french/ 14 french and higher • between 30-50 cm long • 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , extra long introducer sheath (> 50 cm) (size 5fr.-9fr.) • 5 french /6 french /7 french /8 french /9 french. • more than 50 cm long • 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak and airaspiration • integral side port with attached 3-way stopcock • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , extra long introducer sheath (> 50 cm) (size 10 fr.-11fr.) • sizes of 10fr.& 11 fr. • more than 50 cm long • 0.035 or 0.038 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • integral side port with attached 3-way stopcock • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , extra long introducer sheath (> 50 cm) (size 12fr.and higher) • sizes of 12fr./13 fr./14 fr. and higher • more than 50 cm long • 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak and airaspiration • integral side port with attached 3-way stopcock • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • with smooth and resistance free insertion , introducer sheath dedicated for trans radial access • sizes from 4french/5french/ 6 french/7 french • between 7-11 cm long • 0.021 or 0.025 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • with integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • should have smooth and resistance free insertion , long introducer sheath dedicated for transradial access • sizes from 4french/5french/ 6 french/7 french • between 16-24 cm long • 0.021 or 0.025 inch guide wire compatible • with haemostatic valve to prevent back leak and air aspiration • with integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • should have smooth and resistance free insertion , transradial introducer kit • includes 21 g puncture needle • 0.021 inch introducer guide wire • introducer sheath sizes from 4french/5french/ 6 french/7 french • sheath size between 10-24 cm long , group - a3 , ptfe coated diagnostic guide wire - (regular length, regular stiffness) • should be available in 0.025, 0.032, 0.035 and 0.038 inches size • should be between 145-180 cm long • should be available as straight & j-shaped tip • should be available in variable lengths of flexible/floppy end • should be available in variable j tip sizes • should be available in fixed as well as movable core , ptfe coated diagnostic guide wire - (exchange length, regular stiffness) • should be available in 0.025, 0.032, 0.035 and 0.038 inches size • should be 240-300 cm long • should be available as straight or j-shaped tip • should be available in fixed as well as movable core , ptfe coated diagnostic 0.032 inch guide wire - (regular length, extrastiff shaft strength) -amplatz type • should be available in 0.032 inches size • should be between 145-180 cm long • should be available as straight & j-shaped tip , ptfe coated diagnostic 0.032 inch guide wire - (regular length, extrastiff shaft strength) -amplatz type • should be available in 0.032 inches size • should be between 240-300 cm long • should be available as straight & j-shaped tip , ptfe coated diagnostic guide wire - (regular length, extrastiff shaft strength) -amplatz type • should be available in 0.035 inches size and higher • should be between 145-180 cm long • should be available as straight & j-shaped tip , ptfe coated diagnostic guide wire - exchange length, extrastiff shaft strength) -amplatz type • should be available in 0.035 inches size and higher • should be between 240-300 cm long • should be available as straight & j-shaped tip , ptfe coated diagnostic guide wire - regular length,ultra stiff shaft strength) -amplatz super stiff type • should be available in 0.032, 0.35, 0.038 inches size • should be between 145-180 cm long • should be available as straight or j-shaped tip; should have extra ordinary or exceptional shaft strength , ptfe coated diagnostic guide wire - exchange length,ultra stiff shaft strength) -amplatz super stiff type • should be available in 0.032, 0.035 and 0.038 inches size • should be between 240-300 cm long • should have extra ordinary or exceptional shaft strength , pigtail catheter • 4french/5french/6french/7french/8french size • should be available in various lengths , angled pigtail catheter • 4french/5french/6french/7french/8french size • should be available in various lengths , group-a4 , pigtail catheter with marker • 4french/5french/6french/7french/8french size • should be available in various lengths , judkins catheter • 4french/5french/6french/7french/8french size left and right judkins catheters in various standard curves and lengths. , multipurpose catheter • 4french/5french/6french/7french/8french size multipurpose catheter in various standard curves and lengths. , amplatz catheter- 4french/5french/6french/7french/8french amplatz left (al) and amplatz right (ar) catheter in various standard curves and lengths , internal mammary catheter – • 4french/5french/6french/7french/8french in various standard curves and lengths , by- pass graft catheters- • 4french/5french/6french/7french/8french in various standard curves and lengths. , transradial diagnostic coronary catheters - • 4french/5french/6french/7french diagnostic coronary catheters of various curves and lengths dedicated for trans radial coronary angiography , nih catheter- • 4french/5french/6french/7french/8french in various standard curves and lengths. , cournard catheter- • 4french/5french/6french/7french/8french in various standard curves and lengths. , thermo dilution catheter • should be compatible with the available system , group –b1 , ptca inflation device • efficient locking system to maintain high pressure • rapid inflation and deflation • clear barrel for easy visualization of de-bubbling • luminescent analog pressure gauge (up to 30 atm) • ergomatric and user friendly hand held design , tuohy borst (haemostatic y-connector) for ptca- rotating mechanism • should accommodate virtually all interventional devices • large thumb wheel for easy maneuverability • luer connector at the guiding catheter end • rotating adapter at the guiding catheter end , tuohy borst (haemostatic y-connector) for ptca- push mechanism • should accommodate virtually all interventional devices • luer connector at the guiding catheter end • rotating adapter at the guiding catheter end • should have bleed back safety mechanism • stepwise control for open, semi-open and closed position , tuohy borst- double (haemostatic y-connector) for bifurcation ptca • two ports for insertion of interventional devices • luer connector at the guiding catheter end • rotating adapter at the guiding catheter end , large bore tuohy borst (haemostatic y-connector) , ptca guide wire torquer • should hold guide wires from 0.009-0.018 inches • ergomatric and user friendly design , ptca guide wire insertion needle • 20 g size • 10 -12 cm long • should hold up to 0.018 inch guide wire , ptca guide wire accessory kit containing • haemostatic y connector • ptca guide wire torquer • ptca guide wire insertion needle , ptca inflation device with accessory kit containing • ptca inflation device • haemostatic y connector • ptca guide wire torquer • ptca guide wire insertion needle , control syringes for ptca • clear, glass-like plastic syringe • markings up to 10 or 12 ml • palm and finger assisted easy maneuverability • plunger should have resistance free movement • should have a stopper with 0.5 ml reserve , group -b2 , connector tubing (connecting between touhy borst and manifold) • should be between 20- 50 cm • should have large i.d for easy flow of contrast • should take high pressure • should be flexible • should have male and female hubs , manifold for ptca with two side ports • large i.d for easy flow of contrast • smooth resistance free unidirection handle/knob , manifold for ptca with three side ports • large i.d for easy flow of contrast • smooth resistance free unidirection handle/knob , manifold with attached tubings • two side port manifold • one connector tubing for connecting manifold to tuohyborst • one luer lock control syringe (10 or 12 ml) for contrast injection • one large bore tubing (with flow regulating knob) for withdrawing contrast • one three way stop-cock , ptca kit: should contain the following items • one tuohyborst (haemostatic y- connector) • one two side-port manifold • one connector tubing for connecting manifold to tuohyborst • one luer lock control syringe having markings up to 10 or 12 ml for contrast injection • one ptca guide wire insertion needle • one ptca guide wire torquer • one large bore contrast tubing (with flow regulating knob) for attachment between contrast bottleand manifold side port • one pressure monitoring line (150 cm) • one three way stop-cock , femoral compression devices- disc/dome based compression , domes of femoral compression device , ptca guiding catheter- • sizes of 5fr, 6fr, 7fr and 8fr. • all possible shapes including catheters: judkins/femoral left and right, extra back up support,amplatz, voda, multipurpose, hockey stick, transradial interventions, bypass-graft/limainterventions and others • should also have availability of smaller length catheters (90 cm) • should also have availability of catheters with side holes • should also have short tip catheter , large lumen (i.d) ptca guiding cathete (6 french size) • must have i.d of more than 0.070 inch • should have all possible shapes including catheters: judkins/femoral left and right, extra back upsupport, amplatz, voda, multipurpose, hockey stick, transradial interventions, bypassgraft/lima interventions, short tip catheters and others , large lumen (i.d) ptca guiding cathete (7 french size) - • must have i.d of more than 0.080 inch • should have all possible shapes including catheters: judkins/femoral left and right, extra back upsupport, amplatz, voda, multipurpose, hockey stick, transradial interventions, bypassgraft/lima interventions, short tip catheters and others , guide extension catheter with the working length of 150 cm and guide extension segment upto 40cm with 1x1 stainless steel wire braiding with hydrophilic coating and compatible with 6f/7f and 8f femoral guide catheter , group -b3 , ptca guiding catheter for dca , ptca guide wire -regular length, regular shaft support and floppy tip , ptca guide wire -regular length, extra- support shaft and floppy tip , ptca guide wire - exchange length , ptca guide wire- hydrophilic coated, regular length , ptca guide wire- hydrophilic coated, exchange length , special ptca guide wires with elastinite core and stainless steel , shaft support • both regular and exchange length wires • should have wires with varying degree of shaft support , special ptca guide wire with dual coating • should have distal hydrophilic coating and proximal hydrophobic coating • should have wires with variable tip stiffness and variable shaft support , special ptca guide wire with multiple markers for measuring the length of stenotic segment , ptca guide wires for chronic total occlusion (cto) , group -b4 , special non-tapering ptca guide wires for cto with platinum iridiumdistal spring coil • wires available in variable distal tip stiffness, measured in terms of grams , special tapering ptca guide wires for cto with platinum iridiumdistal spring coil • wires available in variable distal tip stiffness, measured in terms of grams , special tapering ptca guide wires for cto withhydrocoathydrophiliccoating • wires available in variable distal tip stiffness , • special hydrophilic ptca guide wires for cto with super elasticalloy (ni-ti) core polyurethrane hydrophilic distal coating , special ptca guide wires for cto, dedicated for retrogradeapproach , extension (doc) wire for approved regular length ptca guide wires , penetration catheters for cto having rotational bluntpenetration , penetration devices for cto by blunt dissection using acuating jaws , ptca guide wire with bidirectional deflectable distal tip , ptca catheter with deflectable distal end • should guide the direction of ptca guide wire , cto reentry system with 2 over the wire lumens and 2 hubs, 3 exit ports for 360 degree functionality for sgr technique 18g • over the wire dual wire lumen micro catheter • 1.5f lesion entry profile* • two separate otw lumens and three exit ports 360 degree guidewire redirection option , dual lumen device for simultaneous haematoma aspiration and redirection of guidewire in true lumen in complex cto cases, 360 degree access • 2.3fx3.3f distal shaft profile and 2.6fx3.4f proximal shaft profile • 0.014” guidewire compatibility • usable length of 140cm additional exit port in the tip lumen of the exit port of the stylet lumen , trapping device for wire trapping used with otw devices with lowest shaft profile of 2f • single use device consisting of hub, shaft and balloon • highly compatible small shaft profile of 2f • designed to trap the guidewire at low inflation pressure depth marker for 90cm guide catheter , intra coronary guide extension catehter • flex zone and unique 3 zone transition for smooth trackability • highest coiling density for extra pushability • 25cm rapid exchange section • two exit markers at 95cm and 105cm working length of 150cm , group -b5 , ptca balloon (non-compliant) - • quote both monorail (rapid exchange) and otw balloons • available in all sizes from 2- 4.0 mm, variable lengths • should have a very high rated burst pressure , special large ptca balloons of more than 4 mm • variable lengths , special ptca balloon catheter with low crossing profile • must have crossing balloon profile of less than 0.025 inches , special ptca balloon catheter of less than 1.5 mm • should be available in variable balloon lengths , special otw ptca balloon for septal ablation for hocm , high pressure cto non compliant with low crossing profile (diameter 0.85mm) assorted sizes) • xr (excellent rewrap) balloon material with ultrathin marker bands • hydro-x hydrophilic coating (distal tip to exit port) • invio coating on guidewire lumen • sub-zero flex tip tapered tip with zero guidewire transition for smooth lesion • 0.85mm diameter • p-tech hypotube with excellent transitional balance, pushability and exceptional kink resistance • crossing profile of 0.0313 inches and tip entry profile 0.0208 inches available in sizes 1.5 – 5.00 mm diameter with length of 10,12,15, 20 & 30mm , group -b6 , ptca balloon for retrograde approach of cto • should be available in both regular and long lengths for retrograde approach , non compliant speciality balloon having the catheter length of 140 cm or more. tip entry profile of 0.019 inch or less and mid- balloon profile of 0.036 inch or less with 3/4 stainless steel cutting blades having a functional height of 0.005 inch. available in a working length of 6, 10 & 15mm and balloon having a working range between 6 to 12 atm. , scoring balloon catheter for ptca , dual wire ptca dilatation catheter , drug eluting ptca balloon using matrix technology , ptca bifurcation balloon , stainless steel coronary stents, premounted on balloon – , stainless steel coronary stents, premounted on balloon – , stainless steel coronary stents, premounted on balloon – , cobalt chromium balloon coronary stents, premounted onballoon – , group -b6- a , coronary stents : non-medicated coronary stent balloonmounted , non-medicated stent on stainless steel platform balloonmounted , non-medicated stent on non-stainless steel platform with uniform ultrathin struts ( up to 60 microns) balloonmounted , non-medicated stent on non-stainless steel platform with uniform thin struts ( 61 to 80 microns) balloonmounted , non-medicated stent on non-stainless steel platform with struts thickness ( > 80 microns) balloonmounted , non-medicated stent on non-stainless steel platform for coronary artery diameters all sizes including 4.5mm or more. balloonmounted , non-medicated stent on non-stainless steel platform for coronary artery disease all lengths including 8mm or less. , group -b6- b -coronary stents : non-medicated coronary stent , balloonmounted , non-medicated stent on stainless steel platform , balloonmounted , non-medicated stent on non-stainless steel platform with uniform ultrathin struts ( up to 60 microns) , balloonmounted , non-medicated stent on non-stainless steel platform with uniform thin struts ( 61 to 80 microns , balloonmounted , non-medicated stent on non-stainless steel platform with struts thickness ( > 80 microns) , balloonmounted , non-medicated stent on non-stainless steel platform for coronary artery diameters all sizes including 4.5mm or more. , balloonmounted , non-medicated stent on non-stainless steel platform for coronary artery disease all lengths including 8mm or less. , group -b6- b.coronary stents : medicated coronary stent -sirolimus eluting , balloon mounted, sirolimus eluting stent with biodurable polymer on stainless steel platform. , balloon mounted, sirolimus eluting stent with biodurable polymer on a non-stainless steel platform. , balloon mounted, sirolimus eluting stent with biodegradable polymer on stainless steel platform. , balloon mounted, sirolimus eluting stent with biodegradable polymer on cocr platform with hybrid stent design and uniform thin struts upto 65 micron, and diameter from 2.25 to 4mm of varying lengths from 10 to 40 mm. , balloon mounted, sirolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform thin struts (61-80 microns) , balloon mounted, sirolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform strut thickness greater than 80 microns. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (upto 60 microns) and diameters of 2.0mm to 4.00 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform thin struts (61 -80 microns) and diameters of 2.0mm to 4.00 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform strut thickness greater than 80 microns and diameters of 2.0mm to 4.00 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (upto 60 microns) and diameters of 2.25mm to 4.5 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (61-80 microns) and diameters of 2.25mm to 4.5 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform strut thickness greater than 80 microns and diameters of 2.25mm to 4.5 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (upto 60 microns) of varying lengths including stent length of 8mm or less. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (61-80 microns)of varying lengths including stent length of 8mm or less , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform strut thickness greater than 80 microns and of varying lengths including stent length of 8mm or less , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (upto 60 microns) of varying lengths including stent length of 48mm or more , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (61-80 microns) of varying lengths including stent length of 48mm or more , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform strut thickness greater than 80 microns and of varying lengths including stent length of 48mm or more , balloon mounted , polymer free, sirolimus eluting stent , group -b6- c - coronary stents : medicated coronary stent -drug eluting , balloon mounted, sirolimus eluting stent with biodurable polymer on stainless steel platform. , balloon mounted, sirolimus eluting stent with biodurable polymer on a non-stainless steel platform. , balloon mounted, sirolimus eluting stent with biodegradable polymer on stainless steel platform. , balloon mounted, sirolimus eluting stent with biodegradable polymer on cocr platform with hybrid stent design and uniform thin struts upto 65 micron, and diameter from 2.25 to 4mm of varying lengths from 10 to 40 mm. , balloon mounted, sirolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform thin struts (61-80 microns) , balloon mounted, sirolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform strut thickness greater than 80 microns. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (upto 60 microns) and diameters of 2.0mm to 4.00 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform thin struts (61 -80 microns) and diameters of 2.0mm to 4.00 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform strut thickness greater than 80 microns and diameters of 2.0mm to 4.00 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (upto 60 microns) and diameters of 2.25mm to 4.5 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (61-80 microns) and diameters of 2.25mm to 4.5 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform strut thickness greater than 80 microns and diameters of 2.25mm to 4.5 mm of varying lengths. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (upto 60 microns) of varying lengths including stent length of 8mm or less. , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (61-80 microns)of varying lengths including stent length of 8mm or less , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform strut thickness greater than 80 microns and of varying lengths including stent length of 8mm or less , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (upto 60 microns) of varying lengths including stent length of 48mm or more , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform ultrathin struts (61-80 microns) of varying lengths including stent length of 48mm or more , balloon mounted, sirolimus eluting stenton non-stainless steel platform with uniform strut thickness greater than 80 microns and of varying lengths including stent length of 48mm or more , balloon mounted , polymer free, sirolimus eluting stent , group -b6- d coronary stents : medicated coronary stent -drug eluting , balloon mounted, everolimus/zotarolimus eluting stent with biodurable polymer on stainless steel platform. , balloon mounted, everolimus/zotarolimus eluting stent with biodurable polymer on non-stainless steel platform. , balloon mounted, everolimus/zotarolimus eluting stent with biodurable polymer on non-stainless steel platform and diameters of 2.25mm or less to 4.00mm or more of varying lengths. , balloon mounted, everolimus/zotarolimus eluting stent with biodegradable polymer on non stainless steel platform. , balloon mounted, everolimus eluting stent with biodegradable polymer on cocr platform with hybrid stent design and uniform ultrathin struts ( upto 63 micron) and diameters of 2.25 to 4.00mm. , balloon mounted, everolimus/zotarolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform thin struts (61-80 microns) , balloon mounted, everolimus/zotarolimus eluting stent with biodegradable polymer on non-stainless steel platform with struts thickness greater than 80 microns. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with ultra thin struts ( upto 60 microns) and diameters of 2.0mm to 4.0mm of varying lengths. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with uniform thin struts ( 61-80 microns) and diameters of 2.0mm to 4.0mm of varying lengths. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with uniform strut thickness greater than 80 microns and diameters of 2.0mm to 4.0mm of varying lengths. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with ultra thin struts ( upto 60 microns) and diameters of 2.25 mm to 4.5mm of varying lengths. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with uniform thin struts ( 61-80 microns) and diameters of 2.25 mm to 4.5mm of varying lengths. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with uniform strut thickness greater than 80 microns and diameters of 2.25 mm to 4.5mm of varying lengths. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with ultra thin struts ( upto 60 microns) of varying lengths including stent length 8mm or less. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with uniform thin struts ( 61-80 microns) of varying lengths including stent length 8mm or less. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with uniform strut thickness greater than 80 microns and of varying lengths including stent length 8mm or less. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with ultra thin struts ( upto 60 microns) of varying lengths including stent length 48mm or more. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with uniform thin struts ( 61-80 microns) of varying lengths including stent length 48mm or more. , balloon mounted, everolimus/zotarolimus eluting stent on non-stainless steel platform with uniform strut thickness greater than 80 microns and of varying lengths including stent length 48mm or more. , balloon mounted , polymer free, everolimus/zotarolimus eluting stent , usfda approved platinum chromium everolimus eluting des with abluminally coated bioabsorbable polymer having a thickness not more than 5?m and a bi segment shaft with a midshaft segment made of lasercut hypotube with the length >10cm and minimum of about 500 lasercuts. should be available in diameters from 2.25 to 5.00mm and lengths of 8,12,16,20,24,28,32,38 and 48mm and the total stent thickness < 90?m. , usfda approved platinum chromium everolimus eluting des specifically designed for left main and large proximal vessels with abluminally coated bioabsorbable polymer having a thickness not more than 5?m and a bi segment shaft with a midshaft segment made of hypotube with lasercuts and a 12 peak design. should be available in diameters from 3.50 to 5.00mm and lengths of 8,12,16,20,24,28 and 32 mm withthe overexpansion capability of minimum 6.00 mm. total stent thickness should be < 95?m , usfda approved platinum chromium everolimus eluting des with permanent polymer having a thickness not more than 5?m and a bi segment shaft with a midshaft segment made of lasercut hypotube with the length of 10cm and about 300 lasercuts. should be available in diameters from 2.25 to 4.00mm and lengths of 8,12,16,20,24,28,32 and 38 mm. , sirolimus coated drug eluting coronary stent. hybrid cell design, cobalt-chromium platform with biodegradable polymer, small strut thickness of 50 ?m 5f guide catheter compatible, with variable diameter and length available upto =48mm , everolimus coated drug eluting coronary stent. hybrid cell design, cobalt-chromium platform with biodegradable polymer, small strut thickness of 50 ?m 5f guide catheter compatible, with variable diameter and length available upto =48mm , sirolimus coated drug eluting tapered coronary stent with 0.5 mm difference of diameter between proximal and distal end.cobalt chromium platform with biodegradable polymer, small strut thickness, different diameter of upto 4.5mm (proximal end ) and length available upto = , group -b6- e. medicated coronary stent -paclitaxel eluting , balloon mounted, paclitaxel eluting stent with biodurable polymer on stainless steel platform. , balloon mounted, paclitaxel eluting stent with biodurable polymer on non-stainless steel platform. , balloon mounted, paclitaxel eluting stent with biodegradable polymer on stainless steel platform. , balloon mounted, paclitaxel eluting stent with biodegradable polymer on non-stainless steel platform. , balloon mounted, paclitaxel eluting stent on non-stainless steel platform and diameters of 2.0mm to 4.0mm of varying lengths. , balloon mounted, paclitaxel eluting stent on non-stainless steel platform and diameters of 2.25 mm to 4.5 mm of varying lengths. , balloon mounted, paclitaxel eluting stent on non-stainless steel platform of varying lengths including stent length of 8mm or less. , balloon mounted, paclitaxel eluting stent on non-stainless steel platform of varying lengths including stent length of 48mm or more. , group -b6- f coronary stents : medicated coronary stent -newer limus analogue ( other than sirolimus, everolimus, zotarolimus) , balloon mounted, newer limus analogue with biodurable polymer on stainless steel platform. , balloon mounted, newer limus analogue with with biodurable polymer on non-stainless steel platform. , balloon mounted, newer limus analogue with with biodegradable polymer on stainless steel platform. , balloon mounted, newer limus analogue with with biodegradable polymer on non-stainless steel platform. , balloon mounted, newer limus analogue eluting stent on non-stainless steel platform and diameters of 2.0mm to 4.0mm of varying lengths. , balloon mounted, newer limus analogue eluting stent on non-stainless steel platform and diameters of 2.25 mm to 4.5 mm of varying lengths. , balloon mounted, newer limus analogue eluting stent on non-stainless steel platform of varying lengths including stent length of 8mm or less. , balloon mounted, newer limus analogue eluting stent on non-stainless steel platform of varying lengths including stent length of 48mm or more. , balloon mounted ,newer limus analogue with abluminal drug coating. , group -b6- g other coronary stents , self - expanding drug eluting coronary stent dedicated for bifurcation lesion. , self - expanding drug eluting coronary stent dedicated for side branch access. , balloon mounted drug eluting , tapered coronary stents. , balloon mounted coronary stents covered with flexible mesh sleeve. , self expanding drug eluting coronary stents. , balloon mounted, dual drug coated drug eluting stents. , bioresorbable coronary vascular scaffold. , coronary stent graft/coronary covered stent with sandwich design of variable diameters and lengths. , coronary stent graft/coronary covered stent of variable diameters and lengths, with single stent design and 5 french guide catheter compatibility. , biodurable polymers includesibs( poly styrene-b-isobutylene -b styrene), pbma( poly-n-butyl methacrylate,peva ( polyethelene covinyl acetate), pvdf-hfp(poly vinlidine fluoride hexafluropropylene,0 pc( phosphoryicholine) siloxane copolymer and any other commercially approved biodurable polymer. , paclitaxel coated semi- compliant drug coated balloon having a drug load of less than 3 ?g/mm2 and a balanced hydrophilic hydrophobic excipient with a bi segment inner lumen shaft and a hydrophilic coating on the shaft. available in the diameters of 2.00 to 4.00 mm and lengths of 12mm, 15mm, 20mm & 30mm. working range of 6 to 14 atm for sizes upto 3.0mm & 6 to 12 atm for 3.50 mm & 4.00 mm. , biolimus aa drug eluting stent system • hybrid cobalt chromium stent • abluminal biodegradable polymer with biolimus a9 eluting stents • mid-section s-shape connectors • thin strut cobalt chromium • 1.37mm large cell opening for easy side branch access • excellent trackability and pushability together with low tip entry profile available in sizes of 2.25, 2.50, 2.75, 3.00, 3.50 & 4.00mm dia with stent length of 9, 14, 19, 24, 29, 33 & 36mm , polymer and carrier free drug coated stent with biolimus a9 (ba9) & microstructured abluminal surface, having lower peak force for better tracebility, higher pushability & large cell opening diameter • polymer free and carrier free drug coated stent • biolimus a9 (ba9) and micro structured abluminal surface • lower peak force for better traceability • higher pushability of 49 pft to increase the efficiency of the force • large cell opening diameter 1.702mm to provides better access to side branch for subsequent stents available in sizes of 2.25, 2.50, 2.75, 3.00, 3.50 & 4.00mm dia with stent length of 8, 11, 14, 18, 24, 28, 33 & 36mm , sirolimus eluting coronary side branch stent system.sizes available 2.5mm x 2.5mm,3.0mm x 2.5mm,3.5mm x 2.5mm, 3.5mm x 3.00mm 4.0mm x 3.5mm lengths 16mm, 19mm, 24mm, & 29mm , group-b10 , rotalink plus (advancer and burr) , rotational atherectomy guide wires , rotaglide lubricant , ivus catheter • should be compatible with available machine of make boston scientific , catheter for virtual histology • should be compatible with available machine , catheter for optical coherence refractometry • should be compatible with available machine , drug delivery/infusion catheter , coronary probing catheter , coronary perfusion catheter , coronary trapeer catheter , group--b11 , special micro -catheter for cto retrograde approach , thrombectomy catheters with manual suction during ptca , thrombectomy catheters with distal balloon occlusion andautomated suction during ptca , thrombectomy catheters with motorized cutting and suction during ptca , doppler wire for ptca , presssure wire for ptca , group-b12 , embolic protection devices based on filter technology/mechanism , embolic protection devices with distal balloon occlusive technology , embolic protection devices with proximal balloon occlusive technology , arterial puncture closure devices - collagen plug based , arterial puncture closure devices - suture based , disposable femoral compression devices- balloon based compression , compression devices for radial artery- balloon based compression , compression devices for radial artery- strap based compression , ptca guide wire re-entry catheter for cto , coronary micro catheter- , group –c (drugs used in cath lab during coronay interventios) , injection nikorandil (2 mg) , injection bivaluridin , injection tirofiban , injection eptifibatide , injection abciximab , group– d1 , puncture needle for vascular access for paediatric / neonatal use • 20-22g • 3-5 cm long • 0.021 or 0.025 inch guide wire compatible • should be supplied individually packed • needle should have protected plastic tube covering , intravenous cannula ‘medicut’ type for vascular access • available in 16, 18, 20, 22 g • supplied with an attached luer-lock 2 ml syringe • individually packed with easy peel off , intravenous cannula for vascular access • available in 16, 18, 20, 22 g • 20 g should allow the passage of 0.025 hydrophilic guide wire • individually packed with easy peel off , intravenous cannula for vascular access in neonates • available in 24, 26 g • individually packed with easy peel off , introducer sheaths for pediatric use (size 4-6fr.) with straight introducer wire • sizes 4french/5french/6 french • between 5.5-7.5 cm long • 0.021 inch straight introducer guide wire • with haemostatic valve to prevent back leak and air aspiration • with integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion • should have smooth and resistance free insertion , introducer sheaths for pediatric use (size 4-6fr.) with j tip introducer wire • sizes 4french/5french/6 french • between 5.5-7.5 cm long • with 0.021 inch introducer guide wire with j tip on one end and straight tip on the other end (bothends should be soft) • with haemostatic valve to prevent back leak and air aspiration • should have integral side port with attached 3-way stopcock • with suture eye for securing sheath • kink resistant • with a dilator-hub lock mechanism to prevent its back-out during insertion • should have smooth and resistance free insertion , introducer sheath of 3 french (fr.) size (for neonatal/ pediatric use) , pigtail catheter (pediatric) - • 4french/5french/6french size • smaller length for neonatal and pediatric use • must be fda approved , judkins catheter (pediatric) - • 4f/5f/6f size left and right judkins catheters in various standard curves and lengths. • must be fda approved , special judkins coronary catheter with 2.5 cm curve (pediatric) • 4f/5f/6f , group-d2 , multiprpose catheter (pediatric) • 4f/5f/6f in various standard curves and lengths , 3- french’ diagnostic catheters for neonatal use • pigtail, judkins, multipurpose, cobra and other diagnostic catheters of 3 fr. size • varying lengths and shapes , special swan ganz catheter with: • 4f catheter should allow the passage of at least 0.021 inch, 5f – 0.025 inch, 6f – 0.035 inch and 7f,8f – 0.038 inch hydrophilic guide wire • must be available in 4f, 5f, 6f and 7f and 8 fr. sizes • catheter should be tapered at tip to ensure uniform diameter of the whole catheter • 10 cm marking along catheter body to confirm insertion depth , balloon tipped angiography catheter , berman cathter • must be available in 4f, 5f, 6f and 7f sizes • should have 6 - 8 holes proximal to the balloon for dye injection • catheter should be tapered at tip to ensure uniform diameter of the whole catheter • 10 cm marking along catheter body to confirm insertion depth , reverse berman catheter • should be available in 4f, 5f, 6f & 7f sizes • catheter should be tapered at tip to ensure uniform diameter of the whole catheter • should have holes proximal to the balloon for dye injection • should have a hole at the proximal tip to allow the passage over the wire , mullins sheath without side arm • should be available in 6 fr./7 fr./ 8fr. sizes • thick and stiff dilator for guiding septal puncture , mullins sheath with side arm • should be available in 6 fr./7 fr./ 8fr. sizes , group-d3 , ptmc balloon ‘inoue type’ with accessories , ptmc balloon of ‘inoue type’ without accessories , ptmc balloon ‘inoue type’ with accessories , ptmc balloon of ‘inoue type’ without accessories- , ptmc balloon ‘inoue type’ with accessories – , ptmc balloon ‘inoue type’ without accessories – , transseptal puncture needle • infants, pediatric and adult sizes • tapering tip • standard curve • hub with angle indicator , group-d4 , asd closure devices with delivery system - • approved for pediatric/adult use • device made of biologically inert material • self-centering, detachable device with delivery cable • available in all the sizes (6 mm – 40 mm) , asd closure device without delivery system , delivery sheath for asd closure device- compatible with the device approved in item no. 27.01 , preloaded asd closure devices - • approved for pediatric/adult use • device made of biologically inert material • preloaded device with delivery cable , asd closure devices with delivery system – • device made of biologically inert material • available in all the sizes , asd closure device without delivery system , delivery sheath for asd closure device- compatible with the device approved in item no at . 27.04 , asd closure device with delivery system – • device made of biologically inert material • available in all the sizes , asd closure device without delivery system – , delivery sheath for asd closure device– compatible with the device approved in item no. at 27.08 , fenestrated asd closure devices , group-d5 , vsd closure devices with delivery system - • approved for pediatric/adult use • device made of biologically inert material • self-centering, detachable device with delivery cable • available in all the sizes , vsd closure devices without delivery system , delivery sheath for vsd closure device - compatible with the device approved in item no.at 28.01 , vsd closure devices with delivery system - • device made of biologically inert material • available in all the sizes , vsd closure devices without delivery system - , delivery sheath for vsd closure device- ce marked compatible with the device approved in item no.at28.04 , vsd closure device with delivery system – • device made of biologically inert material • available in all the sizes , vsd closure device without delivery system – delivery sheath for vsd closure device– compatible with the device approved in item no. at 28.07 , pda closure devices with delivery system - • approved for pediatric/adult use • device made of biologically inert material • self-centering, detachable device with delivery cable • available in all the sizes , group -d6 , pda closure devices without delivery system , delivery sheath for pda closure device - compatible with the device approved in item no.29.01 , pda closure devices without delivery system - • device made of biologically inert material • available in all the sizes , pda closure device without delivery system – , delivery sheath for pda closure device – compatible with the device approved in item no.at 29.04 , pda closure device with delivery system – device made of biologically inert material • available in all the sizes , pda closure device without delivery system – , delivery sheath for pda closure device- compatible with the device approved in item no. at 29.07 , group-d7 , pfo closure device with delivery system – approved for pediatric /adult usedevice made of biologically inert material • available in all the sizes , pfo closure devices without delivery system , delivery sheath for pfo closure device – compatible with the device approved in item no. at 30.01 , pfo closure devices with delivery system - • device made of biologically inert material • available in all the sizes , pfo closure devices without delivery system - , delivery sheath for pfo closure device- compatible with the device approved in item no. at 30.04 , pfo closure device with delivery system – • device made of biologically inert material • available in all the sizes , pfo closure device without delivery system , delivery sheath for pfo closure device– compatible with the device approved in item no. at 30.07 , sizing balloon for device closure – circular shape , sizing balloon for device closure – oval shaped , sizing plate for device closure , group-d8 , delivery cables for asd/vsd/pda devices , retrievers for asd/vsd/pda devices , sheath for retrival of devices , wire 0.018” regular length, regular shaft stiffness • floppy tip • straight / j shaped tip • 140-180 cm long , wire 0.018” regular length, extra- stiff shaft • floppy tip • straight / j shaped tip • 140-180 cm long , wire 0.018” exchange length, regular shaft stiffness • floppy tip • straight / j shaped tip • 240-300 cm long , wire 0.018” exchange length, extra- stiff shaft • floppy tip • straight / j shaped tip • 240-300 cm long , valvoplasty balloon catheters • varying sizes and diameters • approved for pediatric/adult use , special balloon catheter compatible with 4 french sheath • compatible with 0.018 inch guide wire • varying length and diameter , special pediatric valvoplasty balloon catheters compatible with 4 french sheath • compatible with 0.025 inch guide wire • varying length and diameter , group-d9 , valvoplasty balloon catheters (sizes 10 – 22 mm) • approved for pediatric/adult use • varying length and diameter • nominal pressure < 4 atm , balloon catheters (sizes 10 – 22 mm) • approved for pediatric/adult use • varying length and diameter • nominal pressure > 8 atm , balloon in balloon catheter • quote in all sizes , fogarty embolectomy catheter • 4fr/5fr/6 fr sizes • metal rod at tip of the catheter to enable angulations up to 60 degrees , atrial septostomy catheter • 4fr/5fr/6fr sizes , detachable balloon , vascular plugs- fda approved , vascular plugs- ce marked , vascular plugs- approved by dcgi , radiofrequency perforation accessories • compatible with beyliss system , group-d10 , pda coils made of steel • 0.035, 0.038 inches • sizes ranging from 2 x 2 to 15 x 15 , pda coils made of nitinol • 0.035, 0.038 inches • sizes ranging from 2 x 2 to 15 x 15 , pda coils made of platinum • 0.035, 0.038 inches • sizes ranging from 2 x 2 to 15 x 15 , 0.052 inch pda coils made of nitinol • sizes ranging from 2 x 2 to 15 x 15 , 0.052 inch pda coils made of platinum • sizes ranging from 2 x 2 to 15 x 15 , embolisation coils (0.018 inch) • sizes ranging from 2 x 2 to 15 x 15 , embolisation coils (0.035 inch) • sizes ranging from 2 x 2 to 15 x 15 , embolisation coils (0.052 inch) • sizes ranging from 2 x 2 to 15 x 15 , park blade septectomy catheter , group-d11 , balloon expandable pulmonary artery and aortic stents – approved for pediatric/adult use • available in various sizes , self expanding pulmonary artery and aortic stents- • approved for pediatric/adult use • available in various sizes , hydrophilic diagnostic guide wire - radifocus (regular length, regular stiffness) • must be available in 0.025, 0.032, 0.035 and 0.038 inches size • should have superelastic alloy core • should have super flexible wire tip • should be available in straight and angled tip • should be between 120-150 cm long , hydrophilic diagnostic guide wire -‘radifocus’ (exchange length, regular stiffness) • must be available in 0.025, 0.032, 0.035 and 0.038 inches size • should have superelastic alloy core • should have super flexible wire tip • should be available in straight and angled tip • should be 260 cm long , hydrophilic diagnostic guide wire - radifocus (regular length, extra-stiff) • must be available in 0.025, 0.032, 0.035 and 0.038 inches size • should have superelastic alloy core • should have super flexible wire tip • should be available in straight and angled tip o should be between 120-150 cm long , hydrophilic diagnostic guide wire - radifocus (exchange length, extra-stiff) • must be available in 0.025, 0.032, 0.035 and 0.038 inches size • should have superelastic alloy core • should have super flexible wire tip • should be available in straight and angled tip • should be 260 cm long , exchange length 0.035 inch guidewire dedicated for vsd device closure– noodle type , special introducer sheath for transseptal puncture • should include a dilator and sheath • dilator should provide smooth transition with septal puncture needle • should be available in varying sizes • radio-opaque tip marker for precise visualization of sheath • should be kink and collapse resistant • should be flexible , special long sheath with side arm having hausdorf-lock curve for asd device closure • variable lengths and sizes , special long sheaths with side arm having mullins curve, balkans curve, 180 curve and other curves • variable lengths and sizes , ptca inflation device- (maximum pressure upto 10 atm) • luminescent analog pressure gauge with maximum pressure up to 10 atm • efficient locking system to maintain high pressure • rapid inflation and deflation • clear barrel for easy visualization of de-bubbling • ergomatric and user friendly hand held design , group e -12 , disposable radiation protection pad -radial single layer, sterilized packed, non-vinyl, lead (pb)-free and light weight absorbable radial drape for protection from scattered radiation during interventional procedures like radial angioplasty, peripheral & ir etc. should have barc test certificate, and lead equivalency must be at least 0.125mmpb and attenuation shield size: 406mmx305mm mandatory document need to be submitted: • third-party environmental safety document. • clinical proof of attenuation. disposable radiation protection pad -femoral and subclavian single layer, sterilized packed, non-vinyl, lead (pb) -free and light weight absorbable femoral drape for protection from scattered radiation during interventional procedures like ep ablation, cto etc. should have barc test certificate, and lead equivalency must be at least 0.125mmpb and attenuation shield size: 406mmx305mm mandatory document need to be submitted: • third-party environmental safety document. • clinical proof of attenuation. no brainer cap non-lead single layer head cover, non-vinyl, lead (pb) -free x-ray attenuation, light weight surgical cap for radiation safety in all fluoro labs and must be fit all head sizes. should have a lead equivalency must be at least 0.125mmpb. weight should not be more than 95grams and attenuation shield size: 559mmx76mm mandatory document need to be submitted: • third-party environmental safety document. • clinical proof of attenuation , group -f1 , hydrophilic dignostic guide wire - (regular length, regular stiffness) • should be available in 0.025, 0.032, 0.035 and 0.038 inches size • should be available in straight and angled tip • should be between 120-180 cm long • short floppy tip 3-8 cm long , hydrophilic diagnostic guide wire - (exchange length, regular stiffness) • should be available in 0.025, 0.032, 0.035 and 0.038 inches size • should be available in straight and angled tip • should be 260 cm long • short floppy tip 3-8 cm long , hydrophilic diagnostic guide wire - (exchange length, regular stiffness) • should be available in 0.025, 0.032, 0.035 and 0.038 inches size • should be available in straight and angled tip • should be 300 cm long • short floppy tip 3-5 cm long , hydrophilic diagnostic guide wire - (regular length, extra-stiff) - • should be available in 0.025, 0.032, 0.035 and 0.038 inches size • should be available in straight and angled tip • should be between 120-180 cm long • short floppy tip 3-8 cm long , hydrophilic diagnostic guide wire - (exchange length, extra-stiff) • should be available in 0.025, 0.032, 0.035 and 0.038 inches size • should be available in straight and angled tip • 3-5 cm long tip • should be 260 cm long , hydrophilic diagnostic guide wire - (exchange length, extra-stiff) • should be available in 0.025, 0.032, 0.035 and 0.038 inches size • should be available in straight and angled tip • 3-5 cm long tip • should be 300 cm long , ptfe coated extrastiff shaft strength wire- backup meier( regular length) • extremely stiff stainless steel shaft core • flexible short length ‘j’ shaped tip which should be highly radio-opaque . • 0.035 inches • 185 cm long , ptfe coated extra stiff shaft strength exchange wire- backup meier (exchange length) • extremely stiff stainless steel shaft core • flexible short length ‘c’ shaped tip which should be highly radio-opaque . • 0.035 inches • 300 cm long , nitinol 0.014 inch guidewire (exchange length)straight and angled • with hydrophilic coating • 260-300 cm long • with and without flexible tip , nitinol 0.018 inch guidewire (exchange length) • straight and angled • with hydrophilic coating • 260-300 cm long • with and without flexible tip , group -f 2 , heavy duty nitinol alloy extra support wire ( regular length) • 0.014 inches • nitinol alloy • with angled tip-3-5 cm long • tip with platinum/platinum alloy for optimum visualisation • with tfe coating • 180 cm long , heavy duty nitinol alloy extra support wire (exchange length) • 0.014 inches • nitinol alloy • with angled tip-3-5 cm long • tip with platinum/platinum alloy for optimum visualisation • with tfe coating • 270-300 cm long , heavy duty nitinol extra support wire( regular length) • 0.018 inches • nitinol alloy • with angled tip-3-5 cm long • tip with platinum/platinum alloy for optimum visualization • with tfe coating • 180 cm long , heavy duty nitinol extra support wire (exchange length) • 0.018 inches • nitinol alloy • with angled tip: 3-5 cm long • tip with platinum/platinum alloy for optimum visualisation • with tfe coating • 270-300 cm long , steerable high support .014 inch guidewire • ptfe/duraglide coated • distal radiopaque tip 3 cm long • straight and j curve • 180cm long , steerable high support .014 inch guide wire ( exchange) • ptfe/duraglide coated • distal radiopaque tip 3 cm long • straight and j curve • 260-300cm long , cobra catheter • 4french/5french/6french • 65-125 cm long • 021-038 compatible • in various standard curves . , sos omni catheter • 035-038 compatible • 80 cm long , tapered straight catheter • 4french/5french/6french • 70,100 cm long • .035 inch compatible , picard catheter • 4french/5french/6french • 035-038 compatible • in various standard lengths. , group -f3 , renal double curve catheter • in various standard lengths and curves , head hunter catheter • in various standard lengths and curves • 035-038 compatible • 100cm long , simmons/ sidewinder catheter • in various standard lengths and curves • 035-038 compatible • 100cm long , pre -shaped catheter for uterine artery embolisation • in various standard lengths and curves , vertebral catheter • in various standard lengths and curves , coeliac axis catheter • in various standard lengths and curves , shepherd’s hook catheter • in various standard lengths and curves , micro catheters (coiled stainless steel construction) • in various standard lengths and curves • 2-3.8f size • .010-.022 inch wire compatible • with radioopaque marker at tip , micro catheters (braided nitinol construction) • in various standard lengths and curves • 2-3.8f size • .010-.022 inch wire compatible • with radioopaque marker at tip , straight introducer sheath (standard length) with hydro philic introducer guide wire • sizes from 4french/5french/ 6 french/7 french/8frenc/9french • between 7-11 cm long • with 0.035 or 0.038 inch hydrophilic mini guide wire • with plastic cannula for arterial puncture , group -f4 , straight long introducer sheath with hydrophilic introducer guide wire • sizes from 4french/5french/ 6 french/7 french/8frenc/9french • 16 cm long • with 0.035 or 0.038 inch hydrophilic guide wire • with plastic cannula for arterial puncture , straight reinforced sheath with hydrophilic coating • sizes from 6french /7french /8frenc/9french/10french/11french • between 7-11 cm long • with 0.035 or 0.038 inch guide wire compatible • with radio-opaque tip , group -f5 , guiding catheter for peripheral vascular use – – should be braided with low friction inner layer - should have atraumatic soft tip - should be available in various tip shapes and curves for access to different parts of the peripheral vasculature, including renal double curve, cobra, multi-purpose and other shapes - should have od of 6f-8f available - should have the largest id for each od - should have lengths ranging from 55-90 cm , guiding catheter for peripheral vascular use – – should be braided with low friction inner layer - should have hydrophilic coating - should have atraumatic soft tip - should be available in various tip shapes and curves for access to different parts of the peripheral vasculature. - should have od of 6f-10f available - should have the largest id for each od - should have lengths ranging from 55-125 cm , guiding catheter for peripheral vascular use – – should be braided with low friction inner layer - should have hydrophilic coating - should have atraumatic soft tip - should be available in various tip shapes and curves for access to different parts of the peripheral vasculature. - should have od of 5f available with the largest od - should have a minimum length of 55 cm or more , long sheath for peripheral vascular access– - should be kink resistant with a reinforcement mechanism - should be low friction with inner coating to allow catheter manipulation - should have distal radio-opaque tip for enhanced visibility on fluoroscopy - should have smooth transition from dilator to sheath - should have a proximal hemostasis valve/provision for tuohyborst valve - should be color coded for size identification - should be available in various sizes of inner diameters and various lengths and have the largest id available , long sheath for carotid access – - should be kink resistant with a reinforcement mechanism - should be low friction with inner coating to allow catheter manipulation - should have distal radio-opaque tip for enhanced visibility on fluoroscopy - should have smooth transition from dilator to sheath - should have a proximal hemostasis valve/provision for tuohyborst valve - should be color coded for size identification - should be available in 4f-8f size with the largest id - should have a minimum length of 90 cm or more , long sheath for contra-lateral iliac/femoral access – - should be kink resistant with a reinforcement mechanism - should be low friction with inner coating to allow catheter manipulation - should have distal radio-opaque tip for enhanced visibility on fluoroscopy - should have smooth transition from dilator to sheath - should have a proximal hemostasis valve/provision for tuohyborst valve - should be color coded for size identification - should be available in 4f-9f size with the largest id - should have lengths ranging from 40- 110 cm , group -f6 , long sheath for renal access – - should be kink resistant - should be low friction with inner coating to allow catheter manipulation - should have distal radio-opaque tip for enhanced visibility on fluoroscopy - should have smooth transition from dilator to sheath - should have a proximal hemostasis valve/provision for tuohyborst valve - should be color coded for size identification - should be available in 5f-7f size with the largest id - should be at least 55 cm long , high pressure angioplasty balloon for peripheral vascular use – - should have rated burst pressure > 14 atmosphere - should have hydrophilic coating - should be available in various outer diameters and balloon lengths and various shaft lengths , high pressure angioplasty balloon for peripheral vascular use – - should have rated burst pressure > 14 atmosphere - should have hydrophilic coating - should be available in various outer diameters and balloon lengths , high pressure angioplasty balloon for peripheral vascular use – - should have rated burst pressure > 14 atmosphere - should have hydrophilic coating - should be available in various outer diameters and balloon lengths - should be available in various shaft lengths , high pressure angioplasty balloon for peripheral vascular use – - should have rated burst pressure > 14 atmosphere - should have hydrophilic coating - should be available in 4-10 mm (in 1 mm increments) and 12 mm diameters and 2-10 cm balloon length - should have a shaft size of 75-135 cm , high pressure angioplasty balloon for peripheral vascular use– - should have rated burst pressure > 14 atmosphere - should have hydrophilic coating - should be available in 4-12 mm diameter and 2-10 cm balloon length - should have a shaft size of 75-135 cm , high pressure angioplasty balloon for peripheral vascular use– - should have rated burst pressure > 14 atmosphere - should have hydrophilic coating - should be available in 4-12 mm diameter and 2-10 cm balloon length - should have a shaft size of 75-135 cm , peripheral balloon catheter – - should be 0.035” compatible - should be over the wire - should have a burst pressure of at least 10 atmosphere (at least 6 atmosphere for larger balloons) - should have hydrophilic coating - should be available in various sizes of od and balloon lengths - should be available in various shaft lengths , peripheral balloon catheter – - should be 0.035” compatible - should be over the wire - should be non-compliant or semi-compliant - should have hydrophilic coating - should be available in all ods of 3-10 mm and 12 mm and balloon length of 2-10 cm. - should have burst pressure of at least 10 atmosphere (the 12 mm od balloon should have a burst pressureof at least 6 atmosphere) - should pass through a maximum 6f sheath (the 12 mm od balloon should pass through a maximum 7fsheath) - should have a shaft length 80-135 cm , group -f7 , peripheral balloon catheter – - should be 0.035” compatible - should be over the wire - should have a burst pressure of at least 10 atmosphere (at least 6 atmosphere for larger balloons) - should have hydrophilic coating - should be available in various sizes of od and balloon lengths - should be available in various shaft lengths , peripheral balloon catheter – - should be 0.035” compatible - should be over the wire - should be non-compliant or semi-compliant - should have hydrophilic coating - should be available in od of 3-10 mm and 12 mm and balloon length of 2-10 cm. - should have burst pressure of at least 10 atmosphere (the 12 mm od balloon should have a burst pressureof at least 6 atmosphere) - should pass through a maximum 6f sheath (the 12 mm od balloon should pass through a maximum 7fsheath) - should have a shaft length 80-135 cm , peripheral balloon catheter – - should be 0.035” compatible - should be over the wire - should have a burst pressure of at least 10 atmosphere (at least 6 atmosphere for larger balloons) - should have hydrophilic coating - should be available in various sizes of od and balloon lengths - should be available in various shaft lengths , peripheral balloon catheter – - should be 0.035” compatible - should be over the wire - should be non-compliant or semi-compliant - should have hydrophilic coating - should be available in all ods of 3-10 mm and 12 mm and balloon length of 2-10 cm. - should have burst pressure of at least 10 atmosphere (the 12 mm od balloon should have a burst pressureof at least 6 atmosphere) - should pass through a maximum 6f sheath (the 12 mm od balloon should pass through a maximum 7fsheath) - should have a shaft length 80-135 cm , peripheral balloon catheter with large diameter - should be 035” compatible - should be over the wire - should have hydrophilic coating - should have od of 14 mm and more - various lengths of the balloon should be available - should be mounted on various shaft lengths , peripheral balloon catheter with large diameter – - should be 035” compatible - should be over the wire - should have hydrophilic coating - should an od of at least 14 mm - various lengths of the balloon should be available - should be mounted on various shaft lengths , peripheral balloon catheter with large diameter – - should be 035” compatible - should be over the wire - should have hydrophilic coating - should an od of at least 14 mm - various lengths of the balloon should be available - should be mounted on various shaft lengths , peripheral balloon catheter – - should be .014/.018” compatible - should be over the wire - should have hydrophilic coating - should be available in various balloon diameters - should be available in various lengths of the balloon - should be available in various shaft lengths , group -f9 , peripheral compliant balloon with large diameter – - should be .035” compatible - should have od ranging from 10-46 mm - should have shaft length >90 cm - should have shaft of not more than 8f size - should pass through a 12f sheath , peripheral stent balloon mounted – - should be .014/.018” compatible - should be over the wire - should be made of stainless steel alloy - should have balloon od in the range of 4-7 mm - should have balloon/stent lengths in the range of 12-25 mm - should have shaft lengths of 80-150 cm , peripheral stent balloon expandable – - should be .014/.018” compatible - should be over the wire - should be made of stainless steel alloy - should have balloon od in the range of 4-7 mm - should have balloon/stent lengths in the range of 12-25 mm - should have shaft lengths of 80-150 cm , group -f10 , peripheral stent balloon expandable - - should be .014/.018” compatible - should be for rapid exchange - should be made of stainless steel alloy - should have balloon od in the range of 4-7 mm - should have balloon/stent lengths in the range of 12-25 mm - should have shaft lengths of 80-150 cm , peripheral stent balloon expandable – - should be 035” compatible - should be made of stainless steel or cobalt chromium - should be quoted either in open cell or closed cell design - should be available in various balloon ods - should have various balloon/stent lengths available - should have a shaft length of 75-135 cm , peripheral stent balloon mounted – - should be 035” compatible - should be made of stainless steel or cobalt chromium - should be quoted either in open cell or closed cell design - should be available in various balloon ods - should have various balloon/stent lengths available - should have a shaft length of 75-135 cm , peripheral stent balloon expandable – - should be .035” compatible - should be made of stainless steel or cobalt chromium - should be quoted either in open cell or closed cell design - should be available in various balloon ods - should have various balloon/stent lengths available - should have a shaft length of 75-135 cm , peripheral stent balloon expandable – - should be .035” compatible - should be made of stainless steel - should have a tandem architecture design - should have all balloon ods from 5-10 mm in 1 mm increments - should have available various balloon/stent lengths of 20 to 55mm - should have a shaft length of 75 -135 cm , peripheral stent balloon expandable – - should be .035” compatible - should be made of stainless steel - should have a tandem architecture design - should have all balloon ods from 5-10 mm in 1 mm increments - should have available various balloon/stent lengths from 20 to 55 mm - should have a shaft length of 75 -135 cm , peripheral stent balloon expandable - should be .035” compatible - should be made of stainless steel - should have a tandem architecture design - should have all balloon ods from 5-10 mm in 1 mm increments - should have available various balloon/stent lengths from 20 to 55 mm - should have a shaft length of 75 -135 cm , peripheral stent balloon expandable – - should be .035” compatible - should be made of stainless steel - should be laser cut slotted tube with closed cell design - should have balloon ods from 5-25 mm, bare or balloon mounted - should have available various balloon stent/lengths from 2-6 cm - should have a shaft length of up to 135 cm , peripheral stent balloon expandable – - should be .035” compatible - should be made of stainless steel - should be laser cut slotted tube with closed cell design - should have balloon ods from 5-25 mm, bare or balloon mounted - should have available various balloon stent/lengths from 2-6 cm - should have a shaft length of up to 135 cm , peripheral stent balloon expandable – - should be .035” compatible - should be made of stainless steel - should be laser cut slotted tube with closed cell design - should have balloon ods from 5-25 mm, bare or balloon mounted - should have available various balloon stent/lengths from 2-6 cm - should have a shaft length of up to 135 cm , group- f11 , self-expanding peripheral stent – - should be .014/018” compatible - should be over the wire - should be made of nitinol - should have the least lesion crossing profile for all stent diameters - should be available in various stent diameters of 6-10 mm - should be available in various stent lengths from 20-40 mm - should have a shaft length of at least 110 cm , self-expanding peripheral stent – - should be .014/.018” compatible - should be over the wire - should be made of nitinol - should have the least lesion crossing profile for all stent diameters - should be available in various stent diameters of 6-10 mm - should be available in various stent lengths from 20-40 mm - should have a shaft length of at least 110 cm , self-expanding peripheral stent – - should be .014/.018” compatible - should be over the wire - should be made of nitinol - should have the least lesion crossing profile for all stent diameters - should be available in various stent diameters of 6-10 mm - should be available in various stent lengths from 20-40 mm - should have a shaft length of at least 110 cm , self-expanding peripheral stent – - should be .014/.018” compatible - should be over the wire - should be laser cut open cell nitinol tube - should have a low lesion crossing profile - should be available in all stent diameters of 6-10 mm - should be available in stent lengths of 2-6 cm - should be on a shaft length of 110-140 cm , self-expanding peripheral stent – - should be .014/.018” compatible - should be over the wire - should be laser cut open cell nitinol tube - should have a low lesion crossing profile - should be available in all stent diameters of 6-10 mm - should be available in stent lengths of 2-6 cm - should be on a shaft length of 110-140 cm , self-expanding peripheral stent – - should be .014/.018” compatible - should be over the wire - should be laser cut open cell nitinol tube - should have a low lesion crossing profile - should be available in all stent diameters of 6-10 mm - should be available in stent lengths of 2-6 cm - should be on a shaft length of 110-140 cm , self expanding peripheral stent – - should be .014/.018” compatible - should be of rapid exchange type - should be made of nitinol - should be available in stent lengths of 3-4 cm - should have a minimum shaft length of 110 cm , self expanding peripheral stent – - should be .014/.018” compatible - should be of rapid exchange type - should be made of nitinol - should be available in stent lengths of 3-4 cm - should have a minimum shaft length of 110 cm , self expanding peripheral stent – - should be .014/.018” compatible - should be of rapid exchange type - should be made of nitinol - should be available in stent lengths of 3-4 cm - should have a minimum shaft length of 110 cm , self-expanding peripheral stent – - should be .035” compatible - should be over the wire - should be made of nitinol - should be available in various outer diameters - should be of various stent lengths - should be on a shaft length of 80-140 cm , group -f12 , self-expanding peripheral stent – - should be .035” compatible - should be over the wire - should be made of nitinol - should be available in various outer diameters - should be of various stent lengths - should be on a shaft length of 80-140 cm , self-expanding peripheral stent – - should be .035” compatible - should be over the wire - should be made of nitinol - should be available in various outer diameters - should be of various stent lengths - should be on a shaft length of 80-140 cm , self-expanding peripheral stent – - should be .035” compatible - should be over the wire - should be laser cut from single nitinol tube with no welds - should be available in outer diameters of 5-14 mm - should be available in stent lengths of 2-15 cm - should be on a shaft length of 80-140 cm - should be available in various lengths of 20-100 mm , peripheral bio-degradable or absorbable metal stent - should be balloon mounted or self-expanding type - should be available in outer diameters of 4-8 mm - should be available in various lengths of 20-100 mm , group -f13 , dedicated peripheral vascular bifurcation stent - should be balloon mounted - should be available in different diameters and lengths of the stent , self expanding peripheral covered stents – - should be .035” compatible - should be over the wire - should be made of nitinol with fabric coating - should be available in various outer diameters - should be available in various stent lengths - should be on a shaft length of 80-140 cm. , self expanding peripheral covered stents – - should be .035” compatible - should be over the wire - should be made of nitinol with fabric coating - should be available in various outer diameters - should be available in various stent lengths - should be on a shaft length of 80-140 cm , self expanding peripheral covered stents – - should be .035” compatible - should be over the wire - should be made of nitinol with fabric coating - should be available in various outer diameters - should be available in various stent lengths - should be on a shaft length of 80-140 cm. , self expanding peripheral covered stents – - should be .035” compatible - should be over the wire - should be made of nitinol with ptfe coating on the inner lumen - should be available in outer diameters of 5-13 mm - should be avaiable in stent lengths of 2-15 cm - should be on a shaft length of 75-140 cm. , self expanding peripheral covered stents – - should be .035” compatible - should be over the wire - should be made of nitinol with ptfe coating on the inner lumen - should be available in outer diameters of 5-13 mm - should be avaiable in stent lengths of 2-15 cm - should be on a shaft length of 75-140 cm. , self expanding peripheral covered stents - should be .035” compatible - should be over the wire - should be made of nitinol with ptfe coating on the inner lumen - should be available in outer diameters of 5-13 mm - should be avaiable in stent lengths of 2-15 cm - should be on a shaft length of 75-140 cm. , covered stent for transjugular intrahepatic porto-systemic shunt - should be .035/038” compatible - should be made of nitinol with fabric coating - should be with or without a distal uncovered portion - should be available in various outer diameters and stent lengths - should be compatible with the quoted tips set , covered stent for transjugular intrahepatic porto-systemic shunt - should be .035/038” compatible - should be made of nitinol with ptfe coating on inner lumen - should be with a distal at least 2 cm uncovered portion - should be available in all outer diameters of 8,10,12 mm - should be available in all stent lengths of 4,5,6,7,8 cm - the delivery system should be at least 75 cm long - should be compatible with the quoted tips set , embolisation coils - should be .014/018” compatible - should be made of platinum with synthetic fibres - should be non tapering/straight - should be mr compatible - should be available in any or more of the following diameters: 2-10 mm - should be of various lengths; the length of the coil at each diameter should be stated , group- f14 , embolisation coils -should be .014/018” compatible - should be made of platinum with synthetic fibres - should be mr compatible - should taper from a larger to a smaller end - should be available in any or more of the following diameters: 3-10 mm - the diameter to tapered end for tapering type coils should be stated - should be of various lengths; the length of the coil at each diameter should be stated , embolisation coils - should be .035/038” compatible - should be non tapering/straight - should be made of platinum with synthetic fibres - should be mr compatible - should be available in the following sizes: diameter 3-15 mm and length 2-15 cm , embolisation coils - should be .035/038” compatible - should be made of platinum with synthetic fibres - should be mr compatible - should be tapering from a larger to a smaller end - should be available in following sizes: diameter 5-10 mm and length 2-15 cm - the diameter to tapered end for tapering type coils should be mentioned , embolisation coils - should be .035/038/052” compatible - should be non tapering/straight - should be made of stainless steel with synthetic fibres - should be available in the following sizes: diameter 3-15 mm and length 2-15 cm , coil pusher wire for 0.014/0.018” coils, compatible with the quoted microcatheters , polyvinyl alcohol particles for peripheral vascular embolization - should be of non-uniform size - should undergo rapid clumping in the vessels - should cause non-uniform vessel occlusion - should be available in a broad range of sizes (90 microns- 1400 microns) , microspheres for peripheral vascular embolization - should be hydrophilic - should be micro-porous and uniform sized spheres - should be non-aggregating - should be deformable for ease of passage through smaller vessels - the size of spheres should range from40-1200 micrometers , gelfoam sheet for vascular embolization , non-adhesive liquid polymer for controlled embolization - should be ethylene vinyl copolymer in dimethylsulfoxide solution - should be supplied in various concentrations for use depending on lesion morphology , adhesive liquid polymer for vascular embolization - should be n-butyl cyanoacrylate , group -f15 , tantalum powder -should be useful for improved visualization during n-butyl cyanoacrylate embolization - should be supplied as finely ground powder , lipiodol - the material should be iodised oil, containing ethyl esters of iodized fatty acids of poppy seed oil - the iodine content should be a minimum of 480 mg/ml - should useful as opacifying agent for n-butyl cyanoacrylate on fluoroscopy and an organic diluent for thisagent - should be supplied in 10 ml ampoules , sclerosant for intravenous embolization - the compound should be sodium tetradecyl sulfate - should be available in various concentrations for use depending on lesion type , sclerosant for intravenous embolization - the compound should be aetoxisclerol - should be available in various concentrations for use depending on lesion type , medical grade ethanolamine oleate for vascular embolization , detachable balloon for embolization - detachable balloons with radioopaque marker with and without self-sealing valve - 0.1 cc – 3 cc or more in capacity - please specify the make and capacity of the balloons (latex/silicon). - the catheter shaft should be of at least 120 cm in length , transjugular liver biopsy set - should include angled tip needle advanced through percutaneously introduced liver access set - should have a firing spring mechanism - needle gauge should be available in 18 and 19g and needle length should be 45-60 cm - the needle throw distance should be not more than 2 cm - should include the check-flo valve adapter, stiffening cannula curved and straight catheter and introducer sheath (upto 7f size) , transjugular intrahepatic porto-systemic shunt access set - should include a micropuncture introducer set -should include an introducer sheath that should be no more than 10f size, at least 38 cm long and 035/038”compatible - the sheath should provide maximum flexibility without getting kinked - the sheath should have proximal check flo mechanism - the sheath should have distal radiopaque tip to indicate sheath tip on fluoroscopy - the set should also include a needle of 16g and at least 50 cm long with angled tip to facilitate directiontowards portal vein - there should be a curved/angled catheter, a straight catheter and a centimeter sizing catheter incorporated in the set for the various steps of the procedure , transjugular liver access set (10f) for various diagnostic and interventional liver procedures - should include a 10f and at least 38 cm long introducer sheath - should include a stiffening cannula of at least 14 gauge and length of at least 51 cm - should include a trochar with stylet that is 035/038” compatible and at least 60 cm long , transjugular liver access set (7-9f) for various diagnostic and interventional liver procedures - should include a 7f or 9f introducer sheath that is at least 38 cm long - should include needle with angled tip that is 16f (for 9f) and 18g (for 7f) sheath - should be 035/038” compatible - the needle shoud be at least 50 cm long , group -f16 , ivc filter - for optimal filtration of ivc diameter of upto 40 mm - made of either nitinol or stainless steel - catheter carrier system inner diameter should be of maximum 12f - it should be possible to insert from either jugular or femoral access - should be for permanent use , ivc filter - for optimal filtration of ivc diameter of upto 28 mm - made of nitinol and filter length to be upto 38 mm - catheter carrier system inner diameter should be of maximum 7f size - it should be for permanent use - it should be possible to place the filter from femoral/jugular/antecubital access , ivc filter - for optimal filtration of ivc diameter of upto 28 mm - made of nitinol and filter length to be upto 55 mm - catheter carrier system inner diameter should be of maximum 10 f size - it should be for optional (permanent or retrievable) use - it should be possible to place the filter from femoral/jugular/antecubital access , ivc filter - for optimal filtration of ivc diameter of upto 30 mm - made of conichrome material and filter length not more than 50 mm - should be able to be placed either through jugular or femoral approach - should be for optional (permanent or temporary) use , percutaneous mechanical thrombectomy catheter - should allow treatment of fresh and older thrombotic occlusions of peripheral arteries - should combines mechanical fragmentation and aspiration alongwith transport of debris outside thevascular system - should be available in both antegrade or cross-over configurations - for antegrade access – maximum shaft size should be 6f - for cross-over access – maximum shaft size should be 8f , urokinase for intra-arterial thrombolysis , tissue plasminogen activator for intra-arterial thrombolysis , infusion catheter - should have multiple side ports - should provide an infusion length of 5-15 cm - should have a catheter tip occluder - should have attachment for tuohy-borst side arm adapter - should have a maximum od of 5f - should be compatible with 035/038” wire - should have a shaft length of 60-100 cm , distal embolic protection device - should be on a .014” wire - should be made of nitinol material - should not occlude flow while in placement - should completely cover the vessel circumference at the desired placement site to afford complete protection - should have the least lesion crossing profile - should be available in various sizes for adapting to the vessel size , distal embolic protection device - should be on a .014” wire - should be made of nitinol material - should not occlude flow while in placement - should be rapid exchange type - should allow use of a separate .014/018” wire for initial crossing of the lesion - should be compatible with a 6f guiding catheter (0.066” id) - should allow longitudinal wire movement with filter remaining in place - should be available in 3-7 mm sizes , group -f17 , endovascular stent graft device for treatment of thoracic aortic aneurysms and dissections - device should be with proximal barbs, with or without distal bare spring configuration, and should beeither tapered or non-tapered. - the aortic device should be available in any one or more of the following sizes: od 26-44 mm; length 4-24 cm. the device should be able to be advanced on upto 24f shaft size. - the manufacturer should agree to supply the size customized to the patient’s anatomy based on ctangiography , endovascular stent graft device for treatment of thoracic aortic aneurysms and dissections - device should be without proximal barbs, without distal bare spring configuration, and should be eithertapered or non-tapered. - the aortic device should be available in any one or more of the following sizes: od 26-44 mm; length 4-24 cm. the device should be able to be advanced on upto 24f shaft size. - the manufacturer should agree to supply the size customized to the patient’s anatomy based on ct angiography , endovascular stent graft device for treatment of thoracic aortic aneurysms and dissection - device should be without proximal barbs, with distal and/or proximal bare spring configurations, andshould be non-tapered. - the aortic device should be available in any one or more of the following sizes: od 26-44 mm; length 4-24 cm. the device should be able to be advanced on up to 24f shaft size. - the manufacturer should agree to supply the size customized to the patient’s anatomy based on ct angiography , endovascular stent graft device for treatment of thoracic aortic aneurysms and dissection - device should be without proximal barbs, with distal and/or proximal bare spring configurations, andshould be tapered. - the aortic device should be available in any one or more of the following sizes: od 12-44 mm; length 4-24 cm. the device should be able to be advanced on upto 24f shaft size. - the manufacturer should agree to supply the size customized to the patient’s anatomy based on ct angiography , endovascular stent graft device for treatment of abdominal aortic aneurysms - device should be with or without proximal barbs, with or without distal bare spring configuration, andshould be either tapered or non-tapered. - devices with or without transrenal or suprarenal fixation should be quoted. - the aortic device should be available in any one or more of the following sizes: od 12-44 mm; length 4-24 cm. the device should be able to be advanced on aupto 24f shaft size. - the limb extensions of the main device for abdominal aortic applications should be available in 12-22 mmdiameter, with or without flared ends and upto 12 cm in length - the manufacturer should agree to supply the size customized to the patient’s anatomy based on ctangiography , endovascular stent graft device for treatment of abdominal aortic aneurysms - device should be with proximal barbs, with or without distal bare spring configuration, and should beeither tapered or non-tapered. - devices with transrenal or suprarenal fixation should be quoted. - the aortic device should be available in any one or more of the following sizes: od 12-44 mm; length 4-24 cm. the device should be able to be advanced on aupto 24f shaft size. - the limb extensions of the main device for abdominal aortic applications should be available in 12-22 mmdiameter, with or without flared ends and upto 12 cm in length - the manufacturer should agree to supply the size customized to the patient’s anatomy based on ctangiography , endovascular stent graft device for treatment of abdominal aortic aneurysms - device should be without proximal barbs, with or without distal bare spring configuration, and should beeither tapered or non-tapered. - devices with transrenal or suprarenal fixation should be quoted. - the aortic device should be available in any one or more of the following sizes: od 12-44 mm; length 4-24 cm. the device should be able to be advanced on aupto 24f shaft size. - the limb extensions of the main device for abdominal aortic applications should be available in 12-22 mmdiameter, with or without flared ends and upto 12 cm in length -the manufacturer should agree to supply the size customized to the patient’s anatomy based on ct angiography , endovascular stent graft device for treatment of abdominal aortic aneurysms - device should be without proximal barbs, with or without distal bare spring configuration, and should beeither tapered or non-tapered. - devices without transrenal fixation should be quoted. - the aortic device should be available in any one or more of the following sizes: od 12-44 mm; length 4-24 cm. the device should be able to be advanced on aupto 24f shaft size. - the limb extensions of the main device for abdominal aortic applications should be available in 12-22 mmdiameter, with or without flared ends and upto 12 cm in length - the manufacturer should agree to supply the size customized to the patient’s anatomy based on ctangiography covered stent-graft (extender or iliac or contralateral limb) in diameters ranging from 12-22 mm and lengths ranging from 30-110 mm for over-the-wire delivery , peripheral vascular catheter for excision of artheroma- should have high rotation speed of the cutting mechanism without causing any trauma to the vessel – , group -g1 , permanent pacemakers with all leads and accessories • ssir, • all single chamber modes and basic pacing programmable parameters. • must have ventricular capture management • the size of lead must be 7 f or less. • the lead must be steroid eluting and should be both bipolar and unipolar configuration. • must have both active and passive fixation endocardial leads available. • life term replacement warranty • direct presence of parent company in india (not only through the distributors) and company mustprovide its trained technical person for each implantation when ever required and for follow upprogramming when it is required. • company must provide at least one programmer exclusively to the cardiology department. • company must quote only the latest model of devices commercially available department. , group -h1 -temporary pacing leads , temporary pacing leads (fda approved) , temporary pacing leads (ce approved) , temporary pacing leads (dcgi approved) , temporary pacing lead: woven interweaved, braided , temporary pacing leads: balloon floatable , bipolar catheter with central lumen038 wire compatible, variable length. , screw - in bipolar temporary pacing lead = 65 cm , temporary lead for internal cardio version , group -h1 -a long sheaths /introducers , long sheaths /introducers-prefaced valved long sheaths for rfa with mullins curve, multipurpose curve, other curves, 7f to 9f, at least 80- cm long, 0.038 wire compatible , long sheaths /introducers-bidirectonal, steerable long sheaths with variablereach, autolock , long sheaths /introducers-brite tip intervention sheath with tip visualization, kink resistant, cold shape able with silicon coating , long sheaths /introducers-introducer sheaths for electrophysiology, with various swartz curves sl 0-4, sr 0-4, 8f, 8.5f,9f , long sheaths /introducers-long sheaths (peel away, slit table, with breakable valve) for special applications like coronary sinus intubation, lateral vein. special curves like renal, hook shape etc , long sheaths /introducers-peel away introducer sheaths with break away hemostatic valves for pacing leads, 5f-12f, 10 cm – 30 cm, optional infusion side port, radio opaque edistal tip and multiple curves , long sheaths /introducers-multiport catheter introducer sheaths , long sheaths /introducers-pacing lead stabilizers , long sheaths /introducers-3-d braided steerable guiding introducer sheath, supporting transseptal crossing, atrial ablation procedures, with one device delivery system having all 8 steering curves (sl and sr), can accommodate multiple sheath sizes , group -h2 (diagnostic ep catheters) the vendor should quote for each catheter separately if prices differ based upon french size, curve,electrode catheter design (electrode size, electrode distance, electrode material) etc. it will be easier if the common catheters used like 6f, josephson curve, electrode configuration 2-5-2-5, stainless steelelectrodes/platinum electrodes are specified first. all cables should be quoted separately. cost mentioned for each item will be compared based on the catheter and cable. must be compatible to st jude ensite precision , quadripolar 6, any , quadripolar 5-7, mullins , quadripolar 5-7, josephson , quadripolar 5-7, his bundle , quadripolar 5-7 4-2, mullins , quadripolar 6, mullins , tripolar 5-7, any , tripolar 6, josephson , hexapolar 6, any , decapolar 5-7, any , decapolar 6, any , decapolar 5-7, any, 2-5-2 , decapolar 5-7, any, 2-2-2 , decapolar 5-7, any, 2-2-2-10-2-2-2-10-2 , ep cathters for pediatric ep work -quadripolar 4 2-5-2- , ep cathters for pediatric ep work -quadripolar 4 , ep cathters for pediatric ep work -decapolar 4 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) - , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -quadripolar 6 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -quadripolar 5-7 2-5 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -quadripolar 5 -7 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -quadripolar5 -7 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -hexapolar 6 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -decapolar 6 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -decapolar 5 -7 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -decapolar 5 -7 , woven ep diagnostic catheters (woven material with braided conducting wire, ensuring prolonged stability) -decapolar 5 -7 , woven pediatric ep catheters (woven material with braided conducting wire, ensuring prolonged stability) - , woven pediatric ep catheters (woven material with braided conducting wire, ensuring prolonged stability) -quadripolar 4 , woven pediatric ep catheters (woven material with braided conducting wire, ensuring prolonged stability) -quadripolar 4 , woven pediatric ep catheters (woven material with braided conducting wire, ensuring prolonged stability) -decapolar 4 , group –h3 [special catheters for af, flutter, etc(quote all diameters, french size, different electrodes like platinum or stainless steel)] , deflect decaduapolar (20 poles) for a flutter----all diameters , deflectable decapolar (10)(pulm. vein)---all diameters , deflectable decaduapolar (20) (pulm. vein)—all diameters , 2f multipolar (> ten electrodes) for mapping through coronary vasculature , basket catheter with accessory , crista catheter with accessories , other special ep catheters , pacing catheter with angiographic capability • variable sizes • bipolar or quadripolar with appropriate cable • cvp monitoring & angiographic facility , paediatric use: all the above catheters, sheaths, etc, for paediatric use - implying smaller french size like 4f,5f, with certification for use in children , group -h4 (ablation catheters) - (all sizes 4f to 8.5f, all curves a-k, 270, all electrode sizes and spacing, eg.) (all items differing in make/prices need to be mentioned separately. quote separately if different in terms of material, braiding, electrode material platinum or stainless steel etc) quote with appropriate connector to existing ept 1000 and stockert ablators. ept 1000 is not compatible with thermocouple and appropriate catheters/ connectors should be quoted. thermistor catheters would therefore by preferred. in addition give prices of all connector cables /accessories separately. , regular 4mm all , regular 8mm , regular 3.5mm all , regular 8mm , regular 4mm , cool tip (closed) any , irrigated tip (open) any , others any , bidirectional any , omnidirexnl any , group -h5 (catheters, cables, accessories, for carto system and thermocool infusion pump) , navistar catheters regular , navistar catheter irrigated tip , location patch carto system (refstar) , connecting cables for all catheters , access/tubings for cool flow pump and any other accessories , group -h5-a catheters, cables, accessories for endocardial solutions (esi) accessories , navex patches , balloon array , other accessories (quote each separately) , catheters/accessories for loca lisa , reusable defibrillation/transcutaneous pacing patches (suitable for equipment in cath lab, ct2, ct3, ct6) , disposable defibrillation/transcutaneous pacing patches (suitable for equipment in cath lab, ct2, ct3, ct6) , defibrillation/transcutaneous pacing patches for use in infants and children , cryo catheters (and accessories) for ablation of arrhythmias in children and adults , intra cardiac ultrasound/echo catheter for guiding rfa compatible with the existing echo machine at neigrihms (quote all prices of the catheters and accessories) , disposable electrocautery patches for rfa (suitable for stockert and ept 1000 ablators) reusable electrocautery patches for rfa (suitable for stockert and ept 1000 ablators) electrocautery pencils for use in dissection , electrocautery pencils for use in dissection , group -h6 (pacemaker lead extraction systems -mention each system price and also individual accessories) , laser guided lead extraction system with accessories (fda/ce certified) , rf guided lead extraction system with accessories (fda/ce certified) , other extraction systems (fda/ce approved) , accessories for lead extraction like locking stylet, other accessories , intracardiac echocardiographic (ice) catheter , lead locking device for lead extraction with sizing from 0.38mm to 0.58mm compatible with any make &all range of leads, with radiopaque marker at the tip, and a proximal connector and mandrel to deploy the device. , mechanical dilator sheath, with bi-directional rotating 574 degree, while extending the blade just 0.02 inches, with flexible shaft and a static outer shaft. , otherspecific items for advanced cardiac procedure , balloon - expanding type of tavi (transcatheter aortic valve implantation) with all standard accessories for implantation different sizes.available sizes:20mm,21.5mm,23mm,24.5mm,26mm,27.5mm,29mm,30.5mm,32mm , sirolimus eluting bioresorbable coronary vascular scaffold system having various diamter and length of upto 40mm , coronary intravascular lithotripsy catheter system with foot peddel . sizes available 2.5mm, 2.75 mm ,3.0mm,3.5mm& 4.0mmand length 12mm , ptca balloon (semi-compliant) - • monorail (rapid exchange) and over-the-wire (otw) balloons • available in all sizes and lengths
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • 4
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : tube inner
  • Gear Tube Tenders ,
  • Steel Tube Tenders ,
  • Heat Shrinkable Tube Tenders ,
  • Longitudinal Tube Tenders ,
  • Stay Tube Tenders ,
  • Galvanized Tube Tenders ,
  • Spiral Tube Tenders ,
  • Cooler Tube Repair Tenders ,
  • Air Tube Tenders ,
  • Bakelite Tube Tenders

Get tube inner Tender Alert...

442492

Related Searched Keywords : tube inner

  • Irrigation Works Tenders From Maharashtra
  • False Celling Tenders From Delhi
  • Flood Gate Tenders From West-Bengal
  • Horizontal Boring Machine Tenders From -Tamil-Nadu
  • Construction Work Tenders From Andhra-Pradesh
  • Paver Work Tenders From Gujarat
  • Water Proof Tenders From Karnataka
  • Roofing Work Tenders From Uttar-Pradesh
  • Dismantlement Tenders From Rajasthan
  • Rcc Roofing Tenders From Madhya-Pradesh

Read More


Tender Document

275231

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Tile Works Tenders
  • Disilting Work Tenders
  • Culvert Slab Tenders
  • Granite Work Tenders
  • Check Dam Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App