Thank you for your interest to view the below mentioned tender. If you want to view further details, download available tender documents, require bidding support, class 3 digital signature certificate, signing and encryption, vendor registration support and much more, click Download Tender Document link.

Basic tender information about # 19088620

Rectification Of Piping, Cladding And Ahus Defects @ Gren 400 Kv Location : Gren 400 Kv Scope Of Works: -#Defective Gate Valves, 3 Way Motorized Valves In The Air Handling Units, Drvs In The Chiller Side, Defective Siphons, Pressure Gauges, Air Vents To Be Repl Aced In The Chilled Water Circuit. -#Leak Testing To Be Done After The Accessories Replacement. -#Defects Cladding To Be Replaced. - #Valves And Accessories Shall Be Of Same Make And Origin. Ahu No. 2 & 2A 2 Nos. Ahu No. 3 & 3A 2 Nos. Supply & Installation Of G Ate Valve 1 No. Each Ahu, 3-Way Motorized Valve 1 No. Each Ahu, Drv 1 No. Each Ahu, 2-Way Motorized Valve 1 No., Strainer 1 No., Siphons 1 No., Pressure Gauges 2 Nos., Air Vents 1 No., Rubber Insulation, Foster, Piping Cladding & Flexible Rubber F Lange. Carry Out Leak Test. Replacement Of Ahu Duct Cladding Ahu No. 1 & 1A 2 Nos. 1. Supply & Installation Of Gate Valve 1 No. Each Ahu, 3-Way Motorized Valve 1 No. Each Ahu, Drv No. Each Ahu, 2-Way Motorized Valve 1 No., Strainer 1 No., Siphons 1 No ., Pressure Gauges 2 Nos., Air Vents 1 No., Rubber Insulation, Foster, Piping Cladding & Flexible Rubber Flange. 2. Carry Out L Eak Test. 3. Replacement Of Ahu Duct Cladding Damaged Top Side Area Only. Note: Gate Valve, Drv Brand Is Motorized Brands And Mak E Shall Be As Per Site Condition. Notes:- A#Party To Visit The Site, To Assess The Entire Work To Be Carried Out And Then Quote F Or Lump Sum Accordingly. Contact Details For Arranging The Site Visit Are: Mr. Rashid Kallery Mob: 052-5507585/04-3221477 Or Mr. S Uresh 050-4611816/04-3221471 B Contractor To Submit Method Statement To Dewa-Tcm And To Obtain Approval Prior To Start The Work. C All Loading, Unloading And Shifting Of Compressors And Other Materials Are Under Scope Of The Contractor. D Upon Issue Of Po, Entry Permit Approval Ptw In Prescribed Format Shall Be Obtained By Contractor Prior To Start The Work In The Substation. E Con Tractor Shall Provide Minimum 2 Year Warranty For The Newly Supplied Materials And Workmanship From The Date Of Acceptance Of The Co Mpleted Work. F The Delivery Note For Newly Supplied Materials, Testing Report, Warranty Certificate, Work Completion Report Along With Po Copy Shall Be Submitted To Dewa-Tam After Successful Completion Of The Work. Contact Person For Documents Submission: Mr. A Zeem Ph: 04-3221689/ 055-7728480. Mr. Nizar Mohammed Koya Ph: 04-3221476/Mob: 055-9726046 Or G The Place Of Work Shall Be Ke Pt Clean At All Times Before, During And After The Work. Spillage And Splashes Shall Be Avoided; And If Spilled, Then It Shall Be Cl Eaned Immediately. H Contractor#S Staff Shall Wear Necessary Ppes Like Uniform, Safety Shoes And Helmet While On Work And Should Abide By The Dewa Safety Procedure, Rules & Regulations For The Safe Completion Of Job. -------------------------End---------------- -----------------

Download Document

Related Information

Location

Dubai - Dubai, United Arab Emirates

Tender No

2332001996

Tender Type

Contract

Important Dates

Published on

24 Sep, 2020

Submission Date

30 Sep, 2020

Opening Date

30 Sep, 2020

Key Values

Work Value

NA

EMD

NA

Document Fee

NA