Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Metal Lamp
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of metal-lamp Tenders

List of latest metal-lamp Tenders in Indian Tenders. Click on any metal-lamp Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for metal-lamp Tenders.

Advance Search
  • All-Tenders (26)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
11 Construction
image image
State Government
TRN :49056754 |  30 May, 2025
Tender Value : 0
 Kolkata - West Bengal
Tender for supply of spare parts as replacement of defective ones for flood light fittings at kishore bharati krirangan, survey park, santoshpur, kolkata.-1 supply& delivery 415v 2 kw compact quartz metal halide lamp having luminoius efficacy of not less than 105lm/w, cct-5600k, cap-base:- cable etc.(make-philips model no.-mastermhn-sb 2000w/956 400v k12s-7 wh ho). 2 supply& delivery of ignitor for2 kw mh lamps (make-philips/ledvance ) 3 supply and delivery of 415v, 2kw copper ballast (make-philips/lt/bajaj)
  • View Tender
  • Document
  • Bid Support
12 Housing Urban And Rular Development
image image
Government Departments
TRN :49056962 |  29 May, 2025
Tender Value : 5.80 Crore
 Gaya - Bihar
Tender for tender for special repair work at jnv gaya-i (bihar) - school building 2 structural repair & retrofitting 3 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 4 50mm average thickness 5 25 mm average thickness 6 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 7 bars upto 12 mm diameter 8 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 9 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 10 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in grade m 25 with cement content not less than 330 kg per cum 12 50mm thick in grade m 25 with cement content not less than 330 kg per cum 13 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 14 expansion joint treatment 15 providing and fixing of expansion joint system related with floor location as per drawings and direction of engineer-in-charge. the joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per astm b221-02. the system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. system shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. the cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. the self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. provision of moisture barrier membrane in the joint system to have watertight joint is mandatory requirement all as per the manufactures design and as approved by engineer -in- charge. (material shall confirm to astm 6063). 16 floor joint of 100 mm gap 17 providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of engineer-in- charge. the joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per astm b221- 02. the material shall be such that it provides an expansion joints systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office buildings & complexes with no slipping down tendency amongst the components of the joint system. the joint system shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (material shall confirm to astm 6063). 18 wall joint of 100 mm gap 19 providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of engineer-in-charge. the joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per astm b221-02. the system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. system shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. the cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. the self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. the joint system shall resists damage or deterioration from the impact of falling ice, exposure to uv, airborne contaminants and occasional foot traffic from maintenance personnel. provision of moisture barrier membrane in the joint system to have water tight joint is mandatory requirement. (material shall confirm to astm 6063.) 20 roof joint of 100 mm gap 21 repairs to roof 22 repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (dr. fixit make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge.with cement mortar 1:4 (1 cement: 4 coarse sand) 23 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 24 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 25 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 26 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 27 asbestos cement sheet 28 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 29 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 30 repair to toilets + plumbing works 31 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 32 for thickness of tiles 10 mm to 25 mm 33 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 34 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 35 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 36 providing and filling of cinder in sunken portion. 37 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 38 75 to 80 mm dia pipe 39 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 40 15 mm to 40 mm nominal bore 41 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 42 up to 150 mm diameter 43 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 44 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 45 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 46 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 47 rectangular manhole 90x80 cm and 45 cm deep 48 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 49 110 mm diameter 50 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 51 a) coupler 52 110 mm 53 b) bend 87.5° 54 110 mm bend 55 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 56 75 mm diameter pipes 57 100 mm diameter pipes 58 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 59 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 60 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 61 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 62 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 63 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 64 a) 32mm dia (for wash basin) 65 b) 40mm dia (for sink and urinal) 66 providing & fixing c.p. brass waste coupling for pvc waste pipe. 67 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 68 110 mm dia (wall thickness - 3.2 to 3.8 mm) 69 75 mm dia (wall thickness - 3.2 to 3.8 mm) 70 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 71 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 72 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 73 p-trap type floor trap 110 x 75 mm 74 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 75 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 76 providing and fixing 100 mm sand cast iron grating for gully trap. 77 providing & fixing soil, waste and vent pipes. 78 a) 100mm dia centrifugally cast iron s & s pipe. 79 b)75mm dia centrifugally cast iron s & s pipe. 80 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 81 a) for 100mm dia pipe. 82 b) for 75mm dia pipe. 83 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 84 a) 100mm 85 sand cast iron s&s as per is - 3989 86 b) 75mm 87 sand cast iron s&s as per is- 3989 88 providing and fixing plaincast iron s & s sanitary bend. 89 a) 100mm 90 sand cast iron s&s as per is - 1729 91 b) 75mm 92 sand cast iron s&s as per is - 3989 93 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 94 a) 100x100x100mm 95 b) 75x75x75mm 96 providing and fixingcast iron terminal guard. 97 a) 100mm 98 b) 75mm 99 providing & fixingcast iron coller. 100 a)100 mm 101 sand cast iron s&s as per is - 3989 102 b)75mm dia. 103 sand cast iron s&s as per is - 3989 104 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 105 a) 100mm 106 b) 75mm 107 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 108 a) 100mm inlet & 75mm outlet. 109 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 110 providing and fixing ptmt urinal cock of approved quality and colour. 111 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 112 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 113 15 mm nominal outer dia pipes 114 20 mm nominal outer dia pipes 115 25 mm nominal outer dia pipes 116 32 mm nominal outer dia pipes 117 providing and fixing brass stop cock of approved quality. 118 15 mm nominal bore 119 providing and fixing gun metal gate valve with wheel of approved quality. 120 a) 25mm dia nominal bore 121 b) 32mm dia nominal bore 122 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 123 a) 25mm. nominal bore 124 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 125 a) 15mm nominal bore 126 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 127 a) 15mm nominal bore 128 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 129 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 130 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 131 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 132 providing & fixing cp brass bib cock of approved quality conforming to is 8931 133 a) 15mm nominal bore 134 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 135 a) 15mm nominal bore 136 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 137 15mm nominal bore 138 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 139 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 140 25mm nominal bore, weighing not less than 62 gms 141 cutting holes up to 30x30 cm in walls including making good the same: 142 with common burnt clay f.p.s. (non modular) bricks 143 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 144 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 145 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 146 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 147 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 148 repair to plaster and plinth protection 149 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge.nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 150 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 151 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 152 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 153 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 154 with cement mortar 1:4 (1cement: 4 coarse sand) 155 12mm cement plaster of mix : 156 1:6 (1 cement : 6 course sand) 157 6mm cement plaster to ceiling of mix : 158 1:3 ( 1 cement : 3 fine sand) 159 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 160 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 161 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 162 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 163 old work (one or more coats) 164 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 165 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 166 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 167 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 168 repairs to door / windows 169 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 170 of area 3 sq. metres and below 171 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 172 of area 3 sq. metres and below 173 renewing glass panes, with putty and nails wherever necessary including racking out the old putty:float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 174 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 175 35 mm thick including isi marked stainless steel butt hinges with necessary screws 176 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 177 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete 178 fixed to steel windows by welding 179 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 180 300 mm weighing not less than 200gms. 181 250 mm weighing not less than 150gms. 182 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 183 100x58x1.90 mm 184 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 185 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 186 300 x 10mm 187 200 x 10mm 188 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 189 125 mm 190 providing and fixing factory made pvc door shutter made of solid foam pvc profiles of thickness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top / bottom / lock) rails of minimum cross section of 70mm x 28mm, of shape and design as per manufacturers specifications having homogenous fine cellular structure and smooth integral outer skin, inserted with g.l. c section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stiffeners as per manufacturers specifications mitered cut joints for styles and rails provided with telescopic polymeric l corners are joined together using solvent adhesive and strengthened with fully threaded stainless steel screws (of required size) through reinforcement stiffener with paneling of specified solid foam pvc board / high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam pvc moulded headings of required size using pvc solvent adhesive / cement. the finished door shutter including ss hardware, 1 no. ss sliding door bolt 200 x 10mm, 1 no. ss tower bolt 200 x 10mm and 2 nos. ss handles 125 mm, shall be fixed to frame with 3 nos. stainless steel hinges of minimum size 100x58x1.9mm and stainless steel screws of required size complete as per direction of the engineer-in-charge.(cost of above hardware is inclusive in rates) 5 mm thick solid foam pvc panel of required size with moulded/extruded beading of appropriate design shape and size as per manufacturers specifications (to secure the panel insert tight in place within the style and rails of the shutter)matching the color &shade of shutter frame - non decorative type. 191 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 192 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 193 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 194 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 195 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 196 4.0 mm thick glass panes 197 applying priming coat : 198 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 199 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 200 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 201 two or more coats on new work 202 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 203 one or more coats on old work 204 repairs to flooring 205 miscellaneous 206 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 207 in cement mortar 208 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 209 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) : 3 graded stone aggregate 20 mm nominal size). 210 centering and shuttering including strutting, propping etc. and removal of form for all heights : 211 edges of slabs and breaks in floors and walls 212 under 20 cm wide 213 centering and shuttering including strutting, propping etc. and removal of form for all heights : 214 suspended floors, roofs, landings, balconies and access platform. 215 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 216 thermo-mechanically treated bars of grade fe-500d or more. 217 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 218 cement mortar 1:6 (1 cement : 6 coarse sand) 219 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 220 cement mortar 1:4 (1 cement :4 coarse sand 221 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 222 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 223 electrical work of school building 224 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 225 group c 226 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 227 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 228 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 229 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 230 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 231 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 232 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 233 group c 234 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 235 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 236 2 x 1.5 sq. mm 237 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 32 mm 240 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 241 100 mm x 100 mm x 60 mm deep 242 150 mm x 75 mm x 60 mm deep 243 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 244 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 245 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 246 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 247 supplying and fixing brass batten/ angle holder including connection etc. as required. 248 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 249 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 250 6 way, double door 251 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 252 4 way (4 + 12), double door 253 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 254 single pole 255 single pole and neutral 256 triple pole 257 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 258 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 259 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 260 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/ coke and salt as required. 261 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 262 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 263 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 264 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 265 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 266 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover 3on the fan box etc. as required. 267 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 268 upto 450 mm sweep 269 supply of 15w surface mounted round led with all accessories as per standard item.. 270 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 271 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 272 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 273 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 274 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 275 450 mm sweep 1400 rpm 276 lightning conductor 277 providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, g.i. tube, having single prong at top, with 85 mm dia 6 mm thick g.i. base plate including holes etc. complete as required. 278 fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 279 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 280 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 281 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 282 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 283 providing and fixing testing joint, made of 20 mm x 3 mm thick g.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chuck nuts and spring washers etc. complete as required. 284 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. details of cost for one set 285 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 286 bill of quantity for boys dinning hall 287 repairs to roof 288 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 289 asbestos cement sheet 290 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 291 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 292 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 293 repair to plaster and plinth protection 294 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 295 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 296 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 297 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 298 with cement mortar 1:4 (1cement: 4 coarse sand) 299 12mm cement plaster of mix : 300 1:6 (1 cement : 6 course sand) 301 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 302 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 303 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 304 old work (one or more coats) 305 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 306 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 307 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 308 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 309 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 310 repairs to door / windows 311 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 312 of area 3 sq. metres and below 313 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 314 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 315 renewal of old putty of glass panes (length) 316 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 317 35 mm thick including isi marked stainless steel butt hinges with necessary screws 318 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 319 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 320 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 321 300 mm weighing not less than 200gms. 322 250 mm weighing not less than 150gms. 323 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 324 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 325 300 x 10mm 326 150 x 10mm 327 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 328 with 12 mm mild steel u beading 329 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 330 125 mm 331 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 332 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 333 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 334 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 335 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 336 4.0 mm thick glass panes 337 applying priming coat : 338 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 339 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 340 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 341 two or more coats on new work 342 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 343 one or more coats on old work 344 flooring 345 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 346 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 347 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 348 25 mm thick 349 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 350 miscellaneous 351 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 352 in cement mortar 353 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 354 cement mortar 1:6 (1 cement : 6 coarse sand) 355 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 356 75 to 80 mm dia pipe 357 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 358 110 mm diameter 359 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 360 a) coupler 361 110 mm 362 b) bend 87.5° 363 110 mm bend 364 kitchen & dinning 365 structural repair & retrofitting 366 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 367 50mm average thickness 368 25 mm average thickness 369 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 370 bars upto 12 mm diameter 371 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 372 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 373 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 374 25mm thick in grade m 25 with cement content not less than 330 kg per cum 375 50mm thick in grade m 25 with cement content not less than 330 kg per cum 376 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 377 repairs to roof 378 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 379 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 380 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 381 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 382 asbestos cement sheet 383 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 384 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 385 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 386 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 387 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 388 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.electric resistance or induction butt welded tubes. 389 repair to toilets + plumbing works 390 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 391 for thickness of tiles 10 mm to 25 mm 392 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 393 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 394 plumbing work 395 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 396 75 to 80 mm dia pipe 397 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 398 15 mm to 40 mm nominal bore 399 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 400 up to 150 mm diameter 401 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 402 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 403 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 404 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 405 rectangular manhole 90x80 cm and 45 cm deep 406 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 407 110 mm diameter 408 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 409 a) coupler 410 110 mm 411 b) bend 87.5° 412 110 mm bend 413 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 414 75 mm diameter pipes 415 100 mm diameter pipes 416 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 417 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 418 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 419 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 420 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 421 a) 32mm dia (for wash basin) 422 b) 40mm dia (for sink and urinal) 423 providing & fixing c.p. brass waste coupling for pvc waste pipe. 424 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 425 110 mm dia (wall thickness - 3.2 to 3.8 mm) 426 75 mm dia (wall thickness - 3.2 to 3.8 mm) 427 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 428 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 429 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 430 p-trap type floor trap 110 x 75 mm 431 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 432 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 433 providing and fixing 100 mm sand cast iron grating for gully trap. 434 providing & fixing soil, waste and vent pipes. 435 a) 100mm dia centrifugally cast iron s & s pipe. 436 b)75mm dia centrifugally cast iron s & s pipe. 437 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 438 a) for 100mm dia pipe. 439 b) for 75mm dia pipe. 440 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 441 a) 100mm 442 sand cast iron s&s as per is - 3989 443 b) 75mm 444 sand cast iron s&s as per is- 3989 445 providing and fixing plaincast iron s & s sanitary bend. 446 a) 100mm 447 sand cast iron s&s as per is - 1729 448 b) 75mm 449 sand cast iron s&s as per is - 3989 450 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 451 a) 100x100x100mm 452 b) 75x75x75mm 453 providing and fixingcast iron terminal guard. 454 a) 100mm 455 b) 75mm 456 providing & fixingcast iron coller. 457 a)100 mm 458 sand cast iron s&s as per is - 3989 459 b)75mm dia. 460 sand cast iron s&s as per is - 3989 461 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 462 a) 100mm 463 b) 75mm 464 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 465 a) 100mm inlet & 75mm outlet. 466 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 467 providing and fixing ptmt urinal cock of approved quality and colour. 468 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 469 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 470 15 mm nominal outer dia pipes 471 20 mm nominal outer dia pipes 472 25 mm nominal outer dia pipes 473 32 mm nominal outer dia pipes 474 providing and fixing brass stop cock of approved quality. 475 15 mm nominal bore 476 providing and fixing gun metal gate valve with wheel of approved quality. 477 a) 25mm dia nominal bore 478 b) 32mm dia nominal bore 479 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 480 a) 25mm. nominal bore 481 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 482 a) 15mm nominal bore 483 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 484 a) 15mm nominal bore 485 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 486 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 487 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 488 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 489 providing & fixing cp brass bib cock of approved quality conforming to is 8931 490 a) 15mm nominal bore 491 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 492 a) 15mm nominal bore 493 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 494 15mm nominal bore 495 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 496 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 497 25mm nominal bore, weighing not less than 62 gms 498 cutting holes up to 30x30 cm in walls including making good the same: 499 with common burnt clay f.p.s. (non modular) bricks 500 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 501 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 502 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 503 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 504 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 505 repair to plaster and plinth protection 506 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 507 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 508 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 509 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 510 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 511 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 512 with cement mortar 1:4 (1cement: 4 coarse sand) 513 12mm cement plaster of mix : 514 1:6 (1 cement : 6 course sand) 515 6mm cement plaster to ceiling of mix : 516 1:3 ( 1 cement : 3 fine sand) 517 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 518 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 519 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 520 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 521 old work (one or more coats) 522 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 523 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 524 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 525 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 526 repairs to door / windows 527 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 528 of area 3 sq. metres and below 529 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 530 of area 3 sq. metres and below 531 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 532 float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 533 renewal of old putty of glass panes (length) 534 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 535 35 mm thick including isi marked stainless steel butt hinges with necessary screws 536 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 537 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 538 300 mm weighing not less than 200gms. 539 250 mm weighing not less than 150gms. 540 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 541 100x58x1.90 mm 542 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 543 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 544 300 x 10mm 545 200 x 10mm 546 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 547 125 mm 548 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 549 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (puf) /polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 550 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 551 with 12 mm mild steel u beading 552 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 553 using flats 30x6mm for diagonal braces and central cross piece 554 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 555 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 556 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size). 557 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 558 4.0 mm thick glass panes 559 applying priming coat : 560 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 561 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 562 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 563 two or more coats on new work 564 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 565 one or more coats on old work 566 miscellaneous 567 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 568 in cement mortar 569 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 570 cement mortar 1:6 (1 cement : 6 coarse sand) 571 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement : 572 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) : 3 graded stone aggregate 20 mm nominal size). 573 centering and shuttering including strutting, propping etc. and removal of form for all heights : 574 edges of slabs and breaks in floors and walls 575 under 20 cm wide 576 centering and shuttering including strutting, propping etc. and removal of form for all heights : 577 suspended floors, roofs, landings, balconies and access platform. 578 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 579 thermo-mechanically treated bars of grade fe-500d or more. 580 electrical work of kitchen & dinning 581 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 582 group c 583 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 584 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 585 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 586 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 587 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 588 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 589 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 590 group c 591 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 592 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 593 2 x 1.5 sq. mm 594 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 595 25 mm 596 32 mm 597 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 598 100 mm x 100 mm x 60 mm deep 599 150 mm x 75 mm x 60 mm deep 600 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 601 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 602 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 603 supplying and fixing brass batten/ angle holder including connection etc. as required. 604 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 605 4 way (4 + 12), double door 606 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 607 single pole 608 single pole and neutral 609 triple pole 610 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 611 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 612 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 613 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/ coke and salt as required. 614 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 615 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 616 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 617 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 618 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 619 supply of 15w surface mounted round led with all accessories as per standard item.. 620 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 621 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 622 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 623 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 624 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 625 450 mm sweep 1400 rpm 626 cost of mp hall 627 structural repair & retrofitting 628 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 629 50 mm average thickness 630 25 mm average thickness 631 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 632 bars upto 12 mm diameter 633 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 634 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 635 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 636 25mm thick in grade m 25 with cement content not less than 330 kg per cum 637 50mm thick in grade m 25 with cement content not less than 330 kg per cum 638 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 639 repairs to roof 640 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 641 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 642 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 643 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 644 asbestos cement sheet 645 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 646 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 647 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 648 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 649 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 650 repair to plaster and plinth protection 651 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 652 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 653 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 654 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 655 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 656 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 657 with cement mortar 1:4 (1cement: 4 coarse sand) 658 12mm cement plaster of mix : 659 1:6 (1 cement : 6 course sand) 660 6mm cement plaster to ceiling of mix : 661 1:3 ( 1 cement : 3 fine sand) 662 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 663 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 664 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 665 old work (one or more coats) 666 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 667 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 668 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 669 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 670 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 671 repairs to door / windows 672 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 673 of area 3 sq. metres and below 674 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 675 of area 3 sq. metres and below 676 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 677 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 678 renewal of old putty of glass panes (length) 679 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 680 35 mm thick including isi marked stainless steel butt hinges with necessary screws 681 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 682 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 683 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 684 300 mm weighing not less than 200gms. 685 250 mm weighing not less than 150gms. 686 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 687 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 688 300 x 10mm 689 150 x 10mm 690 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 691 with 12 mm mild steel u beading 692 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 693 125 mm 694 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 695 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 696 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 697 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 698 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 699 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 700 4.0 mm thick glass panes 701 applying priming coat : 702 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 703 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 704 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 705 two or more coats on new work 706 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 707 one or more coats on old work 708 flooring 709 miscellaneous 710 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 711 in cement mortar 712 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 713 cement mortar 1:6 (1 cement : 6 coarse sand) 714 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 715 cement mortar 1:4 (1 cement :4 coarse sand 716 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 717 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 718 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 719 75 to 80 mm dia pipe 720 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 721 110 mm diameter 722 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 723 a) coupler 724 110 mm 725 b) bend 87.5° 726 110 mm bend 727 electrical work 728 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 729 group c 730 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 731 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 732 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 733 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 734 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 735 2 x 1.5 sq. mm 736 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 737 25 mm 738 32 mm 739 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 740 100 mm x 100 mm x 60 mm deep 741 150 mm x 75 mm x 60 mm deep 742 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 743 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 744 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 745 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 746 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 747 6 way, double door 748 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 749 4 way (4 + 12), double door 750 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 751 single pole 752 single pole and neutral 753 triple pole 754 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 755 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 756 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 757 upto 450 mm sweep 758 supply of 15w surface mounted round led with all accessories as per standard item.. 759 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 760 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 761 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 762 supply of 30w led recess mounted fixturemake-philips cat no.rc380b led30s-6500 l60w60 psd od s1 or equivalent. 763 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 764 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 765 450 mm sweep 1400 rpm 766 boysdormitory (g) for 72 students 767 structural repair & retrofitting 768 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 769 50 mm average thickness 770 25 mm average thickness 771 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 772 bars upto 12 mm diameter 773 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 774 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 775 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 776 25mm thick in grade m 25 with cement content not less than 330 kg per cum 777 50mm thick in grade m 25 with cement content not less than 330 kg per cum 778 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 779 expansion joint treatment 780 providing and fixing of expansion joint system related with floor location as per drawings and direction of engineer-in-charge. the joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per astm b221-02. the system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. system shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. the cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. the self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. provision of moisture barrier membrane in the joint system to have watertight joint is mandatory requirement all as per the manufactures design and as approved by engineer -in- charge. (material shall confirm to astm 6063). 781 floor joint of 100 mm gap 782 providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of engineer-in- charge. the joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per astm b221- 02. the material shall be such that it provides an expansion joints systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office buildings & complexes with no slipping down tendency amongst the components of the joint system. the joint system shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (material shall confirm to astm 6063). 783 wall joint of 100 mm gap 784 providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of engineer-in-charge. the joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per astm b221-02. the system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. system shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. the cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. the self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. the joint system shall resists damage or deterioration from the impact of falling ice, exposure to uv, airborne contaminants and occasional foot traffic from maintenance personnel. provision of moisture barrier membrane in the joint system to have water tight joint is mandatory requirement. (material shall confirm to astm 6063.) 785 roof joint of 100 mm gap 786 repairs to roof 787 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 788 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 789 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 790 repair to toilets 791 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 792 nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 793 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 794 for thickness of tiles 10 mm to 25 mm 795 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 796 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 797 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 798 providing and filling of cinder in sunken portions. 799 repair to plaster and plinth protection 800 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 801 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 802 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 803 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 804 with cement mortar 1:4 (1cement: 4 coarse sand) 805 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 806 15mm cement plaster on rough side of single or half brick wall of mix 807 1:6 (1 cement : 6 course sand) 808 6mm cement plaster to ceiling of mix : 809 1:3 ( 1 cement : 3 fine sand) 810 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 811 two coats 812 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 813 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 814 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 815 washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of engineer-in-charge (payment for providing grooves shall be made separately). 816 forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the engineer-in-charge : 817 15 mm wide and 15 mm deep groove 818 repairs to door / windows 819 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 820 of area 3 sq. metres and below 821 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 822 of area 3 sq. metres and below 823 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 824 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 825 renewal of old putty of glass panes (length) 826 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 827 35 mm thick including isi marked stainless steel butt hinges with necessary screws 828 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 829 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete .fixed to steel windows by welding 830 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 831 300 mm weighing not less than 200gms. 832 250 mm weighing not less than 150gms. 833 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 834 100x58x1.90 mm 835 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 836 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 837 300 x 10mm 838 150 x 10mm 839 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 840 125 mm 841 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 842 twin rubber stopper 843 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 844 providing and fixing to existing door frames. 845 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 846 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4mm in both directions for doors, windows and clerestory windows with necessary screws : 847 35 mm thick shutters.with isi marked stainless steel butt hinges of required size. kiln seasoned and chemically treated hollock wood. 848 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 849 with 12 mm mild steel u beading 850 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 851 using flats 30x6mm for diagonal braces and central cross piece 852 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 853 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 854 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 855 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 856 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 857 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 858 steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 859 in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 860 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 861 4.0 mm thick glass panes 862 applying priming coat : 863 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 864 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 865 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 866 two or more coats on new work 867 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 868 one or more coats on old work 869 repairs to flooring 870 miscellaneous 871 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 872 in cement mortar 873 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 874 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 875 cement mortar 1:6 (1 cement : 6 coarse sand) 876 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 877 cement mortar 1:4 (1 cement :4 coarse sand 878 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 879 plumbing work of boysdormitory (g) for 72 students 880 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 881 75 to 80 mm dia pipe 882 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 883 15 mm to 40 mm nominal bore 884 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 885 up to 150 mm diameter 886 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 887 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 888 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 889 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 890 up to 150 mm diameter 891 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 892 rectangular manhole 90x80 cm and 45 cm deep 893 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 894 110 mm diameter 895 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 896 a) coupler 897 110 mm 898 b) bend 87.5° 899 110 mm bend 900 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 901 75 mm diameter pipes 902 100 mm diameter pipes 903 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 904 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 905 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 906 w.c. pan with isi marked white solid plastic seat and lid 907 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 908 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 909 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 910 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 911 a) 32mm dia (for wash basin) 912 b) 40mm dia (for sink and urinal) 913 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 914 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 915 providing & fixing c.p. brass waste coupling for pvc waste pipe. 916 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 917 110 mm dia (wall thickness - 3.2 to 3.8 mm) 918 75 mm dia (wall thickness - 3.2 to 3.8 mm) 919 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 920 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 921 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 922 p-trap type floor trap 110 x 75 mm 923 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 924 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 925 providing and fixing 100 mm sand cast iron grating for gully trap. 926 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 927 providing and fixing toilet paper holder : 928 vitreous china 929 providing & fixing soil, waste and vent pipes. 930 a) 100mm dia centrifugally cast iron s & s pipe. 931 b)75mm dia centrifugally cast iron s & s pipe. 932 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 933 a) for 100mm dia pipe. 934 b) for 75mm dia pipe. 935 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 936 a) 100mm 937 sand cast iron s&s as per is - 3989 938 b) 75mm 939 sand cast iron s&s as per is- 3989 940 providing and fixing plaincast iron s & s sanitary bend. 941 a) 100mm 942 sand cast iron s&s as per is - 1729 943 b) 75mm 944 sand cast iron s&s as per is - 3989 945 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 946 a) 100x100x100mm 947 b) 75x75x75mm 948 providing and fixingcast iron terminal guard. 949 a) 100mm 950 b) 75mm 951 providing & fixingcast iron coller. 952 a)100 mm 953 sand cast iron s&s as per is - 3989 954 b)75mm dia. 955 sand cast iron s&s as per is - 3989 956 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 957 a) 100mm 958 b) 75mm 959 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 960 a) 100mm inlet & 75mm outlet. 961 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 962 providing and fixing ptmt urinal cock of approved quality and colour. 963 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 964 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 965 15 mm nominal outer dia pipes 966 20 mm nominal outer dia pipes 967 25 mm nominal outer dia pipes 968 32 mm nominal outer dia pipes 969 providing and fixing brass stop cock of approved quality. 970 15 mm nominal bore 971 providing and fixing gun metal gate valve with wheel of approved quality. 972 a) 25mm dia nominal bore 973 b) 32mm dia nominal bore 974 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 975 a) 25mm. nominal bore 976 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 977 a) 15mm nominal bore 978 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 979 a) 15mm nominal bore 980 providing & fixing cp brass bib cock of approved quality conforming to is 8931 981 a) 15mm nominal bore 982 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 983 a) 15mm nominal bore 984 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 985 15mm nominal bore 986 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 987 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 988 25mm nominal bore, weighing not less than 62 gms 989 cutting holes up to 30x30 cm in walls including making good the same: 990 with common burnt clay f.p.s. (non modular) bricks 991 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 992 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 993 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 994 electrical work of boysdormitory (g) for 72 students 995 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 996 group b 997 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 998 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 999 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1000 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1001 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1002 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1003 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1004 group b 1005 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1006 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1007 2 x 1.5 sq. mm 1008 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1009 25 mm 1010 32 mm 1011 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1012 100 mm x 100 mm x 60 mm deep 1013 150 mm x 75 mm x 60 mm deep 1014 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1015 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1016 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1017 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1018 supplying and fixing brass batten/ angle holder including connection etc. as required. 1019 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1020 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1021 6 way, double door 1022 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1023 4 way (4 + 12), double door 1024 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1025 single pole 1026 single pole and neutral 1027 triple pole 1028 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1029 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1030 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1031 supply of 15w surface mounted round led with all accessories as per standard item.. 1032 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1033 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1034 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1035 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 1036 girls dormitories(cpwd type) 1 block 1037 structural repair & retrofitting 1038 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1039 50mm average thickness 1040 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1041 bars upto 12 mm diameter 1042 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1043 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1044 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1045 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1046 repairs to roof 1047 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1048 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1049 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1050 repair to toilets 1051 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1052 for thickness of tiles 10 mm to 25 mm 1053 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1054 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1055 repair to plaster and plinth protection 1056 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. 1057 two or more coats on new work 1058 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1059 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1060 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1061 15mm cement plaster on rough side of single or half brick wall of mix 1062 1:6 (1 cement : 6 course sand) 1063 6mm cement plaster to ceiling of mix : 1064 1:3 ( 1 cement : 3 fine sand) 1065 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1066 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1067 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1068 old work (one or more coats) 1069 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1070 washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of engineer-in-charge (payment for providing grooves shall be made separately). 1071 forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the engineer-in-charge : 1072 15 mm wide and 15 mm deep groove 1073 repairs to door / windows 1074 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1075 of area 3 sq. metres and below 1076 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1077 of area 3 sq. metres and below 1078 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 1079 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1080 renewal of old putty of glass panes (length) 1081 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete .fixed to steel windows by welding 1082 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1083 250 mm weighing not less than 150gms. 1084 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1085 100x58x1.90 mm 1086 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1087 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1088 300 x 10mm 1089 150 x 10mm 1090 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1091 125 mm 1092 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1093 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1094 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1095 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including isi marked stainless steel butt hinges with necessary screws 1096 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1.5 mm thick. 1097 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 1098 with 12 mm mild steel u beading 1099 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1100 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1101 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 1102 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1103 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1104 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1105 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1106 4.0 mm thick glass panes 1107 applying priming coat : 1108 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1109 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1110 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1111 two or more coats on new work 1112 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1113 one or more coats on old work 1114 miscellaneous 1115 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 1116 in cement mortar 1117 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1118 cement mortar 1:6 (1 cement : 6 coarse sand) 1119 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1120 cement mortar 1:4 (1 cement :4 coarse sand 1121 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1122 plumbing work of girlsdormitory (g) for 48 students 1123 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1124 75 to 80 mm dia pipe 1125 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1126 15 mm to 40 mm nominal bore 1127 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1128 up to 150 mm diameter 1129 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1130 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1131 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1132 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1133 up to 150 mm diameter 1134 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1135 rectangular manhole 90x80 cm and 45 cm deep 1136 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1137 110 mm diameter 1138 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1139 a) coupler 1140 110 mm 1141 b) bend 87.5° 1142 110 mm bend 1143 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1144 75 mm diameter pipes 1145 100 mm diameter pipes 1146 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1147 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1148 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1149 w.c. pan with isi marked white solid plastic seat and lid 1150 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1151 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1152 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1153 a) 32mm dia (for wash basin) 1154 b) 40mm dia (for sink and urinal) 1155 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 1156 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1157 providing & fixing c.p. brass waste coupling for pvc waste pipe. 1158 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1159 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1160 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1161 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1162 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1163 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1164 p-trap type floor trap 110 x 75 mm 1165 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1166 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1167 providing and fixing 100 mm sand cast iron grating for gully trap. 1168 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1169 providing and fixing toilet paper holder : 1170 vitreous china 1171 providing & fixing soil, waste and vent pipes. 1172 a) 100mm dia centrifugally cast iron s & s pipe. 1173 b)75mm dia centrifugally cast iron s & s pipe. 1174 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1175 a) for 100mm dia pipe. 1176 b) for 75mm dia pipe. 1177 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1178 a) 100mm 1179 sand cast iron s&s as per is - 3989 1180 b) 75mm 1181 sand cast iron s&s as per is- 3989 1182 providing and fixing plaincast iron s & s sanitary bend. 1183 a) 100mm 1184 sand cast iron s&s as per is - 1729 1185 b) 75mm 1186 sand cast iron s&s as per is - 3989 1187 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1188 a) 100x100x100mm 1189 b) 75x75x75mm 1190 providing and fixingcast iron terminal guard. 1191 a) 100mm 1192 b) 75mm 1193 providing & fixingcast iron coller. 1194 a)100 mm 1195 sand cast iron s&s as per is - 3989 1196 b)75mm dia. 1197 sand cast iron s&s as per is - 3989 1198 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1199 a) 100mm 1200 b) 75mm 1201 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1202 a) 100mm inlet & 75mm outlet. 1203 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1204 15 mm nominal outer dia pipes 1205 20 mm nominal outer dia pipes 1206 25 mm nominal outer dia pipes 1207 32 mm nominal outer dia pipes 1208 providing and fixing brass stop cock of approved quality. 1209 15 mm nominal bore 1210 providing and fixing gun metal gate valve with wheel of approved quality. 1211 a) 25mm dia nominal bore 1212 b) 32mm dia nominal bore 1213 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1214 a) 25mm. nominal bore 1215 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1216 a) 15mm nominal bore 1217 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1218 a) 15mm nominal bore 1219 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1220 a) 15mm nominal bore 1221 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1222 a) 15mm nominal bore 1223 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1224 15mm nominal bore 1225 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1226 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1227 25mm nominal bore, weighing not less than 62 gms 1228 cutting holes up to 30x30 cm in walls including making good the same: 1229 with common burnt clay f.p.s. (non modular) bricks 1230 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1231 electrical work of girlsdormitory (g) for 48 students 1232 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1233 group b 1234 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1235 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1236 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1237 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1238 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1239 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1240 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1241 group b 1242 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1243 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1244 2 x 1.5 sq. mm 1245 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1246 25 mm 1247 32 mm 1248 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1249 100 mm x 100 mm x 60 mm deep 1250 150 mm x 75 mm x 60 mm deep 1251 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1252 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1253 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1254 supplying and fixing brass batten/ angle holder including connection etc. as required. 1255 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1256 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1257 4 way (4 + 12), double door 1258 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1259 single pole 1260 single pole and neutral 1261 triple pole 1262 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1263 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1264 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1265 supply of 15w surface mounted round led with all accessories as per standard item.. 1266 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1267 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1268 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1269 staff qtrs type-iii . 1270 structural repair & retrofitting 1271 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1272 50 mm average thickness 1273 25 mm average thickness 1274 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1275 bars upto 12 mm diameter 1276 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1277 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1278 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1279 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1280 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1281 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 1282 repairs to roof 1283 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1284 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1285 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1286 repair to toilets 1287 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1288 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1289 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1290 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1291 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1292 providing and filling of cinder in sunken portions. 1293 repair to plaster and plinth protection 1294 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1295 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1296 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1297 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1298 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1299 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1300 with cement mortar 1:4 (1cement: 4 coarse sand) 1301 12mm cement plaster of mix : 1302 1:6 (1 cement : 6 course sand) 1303 6mm cement plaster to ceiling of mix : 1304 1:3 ( 1 cement : 3 fine sand) 1305 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1306 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1307 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1308 old work (one or more coats) 1309 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1310 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1311 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1312 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1313 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1314 repairs to door / windows 1315 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1316 of area 3 sq. metres and below 1317 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1318 of area 3 sq. metres and below 1319 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1320 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1321 renewal of old putty of glass panes (length) 1322 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1323 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1324 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1325 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1326 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1327 300 mm weighing not less than 200gms. 1328 250 mm weighing not less than 150gms. 1329 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1330 100x58x1.90 mm 1331 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1332 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1333 300 x 10mm 1334 150 x 10mm 1335 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 1336 providing and fixing to existing door frames. 1337 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1338 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1339 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1340 with isi marked stainless steel butt hinges of required size 1341 kiln seasoned and chemically treated hollock wood 1342 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1343 with 12 mm mild steel u beading 1344 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1345 125 mm 1346 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1347 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1348 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1349 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1350 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1351 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1352 4.0 mm thick glass panes 1353 applying priming coat : 1354 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1355 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1356 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1357 two or more coats on new work 1358 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1359 one or more coats on old work 1360 miscellaneous 1361 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1362 cement mortar 1:6 (1 cement : 6 coarse sand) 1363 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1364 cement mortar 1:4 (1 cement :4 coarse sand 1365 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1366 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1367 plumbing work of type-iii (g+1) 1368 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1369 75 to 80 mm dia pipe 1370 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1371 15 mm to 40 mm nominal bore 1372 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1373 up to 150 mm diameter 1374 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1375 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1376 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1377 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1378 up to 150 mm diameter 1379 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1380 rectangular manhole 90x80 cm and 45 cm deep 1381 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1382 110 mm diameter 1383 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1384 a) coupler 1385 110 mm 1386 b) bend 87.5° 1387 110 mm bend 1388 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1389 75 mm diameter pipes 1390 100 mm diameter pipes 1391 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1392 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1393 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1394 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1395 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1396 kitchen sink without drain board 1397 610x510 mm bowl depth 200 mm 1398 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1399 a) 32mm dia (for wash basin) 1400 b) 40mm dia (for sink and urinal) 1401 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1402 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1403 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1404 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1405 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1406 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1407 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1408 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1409 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1410 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1411 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1412 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1413 p-trap type floor trap 110 x 75 mm 1414 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1415 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1416 providing and fixing 100 mm sand cast iron grating for gully trap. 1417 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1418 providing & fixing soil, waste and vent pipes. 1419 a) 100mm dia centrifugally cast iron s & s pipe. 1420 b)75mm dia centrifugally cast iron s & s pipe. 1421 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1422 a) for 100mm dia pipe. 1423 b) for 75mm dia pipe. 1424 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1425 a) 100mm 1426 sand cast iron s&s as per is - 3989 1427 b) 75mm 1428 sand cast iron s&s as per is- 3989 1429 providing and fixing plaincast iron s & s sanitary bend. 1430 a) 100mm 1431 sand cast iron s&s as per is - 1729 1432 b) 75mm 1433 sand cast iron s&s as per is - 3989 1434 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1435 a) 100x100x100mm 1436 b) 75x75x75mm 1437 providing and fixingcast iron terminal guard. 1438 a) 100mm 1439 b) 75mm 1440 providing & fixingcast iron coller. 1441 a)100 mm 1442 sand cast iron s&s as per is - 3989 1443 b)75mm dia. 1444 sand cast iron s&s as per is - 3989 1445 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1446 a) 100mm 1447 b) 75mm 1448 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1449 a) 100mm inlet & 75mm outlet. 1450 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1451 15 mm nominal outer dia pipes 1452 20 mm nominal outer dia pipes 1453 25 mm nominal outer dia pipes 1454 32 mm nominal outer dia pipes 1455 providing and fixing brass stop cock of approved quality. 1456 15 mm nominal bore 1457 providing and fixing gun metal gate valve with wheel of approved quality. 1458 a) 25mm dia nominal bore 1459 b) 32mm dia nominal bore 1460 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1461 a) 25mm. nominal bore 1462 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1463 a) 15mm nominal bore 1464 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1465 a) 15mm nominal bore 1466 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1467 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1468 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1469 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1470 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1471 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1472 a) 15mm nominal bore 1473 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1474 a) 15mm nominal bore 1475 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1476 a) 15mm nominal bore 1477 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1478 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1479 25mm nominal bore, weighing not less than 62 gms 1480 cutting holes up to 30x30 cm in walls including making good the same: 1481 with common burnt clay f.p.s. (non modular) bricks 1482 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1483 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1484 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1485 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1486 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1487 electrical work of type-iii (g+1) 1488 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1489 group b 1490 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1491 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1492 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1493 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1494 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1495 xxxx 1496 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1497 group b 1498 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1499 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1500 2 x 1.5 sq. mm 1501 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1502 25 mm 1503 32 mm 1504 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1505 100 mm x 100 mm x 60 mm deep 1506 150 mm x 75 mm x 60 mm deep 1507 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1508 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1509 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1510 s/f light plug point modular type accessories :- 1511 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1512 s/f power plug point modular type accessories :- 1513 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1514 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1515 supplying and fixing brass batten/ angle holder including connection etc. as required. 1516 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1517 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1518 6 way, double door 1519 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1520 4 way (4 + 12), double door 1521 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1522 single pole 1523 single pole and neutral 1524 triple pole 1525 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1526 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1527 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1528 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1529 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1530 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1531 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1532 supply of 15w surface mounted round led with all accessories as per standard item.. 1533 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1534 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1535 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1536 staff qtrs type-iii . 1537 structural repair & retrofitting 1538 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1539 50 mm average thickness 1540 25 mm average thickness 1541 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1542 bars upto 12 mm diameter 1543 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1544 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1545 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1546 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1547 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1548 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 1549 repairs to roof 1550 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1551 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1552 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1553 repair to toilets 1554 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1555 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1556 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1557 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1558 repair to plaster and plinth protection 1559 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1560 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1561 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1562 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1563 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1564 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1565 with cement mortar 1:4 (1cement: 4 coarse sand) 1566 12mm cement plaster of mix : 1567 1:6 (1 cement : 6 course sand) 1568 6mm cement plaster to ceiling of mix : 1569 1:3 ( 1 cement : 3 fine sand) 1570 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1571 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1572 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1573 old work (one or more coats) 1574 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1575 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1576 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1577 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1578 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1579 repairs to door / windows 1580 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1581 of area 3 sq. metres and below 1582 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1583 of area 3 sq. metres and below 1584 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1585 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1586 renewal of old putty of glass panes (length) 1587 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1588 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1589 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1590 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1591 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1592 300 mm weighing not less than 200gms. 1593 250 mm weighing not less than 150gms. 1594 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1595 100x58x1.90 mm 1596 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1597 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1598 300 x 10mm 1599 150 x 10mm 1600 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 1601 providing and fixing to existing door frames. 1602 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1603 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1604 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1605 with isi marked stainless steel butt hinges of required size 1606 kiln seasoned and chemically treated hollock wood 1607 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1608 with 12 mm mild steel u beading 1609 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1610 125 mm 1611 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1612 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1613 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1614 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1615 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1616 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1617 4.0 mm thick glass panes 1618 applying priming coat : 1619 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1620 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1621 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1622 two or more coats on new work 1623 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1624 one or more coats on old work 1625 flooring 1626 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1627 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1628 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1629 25 mm thick 1630 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1631 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 1632 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 1633 miscellaneous 1634 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1635 cement mortar 1:6 (1 cement : 6 coarse sand) 1636 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1637 cement mortar 1:4 (1 cement :4 coarse sand 1638 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1639 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1640 plumbing work of type-iii (g) 1641 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1642 75 to 80 mm dia pipe 1643 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1644 15 mm to 40 mm nominal bore 1645 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1646 up to 150 mm diameter 1647 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1648 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1649 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1650 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1651 up to 150 mm diameter 1652 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1653 rectangular manhole 90x80 cm and 45 cm deep 1654 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1655 110 mm diameter 1656 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1657 a) coupler 1658 110 mm 1659 b) bend 87.5° 1660 110 mm bend 1661 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1662 75 mm diameter pipes 1663 100 mm diameter pipes 1664 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1665 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1666 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1667 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1668 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1669 kitchen sink without drain board 1670 610x510 mm bowl depth 200 mm 1671 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1672 a) 32mm dia (for wash basin) 1673 b) 40mm dia (for sink and urinal) 1674 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1675 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1676 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1677 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1678 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1679 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1680 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1681 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1682 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1683 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1684 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1685 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1686 p-trap type floor trap 110 x 75 mm 1687 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1688 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1689 providing and fixing 100 mm sand cast iron grating for gully trap. 1690 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1691 providing & fixing soil, waste and vent pipes. 1692 a) 100mm dia centrifugally cast iron s & s pipe. 1693 b)75mm dia centrifugally cast iron s & s pipe. 1694 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1695 a) for 100mm dia pipe. 1696 b) for 75mm dia pipe. 1697 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1698 a) 100mm 1699 sand cast iron s&s as per is - 3989 1700 b) 75mm 1701 sand cast iron s&s as per is- 3989 1702 providing and fixing plaincast iron s & s sanitary bend. 1703 a) 100mm 1704 sand cast iron s&s as per is - 1729 1705 b) 75mm 1706 sand cast iron s&s as per is - 3989 1707 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1708 a) 100x100x100mm 1709 b) 75x75x75mm 1710 providing and fixingcast iron terminal guard. 1711 a) 100mm 1712 b) 75mm 1713 providing & fixingcast iron coller. 1714 a)100 mm 1715 sand cast iron s&s as per is - 3989 1716 b)75mm dia. 1717 sand cast iron s&s as per is - 3989 1718 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1719 a) 100mm 1720 b) 75mm 1721 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1722 a) 100mm inlet & 75mm outlet. 1723 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1724 15 mm nominal outer dia pipes 1725 20 mm nominal outer dia pipes 1726 25 mm nominal outer dia pipes 1727 32 mm nominal outer dia pipes 1728 providing and fixing brass stop cock of approved quality. 1729 15 mm nominal bore 1730 providing and fixing gun metal gate valve with wheel of approved quality. 1731 a) 25mm dia nominal bore 1732 b) 32mm dia nominal bore 1733 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1734 a) 25mm. nominal bore 1735 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1736 a) 15mm nominal bore 1737 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1738 a) 15mm nominal bore 1739 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1740 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1741 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1742 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1743 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1744 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1745 a) 15mm nominal bore 1746 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1747 a) 15mm nominal bore 1748 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1749 a) 15mm nominal bore 1750 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1751 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1752 25mm nominal bore, weighing not less than 62 gms 1753 cutting holes up to 30x30 cm in walls including making good the same: 1754 with common burnt clay f.p.s. (non modular) bricks 1755 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1756 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1757 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1758 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1759 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1760 electrical work of type-iii (g) 1761 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1762 group b 1763 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1764 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1765 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1766 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1767 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1768 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1769 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1770 group b 1771 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1772 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1773 2 x 1.5 sq. mm 1774 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1775 25 mm 1776 32 mm 1777 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1778 100 mm x 100 mm x 60 mm deep 1779 150 mm x 75 mm x 60 mm deep 1780 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1781 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1782 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1783 s/f light plug point modular type accessories :- 1784 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1785 s/f power plug point modular type accessories :- 1786 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1787 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1788 supplying and fixing brass batten/ angle holder including connection etc. as required. 1789 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1790 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1791 6 way, double door 1792 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1793 4 way (4 + 12), double door 1794 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1795 single pole 1796 single pole and neutral 1797 triple pole 1798 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1799 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1800 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1801 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1802 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1803 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1804 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1805 supply of 15w surface mounted round led with all accessories as per standard item.. 1806 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1807 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1808 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1809 type-ii staff qtrs. 1810 structural repair & retrofitting 1811 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1812 25 mm average thickness 1813 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1814 bars upto 12 mm diameter 1815 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1816 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1817 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1818 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1819 repairs to roof 1820 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1821 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1822 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1823 repair to toilets 1824 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1825 for thickness of tiles 10 mm to 25 mm 1826 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1827 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1828 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1829 providing and filling of cinder in sunken portions. 1830 repair to plaster and plinth protection 1831 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1832 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1833 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1834 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1835 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1836 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1837 with cement mortar 1:4 (1cement: 4 coarse sand) 1838 15mm cement plaster of mix : 1839 1:6 (1 cement : 6 course sand) 1840 pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1841 raised and cut pointing 1842 6mm cement plaster to ceiling of mix : 1843 1:3 ( 1 cement : 3 fine sand) 1844 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1845 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1846 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1847 old work (one or more coats) 1848 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1849 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1850 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1851 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1852 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1853 repairs to door / windows 1854 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1855 of area 3 sq. metres and below 1856 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1857 of area 3 sq. metres and below 1858 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1859 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1860 renewal of old putty of glass panes (length) 1861 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1862 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1863 250 mm weighing not less than 150gms. 1864 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1865 100x58x1.90 mm 1866 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1867 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1868 300 x 10mm 1869 150 x 10mm 1870 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1871 125 mm 1872 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1873 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including isi marked stainless steel butt hinges with necessary screws 1874 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1.5 mm thick. 1875 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1876 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1877 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1878 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1879 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1880 4.0 mm thick glass panes 1881 applying priming coat : 1882 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1883 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1884 two or more coats on new work 1885 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1886 one or more coats on old work 1887 miscellaneous 1888 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1889 cement mortar 1:6 (1 cement : 6 coarse sand) 1890 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1891 cement mortar 1:4 (1 cement :4 coarse sand 1892 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1893 plumbing work 1894 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1895 75 to 80 mm dia pipe 1896 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1897 15 mm to 40 mm nominal bore 1898 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1899 up to 150 mm diameter 1900 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1901 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1902 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1903 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1904 up to 150 mm diameter 1905 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1906 rectangular manhole 90x80 cm and 45 cm deep 1907 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1908 110 mm diameter 1909 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1910 a) coupler 1911 110 mm 1912 b) bend 87.5° 1913 110 mm bend 1914 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1915 75 mm diameter pipes 1916 100 mm diameter pipes 1917 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1918 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1919 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1920 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1921 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1922 kitchen sink without drain board 1923 610x510 mm bowl depth 200 mm 1924 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1925 a) 32mm dia (for wash basin) 1926 b) 40mm dia (for sink and urinal) 1927 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1928 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1929 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1930 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1931 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1932 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1933 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1934 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1935 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1936 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1937 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1938 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1939 p-trap type floor trap 110 x 75 mm 1940 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1941 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1942 providing and fixing 100 mm sand cast iron grating for gully trap. 1943 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1944 providing & fixing soil, waste and vent pipes. 1945 a) 100mm dia centrifugally cast iron s & s pipe. 1946 b)75mm dia centrifugally cast iron s & s pipe. 1947 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1948 a) for 100mm dia pipe. 1949 b) for 75mm dia pipe. 1950 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1951 a) 100mm 1952 sand cast iron s&s as per is - 3989 1953 b) 75mm 1954 sand cast iron s&s as per is- 3989 1955 providing and fixing plaincast iron s & s sanitary bend. 1956 a) 100mm 1957 sand cast iron s&s as per is - 1729 1958 b) 75mm 1959 sand cast iron s&s as per is - 3989 1960 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1961 a) 100x100x100mm 1962 b) 75x75x75mm 1963 providing and fixingcast iron terminal guard. 1964 a) 100mm 1965 b) 75mm 1966 providing & fixingcast iron coller. 1967 a)100 mm 1968 sand cast iron s&s as per is - 3989 1969 b)75mm dia. 1970 sand cast iron s&s as per is - 3989 1971 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1972 a) 100mm 1973 b) 75mm 1974 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1975 a) 100mm inlet & 75mm outlet. 1976 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1977 15 mm nominal outer dia pipes 1978 20 mm nominal outer dia pipes 1979 25 mm nominal outer dia pipes 1980 32 mm nominal outer dia pipes 1981 providing and fixing brass stop cock of approved quality. 1982 15 mm nominal bore 1983 providing and fixing gun metal gate valve with wheel of approved quality. 1984 a) 25mm dia nominal bore 1985 b) 32mm dia nominal bore 1986 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1987 a) 25mm. nominal bore 1988 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1989 a) 15mm nominal bore 1990 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1991 a) 15mm nominal bore 1992 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1993 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1994 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1995 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1996 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1997 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1998 a) 15mm nominal bore 1999 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2000 a) 15mm nominal bore 2001 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2002 a) 15mm nominal bore 2003 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2004 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2005 25mm nominal bore, weighing not less than 62 gms 2006 cutting holes up to 30x30 cm in walls including making good the same: 2007 with common burnt clay f.p.s. (non modular) bricks 2008 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2009 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2010 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2011 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2012 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2013 electrical work 2014 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2015 group b 2016 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2017 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2018 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2019 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2020 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2021 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2022 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2023 group b 2024 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2025 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2026 2 x 1.5 sq. mm 2027 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2028 25 mm 2029 32 mm 2030 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2031 100 mm x 100 mm x 60 mm deep 2032 150 mm x 75 mm x 60 mm deep 2033 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2034 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2035 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2036 s/f light plug point modular type accessories :- 2037 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 2038 s/f power plug point modular type accessories :- 2039 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 2040 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2041 supplying and fixing brass batten/ angle holder including connection etc. as required. 2042 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2043 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2044 6 way, double door 2045 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2046 4 way (4 + 12), double door 2047 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2048 single pole 2049 single pole and neutral 2050 triple pole 2051 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2052 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2053 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2054 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2055 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2056 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2057 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2058 supply of 15w surface mounted round led with all accessories as per standard item.. 2059 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2060 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2061 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2062 staff qtrs type-i . 2063 structural repair & retrofitting 2064 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 2065 50 mm average thickness 2066 25 mm average thickness 2067 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 2068 bars upto 12 mm diameter 2069 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 2070 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 2071 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 2072 25mm thick in grade m 25 with cement content not less than 330 kg per cum 2073 50mm thick in grade m 25 with cement content not less than 330 kg per cum 2074 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 2075 repairs to roof 2076 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2077 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2078 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2079 repair to toilets 2080 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2081 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2082 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 2083 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2084 repair to plaster and plinth protection 2085 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2086 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2087 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2088 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2089 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2090 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2091 with cement mortar 1:4 (1cement: 4 coarse sand) 2092 12mm cement plaster of mix : 2093 1:6 (1 cement : 6 course sand) 2094 6mm cement plaster to ceiling of mix : 2095 1:3 ( 1 cement : 3 fine sand) 2096 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2097 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2098 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2099 old work (one or more coats) 2100 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2101 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2102 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2103 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2104 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2105 repairs to door / windows 2106 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2107 of area 3 sq. metres and below 2108 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2109 of area 3 sq. metres and below 2110 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2111 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2112 renewal of old putty of glass panes (length) 2113 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2114 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2115 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2116 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 2117 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2118 300 mm weighing not less than 200gms. 2119 250 mm weighing not less than 150gms. 2120 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 2121 100x58x1.90 mm 2122 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2123 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2124 300 x 10mm 2125 150 x 10mm 2126 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 2127 providing and fixing to existing door frames. 2128 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 2129 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2130 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2131 with isi marked stainless steel butt hinges of required size 2132 kiln seasoned and chemically treated hollock wood 2133 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2134 with 12 mm mild steel u beading 2135 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2136 125 mm 2137 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2138 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2139 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2140 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2141 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2142 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2143 4.0 mm thick glass panes 2144 applying priming coat : 2145 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 2146 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2147 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2148 two or more coats on new work 2149 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2150 one or more coats on old work 2151 flooring 2152 miscellaneous 2153 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2154 cement mortar 1:6 (1 cement : 6 coarse sand) 2155 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2156 cement mortar 1:4 (1 cement :4 coarse sand 2157 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2158 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2159 plumbing work of type-i (g) 2160 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2161 75 to 80 mm dia pipe 2162 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2163 15 mm to 40 mm nominal bore 2164 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2165 up to 150 mm diameter 2166 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2167 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2168 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2169 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2170 up to 150 mm diameter 2171 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2172 rectangular manhole 90x80 cm and 45 cm deep 2173 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2174 110 mm diameter 2175 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2176 a) coupler 2177 110 mm 2178 b) bend 87.5° 2179 110 mm bend 2180 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 2181 75 mm diameter pipes 2182 100 mm diameter pipes 2183 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2184 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2185 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2186 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2187 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2188 kitchen sink without drain board 2189 610x510 mm bowl depth 200 mm 2190 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2191 a) 32mm dia (for wash basin) 2192 b) 40mm dia (for sink and urinal) 2193 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2194 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2195 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2196 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2197 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 2198 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2199 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2200 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2201 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2202 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2203 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2204 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2205 p-trap type floor trap 110 x 75 mm 2206 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2207 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2208 providing and fixing 100 mm sand cast iron grating for gully trap. 2209 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2210 providing & fixing soil, waste and vent pipes. 2211 a) 100mm dia centrifugally cast iron s & s pipe. 2212 b)75mm dia centrifugally cast iron s & s pipe. 2213 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 2214 a) for 100mm dia pipe. 2215 b) for 75mm dia pipe. 2216 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 2217 a) 100mm 2218 sand cast iron s&s as per is - 3989 2219 b) 75mm 2220 sand cast iron s&s as per is- 3989 2221 providing and fixing plaincast iron s & s sanitary bend. 2222 a) 100mm 2223 sand cast iron s&s as per is - 1729 2224 b) 75mm 2225 sand cast iron s&s as per is - 3989 2226 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 2227 a) 100x100x100mm 2228 b) 75x75x75mm 2229 providing and fixingcast iron terminal guard. 2230 a) 100mm 2231 b) 75mm 2232 providing & fixingcast iron coller. 2233 a)100 mm 2234 sand cast iron s&s as per is - 3989 2235 b)75mm dia. 2236 sand cast iron s&s as per is - 3989 2237 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 2238 a) 100mm 2239 b) 75mm 2240 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 2241 a) 100mm inlet & 75mm outlet. 2242 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2243 15 mm nominal outer dia pipes 2244 20 mm nominal outer dia pipes 2245 25 mm nominal outer dia pipes 2246 32 mm nominal outer dia pipes 2247 providing and fixing brass stop cock of approved quality. 2248 15 mm nominal bore 2249 providing and fixing gun metal gate valve with wheel of approved quality. 2250 a) 25mm dia nominal bore 2251 b) 32mm dia nominal bore 2252 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2253 a) 25mm. nominal bore 2254 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2255 a) 15mm nominal bore 2256 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2257 a) 15mm nominal bore 2258 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2259 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2260 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2261 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2262 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2263 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2264 a) 15mm nominal bore 2265 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2266 a) 15mm nominal bore 2267 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2268 a) 15mm nominal bore 2269 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2270 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2271 25mm nominal bore, weighing not less than 62 gms 2272 cutting holes up to 30x30 cm in walls including making good the same: 2273 with common burnt clay f.p.s. (non modular) bricks 2274 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2275 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2276 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2277 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2278 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2279 electrical work of type-i (g) 2280 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2281 group b 2282 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2283 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2284 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2285 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2286 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2287 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2288 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2289 group b 2290 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2291 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2292 2 x 1.5 sq. mm 2293 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2294 25 mm 2295 32 mm 2296 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2297 100 mm x 100 mm x 60 mm deep 2298 150 mm x 75 mm x 60 mm deep 2299 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2300 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2301 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2302 s/f light plug point modular type accessories :- 2303 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 2304 s/f power plug point modular type accessories :- 2305 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 2306 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2307 supplying and fixing brass batten/ angle holder including connection etc. as required. 2308 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2309 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2310 6 way, double door 2311 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2312 4 way (4 + 12), double door 2313 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2314 single pole 2315 single pole and neutral 2316 triple pole 2317 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2318 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2319 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2320 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2321 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2322 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2323 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2324 supply of 15w surface mounted round led with all accessories as per standard item.. 2325 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2326 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2327 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2328 type-i (g) 5 units 2329 repairs to roof 2330 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 2331 asbestos cement sheet 2332 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 2333 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 2334 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, 2335 shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 2336 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 2337 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m* 2338 repairs to toilets 2339 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2340 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2341 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 2342 for thickness of tiles 10 mm to 25 mm 2343 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2344 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 2345 repair to plaster & plinth protection 2346 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2347 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2348 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2349 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2350 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2351 with cement mortar 1:4 (1cement: 4 coarse sand) 2352 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2353 12mm cement plaster of mix : 2354 1:6 (1 cement : 6 course sand) 2355 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2356 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2357 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2358 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2359 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2360 old work (one or more coats) 2361 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2362 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2363 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2364 repairs to door/windows 2365 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2366 of area 3 sq. metres and below 2367 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2368 of area 3 sq. metres and below 2369 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 2370 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2371 renewal of old putty of glass panes (length) 2372 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2373 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2374 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2375 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 2376 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2377 300 mm weighing not less than 200gms. 2378 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2379 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2380 300 x 10mm 2381 150 x 10mm 2382 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2383 125 mm 2384 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 2385 twin rubber stopper 2386 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2387 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2388 with isi marked stainless steel butt hinges of required size 2389 kiln seasoned and chemically treated hollock wood 2390 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2391 with 12 mm mild steel u beading 2392 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2393 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2394 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2395 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2396 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2397 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2398 4.0 mm thick glass panes 2399 applying priming coat : 2400 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 2401 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2402 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2403 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2404 one or more coats on old work 2405 miscellaneous 2406 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2407 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 2408 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 2409 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2410 cement mortar 1:6 (1 cement : 6 coarse sand) 2411 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2412 cement mortar 1:4 (1 cement :4 coarse sand 2413 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2414 plumbing work of type-i (g) 5 units 2415 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2416 15 mm to 40 mm nominal bore 2417 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2418 up to 150 mm diameter 2419 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2420 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2421 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2422 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 2423 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2424 up to 150 mm diameter 2425 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2426 rectangular manhole 90x80 cm and 45 cm deep 2427 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2428 110 mm diameter 2429 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2430 a) coupler 2431 110 mm 2432 b) bend 87.5° 2433 110 mm bend 2434 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2435 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2436 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2437 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2438 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2439 kitchen sink without drain board 2440 610x510 mm bowl depth 200 mm 2441 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2442 a) 32mm dia (for wash basin) 2443 b) 40mm dia (for sink and urinal) 2444 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2445 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2446 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2447 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2448 providing & fixing c.p. brass waste coupling for pvc waste pipe. 2449 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2450 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2451 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2452 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2453 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2454 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2455 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2456 p-trap type floor trap 110 x 75 mm 2457 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2458 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2459 providing and fixing 100 mm sand cast iron grating for gully trap. 2460 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2461 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2462 15 mm nominal outer dia pipes 2463 20 mm nominal outer dia pipes 2464 25 mm nominal outer dia pipes 2465 32 mm nominal outer dia pipes 2466 providing and fixing brass stop cock of approved quality. 2467 15 mm nominal bore 2468 providing and fixing gun metal gate valve with wheel of approved quality. 2469 a) 25mm dia nominal bore 2470 b) 32mm dia nominal bore 2471 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2472 a) 25mm. nominal bore 2473 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2474 a) 15mm nominal bore 2475 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2476 a) 15mm nominal bore 2477 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2478 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2479 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2480 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2481 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2482 a) 15mm nominal bore 2483 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2484 a) 15mm nominal bore 2485 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2486 a) 15mm nominal bore 2487 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2488 cutting holes up to 30x30 cm in walls including making good the same: 2489 with common burnt clay f.p.s. (non modular) bricks 2490 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2491 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2492 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2493 electrical work of type-i (g) 5 units 2494 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2495 group b 2496 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2497 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2498 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2499 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2500 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2501 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2502 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2503 group b 2504 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2505 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2506 2 x 1.5 sq. mm 2507 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2508 25 mm 2509 32 mm 2510 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2511 100 mm x 100 mm x 60 mm deep 2512 150 mm x 75 mm x 60 mm deep 2513 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2514 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2515 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2516 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2517 supplying and fixing brass batten/ angle holder including connection etc. as required. 2518 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2519 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2520 6 way, double door 2521 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2522 4 way (4 + 12), double door 2523 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2524 single pole 2525 single pole and neutral 2526 triple pole 2527 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2528 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2529 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2530 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2531 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2532 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2533 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2534 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover 3on the fan box etc. as required. 2535 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2536 upto 450 mm sweep 2537 supply of 15w surface mounted round led with all accessories as per standard item.. 2538 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2539 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2540 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2541 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2542 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2543 300 mm sweep 1300 rpm 2544 cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia pvc pipe conforming bis-12818 and making good the same etc. complete as per direction of engineer-in-charge. 2545 lightning conductor 2546 providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, g.i. tube, having single prong at top, with 85 mm dia 6 mm thick g.i. base plate including holes etc. complete as required. 2547 fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 2548 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 2549 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 2550 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2551 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2552 providing and fixing testing joint, made of 20 mm x 3 mm thick g.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chuck nuts and spring washers etc. complete as required. 2553 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. details of cost for one set 2554 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 2555 cost of type- 4 2556 structural repair & retrofitting 2557 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 2558 50 mm average thickness 2559 25 mm average thickness 2560 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 2561 bars upto 12 mm diameter 2562 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 2563 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 2564 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 2565 25mm thick in grade m 25 with cement content not less than 330 kg per cum 2566 50mm thick in grade m 25 with cement content not less than 330 kg per cum 2567 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 2568 repairs to roof 2569 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2570 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2571 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2572 repair to toilets 2573 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 2574 for thickness of tiles 10 mm to 25 mm 2575 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2576 repair to plaster and plinth protection 2577 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2578 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2579 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2580 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2581 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2582 with cement mortar 1:4 (1cement: 4 coarse sand) 2583 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2584 15mm cement plaster on rough side of single or half brick wall of mix 2585 1:6 (1 cement : 6 course sand) 2586 6mm cement plaster to ceiling of mix : 2587 1:3 ( 1 cement : 3 fine sand) 2588 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2589 two coats 2590 distempering with 1st quality acrylic distemper (ready made) having voc content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 2591 one or more coats on old work 2592 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2593 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2594 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2595 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2596 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2597 repairs to door / windows 2598 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2599 of area 3 sq. metres and below 2600 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2601 of area 3 sq. metres and below 2602 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2603 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2604 renewal of old putty of glass panes (length) 2605 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2606 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2607 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2608 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete fixed to steel windows by welding 2609 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2610 300 mm weighing not less than 200gms. 2611 250 mm weighing not less than 150gms. 2612 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 2613 100x58x1.90 mm 2614 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2615 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2616 300 x 10mm 2617 150 x 10mm 2618 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2619 125 mm 2620 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 2621 twin rubber stopper 2622 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 2623 providing and fixing to existing door frames. 2624 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 2625 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2626 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2627 with isi marked stainless steel butt hinges of required size 2628 kiln seasoned and chemically treated hollock wood 2629 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2630 with 12 mm mild steel u beading 2631 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2632 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2633 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2634 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2635 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2636 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2637 4.0 mm thick glass panes 2638 applying priming coat : 2639 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 2640 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2641 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2642 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2643 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2644 one or more coats on old work 2645 repairs to flooring 2646 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2647 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2648 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 2649 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 2650 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 2651 25 mm thick 2652 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 2653 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 2654 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 2655 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 2656 miscellaneous 2657 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2658 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2659 cement mortar 1:6 (1 cement : 6 coarse sand) 2660 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2661 cement mortar 1:4 (1 cement :4 coarse sand 2662 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2663 plumbing work of type-4 2664 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2665 75 to 80 mm dia pipe 2666 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2667 15 mm to 40 mm nominal bore 2668 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2669 up to 150 mm diameter 2670 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2671 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2672 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2673 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 2674 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2675 up to 150 mm diameter 2676 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2677 rectangular manhole 90x80 cm and 45 cm deep 2678 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2679 110 mm diameter 2680 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2681 a) coupler 2682 110 mm 2683 b) bend 87.5° 2684 110 mm bend 2685 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 2686 75 mm diameter pipes 2687 100 mm diameter pipes 2688 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2689 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2690 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : 2691 w.c. pan with isi marked white solid plastic seat and lid 2692 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2693 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2694 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2695 kitchen sink without drain board 2696 610x510 mm bowl depth 200 mm 2697 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2698 a) 32mm dia (for wash basin) 2699 b) 40mm dia (for sink and urinal) 2700 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2701 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2702 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2703 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2704 providing & fixing c.p. brass waste coupling for pvc waste pipe. 2705 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2706 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2707 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2708 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2709 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2710 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2711 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2712 p-trap type floor trap 110 x 75 mm 2713 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2714 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2715 providing and fixing 100 mm sand cast iron grating for gully trap. 2716 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2717 providing & fixing soil, waste and vent pipes. 2718 a) 100mm dia centrifugally cast iron s & s pipe. 2719 b)75mm dia centrifugally cast iron s & s pipe. 2720 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 2721 a) for 100mm dia pipe. 2722 b) for 75mm dia pipe. 2723 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 2724 a) 100mm 2725 sand cast iron s&s as per is - 3989 2726 b) 75mm 2727 sand cast iron s&s as per is- 3989 2728 providing and fixing plaincast iron s & s sanitary bend. 2729 a) 100mm 2730 sand cast iron s&s as per is - 1729 2731 b) 75mm 2732 sand cast iron s&s as per is - 3989 2733 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 2734 a) 100x100x100mm 2735 b) 75x75x75mm 2736 providing and fixingcast iron terminal guard. 2737 a) 100mm 2738 b) 75mm 2739 providing & fixingcast iron coller. 2740 a)100 mm 2741 sand cast iron s&s as per is - 3989 2742 b)75mm dia. 2743 sand cast iron s&s as per is - 3989 2744 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 2745 a) 100mm 2746 b) 75mm 2747 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 2748 a) 100mm inlet & 75mm outlet. 2749 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2750 15 mm nominal outer dia pipes 2751 20 mm nominal outer dia pipes 2752 25 mm nominal outer dia pipes 2753 32 mm nominal outer dia pipes 2754 providing and fixing brass stop cock of approved quality. 2755 15 mm nominal bore 2756 providing and fixing gun metal gate valve with wheel of approved quality. 2757 a) 25mm dia nominal bore 2758 b) 32mm dia nominal bore 2759 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2760 a) 25mm. nominal bore 2761 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2762 a) 15mm nominal bore 2763 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2764 a) 15mm nominal bore 2765 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2766 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2767 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2768 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2769 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2770 a) 15mm nominal bore 2771 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2772 a) 15mm nominal bore 2773 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2774 a) 15mm nominal bore 2775 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2776 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2777 25mm nominal bore, weighing not less than 62 gms 2778 cutting holes up to 30x30 cm in walls including making good the same: 2779 with common burnt clay f.p.s. (non modular) bricks 2780 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2781 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2782 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2783 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2784 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2785 electrical work of type-4 2786 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2787 group b 2788 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2789 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2790 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2791 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2792 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2793 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2794 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2795 group b 2796 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2797 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2798 2 x 1.5 sq. mm 2799 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2800 25 mm 2801 32 mm 2802 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2803 100 mm x 100 mm x 60 mm deep 2804 150 mm x 75 mm x 60 mm deep 2805 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2806 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2807 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2808 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2809 supplying and fixing brass batten/ angle holder including connection etc. as required. 2810 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2811 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2812 6 way, double door 2813 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2814 4 way (4 + 12), double door 2815 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2816 single pole 2817 single pole and neutral 2818 triple pole 2819 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2820 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2821 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2822 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2823 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2824 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2825 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2826 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2827 upto 450 mm sweep 2828 supply of 15w surface mounted round led with all accessories as per standard item.. 2829 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2830 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2831 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2832 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2833 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2834 300 mm sweep 1300 rpm 2835 cost of workshop 2836 repairs to roof 2837 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 2838 asbestos cement sheet 2839 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 2840 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 2841 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 2842 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 2843 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 2844 repair to plaster and plinth protection 2845 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2846 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2847 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2848 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2849 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2850 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2851 with cement mortar 1:4 (1cement: 4 coarse sand) 2852 12mm cement plaster of mix : 2853 1:6 (1 cement : 6 course sand) 2854 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2855 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2856 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2857 old work (one or more coats) 2858 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2859 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2860 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2861 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2862 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2863 miscellaneous 2864 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 2865 in cement mortar 2866 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2867 cement mortar 1:6 (1 cement : 6 coarse sand) 2868 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2869 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2870 75 to 80 mm dia pipe 2871 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2872 110 mm diameter 2873 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2874 a) coupler 2875 110 mm 2876 b) bend 87.5° 2877 110 mm bend 2878 electrical cost of workshop 2879 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2880 group c 2881 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2882 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2883 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2884 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2885 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2886 2 x 1.5 sq. mm 2887 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2888 25 mm 2889 32 mm 2890 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2891 100 mm x 100 mm x 60 mm deep 2892 150 mm x 75 mm x 60 mm deep 2893 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2894 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2895 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2896 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2897 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2898 6 way, double door 2899 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2900 4 way (4 + 12), double door 2901 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2902 single pole 2903 single pole and neutral 2904 triple pole 2905 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2906 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2907 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2908 upto 450 mm sweep 2909 supply of 15w surface mounted round led with all accessories as per standard item.. 2910 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2911 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2912 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2913 supply of 30w led recess mounted fixturemake-philips cat no.rc380b led30s-6500 l60w60 psd od s1 or equivalent. 2914 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2915 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2916 450 mm sweep 1400 rpm 2917 electric sub station 2918 repairs to roof 2919 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2920 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2921 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2922 repair to plaster and plinth protection 2923 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2924 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2925 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2926 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2927 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2928 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2929 with cement mortar 1:4 (1cement: 4 coarse sand) 2930 12mm cement plaster on rough side of single or half brick wall of mix 2931 1:6 (1 cement : 6 course sand) 2932 6mm cement plaster to ceiling of mix : 2933 1:3 ( 1 cement : 3 fine sand) 2934 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2935 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2936 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2937 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2938 one or more coats on old work 2939 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2940 two coats 2941 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2942 old work (one or more coats) 2943 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2944 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2945 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2946 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2947 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2948 repairs to door / windows 2949 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2950 of area 3 sq. metres and below 2951 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2952 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2953 renewal of old putty of glass panes (length) 2954 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer. 2955 using flats 30x6mm for diagonal braces and central cross piece 2956 miscellaneous 2957 providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia m.s. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with m.s. tubes, m.s. tube challies, m.s. clamps and m.s. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .the scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of engineerin-charge .the elevational area of the scaffolding shall be measured for payment purpose .the payment will be made once irrespective of duration of scaffolding. note: - this item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 2958 anti-termite treatment 2959 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2960 110 mm diameter 2961 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2962 a) coupler 2963 110 mm 2964 b) bend 87.5° 2965 110 mm bend 2966 pump room. 2967 repairs to roof 2968 repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (dr. fixit make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge.with cement mortar 1:4 (1cement: 4 coarse sand) 2969 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2970 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2971 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2972 repair to plaster and plinth protection 2973 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2974 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2975 with cement mortar 1:4 (1cement: 4 coarse sand) 2976 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2977 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2978 15mm cement plaster on rough side of single or half brick wall of mix 2979 1:6 (1 cement : 6 course sand) 2980 6mm cement plaster to ceiling of mix : 2981 1:3 ( 1 cement : 3 fine sand) 2982 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2983 one or more coats on old work 2984 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2985 two coats 2986 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2987 old work (one or more coats) 2988 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2989 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2990 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2991 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2992 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2993 repairs to door / windows 2994 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2995 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2996 renewal of old putty of glass panes (length) 2997 miscellaneous 2998 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 2999 in cement mortar 3000 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 3001 110 mm diameter 3002 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 3003 a) coupler 3004 110 mm 3005 b) bend 87.5° 3006 110 mm bend 3007 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 3008 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 3009 sewerage system 3010 excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 3011 all kinds of soil 3012 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 3013 pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 3014 providing and laying non-pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 3015 150 mm dia. r.c.c. pipe 3016 450 mm dia. r.c.c. pipe 3017 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40 mm nominal size) 3018 150 mm diameter s.w.pipe (l*.35*.10) 3019 450 mm diameter s.w.pipe (l*.6*.15 ) 3020 constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with rcc top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 3021 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 3022 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 3023 extra for depth for manholes: 3024 size 90 x 80 cm 3025 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 3026 constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with fps bricksclass designation 75in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 3027 0.91m deep with sfrc cover and frame (heavy duty hd-20 grade designation) 560mm internal diameter conforming to i.s:12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) 3028 with common burnt clay f.p.s.(non module) brick of class designation 7.5 3029 extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . 3030 with common burnt clay f.p.s.(non module) brick of class designation 7.5 3031 providing and fixing square mouths. w. gully trapclass sp-1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 3032 180 x 150 mm. size p type 3033 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 3034 providing m.s. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 3035 with 20x20 mm square bar 3036 cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 psi for sewer line from 150mm dia upto 300mm 3037 cleaning and desilting of gully trap chamber, including removal ofrubbish mixed with earth etc. and disposal of same, all as per thedirection of engineer-in-charge. 3038 cost of entrance gate 3039 earth work 3040 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.all kinds of soil 3041 extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.all kinds of soil 3042 concrete work 3043 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zoneiii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 3044 providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii): 4 graded stone aggregate 12.5mm nominal size) 3045 providing & applying a coat of residual petroleum bitumen of grade of vg-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 3046 reinforced cement concrete 3047 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 3048 upto plinth level 3049 (i) r.c.c. work in footing 3050 (ii) r.c.c. work in beam 3051 (iii) r.c.c. work in columns 3052 above plinth to floor-v lvl 3053 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 3054 (i) r.c.c. work in beam 3055 (ii) r.c.c. work in columns 3056 (iii) r.c.c. work in slab 3057 centering and shuttering including strutting, propping etc. and removal of form for all heights : 3058 foundations, footings, bases of columns, etc. for mass concrete. 3059 columns,pillars, piers, abutments, posts and struts. 3060 suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 3061 lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 3062 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500d or more. 3063 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. thermo-mechanically treated bars of grade fe-500 d or more. 3064 masonry work 3065 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : cement mortar 1:6 (1 cement : 6 coarse sand) 3066 wood and pvc work 3067 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including isi marked stainless steel butt hinges with necessary screws. 3068 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. fixed to steel windows by welding. 3069 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. twin rubber stopper 3070 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete(a) 125 mm. 3071 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 3072 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 3073 300 x 10mm 3074 200 x 10mm 3075 steel work 3076 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 3077 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 3078 steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 3079 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 3080 flooring 3081 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 3082 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 3083 finishing 3084 12 mm cement plaster on the fair side of single or half brick wall (a) 1:6 (1 cement: 6 coarse sand) 3085 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). 3086 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 3087 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 3088 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work (two or more coats) over and including water thinnable priming coat with cement primer. 3089 finishing walls with water proofing cement paint of required shade : new work (two or more coats applied @ 3.84 kg/10 sqm) 3090 applying priming coat: 3091 with ready mixed aluminium primer of approved brand andmanufacture on resinous wood and plywood 3092 with ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 3093 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 3094 finsihing with epoxy paint (two or more coats) at all locations pepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.on steel work. 3095 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 3096 water proofing 3097 painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 3098 supply & fixing of prepainted coloured trapezoidal or approved profiled sheeting 1000-1020 mm cover width, 28-30 mm high crests with subtle square fluting in the five pan at nominal 190-255 mm (as approved by eic) centre-to-centre manufactured out of 0.50 mm tct hi-tensile prepainted zincalume /galvalume steel (az-150 gsm. aluminium –zinc alloy metallic coating of total both sides 550 mpa yield stress as per as-1397). colour/ exterior coat of rmp 20 micron top coat applied over 5 micron primer and a 5 micron polyester back coat applied over 5 microns primer or equivalent coating/painting. the sheet shall have wide pans with stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlin support. the male end of the sheet shall have anti-capillary flute at side laps to prevent leakages. the sheet shall be fixed by means of anti corrosive approved make rust shield (epoxy polymer) coated self-drilling self tapping fasteners 12-14 x 55 mm with epdm seals through crest for roofing and 12-24 x 20 mm through valley (pans) for wall cladding. the sheet shall be supplied in lengths maximum up to 6-12 meter long to suit site dimensions. the scope includes all sealing of joint, curves, edges or other accessories with silicon sealant. 3099 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 3100 electricalworksmain gate 3101 sub head - i: circuit cum point wiring 3102 switch control light points 3103 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 3104 group c 3105 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required. (switch control secondary points) 3106 group c 3107 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. (switch control primary points) 3108 group c 3109 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutindependent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required. (switch control secondary points) 3110 group c 3111 mcb control light points 3112 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. (switch control primary points) 3113 primary point controlled by one mcb. 3114 same as item above but secondary point. i.e. points to be looped with primary pointwith 2.5 sqmm wire and point wiring 3115 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 3116 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 3117 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 3118 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 3119 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 3120 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 3121 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 3122 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 3123 supplying and fixingsuitable size gi box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 amp modular socket outlet and 5/6 a modular switch, connection etc. as required. 3124 supply and wiringfor 250 volts singlephase and neutral 2 nos 6 amps socket outlate with control by 1 no switched with 2.5 sq.mm pvcinsulatedcopper conductor1100 volts grade stranded flexible frls wires inconcealed or surface mounted 25 mm dia 2mm thickpvc conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick gi box with grid plate and earthingofthird pin of the socket with2.5sq. mm pvc insulated copper conductor strandedflexiblefrlswire.(maximum four no. of switches socket shall be connected on onecircuit) 3125 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 3126 supplying and fixing 63 a, 415 v, tpn industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 3127 supplying and fixing 80 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 3128 supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required. 3129 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 amps modular sp mcb, “c” curve including connection, painting etc. as required. (acs & gysers) 3130 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3131 telephone socket outlet 3132 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 3133 1 or 2 module (75mmx75mm) 3134 6 module (78mm x 205 mm x 50 mm) 3135 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 3136 3 pin , 5/6 amps socket outlet 3137 5/6 amps switch 3138 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 3139 25 mm 3140 32 mm 3141 subhead -ii - fittings & fixtures 3142 supply, installation, testing and commissioning of 10 w bulk head light. 3143 supply, installation, testing and commissioning of 5w mirror light. 3144 supply, installation, testing and commissioning of 18w surface/recessed mounted led circular downlighter. 3145 supply, installation, testing and commissioning of 18/20w wall/surface mouted 4 ft. led 3146 supply, installation, testing and commissioning of 15wsurface mountedled square downlighter. 3147 supply, installation, testing and commissioning of 12/9wrecessed mountedled circular downlighter. 3148 supply, installation, testing and commissioning of9w (nominal)wall bracket light 3149 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019),thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 3150 supplyinstallation, testing and commissioning of 250 mm dia domestic exhaust fan 3151 subhead - iii - distribution boards 3152 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 3153 6 way, double door 3154 8 way, double door 3155 12 way, double door 3156 supplying and fixing following way, three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (but without mcb/ rccb/ isolator) 3157 4 way (4 + 12), double door 3158 6 way (4 + 18), double door 3159 8 way (4 + 24), double door 3160 supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer) as required . (note :vertical type mcb tpdb is normally used where 3 phase outlets are required.) 3161 12 way (4 + 36), double door 3162 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 3163 single pole 3164 single pole neutral 3165 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 3166 40 a 3167 63 a 3168 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 3169 25 a 3170 40 a 3171 63 a 3172 supplying and fixing following rating, double pole, (single phaseand neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 3173 25 a 3174 40 a 3175 63 a 3176 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 3177 basket ball court 3178 for one no. of court 3179 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per directionof engineer - in - charge nominal concrete 1:3:6 or richer mix 3180 providing and laying c.c. pavement of mix m-25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer-incharge. (the panel shuttering work shall be paid for separately). (note:- cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 3181 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 3182 thermo-mechanically treated bars of grade fe-500d or more. 3183 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 3184 40 mm thick with 20 mm nominal size stone aggregate 3185 providing and fixing ac strips in joints ofcement concrete floors.70 mm wide and 4 mm thick. 3186 finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. 3187 on steel work: (on poles) 3188 vertical member (8in dia & 3.2 m long) 3189 horizontal member (8in dia & 2.5 m long) 3190 ugt with pump house 3191 cost of under ground sump 3192 cost of 2 set of 7.5 hp submersible pump (i.e. rs 75,000, each) including all control panel and fitting charges, etc. 3193 external electrical work 3194 subhead - i - main boards 3195 meter boards 3196 supply, installation, testing and commissioning of m.v. cubical type totally enclosed dust, dump and vermin proof meter bords complete with bus bars, mv danger notice plate, on surface isi marked electronic kwh meter, indication lamps, cts, interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingmcbs mccbs and kwh meters complete as required. 3197 panel- kitchen dining 3198 incomer 3199 1 no.40 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3200 metering & indication 3201 1 set of r,y,b phase indicating lamps 3202 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 40/5a cts (40a/500v) rating 3203 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3204 bus-bar 3205 1 set of 50a tpn aluminium bus bar with colour coded pvc sleeves 3206 out going: 3207 2 nos. 25a tpn mcb of 10ka 3208 3 no. 40a dp mcb of 10ka. 3209 supplying,receiving, fixing, testing & commissioning ofabove described panel 3210 meter boards - type-iii, type ii & type i 3211 incomer 3212 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3213 metering & indication 3214 1 set of r,y,b phase indicating lamps 3215 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3216 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3217 bus-bar 3218 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3219 out going: 3220 4 nos. 40a tpn mcb of 10ka 3221 2 nos. 40a dp mcb of 10ka. 3222 supplying,receiving, fixing, testing & commissioning ofabove described panel 3223 meter boards -dormitory boys & girls 3224 incomer 3225 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3226 metering & indication 3227 1 set of r,y,b phase indicating lamps 3228 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3229 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3230 bus-bar 3231 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3232 out going: 3233 4 nos. 40a tpn mcb of 10ka 3234 2 nos. 40a dp mcb of 10ka. 3235 supplying,receiving, fixing, testing & commissioning ofabove described panel 3236 meter boards - vice principle residence, guest house, workshop & gym 3237 1 no.40amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3238 panel -school building & mp hall 3239 incomer 3240 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3241 metering & indication 3242 1 set of r,y,b phase indicating lamps 3243 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3244 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3245 bus-bar 3246 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3247 out going: 3248 4 nos. 40a tpn mcb of 10ka 3249 3 no. 40a dp mcb of 10ka. 3250 supplying,receiving, fixing, testing & commissioning ofabove described panel 3251 subhead - ii - earthing 3252 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 3253 earthing with cu. earth plate 600mm x 600mm x 3mm thick includingaccesssories, and providingmasonary enclosurewith cover plate (ci heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required. 3254 supplying and laying 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode, including connection with g.i. nut, bolt, spring, washer excavation and refilling etc. as required. 3255 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 3256 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 3257 cost of septic tank [for repairing of existing septic tank]
  • View Tender
  • Document
  • Bid Support
13 Recreational Services
image image
Central Government And Public Sector
TRN :49065138 |  02 Jun, 2025
Tender Value : 8.00 Crore
 Bhopal - Madhya Pradesh
Tender for empanelment for lighting arrangement/event management work. - tube light2 one day3 two days4 three days5 more than three6 l.e.d. tube light7 one day8 two days9 three days10 more than three11 vapour lamp12 one day13 two days14 three days15 more than three16 par 38 watt17 one day18 two days19 three days20 more than three21 par 54 watt22 one day23 two days24 three days25 more than three26 par 64 watt27 one day28 two days29 three days30 more than three31 led - par 150 watt32 one day33 two days34 three days35 more than three36 led - par 160 watt37 one day38 two days39 three days40 more than three41 led bulb (with led bulb (with holder) 30 watt42 one day43 two days44 three days45 more than three46 led bulb (with holder) 60 watt47 one day48 two days49 three days50 more than three51 led bulb (with holder) 90 watt52 one day53 two days54 three days55 more than three56 led bulb (with holder) 120 watt57 one day58 two days59 three days60 more than three61 led bulb (with holder) 150 watt62 one day63 two days64 three days65 more than three66 bulb (with holder) 200/230 watt67 one day68 two days69 three days70 more than three71 bulb(with holder) 100/40/60 watt72 one day73 two days74 three days75 more than three76 bulb(with holder) 25/15 watt77 one day78 two days79 three days80 more than three81 nivar 6.2 small (of 150 bulbs)82 one day83 two days84 three days85 more than three86 nivar 6.2 big (of 300 bulbs)87 one day88 two days89 three days90 more than three91 rope light (per meter)92 one day93 two days94 three days95 more than three96 l.e.d. rope light (per meter)97 one day98 two days99 three days100 more than three101 led rise light (per piece)102 one day103 two days104 three days105 more than three106 led batten light (colour) - rgbw (per meter)107 one day108 two days109 three days110 more than three111 led batten light (ww) (per meter)112 one day113 two days114 three days115 more than three116 led strobe rgbw (150 to 200 watt)117 one day118 two days119 three days120 more than three121 led strobe (ww) (150 to 200 watt)122 one day123 two days124 three days125 more than three126 led (moving wash) (300 watt)127 one day128 two days129 three days130 more than three131 garland (coloured/white) - 6.2 watt132 one day133 two days134 three days135 more than three136 bulb rise light (per piece)137 one day138 two days139 three days140 more than three141 halogen light (per piece) 500 watt142 one day143 two days144 three days145 more than three146 halogen light (per piece) 1000 watt147 one day148 two days149 three days150 more than three151 metal light (per piece) white - 250 watt152 one day153 two days154 three days155 more than three156 metal light(per piece) white - 400 watt157 one day158 two days159 three days160 more than three161 metal light(per piece) white - 800 watt162 one day163 two days164 three days165 more than three166 colour metal light(per piece) 250 watt167 one day168 two days169 three days170 more than three171 colour metal light(per piece) 400 watt172 one day173 two days174 three days175 more than three176 colour metal light(per piece) 800 watt177 one day178 two days179 three days180 more than three181 led. flood light (per piece) 30 watt182 one day183 two days184 three days185 more than three186 led. flood light (per piece) 46 watt187 one day188 two days189 three days190 more than three191 led. flood light (per piece) 60 watt192 one day193 two days194 three days195 more than three196 led. flood light (per piece) 100 watt197 one day198 two days199 three days200 more than three201 l.e.d. flood light (per piece) 200 watt202 one day203 two days204 three days205 more than three206 mirror wall (15-24 inch round)207 one day208 two days209 three days210 more than three211 bubble machine (per piece)212 one day213 two days214 three days215 more than three216 ice machine (per piece)217 one day218 two days219 three days220 more than three221 spot light (per piece) 500 watt222 one day223 two days224 three days225 more than three226 spot light (per piece) 1000 watt227 one day228 two days229 three days230 more than three231 pin spot (12 watt)232 one day233 two days234 three days235 more than three236 follow spot (per piece) 10 r237 one day238 two days239 three days240 more than three241 follow spot (per piece) 15 r242 one day243 two days244 three days245 more than three246 follow spot (per piece) 1200 r247 one day248 two days249 three days250 more than three251 follow spot (per piece) 2500 r252 one day253 two days254 three days255 more than three256 sharpie light (300 watt) (per piece)257 one day258 two days259 three days260 more than three261 l.e.d. moving head (per piece)262 one day263 two days264 three days265 more than three266 colorvas (100 watt) (per piece)267 one day268 two days269 three days270 more than three271 pointy (300 watt) (per piece)272 one day273 two days274 three days275 more than three276 blender 650 watt (per piece)277 one day278 two days279 three days280 more than three281 rotor chandelier wall - effect light (150 watt) (per piece)282one day283 two days284 three days285 more than three286 cold pyro (ingredient)287 one day288 two days289 three days290 more than three291 colour c.t. (for 30x60 size) (per piece)292 one day293 two days294 three days295 more than three296 haze machine (1500 watt) (per piece)297 one day298 two days299 three days300 more than three301 smoke machine (1500 watt) (per piece)302 one day303 two days304 three days305 more than three306 water effect (1000 watt) (per piece)307 one day308 two days309 three days310 more than three311 fire effect (1500 watt) (per piece)312 one day313 two days314 three days315 more than three316 frisnel (500 watt - 1000 watt) (per piece)317 one day318 two days319 three days320 more than three321 flicker (20 watt) (per piece)322 one day323 two days324 three days325 more than three326 u.v. light (20 watt - 40 watt) (per piece)327 one day328 two days329 three days330 more than three331 profile light (1000 watt) (per piece)332 one day333 two days334 three days335 more than three336 sky light (4000 watt)337 one day338 two days339 three days340 more than three341 photo spot (40 watt - 60 watt) (per piece)342 one day343 two days344 three days345 more than three346 dimmer light (4 kw) (per piece)347 one day348 two days349 three days350 more than three351 d.m.x. control panel352 one day353 two days354 three days355 more than three356 control panelevo light console357 one day358 two days359 three days360 more than three361 control panelarena light console362 one day363 two days364 three days365 more than three366 control panelm.a. 2/3 light console367 one day368 two days369 three days370 more than three371 spitter (6 - 8 channel)372 one day373 two days374 three days375 more than three376 light stand - 10 ft/15 ft377 one day378 two days379 three days380 more than three381 switch board (single phase) 5amp/15amp382 one day383 two days384 three days385 more than three386 switch board (three phase) 5amp/15amp387 one day388 two days389 three days390 more than three391 l. l.e.d. tv display/board (per sq. ft.) 42 inch392 one day393 two days394 three days395 more than three396 l.e.d. tv display/board (per sq. ft.) 55 inch397 one day398 two days399 three days400 more than three401 l.e.d. tv display/board (per sq. ft.) 65 inch402 one day403 two days404 three days405 more than three406 l.e.d. tv display/board (per sq. ft.) e.d. display system (per sq. ft.)407 one day408 two days409 three days410 more than three411 sky fold (per running feet)412 one day413 two days414 three days415 more than three416 generator 10 kva417 one day418 two days419 three days420 more than three421 generator 15 kva422 one day423 two days424 three days425 more than three426 generator 40 kva427 one day428 two days429 three days430 more than three431 generator 63 kva432 one day433 two days434 three days435 more than three436 generator 125 kva437 one day438 two days439 three days440 more than three441 generator 250 kva442 one day443 two days444 three days445 more than three446 generator 500 kva447 one day448 two days449 three days450 more than three451 service line (per meter)452 one day453 two days454 three days455 more than three456 main switch (100-200 ampere)457 one day458 two days459 three days460 more than three461 change over 100 ampere462 one day463 two days464 three days465 more than three466 change over 200 ampere467 one day468 two days469 three days470 more than three471 truss aluminium (running feet)472 one day473 two days474 three days475 more than three476 truss m.s. (running feet)477 one day478 two days479 three days480 more than three days
  • View Tender
  • Document
  • Bid Support
14 Defence
image image
Statutory Bodies and Commissions/Committees
TRN :49019704 |  12 May, 2025
Tender Value : 0
 Karu - Ladakh
Tender for tender for supply and construction of ug tac hq (qty-03 nos) under job no 6151/2025-26 (s&c) (cow); 1 ug tac hq nos 1 2 soakage/septic tank cover nos 6 3 iron foot scraper nos 2 4 lightening conductor nos 1 5 earthing building nos 1 6 fire extinguisher 1 kg ball type nos 8 7 fire extinguisher 2 kg nos 8 8 smoke alarm nos 10 9 35 kva dg set nos 1 10 water storage tk 500 ltr sintex nos 4 11 elect items set 1 annx i 12 ppr items set 1 annx ii 13 sanitary items set 1 annx iii 1 supply and fix led tube light fitting1x 20 watt, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size(more than 05 yrs warranty). nos 6 2 supply and fix led invertor rechargeable tube light fitting1x 20 watt , complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.(more than 05 yrs warranty). nos 5 3 supply and fix led luminaire 600mm x 600mm of 30 watt ,220 volt ac surface type with high efficiency soft glare light complete with driver holder & led lamp suitable for roof surface / ceiling incl including connecting up with twin core twisted flexible copper conductor cable with suitable size complete.(more than 05 yrs warranty). nos 8 4 supply and fix led mirror light fitting1 x 10 watt , complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size(more than 05 yrs warranty). nos 5 5 supply and fix bulk head 1x10w, 230 volt incl led light driver holder connecting up with twin core twisted flexible copper conductor cable with suitable size complete. (more than 05 yrs warranty). nos 3 6 supply and fix pvc lamp holder with isi mark. nos 5 7 supply and fix led invertor type rechargeable bulb 10 watt with isi mark.(more than 05 yrs warranty). nos 5 8 supply and fix switch socket combination 5 pin, 15 amp with isi mark. nos 8 9 supply and fix switch socket combination 5 pin, 5 amp with isi mark. nos 14 10 supply and fix ceiling rose three terminals (five layered) pvc poly carbonate, isolated body. nos 32 11 m&l for point wiring complete for one light point/ exhaust fan point/ bell point controlled by one switch with using 1.5 sqmm 1100 volt including 1.5 sqmm frls pvc insulated, unsheathed, multi standard copper conductor cable as continues earth wire connected to metallic bodies of luminaries/ fan etc at one end and to common earth dolly at other end, complete wiring drawn through pvc concealed of suitable size (as per conductor run) medium grade, isi mark including all accessories and fitting / junction box/ inspection covers/flexible conduit/ metal flush box of suitable size for fixing any types of switches/ socket etc point 37 12 all as above item no 11 here in before but point wiring for one socket point 6 amps on indepent board complete all as specified. point 10 13 all as above item no 11 here in before but point wiring for one socket point 6 amps on same board complete all as specified. point 4 14 all as per ser items no 11 here in before but with 2.5 sqmm frls copper wire with 1.5 sqmm frls copper earth wire for independent 15 amp points. point 8 15 sub main wiring 2x4 sqmm frls pvc insulated, unsheathed, multi standard copper conductor single core with earth wire complete. rm 40 16 supply and fix double door mcb distribution box spn 8 way complete conforming to ip65. nos 2 17 supply and fix mcb spn 32 amp,230v 50hz 10ka, b series. nos 2 18 supply and fix mcb sp 16 amp 240v 50hz b series. nos 2 19 supply and fix mcb sp 20 amp 240v 50hz b series. nos 3 20 supply and fix mcb sp 32 amp 240v 50hz b series. nos 4 21 supply and fix mcb sp 3 amp 240v 50hz b series. nos 3 22 supply and fix pvc body exhaust fan 200 mm sweep with louvers shutter, 230 volt ,50 hz, rpm 1200, copper winding and suitable size of hole for fixing of fan complete. nos 5 23 supply and fix switch piano type 5 amps isi marked. nos 37 1 pp-r pipe (pn 20/sdr-6) 3 layer with outer dia40mm with isi mark. rm 30 2 pp-r pipe (pn 20/sdr-6) 3 layer with outer dia 32mm rm 50 3 pp-r tank connector outer dia 32mm. nos 2 4 pp-r gate valve connector outer dia 40mm nos 2 5 pp-r elbow 90 degree plane outer dia 40mm nos 12 6 pp-r elbow 45degree plane outer dia 40mm nos 12 7 pp-r elbow 90 degree plane outer dia 32mm nos 12 8 pp-r elbow 45 degree plane outer dia 32mm nos 12 9 pp-r tee reducer 40-32mm nos 12 10 pp-r union outer dia 32mm nos 5 11 pp-r wall clamp dia 40mm nos 16 12 pp-r wall clamp dia 32mm nos 25 13 pp-r socket outer dia 32mm nos 10 14 pp-r socket outer dia 40mm nos 8 15 pp-r plug dia 25mm nos 5 16 pp-r plug dia 15mm nos 5 17 pp-r socket, elbow & tee each of dia 25mm set 25 18 pp-r socket, elbow & tee each of dia 20mm set 25 19 nitrile insulation min 50mm thick for pp-r pipe rm 80 20 adhesive solution sr-998 for jointing of insulation .make fevicol ltrs 5 21 1mm thick and 1 mtr wide aluminium sheet to cover nitrile insulation. minimum 50mm should be overlap and fixed with suitable length self taping screw distance of screw not more than 150mm c/c and ss band 13mm wide x 0.40mm thick with ms ring should be provided wherever required at suitable interval. rm 30 22 pp-r tee outer dia 32mm nos 5 23 pp-r female threaded elbow outer dia 32mm x 15 mm nos 25 24 pp-r male threaded elbow outer dia 32mm x 15 mm nos 5 25 pp-r female threaded socket outer dia 32mm x 15mm nos 10 26 pp-r female threaded socket dia 25mm nos 10 27 pp-r wall clamp dia 75mm nos 10 1 vitreous china ceramic ewc p &s (white colour) with 10 ltrs capacity pvc flushing cistern with seat cover (pvc) complete with entire accessories as per good engineering practice. nos 5 2 corner shelf of toughned glass with chromium plated steel frame. nos 5 3 cp towel rail 600mm long 20mm dia. nos 5 4 ceramic wash basin (630 x 450mm) (white colour) accessories to include waste pipe, coupling etc. nos 5 5 urinal pot vetreous china bowl urinal pot flat back model 5004 confirming to is 771 (part 3) sec 2 nos 5 6 chromium plated (cp) brass pillar cock. nos 5 7 chromium plated (cp) soap dish isi mark. nos 5 8 chromium plated (cp) bib cock mixture (long body). nos 5 9 chromium plated (cp) brass bib cock (short body) with isi mark. nos 5 10 chromium plated (cp) brass bib cock (long body) isi mark nos 5 11 chromium plated (cp) brass stop cock. nos 15 12 pvc insulated connection 16mm dia 450mm long nos 15 13 decorative looking mirror bath cabinet (600mm x 450mm) with suitable pvc frame nos 5 14 wash hand basin shelf of ss with chromium plated (cp) steel frame. nos 5 15 chromium plated (cp) steel coat hook with two prongs. nos 10 16 dcwpe pipe 75mm dia rm 35 (i) socket nos 10 (ii) tee nos 10 (iii) elbow nos 10 17 dcwpe 110mm dia rm 30 (i) socket nos 10 (ii) tee nos 5 (iii) elbow nos 5 18 stainless steel jali with hole for waste pipe. nos 10 19 stainless steel jali without hole. nos 5 20 pvc nahani trap 75mm dia. nos 10 21 pvc vent pipe 2 mtr length ,75mm dia with cowl 75mm dia. nos 2 22 health foucet with 1.2 mtr long nos 5
  • View Tender
  • Document
  • Bid Support
15 Construction
image image
State Government
TRN :49022392 |  13 May, 2025
Tender Value : 31.44 Lacs
 Gangapur - Maharashtra
Tender for providing electrical installation in, premises street light, water pump and fire extinguisher for the newly constructed zilla parishad primary health center (p .h .c)main building (g.f+f.f) [under scheme d.p.c. (general) year 2022-23, 34512595 construction expantion & m/ce & repairs of p.h.c/ phsc) at village,lasur stationtq. gangapurdist. chhatrapati sambhajinagar.= 1 supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit 2 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 3 supplying anderectingpvctrunking (pvc casing-n-capping)ofsize20 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 4 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 5 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize40 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 6 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 7 supplying and erecting green earth wire 1x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 8 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 9 supplying and erecting green earth wire 1x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 10 supplying and erecting mains with 4x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 11 supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 12 supplying and erecting mains with 4x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 13 supplying and erecting green earth wire 1x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 14 supplying and erecting mains with 4x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 15 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 16 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 17 supplying and erectingceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. 18 supplying and erectingmodular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 19 supplying and erectingmodular type switch 16aduly erected on provided plate and box with wiring connections complete. 20 supplying and erectingmodular type bell-push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. 21 supplying and erectingmodular type 3 pin 6amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. 22 supplying and erectingmodular type 3 pin 6 / 16amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 23 supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. 25 supplying and erecting pvc surface modular switch box with double mounting plate for 2module duly erected. 26 supplying and erecting pvc surface modular switch box with double mounting plate for 3module duly erected. 27 supplying and erecting pvc surface modular switch box with double mounting plate for 6module duly erected. 28 supplying and erecting pvc surface modular switch box with double mounting plate for 12module duly erected. 29 supplying and erecting 16 / 20 / 25 a starter (modular range) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 30 point wiring for light/bell/exhaust fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 31 point wiring for ceiling fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 32 wiring for plug on board withswitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no: wg-pw/cw 33 supplying and erectingled square / circular max. 11 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 34 supplying and erectingled square / circular max. 14 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 35 supplying and erectingled square / circular max. 18 w down lighter/ panel light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 36 supplying and erectingledpanel light(600mm x 600mm) max. 30 whaving crca powder coated housing,polystyrene diffuser havingsystem lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 37 supplying and erecting anodized aluminium corridor / passage / mirror light led fitting (2 feet) max. 12wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%,thd<10%,p.f. >0.95, operating range of200-270v, surge protection of 2 kv, life class of 50,000 hrs. at l70b50, including driver with end caps on provided pvc block / wooden board with 3 years warranty. 38 supplying & erecting inverter led batten 10w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 39 supplying & erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 40 supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. 41 supplying and erecting integrated led street light fitting26 to 30w ip65 & ik08 class having single piece pressure die-cast aluminium housing ,having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 42 supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg-odf/fls2. 43 supplying and erecting integratedled street light fitting 100-110w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 44 supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg-odf/ptl 45 supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg-bkt/wb 46 supplying & erecting 3w, 230v integral type led lamp suitable for b-22 / e-27 base.(night lamp) 47 supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg-fn/cf 48 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. 49 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. 50 supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg-fn/exf 51 supplying and erectingenergy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg-fn/cf 52 supplying and erecting fan hook of 10 mm. m.s. round bar grouted in rcc slab with making the site as original. 53 providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 54 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no fg-fas/msc 55 supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof abs plastic body, high grade ss inner tank & 3kw heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermalcut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250v, 50hz, a.c. supply with inlet and outlet, with 3 core pvc flexible copper wire leads duly tested and marking sr. no. and date of erection complete. 56 supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). 57 supplying & erecting 15mm brass non return valve for inlet pipe of storage water heater. 58 providing fiber reinforced pvc flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete. 59 supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 60 supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 61 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigerant having 22swg thickness and inner dia/size 12mm complete. 62 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigeranthaving 22swg thickness and inner dia/size 16mm complete. 63 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. ap-wcr/wc 64 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. ap-wcr/wc 65 supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) 66 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine waveinverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology completeas per specification no.ap-inv 67 supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 68 supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270v and output voltage 200-250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. 69 supplying and erecting switch disconnector fuse (sdf) switch 415v, 100a,open execution, four poleac23 a rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to is/iec 60947-3 part-1/3hrc - din type fuse, insulation voltage 1000 vfor enclosing in panel with rotary handle for on / off operation (without hrc fuse) 70 supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a,powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / cc foundation. 71 supplying, erecting & marking spmcb 0.5a to 5a, c-series with rated short - circuit breaking capacity (icn) 10kain provided distribution board as per specification no. sw-swr/mcb 72 supplying, erecting & marking spmcb 6a to 32a, c-serieswith rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 73 supplying, erecting & marking spmcb 6a to 32a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 74 supplying, erecting & marking dpmcb 6 a to 32 a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 75 supplying, erecting & marking tpmcb 6a to 32a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 76 supplying, erecting & marking tpmcb 40a to 63a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 77 supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40awith required wiring connections and lugs etc. in provided distribution board. 78 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board. 79 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63ain provided distribution board. 80 supplying&erectingtriplepole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flushmounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb 81 supplyingand erecting single pole and neutral distributionboard (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw-swr/mcbdb 82 supplying & erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb /tp mcb/fp mcb/rccb/rcbo complete erected on angle iron/gi frame. 83 supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb1 84 providing & erecting 4 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb (rate of 3 pole mccb +20% for 4 pole mccb= 5309x20%+5309=6370.80) 85 supplying and erecting cupboard for enclosing switchgears orforany other purposemadefromselected marine plywood planks 19 mm thick duly varnished/ painted from inside and from outside with brass hinges and locking arrangement with suitable lock with keys in duplicate. cupboard shall be duly grouted with suitable size of iron work in wall at the bottom. (size of cupboard 0.5x1x2+0.5x1x2+1x1x2= 4 sq.mtrs.) 86 supplyinganderectingiron, sheet metal work consisting of crcasheets, varioussectionsofiron,plates, chequeredplates,rods,bars,mspipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 50x50x4mm angle @ 3.4 kgs x 6 mtrs.= 20.40 kgs i,e 20 kgs. 87 supplying and erecting 525 v 3 phase, 50 hz., mpp type capacitor having minimum overcurrent capacity of 1.8 in,peak inrush current capacity 300 inand minimum life 150000 hourskvarbank of all polypropylenecondensers (app)withthestandard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kvarunitsofp.f. correctionforoperationon 3 phase 50 hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and providedwithterminalcoverbox completeerected onprovidediron bracketoronfloordulytestedby licensee.( original p.f=0.8 desired p.f = 0.95 for this multiplying factor is 0.421. so 0.421 x 46.440 = 19.55 i.e 10 kvar x 2= 20 kvar) 88 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 89 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al (double run) 90 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 91 supplying & erecting g.i. pipe‘a’ class 50 mmdia.erectedfor enclosingxlpearmouredcable on wall/poleas per specification no. cb-ce 92 supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 93 supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mmoutside dia. double wall corrugatedpipes (dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 94 supplying & erectingcast iron cable indicatorplate buried along with route of cable for pvc / xlpe armoured cableas per specification no. cb-cip 95 supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thickcomplete on pole/wallas per specification no. cb-sb 96 providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh-pl/opl 97 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 98 providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 99 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. ea-ep 100 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. ea-ep 101 providingpipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea-ep 102 supplying and erecting gi strip of required size used for earthing on wall and/or any other purpose with necessary gi clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsas per specification no. ea-ep.(25x3mm strip. perpole 1.5 mtrs. so for 13 poles 13nos.x1.5mtrs.= 19.5 mtrs. weight of strip @0.590kgs/mtr. so 19.50mtrs.x0.590kgs.=11.51 kgs.) 103 supplying and erecting minimum three & above star rated 1 phase, 230 v, 50 hz, submersible pump set of 1.5 kw/2hp suitable for erection on open well, pump having delivery head from 29to 7 m and discharge from 30 to 600 litres. . per minute& pipe of suction 50 mm/delivery 50 mm diameter erected with necessary h type clamps as per specification no. wp-osp 104 supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. 105 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c. submersible/centrifugal pump set up to 3 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 106 supplying & erecting carbon dioxide (co2) fire extinguisher of 4.5 kg. capacity cartridge type conform to is 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. m. s. flat with nut & bolts routed in wall complete. 107 making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (02x02x02 foundation for main control panel stand and for street light control panel 0.2x0.2x0.2mtr.=0.16 cu.mtrs.) 108 makingm- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). 109 supplying and erecting isi mark gi pipe 50 mm dia.‘b’ class at position with accessories complete as per specification no. cw-plb/gp. 110 supplying and erecting high density polythene pipe isi mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete. 111 supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. 112 supplying and erecting non return valve 50 mm dia in position made of gun metal complete. 113 lum sump provision towards service connection charges1 no.3 phase @ rs. 55000/-/per total rs.55,000/-
  • View Tender
  • Document
  • Bid Support
16 Sugar
image image
Co-operative
TRN :49023911 |  20 May, 2025
Tender Value : 0
 Powayan - Uttar Pradesh
Tender for supply of general electrical items for season 2025-26 , description , remote bell , tong tester meco make 1000 amp a.c./d.c. , manual control fan regulater 4 steps, single module , mcb din rail channel, 35mm width , air heater heating element 1 meter single , amp.meter 4x4 ,0 - 600 amp ctr 600/5 , amp.meter 4x4 ,0 - 800 amp ctr 800/5 , amp.meter 4x4 ,0 - 1000 amp ctr 1000/5 , amp.meter 96x96mm , ctr 100/5 , amp.meter 4x4 ,0 - 50 amp ctr 50/5 , amp.meter 4x4 ,direct 0-10 amp & 0-20 amp , amp.meter 96x96mm, 150/5 , amp.meter 4x4 , 300/5 , amp.meter 4x4 , 400/5 , ct 50/5,60/5,100/5,150/5,300/5,400/5,600/5,500/5 , ct ae make 1000/5 , piller assambly for 800 amp , ct630/800 amp for acb , operating handle on/off 800 amp , dn 1 release , cable tie 4 , cable tie 6 , soldring paste , change over switch 400 amp in ss hpl /sucomake , indicator led 220 volt red , volt.meter 4 0 - 500 volt , contactor 6 way 30 amp. l&t/schneider/switch gean , amp. meter 0 - 15 amp 4 , amp. meter 0 -160 amp 4150/5 a/e / rc , power contactor 3ta22 230 volt , mcb single pole 32 ampschneider /l&t / abb , mcb double pole 16 amp schneider /l&t / abb , mcb double pole 20 amp schneider /l&t / abb , mcb dboule pole 32 amp schneider /l&t / abb , mcb triple pole 16 amp schneider /l&t / abb , mcb triple pole 20 amp schneider /havells , mcb triple pole 32 amp schneider /havells , mcb triple pole 63 amp schneider /havells , distribution board 12 way spn (mcb box) schneider /havells , digital energy meter 3 phase 4 wirectr 200/5 l&t , transfarmer 1 kva 230 volt , sambersibleflexible flat copper cable (35mm x3 core) , change over switch 800 amp 4 pole hewlls make l&t , change over switch 400 amp 4 pole hewlls make l&t , pvc copper cable660/1100 volt for unloder 1.5mm 16 core , carbon bush 50x32x32 usha/bosch , volt meter 4 0-100 volt a/e , oil resistance box 250 hp rb450 ra 146 oil immersed , dinodrive electronic controllereddy current control , pvc copper flat sambersible cable 6mm 3 core , electronic blower wolf make /eastman , spray gun h.duty , digital rpm meter 0-500 rpm wantran , fuse base nsh 20 amp , indicating lamp 240 volt complete hack/jigo , push button element 1 no , push button element 1 nc , mcb box 4 pole l&t , indicating lampr y b , piston drill machine complete wolf make bosh , hand lamp , push button element 1 no+1nc teknic , ct 30/5 , pvc coolling fan 5 hp 1440 rpm ke make simenss , pvc coolling fan 7.5 hp 1440 rpm ke make simenss , pvc coolling fan 10 hp 1440 rpm ke make simenss , motor fan cover ke make 5 hp 1440 rpm ke/ simenss , motor fan cover ke make7. 5 hp 1440 rpmke/simenss , motor fan cover ke make 10 hp 1440 rpm ke/simenss , allu. imhibiting crosen cable compound ke/simenss , hydraulic cable crimpingmachine upto 400 mm complte taparia , hydrauliccable crimping machine upto 95 mm compltetaparia , p t bulb 24 volt , slipring 90 hp 67 kwframe size lcw 250 , slipring250 hpframe size rw 10539 , slipring250 hp1480 rpm , carbon brush holder90hp lcw 250 , carbon brush holder150 kw rw 10539 , carbon brush holder370kw , spare for oil immersed star delta starter , a- moving arching contact with guttka , b- fix finger contact big , c- fix finger contact small , amp meter 72x72mm 30/5 , amp meter 72x72mm 100/5 , cannector element 35mm , connector element 50mm jigo/rc , connectorelement 70mm , electronic timer 415 volt 36-120 secd. simenss /l&t , g.i.g.o.l. varnised crodium nut & bolt with washers , ………………………………do…………………………….12x50mm , ………………………………do…………………………….10x50mm , ………………………………do…………………………….8x50mm , ………………………………do…………………………….6x50mm , ………………………………do…………………………….12x65mm , ………………………………do…………………………….10x65mm , ………………………………do…………………………….8x65mm , ………………………………do…………………………….6x65mm , ………………………………do…………………………….12x75mm , ………………………………do…………………………….10x75mm , ………………………………do…………………………….8x75mm , ………………………………do…………………………….6x75mm , drill machineh.duty bosch , v.s.f. treding tape 1/4 , v.s.f. treding tape 1/16 , v.s.f. treding tape 3/8 , v.s.f. treding tape 1/2 , v.s.f. treding tape 5/8 , v.s.f. treding tape 3/4 , control transfarmer input 415 volt a.c. output 230 volt d,.c. 0.5 kva wnton,gromption , geyser 25 ltr gromption/havells , change over switch 250 amp ss havells/l&t , cooling fan 75 hp bharat bijli/simenss , cooling fan 60 hp bharat bijli/simenss , cooling fan 40 hp bharat bijli/simenss , cooling fan 15 hp bharat bijli/simenss , cooling fan cover 75 hp ke make simenss/bharat bijli/kirloskar , cooling fan cover 60 hp ke make simenss/bharat bijli/kirloskar , cooling fan cover 10hp ke make simenss/bharat bijli/kirloskar , terminal plate 75 hp ke makesimenss/bharat bijli/kirloskar , terminal plate 7.5 hp ke make simenss/bharat bijli/kirloskar , terminal box 15 hp 160 kh simenss/bharat bijli/kirloskar , terminal box 7.5 hp kh 132simenss/bharat bijli/kirloskar , carbon brush 16x32x38 jyoti/bosch , carbon bush 10x22x38 , carbon brush 20x40x50 , carbon holder jyoti make jyoti , copper rod 1.5x18,long , g.i.g.o.l. varnised crodium nut & bolt with washer---- , …………………………..do………………………….16x50 , …………………………..do………………………….16x75 , …………………………..do………………………….18x50 , …………………………..do………………………….18x75 , …………………………..do………………………….15x50 , …………………………..do………………………….15x75 , …………………………..do………………………….15x26 , …………………………..do………………………….12x25 , …………………………..do………………………….10x100 , …………………………..do………………………….12x100 , …………………………..do………………………….10x20 , …………………………..do………………………….10x25 , …………………………..do………………………….8x25 , …………………………..do………………………….6x25 , mcb box3 pole havells /anchor , hrc fuse tia 32 amp simens/l&t , hrc fuse tis 63 amp simens/l&t , terminal plate 60 hp ke/simens/bhart bijli , cooling fan 3 hp , slipring resistance box 3 step 7.5 hp r v 140-170 volt , slipring resistance box 3 step 10 hp r v 206 volt , highvoltage syenthetic insulation electric make suitable for , upto 33 kv isi 15652 thk 12mm length 1x2 mtr , spare for 300 amp ocb------ , a- moving arching contactl typetulip/ , b- v bar , c- fix arching contact , d-fix moving contact , amp.96x96mm direct 0-15,amp , ct 90/5ae/l&t , infrared thermo meter max.output1mm 670 mm lenth ledger type , ct 120/5 ae/l&t , ct 180/5 ae/l&t , indicating light lead red 220voltjigo/ae , terminal plate 10 hp , overload reley 25-40 amp simens , stater for 150 hp /110 kw sliparing motor with housing , slipring resistence box 3 step 150 hp r v 330 volt oil immersed , archute 800 ampl&t , amp.meter 120/5 ae/rc/jigo , amp.meter 180/5 ae/rc/jigo , d.spanner set taparia , ring spanner set , box spanner set , contimoty tester with cell , indicating bulb 7 watt 20 volt , change over switch onload 630 amp in ss 4 pole hewlls/semens , auxillary contanct block 3ta24/3ta28 , hexa blead fram h.duty with blaed bosch , nut & bolt with double washer 1/8x1(1 sut) , nut & bolt with double washer 1/8x2(1 sut) , nut & bolt with double washer 1/12x1(1.5 sut) , nut & bolt with double washer 1/12x1-1/2(1.5 sut) , h.duty batterycharger with incloser , musroom push bottan red , h.duty fut switch teknic/jigo , fut switch element l&t/switch , water resistance box for 300 hp , oneway switchhavells/anchor , electronic regulater dinospeed ed currenthavells/anchor , digital magger meco make modle-dit 99 c , clamp meter modle-3690 rishi/mecho , fibre glass tape1” , empire tape 3/4 , c.r.c.2.26 spray bottle, 400 gram ml , fibreglass tape 3/4 , ferrule 25mm2,0-9/0-mm2 , copper strip 2” widthx1/4 , cable gland 3x240mm , g.i. wire 4 swg , cable gland 3x195 mm/185 , bus bar insulator size ½”x8” suman/lby/wingwan , allu bus bor strip 10x5mm2 , hrc fuse n.s. type 16 amp. , glass sleeve size 1mm , glass sleeve but size 2mm , glass sleeve butsize 3mm2 , glass sleeve butsize 4mm2 , glass sleeve butsize 5mm2 , glass sleeve butsize 6mm2 , glass sleeve butsize 7mm2 , glass sleeve butsize 8mm2 , glass sleeve butsize 9mm2 , glass sleeve butsize 10mm2 , h.t.tape size ¾” , h.t.tape but size 1 , battery terminal 12 vote , phase testertaparia make , wooden board 8”x10” , porceline pipe ¾ “x12” , angle holder anchor makehavells , ceiling rose anchor make havells , saddle size ¾ “ , wooden board with sunmica top 9”x12” , power condenser 2.5mfd havells/gc , do but 4 mfd , -----d0------but 4mfd , -----d0------- but 6 mfd , ----- d0------ but 8 mfd , ----- d0------ but 33 mfd , -----d0------- but 100 mfd , c.t.c. , pendent holder k-555 , tube holder bajaj/anchor/havells , condenser 15 mfd,440v/anchor/havells , cotton tape 1” , araldite 180 grms tube , porcelisne s.t. holder 250 , ----- do------ prut 70 watt. , hand lamp complete with lamp , heater &element 150 watt. surya , cotton tape ¾ , s.t. holder 100 watt k-555 , petroleum jolly , exhaust fan,1440 rpm 18 ke / havells , condenser 12 mfd/ lo mfd 250 volt usha make , ----- do--- but 20 mfd , ----- do--- but 30 mfd , soldering wire 18 swg, , white patrol , film paper 10 mile , screw driver set taparia/jhalani , screw driver no.839 taparia/jhalani , screw driver no.832 taparia/jhalani , screw driver no.829 taparia/jhalani , g.i. strip 1/8”x2” ici markedtaparia/jhalani , screw driver no.829 taparia/jhalani make , screw driver no.929 , nose plair size 8” , soldering iron 250 watt. havells/gompton , insulating plair size 8”taparia make , soldering iron 35 watt. wala/mcare , cable 4 loud50 mm2 , ------ d0---- but 120 mm2 , ----- d0------but 185 mm 2 , black tape ¾ , flash type switeh & socket combimed 15 amp.anchor make , s.c.holder 60/100 watt jyoti make , button holder anchor make havells , flash type switch 5 amp anchor mak , flash type switch 5 amp anchor make , metallie carbon bush with tail,grade e-15 size 3/8”x7/8”x1.5” , do but 16x31x40,mm , ----d0—but 12x171x30 mm , ----d0—but 15x20x65 mm , air dry insulatingvarnish dr back make , bactrol gray vanish dr back make , thinner for varnish , tumbler switch porclinebase 15amp.kay make , ---d0----- but 5 amp. , plug top 5 amp. anchor make havells rk , ---d0----- but 15 amp. , metallic carbon bush without tail grade-15 sige ¾”x1”x3” , carbon bus holder brass base for cane unloader dewalt , nicrome wire 20 swg , nicrome wire 23 swg , dioide forward polarity 321,150,ratan shah make jyoti , ---d0---but 321 um100g , flexible pvc capper twin twisted 23/26 2 core vidyut / hemtron national make coil & 91.44 mtr , ---- d0--- but 40/76 , pvccopper wire/lore3/22 nationalmake havells , pvccopper wire/lore3/20 nationalmake havells , pvc copper wire lore3/22 national/vidyut/havells , ---- d0--- but 3/20 , ---- d0--- but 7/20 , ---- d0--- but 7/22 , pvc copper wire,1core7/18 national/vidyut/hemtrox make(coil of 91.44mtrs) , ----do----but 7/20 , workshop flexible wire2 core,40/76,national/vidyut/hemtrox make(coil of 91.44 mtrs) , -----do----but 23/76 , push button switch with element 3-11] 1not 1nc , limit switch type lt/lrgr.no.7-13 ac-11415v 1.5 amp d.c.-11,vaishvion make , multi meter sanwa make small size micho/rishi , limit switch type c.s. 100v, 1nc, 10a,500a ]ac.vaishnomake , proximityswitch as per sample stronger , electronic timer et-100 semens /l&t , ag timer 0-110 sec. terminal l 1+2controlsupply 3+4 instant hours 5+6 delay ete ,double relay , ----- do---- but 0-50 sec. , fuse base & carrir cutout backalite 50a , ----- d0--- but 63 amp , ----- do--- but 15/16 amp , glass fuse 5 amp , indicating lamp pin/serew type 50 voltjigo/ae , holder for indicating lamplamp 3 watt. jigo/ae , mataliecarbon bush with out tail ¾”x1”x3” , ---- d0--- but 8x20x35mm , --- d0—but 16x32x40mm , do---- but.19 x 40 x 50 mm , --- d0--- but 22x32x45mm , pvc flexible copper wire 1-5 mm2yudyt make havells , pvc copper wire 6lare 120/76 double visulated national/anchor , solenoid coil 230 v a/c for s.d. machinerotox/rutork , multi core copper cable 12x115sq mm national/vidyut/hewtron make , power capacitor universal/lot/siemeus make , slipring carbon holder brass frame lcw -250kw-67, rpm-1630, v-rotor v-2287 for spray pond , fixed & moving kit mei make starter type n-2 suitablefor 200 hp motor rating 300/%a 415 v , fix & moving kit for sliring motor startertype osr-10-8 hp-120, v-415] mb1 make , fusebase with cap & gagu ring 63 amp tp. for d.z. type fuse b.l. make , d.z . type fuse 63 amp. , d.ztype ring 63 amp , ------ d0---- but 25 amp , dztype fuse link 63 amp l&t, semens , copper wire swg havells/anchor/polycab , copper wireswg , fuse cop 25/35 amp , fuse cop 63 amp , hrc fuse link d2 type 25amp , -------- d0---but 62 amp , kit kat porciline unit 16 amp , ---- d0---32 amp , d.p. main switch 16 amp 415. standerd makehavells/l&t , ------ d0—but 32 amp , fixed & moving contact rs-15 kilburn make , ----- d0--- but 5d -15 , carbon bush 1.5”1/3/8”) , dztype fuse base tripple pole 415v,63 amp , ------ d0----- 35/25 amp , dz type guagering 35 amp , d2 type fuse 25/35 amp , corbon buse holder for500 hp motor , do for 210hp motor , motor terminal connection plate 40 hp (kec) make , ------- do--- but 60 hp , ---- do---- but 15/25 hp , ---- do---- but 15 hp , moving iron amp meter flash type dia ct operated 600/5 amp aemake , c.t. 600/5 amp af2 make l&t , amp meter pedastal type 0-30 amp to 60 amp , amp meter 300/5 amp size 144x144ae make , volt meter 0-600 amp , amp meter 200/5 amp 96:96 ae make erh/rc , volt meter o-150 size 144x144 ae make , amp meter square mounted 75x75 mm2400 /5 amp ct operated ae make , hylimerod ½ “/ ¾” , mcb 6 amp. mps/ ind.copp 10 amp , k.w. meter range 0-300 ct-400/5 amp 3 pole 415 volt size 144x144 , stay wire , stay insulator ¾”x4” , terminal connector 2-5 mm elemex make , a.c.s.r. conductor , digital multimeter frequency meter make- ae/abb/ l & t. , carbonbushsize100x20x20 mm , ------- d0 ------ but 20x20x20 mm , digital multimeter electronic , model 9a, dmm-18,meea meter pvt ltd. , baokelite fuse (cut-out)63 amp .standard make , ------- do---- but 16 amp , fuse for a.v.r. , slipring 150 kw/100 hpmake ke/l&t , bengin , meggarr 1100 volt motwani i make , hylumsheet ½” , switchgear items itemmake meeho , super enamalled copper wire devidayal/htp/bic , cables lugs dowell’s make , condenser80mfd asian/usha make , fiber glass sheet all size , cotton tape size ½”steel grip , d.c.c. allu wire all size , change over switch 63 amp standard makel & t , -------d0--- but 100 amp , hrc fuse type gsa 50 amp , spare kit sd-15 kilburn make , serew driver 12” taparia male , ------ do---- but 10” , film paper 14 miles lrs/ uokho , soldering iron 65 wattom/rc , soldering wire 21 swg , fixed & moving contract kit r-5,50 hp, 460 v , magnetic coil for spare kit make gikfun / hoby magnet , s.t. holder 300/500 watt jyoti make , pvc copper unarmoured flexible cable 1.5mm*15crore,500v national make 151mark , twin twist copper wire 14/76 2crore 151mark each coil of 91.44mtrs , pvc allu wire 2.5mm 2crore 151mark (coil of 91.44mtrs , lamps &tubescrompton/bajaj make/ ancher , fittings& accessoriies crompton /bajaj make/ ancher , hn type fuse base 630 amp e.e. make om/rc , ------ d0---- but 400 amp , t.p. fuse base d~ type 500 v. 63 amp, bch make , --------- d0------------ but 25 amp , fuse cap for above 63 amp bch. make , ---------- do--- but 25 amp , guage ringfor above 63amp , tpn switch 32 amp havells make/crompton , ------- do------ but 63 amp , power contactor 20 amp 415 v.bch. make , -------- d0------ but 25 amp , --------- d0 ----- but 40amp , no volt coil 20 amp bch. make , ------- d0----- 40 amp , o.l. relay 8 to 13.5 amp bchmake , ------- d0 ---- but 13.5 to 20 amp , slipring assembly asi make for 170 hp motor , heater element 2000 watt best quality , motor cannectionlead , fuse wire 20/25 amp , compensatingcablek type , leatheriesed paper , porcilinkitkat 100 amp , diode w-400,d-170 forwand for weling machine , p.t.bulb 100 watt crompton/ phillips , urica wire 10 sws , amp motor 144x144,0-5 amp dc-75 mv. , amp motor 21/2,0-5 amp dc. , volt meter 21/2x21/2 0-150 vdc , suppressor superstar for 1500 kw alternator , combination plier-8 make taparia , screw driver-8 , crc-226 ml-300/ 400 , multi meter meco , slipring id-73 od-205lenth-142 , proximitly switch 30 vdc , p.t. holderanchor , st holder 100 wattanchor , pvc tape 3/4steelgrip , condensor 2.5 mfd havells , condensor 3.15 mfd havells , condensor 4 mfd havells , condensor 6 mfd havells , proximitly switchdia 18 mm 200 ma/ stronger , smps 240 volt input-24 volt d.c.2.5 amp. omron , push bottan station10 way make ae , condensor 10 mfd havells , glass tape steelgrip , volt meter 4 500 volt , amp meter 4 150/8 amp0 ctr , c.t. 60/5 amp ae/l&t , c.t. 30/5 amp , c.t. 800/5 amp , amp meter 4 60/5 amp ae/rc make , diod 321 farward ruttonsha/ axeit make , diod 321 reverse ruttonsha/ axeit make , clamp meter a/c d/c 1000 amp. , potentio meter 10 k make rc , amp.meter dc-6 0-10 amp. , glass fuse-30 mm 10 mm with fuse , remote push botton set complet. make kamcon , heavy dutty magger 500 watt yokins/ risabh , teflon tape champion , soldring iron 25 watt , amp meter ctr 600/5 amp dia-3.5 ae/rc , carbon brush copper- 21.5 x 32 x 52 , continiuty tester with celltaparia , phase tester taparia , mcb 10 amp. dpanchor/ abb , mcb 10 amp. sp anchor/ abb , mcb 32 amp. tp anchor/ abb , mcb 63 amp. tp anchor/ abb , mcb 6 amp. sp anchor/ abb , mcb 6 amp. dp anchor/ abb , hydaulic thruster for cane unloder , pvc copper sumbersible flate cable-35 mm x 3 core , copper flexible wire-23/76 havells/ rr cable , w/s flexible copper wire-23/76 x 2 core havells/ rr cable , copper wire 2.5 mm x 1 core havells/ rr cable , copper wire 4 mm x 1 core havells/ rr cable , copper lug- 16 mm h.d dowells , copper lug- 25 mm h.d dowells , copper lug- 35 mm h.d dowells , copper lug- 50 mm h.d dowells , alu. lugs- 25 mm h.d dowells , alu. lugs- 35 mm h.d dowells , alu. lugs- 50 mm h.d dowells , alu. lugs- 70 mm h.d dowells , alu. lugs- 95 mm h.d dowells , alu. lugs- 150 mm h.d dowells , alu. lugs- 240 mm h.d dowells , sv choke 250 wattbajaj/ philips , sv choke 400 wattbajaj/ philips , pvc copper wire 1 mm x 2 core rrcable/ havells , led light- 14 watt bajaj/ philips/ cropton , pt. bulb 100 watt bajaj/ philips/ cropton , st bulb-100 wattphilips/ cropton , pvc copper wire 1.5 mm x 2 core havells/ rrcable , pvc copper wire 2.5 mm x 2 core havells/ rrcable , pvc copper wire 4 mm x 3 core havells/ rrcable , pvc copper subnersibile flate cable-35 mm x 3 core , copper flexible wire-23/76 , w/s flexible copper wire-23/76 x 2 core , pvc copper wire 2.5 mm x 2 core , ignitor for s.v. lamp bajaj / surya , s.v. lamp 250 watt bajaj , s.v. lamp 400 watt bajaj
  • View Tender
  • Document
  • Bid Support
17 Security Services
image image
Central Government/Public Sector
TRN :49028195 |  29 May, 2025
Tender Value : 0
 Malda - West Bengal
Tender for auction of condemned/unserviceable stores i.e. spare parts, vehicle tools, tyre, battery , metallic & non metallic , efcc & amn/expl packing material and other items in respect of 12 bn bsf narayanpur, malda srl no. name of items auth quantity remarks 1 printer cable for smart nos 1 2 link encryptor with complete assys, srl no. 247 nos 1 3 24 port managed l-2 switch srl no. 480516320112 nos 1 2 1 5 0 db gain mobile whip antenna with 3 mtr co-axial cable nos 1 6 rm tool kit nos 1 7 rack 19 inch 9u box x800 power strip nos 1 3 4 9 single unit bty charger for mot xirp 8668 srl no. 44/89 nos 1 nos 2 nos 1 nos 1 nos 1 nos 2 nos 1 nos 1 nos 1 13 tx/rx mot uhf motorola gm 300, srl no. 159kbt1516 nos 1 14 tx/rx mot uhf motorola gm 338, srl no. 103tcgd016 & 103tgeg127 nos 2 3 2 16 operator console of 16 line exchange matrix, srl no. m0268-0035668 nos 1 17 sucker and blower (eureka forbes) with complete accessory srl no. 44/01 nos 1 1 1 19 slt card for epabx for matrix exchange nos 1 tx/rx uhf motorola gm 338 srl no. 159kavz690 &159tukz034, tx/rx uhf motorola gm-300 srl no. 159kavz731, 159kbfz918 159kbt1279, 159kbt1439, 159kbf1044, 159kbf1001, 159kbfz936, 159kbfz977 159kavz746, & 159kavz732 22 tx/rx hand held motorola uhf gp 338 s/no. 749tgez654, 749thaf279, 749thaf328 and 749tgf1638 nos 4 tx/rx mot gp 328 uhf srl no. 672hesf922,672hesm772, 672heq9052,672hesn119, 672heq8734,672heys512, 672heys336 & 672tbwn165, awaiting for auction comn branch tx/rx motorola vhf gp 328, srl no. 672tdap880, 672tfge841, 672tdwe561, 672tdar543 & 672tea4662 23 nos 8 20 nos 2 21 nos 10 nos 15 3 db or better gp antenna with uhf female connector nos 12 18 mpsu for lhp 219 with power cable srl no. 1280 & 1586 10 aliminium tublar mast 36 feet with complete assy 11 dot matrix printer lx 800 dx bounty black with assy srl no. 16bua021787, 16bua021752 4 co-axial cable rg 213 ohm 30 mtrs both end connector nos 8 smf bty 12 v 100 ahc amron quanta srl no. 44/15 to 44/21 nos 2 14 1 1 26 signal generator (make - aplab) srl no. 102579 nos 1 6 5 28 push button t/phone m-71 srl no. 12/01 to 15 nos 15 29 magneto telephone make iti srl no. 1115, 1096, 1029, 1125 & 1215 nos 5 30 tx/rx vhf motorola gm 300 with scr srl no. 159tas1446 nos 1 31 tx/rx vhf motorola gp-328 srl no. 672tfge021 & 672tfgc834 nos 2 32 empty drum jwd cable nos 6 33 secondary battery 12volt 100 ahc smf srl no. 12/20 to 12/30 nos 11 34 secondary bty12v ahc smf srl no. 12/01 to 12/07 and 12/10 to 12/12 nos 10 35 tx/rx vhf hand held digital motorola xirp 8668 srl no. 871tqxs507, 871tqxs867 nos 2 36 operator console of 16 line exchange matrix nos 2 37 extension line card slt 32 port 01 with utp cable single end rj 45 nos 1 1 news paper kg 40 2 muster oil/ refined oil 15 ltr tin nos 550 1 steel flask nos 2 2 water jar plastic nos 4 3 serving tray nos 1 4 dinner spoon nos 2 5 slad tang nos 4 6 salt container nos 2 7 katori steel (s) nos 26 8 katori steel (b) nos 36 9 glass steel nos 10 10 case role steel nos 1 1 karahi iron nos 1 2 caculator nos 1 3 wet grinder nos 1 4 jharna bundi nos 2 5 parat aluminium nos 1 6 patila aluminium nos 1 7 aluminium idli maker nos 1 8 steel drum nos 4 9 cello service tray nos 1 wet canteen fund for auction sos mess pvt fund old news paper ration store fund for auction 27 secondary battery 12 v 100 ahc exide srl no. 12/32 to 12/37 & quanta 12/43 to 12/47 nos 24 single unit bty charger nos 25 single unit battery charger for motorola gp 328 nos 10 prestige otg nos 1 1 cartg sig 16 mm white nos 39 235 gm 2 cartg sig 16 red nos 26 156 gm 3 cartg sig 16 mm green nos 26 155 gm 4 mtd ch-1 nos 22 600 gm 5 mtd ch-2 nos 114 3.005 gm 6 trip flair s/pin nos 25 50 gm 7 dye maker grenade s/pin nos 39 208 gm 8 chilly grenade s/pin nos 74 392 gm 9 tear smoke grenade s/pin nos 34 180 gm 10 stun grenade s/pin nos 99 527 gm 11 steel carrier 6a nos 45 12 steel box h2a nos 240 13 steel box b9a nos 2 14 ms steel box nos 4 15 bag canvas 51 mm mor nos 9 16 plastic container 69 a nos 50 17 cwp box (all type) nos 4 sl/no name of head a/u qty 1 almirah (78x34x18) nos 1 2 container 1 k for condoments nos 10 3 hamam dasta iron small nos 1 4 box steel 36x24x18 nos 5 5 emergency light nos 7 6 godrej novtal lock nos 4 7 dry ration box steel nos 9 8 first aid box steel nos 9 9 plastic chair nos 15 10 plastic bucket nos 14 11 harican lamp nos 6 12 water camper 10 ltr nos 7 13 mug plastic nos 4 14 heat piller gopi nos 2 15 revolving chair nos 9 16 filling cabinet nos 1 17 multi hip xercise nos 1 18 prss electric nos 3 19 washer man tub nos 1 20 dustbin plastic nos 2 21 plastic dustbin 40 ltr nos 4 22 baometric finger print machine nos 2 23 body worm camera nos 1 24 brush cutter machine nos 2 25 faratta fan nos 2 26 iron khurpi 5 long nos 4 27 steel container small nos 4 28 steel container big nos 3 29 steel container medium nos 3 30 led tv lg 32 nos 1 unit magazine q branch for auction 31 onida tv 22 nos 1 32 led tv lg 28 nos 1 33 vacume cleaner nos 1 34 loud speaker nos 1 35 aqua guard ro nos 1 36 dining table folding nos 1 37 exide battery nos 2 sl/no name of head a/u qty 1 cgi sheet 10 long nos 32 2 dha iron nos 15 3 picket iron 2 long nos 120 4 picket iron 6 long nos 120 5 spade iron nos 19 6 talwar iron nos 23 7 barwad wire kg 6 8 showal gs nos 9 9 consurtina coil coil 8 10 shovels nos 5 11 water storage 1000 ltr nos 1 12 gi pipe feet 100 13 cgi sheet 8 long nos 2 sl/no name of head a/u qty 1 food warmmer nos 1 2 chair all type nos 51 3 micro ovane nos 2 4 case rool nos 13 5 room heater nos 4 6 heat piller gopi nos 2 7 faratta fan nos 2 8 tv bpl 21 nos 1 9 ro aqua guard 8 ltr nos 1 10 ro system cap 50 ltr aqua fresh nos 1 11 stablizer v guard nos 2 12 led tv 42 nos 1 13 cofee machine nos 1 sl/no name of head a/u qty 1 boot rubber knee pair 102 2 coats steel folding nos 12 sl/no name of head a/u qty 1 tent extendable 4 man nos 7 2 tarpolin 7.5x5.5 nos 12 3 family ridge tent size nos 2 list of un-serviceable items of defense store 12 bn bsf list of un-serviceable items of fire fighting store 12 bn bsf list of un-serviceable items of tentage store 12 bn bsf list of un-serviceable items of barrack property store 12 bn bsf list of un-serviceable items of welfare/grant store 12 bn bsf sl/no name of head a/u qty 1 fire extingusher 9 kg foam type abc nos 8 2 fire extingusher 9 kg abc nos 13 3 fire extingusher 1 kg nos 1 sl no name of items a/u qty 1 modular fan regulator nos 10 2 6 amp socket nos 21 3 6 amp switch nos 23 4 16 amp switch nos 5 5 single phase electric meter nos 2 6 fan bearing 6201 nos 70 7 fan bearing 6202 nos 30 8 2.5 mfd capacitor nos 17 9 16 amp top plug nos 5 10 6 amp top plug nos 4 11 36 swg copper wire nos 3 12 12 volt 88.8 ah secondary battery (7.5 kva dg set) nos 6 13 12 volt secondary battery (bfl dg set) nos 2 14 1200 mm ceiling fan usha nos 4 15 1200 mm ceiling fan khaitan nos 13 16 1200 mm ceiling fan orient nos 13 17 1200 mm ceiling fan usha nos 5 18 1200 mm ceiling fan mie nos 5 19 1200 mm ceiling fan usha diluxe nos 8 20 1200 mm ceiling fan usha nos 6 21 1200 mm ceiling fan mie nos 8 22 1200 mm ceiling fan usha nos 4 23 1200 mm ceiling fan bajaj nos 4 24 1200 mm ceiling fan usha nos 6 25 1200 mm ceiling fan mie nos 6 26 1200 mm ceiling fan usha nos 4 27 1200 mm ceiling fan usha nos 4 28 1200 mm ceiling fan usha nos 20 29 1200 mm ceiling fan mie nos 16 30 1200 mm ceiling fan usha nos 6 31 1200 mm ceiling fan khaitan nos 4 32 1200 mm ceiling fan mie nos 4 33 1200 mm ceiling fan mie nos 4 34 1400 mm ceiling fan khaitan nos 3 35 300 mm exhaust fan nos 6 36 300 mm exhaust fan nos 6 37 300 mm exhaust fan nos 5 38 300 mm exhaust fan nos 2 39 300 mm exhaust fan nos 1 40 7.5 hp submersible motor pump nos 1 41 5 hp diesel engine nos 1 42 10 ltrs geyser nos 1 details of cbp items engg branch naryanpur malda 43 15 ltrs geyser nos 3 44 35 ltrs geyser nos 1 45 20mm gi nipple nos 3 46 cistern box nos 1 47 15 mm pvc tee nos 1 48 15 mm upvc brass socket nos 1 49 pvc connection pipe nos 2 50 250 watt choke nos 12 51 250 watt ignitor nos 25 52 10 amp mcp nos 11 53 33 mfd capacitor nos 2 1 bearing all type nos 24 2 clutch cyl all type nos 3 3 combination nos 1 4 cylinder clutch assembly nos 2 5 clutch plate nos 5 6 door lock assy all type nos 3 7 fog light nos 2 8 chain sprocket nos 19 9 door lifting machine all type nos 1 10 cable all type nos 1 11 door opening catck nos 3 12 fuel filter all type nos 1 13 front disc nos 4 14 fuel tank cap/fuel tank nos 3 15 drive shaft nos 1 16 fuel pump motor nos 6 17 bearing all type nos 18 18 engine mounting and bolt nos 1 19 centre bolt all type nos 5 20 stud for engine cover nut nos 4 21 ignation switch nos 1 22 injector nos 2 23 ignitor nos 2 24 gear assy and gear sleeve nos 2 25 hydraulic adapter clutch cyl t/xenon nos 2 26 king pin bearing all type nos 8 27 rectifier plate nos 4 28 regulator nos 4 29 mounting all type nos 1 30 siren all type nos 1 31 master cylinder assembly nos 2 32 mud guard all vehicle nos 1 33 nut and bolt all type nos 6 34 disc pad nos 1 35 pressure pipe nos 3 36 pressure plate all type nos 2 37 tie rod end assy nos 1 38 realise bearing nos 1 mt us store 39 speedometer senser nos 1 40 speedometer cable nos 1 41 self cabon plate nos 1 42 self assembly all type nos 3 43 shock observer nos 4 44 solnide switch nos 5 45 stereeng uj cross youk & teeth nos 3 46 teie end rod nos 9 47 u j cross nos 24 48 u bolt all type nos 4 49 wheel cylinder all type nos 3 50 rear brake master cylinder nos 1 51 pressure plate nos 1 52 release bearing nos 1 53 oil pinion nos 1 54 insert valve exhaust nos 6 55 insert valve inlet nos 6 56 kit main bearing nos 1 57 kit connecting rod bearing nos 1 58 set pinion piston ring nos 1 59 cylinder liner nos 1 60 water pump nos 1 61 thurmostate nos 1 62 clutch master cylinder nos 1 63 valve inlet and exhaust nos 6 64 pressure transponder nos 1 65 clutch sleeve cylinder nos 1 66 w c assembly r/h nos 1 67 pressure plate nos 1 68 clutch sleeve cylinder nos 1 69 gear fly wheel ring nos 1 70 assy clutch reliase nos 1 71 armature assy nos 1 72 acc cable nos 1 73 drum rear sprocket nos 1 74 ball bearing nos 1 75 ball bearing nos 1 76 spark plug nos 1 77 lever kick nos 1 78 set plate clutch drive nos 1 79 kit pad assy nos 1 80 lock set nos 1 81 chin and sprocket kit nos 1 82 ball bearing nos 2 83 ball bearing nos 1 84 cover assy clutch nos 1 85 bearing assy clutch nos 1 86 disc assy clutch nos 1 87 seat sub assy shift nos 1 88 bearing radial ball nos 1 89 ring nos 1 90 battery size 800ah/700ah nos 8 91 battery size 65ah nos 1 92 battey size 880ah nos 2 93 battery size 150 ah nos 5 94 battery size 9 ah nos 8 95 battery size 12 volt 9ah nos 1 96 tyre size 750x16 nos 16 97 tyre size78x15 nos 5 98 tyre size 900x20 nos 2 99 tyre size 90x90x17 nos 6 100 tyre size 110x80x17 nos 7 101 tyre size 325x19 nos 1 102 tyre size 215x75 r-15 nos 4 103 tyre size 900x20 nos 3 104 tyre size 215/75r-15 nos 8 105 tyre size 245-75 and 235-75 r16 nos 13 1 burnt oil(without barrel) ltrs 945 1 jack and handle nos 1 2 wheel wrench nos 1 3 jack with handle nos 1 4 wheel wrench nos 1 5 ring spanner (10 pcs) set 1 6 d e spanner (10pcs) set 1 7 cutting player nos 1 8 screw driver nos 1 9 grease gun nos 1 10 hammer with handle nos 1 11 jack with handle nos 1 12 chisel nos 1 13 t p gauge nos 1 14 file flete nos 1 15 oil can nos 1 16 wheel wrench nos 1 17 tommy bar nos 1 18 d e spanner (10pcs) set 1 19 screw driver nos 1 20 jack nos 1 21 cold chisel nos 1 22 valve die nos 1 23 inspection lamp nos 1 24 t p gauge nos 1 25 ring spanner (10 pcs) set 1 26 tyre lever set 2 27 cutting plier nos 1 28 wheel wrench nos 1 29 tommy bar nos 1 30 jack with handle nos 1 31 cutting plier nos 1 32 file flete nos 1 33 inspection lamp nos 1 34 chisel nos 1 35 oil can nos 1 36 valve die nos 1 37 tyre lever set 2 38 ring spanner (10 pcs) set 1 39 d e spanner (10pcs) set 1 40 hammer nos 1 41 ring spanner nos 1 42 tommy bar nos 1 43 jack and handle nos 1 44 screw driver nos 1 45 ring spanner (10 pcs) set 1 46 d e spanner (10pcs) set 1 47 cutting plier nos 1 48 screw driver nos 1 49 hammer with handle nos 1 50 chisel nos 1 51 file flate nos 1 52 oil cane nos 1 53 vale die nos 1 54 tyre lever nos 1 55 tool box iron nos 1
  • View Tender
  • Document
  • Bid Support
18 Railway Transport
image image
Central Government/Public Sector
TRN :49029654 |  14 May, 2025
Tender Value : 0
 Bhopal - Madhya Pradesh
Tender for auction sale of scrap old iron and steel of cond. coach with or without minor wood, decorum and non-ferrous attachment. (loose wood, decodum, non-ferrous & restricted items will not be delivered) coach no sec 02626 camping note : 1. advance handing over of coaches for cutting may be allowed. 2. before commencing of delivery of lot, all the restricted items shall be handed over to sse/yard and cutting shall be completed before commencing of delivery.(qty.16mt approx. each) s.b.lot no.bpl/crw s/25-26/cond. coach/04/0033 restricted items: bogie items: complete trolley including following items:- wheel set with axle box & roller bearing, axle box spring & bolster spring, brake gear fittings, bronze wearing pieces, bolsters, suspension link, wearing plate, l.s. beam, equalizing stay with pin, draw bar hook, draft link with nut, draft key, screw couplings, buffer casing, buffer plunger with spindle, center pivot pin, etc. furnishing and carpentry items: window shutters, aluminum window frames with glass, sealed window glass, seats and berths of ac & non ac coaches, unified ss inlay, wash basin, aluminum water tank (over head, under slung etc), water taps ( metallic),wall protector etc. air brake items: distributor valves, control reservoir with common pipe brackets, air brake cylinder, dirt collector, check valve with chokes, angle cocks, isolating cocks, auxiliary reservoirs, pressure gauge, pev, peasd, guard emergency valve etc. electrical items: alternator, rru/erru, fan, battery cell, battery box, tube lighting fitting, night lamps, emergency lights, compressor, , condenser, evaporator unit, pre cooling transformer, condenser/ blower motor, seat indication lights, wash basin lights, cable, laptop/mobile charging points, ac control panels, rmpu units, 25 kva inverter etc
  • View Tender
  • Document
  • Bid Support
19 Educational And Research Institute
image image
Boards / Undertakings / PSU
TRN :48996540 |  13 May, 2025
Tender Value : 1.47 Crore
 Matunga - Maharashtra
Tender for repair, renovation, and reconfiguration of lab 1 at the computer engineering and it engineering department, first floor, vjti, matunga, mumbai.= 1 dismantling of existing partitions, wall paneling, etc., all complete as per site requirements, and stacking the usable materials within building premises as directed by the architect/consultant/ engineer-in- charge, etc. complete. (lead upto 100 meters) 2 removal of cement tiles, existing flooring, wall tiles,marble, polished shahabad flooring, dado with or without bed concrete, including stacking the materials as directed, with all leads, lifts, etc., complete. (lead upto 100 meters) 3 dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. complete. ( lead upto 100 meters) 4 scraping the old paint from the plastered internal surface using a dust-free vacuum paint scraper, followed by coating the entire surface with a mixture of whiting or glue and linseed oil, including the provision of scaffolding, as directed. (the scraping of old paint should be done until the neeru finish of the plaster is achieved.) lead and lift upto 100 meters etc. complete. 5 removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. 6 removing the existing cement plaster of any thickness without causing dust nuisance, stacking the debris up to a distance of 100 meters, cleaning the site, etc. complete. 7 providing and applying an anti-corrosive chemical to exposed reinforcement of r.c.c. members such as beams, columns, and slabs. this includes one coat of alkaline rust converter (feovert, rusticide, or equivalent) after cleaning the surface with a wire brush, followed by two coats of anti-corrosive, epoxy-based, two-component, zinc-rich primer (materemaco p 130 of basf, phenolic ipnet rb, polyalk flxoprime, or equivalent) for rebar protection on exposed reinforcement. additionally, apply a concrete-penetrating corrosive inhibitor (epco kp-100, polalk ep 113, masterseal 1414 of basf, fosroc, or equivalent) over the adjoining concrete surface. etc. complete. 8 providing and applying a bond coat of approved epoxy resin (masterbrace 1414 of basf, epi bond of krishna conchem, or equivalent) before polymer plaster or concrete to ensure a perfect bond between old concrete and new concrete/polymer plaster surfaces. the bond coat should be applied within half an hour after preparation, conforming to astm c881 type 2. this process includes the use of nylon brushes, scaffolding, labor, etc. complete. 9 providing and applying ready-mix polymer-modified cement mortar with an average thickness of 15mm, using polymer in one or more layers, in a proportion of 1:5:15 (polymer, cement, and quartz sand) as per the manufacturers specifications. the surface should be cured after 72 hours of application using wet gunny bags, etc. complete. 10 providing and applying ready-mix polymer-modified cement mortar with an average thickness of 30mm-50mm, using polymer in one or more layers, in a proportion of 1:5:15 (polymer, cement, and quartz sand) as per the manufacturers specifications. the surface should be cured after 72 hours of application using wet gunny bags, etc. complete. 11 providing and applying a 30mm thick self-curing ceramic polymer microconcrete of an approved make, having a compressive strength above m30, non-shrink, and impermeable, as a filling mortar for load-carrying r.c.c. members in two layers on cleaned concrete surfaces, including honeycomb areas (using manual or mechanical means). the mortar shall be prepared by mixing nicosil c80 and fresh 53-grade cement with the required water-cement ratio to achieve the desired consistency. the application and finishing shall be done by manual trowelling. curing shall be carried out after the initial setting time, in accordance with the manufacturers specifications. the work shall be executed in line with the specifications and as directed by the engineer-in-charge. the work must be carried out by a certified applicator, and the work shall be guaranteed for 5 years. the guarantee shall be provided on a rs. 500/- stamp paper. (the bond coat, as per item no. 08 in the boq, is to be applied before the coating.) 12 providing and applying 12mm thick internal/external ready-mix plaster conforming to is: 4031 (part-4) 1988 and is: 383-1970, in a single coat using cement mortar in a proportion of 1:4, with a special type of polymer additive (approximately 0.4%), on all types of surfaces in all positions, including scaffolding and curing. the plaster shall be followed by a smooth finishing coat of gypsum plaster of 6mm thickness, ensuring an even, smooth surface suitable for painting. complete with necessary curing, scaffolding, and all other related works. 13 providing and applying a priming coat over new/old steel and other metal surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter. the surface shall be scoured with wire brushes, fine steel wool, scrapers, and sandpaper, with scaffolding as required, etc. complete. 14 providing and applying priming coat over new wood and wood-based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter, sanding, knotting, scaffolding, etc., complete. (brands such as asian paints, dulux paints, nerolac, berger, royal, or equivalent make.) 15 providing and applying two coats of synthetic enamel paint of approved color to new/old structural steel work and woodwork in buildings, including scaffolding if necessary, cleaning, and preparing the surface (excluding primer coat). etc. complete.(brands such as asian paints, dulux paints, nerolac, berger, royal, or equivalent make.) 16 removing and refixingof doors and windows with frames and stacking the materials as directed, including all leads, lifts, labour, fitting etc., complete. (lead up to 100 meters) 17 providing and laying in pattern 600 mm x 600 mm vitrified tile flooring of 8 to 10 mm thickness and confirming to is 15622-2006 ( group bla) of approved make,quality, shade and pattern for flooring . the tile flooring shall be laid in pattern with 2 mm spacers & tiles fixed in cement mortar of 1:4. the rate shall be including floor chipping to attaining required levels, epoxy grouting of joints using approved matching colour tile grout of epoxy grout, necessary protection of the laid floor, acid wash cleaning for any stains before handover. etc. complete as per the drawing, specification and to complete satisfaction of the engineer. rate to include the wastages as per the pattern indicated in the layouts. brands like kajaria, johnson or similar etc. groove shall be filled with grout of approved shade ( brands like laticrete etc.) as dicectedby the engineer-in-charge. etc. complete. basic rate for tile material- rs. 1440/- per sq.m. 18 providing and fixing skirting, including labor, materials, and all related work, etc., complete. rate for skirting of height up to 150 mm. 19 vinyl flooring for hod cabin:providing and fixing approved color homogeneous flooring, 4mm thick with interlocking system, single-layered flexible spc vinyl flooring (spica by tusker vinyl floorings) in roll form, over the provided i.p.s. or kota stone flooring. the flooring will be fixed using approved adhesive, and all joints will be soldered with pvc rods as per the manufacturer’s specifications. the work will be completed as directed, ensuring proper leveling and cleaning. the roll width will be a minimum of 2.0 meters, and the weight of the pvc flooring will be 90 kg per 30 sqm. as directed and approved by engineer in charge. etc complete. basic rate for vinayl flooring material- rs. 900/- per sq.m. 20 providing and laying vitrified mirror/glossy/matte finish tiles of size 590 mm to 605 mm x 590 mm to 605 mm with a thickness of 8 to 10 mm, conforming to is 15622:2006 (group b1a) from an approved make, shade, and pattern, for dado and skirting in the required positions. the tiles shall be fixed in 1:4 cement mortar, including neat cement float, filling of joints, curing, cleaning, and all related work, etc., complete. basic rate for tile material- rs. 790/- per sq.m. 21 providing second-class burnt brick masonry with conventional/i.s. type bricks in cement mortar 1:6 in the superstructure, including striking joints, raking out joints, watering, scaffolding, and all related work, etc., complete. 22 lowering the debris obtained from breaking and removing cement plaster/burnt brick masonry from the first floor by any means, without causing dust nuisance or damage to the structure. the debris shall be stacked as directed by the engineer-in-charge, including cleaning the site, etc., complete. (lead up to 100 meters.) 23 removing and disposing of debris from the site to a dumping ground outside the vjti premises (in accordance with municipal rules), etc. complete. as directed by the engineer-in-charge. (minimum 6 cu.m debris per trip) 24 providing anti-termite treatment to the wooden frames of doors and windows of the existing building as per i.s. 6313 (part-iii), by drilling 6 mm dia. holes at the four corners on one side and the four corners on the other side, at a downward angle of approximately 45 degrees at the junction of the woodwork and masonry. injecting 150 ml of chlorodane 5% w.c. into each hole and sealing with putty, etc., complete, with a 2-year guarantee on bond paper. 25 providing and applying waterproof melamine polish of the required finish to the woodwork by spray machine, including knotting and preparing an even surface by scraping, applying french polish, scaffolding if required, etc., complete.note: the work is to be executed only with prior approval from the superintending engineer. (brands such as asian paints, mrf melamine or equivalent.) etc. complete. 26 providing and fixing ss t/u/l strip profiles for walls, ceilings, tiles, flooring, main doors, interior decoration, bathrooms, and living rooms, including transportation, wastage, labor, etc., complete.shape: t/u/l profilematerial: ss 304 grade stainless steeldimensions: 8 mm to 12 mmlength: 2440 mm (8 feet), 3048 mm (10 feet)type: t-sectionfinish: polishedposition: interiorcolor options: gold, rose gold, black, silver, champagne, antique hairline, antique copperthickness: 2 mm to 8 mmnote: the shape, pattern, color, and design will be directed by the architect/consultant/or engineer in charge. basic rate for material- rs. 850/- per number. 27 providing and fixing ss t/u/l strip profiles for walls, ceilings, tiles, flooring, main doors, interior decoration, bathrooms, and living rooms, including transportation, wastage, labor, etc., complete.shape: t/u/l profilematerial: ss 304 grade stainless steeldimensions: 16 mm to 32 mmlength: 2440 mm (8 feet), 3048 mm (10 feet)type: t-sectionfinish: polishedposition: interiorcolor options: gold, rose gold, black, silver, champagne, antique hairline, antique copperthickness: 2 mm to 8 mmnote: the shape, pattern, color, and design will be directed by the architect/consultant/or engineer in charge. basic rate for material- rs. 850/- per number. 28 providing and fixing sign boards foor doors:specification for waterproof signage boards (12 x 4 inch)size: 12 inches (l) x 4 inches (h) (with size tolerance is plus or minus 1%)material: high-quality, durable acrylic or pvc boardfinish: glossy or matte finish for clear readabilitywaterproof: weather-resistant, suitable for both indoor and outdoor usedesign: custom text, graphics, or logo engraving/printingmounting: wall-mountable with adhesive backing or screw mountscolors: available in multiple colors with contrast for visibility (e.g., white, black, silver)application: ideal for office cabins, rooms, labs, and other signage needsthis durable, waterproof signboard ensures clear and professional signage in various environments. including wastage, etc. complete. basic rate for material- rs. 460/- per number. 29 providing and fixing of 3d wall panels that can be painted as well.size of each panel: 2 x 2 feet.colour: any color, design, or pattern.features: lightweight, fire-resistant, easily diy, 100% recycled.made from natural bamboo plant fiber, etc., complete. basic rate for material- rs. 450/- per number. 30 providing and fixing wooden decorative fluted wall panels/louvered wall panels:material: high-quality wood (mdf, plywood, or hardwood) with a decorative veneer finish.dimensions: 8 feet x 4-5 inchesthickness: 8 mm - 12 mmdesign: fluted design with vertical or horizontal grooves for a decorative effect.color: multicolor/any colour. (customizable to match interior themes).shape: rectangular panels for seamless installation, etc., complete. basic rate for material- rs. 850/- per number. 31 providing and fixing machine cut mirror polished 16 mm to 20 mm thick telephone black / amba white / cat bary brown / rbi red / ocean brown granite stone partition with rounding the edges etc. complete. one side polishbasic rate for granite material- rs. 2530/- per sq.m. 32 providing and fixing oval-type under-counter wash hand basin of 16-inch x 22-inch size and of special color shade, having telephonic black/colored granite of 180mm thick stone black kadappa framework, including chromium-plated coupling bottle trap. the wash basin should be of cera company or equivalent, model no. 3448, as per the detailed drawing or as directed by the engineer-in-charge, etc., complete. (counter size 1.20m x 0.60m). (brands such as jaquar,kohler or equivalent make.) basic rate for wash basin - rs. 6000/- per number. 33 providing and constructing a granite kitchen platform with the installation of a stainless steel sink (600mm x 450mm) as per the detailed drawing, including vertical polished kadappa stone supports (25 to 30mm thick) on both sides, with a kadappa top (35 to 40mm thick) and a polished granite top (16 to 20mm thick). the platform will feature granite strips at the front and both sides, with two vertical granite supports (15 cm height). the top granite will be 75 cm x 40 cm, including cutting and opening for the sink of the required size in both kadappa and granite. the platform size is 5.00 m x 0.60 m, with a height of 0.75 m, etc. complete with all required finishing. basic rate for ss sink- rs. 6000/- per number. 34 supply and installation of 600x600mm modular metal perforated grid ceiling system (cg-01)the ceiling system shall be supplied and installed as per the specifications provided in the tender document, and in accordance with the directions and approval of the engineer-in-charge. the scope includes complete installation with all necessary materials, components, and finishing to ensure proper execution etc. complete. 35 providing and installation of aluminum frame works for partition with ply on both sides and laminate finish: providing and fixing partition aluminum frame work consist of 25mm x 50mm x 1.2mm thick extruded aluminium box section framework at spacing not exceeding 600mm centre to centre both ways (horizontal and vertical). the framework shall be secured at floor structural ceiling and sill/ lintel level with 25 x 50mm x 1.2mm thick horizontal aluminium section. framework to be secured to floor / walls / columns / ceiling / beams using 75mm metal screws and dowels.acoustic infill: providing & fixing acoustic insulation of approved make to g.i./ aluminum/ ms/ wooden frame partition of 50mm thick rockwool of density 48 kg/m with blanket wrapped in rp tissue suitably affixed to partition framework using where necessary gi binding wire duct tape as indicated in the drawing.outer skin:- providing and fixing 18mm plywood of brands like greenply, century or equivalent. finished with 1 mm thick laminate of approved shade applied on plywood of brands like formice, royal touche or equivalent brand.note: rate is as per aluminum framework with both side ply and laminate. etc. complete. 36 providing and fixing of laminate cladding with ply backing:providing and fixing 12mm bwr plywood (brand: greenply, century, or equivalent), directly fixed to the column. a 1mm thickness laminate of an approved shade, applied on the plywood surface. laminate brands: formica, royal touche, or equivalent. etc complete. 37 providing and installation of glass partition (toughened glass): providing 12mm toughened fixed glass partition including all patch fittings, ensuring smooth and even flush joints between glasses, fixing the same in positions to true line and level, finishing the wall joints with clear silicon sealants, cleaning the surface and ensuring that there are no scratch marks on the glass etc. complete as per drawing and specifications, glass brands should be dorma, ozone or equivalent. 38 providing and installation of glass partition (dgu glass): double-glazed unit glass with air spacer of 6 to 16mm, 95% transparency, etc. complete as per drawing and specifications, dorma or ozone or equivalent. 39 providing and installation of 12mm thick clear toughened glass door with film as required. (d2 - 0.91 x 2.10 m) specification:hardware: door to be complete with hardware to each leaf as follows: hinges: 8 nos. ss ball bearing butt hinges. door closer: concealed door closer with hold open. lock set: dead lock as approved.door handles:900mm ht. 36mm dia d type offset handle on both sides in approved powder coating. door stop: floor mounted door stopper as approved seals: drop down floor seal as approved. security system: na note: all the metal profile sections and hardware finish should match the frame. brands like dorma or ozone or equivalent. etc. complete as per drawing and specifications. 40 providing and installation of d1 - double door two-way sliding motorized door, suitable for door openings up to 1.20 meters with a maximum door weight of 100kg (both leaves). the door offers environmental protection with a working temperature range of -20°c to +50°c and is rainproof. it has a standard opening time of 3-8 seconds, with a remote control operating distance of 100 to 200 feet (depending on line of sight). the opening size is 2.4m x 2.10m, and the glass door size is 1.2m x 2.10m. brands like dorma, ozone, or equivalent, to be installed as per drawing and specifications. etc. complete. 41 providing and installation of d3 - 1.09m x 2.10m (single shutter) 12mm toughened glass door with fixed side panels, including all patch fittings, locking mechanisms, and ensuring smooth, even flush joints between the glass panels. the door is to be fixed in position to true line and level, with wall joints finished using clear silicone sealant. the surface should be cleaned and inspected to ensure there are no scratch marks on the glass. installation to be completed as per drawing and specifications, with brands like dorma, ozone, or equivalent. etc. complete. 42 pop punning: providing and applying of plaster of paris punning(1st quality isi approved pop) over plastered with minimum thickness of 8mm-12mm to existingwall surfaces, ceilings & concrete members etc., to be finished in line and plumb with smooth surface ready to receive paint base. rate to be inclusive of edge protection (gi), fibre mesh for service conduits,hacking wall surfaces for better bonding, cleaning, scrubbing the surface, providing grooves if necessary etc., complete as per architects/consultant/engineer-in-charges approval. brands like gyproc, armstrong, shera or equivalent etc. complete. 43 plastic emulsion paint (leed compliant, low voc): providing and applying plastic emulsion paint finish to walls, partitions, and ceiling surfaces of approved make, color, texture, and shade in two coats, with surface and finish acceptable to the engineer in charge to be achieved within these two coats. any additional coats, if required, shall be at the contractors cost. the work includes preparing existing surfaces by scraping away loose particles, dust, etc., washing and scrubbing, filling cracks with crack filler and binder, cleaning and making the surface dust-free, applying water-based rj london putty as directed, rubbing with sandpaper to smooth the surface, and applying one coat of primer as recommended by the approved paint manufacturer. the work also includes providing necessary scaffolding, cleaning, and protecting the site until handover, as well as masking and protecting all service devices such as switchboards, detectors, etc. the work is to be completed at all heights and leads, as per specifications or as directed by the architect/engineer in charge/consultant. brands like asian paints, berger, or equivalent are acceptable. etc. complete. 44 providing and applying premium decorative wallpaper high-end or custom designs (special finishes, custom patterns)specifications: material: non-woven fabric or vinylroll size: 21 inches wide x 33 feet long (covers 55 sq ft)pattern: various styles (floral, geometric, etc.)finish: matte, gloss, or texturedinstallation: peel & stick or pastefeatures:scratch & water-resistanteasy to clean (wipeable)fade-resistanteco-friendly, voc-freeideal for: living rooms, offices, and accent wallsmaintenance: clean with a damp cloth, no harsh chemicalscustom options: available in various colors and patterns, custom designs upon request. basic rate for wallpaper rs. 600/- per sqm. 45 standing platform (300-450 mm from ffl):construction of a standing platform at a height of 300 mm to 450 mm from the finished floor level (ffl), as per approved dimensions. the platform will be made of 18 mm thick wood (century, greenlam, or equivalent) and finished with wood polish (asian paint wood tec, mrf, or equivalent).materials:frame: mild steel or aluminum, powder-coated for corrosion resistance.surface: high-quality plywood, mdf, or approved materials with a non-slip finish.support: sturdy metal beams or supports for stability.features:height: 300 mm to 450 mm from ffl, as per design.finish: non-slip surface with smooth edges and protective coating.safety: non-slip tread and optional guardrails. etc. complete. 46 stage flooring: supply and installation of interlocking rubber tile flooring at the stage area as per the specifications and drawings provided. the flooring will consist of a 6.0 mm synthetic sport surface, including a =1.50 mm pur protect® treated vinyl surface layer, calendared and grained, supported by a pvc density single closed-cell foam, and reinforced with a fiberglass grid structure. it will feature sanosol treatment for fungistatic and bacteriostatic properties. the flooring will meet the following standards: weight: 3.7 kg/m², impact resistance (en 1517) =8 n/m, abrasion resistance (en iso 5470-1) =350 mg, shock absorption (en14808) =25% (labosport result = 28%), indentation resistance (en 1516) =0.5 mm, ball bounce (en 12235) =90%, vertical deformation (en 14809) =3.5 mm, sliding coefficient (en 13036-4) 80–110, fire (en 13501-1) cfl-s1, anti-viral activity (human coronavirus 229e) – iso 21702 (99.37% after 2 hours), energy return (nf p 90 203) =0.31 m/s, tvoc after 28 days <100 micrograms/m³ (iso 16000-6), floor score®, ce marking, en14904 compliant for multi-sports use, reach compliant, and singapore green label certified. the supply and installation will include making good any damaged surfaces using standard fillers such as birla white cement, cement-based grout, epoxy grout, or mortar, and repainting to match the color.all work will be completed in accordance with the specifications, design, drawings, and the direction of the engineer-in-charge. 47 providing and fixing of overhead storage as per the specifications and drawings provided in the tender document. etc. complete. 48 providing and fixing of surface storageas per the specifications and drawings provided in the tender document. etc. complete. 49 providing and fixing on-site a lab table as per the specifications and drawings provided in the tender document. etc. complete. 50 providing and fixing of office desk/table in faculty lounge as per the specifications and drawings provided in the tender document. etc. complete. 51 providing and fixing of office desk/table in office for hod as per the specifications and drawings provided in the tender document. etc. complete. 52 supply and installation ofhod cabin chair as per the specifications and drawings provided in the tender document. etc. complete. 53 supply and installation of faculty lounge chairs as per the specifications and drawings provided in the tender document. etc. complete. 54 supply and installation of study chairs for labs as per the specifications and drawings provided in the tender document. etc. complete. 55 supply and installation of foldable desklet tables for the seminar hall as per the specifications and drawings provided in the tender document. etc. complete. 56 removingthe exisitng light fixures, fans, wires, cables, swith boards and distribution boards etc. complete. 57 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm (2+1e) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg-pw/sw. (brands for conduits precision/finolex/pressfit. and for cable barnds should be polycab/finolex/havells. etc. complete 58 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 2.5 sq.mm (2+1e) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg-pw/sw. (brands for conduits precision/finolex/pressfit. and for cable barnds should be polycab/finolex/havells. etc. complete 59 supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a / 25a switch combined with indicator lamp and fuse with gang box on wooden board.make /brand (roma/ legrand,/ greatwhite) etc. complete 60 supplying and erecting isi mark modular type 3 pin 6a / 16a multi socket with safety shutter, duly erected on providedplate and box with wiring connectionsetc.complete. brand : roma/gretwhite/legrand) etc. complete 61 supplying and erecting pvc surface modular double mounting plate 3 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) 62 supplying and erecting pvc surface modular double mounting plate 4 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 63 supplying and erecting pvc surface modular double mounting plate 6 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 64 supplying and erecting pvc surface modular double mounting plate 8 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 65 supplying and erecting pvc surface modular double mounting plate 12 modules complete duly erected etc complete.(.brand roma/gretwhite/collar) etc. complete 66 supplying and erecting regular/ standard model ceiling fan of 1400mm with sweep complete erected in position as per specification no. fg-fn/cf brand /orient/polycab/crompton etc. complete 67 supplying and erecting flush-type ceiling fan regulators and electronic step regulators for ceiling fans (600mm, 900mm, 1200mm, and 1400mm sweep), complete with installation on the provided switchboard. make/brand: roma, legrand, or greatwhite. 68 providing and fixing 36 watt 2x2 light fitingsupplying and erecting square shaped crca /die-cast aluminium powder coated housing led panel light (slim edge-lit) 600x600mm suitable for 36 w-40w includingmotion sensor led light with provision for plane front frame with translucent cover fixed to the housing etc.complete .brand philips/havels/wipro etc. complete 69 supplying and erecting 16 to 32 a dpmcb suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 70 supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (24 poles) or tp mcb of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb1 (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 71 providing & erecting 3 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/tripalarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb (make/ brand: legrand/ schneider/ l&t/ indo asian) etc. complete 72 supplying, erecting & commissioning 4 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw-rccb/rccb. (make/ brand: legrand/ schneider/ l&t/ indo asian) 73 supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg-tw etc. complete. cables brands should be polycab/finolex/havells. etc. complete 74 supplying and installing cat-6 cable suitable for networking as per specification no. wg-coc/nc. cables brands should be polycab/finolex/havells. etc. complete. 75 supplying & erecting mains with 2 x 2.5 sq.mm. and earth wire 1.5 sq.mm frlsh pvc copper wire in hms pvc conduit min. 20mm dia. as per specification no: wg-ma/pc.etc complete. brand :polycab/finolex/havels) etc. complete 76 supplying, erecting & terminating xlpe armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.cb-lt/cu(brand: polycab/ finolex/ havells)note - the quantity of wires for looping the required number of air conditioning units has to be calculated by the contractor with respect to the provided architectural working drawing. etc. complete 77 providing & erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) gi sheet of 150 mm width & 20 mm height complete with necessary hardware. cable tray brands should be profab or equivalent. etc. complete 78 supplying and erecting pvc box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification no: wg-ma/box. etc. complete (make/ brand: legrand/ schneider/ l&t) 79 supply & fixing of aluminum box section to be laid on the floor with all excavation, re-cementing & refinishing civil works to make good in line with the existing floor level respective junctionbox to be fabricated in 16 swg gi sheet with cut out as required for terminating the box sections. shall include pvc conduits from jb to work station powerpoints i)150 x 150x 50 mmgijunction box with cover & cut outs etc. complete. (make/ brand: legrand/ schneider/ l&t) 80 supply of a.c split unit (2 ton) :supply of ac split unit as per the specifications, and drawings provided in tender document. make (carrier/ voltas/ bluestar/ samsung) etc. complete 81 supply of 2 ton casatte ac:2 ton inverter casette ac. cooling capacity 3200-8000 watt. offers uniform 360 degree round airflow, with 4 star energy rating. etc. complete. make (carrier/ voltas/ bluestar/ samsung) etc. complete 82 installation of 2 ton ac split unit etc. complete 83 installation of 2 ton ac cassette unit etc. complete 84 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigerant having 22swg thickness and inner dia/size 22mm complete. etc. complete. material selection should be high quality and from reputed brand as directed by engineer in charge. 85 supply & installation electrical communication cable between indoor to outdoor units.cables brands should be polycab/finolex/havells. etc. complete. 86 providing and fixing in position ms frame stand for a.c. units, floor or wall mounted, with vibration isolation pads and frame to be made out of required ms sections strong enough to hold the weight of the ac unit,and should be lockable, including fixing in position using necessary scaffolding, ladder etc, and painting with two or more coats ofapproved enamel paint on a coat of red oxide etc. complete 87 insulated condensate water drain piping constructed out of pvc / hdpe hard pipeswith 6mm thick nitride insulation, fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors fasteners and concealed in brickwork or flooring. etc. complete(make: finolex/ astral/ prince) 88 supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided pc / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/ac system. etc. complete. material selection should be high quality and from reputed brand as directed by engineer in charge. 89 supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 20a, 2 pin plug & earth socket and 20a, 3 pin plug top with 20a/30a single pole mcb having rated short - circuit breaking capacity (icn) 10ka complete erected on angle iron/ gi frame. etc. complete 90 carrying out core cutting of size 3 to 5 dia x 15 length in the c.c./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. etc. complete 91 supply and installation of roller blindsas per the specifications and drawings provided in the tender document. etc. complete. basic cost for blind cloth fabric material rs.900/- per sq.m. 92 carrying out test for ceramic tiles / vitrified tileswater absorption, modulus of rupture (set of 6 tiles) etc. complete. 93 carrying out test for plywood: determination of resistance to dry heat,determination of moisture content,determination of density,thickness of plywood. etc. complete. 94 carrying out test for test for glue adhesion for plywood etc. complete. 95 carrying out test for hollow / solid /aac blocksdensity test. (set of 3 blocks), compressive strength. (set of 3 blocks), water absorption test (set of 3 blocks) etc. complete. 96 providing and fixing 15 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 97 providing and fixing 20 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 98 providing and fixing 25 mm dia. cpvc pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. this includes removing the existing pipeline if necessary, conveying, and stacking the same in the pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 99 providing and fixing on walls/ceiling/floor 32mm dia cpvc pipe with necessary fittings, remaking good the demolished portion, etc., complete. including removing existing pipeline if necessary and conveying and stacking the same in pwd chowky or as directed, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 100 providing and fixing 75 mm dia stabilizer pipe/p.v.c. soil vent/waste pipe with necessary fixtures and fittings, such as bends, tees, single junctions, slotted vent, clamps, etc., complete. 101 providing and fixing 100 mm dia stabilizer pipe/p.v.c. soil vent/waste pipe with necessary fixtures and fittings, such as bends, tees, single junctions, slotted vent, clamps, etc., complete. (brands such as astral, finolex, prince or equivalent make.) 102 providing and fixing 10 cm pvc nahani trap with grating, etc., complete. (brands such as astral, finolex, prince or equivalent make.) basic rate for nahani trap is rs. 380/- 103 providing and fixing c.p. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. basic rate for pillar cock is rs. 1250/- per number 104 providing and fixing of exhaust fan 150mm crompton/havels/usha or equivalent etc. complete. basic rate for exhasut fan is rs.1000/- per number 105 providing and fixing stainless steel round napkin hanger for bathroom/towel holder for wash basin/napkin holder/bathroom (chrome) b. heavymaterial stainless steel product dimensions 17l x 5w x 19h centimetersfinish type chromeinstallation type wall-mounted shape round including fitting etc. completed.basic rate for material is rs. 320/- 106 providing and fixing premium front glass shelf - bathroom shelf/kitchen shelves wall mounted with frosted and toughen (tradition 6 x 18) chrome including fitting etc. complete. basic rate for material is rs. 650/- 107 providing and installation of 6 mm thick mirror with 6 mm thick ply backing, as per design. the mirror will be supported by stainless steel finished buttons, etc., complete. (the glass brand should be saint-gobain, borosil, or an equivalent make) basic rate for mirror is rs. 1250/- per sq.m. 108 supply and installation of nsd make smoke detectormodel:66a, certification: ce & ertl etc. complete. 109 supply and installation of nsd make heat detectormodel:66h, certification: ce & ertl etc. complete. 110 supply and installation of response indicator make: nsdmodel: p.s (mini) etc. complete. 111 supply and installation of manual call point (m.s) make nsd 112 supply and installation of 08 zone fire alarm panel make nsd(excel) etc. complete. 113 supply and installation of flasher hooter make nsdmodel no: ms17flash etc. complete. 114 supply and installation of supply & laying 1.0 sq. mm x 2 core copper armored isi cable for alarmsystem. with accessories per meter. brand/make :polycab/finolex/havellls) etc. complete. 115 supply and installation of high quality co2 fire extinguisher (6 kg)type:carbon dioxide (co2) fire extinguisher (for electrical fires and flammable liquids)capacity: 6 kgfire rating: class b (flammable liquids) class c (electrical fires)material: cylinder: steel or aluminum alloyfinish: red powder-coated for durabilityoperating pressure: 55 bardischarge time: approx. 8-10 secondsdischarge range: 3-5 feettemperature range:operating: -10°c to +60°c storage: -30°c to +60°cmounting: includes wall bracket certification: is 15683 (india) / ul/ce certified etc. complete.note: the rates for all fire safety alarm items include the complete supply, installation, commissioning, transportation, freight, and all associated costs. 116 providing architectural/ interior design services : scope of work as below:drawings preparation: 3d views, floor plans, furniture layout, electrical layout, ceiling layout, and partition layout.color scheme & material selection: guidance on colors and material choices for finishes, flooring, and furniture.quality control: ensure standards for structural, civil, electrical, fire safety, furniture work and hvac work.interior planning: optimize lab functionality and aesthetics, including furniture, partition design, and system planning (electrical, hvac, fire safety).modifications: suggest changes to designs based on site conditions and client feedback.coordination & monitoring: ensure project progress and timely completion by working closely with contractors. deputation of interior designer degree/diploma/certificate course having knowledge of autocad and 3d home or equivalent for the full period of the work. designes. monitor on-site execution, ensuring design adherence. taking joint measurements.preparing statements for extra items and excess quantities.compliance & safety: ensure adherence to safety codes and regulations. etc. complete.
  • View Tender
  • Document
  • Bid Support
20 Agricultural And Floriculture And Silviculture Products
image image
State Government
TRN :48937513 |  10 May, 2025
Tender Value : 26.17 Lacs
 Nagpur - Maharashtra
Tender for supply and installation of furniture and allied electrical work at msambs division office, nagpur.2 providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm, 1.5 mm thick with 12 mm thick three layered flat pressed teak wood particle board bonded with bwp type exterior grade phenol formaldehyde synthetic resin conforming to is 128231990, laminated on both sides,novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubber cushioning beading to glass partitions, with wood boxing to all aluminium tubuler section as per approved drawing etc. compete(as directed by engineer-in-charge) 3 providing and fixing in position, single shuttered aluminium extruded powder coatedopenabledoorofoverallsize0.90mx2.40mwithaluminiumdoorframeof powdercoatedsection101.60x44.75mm,3.18mmthickandshuttercomprisingof powder coated section having bottom andlock rail of size 150 mm x 44.5mm x 3.00 mm thick top rails 47.62x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, with wood boxing to all aluminium tubuler section 3.00mmthickandforshutterplain glass panes 5 mm thick for top panels and 12mmthickbothsidelaminatedphenol bonded particle board panels for bottom panels etc. , i.s.i. mark , heavy duty, hydraulic floor springof150kilogramcapacity,having heavy duty concealed lock, necessary beading,glazingclips,pvcgaskets,250mm length tower bolts, 150mm diam. pad handle, etc. as per detaileddesignanddrawingor as directed byengineer in charge including all materials,labours, andequipment etc.complete(as directed by engineer-in-charge) 4 providing and fixing in position gypsum board false ceiling with 12.5 mm thick gypsum boards, screwed/fixed to the under structure of suspended g.i. grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. the gypsum board should be fixed to galvanized iron grid with necessary screws. the boards should be taped and filled from underside to give smooth, seamless ceiling. the rate should include necessary additional ceiling sections and intermediate channels. additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete(as directed by engineer-in-charge) 5 providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth of approved make, etc complete. 6 providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. 7 providing and fixing rollar blinds ami make or approved make & shade of 38mm round aluminiumchannelwithblackoutfabric&teltingwithchain(ball)systemwithall necessaryfixturesandfittingetc.complete.(sampletobefinalby engineer-in-charge prior execution of work) 8 providingand fixing 1.5 mm thick polyvenyl venyl chlorideflooring includingleveling thebasewithwhitecementincludingpastingwithappropriatematerialcleaningthe surface etc. complete 9 executive table @ 2250lx2100dx750ht including low height credestal @ 1200lx450dx650htproviding&fixingoftable @2250lx2100dx750httop& gable end to be made ofmembrane finish with soft water fall edges & curved panel &decoratedanodizedsectionmodestypaneltobemadeof18mmthick prelaminated particle board with pvc edge band. including credestal @ 1200l x 450d x 650h:- to be made out of membrane finish ( 2 openable shutter & 3 drawerpedestal in between ) as per drawing. 10 free standing table @ 1500lx600dx750htprovidingandfixingtableofsize1500x600x750mm.top:madefrom25mm prelaminatedparticleboard. alledgesarecoveredby2mm.thk.pvcedgebands glued by hot melt glue applied by auto edge banding machine.legs : c shape made from crca sheet with powder coat finish. modesty panel : made from 18mm both side prelaminated particle boards.all edges are covered by 0.8mm pvc edge bands glued by hot melt glue applied by auto edge banding machine.keyboard tray(withoutmousetray):- metalpowdercoated-blackcolor,cpu trolley:- metalpowdercoated-blackcolor,3drawerpedestalunit having overall size 392l x 450d x 680ht. mm. with central lock and key. drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. 11 free standing table @ 1350lx600dx750htprovidingandfixingtableofsize1350x600x750mm.top:madefrom25mm prelaminatedparticleboard. alledgesarecoveredby2mm.thk.pvcedgebands glued by hot melt glue applied by auto edge banding machine.legs : c shape made from crca sheet with powder coat finish. modesty panel : made from 18mm both side prelaminated particle boards.all edges are covered by 0.8mm pvc edge bands glued by hot melt glue applied by auto edge banding machine.keyboard tray(withoutmousetray):- metalpowdercoated-blackcolor,cpu trolley:- metalpowdercoated-blackcolor,3drawerpedestalunit having overall size 392l x 450d x 680ht. mm. with central lock and key. drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, 12 free standing table @ 1200lx600dx750htprovidingandfixingtableofsize1200x600x750mm.top:madefrom25mm prelaminatedparticleboard. alledgesarecoveredby2mm.thk.pvcedgebands glued by hot melt glue applied by auto edge banding machine.legs : c shape made from crca sheet with powder coat finish. modesty panel : made from 18mm both side prelaminated particle boards.all edges are covered by 0.8mm pvc edge bands glued by hot melt glue applied by auto edge banding machine.keyboard tray(withoutmousetray):- metalpowdercoated-blackcolor,cpu trolley:- metalpowdercoated-blackcolor,3drawerpedestalunit having overall size 392l x 450d x 680ht. mm. with central lock and key. drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particleboard, 13 conference table @ 3600lx1400dx750htproviding&fixingofmaintable@3600lx1400dx750ht-madeupof18+18mm thickmdftopwithpvcmembranefinishandwaterfalledgeprofile.aluminium anodizied finish beeding of 4mm thich is running all over the table top edge. gable ends is aerofoiled shape with front edges in pvc membrane finish and rest in prelaminated mdf with batton structure. gable ends should be hollow from inside for the provision of passingelectrical and datawiring. ,modesty panel:- to bemade of18 mm thick prelaminated particle board with pvc edge band access flap:- for wire manager 2 nos. 14 providing & arrangemnt of high back, synchronized mechanism with multiple locking, adjustable armrest, gaslift for seat height adjustment, standard 5-prong p/nylon basewith leatherite upholstery 15 providing & arrangemnt of high back, synchronized mechanism with multiple locking, adjustable armrest, gaslift for seat height adjustment, standard 5-prong p/nylon base with leatherite upholstery 16 providing&arrangemntofmidback,normalsyncro mechanism,fixedarmrest, gaslift for seat height adjustment, standard 5-prong/nylon base with leather upholstery 17 public seating chair. - 3 seaterproviding and fixing 3 seater public seating chair made of complete metal with legs in crome finish and seates in silver powder coating finish. 18 tea table 900mm x 750mm x 450mm for m.s. ante chamberprovidingandfixingofteatable900mmx750mmx450mmwith12mmthick coloureitchedtemperedglasswithbevelleddrawingmadeout of18mmthick waterproofingply.theouterlacestobefinishedwithhighquality4mmthik veneer or 1 mm thik mica etc. 19 kitchen trolleyprovidingandfixingstainlesssteelkitchentrolleyofoverall26heightand22 depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 x 20 x 22 on both sides of trolley of 12 or above size, panel having 40kilogramload bearing capacity of trolley made out of 20 mm puccoatedplywoodandcolourcombinationasdirectedbye-i-c.innersideofpanel covered by white mica ,100 mm s.s. decorative handle.(the width and height of individual compartments shall be kept as directed by engineer-in-charge) 20 providing andfixing 450mm x550mm size superiortype belgium mirrorwith16mm dia. nickel plated towel rod etc. complete. 21 providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm size as per detaileddrawing including vertical bothside polished kadappah stone 25 to 30 mm thick supports with kadappahtop 35 to 40 mm thick and polishedgranite16to20mm topwithsidestripsofgraniteatfrontandbothsidesof platform raised with two verticalgranitesupports15cmheightandtopgraniteof 75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (platform top size 5.00 m x 0.60 m and height is 0.75 m) 22 providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to605mm x590mm to605mm of8to10mm thicknessandconfirmingtois. 15622-2006(groupbla)ofapprovedmake,shadeandpatternforflooringinrequired positionlaidonabedof 1:4 cement mortar including neat cement float, filling joints,curingandclearing etc. complete. 23 providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming tocorrespondingi.s.fordadoandskirtinginrequiredpositionwith readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 24 providing projector - resolutation- xga, white brightness-3300ansi lumens,colour brightness-3300ansi lumens,contrast ratio- 15000:1,lamp life - 6000 hour,weight- aprox 2.5 kg, up to 3x briter colourincluding proector screen-6*4 with stand, with 15 m. hdmi cable and instalationcomplete 25 electrification work 26 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 27 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 28 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 29 supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 30 supplying and erecting mains with 1x1.5 sq.mm frlshcopperpvc insulated wire (earthing) laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 31 point wiring for light/bell/exhaust fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 32 point wiring for independent plug in pvc trunking (casing-capping) with 1.5 sq.mm(2+1e) frlsh grade copper wire, modular type switch,earthing and required accessories as per specification no: wg-pw/sw 33 wiring for plug on board withswitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no: wg-pw/cw 34 supplying and erectingmodular type switch 16 / 20 awith indicator,duly erected on provided plate and box with wiring connections complete. 35 supplying and erectingmodular type 3 pin 6 / 16amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 36 supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 37 supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, t8 led tube light (excluding tube light). 38 supplying and erectingled square / circular max. 14 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 39 supplying and erectingenergy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg-fn/cf 40 supplying and erecting fan hook of 10 mm. m.s. round bar grouted in rcc slab with making the site as original. 41 supplying, erecting & marking spmcb 6a to 32a, c-serieswith rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 42 supplying&erectingtriplepoleand neutral distribution board (tpndb), sp/tp mcbs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb 43 providing & erecting 3 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb 44 supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 20a, 2 pin plug & earth socket and 20a, 3 pin plugtop with 20a/30a single pole mcb having rated short - circuit breaking capacity (icn) 10ka complete erected on angle iron/ gi frame. 45 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 46 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. ea-ep 47 supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessarycopperclampsfixed on wall painted with bituminous paint with joints required. as per specification no. ea-ep. 48 supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 5.0 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap-ac/wac 49 supplying and erecting led panel light(600mm x 600mm) max. 30 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : metal lamp
  • Street Lighting Material Tenders ,
  • Metal Halide Light Tenders ,
  • Led Tube Light Tenders ,
  • Sodium Bulb Scrap Tenders ,
  • Sodium Vapour Light Repair Tenders ,
  • Floodlight Luminaires Tenders ,
  • Torches Tenders ,
  • Sodium Tube Light Tenders ,
  • Lamp Filament Tenders ,
  • Magnifying Lamp Tenders

Get metal lamp Tender Alert...

012776

Related Searched Keywords : metal lamp

  • False Flooring Tenders From Maharashtra
  • Stone Cladding Tenders From Delhi
  • Check Dam Tenders From West-Bengal
  • Road Under Bridge Tenders From -Tamil-Nadu
  • Bridges Tenders From Andhra-Pradesh
  • Acoustic Work Tenders From Gujarat
  • Drilling Tenders From Karnataka
  • Foot Over Bridge Reapir Tenders From Uttar-Pradesh
  • Fencing Work Tenders From Rajasthan
  • Earth Works Tenders From Madhya-Pradesh

Read More


Tender Document

756057

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Earth Excavation Tenders
  • Slab Flooring Tenders
  • Site Leveling Tenders
  • Vinayl Flooring Tenders
  • Desalting Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App