Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Chemical Injection
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of chemical-injection Tenders

List of latest chemical-injection Tenders in Indian Tenders. Click on any chemical-injection Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for chemical-injection Tenders.

Advance Search
  • All-Tenders (4)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
2 Health Services And Equipments
image image
State Government
TRN :49020045 |  14 May, 2025
Tender Value : 0
 Belagavi - Karnataka
Tender for tender for rate contract supply of drugs items to bims belagavi - zince oxide 20gm cream,zinc syrup 60 ml,xylometazoline 0.1% nasal drops 10ml,white petrolium 100% pure jelly 500gm,white petrolium 100% pure jelly 30gm,wax solvent ear-drops 10ml benzocaine 2.7%w/v+chlorbutol5%w/v+paradichlorobenzene2%w/v+turpentine oil-15%w/v,vitamin-e drops 50mg/1ml-15 ml,vitamin-d3 60000 iusachet,vitamin d3 400-iu 15ml (drops),vitamin b complex 200ml (syrup),vitamin a syrup (60 ml),vitamin a solution (100ml),ultra sound gel (5kg),turpentine oil (100ml),tropicamide- 5ml eye drops,triple combination cream (momethasone 0.25% with tretin 0.1% with hydroquinone 2.0%) 15 gm,triamcinolone 0.1% w/v 5gm oral ointment,tretinoin 0.025% cream,topical5% emla cream 15gm,topical lignocaine 25mg/g, prilocaine 25mg/g cream-5%- 5 gm (cream),tobramycine 0.3%10ml (eye drops),tincture benzoine (100ml),timolol maleate 10ml eye drops,thrombophobe ointment (20gm),theophylline with etophylline (200ml syrup),sucralphate (170ml syrup),soft roll (15cm x3mtr),soft roll (10cm x3mtr),sodium valproate 200mg/100ml (syrup),sodium phosphate enema (100 ml),sodium hypochloride 5-6% solution 5ltr,sodium hypochloride 5-6% solution 20litr,sodium chloride (nasal drops),sodium by carbonet ip 600gms with sodium-chloride ip 230gms t packets 1x830,silymarin l-ornithine l-asparatate (200 ml syp),silver sulphadiazine -15gm cream,silver sulphadiazine -100gm cream,sildenafil oral suspension 10 mg/ml,salbutamol-nebulisation repsules 2.5mg 2.5ml (amp),salbutamol- nebuliser solution (salbutamol 100microgram/actuation pressurised inhalation 200 actuations(pi,cmi)-15ml.,salbutamol 2mg (100ml syrup),prednisolone acetate 1% + hpmc 0.25%-5 ml eye drop,povidone iodine solution in dark plastic bottle 500ml 5% w/v (500ml),povidone iodine ointment 5%w/v (15gm),povidone iodine ointment 5%w/v (125gm),povidone iodine cleansingsolution in dark plastic bottle 7.5 %w/v (500ml),potassium chloride (200ml syrup),pop roll 2.7 mtr x 15 cm (1roll),pop roll 2.7 mtr x 10 cm (1roll),phenytoin sodium 125mg (100ml syp),phenobarbiton 20 mg/5 ml-(100ml syp),permethrin 5% 30gm ointment,paracetamol 125mg/100ml (syrup),ors (who formula) 21gm,orodispersible probiotic sachets 2 gm-10 (sachets.),ondansetron 4mg/5ml 30ml (syrup),nuprep gel (114 gm),normal saline nasal 10ml drops,neomycin sulphate, polymyxin b sulfate and hydrocortisone 5 ml ear drop-,natamycin 5ml eye drops,mupirocin 2% 5gm ointment,multi vitamin with zinc 200ml (syrup),multi vitamin (zinc+b12+b-comp) drop-30ml,moxifloxacin 0.5%5ml eye drops,moxifloxacin 0.5% 5gm eye ointment,mometasone 1% 15gm (cream),micropore plaster size1.25cm x 9.1mtr 0.5 inch1roll (tissue plaster),micropore plaster size 7.5 cm x 9.1mtr 3inch 1roll(tissue plaster),micropore plaster size 2.5 cm x 9.1 mtr 1inch 1roll (tissue plaster),metronidazole 1.5% w/w -20gm gel,mefenamic acid with paracetamol 50+125mg/5ml 60ml (syp),mct oil 100ml (medium chain triglyceride (mct oil (100ml),luliconazole cream 1%w/v (10gm),liquid paraffin (60ml),lignocaine gel 2% (30gm),lignocaine 10% 50ml (spray),levetiracetam 100mg/ml (syrup),lactulose (200ml syrup),ketokonozol 2%with zinc payrithione 1% (100ml),ketoconazole 2% 20gm (cream),iron and folic acid-30 ml (drops),iron and folic acid (200ml syrup),ipratropium(500.0 mcg) + levosalbutamol / levalbuterol(1.25 mg) 3 ml (respules),hydrogen peroxide solution (100ml) amber bottle wrapped with black thick polybag with printed label 6% w/v,hmf sachet 2gm ( (lactodex hmf nutritional supplement sachet, 2 gm/sachet) sachet,haemocoagulase drops (10ml),glycin irrigation- (3ltr),glycerin-(100ml),glycerin & sodium chloride enema (20ml),glucose-sachets 75gm (dipsi-test),frusemide 10mg (30ml syp),framycetin sulphate 1% 10gm (skin cream),formoterol 6mcg with tiotropium 9mcg mdi 200 metered dose (inhalar),formaldehyde (5ltr),fluticasone propionate 50mcg (nasal spary) 120 meter doses,fluticasone propionate 250mcg with salmetero-25mcg mdi (120-metered dose inhalar),fluconazole cream 0.5%w/v-15gm,ferrous sulphate 20 mg/5ml (200ml syp),faropenem 50mg/5 ml (30ml syp),elemental calcium-300mg + elemental magnesium-75mg + elemental phosphorus-150mg + elemental zinc-4mg + vitamin d3-200iu3 (syp),eeg gel (250gm),ecg gel (250gm),dysodium hydrogen 100 ml(syp),dinoprostone gel for endocervical application( 3gm),dihydroxy1.6 dioxyhexane2.5(chemically bound formaldehyde11.2g glutaraldehyde 5gm benzalkonium chloride 5g alkyiureaderivative 3g aqueous base qs solution) (5ltr),digoxin 50mcg/1ml (30ml syp),diclofenac transdermal patch (100mg),diclofenac gel (diclofenac 1%+methyl salicylate 10%+menthol 5.0%) 1.00w/w (30gm),dichlorometaxylenol lotion (1 ltr),dextrose monohydrate s75 powder sachet (75gm),dextrometharphan hbr-10mg + chlorphenarmine maleate-2mg / 5ml100ml (cough syrup),dental oral-gel with lignocaine 2% 15gm,cotrimaxole 60ml (syp),clotrimazole 1%w/w 15gm (cream),clortimazole10ml (ear drops),clobetasol propionate 0.05%w/v salicylic acid3 %w/w 20gm cream,clindamycin hcl 60ml(syp),clasic paraffin gauge dressing 10cmx 10cm (pack of 100 dressings) (cuticell/equivalent),clarithromycine-250mg/5ml (syp),citro-sterile (5ltr),ciprofloxacin0.3%w/v eye/ear 10ml (drops),ciprofloxacin eye 10gm (ointment),ciprofloxacin 0.3%with 0.1%dexamathasone w/v 10ml (eye/ear drops),chlorhexidine mouth wash (100ml),chlorhexidine gluconate+cetrimide lotion+iso propyle alcohol (1ltr bottle),cetirizine hcl 5mg 60ml (syrup),calcium + vitamin d3 200ml (syrup),calamine lotion (60ml),budesonide-nebulisation solutions 0.5mg/2ml,budesonide (400mcg) with formoterol 6mcg mdi (metered dose inhalar),budecort(0.5) nibulisation solution per 2ml,betamethsone valerate cream tube (15gm),betamethasone 0.1% (ointment),benzoyl peroxide-2.5% 20gm (cream),benzoic acid 6% w/w and salicylic acid 3% w/w 15gm (ointment),beclomethasone with fusidicacid (10gm),barium sulphate powder (5kg),barium sulphate (1ltr),bandage cloth individually packed in poly-pack-1mtr x 20mtr (schedule f-ii as per d&c act),amoxycillin 400mg+clavulanate acid 57 mg 30ml (dry syrup),amoxycillin 125mg/1ml (drops),alcoholic hand rub 500ml (hand rub),adhesive tape (10 cm x 10 mtr roll),acyclovir 400mg ( (syp)),acyclovir 1% eye ointment,activated glutaraldehyde (5 litre),acid concentrate low potassium (1x20ltrs),acid concentrate bp with dextrose awa packing (1x20ltr),acetic acid 2% w/v ear dops,absorbent cotton wool (net weight) 500gm,zinc sulphate 20 mg dispersable (tab),xanithol nicotinate 500mg (tab),warfarin sodium-5mg (tab),voglibose-0.2mg (tab),vitamin-b complex(therapeutic) nfi (tab),vitamin -d3 60000 iu (tab),vitamin c chewable-500mg (tab),verapamil hydrichloride (tab) (calaptin) sr-40mg (tab),ursodeoxycholic acid 300mg (tab),trihexy phenidyl hydrochloride 2mg (tab),tinidazole-500 mg (tab),theophylline. with etophylline-23mg /77mg (tab),theophylline with etophylline 35mg/115mg (150 retard) (tab),thalidomide 100mg (tab),terbinafine-250mg (tab),telmisartan-80mg (tab),telmisartan-40mg (tab),telmisartan 40 mg+hydro chloro thiazide 12.5mg (tab),tamsulocin (0.4mg) with tolterodine (4mg) (tab),tamsulocin (0.4mg) with tolterodine (2mg) (tab),tamoxifen (tab),tadalafil 10mg with dapoxetine 30mg (tab),sodium valproate-500mg (tab),sodium valproate-200mg (tab),sildenafil citrate-50mg,sildenafil citrate-25mg,sertraline-50mg (tab),serratiopeptidase-10mg (tab),risperidone-2mg (tab),racecodotril 100mg-cap.,pyridoxine hydrochloride 40mg (tab),propranolol hydrochloride long-acting tab 20mg (ciplar la- 20mg) -tab,prochlorperazine (maleate) 5mg (tab),prednisolone-10mg (tab),prednisolone 40mg (tab),posaconazole-100mg (tab),phenytoin sodium (film coated)- 100mg (tab),phenylepherine 10mg (solvin or equivalant) (tab),phenobarbitone-60mg (tab),phenazopyridine hydrochloride (tab) (pyridium (tab)),pentoxyphilline 400mg (tab),paracetamol ip 500mg (tab),pantoprazole 40mg-(tab),oxybutinin 5mg-(tab),oxybutinin 2.5mg (tab),omeprazole ip 20mg (tab),olanzapine-10mg (tab),olanzapine -5mg (tab),ofloxacin ip 200mg (tab),norfloxacin 400mg-(tab),nitazoxanide-500 mg (tab),nintedanib 150mg (tab),nifedipine-10mg (tab),nifedipine sustained release (tab) 10mg (nicardia retard 10mg (tab)),nicorandil 10mg (tab),nicardia rtd 20mg (tab),naproxane-200 mg (tab),multivitamin-a-800 iu b1-0.5mg b-20.5mg b6-0.5 mg d3-50 iu niacinamide 10mg (tab),moxonidine 0.3 mg (tab),montilukast+levocetirizine-10mg+5mg (tab),misoprostol-200mcg (tab),mifepristone 200mg (tab),metronidazole 400mg-(tab),metoprolol-50mg (tab),metformin-500mg (tab),losartan 50mg (tab),lorazepam-2mg (tab),loperamide-2mg (tab),lithium carbonate-300mg (tab),levofloxacin 500mg (tab),levocetirizine 5mg (tab),levocetirizine 10mg (tab),lactobacillus 120mg (tab),labetalol 100mg (tab),ivermactin 12mg (tab),isoxuprine hydrochloride 20mg (tab),isosorbide dinitrate-10mg (tab),iron-folic acid(adult)containing iron equivalent to 100mg elemental iron and folic acid 0.5mg-335mg and 0.5mg (tab),imipramine hcl-25mg (tab),ibuprofen(film coated)400 mg (tab),hydroxychloroquin hcq 200mg (tab),haloperidol-5mg (tab),griseofulvin 250mg-(tab),glimepiride 1mg (tab),glibenclamide-5mg (tab),ginkgo biloba (tab),gastro-resistant acamprosate calcium 333mg (tab),furosemide (20mg) with spironolactone (50mg) (tab) (lasilactone 50mg),frusemide 40mg-(tab),folic acid 5mg (tab),fluoxetine-20mg (tab),fluconazole-150mg (tab),ethambutol 275mg with isoniazid 75mg with rifampicin 150mg (eg-(tab) akurit 3, tab trac 3),ethambutol 275mg with isoniazid 75mg with pyrazinamide 400mg with rifampicin 150mg (eg-tab akurit 4,tab trac 4) (tab),enalapril maleate 5mg (tab),doxylamine 10mg (tab) (doxylamine succinate pyridoxine folic acid (tab)lets, 20 mg),doxycyclin ip 100mg (cap),domperidone ip 10mg (tab),digoxin-0.25mg (tab),dicyclomine 20mg (tab),diclofenac sodium ip 50mg (tab),diazepam 5mg-(tab),desmopressin (tab)let 0.1mg (tab),darifenacin 7.5mg (tab) (derifenacin hydrobromide extended-release (tab) ip 7.5mg),darifenacin 15mg (tab),cyclophosphamide 50mg (tab),cotrimoxazole ip ds (sulphamethoxazole 800mg+trimethoprim 160mg) (tab),clopidogrel 75mg (tab),clonazepam 0.5mg (tab),ciprofloxacin ip 500mg (tab),chlorpromazine-50mg (tab),chlorpromazine-100mg (tab),chloropheniramine maleate 4mg (tab),chlordiazepoxide-25mg (tab),cetrizine 10mg, phenylephrine 10mg (tab),cetirizine hydrochloride bp 10mg (tab),cefixime 200mg (tab),carveidalol 6.25mg (tab),carbamazepine-200mg (tab),calcium+vitamin d3 500mg (tab),calcium citrate with malate 1000mg (tab) (calcium citrate malate 1000mg, vitamin d3 200 iu, elemental magnesium 100mg and zinc 4mg. (tab),bisacodyl(enteric coated) 5mg (tab),bisacodyl suppositories ip 10mg tab,bethanechol 25mg (tab),betamethasone 0.5mg (tab),azithromycine 500mg (tab),atorvastatin 10mg (tab),atenolol 50mg (tab),aripiprazole 30 mg tab,amoxycillin with pot-clavulanate 625mg (tab),amoxycillin 500mg (cap),amlodipine 5mg(tab),amitriptyline 25mg (tab),amiodarone 200mg (tab),alprazolam 0.25mg (tab),alfuzocin with dutasteride (tab) (alfuzosin hydrochloride 10mg + dutasteride 0.5mg generic drugs),albendazole ip 400mg (tab),acyclovir 400mg (tab),acitretin 25mg (cap),acetyl salicylic acid (enteric coated) 75mg (tab),vitamin k 1mg/1ml (injection),vitamin k 10mg/1ml (injection),vitamin b-complex 500mcg/ml 2ml (injection),vecuronium bromide 4mg 2ml (injection),vancomycin-500mgpantoprozloe 40mg/10ml with sterile water for injection (injection),tryphan blue 0.6% solution (injection),triamcinolone acetate (preservative free) 40mg (injection),triamcinolone 10mg (injection),triamcilone acetonide 80mg (injection),tranexamic acid 100mg/5ml (injection),tramadol 2ml (injection),total parenteral nutrition (tpn) 1500ml (injection iv),thiopental sodium 500mg (injection),thiamine 100mg/ml (injection),theophylline+etophylline 23mg+77mg/1ml (injection),tetanus toxoid 0.5ml amps (injection),tetanus immunoglobulin 500iu (injection),surfactant (each ml contains 25mg of phospholipids) intratracheal suspension sterile-4ml vial (injection),streptokinase 15lakh iu (injection),sterile succinylcholine chloride 20mg/ml (injection),sodium valproate 100mg/ml (injection),sodium tetradecyl sulphate (injection),sodium flourescien 20% 3ml (injection),sodium chondroitin sulfate 40mg with sodium hyaluronate 30mg with monobasic sodium phospate dihydrate (injection),sodium chloride iv 0.9% 3ltrs (injection iv),sodium chloride 3% 100 ml (injection iv),sodium chloride 0.9% w/v 100ml iv (injection iv),sodium chloride 0.9% w/v iv fluid 5ltr (injection iv),sodium chloride 0.9 %w/v 1000ml iv ffs (injection iv),sodium chloride 0.9 % w/v 500ml iv ffs (injection iv),sodium bicarbonate 7.5% w/v amp 10ml (injection),snake venom antiserum ip lyophilized polivalent powder form with sterile water for (injection),sevoflurane 250ml (injection),ropivacain hydrochloride in dextrose injection (ropin 0.75% heavy) 4ml (injection),ringers lactate solution for 500ml iv ffs bottle (injection iv),retiplace 18mg (injection),ranitidine ip 25mg/ml (injection),rabies vaccine-purified tissue culture 2.5 iu im/id 0.5 ml wfi combi pack 1ml x 1ml water for injection (injection),rabies immunoglobulin 1500 iu/5ml (injection),rabies human monoclonal antibody(rdna) 40iu/2.5ml (injection),pure crystalline essential amino acide i.v. infusion 200ml (hermin infusion or equivalent) (injection),protamine sulphate 10mg (injection),propofol 10ml 10ml (injection),promethazine hcl 2ml (injection),pralidoxime chloride 1gm 1gm+1water for injection (injection),potassium chloride 10ml (injection),plasma expander (hydroxy ethyl starch 6%)-500 ml iv (injection iv),piperacillin 4gm+tazobactam 0.5 gm (injection),pilocarpine nitrate 0.5% w/v 1ml (injection),phenytoin sodium 2ml (injection),phenobarbitone sodium 2ml (injection),pheniramine maleate 2ml (injection),pge2 infusion (injection),pentazocine lactate-30 mg1 ml (injection),paracetamol 500mg/100ml (injection iv),pantoprozloe 40mg/10ml with sterile water for injection (injection),oxytocin 1ml 5iu/ml (injection),ondansetron 2mg (injection),ofloxacin 100ml iv ffs (injection iv),octreotide-100mcg-1ml (injection),nor adrenaline-2ml (injection),nitro glycerin 25 mg-5ml (injection),neostigmine methyl sulphate-1ml (injection),multiple electrolytes and dextrose (paediateric)-iv ffs- 5% (injection iv),multi vitamin 10ml (injection),morphine 10mg/2ml (injection),midazolam 5ml vial (injection),metronidazole iv 100ml ffs (injection iv),metoclopramide 2ml (injection),methylprednisolone 1gm with sterile water for injection (injection),methylene blue vial 10ml/10mg (injection),methyl prednisolone 40mg vial with sterile water for injection (injection),meropenam 1gm with sterile water for injection (injection),mephentermine-10ml (injection),mannitol-(positive oral)100ml (injection),mannitol-(nagative oral)100ml (injection),mannitol 20% 100ml iv ffs (injection iv),magnesium sulphate 500mg 2ml (injection),l-ornithine l-aspartate 500mg (injection),lorazepam 2ml (injection),linezolid 300 ml (injection iv),lignocaine 4% 30ml(topical) (injection),lignocaine 20mg with adrenaline 0.01mg 30 ml amber colour vial (injection),lignocaine 2% w/v-30ml vial (injection),lignocaine 2% 50ml vial (equivalent to xylocard) (injection),levofloxacin 500 mg/100ml (injection iv),leveteracetam-5ml (injection),labetalol inj 5mg/20ml vial (injection),ketamine 10ml vial (injection),isoflurane-250ml (injection),iron sucrose-5ml (injection),iohexal 350mg/100ml (omnipaque) (injection),iohexal 300mg/100ml (injection),iodixanol 320 mg/100ml (injection),insulin human (rapid acting) 10ml-40 iu/ml (injection),hyoscine butyl bromide amp-1ml (injection),hydroxy propyl methyl cellulose prefilled syringe-3ml (injection),hydrocortisone sodium succinate 100mg/vial with sterile water for injection (injection),hyaluronidase 1ml amp 1500iu/ml (injection),human albumin 20% -100ml (injection),hepatitis-b vaccine vials (injection),hepatitis b immunoglubin 100 iu-1ml (injection),heparin 5000 iu-5ml (injection),haloperidol-5mg/1ml (injection),haemocoagulase aqueous 1n.i.h thrombin unit/ ml or equivallent unit-1ml (injection),glycopyrrolate 0.2mg/1ml (injection),gentamicin ip each 2ml contains gentamycin 80mg (injection),ganciclovir 250mg (injection),gadodiamide 0.5 mmol/ml 20ml (omniscan) (injection),frusemide inj 2ml (injection),fluphenazine 1ml (injection),fluconazole-100ml iv (injection iv),five-fluoroucracil 500mg/10ml (injection),ferric carboxy maltose- 500mg/10ml (injection),fentanyl citrate 50mcg/ml (injection),fentanyl 100 mcg/2ml (injection),erythropoietin 4000 iu pre filled syringe (pfs) (injection),enoxaparine (lmw prefilled syringe) 40mg (injection),drotaverine-2ml (injection),dopamine hydrochloride-5ml (injection),dobutamine-5ml (injection),diltiazam-5 mg/ml (injection),diclofenac sodium ip 25mg/ml (injection),diazepam-2 ml/5 mg ( (injection),dextrose 500 ml-iv ffs inj 10% w/v (injection iv),dextrose 500 ml-iv ffs 5% w/v (injection iv),dextrose 5% with sodium chloride 0.9%- 500 ml-iv ffs (injection iv),dextrose 25% 25ml (injection),dexamethasone sodium phosphate 2ml (injection),darbepoetin 40mcg/0.4ml (injection),cyno acrylate glue (injection),cyclophosphamide 500mg vials (injection),cyanocobalamin 500 mg+folic acid 15mg+niacinamide 200mg (injection),cloxacillin 500 mg (injection),cloxacillin 250 mg (injection),clindamycin phosphate-150mg/ml (injection),ciprofloxacin iv ffs-iv-100 ml (0.2% w/v) (injection iv),ceftriaxone 1000mg with sterile water for injection (injection),cefotaxime sodium 1000mg with sterile water for injection (injection),carboprost tromethamine 1ml 250mcg (injection),calcium gluconate 10ml (injection),bupivacaine hydrochloride 0.5% 20ml (injection),bupivacaine hcl in dextrose (heavy) 4ml (injection),bleomycin 1510 (injection),biphasic isophane insulin 30/70 (recombinant human monocomponent insulin)-10ml (injection),benzathene penicillin ip-12lakhs with sterile water for injection (injection),atropine sulphate100ml (injection iv),atropine sulphate 1ml amp (injection),atracurium besilate-2.5ml 10mg (injection),artesunate-60mg (injection),anti-d rh immunoglobin vial monoclonal-300mcg (injection),anti diphtheria 10000iu/ serum 10ml,ampicillin 500mg with sterile water for injection (injection),ampicillin 250 mg with sterile water for injection (injection),amphotercin b 50mg(liposomal) (injection),amoxycillin sodium+clavulanate potassium 1200mg with sterile water for injection (injection),amiodarone sterile concentrate-3ml 150mg (injection),aminophylline 10 ml amp (injection),amino acid infusion containing l-arginine histidine hcl isoleucine leucine arginine phenylalanine threonine tryptophan valine glycine sorbitol methionine lysine ffs 200ml (injection iv),amikacin sulphate ip 500mg/2ml (injection),amikacin sulphate ip 250 mg/2ml (injection),amidotrizoate meglumine(urograffin) sodium amidotrizoate 76% (injection),adrenaline 1ml (injection),adrenaline 11000/1ml(epitrate 1ml) (injection),adenosine 6mg (injection),acyclovir 500 mg/10ml (injection),acetylcysteine2ml (injection)
  • View Tender
  • Document
  • Bid Support
3 Construction
image image
State Government
TRN :49020462 |  15 May, 2025
Tender Value : 0
 Akola - Maharashtra
Tender for rate call for ( non dsr) items preparing estimate of under honble balasaheb thackeray haridra research and traning centre,vasmat,dist.hingoli =2 providing & fixing on site 75 mm thick reflexology ( pebbles ) stone flooring etc complete 3 providing & laying of hdpe pond liner of 750 micron thickness as per manufacturer’s specification & instructions from engineer in charge etc. complete. 4 orientation signage pole :- providing & fixing of orientation signage pole made up of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), with the size of 12x4inner frame and 60mm dia for support structure made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. the structure will be illuminated from within. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 5 identification signage pole :- providing & installation of identification signage pole made up of marine quality composite from 60mm dia for support structure {marine grade corrosion resistant & hydrocarbon solvent resistant) with all fittings fixture, hardwares , all as per design & drawings with all fittings, fixtures etc. complete , with the size of 6x1.5inner frame made of mild steel pipe od 60mm as the main support section is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 6 directional signage -5m single arm frp pole with haldi banner and leaf (signage): the single arm pole shall be made of 68 mm dia with metal hot dipped galvanized pipe support inside the frp cladded pole. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of is:3601 or equivalent, hotdip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted which usually require maintenance and care. pride suspended luminaire: 50 watt led suspended luminaire with height 450mm and width 500mm. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete 7 directional signage post :-providing & fixing of directional signage post (signage) with 5ft height and 700mm wide post and 48 mm dia support pipe with frame having and metal frame to show the directional or location of certain area. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer incharge etc. complete on site. structural stability certificate will be givenv 8 haldi information post :- providing & fixing of haldi information post- farming (signage) with 5ft height and 700mm wide and 48 mm dia support pipe with frame having a metal frame work to be used for provided information regarding the harida haldi project and which type of haldi crop grown on the particular field. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. these frp pole is individually crafted) which usually require maintenance and care. item is also including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structural stability certificate will be given etc complete. 9 pergolas type 1:- providing & fixing of type 1 pergolas with frp column 200mm x 200 mm in ms fabrication use in 88.2 od ms pipe 3 mm thickness. frp beam size 150 mm x 150 mm in ms fabrication 40 mm x 40 mm x 2 mm thickenss tube in framing. frp support for beam and column use in 75 mm x 75 mm x2 mm ms tube with frp cladding. frp thickness minimum 3 to 4 mm . column fittng in 12 mm x 150 mm anchor bolt in foundation. including installation machineries, scaffoldings, electricity, other site utilities in client scope. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structure stability certificate will be provided etc complete 10 pergolas type 2( for seating areas ):- providing & fixing of type 2 with frp column 200mm x 200 mm in ms fabrication use in 88.2 od ms pipe 3 mm thickness . frp beam size 150 mm x 150 mm in ms fabrication 40 mm x 40 mm x 2 mm thickness tube in framing. frp support for beam and column use in 75 mm x 75 mm x2 mm ms tube with frp cladding. frp thickness minimum 3 to 4 mm . column fitting in 12 mm x 150 mm anchor bolt in foundation. including installation machineries, scaffoldings, electricity, other site utilities in client scope. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. type 2 (for seating areas ). item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. structure stability certificate will be provided etc complete. 11 providing & fixing of type 01 module ( with back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made in combination of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 12 providing & fixing of type 02 module ( without back rest) frp seating with pvc wooden panel bench should be made in combination of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life . item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 13 providing & fixing of type 01 module ( with back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 14 providing & fixing of type 02 module ( without back rest) frp seating with pvc wooden panel (1.5m with wooden panel on top) bench should be made of 80 mm dia and 40mm dia pipe marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), 2.4m x 0.45m (module) the product should be an all weather proof & maintenance free with long design life. it should be self colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 15 dustbin frp dustbin should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant) all weather proof & maintenance free with long design life. the product should be 700 x 500 frp planter with basic design and 40 x 20mm sq. pipe to support the section of dustbin. it should be selfcolored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 to 4 mm average with sizes 2000x600 mm. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. 16 providing & placing at position type1 of 700mm x 305mm frp plantershould be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should be 700 x 305 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage shall be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 17 providing & placing at position type2 of 610 mm x 254 mm frp planterfrp planter should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should 610 x 254 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 18 providing & placing at position type3 of 510 x 200 frp planter frp planter should be made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant). the product should 510 x 200 frp planter with basic design and all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. the glass fiber reinforced polymer camouflage should be of thickness 3 mm average. product should come with a 12 month warranty against any manufacturing defect etc complete 19 tree grating:- providing & fixing of frp tree grating of size 1100 x 1100 x 25 mm frp material with various design options. made of marine quality composite (marine grade corrosion resistant & hydrocarbon solvent resistant), the product should be an all weather proof & maintenance free with long design life. it should be self-colored textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint, with long standing life. as per design & drawings with all fittings, fixtures etc. complete. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site.. 20 custom design, supply & installation /surfacing of epdm 6 mm & 19 mm rubber crumbs at site etc complete 21 providing & fixing of tumble twin with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 22 providing & fixing of animal mgr with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 23 providing & fixing of deluxe junior see saw with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 24 providing & fixing double post swing with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site etc complete 25 providing & fixing duck rider with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 26 providing & fixing fun walker single with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 27 providing & fixing step trainer with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 28 providing & fixing chest press double with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 29 providing & fixing shoulder press double with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 30 providing & fixing tai chi cum standing twister with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 31 providing & fixing leg press cum parallel bar with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 32 providing & fixing leg press cum seating twister with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site 33 providing & fixing of cobble stone of basalt 100 mm x 100 mm & 40 to 50mm thick etc complete 34 providing, fixing & installation of 18mm thick grc ( glass reinforcedconcrete ) of high quality iso grade upto 2.4 mtr height with 18mm grc chopped strands includingpure white cement , silica sand for finishingwith coating of sbr liquid or equivalent chemical for bonding work with all fittings, fixtures hardwares, wax polishing, caster, fitter, labour charges, scaffolding etc. complete as per design, drawings & manufacturer’s specification also as per instructions from engineer in charge etc. complete. sbr liquid will be used for bonding of various materials of the structure which also helps in waterproofing and adhesion giving it a long life durability specially multi dies will be made using cnc machine giving it a high precession for the design of the structure. material is made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant). its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life including structural stability certificationetc complete. 35 providing, fixing & installation of 4 mm thick frp ( fiber reinforced polymer) material high quality iso grade. frp material placed above grc of high quality iso grade material as per design, drawings & as per manufacturer’s specification & instructions from engineer in chargeincluding all hardener, fittings, fixtures, welder, patch work,labours charges, scaffolding etc. complete . the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life including structural stability certification etc complete. 36 providing & applying weather finish coating & lackering of 100microns to all surfaces of grc & frp with all rubbing, finishingwith all equipments, labours, scaffolding all as per design, specification & instructions from engineer in charge etc. complete 37 waterproofing cum insulation composite system:-cleaning the surface to make it dust free andsludge free, removing any extended portions by grinding and if required using suitable equipment’s and should be totally dry & have proper slope for free flow of water preparing the surface by spray applying a coat of bitumen primer @0.25-0.35kg/square metre over the entire dust free surface. providing and applying single layer of ultraplast b app- 4mm (atactic polypropylene polymer) modified water proofing membrane reinforced with non-woven polyester matt 160+20 g/m2 having polymer film as a top surface. minimum tensile strength in longitudinal and transverse direction as 750n +150 / 600n +120/5cm (astm d 5147). minimum nail shank tear resistance in longitudinal and transverse direction as 300/300n + 100 n (astm d 4073) elongation in longitudinal and transverse direction 40+8% / 45+9%. softening point of membrane not less than 150 + 5 degree celsius consisting of a coat of technonicol bitumen primer no 01 primer @ 0.25- 0.35 ltr./sq.mtr with a relative viscosity of 15-40 s,. over the primer coat, the layer of membrane shall be laid using butane / lpg torch and sealing all joints with minimum 75 mm side laps & 100 mm end laps to form a monolithic system. the laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane etc complete. 38 providing and laying leed certified carbon prof 300 extruded polystyrene 50mm thick having thermal conductivity of 0.028 w/mk (astm c 177) with compressive strength of > 300 kpa (astm d 1621 en 826) and density of 30-35 kg/m3. long term water immersion astm c 272 (en12087) < 0.7% over the waterproofing membrane having shiplap arrangement. work shall be done through the authorized applicator of the manufacturer of the insulation boardetc complete. 39 prviding & fixing glassreinforced concrete (grc)25mm jali as per deign & details etc completed. 40 providing and fixing heavy gauge galvinsed iron 50”fan with autoopening 10shutters, drop hamper exhaust fan systems with 6 no.ss blades with low noise , cfm:-25890, auto opening shutters damper type 415v,50hz, 1.5hp motor, 3hp with fitting etc complete.cellulose cooling pad 1200mmx600mmx100mmt one pad contain area of 1 0 sqft, leading kit with pipeline upto frame,- bypass, filter flush system etc.6”aluminum frame for the above coolingpads with top water distribution and bottom gutter, aluminum 41 providing & fixing air circulation fans 7 blades ss aluminum powder coated of model gtacf-40-70, size of d320mmxh400, 50hz , 1400 rpm, 220v, 120w, single phase, 70 ft airflow etccomplete. 42 automatictemp humidity controller- providing & fixing microprocessor based temp & humidity controller excluding moisture sensors, electrical control panel for fan,cooling pad, pump, mcb, contractor, olr, auto manual switching on/of fswitches ip55 cabinet, electrical cable 1 .5sqmm 4core for fans and pads,sensor cable 4core 0.5square mm etc complete. 43 providing & fixing controller - plc & hmi based control, drip valves control -2 nos,dosing valves control- 3nos ( a-b,c-acid), filling pump, system pump, air pump control, mixing valve control, phase missing prevention, over current prevention control, operation modes: auto -manual-bypass. 44 providing & fixing dosing unit includes dosing channels - 3nos @400lph with flow indicatiors & regulators, dosing valves - 3 nos (a-b,c-acid ), system pump - 30klph@35m head- ss 316 grade, dosing line filters-3nos 45 providing & fixing flow sensor of 3” as per design & drawing etc complete. 46 providing & fixing regenerative air blower-385cfm for 2 stocks mixing as per design & drawing etc complete. 47 providing & fixing solenoid valvesof 2” as per design & drawing etc complete. 48 providing & fixing exhaust fans -1.5hp 3phase- 16 nos4 controls ( each control 4 fans) pad pump - 3hp, 3phase- 1no fogging pump-5hp- 1no acf- 0.5hp- 1phase- 32nos - 1 control (3 phase load distribution) temperature sensor - 1no etc complete. 49 providing & fixing pressure release valves of 2” as per design & drawing etc complete. 50 providing & fixing total galvinsed iron structure of column pipes, profile, zig-zag spring, locking, perlins, tie bar, cross, gutter purlin, hockey , hockey memeber, hockey runner, nagarpatta, galvinsed gutter sheet, l, f brcackets, clamps, bolts , nuts, self drilling screw, spring, sliding pulley, netring, curtain clamps, door cup, handle, fiber door, hole pass. above all incudes, complete structure- erection, fixing etc complete. 51 poviding & fixingpoly film, 50% shade net, 30% side net with 6.5m center height,d rain out, israel make ginegar diffuse 200micron. above all incudes, making foundation, completestructure- erection, fixing etc complete. 52 providing & fixing high-tech irrigation system including inline drip lateral, inside main and sub main pvc pipes, fogger system, sand filter, disc-filter, ventury system with instillation & testing. 3024 sqm etc complete. 53 providing &fixingweed control mat 3000 sq mtr 120 gsm as per design & drawing etc completed. 54 providing &fixingplastic trough20:50:20500 micron 6000 running mtr etc complete. 55 providing & supplying low electrical conductivity coco-peat as instructed etc complete. 56 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 300mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 57 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 600mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 58 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 900mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frame etc complete 59 constructing stormwater channel with (random rubble masonary) rrm stone masonry in cement mortar 1:5foundation concrete 1:3:6 mix, raking rrm joints and cement grouting as perstandard design including excavation refilling anddisposalof surplus earth, providing and securely fixing ci frame in rrm and ci grating (heavy duty) etc. complete. (ci grating and frame make: neco or equivalent) 1200mm wide channel, 300mm deep at start with 1:200 slope, heavy duty ci grating and frameetc complete 60 supply, installation, testing, and commissioning of the electrical trench, with dimensions of 1300mm length, 1300mm width, and 1300mm depth, which includes a cover at every 15-meter interval, and also includes all necessary civil work to complete the electrical trenchetc complete 61 providing and fixing of ‘seamless gloss’ tiles of himalyan acoustics / baux / baswa or equivalent20mm thick with square edge made of gloss base panel (non-magnisite) with wood fibre 1mm width cement composites covered with acoustically transparent absorptive microfibers on the front side pasted on site with sprayable glue and colour as per the choice of the architect/ person in charge with seamless finish. has excellent noise absorption of 0.85 nrc as per iso: 354-1985 and astm 423-90 a, stc of 47 as per astm e90/413 for 25mm, density 400 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60o celcius(140o farenhite) for 15 days= no deterioration. conforms to en 131682001 and are rohs complaint and anti-bacterial test as per jis-z2801-2010.to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results( ceiling absorption nrc 0.85) etccomplete. 62 providing fibrette doodle 20 ceiling tiles of himalyan acoustics / baux / baswa or equivalent made of wood fibre cement composites with an option of colours as per the choice of the architect/ person in charge of size 1200 x 600 mm highly recommend for walls / ceilings. has excellent noise absorption of 1 nrc as per iso: 354-1985 and astm 423-90 a, density 400 kg/ m3, meets stringent fire ratings astmd-876 and fire class -1 and class p-not easily ignitable as per bs-476-part 5,6,7, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60° celsius (140° fahrenheit) for 15 days= no deterioration. tested as per en 131682001 and are rohs complaint. to be installed on g.i studs 600x600mm centre to centre2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life witha backing of himalyan acoustics 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results(ceiling absorption nrc 1 ) etc complete 63 providing and fixing of ‘seamless gloss’ tilesof himalyan acoustics / baux / baswa or equivalent wth 20 mm thick with square edge made of gloss base panel (non-magnisite) with wood fibre 1mm width cement composites covered with acoustically transparent absorptive microfibers on the front side pasted on site with sprayable glue and colour as per the choice of the architect/ person in charge with seamless finish. has excellent noise absorption of 0.85 nrc as per iso: 354-1985 and astm 423-90 a, stc of 47 as per astm e90/413 for 25mm, density 400 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60o celcius(140o farenhite) for 15 days= no deterioration. conforms to en 131682001 and are rohs complaint and anti-bacterial test as per jis-z2801-2010.to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results (ceiling absorption nrc 0.9 )etc complete. 64 providing wooden micro perforated fr grades 600x600 / 600x1200 16mm made of mdf backed with acouscal fleece providing sound absorpon of abs. coeff. 0.92 @125hz as per (equivalent to iso: 354-1985 & astm 423-90).to be installed with hidden aluminium profile conforms to aluminium alloy 6063-t6.temper as per bs:1474-1987. the density per panel is 750-800 kg/m3. these panel are made from acouscal fibreboard with linear perforaons for excellent uniformity. the perpendicular holes areavailable on the panel. wooden micro perforated can be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick,1000 gsm acousc wool tested as per fire retardant astmd 635- 1991/insulation and is 15061-2002 for excellent result wall treatment upto 8ft height etc completeof himalyan acoustics / baux / baswa or equivalent etc complete. 65 providing and fixing ‘aphony cortex’ splendortiles made of wood fibre 1mm widthcement composites 25 mm thick (non magnesite bonded) and covered with acoustically transparent woven fabric on the front side, with an option of colours as per the choice of the architect/ person in charge of size 1200x600/ 600x600 mm.providing sound absorption of 1 nrc as per iso:354-1985 and astm 423-90 a, stc of 49 as per astm e90/413 meets the stringent fire ratings astmd- 876 and bs:476, weather resistant as per is 3308 thermal conditivity result 45 w/m2/kas per is:3346-1980. conforms to en 131682001.to be installed with pvc h profile on g.i studs600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of himalyan acoustics. 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 thermal conductivity test , w/mk , as per astm c 518 test result ( sc-6490) -0.03312for excellent results.wall absorption nrc 1 etc complete. 66 providing fibrette doodle 25mm walls himalyan acoustics / baux / baswatiles made of wood fibre cement composites with an option of colours as per the choice of the architect/ person in charge of size 1200 x 600 mm highly recommend for walls / ceilings. has excellent noise absorption of 1 nrc as per iso: 354-1985 and astm 423-90 a, density 400 kg/ m3, meets stringent fire ratings astmd-876 and fire class -1 and class p-not easily ignitable as per bs-476-part 5,6,7, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% rh at 60° celsius (140° fahrenheit) for 15 days= no deterioration. tested as per en 131682001 and are rohs complaint. to be installed on g.i studs 600x600mm centre to centre2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life witha backing of himalyan acoustics 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002 for excellent results wall absorption nrc 1 etc complete. 67 providing and fixing ‘aphony fibril’ tiles20 mm with himalyan acoustics / baux / baswa or equivalenttaper edge made of compressed wood fibre made with (non-magnesite bonded) inorganic compound with mat blackcolour of size 600x1200/600x600mm. has excellent noise absorption of 0.70 nrc as per iso: 354-1985 and astm 423-90 a, stc of 48 as per astm 90/413 density 650-750 kg/ m3, meets stringent fire ratings astm d- 876 and bs:476 , tested as per astm c 367-99 to be installed on g.i studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of himalyan acoustics. 50mm thick,1000 gsm absorb wool tested as per fire retardant astmd 635-1991/insulation and is 15061-2002for excellent results.make etc complete. 68 providingfloor carpet ofhimalyan acoustics / baux / baswa or equivalent with specification : weight :875 dynamic loading ( bs 4052)nominal thickness ( mm): 4.00color fastness tested as per.is 5641wash ( is 11969)light ( is 0686)flammability test ( is 5641) etc complete. 69 providing and fixing of acoustic door ofhimalyan acoustics / topakustik / baswa or equivalent of 56 mm having an stc rating upto 59.6 @ 100 hz as per iso:140/astm90/413. the door will be filled with high acoustic materials of 2 layers of 8 mm water proof acoustic ply with dampner sheet, 2 layers of 10mm thick absorb wool 300 gsm, sound dampner 12mm 1218x1218 mm made of 10 mm compressed wood cement composites 1250kg/m3 and 2mm dampner sheet 37 stc as per iso 140 (part-iii) - 1995. final finish with teak ply 4mm thick interior and exterior side. door frame will be made of teak wood teak wood/ engineered wood. frame on all four sides or three sides frame and drop seal below will be provided along with the door. high load bearing hinges will be provided along. fr tested as per is:3614 (pt. ii) & bs: 476-(pt.20 & 22). 70 providing and fixing of teak wooden flooring of himalyan acoustics / baux / baswa or equivalent of20mm thickness with polish. teak wooden flooring with tongue and groove system with size 510x90x20mm. termite treated seasoned. to be installed on ply board 16mm.floor polish charges included etc complete. 71 supply & installation of auditorium tip-up chairs:seat to be mounted on center pedestal 75mm x 100mm mounted on ms plate 200mm x 200mm x 6mm thickness. seat & contoured back made in cold injection moulded pu foam of density of 60kg/m3 and 46kg/m3 respectively over metal structure.19 0colored cushion (fabric colour to clients choice) with removable seat cover.seat and backrest frames are made out of metal frame structure black powder coated.upholstered back to with multi angle adjustable mechanism upto 30 degrees inclination.counterweight silent/noiseless tip up seat mechanism, seat shall be able to be removed easily for cleaning and maintenance without the need of any tools. solid armrests laminate finished (wooden appearance) seat number in oval acrylic and row number in metal plate, with provision for wiring to put led illumination. strength & durability of seat to comply to en12727: 2016 for level 4 load test.fire resistance to meet bs5852 & bs 7176warranty 5 years. price inclusive of transportation with all leads and lifts etc, complete. 72 statue- balasaheb thakreproviding statue of 15 ft height in 1st quality fiber material with metal armature (jindal). with internal structure pipe 100mm dia pipe welded together with support pipe in between and arm also with the same pipe of size 1mtr-0.5 mtr the overall height would be 3.5mt from ground. item is including installation with all fittings fixture, hardwares , scaffolding, all as per design & drawings & as per instructions from engineer in charge etc. complete on site. material made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. structural stability certificate will be given. 73 sculpture-1 man sitting providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 74 sculpture 2 man with hammer sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 75 sculpture 3 women standing- sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care 76 sculpture 4 buffalo- sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 77 sculpture-5:- man with calf and calf sculpture -providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 78 sculpture-6:- man standing sculpture providing & fixing made of frp material as per 3 to 5 ft heights as per design & drawings with combination of 48 mm and 26mm dia pipe and cage work made up of metal path with 20-25 thickness width made of metal support inside and above marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. item is including installation with all fittings fixture, hardwares , all as per design & drawings & as per instructions from engineer in charge etc. complete on site. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5 viscosity aliphatic paint. with long standing life. require maintenance and care. 79 selfie point i love haldi providing & fixing of 2.8m x 2.8 m with height of 2.8m. frp kiosk. made of frp material with dark wood finish. frp dustbin included in the kiosk. made of marine quality composite {marine grade corrosion resistant & hydrocarbon solvent resistant), inner frame made of mild steel pipe is:3601 or equivalent, hot-dip galvanized 60 microns, post fabrication. its reinforced with glass fibre cs 1040 450gsm e glass matt with a density of 450g/m2 & 300gsm emulsion chopped strand matt with a density of 300g/m2. the product is an all weather proof & maintenance free with long design life. its self-coloured textured surface finish with scratch resistant, aliphatic grade u.v. stabilized pu paint with uv stable polyurethane 120 s+/-5viscosity aliphatic paint. with long standing life. item is including placing, installation with all fittings, fixture, hardwares , all as per design, drawings & as per instructions from engineer in charge etc. complete on site.
  • View Tender
  • Document
  • Bid Support
4 Construction
image image
State Government
TRN :49023607 |  16 May, 2025
Tender Value : 22.62 Lacs
 Lucknow - Uttar Pradesh
Tender for tender for construction and renovation work of community center located in sector-d of kanpur road scheme - rcc repairs 2 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge. 3 75mm average thickness 4 50mm average thickness 5 25 mm average thickness 6 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 7 bars upto 12 mm diameter 8 bars above 12 mm diameter 9 drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in rcc beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of engineer-in-charge.upto and including 12mm dia. 10 providing, mixing and applying bonding coat of approved adhesive on chipped portion of rcc as per specifications and direction of engineer-in-charge complete in all respect.epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make 11 providing, mixing and applying sbr polymer (of approved make) modified cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of engineer-in-charge.note: measurement and payment: the pre-measurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 n/sqmm2). 12 25 mm average thickness in 2 layers. 13 50 mm average thickness in 3 layers. 14 providing and laying sbr polymer modified (of approved make @ minimum 2% by wt. of cement used) plain/reinforced concrete jacket for the structuralmembers e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of rcc member.note: rates shall be for finished surface area of concrete and shall include the cost of making holes in existing rcc slab, if required, for pouring concrete in shuttering mould of jacket and appropriate approved super-plasticiser forrendering concrete as flowable self compacting and sbr polymer but shall exclude cost of reinforcement, bond coat, shear keys, centering and shuttering, strutting, propping etc (payment under this item shall be madeonly after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) 15 50mm thick in grade m 25 with cement content not less than 330 kg per cum 16 75mm thick in grade m 25 with cement content not less than 330 kg per cum 17 100mm thick in grade m 25 with cement content not less than 330 kg per cum 18 providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of engineer-in-charge.(the payment shall be made on the basis of actual weight of approved grout injected.) 19 epoxy injection grout in concrete/rcc work of approved make 20 providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the engineerin- charge.wooven pvc cloth 21 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stoneaggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineer- in-chargenote: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface hasbeen satisfactorily evaluated by sounding/tapping with a blunt metal instrument. 22 50mm thick in grade m 25 with cement content not less than 330 kg per cum 23 75mm thick in grade m 25 with cement content not less than 330 kg per cum 24 providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of engineer-in-charge. 25 providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of l shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge. 26 mild steel or iron work in plain work such as in r.c.c. or r.b. (when not included in an over all rates ) including bending for proper completion of the workand including supply of steel and its wastage , bends, hooks and authorised overlaps shall be measured up to floor two level. 27 centering and shuttering including strutting, propping etc. and removal of form for : lintels, beams, plinth beams, girders, bressumers and cantilevers 28 centering and shuttering including strutting, propping etc. and removal of form for : columns, pillars, piers, abutments, posts and struts 29 centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thic 30 waterproofing and terracing 31 providing and laying in situ five course water proofing treatment with app (atactic polypropylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd layer of roofing membrane app modified polymeric membrane 2.0 mm thick of 3.00 kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 5th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 32 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 33 miscellaneous works 34 providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, includingadditional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia m.s. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with m.s. tubes, m.s. tube challis, m.s. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. the scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of engineer-in-charge.note:- (1) the elevational area of the scaffolding shall be measured for payment purpose. (2) the payment will be made once only for execution of all items for such works. 35 disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of engineer-in-charge. 36 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : cement mortar 1:6 (1 cement : 6 coarse sand) 37 cleaning of under ground sump, over head r.c.c. tank ( independent staging) including disposal of slit and rubbish, all as per direction of engineer-in-charge.the cleaning shall consist following operations:-(i) tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.(ii) entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) chlorination of rcc internal surface by liquid chlorine.(iv) the treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) finally the surface shall be treated with ultraviolet radiation etc. as per direction of engineer-in-charge. 38 door-window repair 39 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) 40 renewal of old putty of glass panes (length) 41 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead asper direction of engineer - in- charge. 42 extra for cutting reinforcement bars manually/ by mechanical means in r.c.c. or r.b. work (payment shall be made on the cross sectional area of r.c.c. or r.b. work) as per direction of engineer-in-charge. 43 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. in cement mortar 44 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :of area beyond 3 sq. metres 45 casement door double panel with french (false) mullion with zinc alloy (zamak) 3d hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.using r4 series with frame (64 mm & above) x (55 mm & above) & sash (64 mm & above ) x (100 mm& above) & french (false ) mullion (64mm & above) x (60 mm & above). (height above 2.5 metre) 46 toughened glass 12 mm thickness 47 finishing work 48 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 49 20 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 50 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 51 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete. 52 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 53 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work (two or more coats) over and including water thinnable priming coat with cement primer 54 applying priming coat:with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 55 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :one or more coats on old work 56 washrooms 57 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.for thickness of tiles 10 mm to 25 mm 58 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 59 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including isi marked stainless steel butt hinges with necessary screws 60 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm 61 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm 62 providing and fixing aluminium sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : chemical injection
  • Erythromycin Lactobionate Injection Tenders ,
  • Ondasteron Inj Tenders ,
  • Arte Ether Inj Tenders ,
  • Hydroxypropyl Methylcellulose Inj Tenders ,
  • Sodium Salicylate And Phenyl Butazone Inj Tenders ,
  • Acetylcysteine Inj Tenders ,
  • Methylcobalamin Inj Tenders ,
  • Normal Saline Inj Tenders ,
  • Amoxicillin Clavulanate Injection Tenders ,
  • Butalex Injection Tenders

Get chemical injection Tender Alert...

950166

Related Searched Keywords : chemical injection

  • Water Proof Treatment Tenders From Maharashtra
  • Earth Filing Tenders From Delhi
  • Wall Work Tenders From West-Bengal
  • Earth Works Tenders From -Tamil-Nadu
  • Drainage System Tenders From Andhra-Pradesh
  • Brickwork Tenders From Gujarat
  • Piling Tenders From Karnataka
  • Canal Works Tenders From Uttar-Pradesh
  • Flood Gate Tenders From Rajasthan
  • Flooring Item Tenders From Madhya-Pradesh

Read More


Tender Document

156666

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Water Proofing Treatment Tenders
  • Borewell Tenders
  • Canal Work Tenders
  • Earth Dam Tenders
  • End Wall Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App