Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Air Conditioning Compressor
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of air-conditioning-compressor Tenders

List of latest air-conditioning-compressor Tenders in Indian Tenders. Click on any air-conditioning-compressor Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for air-conditioning-compressor Tenders.

Advance Search
  • All-Tenders (8)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
2 Construction
image image
State Government
TRN :49069125 |  21 May, 2025
Tender Value : 7.28 Lacs
 Kolkata - West Bengal
Tender for repairing of old ac machines at different places of state central library, kolkata- 1 dismantling,taken down of existing ac machines -( 4.5 tr tower ac machine & 1.8/2 tr split/cassette type ac) ( odus, idus and pipe lines)including all acceessories and handed over to the authority. 2 supplying, & fixing of m.s.angle structure for supporting the odus of the ac machines fabricated by fixing one no. additional angle iron of length approx 700 mm of ( 50 mm x 50mm x 5mm) with the existing 2 nos, ms angle whose one end will be duly grouted on wall incl. drilling 2 nos. holes in each channel cutting holes into the wall & gouting the same with cement concrete (1:1.5:3)etc.odus of the ac machine will be fixed on 2 nos. ms angle whereas rest 1 no. angle is to be used for making the platform for inspection purposewith the middle angle with 4 nos. ms flat of (25mm x6 mm) of length approx 460mm to be welded horizontally between those2 nos. grouted angle out of 3 nos. ms angle.whole structure to be painted properly by 2 coats of enamel paint.desing of the structure to be approved from e.i.c before execution of work.the entire structure must be safe to carry out maintenance of odus. 3 supplying,testing & commissioning of suction/ discharge copper pipe line in split air conditioning unit of 1.8 tr/2 tr & 4.5tr capacity tower ac machineincluding brazing, nitrile rubber insulation 6/9mm thick class o, etc complete as required. 4 supply and fixingcopper pipe line 3/8” 5 supply and fixing copper pipe line 1/2” 6 supply and fixing copper pipe line 5/8” 7 supply and fixing copper pipe line 1/4” 8 supply and fixing of 2.5 sq.mm 3 core cable wire for communication between indoor unit to outdoor unit.(brand approved by e.i.c) 9 supply and fixing of 2.5 sqmm 4 core frls copperflexible cable for communication between indoor unit to outdoor unit (brand approved by e.i.c) 10 supply & charging of r-32 gas with all arrangements as per direction of eic. 11 supply & charging of r-22 gas with all arrangements as per direction of eic. 12 system re -operation ,nitrogen gas flashing, after s/dressing, welding of copper pipe jointed line, gas pressure leakage testing with nitrogen gas,pressure holding upto 48 hrs. after leak testingmaking - negative 30psi vacuum for gas charge. 13 supply & fixing of outdoor unit fan blade of1.5 tr split ac machines. 14 checking,repairing of existing faulty pcb circuit with all required equipmentsof 1.5 tr. split ac machine as required as per dirction of eic. 15 checking,repairing of existing faulty pcb circuit with all required equipments of the circuit of 4.5 tr tower ac machine(both idu & odu) as per direction of eic. 16 supply & replacement of damaged fan motor forindoor unit of ( 1.8/2 tr) split type ac machines as per direction of e.i.c 17 s/f 3 phase electrical 3 pole contractor for 4.5 tr tower ac( make- chint ,cat-nc1-1810 or aprove make as per eic) 18 supply & replacement of outdoor unit fan motor of 1.8/2 tr splitac as per direction eic. 19 supply & replacement of outdoor unit fan motor for existing 4.5 tr tower ac(make: picl ac fan motor uh 1109, 250 w) or aprove make as per direction eic. 20 s/f ofrunning capacacitor 40+4 mfd (approved make) 21 supply & fixing of 1.5tr compressor(r-32/r-22) in the place of existing damaged one(aprove make as per direction of eic and suported for existing daikin/hitachi/blustar make ac machine). 22 supply & fixing compressor in the place of damaged one of existing 4.5 tr tower ac with all required arrangements (make: panasonic , model: c -sb373h8f) or aprove make as per direction of eic. 23 supply & laying pvc drain pipe 25mm dia with 6mm thick nitrile rubber insulation (make- supreme/oriplast) 24 hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, , per storey of building per vertical run
  • View Tender
  • Document
  • Bid Support
3 Health Services/Equipments
image image
Central Government/Public Sector
TRN :49019556 |  28 Jun, 2025
Tender Value : 0
 Pondicherry - Puducherry
Tender for supply of advanced high energy linear accelerator system 01 unit supply of advanced high energy linear accelerator system 01 unit for the department of radiation oncology , advanced high energy linear accelerator system – 01 unit , high energy linear accelerator system with srs-sbrt-gating systems with one year warranty. (for details please refer technical specifications document) , dosimetric qa systems including all hardware and software with licenses with one year warranty , hardware accessories and related turnkey works - chiller, printers, compressor, chiller piping, hvac, networking, ups & batteries, air conditioning with one year standard warranty. , four years extended warranty for the items 1.01, 1.02 & 1.03 , immobilization accessories required for patient treatment at the machine with one year standard warranty , other turnkey works including civil works, electrical works, firefighting, furniture & other accessory systems
  • View Tender
  • Document
  • Bid Support
4 Coal And Lignite
image image
Central Government/Public Sector
TRN :49020486 |  09 Jun, 2025
Tender Value : 7.96 Lacs
 Singrauli - Madhya Pradesh
Tender for procurement of compressor assembly of air conditioning system of pc 2000-8 (k-1, k-2, k-3) of amlohri project => limited
  • View Tender
  • Document
  • Bid Support
5 Construction
image image
State Government
TRN :49022392 |  13 May, 2025
Tender Value : 31.44 Lacs
 Gangapur - Maharashtra
Tender for providing electrical installation in, premises street light, water pump and fire extinguisher for the newly constructed zilla parishad primary health center (p .h .c)main building (g.f+f.f) [under scheme d.p.c. (general) year 2022-23, 34512595 construction expantion & m/ce & repairs of p.h.c/ phsc) at village,lasur stationtq. gangapurdist. chhatrapati sambhajinagar.= 1 supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit 2 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 3 supplying anderectingpvctrunking (pvc casing-n-capping)ofsize20 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 4 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 5 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize40 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 6 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 7 supplying and erecting green earth wire 1x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 8 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 9 supplying and erecting green earth wire 1x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 10 supplying and erecting mains with 4x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 11 supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 12 supplying and erecting mains with 4x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 13 supplying and erecting green earth wire 1x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 14 supplying and erecting mains with 4x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 15 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 16 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 17 supplying and erectingceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. 18 supplying and erectingmodular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 19 supplying and erectingmodular type switch 16aduly erected on provided plate and box with wiring connections complete. 20 supplying and erectingmodular type bell-push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. 21 supplying and erectingmodular type 3 pin 6amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. 22 supplying and erectingmodular type 3 pin 6 / 16amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 23 supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. 25 supplying and erecting pvc surface modular switch box with double mounting plate for 2module duly erected. 26 supplying and erecting pvc surface modular switch box with double mounting plate for 3module duly erected. 27 supplying and erecting pvc surface modular switch box with double mounting plate for 6module duly erected. 28 supplying and erecting pvc surface modular switch box with double mounting plate for 12module duly erected. 29 supplying and erecting 16 / 20 / 25 a starter (modular range) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 30 point wiring for light/bell/exhaust fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 31 point wiring for ceiling fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 32 wiring for plug on board withswitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no: wg-pw/cw 33 supplying and erectingled square / circular max. 11 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 34 supplying and erectingled square / circular max. 14 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 35 supplying and erectingled square / circular max. 18 w down lighter/ panel light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 36 supplying and erectingledpanel light(600mm x 600mm) max. 30 whaving crca powder coated housing,polystyrene diffuser havingsystem lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 37 supplying and erecting anodized aluminium corridor / passage / mirror light led fitting (2 feet) max. 12wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%,thd<10%,p.f. >0.95, operating range of200-270v, surge protection of 2 kv, life class of 50,000 hrs. at l70b50, including driver with end caps on provided pvc block / wooden board with 3 years warranty. 38 supplying & erecting inverter led batten 10w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 39 supplying & erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 40 supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. 41 supplying and erecting integrated led street light fitting26 to 30w ip65 & ik08 class having single piece pressure die-cast aluminium housing ,having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 42 supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg-odf/fls2. 43 supplying and erecting integratedled street light fitting 100-110w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 44 supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg-odf/ptl 45 supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg-bkt/wb 46 supplying & erecting 3w, 230v integral type led lamp suitable for b-22 / e-27 base.(night lamp) 47 supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg-fn/cf 48 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. 49 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. 50 supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg-fn/exf 51 supplying and erectingenergy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg-fn/cf 52 supplying and erecting fan hook of 10 mm. m.s. round bar grouted in rcc slab with making the site as original. 53 providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 54 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no fg-fas/msc 55 supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof abs plastic body, high grade ss inner tank & 3kw heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermalcut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250v, 50hz, a.c. supply with inlet and outlet, with 3 core pvc flexible copper wire leads duly tested and marking sr. no. and date of erection complete. 56 supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). 57 supplying & erecting 15mm brass non return valve for inlet pipe of storage water heater. 58 providing fiber reinforced pvc flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete. 59 supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 60 supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 61 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigerant having 22swg thickness and inner dia/size 12mm complete. 62 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigeranthaving 22swg thickness and inner dia/size 16mm complete. 63 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. ap-wcr/wc 64 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. ap-wcr/wc 65 supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) 66 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine waveinverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology completeas per specification no.ap-inv 67 supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 68 supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270v and output voltage 200-250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. 69 supplying and erecting switch disconnector fuse (sdf) switch 415v, 100a,open execution, four poleac23 a rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to is/iec 60947-3 part-1/3hrc - din type fuse, insulation voltage 1000 vfor enclosing in panel with rotary handle for on / off operation (without hrc fuse) 70 supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a,powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / cc foundation. 71 supplying, erecting & marking spmcb 0.5a to 5a, c-series with rated short - circuit breaking capacity (icn) 10kain provided distribution board as per specification no. sw-swr/mcb 72 supplying, erecting & marking spmcb 6a to 32a, c-serieswith rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 73 supplying, erecting & marking spmcb 6a to 32a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 74 supplying, erecting & marking dpmcb 6 a to 32 a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 75 supplying, erecting & marking tpmcb 6a to 32a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 76 supplying, erecting & marking tpmcb 40a to 63a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 77 supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40awith required wiring connections and lugs etc. in provided distribution board. 78 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board. 79 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63ain provided distribution board. 80 supplying&erectingtriplepole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flushmounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb 81 supplyingand erecting single pole and neutral distributionboard (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw-swr/mcbdb 82 supplying & erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb /tp mcb/fp mcb/rccb/rcbo complete erected on angle iron/gi frame. 83 supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb1 84 providing & erecting 4 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb (rate of 3 pole mccb +20% for 4 pole mccb= 5309x20%+5309=6370.80) 85 supplying and erecting cupboard for enclosing switchgears orforany other purposemadefromselected marine plywood planks 19 mm thick duly varnished/ painted from inside and from outside with brass hinges and locking arrangement with suitable lock with keys in duplicate. cupboard shall be duly grouted with suitable size of iron work in wall at the bottom. (size of cupboard 0.5x1x2+0.5x1x2+1x1x2= 4 sq.mtrs.) 86 supplyinganderectingiron, sheet metal work consisting of crcasheets, varioussectionsofiron,plates, chequeredplates,rods,bars,mspipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 50x50x4mm angle @ 3.4 kgs x 6 mtrs.= 20.40 kgs i,e 20 kgs. 87 supplying and erecting 525 v 3 phase, 50 hz., mpp type capacitor having minimum overcurrent capacity of 1.8 in,peak inrush current capacity 300 inand minimum life 150000 hourskvarbank of all polypropylenecondensers (app)withthestandard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kvarunitsofp.f. correctionforoperationon 3 phase 50 hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and providedwithterminalcoverbox completeerected onprovidediron bracketoronfloordulytestedby licensee.( original p.f=0.8 desired p.f = 0.95 for this multiplying factor is 0.421. so 0.421 x 46.440 = 19.55 i.e 10 kvar x 2= 20 kvar) 88 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 89 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al (double run) 90 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 91 supplying & erecting g.i. pipe‘a’ class 50 mmdia.erectedfor enclosingxlpearmouredcable on wall/poleas per specification no. cb-ce 92 supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 93 supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mmoutside dia. double wall corrugatedpipes (dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 94 supplying & erectingcast iron cable indicatorplate buried along with route of cable for pvc / xlpe armoured cableas per specification no. cb-cip 95 supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thickcomplete on pole/wallas per specification no. cb-sb 96 providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh-pl/opl 97 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 98 providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 99 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. ea-ep 100 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. ea-ep 101 providingpipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea-ep 102 supplying and erecting gi strip of required size used for earthing on wall and/or any other purpose with necessary gi clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsas per specification no. ea-ep.(25x3mm strip. perpole 1.5 mtrs. so for 13 poles 13nos.x1.5mtrs.= 19.5 mtrs. weight of strip @0.590kgs/mtr. so 19.50mtrs.x0.590kgs.=11.51 kgs.) 103 supplying and erecting minimum three & above star rated 1 phase, 230 v, 50 hz, submersible pump set of 1.5 kw/2hp suitable for erection on open well, pump having delivery head from 29to 7 m and discharge from 30 to 600 litres. . per minute& pipe of suction 50 mm/delivery 50 mm diameter erected with necessary h type clamps as per specification no. wp-osp 104 supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. 105 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c. submersible/centrifugal pump set up to 3 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 106 supplying & erecting carbon dioxide (co2) fire extinguisher of 4.5 kg. capacity cartridge type conform to is 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. m. s. flat with nut & bolts routed in wall complete. 107 making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (02x02x02 foundation for main control panel stand and for street light control panel 0.2x0.2x0.2mtr.=0.16 cu.mtrs.) 108 makingm- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). 109 supplying and erecting isi mark gi pipe 50 mm dia.‘b’ class at position with accessories complete as per specification no. cw-plb/gp. 110 supplying and erecting high density polythene pipe isi mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete. 111 supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. 112 supplying and erecting non return valve 50 mm dia in position made of gun metal complete. 113 lum sump provision towards service connection charges1 no.3 phase @ rs. 55000/-/per total rs.55,000/-
  • View Tender
  • Document
  • Bid Support
6 Agricultural And Floriculture And Silviculture Products
image image
State Government
TRN :48937513 |  10 May, 2025
Tender Value : 26.17 Lacs
 Nagpur - Maharashtra
Tender for supply and installation of furniture and allied electrical work at msambs division office, nagpur.2 providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm, 1.5 mm thick with 12 mm thick three layered flat pressed teak wood particle board bonded with bwp type exterior grade phenol formaldehyde synthetic resin conforming to is 128231990, laminated on both sides,novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubber cushioning beading to glass partitions, with wood boxing to all aluminium tubuler section as per approved drawing etc. compete(as directed by engineer-in-charge) 3 providing and fixing in position, single shuttered aluminium extruded powder coatedopenabledoorofoverallsize0.90mx2.40mwithaluminiumdoorframeof powdercoatedsection101.60x44.75mm,3.18mmthickandshuttercomprisingof powder coated section having bottom andlock rail of size 150 mm x 44.5mm x 3.00 mm thick top rails 47.62x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, with wood boxing to all aluminium tubuler section 3.00mmthickandforshutterplain glass panes 5 mm thick for top panels and 12mmthickbothsidelaminatedphenol bonded particle board panels for bottom panels etc. , i.s.i. mark , heavy duty, hydraulic floor springof150kilogramcapacity,having heavy duty concealed lock, necessary beading,glazingclips,pvcgaskets,250mm length tower bolts, 150mm diam. pad handle, etc. as per detaileddesignanddrawingor as directed byengineer in charge including all materials,labours, andequipment etc.complete(as directed by engineer-in-charge) 4 providing and fixing in position gypsum board false ceiling with 12.5 mm thick gypsum boards, screwed/fixed to the under structure of suspended g.i. grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. the gypsum board should be fixed to galvanized iron grid with necessary screws. the boards should be taped and filled from underside to give smooth, seamless ceiling. the rate should include necessary additional ceiling sections and intermediate channels. additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete(as directed by engineer-in-charge) 5 providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth of approved make, etc complete. 6 providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. 7 providing and fixing rollar blinds ami make or approved make & shade of 38mm round aluminiumchannelwithblackoutfabric&teltingwithchain(ball)systemwithall necessaryfixturesandfittingetc.complete.(sampletobefinalby engineer-in-charge prior execution of work) 8 providingand fixing 1.5 mm thick polyvenyl venyl chlorideflooring includingleveling thebasewithwhitecementincludingpastingwithappropriatematerialcleaningthe surface etc. complete 9 executive table @ 2250lx2100dx750ht including low height credestal @ 1200lx450dx650htproviding&fixingoftable @2250lx2100dx750httop& gable end to be made ofmembrane finish with soft water fall edges & curved panel &decoratedanodizedsectionmodestypaneltobemadeof18mmthick prelaminated particle board with pvc edge band. including credestal @ 1200l x 450d x 650h:- to be made out of membrane finish ( 2 openable shutter & 3 drawerpedestal in between ) as per drawing. 10 free standing table @ 1500lx600dx750htprovidingandfixingtableofsize1500x600x750mm.top:madefrom25mm prelaminatedparticleboard. alledgesarecoveredby2mm.thk.pvcedgebands glued by hot melt glue applied by auto edge banding machine.legs : c shape made from crca sheet with powder coat finish. modesty panel : made from 18mm both side prelaminated particle boards.all edges are covered by 0.8mm pvc edge bands glued by hot melt glue applied by auto edge banding machine.keyboard tray(withoutmousetray):- metalpowdercoated-blackcolor,cpu trolley:- metalpowdercoated-blackcolor,3drawerpedestalunit having overall size 392l x 450d x 680ht. mm. with central lock and key. drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. 11 free standing table @ 1350lx600dx750htprovidingandfixingtableofsize1350x600x750mm.top:madefrom25mm prelaminatedparticleboard. alledgesarecoveredby2mm.thk.pvcedgebands glued by hot melt glue applied by auto edge banding machine.legs : c shape made from crca sheet with powder coat finish. modesty panel : made from 18mm both side prelaminated particle boards.all edges are covered by 0.8mm pvc edge bands glued by hot melt glue applied by auto edge banding machine.keyboard tray(withoutmousetray):- metalpowdercoated-blackcolor,cpu trolley:- metalpowdercoated-blackcolor,3drawerpedestalunit having overall size 392l x 450d x 680ht. mm. with central lock and key. drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, 12 free standing table @ 1200lx600dx750htprovidingandfixingtableofsize1200x600x750mm.top:madefrom25mm prelaminatedparticleboard. alledgesarecoveredby2mm.thk.pvcedgebands glued by hot melt glue applied by auto edge banding machine.legs : c shape made from crca sheet with powder coat finish. modesty panel : made from 18mm both side prelaminated particle boards.all edges are covered by 0.8mm pvc edge bands glued by hot melt glue applied by auto edge banding machine.keyboard tray(withoutmousetray):- metalpowdercoated-blackcolor,cpu trolley:- metalpowdercoated-blackcolor,3drawerpedestalunit having overall size 392l x 450d x 680ht. mm. with central lock and key. drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particleboard, 13 conference table @ 3600lx1400dx750htproviding&fixingofmaintable@3600lx1400dx750ht-madeupof18+18mm thickmdftopwithpvcmembranefinishandwaterfalledgeprofile.aluminium anodizied finish beeding of 4mm thich is running all over the table top edge. gable ends is aerofoiled shape with front edges in pvc membrane finish and rest in prelaminated mdf with batton structure. gable ends should be hollow from inside for the provision of passingelectrical and datawiring. ,modesty panel:- to bemade of18 mm thick prelaminated particle board with pvc edge band access flap:- for wire manager 2 nos. 14 providing & arrangemnt of high back, synchronized mechanism with multiple locking, adjustable armrest, gaslift for seat height adjustment, standard 5-prong p/nylon basewith leatherite upholstery 15 providing & arrangemnt of high back, synchronized mechanism with multiple locking, adjustable armrest, gaslift for seat height adjustment, standard 5-prong p/nylon base with leatherite upholstery 16 providing&arrangemntofmidback,normalsyncro mechanism,fixedarmrest, gaslift for seat height adjustment, standard 5-prong/nylon base with leather upholstery 17 public seating chair. - 3 seaterproviding and fixing 3 seater public seating chair made of complete metal with legs in crome finish and seates in silver powder coating finish. 18 tea table 900mm x 750mm x 450mm for m.s. ante chamberprovidingandfixingofteatable900mmx750mmx450mmwith12mmthick coloureitchedtemperedglasswithbevelleddrawingmadeout of18mmthick waterproofingply.theouterlacestobefinishedwithhighquality4mmthik veneer or 1 mm thik mica etc. 19 kitchen trolleyprovidingandfixingstainlesssteelkitchentrolleyofoverall26heightand22 depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 x 20 x 22 on both sides of trolley of 12 or above size, panel having 40kilogramload bearing capacity of trolley made out of 20 mm puccoatedplywoodandcolourcombinationasdirectedbye-i-c.innersideofpanel covered by white mica ,100 mm s.s. decorative handle.(the width and height of individual compartments shall be kept as directed by engineer-in-charge) 20 providing andfixing 450mm x550mm size superiortype belgium mirrorwith16mm dia. nickel plated towel rod etc. complete. 21 providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm size as per detaileddrawing including vertical bothside polished kadappah stone 25 to 30 mm thick supports with kadappahtop 35 to 40 mm thick and polishedgranite16to20mm topwithsidestripsofgraniteatfrontandbothsidesof platform raised with two verticalgranitesupports15cmheightandtopgraniteof 75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (platform top size 5.00 m x 0.60 m and height is 0.75 m) 22 providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to605mm x590mm to605mm of8to10mm thicknessandconfirmingtois. 15622-2006(groupbla)ofapprovedmake,shadeandpatternforflooringinrequired positionlaidonabedof 1:4 cement mortar including neat cement float, filling joints,curingandclearing etc. complete. 23 providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming tocorrespondingi.s.fordadoandskirtinginrequiredpositionwith readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 24 providing projector - resolutation- xga, white brightness-3300ansi lumens,colour brightness-3300ansi lumens,contrast ratio- 15000:1,lamp life - 6000 hour,weight- aprox 2.5 kg, up to 3x briter colourincluding proector screen-6*4 with stand, with 15 m. hdmi cable and instalationcomplete 25 electrification work 26 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 27 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 28 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 29 supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 30 supplying and erecting mains with 1x1.5 sq.mm frlshcopperpvc insulated wire (earthing) laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 31 point wiring for light/bell/exhaust fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 32 point wiring for independent plug in pvc trunking (casing-capping) with 1.5 sq.mm(2+1e) frlsh grade copper wire, modular type switch,earthing and required accessories as per specification no: wg-pw/sw 33 wiring for plug on board withswitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no: wg-pw/cw 34 supplying and erectingmodular type switch 16 / 20 awith indicator,duly erected on provided plate and box with wiring connections complete. 35 supplying and erectingmodular type 3 pin 6 / 16amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 36 supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 37 supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, t8 led tube light (excluding tube light). 38 supplying and erectingled square / circular max. 14 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 39 supplying and erectingenergy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg-fn/cf 40 supplying and erecting fan hook of 10 mm. m.s. round bar grouted in rcc slab with making the site as original. 41 supplying, erecting & marking spmcb 6a to 32a, c-serieswith rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 42 supplying&erectingtriplepoleand neutral distribution board (tpndb), sp/tp mcbs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb 43 providing & erecting 3 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb 44 supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 20a, 2 pin plug & earth socket and 20a, 3 pin plugtop with 20a/30a single pole mcb having rated short - circuit breaking capacity (icn) 10ka complete erected on angle iron/ gi frame. 45 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 46 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. ea-ep 47 supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessarycopperclampsfixed on wall painted with bituminous paint with joints required. as per specification no. ea-ep. 48 supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 5.0 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap-ac/wac 49 supplying and erecting led panel light(600mm x 600mm) max. 30 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
  • View Tender
  • Document
  • Bid Support
7 Services
image image
Central Government/Public Sector
TRN :34438244 |  17 May, 2025
Tender Value : 0
 Neyveli - Tamil Nadu
Tender for gem bids for 50 air conditioning compressor of 1.5 tr capacity hermetically sealed rotary type refrigerant
  • View Tender
  • Document
  • Bid Support
8 Coal And Lignite
image image
Central Government/Public Sector
TRN :34432675 |  15 May, 2025
Tender Value : 0
 Nagpur - Maharashtra
Tender for gem bids for 1 compressor assy for air conditioning system for komatsu make hd465-7e0 dumper
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : air conditioning compressor
  • Nitrogen Compressor Tenders ,
  • Gas Compressor Plant Tenders ,
  • Centrifugal Compressor Tenders ,
  • Hydraulic Compressor Machine Tenders ,
  • Scroll Compressor Tenders ,
  • Compressors Tenders ,
  • Pressure Compressor Tenders ,
  • Ariel Compressor Tenders ,
  • Air Compressor Spares Tenders ,
  • Booster Compressor Tenders

Get air conditioning compressor Tender Alert...

033130

Related Searched Keywords : air conditioning compressor

  • Floor Tiling Tenders From Maharashtra
  • Tubewell Tenders From Delhi
  • Culvert Slab Tenders From West-Bengal
  • Civil Engineering Service Tenders From -Tamil-Nadu
  • Fencing Work Tenders From Andhra-Pradesh
  • Interlocking Tiles Work Tenders From Gujarat
  • Piling Work Tenders From Karnataka
  • Zone Work Tenders From Uttar-Pradesh
  • Flooring Tenders From Rajasthan
  • Road Under Bridge Tenders From Madhya-Pradesh

Read More


Tender Document

140731

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Disilting Work Tenders
  • Subways Tenders
  • Infrastructural Works Tenders
  • Flood Prevention Work Tenders
  • Civil Engineering Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App