Bidding Support

679602

Bidding Support

Warm Greetings from www.thetenders.com, the fastest growing tender information portal in India.

Supply of CONTROL VALVES - As per Sl. No. 1 of pg. 1 of tech spec i.e.ASV-8 -D A Pegging from Aux. Steam Header , As per Sl. No. 2 of pg. 1 of tech spec i.e.CRHV-6 -D A Pegging from CRH Line , As per Sl. No. 3 of pg. 1 of tech spec i.e.CDV-22 -Main Condensate Control - 1 , As per Sl. No. 4 of pg. 1 of tech spec i.e.CDV-25 -Main Condensate Control - 2 , As per Sl. No. 5 of pg. 1 of tech spec i.e.CDV-40 -GSC,CEP Min. flow recirculation , As per Sl. No. 6 of pg. 1 of tech spec i.e.CDV-46 -Excess Return to CST , As per Sl. No. 7 of pg. 1 of tech spec i.e.CDV-72 - Condensate for Valve Gland Sealing , As per Sl. No. 8 of pg. 1 of tech spec i.e.DRV-2 -HPH-9A Drain to HPH-8A , As per Sl. No. 9 of pg. 1 of tech spec i.e.DRV-8 -HPH-9B Drain to HPH-8B , As per Sl. No. 10 of pg. 1 of tech spec i.e.DRV-5 - HPH-9A Alt. Drain to F,T , As per Sl. No. 11 of pg. 1 of tech spec i.e.DRV-11 -HPH-9B Alt. Drain to F,T , As per Sl. No. 12 of pg. 1 of tech spec i.e.DRV-14 -HPH-8A Normal Drain to HPH-7A , As per Sl. No. 13 of pg. 1 of tech spec i.e.DRV-20 - HPH-8B Normal Drain to HPH-7B , As per Sl. No. 14 of pg. 1 of tech spec i.e.DRV-17 -HPH-8A Alt. Drain to F,T , As per Sl. No. 15 of pg. 1 of tech spec i.e.DRV-23 -HPH-8B Alt. Drain to F,T , As per Sl. No. 16 of pg. 1 of tech spec i.e.DRV-27 -HPH7A Normal Drain to Deaerator , As per Sl. No. 17 of pg. 1 of tech spec i.e.DRV-34 -HPH-7B Normal Drain to Deaerator , As per Sl. No. 18 of pg. 1 of tech spec i.e.DRV-30 -HPH-7A Alt. Drain to F,T , As per Sl. No. 19 of pg. 1 of tech spec i.e.DRV-37 -HPH-7B Alt. Drain to F,T , As per Sl. No. 20 of pg. 1 of tech spec i.e.DRV-87 -LPH-5 Normal Drain to LPH-4 , As per Sl. No. 21 of pg. 1 of tech spec i.e.DRV-84 -LPH-5 Alt. Drain to F,T , As per Sl. No. 22 of pg. 1 of tech spec i.e.DRV40 -LPH-4 Normal Drain to LPH-3 , As per Sl. No. 23 of pg. 1 of tech spec i.e.DRV-43 -LPH-4 Alt. Drain to F,T , As per Sl. No. 24 of pg. 1 of tech spec i.e.DRV-77 -LPH-3 Drain D,S of Drip Pump , As per Sl. No. 25 of pg. 1 of tech spec i.e.DRV58 -LPH-3 Alt. Drain to F,T , As per Sl. No. 26 of pg. 1 of tech spec i.e.DRV-73 -Deaerator Overflow to F,T , As per Sl. No. 27 of pg. 1 of tech spec i.e.DMV-26 -Normal Make-up to Hotwell , As per Sl. No. 28 of pg. 1 of tech spec i.e.DMV-23 - Emergency Make-up to Hotwell , As per Sl. No. 29 of pg. 1 of tech spec i.e.ASV-2 -Aux. Steam to BFPTs , As per Sl. No. 30 of pg. 1 of tech spec i.e.CRHV-2 -CRH Steam to BFPTs , As per Sl. No. 31 Of Pg. 1 Of Tech Spec I.E.Dmcw-18 -Tg Dmcw Auxiliaries, As Per Sl. No. 32 Of Pg. 1 Of Tech Spec I.E.Dmcw Sg-8 -Sg Dmcw Auxiliaries, As Per Sl. No. B, Pg. 1 Of Tech Spec - 1, 4 Inch Ss Tubing 25 Meter For Each Tag, As Per Sl. No. C 1, Pg. 1 Of Tech Spec - Ss Fittings For Each Tag - Ss Fittings For Connection To Air Filter Regulator- For Each Tag, As Per Sl. No. C 2, Pg. 1 Of Tech Spec - Ss Fittings For Each Tag - Ss Fittings For Connection To Air Lock Relay- For Each Tag, As Per Sl. No. C 3, Pg. 1 Of Tech Spec - Ss Fittings For Each Tag - Ss Fittings For Connection To Ia Header Isolation Valve - For Each Tag, As Per Sl. No. C 4, Pg. 1 Of Tech Spec- Ss Fittings For Each Tag - Ss Equal Tee - For Each Tag, As Per Sl. No. C 5, Pg. 1 Of Tech Spec- Ss Fittings For Each Tag - Ss 1, 2 Inch Npt M X 1, 4 Inch Od Tube Connector- For Each Tag, As Per Sl. No. D, Pg. 1 Of Tech Spec - Commissioning Spares, As Per Sl. No. E, Pg. 1 Of Tech Spec - Valve Diagnostic And Configuration Software For All Tags, Mandatory Spares - As Per Sl. No. 1 Of Pg. 2 Of Tech Spec I.E.Pneumatic Diaphragm For Diaphragm Actuated Valve, Mandatory Spares - As Per Sl. No. 2 Of Pg. 2 Of Tech Spec I.E. Actuator Seal Kit For Pneumatic Cylinder Actuated Valve, Mandatory Spares - As Per Sl. No. 3 Of Pg. 2 Of Tech Spec I.E. Gland Packing, Mandatory Spares - As Per Sl. No. 4 Of Pg. 2 Of Tech Spec I.E. Stem, Mandatory Spares - As Per Sl. No. 5 Of Pg. 2 Of Tech Spec I.E. Plug, Mandatory Spares - As Per Sl. No. 6 Of Pg. 2 Of Tech Spec I.E. Seat, Mandatory Spares - As Per Sl. No. 7 Of Pg. 2 Of Tech Spec I.E. Cage, Mandatory Spares - As Per Sl. No. 8 Of Pg. 2 Of Tech Spec I.E. Retainer Ring, Mandatory Spares - As Per Sl. No. 9 Of Pg. 2 Of Tech Spec I.E. Seal Ring, Mandatory Spares - As Per Sl. No. 10 Of Pg. 2 Of Tech Spec I.E. Gasket, Mandatory Spares - As Per Sl. No. 11 Of Pg. 2 Of Tech Spec I.E. Smart Positioner Of The Valve, Mandatory Spares - As Per Sl. No. 12 Of Pg. 2 Of Tech Spec I.E. Seal Kit For The Positioner, Mandatory Spares - As Per Sl. No. 13 Of Pg. 2 Of Tech Spec I.E. Position Feedback Transmitter - Applicable If It Is Not Integral With The Smart Positioner, Mandatory Spares - As Per Sl. No. 14 Of Pg. 2 Of Tech Spec I.E. Complete Set Of Solenoid Valve For Pneumatic Type On, Off Valve, Mandatory Spares - As Per Sl. No. 15 Of Pg. 2 Of Tech Spec I.E. Solenoid Coil For Pneumatic Type On, Off Valve, Mandatory Spares - As Per Sl. No. 16 -I- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Actuator Seal Kit, Mandatory Spares - As Per Sl. No. 16 - Ii- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Gasket, Mandatory Spares - As Per Sl. No. 16 -Iii- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Complete Set Of Power Cylinder, Mandatory Spares - As Per Sl. No. 16 -Iv- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Smart Positioner Of The Valve, Mandatory Spares - As Per Sl. No. 16 -V- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Seal Kit For The Positioner, Mandatory Spares - As Per Sl. No. 16 -Vi- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Position Feedback Transmitter - Applicable If It Is Not Integral With The Smart Positioner-, Mandatory Spares - As Per Sl. No. 16 -Vii- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Complete Set Of Solenoid Valve For Pneumatic Type On, Off Power Cylinder, Mandatory Spares - As Per Sl. No. 16 -Viii- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Solenoid Coil For Pneumatic Type On, Off Power Cylinder, Mandatory Spares - As Per Sl. No. 16 -Ix- Of Pg. 2 Of Tech Spec I.E. Power Cylinder -As Applicable- I.E.Position Limit Switch For Pneumatic Type On, Off Power Cylinder, Mandatory Spares - As Per Sl. No. 17 Of Pg. 2 Of Tech Spec I.E. I, P Converter For Control

TRN :24741955
Central Government And Public Sector / Electrical Products
Murshidabad - West Bengal

INDIAN Hire Our Expertise :

  • Tender Bidding
  • Tender Consultancy
  • Tender Advisory
  • Identify Eligibility Criteria
  • Identify Penelty Clauses
  • Highlight Important Dates
  • Technical Bid Preparation
  • Offline Bid Preparation
  • Online Bid Preparation
  • Offline Bid Submission
  • Online Bid Submission
  • Track Corrigendum / Addendums
  • Attend Pre Bid Meetings
  • Consistent Liaison & Coordination
  • EMD Follow Ups

INDIAN - bidding
image

We heartily welcome your move to excel your business to new heights.

Set Tender Alert

Activate daily alerts to know the tenders available of your work.

Get alerts

Bidding Support

Ask experts, how to fill bid forms, submit bids, participate in bids.

Get in touch

GeM Registration

Looking for GeM Registration? Get in touch with us and we will do the needful.

Registration

Digital Certificate

Get DSC for e-Tendering, e-Auction, e-bidding, Corporations / Associations / Others Tenders

Purchase now

Tender Awards

Want to know who's got the tender and are looking for subcontracting?

Connect now

Projects

Government and other private players, Real-time Updates of Project Information

Get info

International Tenders

We almost cover all the regions and countries across the world. Click to take your business to new heights.

Start now

Web Design

Get the Best Offers & Deals, expertise in developing static websites, dynamic websites and e-commerce.

Design now