Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Pcc Drain
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of pcc-drain Tenders

List of latest pcc-drain Tenders in Indian Tenders. Click on any pcc-drain Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for pcc-drain Tenders.

Advance Search
  • All-Tenders (48)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Construction
image image
State Government
TRN :49051794 |  10 May, 2025
Tender Value : 81.64 Lacs
 Madhepura - Bihar
Tender for construction of pcc road from vishnudev yadavs house to railway crossing and rcc drain in the middle.
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
3 Security Services
image image
Central Government/Public Sector
TRN :49054152 |  20 May, 2025
Tender Value : 77.92 Lacs
 Abohar - Punjab
Tender for tender for special repair to building no p-137 at mil stn abohar; 1 demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise complete all as specified and directed by engr-in-charge. 2 material & labour for 75mm thick pcc 1:3:6, type c1, using 20mm graded stone aggregate as in hard standing ,plinth protection/path etc,laid in suitable panels n.exc 3.00 m length finished even and smooth without using extra cement with contraction(dummy)joints 65mm deepx10mm wide joints filledwithbituminous sealing compound of grade ‘a’/bitumen mastic filler/sealant complete all as specified and directed by engr-in-charge. 3 dismantling brick tiles in floor or in roofs laid dry and pointed in any cement mortar complete all as specified and directed. 4 demolition of mud in roofs any thickness incl plastering and leeping 5 m & l for 40mm thick cement concrete type b0 1:2:4, (using 12.5mm graded stone aggregate) as in, surface finished even and smooth without using extra cement 6 m & l 10mm thick rendering in cement mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by engr-in-charge. 7 m&l for preparation of roof top surfaces,providing and applying uv stable single component smart care damp proof ultra is a fiber reinforced elastomeric liquied appplied water proofing membrane formulated with pu hybrid polymers and reinforcing acrylics fibres and having sri of 106 on top of concrete roof surface in three coats including self primer at ratio pf dampproof and water 3:1 and coverage @ 1 ltr/10 sqm with a thickness of 650 micron. note : (i) 6 hrs interval between two coats will be maintained. (ii)the treatment shall be carried out by authorised applicator approved by ge as per the manufacturer(iii)payment will be made after providing warrnty certificate from the company. 8 m&l 40mm thick brick tiles laid/beded including screed bed 15mm thick in cement mortar (1:6) on existing lime concrete sufaces of roof,joints grouted flush in cement mortar (1:3) mixed with liquid wpc @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of mes sch part-i (2009) complete all as specified and directed by engr-in-charge. 9 m&l 40mm thick brick tiles( old serviceable tiles obtained from demolition/desmantled item shall be reused) laid/beded including screed bed 15mm thick in cement mortar (1:6) on existing lime concrete sufaces of roof,joints grouted flush in cement mortar (1:3) mixed with liquid wpc @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of mes sch part-i (2009) complete all as specified and directed by engr-in-charge. 10 dismantlingof reinforced cement concrete by chiseling (without affecting other portion) of any description and in any position as in roofs, floors (other than ground floor), beams, landing, chajjas and similar suspended work. 11 m&l reinforced cement concrete 1:1 1/2:3 (nominal mix) using 20mm graded stone aggregate as in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately). 12 m & l mild steel tmt bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with ms wire (annealed) not less than 0.90mm dia all as in column, beam etc . 13 m&l for form work to soffits of suspended slabs such as roof slabs,floor slabs,landings and similar work not exc.200 mm thick(horizontal or sloping) rough finish surface of concrete flat all as specified and directed. 14 m&l for precast reinforced cement concrete (1:2:4) type b1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole set in cm (1:6).note :- cost of form work is deemed to be inclusive of unit rate quoted by the contractor & reinforcementshall be measured & paid separately.) 15 taking down chowkatsor frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified. 16 taking down chowkatswith shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) 17 taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and refixing in same opening after necessary easing, adjustments, minor repairs, oiling, adjustment with cutting or fixing plain fillets/planks made from second class hard wood etc to remove gap between floor and shutter complete all as specified and as directed by engineer-in- charge. 18 taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm eachcomplete all as specified and as directed by engineer-in- charge. 19 s&f factory made single extruded wpc (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 45 x 70 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed ss screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 n (face) & 1100 n (edge), minimum compressive strength of 58 n/mm2, modules ofelasticity 900 n/mm2and resistance to spread of flame of class a category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with ms hold fast/ lugs/ss dash fasteners of required dia and length complete as per direction of engineer-in-charge. (m.s. hold fast/ lugs or ss dash fasteners shall be paid for separately). note :- for wpc solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made all as specified and directed . 20 providing and fixing factory made single extruded wpc (wood polymer composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 n (face) & 900 n (edge), minimum compressive strength 50 n/mm2, modulus of elasticity 850 n/mm2 and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant. wpc to be laminated with pvc foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk s.s screws, all as per direction of engineer- in- charge including supply and fixing following items : (a) stainless steel (304 grade) finished butt hinges 100mm - 4 nos. per leaf (b) stainless steel (304 grade) finished square tower bolt 150 mm long - 2nos per leaf (c) stainless steel (304 grade) finished handles 150 mm - 2 nos. per leaf 21 supply and fixingfactory made pressed steel frames of size 125 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , includingbutt hinges suitable nos as directed for each leaf, complete all as specified and as directed by engineer-in- charge. 22 supply and fixingfactory made pressed steel frames of size 105 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , including butt hinges suitable nos as directed for each leaf, complete all as specified and as directed by engineer-in- charge. 23 m&l cement concrete 1:3:6 type c-1 using 20mm graded stone aggregate for filling of pressed steel frame and hold fast blocks etc complete all as specified and directed by engineer - in - charge. 24 s & f factory made plain framed, panelled shutter iind class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm b.w.p. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per is : 1003 (part i), kiln seasoned and chemically pressure treated complete all as specified and directed by engineer - in - charge. 25 s & f factory made 35mm thick iind class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in ssr part – i, section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by engineer - in - charge. 26 s & f100 mm aluminium alloy anodised butt hinges, and fixed with steel scerws for frp doors/pvc door, type b-21complete all as specified and directed by engineer - in - charge. 27 s & f in repair 100 mm mild steel butt hinges, and fixed with steel scerws for wooden doors, complete all as specified and directed by engineer - in - charge.note :- rate deemed including necessary welding etc) 28 s & f tower bolt 200 mm of aluminum complete all as specified and directed by engineer - in - charge. 29 s & f in repair tower bolt 200 mm of aluminum complete all as specified and directed by engineer - in - charge. 30 s & f door handle d type 150 mm of aluminum complete all as specified and directed by engineer - in - charge. 31 s & f in repair door handle d type 150 mm of aluminum complete all as specified and directed by engineer - in - charge. 32 s & f aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed. 33 s & f in replacement aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed. 34 s&f floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. 35 s&f in repairs floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. 36 s & f mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified. 37 s & f in repairs mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified. 38 s& fstainless steel curtain rod 25 mm dia , including fancy type brackets and pair of decorated end knobs (finials), stop roller etc.as per site requirement, fixed to wall with fixing accessories,including taking down old existing curtain rods any description complete all as specified and directed by engr-in-charge. 39 s&f factory made box type steel window with side hung shuters both glazed and gauged, shutter frame 60x25mm erw hollow p section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx70mmx1.60mm thick including fixing glazed portion, iron grills 8mm suare ms barhinges with steel handle and fitting, lugs etc., including one shop coat of primer complete all as specified.(drg no btd889 sheet 1/4 ).note :- (i) wire mesh and glass shall be measured and paid separately under relevent items of sch/boq.(ii)measurement for payment shall be the opening area of the window between inner edges of wall. 40 s&f factory made box type steel window with side hung glazedshutter, frame 60x25mm erw hollow p section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx70mmx1.60mm thick including fixing glazed portion, iron grills 8mm suare ms barhinges with steel handle and fitting, lugs etc., including one shop coat of primer complete all as specified.note :- (i)wire mesh and glass shall be measured and paid separately under relevent items of sch/boq.(ii)measurement for payment shall be the opening area of the window between inner edges of wall. 41 s&f stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as specified. 42 s & f in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as specified. 43 s & f 4 mm thick sheet glass ordinary quality and glazing within square not exceeding 0.50 sqm including aluminium cleat/rubber beading in each pane complete all as specified and directed by engineer - in - charge. 44 supply & fixing aluminium anodisedframes/chowkhats,shutter and like made out of aluminium sectionpowder coated(minimum thickness of powder coating not less than 50 micron) for window, ventilators and aluminium partition with one or more rebates or without rebate including joining cleat for fixing etc., the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawal plug and screw or with fixing clip or with expansion hold plate fasteners. aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required complete all as specified and as directed by engineer-in-charge.. 45 s & f figured glass 4 mm thick pin head type and glazing withnot exceeding 0.50 sqmincluding aluminium cleat/rubber beading in each pan complete all as specified and directed by engineer - in - charge. 46 material and labour for machine cut 16 to 18 mm thick, kota stone slab (size of slab not less than 500x550mm for flooring and in single piece for treads of staircase), laid over and including 20 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) andpolishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by engineer-in-charge. 47 material and labour for machine cut 16-18mm thick, kota stone slab as in skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangularcomplete all as specified and as directed by engineer-in-charge. 48 taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. 49 m & lfor rendering 15mm thik on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement. 50 m & lfor rendering 15mm thick on fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement. 51 m&l rendering10 mm thick in cement mortar 1:3 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement. 52 m&l integal water proofing compound 53 preparation of new plastered surfaces/existing platered surfaces and applyingwall care putty in internal/external walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony/ceilings etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior/exterior painting complete all as specified and directed.note : (i) the prepared surface after wall putty, the contractor will inform to the ge as well as to the engineer-in-charge for site inspection before applying further external finishes. please note that the further external finishes work will start only after approval of the prepared surface from the ge as well as to the engineer-in-charge through site order. 54 preparation of surfaces and applying 02 coats of interior emulsion paint (light shade) @ 12 sq.m/litre/2 coats by using spray gun to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. 55 preparation of surfaces and applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats by by using spray gun to ceiling surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. 56 preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade)@ 5 sq.m/litre/2 coats by using spray gun to external walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. 57 preparation of new/existing plastered surfaces as in ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer-in-charge. 58 preparation of new/existing plastered surfaces as in walls and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer-in-charge. 59 m & l providing two coats of synthetic enamel paint over new steel surfaces and a coat of red oxide primer onincluding preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by engineer -in -charge. 60 m & l providing two coats of synthetic enamel paint over new wooden surface including preparation of surface withprimer all as specified. 61 m&l for preperationof old steel surface and applying two coat of synthetic enamel paint complete all as specified and directed by engineer -in -charge. 62 m&l for preperationof old wooden surface and applying two coat of synthetic enamel paintcomplete all as specified and directed by engineer -in -charge. 63 m&l for shotcreting 25mm thick in rcc columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 kg/cum on m-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc as directed by engineer-in-charge including chipping of unsound /weak concrete material 25 mmaverage thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with dr fixit epoxy zinc primer or equivalent @ 6sqm/ltr at dft of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of engineer-in-charge. 64 m&l hard drawn steel wire fabric not exc 4kg/sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntall as specified & directed by engineer-in-charge. 65 m & l 5mm thick rendering in cement mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cementcomplete all as specified and directed by engineer - in - charge . 66 dismantling structural steel work including doors,gates but excluding framed truss etc. 67 s & f framed work such as grills,cooler stand ,ladder grating and sun shed etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming tofe 410-0 or fe 310-0 all as specified . 68 dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices. 69 s&f glazed ceramic colouredtiles joint free 350x250x7mm/450x350x7mm square or rectanguleras on walls etc set and jointed in neat cement slurry and pointed in whiteor coloured cement to match over and including 10mm thick rendering in cm 1:4 complete all as specified and directed by engr-in-charge. 70 m&l non skid ceramic coloured /printed tiles 7 to 8 mm thick( square / rectangular) area of each tile exc. 0.11 sqm but n. exc, 0.18 sqm in floor and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shadeover and incl 15 mm thick screed bed in cm 1:6 complete all as specified and directed by engr-in-charge. 71 m&l cement concrete type b-0, 1:2:4 using 12.5 mm graded stone aggregate as in floors 25 mm thick for tilesall as specified.& directed by engr -in-charge.. 72 m&l 16-18 mm thick granite (of any type ) work (table rubbed and polished ) in cooking platform and likein cm (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding/moulding of edges. 73 demolitionof cement concrete ( un re-inforced) of any description in ground floor and pavings exc15 cm thickness (below or above gl). 74 material and labour for water proofing treatment to rcc sunken slab and adjoining vertical slab as described following any one method complete as per directions of ge. 75 method 1(a) supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, smart care damp proof 2k, having 100% elongation as per astm d412, resisting 5 bars hydrostatic pressure as per din 1048, reduction to rapid chloride shall be 70 as per din 1048, crack bridging upto 1.2mm as per astm 4548.5 clean all working surface & made free from dirt, grease laitance etc. after inspection for all working area rough surface, cracks & from dirt, grease laitance etc. after inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 cement : 1polymer : 4 sand). making gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 cement : 1 polymer : 4 sand). the coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. the mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(b) bore packing: all the borehole gaps between concrete surface and pvc pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – smart care gp grout having dual shrinkage compensation property. before the bore packing, surface of the pvc pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent. (c) apply12-15mm plaster on slab and vertical surface admixed with smart care vitalia neo @200ml per bag of cement before treatment. 76 method 2(a) supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm dft, having hydrostatic (positive) water pressure resistance (din 1048) is 7. abrasion resistance, cm/km is 0.09 of dr fixit pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. the polyester reinforced coated netof 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer dr fixit pidifin 2k. after removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola onsurrounding wall’s junction and seal the vertical walls. in case of core cutting on the surface, the joint is seal with non-shrink grout.(b) the coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(c) apply12-15mm water proof plaster on slab and vertical surface admixed with dr fixit pidiproof 77 m & l pcc (1:5:10)using 40mm graded burnt bricksaggregate as in foundation filling & mass concrete or as in sunkenfloor complete all as specified & directed by engineer-in-charge 78 dismantling water tanks and removing to store ofexc 500 and nexc 1000 ltr capacity 79 s & f rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in ssr part i of capacity 1000 litres all as specified and directed by engineer - in - charge . 80 s&f in repair 20mm ball brass valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed. 81 s & f in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified . 82 s & f in 25 mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified . 83 s & f in repairs pvc 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of pvc 32mm bore and connection to wc pan complete all as specified. 84 s&f in repair viterous china squating pan orrisa pattern size 580/440mm wash down water closet pan ,white (excluding fixing bolts, flushing cistern and flush pipe) with plastic seat cover. 85 s&f in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe ,anti-syphonage pipe and white closed patern with flat bottom & mild steel cromium plated or aluminium hinging device plasticseat cover complete . 86 s&f repairs vitreous china half stall urinals flat back white minimum with grating and union for discharge pipe ,providing & fixing plugs, bedding urinal against wall in cm 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified. 87 s & f in repairs vitrous china oval wash hand basin white of size 550x400 mm including brackets 300mm long pvc connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etccoloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified. 88 s&f in repair 600mm x 450mm beveled edge mirror of selected quality glass on 6mm thick commercial plywood and fixed wooden plugs with chromium plated brass screw and cup washes fixed in repair. 89 s & f repairs 15 mm bore concealed stop cock cast copper alloy screwed down high pressurewith crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated with long shank and cup (concealled type) 90 s & f in repairs 15mm bore angle cock one waychromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified . 91 s & f in repairs 15 mm bore bib tap fancy type chromium plated with crutch or butterfly handle screwed down ,screwed for iron pipe all as specified. 92 s&f in repairs pillar taps 15mm borefancy type chromium plated cast copper alloywith capstan heads scre-wed down high pressure with or without lettered hot orcold with long screwed shanks and fly nuts screwed for iron pipe . isi marked 93 s&f in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by engr-in-charge. 94 s&fin repair brass chromium plated shower rose 125mm size with swivel joints,any size, incl shower arm fixing to pipe or union complete all as specified and directed by engr-in-charge. 95 s&f in repair pvc connection both side brass unions internal for size 15mm dia and 450mm long all as specified and directed by engineer-in-charge. 96 s&f ewc jet spray complete all as specified and directed. 97 s & f in repairsoap dish approximately size 160 x160x 90 mm and fixed withas chromium plated brass screws complete all as specified and directed by engineer -in -charge. 98 s&f peg set of stainless steel solid body of 125mm to 175 mm having 6 nos hooks fixed with brass chromium plated screws complete in all as specified 99 taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by engr-in-charge. 100 fixing only mild steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified & directed by engineer-in-charge. 101 supply & fixing mild steel tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed complete to wallall as specified & directed by engineer-in-charge. 102 taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store omplete all as specified and directed by engineer -in -charge. 103 supply & fixing of 16mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing omplete all as specified and directed by engineer -in -charge. 104 supply & fixing of 20mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing omplete all as specified and directed by engineer -in -charge. note :-(i) pipes inside the buildings shall be fixed concealed and outside the buildings shall be fixed on the surface along wall with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, as directed by engineer-in-charge.(ii)bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on btd drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. 105 supply & fixing of 25mm outer dia cpvc pipes sdr 11 including all fittings plain/brass threaded cpvc sdr 11 fittings (like elbow, tee, socket, reducer, union, bushing, step over bends, end cap, end plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including cpvc solvent cement for jointing complete all as specified and as directed.note :- (i) pipes inside the buildings shall be fixed concealed and outside thebuildings shall be fixed on the surface along wall with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, as directed by engineer-in-charge.(ii) bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on btd drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. 106 taking up or down steel tubing of 25 to 32 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by engr-in-charge. 107 s & f 40mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by engineer - in - charge. 108 dismantling of cast iron pipes jointed in cement mortar and taking out from trenches walls etc upto 100 mm bore all as specified and directed by engr-in-charge . 109 supply & fixing 110mm bore upvc pipes grade b single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant c complete all as specified and directed by engr-in-charge. 110 supply & fixing 75mm bore upvc pipes grade b single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant complete all as specified and directed by engr-in-charge. 111 supply & fixing upvc junction (double t/socket) grade b equal or unequal suitable for 110mm bore pipe complete all as specified and complete all as specified and directed by engr-in-charge. 112 all as per item no 109 above 113 supply & fixing upvc bends (any radius) grade b suitable for 110mm bore pipe complete all as specified and directed by engr-in-charge. 114 all as per item no 111 above 115 supply & fixing upvc vent cowl grade b suitable for 110mm bore pipe complete all as specified and directed by engr-in-charge. 116 supply & fixing pvc vent cowl grade b suitable for 75 mm bore pipe complete all as specified and directed by engr-in-charge. 117 supply & fixing upvc grade b multi floor trap 110 mm bore and 600mm long with grating including jointing with with pipe joint lubricant complete all as specified and directed by engr-in-charge. 118 supply & fixing upvc grade b multi floor trap 75 mm bore and 600mm long with grating including jointing with with pipe joint lubricant complete all as specified and directed by engr-in-charge. 119 demolition of brick work built in cement mortar including all quoins, arches, pillars etc . 120 m&l for brick work with subclass‘b’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by engineer-in-charge. 121 labour only forbrick work built in cm (1:6) with subclass b bricks, straight or curved on plan exceeding 6m mean radiuswith reusing the old bricks obtained fromitem no 118 . 122 m&l for taking down carefully point wiring complete including fixture and fittings from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc and making good to disturbed area all as specified 123 m&l for point wiring complete with isi marked 1.5 sqmm single core pvc insulated unsheathed cable 1100v grade frls with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories includingpvc rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, ms hooks, ms junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switchs, sockets, fan regulator etc covered with 3 mm thick plastic laminated hylem top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer includingfixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for the following all as specified 124 (a)one light point/fan point/exhaust controlled byone way switch 125 (b)one light point controlled by one two way switch 126 (c)one 5 pin socket out let 5 amps on the same board with other switches 127 (d)one 5 pin, 5a switch socket outlet point on independent board with other switches. 128 all as per item no. 02 here-in-before but with 2.5 sqmm cable for 1no 16 amps socket outlet point on independent board including 2.5 sqmm pvc insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified 129 s&f piano type switch single pole 1 way 5/6 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 130 s&f socket two in one 6/5 pin 5 amps230 volt ac supply complete all as specified and directed by engr-in-charge. 131 s&f piano type switch single pole 1 way 15/16 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 132 s&f piano flush type switch single pole 2 way 15 amps 230 volt ac supply complete all as specified and directed by engr-in-charge. 133 s&f socket two in one 6/5 pin 15/16 amps230 volt ac supply complete all as specified and directed by engr-in-charge. 134 s&f ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / pvc / polycarbonate isolated body complete all as specified and directed by engr-in-charge. 135 s & f stepped type electronic fan regulator flush type on the existingphenolic laminated sheet etc. as reqd complete all as pecified and directed. 136 s&f lamp holder, pvc/polycarbonate type with back plate suitable for batten fittings with led bulb 09 watt complete all as specified 137 supply and fixing led lights fitting 20 w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 138 supply and fixing led light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete. 139 supply and fixing led street light fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete. 140 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amps capacity complete all as specified and directed by engr-in-charge. 141 s&f sheet metal enclosure for vtpn dbs 415 volts 08 way with 200 amps rated bus bar neautral link, earth bar double door with mccb as incomer complete all as specified 142 s&f sheet metal enclosure for vtpn dbs 415 volts 04 way with 200 amps rated bus bar neautral link, earth bar double door with mcb tpn as incomer complete all as specified and directed by engr-in-charge. 143 s&f sheet metal enclosure for dbs spn 230 volts 12 way with 200 amps rated bus bar neautral link, earth bar double door complete all as specified and directed by engr-in-charge. 144 supply and fixing 415v 16 ka 415 volts mccb of cap 100 amps following poles and current carrying capacity in the db complete with connection testing and commissioning. 145 supply and fixing 415v 10ka b curve miniature circuit breaker (mcb) tpn/4p of capacity 40 to 100 amps poles and current carrying capacity in the db complete with connection testing and commissioning. 146 supply and fixing 240v, 10 ka b curve miniature circuit breaker (mcb) of single poles and current carrying capacity 6 to 32 amp, in the mcb db complete with connection testing and commissioning complete all as specified and directed by engr-in-charge. 147 supply and fixing amp rating 240v, 10ka c curve miniature circuit breaker (mcb) of spn 40 to 63 amp and current carrying capacity in the mcb db complete with connection testing and commissioning complete all as specified 148 m&l forsubmain wiring comprising single core , 2 runs of 2.5 sqmm nominal cross sectional areamulti stranded copper conductor cable, pvc insulated unsheathed 1100 volts gradedrawing in and including appropriate dia. in surface/recessed pvc conduit and its fittings completeincluding provision of 1x2.5 sqmm nominal cross sectional areamulti stranded copper conductor cable, pvc insulated unsheathed 1100 volts grade as earthwire and using color code as per is and specified and making good all disturbed work to match the existing complete incl taking down old unsv sub main complete all as specified and directed by engr-in-charge. note :- (i)extra length of cables/ wire required for connection to mcbs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly.(ii) two run of wire, one run of earth wire and conduct shall be measured as one unit. 149 all as per item no 142 abovebut for single core , 2 runs of 4.0 sqmm nominal cross sectional area including provision of 1x4.0 sqmm nominal cross sectional area complete all as specified and directed by engr-in-charge. 150 all as per item no 142 above but for single core , 2 runs of 6.0 sqmm nominal cross sectional area including provision of 1x 6.0 sqmm nominal cross sectional area complete all as specified and directed by engr-in-charge. 151 m&l for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal gl connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washersand earth strip protected by 15 mm dia gi pipe medium grade and connected to main distribution board panel/earthing test point all as shown on electrical plate no.3 of ssr part i and all as specified including testing on completionincluding taking down old unserviceable earthing any type complete all as specified and directed by engr-in-charge. note :-gi wire 4mm dia including test point terminal box include in the quoted rate.
  • View Tender
  • Document
  • Bid Support
4 Rural Development
image image
Local Bodies
TRN :49054292 |  26 May, 2025
Tender Value : 2.96 Crore
 Firozabad - Uttar Pradesh
Tender for tender for construction work of theme park with in municipal corporation firozabad. - art work 2 shree banke bihari temple - the structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 20 feet. minimum width – 15 feet. minimum length – 28 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 3 cow - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 8 feet. minimum length – 12 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 4 krishna jhoola - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 5 feet. minimum length – 10 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 5 sheshnag - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 12 feet. minimum width – 15 feet. minimum length – 30 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 6 morpankh- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 15 feet. minimum width – 2 feet. minimum length – 6 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 7 pot- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 10 feet. minimum width – 10 feet. minimum length – 12 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 8 fluite- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 2 feet. minimum length – 20 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 9 goverdhan parvat.- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 20 feet. minimum width – 6 feet. minimum length – 20 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 10 external lighting work 11 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63mm dia (od- 63 mm andid 51 mm) 12 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90mm dia (od- 90 mm andid 76 mm) 13 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia ((od- 120 mm andid 103 mm) 14 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 15 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a )25 mm 16 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required . 17 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required . 18 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required . a)single pole 19 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required .b)single pole and neutral 20 supplying and fixing following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (rccb) having a sensitivity current 30 ma in the existing mcb db complete with connections,testing and commissioning etc.as required.40a 21 supplying and fixing following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (rccb) having a sensitivity current 30 ma in the existing mcb db complete with connections,testing and commissioning etc.as required.63 a 22 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required . b) 125 a,36ka,fpmccb 23 supplying, instalaltion, testing & commissioning of1.1 grade, 3x1.5sqmm frls pvc insulated flexible copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required. 24 supplying, instalaltion, testing & commissioning1.1 grade, 3x2.5sqmm frls pvc insulated flexible copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required. 25 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx4 sqmm 26 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx6 sqmm 27 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx10 sqmm 28 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx16 sqmm 29 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx25 sqmm 30 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19883.5c x 70 sqmm 31 supply, installation, testing and commissioning of 50 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 32 supply, installation, testing and commissioning of 30 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 33 supply, installation, testing and commissioning of 90 -100 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 34 supply,installation,testing and commissioning of 25-30 watt warm white ledlinear wall washer luminaire cct 3000k ± 250k for illuminate 3d wall painting with aluminium extruded housing. length of the luminaire shall be 1000mm in size.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270vac ,50hz , powerfactor>0.9. fixture shall be suitable to operate at ambient temperature range of-5°cto+50°c and shall be ip65 and ik06 rated. lifetime should be at least l70:50000 burning hours at 50°c. luminaire shall be conforming to bis and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required engineer-in-charge. the branding name shall be embossed on the housing of the fixture. the minimum warranty shall be for 2 years. 35 supply,installation,testing and commissioning of 40-45 watt warm white ledlinear wall washer luminaire cct 3000k ± 250k for illuminate 3d wall painting with aluminium extruded housing. length of the luminaire shall be 1000mm in size.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270vac ,50hz , powerfactor>0.9. fixture shall be suitable to operate at ambient temperature range of-5°cto+50°c and shall be ip65 and ik06 rated. lifetime should be at least l70:50000 burning hours at 50°c. luminaire shall be conforming to bis and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required engineer-in-charge. the branding name shall be embossed on the housing of the fixture. the minimum warranty shall be for 2 years. 36 sitcjunction boxes outdoor type supply made of thermoplastic polycaronateboxes mini. size 93 x 93 x 62 mm in black colour. the junction box should be ip 67/69 ( iec 60529 ) thermoplastic pc weatherproof with multi level knockouts on four side for cable entry in different sizes . lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. the box should be uv resistant in accordance with iec 61 439-1, clause no 8.4.4. the joint box should be weatherproof : rainwater proof, temperature resistant, connecting box as per iec 60670-22 and iec 60695 – 2 – 11 : flame – retardant & self-extinguishing. glow wire tested at minimum 750 deg c. the box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable terminals . the junction box with nut bolts complete all as per manufacturer’s instructions.make : cat part :- kf 0202 b of hensel/siemens/ge power/schneider/ l&t/abb. manufacturer should submit test certificate as per above standard. 37 sitcjunction boxes outdoor type supply made of thermoplastic polycaronateboxes mini. size 205 x 255 x 112 mm in black colour. the junction box should be ip 67/69 ( iec 60529 ) thermoplastic pc weatherproof with multi level knockouts on four side for cable entry in different sizes . lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. the box should be uv resistant in accordance with iec 61 439-1, clause no 8.4.4. the joint box should be weatherproof : rainwater proof, temperature resistant, connecting box as per iec 60670-22 and iec 60695 – 2 – 11 : flame – retardant & self-extinguishing. glow wire tested at minimum 750 deg c. the box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable terminals . the junction box with nut bolts complete all as per manufacturer’s instructions.make : cat part :- kf 02525 b of hensel/siemens/ge power/schneider/ l&t/abb. manufacturer should submit test certificate as per above standard. 38 providing and fixing of flexible led strip fixtures suiatable for rated voltage 220 volts, 50 hz supply in white /green/red/warm white color including all accessories like connectors, endcap,holding cap and connector pins but excluding integrated led adoptor etc as required. 39 providing and fixing of integrted led adaptor forflexibleled strip fixtures suiatable for rated voltage 220 volts, 50 hz supply etc as required. 40 horticulture 41 horticulture ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size hdpe bag 42 supply of ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in polybag of size 25 cm as per diraction of officer-in-charge 43 supply of rhapis palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed,full of fresh andhealthy leaves in 25 cm size of earthen pot / plastic pot. as per direction of the officer-in-charge 44 supply of areca palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in hdpe bag as per direction of the officer-in-charge 45 supply of wadelia trilobata,full of leaves in 15 cm size in plastic bag as per direction of the officer-in-charge 46 supply of syngonium (butterfly) variegated with 2-3 suckers healthy foliage in earthen pot/ plastic pot of size 25 cmas per direction of the officer-in-charge 47 supply of iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of earthen pot / plastic pot. as per direction of officer-in-charge 48 providing and fixing furcaria variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm cement pot as per direction of the officer-in-charge. 49 providing and displaying topiary of ficus panda well developed with fresh & healthy foliage with 3 to 4 ball and 60 to 75 cm spread each ball, 135 to150 cm ht., in 35 cm hdpe bags /cement pot as per direction of theofficer-in-charge. 50 providing and displaying cyprus golden conical shape 150 to 165 cm ht., with fresh and healthy golden colour foliage in 35cm cement pot as per direction of the officer-in-charge. 51 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. 52 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 53 providing and displaying cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge. 54 providing and displaying bismarckia palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm cement pot as per direction of the officer-in-charge. 55 providing and fixing fishtail palm ht. 240cm bottom girth 40-50 cm well developed in big hdpe bag 56 civil work 57 earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by engineer-in- charge:all kind of soil 58 construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mix plant at omc, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of engineer-in-charge.with material conforming to grade-i (size range 75 mm to 0.075 mm) having cbr value-30 59 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 60 providing and laying 60 mm thick faciory made cement concrete interlocking paver block of m -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer-in-charge. 61 constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand)cluding 500x450 mm pre-cast r.c.c. horizontal grating with frame complete as per standard design : 19.27.1 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 62 providing and fixing g.i chain link fabric fencing of required width in mesh size 50x50mm including strengthining with 2mmdia wire or nuts,bolts and washer as required 63 steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works 64 cc for flooring provision and laying in position cement concrete of specified grade excluding and cost of centering and shuttering. allwork upto plinth level in cc 1:3:6 (1 cement: 3coarse sand: 6 graded stone aggregate 20 mm nominal size) 65 brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 66 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) 67 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
  • View Tender
  • Document
  • Bid Support
5 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
6 Security Services
image image
Central Government/Public Sector
TRN :49055023 |  12 Jun, 2025
Tender Value : 4.85 Crore
 Bengaluru Urban - Karnataka
Tender for tender for provision of deficient smqs at af stn chimney hills; 2 general summary note: schedule ‘a’ part i to xii are prepriced by mes under ser no. 1 to 12. bidders shall insert their lumpsum amount in the green coloured field under col-6 only. 3 lumpsum price worked out by the contractor for “internal water supply” as listed in schedule ‘a’part–ii 4 lumpsum price worked out by the contractor for “internal electric supply as listed in schedule ‘a’part–iii 5 lumpsum price worked out by the contractor for site clearance and development as listed in schedule ‘a’ part - iv . 6 lumpsum price worked out by the contractor for road / path / culvert as listed in schedule ‘a’ part - v . 7 lumpsum price worked out by the contractor for area drainage as listed in schedule ‘a’ part - vi . 8 lumpsum price worked out by the contractor for sewage disposal as listed in schedule ‘a’ part - vii . 9 lumpsum price worked out by the contractor for “fencing” as listed in schedule ‘a’ part – viii. 10 lumpsum price worked out by the contractor for “protective works” as listed in schedule ‘a’ part – ix. 11 lumpsum price worked out by the contractor for “external water supply” as listed in schedule ‘a’ part – x 12 lumpsum price worked out by the contractor for “external electric supply” as listed in schedule ‘a’ part – xi 13 lumpsum price worked out by the contractor for “hot water supply” as listed in schedule ‘a’ part – xii 14 schedule a part - idesign and construction of married accommodation building in 3 storey (ground+2 storey)in framed construction with permanent specifications in rcc of grade as per structural drawings, aac block masonry walls, att, pu based wpt, earthquake resistance as per latest is, green building norms with minimum 3 star griha rating etc complete all as specified and as shown on drawings. 15 design and construction of car and scooter parkingshed in rcc framed construction with permanent specifications in rcc of grade as per structural drawings, aac block masonry walls, pu based wpt, earthquake resistance as per latest is, green building norms with minimum 3 star griha rating etc complete all as specified and as shown on drawings. 16 sch a part - xiii : fittings / fixtures & misc items. internal water supply supply and fix 15mm bore kitchen sink tap, brass chromium plated dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed. 17 supply and fix 3 in 1 chromium plated wall mixer for mixing hot and cold water (for shower) screwed down for iron pipe and fixed complete all as specified and as directed. 18 internal electric supplysupply and fix modular tv socket, one module all as specified and directed by engineer in charge. 19 supply and fix modular telephone socket, rj-11, one module all as specified and directed by engineer in charge. 20 material and labour for telephone wiring with unarmoured solid annealed bare copper industrial cablein concealed of size 0.5 mm, 3 pair with pvc conduit 25 mm diaall as specified and directed by engineer in charge 21 material and labour for tv wiring with unarmoured coaxial cable, rg-11 in concealedwith pvc conduit 25 mm diaall as specified and directed by engineer in charge . 22 material and labour for mild steel box for telephone wiring including blocks, suitable for 30 pair all as specified and directed by engineer in charge. 23 material and labour for earthing complete with galvanised steel pipe electrode of size 40 mm bore, medium grade, 2.5 meter length, burried directly in ground in bore 350 mm dia vertically to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to galvanised earth lead wire 4.0mm dia by meanswith bolts, nuts check nuts and washers protected by gl light grade pipe of size 15 mm dia and connecting up with the db as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, pcc chamber, rcc cover(yellow painted) with handle, watering pipe 20mm dia gi medium grade with funnel and wire mesh, charcoal dust , salt, mild steel earth markerwith earthing result, date all as per plate no.2 of ssr 1991 and as directed by engineer in charge. note:-boring charges are included in the above quoted rates 24 smart meter systemdesign, supply, installation, integration, testing and commissioning of smart meter with prepaid metering facility, ac single phase, two wire, 240 volts, 50 hz , 10 to 60 amps all as per bis 16444:2015 (reaffirmed 2020) with plug in type bi- directional communication module (the plug in module shall be field swappable /replaceable), includingnecessary communication infrastructure suitable for integration with approved communication technology gprs/rf/hybrid (gprs+rf) /any other advance technology as per cea /trai regulations etc.easily adaptable for network interface and integration with advance metering infrastructure (ami) of the project area complete in all respect all as specified and as directedby engineer-in-charge. 25 tv & telesupply and fix pvc conduit 25 mm diaconcealed in wall all as specified and directed by engineer in charge . 26 material and labour for tvwiringwith rg-6 solid copper coaxial audio and video cable for tv antenna, satellite, dvr devices, safe for using in door and out door and drawn through pvc conduit upto required length,all as specified and directed by engineer in charge. 27 material and labour for telephonewiringwith 0.4mm pvc telephone switchboardcablefor telephone , safe for using in door and out door and drawn through pvc conduit upto required length, all as specified and directed by engineer in charge. 28 supply and fix telephone distribution box ,junction box with krone module for multiple connection, all as specified and directed by engineer- in- charge. 29 external water supplymaterial and labour for drilling and tapping gi/ci water mains (in position) for branch connection of 150/100mm including all fittings such as bend, elbows, tees, reducers and unions etc all as directed by engineer in charge. 30 supply and fix brass-metal, 100 mm diaglobe gate valves, with iron wheel head, screwed both ends for iron pipe all as specified and directed by engineer in charge 31 material and labour for construction of brick masonary valve chamber of size 900mm x 900mm x 600mm internal size including necessary earth work excavation, pcc 1:4:8 type d2 for foundation, brick work in cement mortar 1:4, pcc 1:2:4 type b1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40 x 40 x6 mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as directed. 32 material and labour for construction of brick masonary valve chamber of size 600x600x600mm internal size including necessary earth work excavation, pcc 1:4:8 type d2 for foundation, brick work in cement mortar 1:4, pcc 1:2:4 type b1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40 x 40 x6mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as directed. 33 external electric supplymaterial and labour for cutting road / hard standing to depth not exceeding 60 cm and to width not exceeding 45 cm for laying hdpe pipes and making good the disturbed surfacesby 1:3:6 type c1 using 20 mm graded stone aggregate complete all as specified and as directed. 34 supply, install, testing and commissioning of cpri approved lt panel outdoor type of size 1.5x1.2x0.60 mtr suitable size recommended by manufacturercubical floor mounted type (ip-65 degree of protection ) made out of 3 mm thick ms sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 200 amps rating made of aluminium strip (40x5mm) duly drilled holes for connections and mounted on epoxy based post insulatorsfor 3 phase 4 wire 415 volts 50 hz ac supply ,hibling , cable entry boxes , cable gland incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type c1 with 20 mm graded stone aggregates totally tested as per iec 61439-i with the following accessories. 35 incomingmccb 125 amps 25 ka adjustable type 4 pole -01 no@ as in/comingoutgoing(i) mccb 63 amps 25 ka adjustable type 4 pole -03 nos@ as out/going (working-02 , spare-01)(ii) mcb 32 ampstpnamps adjustable type as per - 03 nos@ as out /going(working-02 , spare-01)(iii)multifunctional digital type timer switch230v 50 hz, single phase40amps cap with bay pass system including power cotactor suitable 40 amp mcb 40amps toggle switch cut out of40amps. (iv) powercontactor for rex timer switch 4 pole 40 amps -01 no(v)multifunctional digital type adwancedthree phase meter volt/amp/kva/kw/ +/- 1.0% rated current, auto and manual scrooling,site selectable ct/pt ratios 80/5 etc.housing in ms sheet 1.6 mm thick duly painted with enameled paint over a coat of primer complete in all respect all as directed & specified(vi) phase indicators led type set of 3 - r,y,b -o1 setnote :- foundationfor fixing of lt/feeder pillerboard in ground floor pcc (1:4:8) type b-1 using 20mm graded stone aggregate, measured and paid separately 36 supply and fix smc loop in loop out pvc water proofjunction box of internal size 200 x 140 x 95 mmincluding mcb 6 amps,b class ,connector necessary ms clamps, nuts & bolts with washers etc required at site all as specified and as directed. 37 material and labour for pvc insulated, pvc round sheathed multicore industrial cable of size 3 core,1.5 sqmmfor voltage grade upto 1100 v, as per is 694 all as specified and directed by engineer in charge. 38 returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. note:- excavated soil shall be riddled by using sieve to separate composite particles etc as per is 1255 1983 and refilling in trenches as in cable cushioning. 39 supply and fix gi bracket made out of light grade pipe of size 40 mm dia 1.2 mtr long bent to shape including ms clamp of suitable size nut bolt washer for fixed along the wall/pcc pole with ms clamp etc complete all as specified and as directed. 40 supply and fix mccb 3 pole, 415 v, adjustable type, 125 amps with breaking capacity 25 ka, at existing lt panel and making good connectionwith nut bolts and washers and wire connections etc. to be fixed in theexisting tr panel complete all as specified and as directed. 41 m & l for earthing complete with gi earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m belownormal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 25x4mm gi stripby means of bolts, nuts, check nuts and washers of galvanized iron upto test pointand protected by gi pipe light grade 40 mm bore up to 7.5 mtr connected to a main switch board or main control board and gi pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast rcc 1:2:4, type b-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 kg/sqm in lieu of ci cover, pcc 1:3:6 type c2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in electrical plate no3 of mes schedule part – i of 2009.
  • View Tender
  • Document
  • Bid Support
7 Construction
image image
State Government
TRN :49055031 |  16 May, 2025
Tender Value : 24.07 Lacs
 Bilaspur - Himachal Pradesh
Tender for construction of link road to village nain gujjran km. 0/00 to 2/500. (sh;- periodical maintenance by bituminous concrete between km. 0/00 to 1/700 & c/o pcc u-shape drain at km. 0/060 to 0/320).
  • View Tender
  • Document
  • Bid Support
8 Security Services
image image
Central Government/Public Sector
TRN :49055122 |  29 May, 2025
Tender Value : 40.00 Lacs
 Palam - Delhi
Tender for comprehensive maintenance and certain misc b/r works in tech area at af stn palam under ge (af) palam, delhi cantt - 10; 1.00 taking down cement plaster on brick, stone or concrete surfaces of walls etc incl racking out joints hacking for key scrubbing down with water etc and removing the debris from site to out site mod land complete all as specified and directed by engr-in-charge . 2.00 m&l for 10mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on internal walls, finished the surface even and smooth without using extra cement as on wall as whole or in patch etc complete all as specified and as directed. make- birla (hil) or its equilent. 3.00 m&l for 15mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on external walls, finished the surface even and fair without using extra cement by using dr. fixit (wpc) @ 3% of wt of cement content complete all as specified and as directed. note:- water proofing compound shall be measured and paid seprately. 4.00 m&l for 5mm thick cement plater of ready mix mortar of approved make as on ceiling & plastering to be finished even & smooth without using extra cement complete all as specified and as directed. make- birla (hil) or its equilent. 5.00 supply only integral water proofing compound complete all as specified and as directed. 6.00 m&l for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkalic resistent primer complete all as specified and as directed 7.00 m&l for applying two coats of 100% premium acrylic emulsion paint having voc less than 50 gm/ltr and uv resistance as per is 15489-2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.9 litre /10 sqm over new surfaces complete all as specified and as directed. 8.00 m&l for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkalic resistent primer complete all as specified and as directed. 9.00 m&l for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed. note:- payment for providing grooves shall be measured and paid separately. 10.00 m&l for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications complete all as specified and as directed. 11.00 demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) and removing the debris from site to out site mod land complete all as specified and as directed. 12.00 m & l for 75mm thick cement concrete (1:3:6) type c2 (using 40mm graded stone aggregate) as in plinth protection, finished even and smooth without using extra cement, including making joints 12 mm wide to the full depth of pcc at every 3 metres and at every change of direction and filling the same with & including bitumen 85/25 and sand in the proportion of (1:3 ) by weight complete all as specified and as directed. 13.00 m&l for 75mm thick pcc (1:3:6) type c2 (using 40mm graded stone aggregate) as in path and paving, finished even and smooth without using extra cement complete all as specified and as directed. 14.00 m&l for 25 mm thick pcc (1:2:4) type b1 (using 20mm graded stone aggregate) as in floor, finished even and smooth with using extra cement complete all as specified and as directed. 15.00 m&l for plain cement concrete (1:3:6) type c1 (using 20 mm graded stone aggregate) as in surface channel/drain complete all as specified and as directed. 16.00 extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed. 17.00 supply and fixing in repairs, sfrc drain cover any size, 75mm thick laid over existing drain complete all as specified and as directed by engr-in-charge. notes: - (i) make of sfrc manhole/drain cover and frame : (a) m/s ps concrete.(b) m/s kk manhole.(c) or equivalent as approved by ge. (ii) contractor will provide manufacturer test certificate of sfrc cover . 18.00 dismantling wall and ceiling boards ( fibre, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness, including fillets complete all as specified and as directed. 19.00 m & l for provding false ceiling of 12mm thick fine fissure board sharped finished mineral fiber accountic false ceiling tiles with back of the duly sanded and finshed with a coat of protective paint and front duly finished false system of size (600x600) mm having noise reduction co-efficient of 0.55 light reflection of 80% thermal conductivity k=0.057 w/wwc and humidity resistance of 95% fixed to true look pvc die kl -24 suspension system (hot dipped aglvanised steel section) of exposed t section consisting of perimeter wall angle of size (24x24) mm of thickness 0.45 of mm c/c universal main runner of t shape with double rotary siticing of size (38x25) mm of lenght 1200mm made from 0.33gs steel of lenght 3.60 mtr to be spced at 600x 600mm size) c/c cro runner t shape wtih double rotary siticing of size (30x24)mm of length 1200mm made 0.25 thick gs sheet spaced @ 600mm c/c (600mm 600mm) size complete all as specified and directed by engineer -in- charge. 20.00 taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. 21.00 taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 sqm but n. exc 4.0sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. 22.00 taking down shutters of any description of size n. exc 1 sqm each complete all as specified and as directed. 23.00 taking down shutters of any description of size exc 1 sqm and n exc 2 sqm each complete all as specified and as directed. 24.00 taking down shutters of any description exc 1 sqm and n exc 2 sqm each and re-fixing in the same opening after necessary repairing viz shifting of hinges/tower bolt / handle position etc complete all as specified and as directed. note:- cost of screws/nails and minor items shall be deemed to be included in the unit quoted rates. 25.00 s&f anodised aluminium powder coated frame for door, windows, ventilators, partition wall with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed 26.00 s&f anodised aluminium powder coated door shutter, aluminium section wt 0.55 kg/m including neccesary joining cleats, glazing clips, rubber neoprene packing, aluminium handle 2 nos in each door, hinges, anodised aluminium snap beading screw etc. complete all as specified and as directed. 27.00 s&f anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised, handle 2 nos in each window, aluminium fittings such as peg stays150mm long (1 no.), hinges type b-21100mm long (2 no.), suitable handle (1no.) complete all as specified and as directed. 28.00 s&f aluminium anodised with powder coating (minimum thickness of powder coating 50 micron) grill of design and parttern as approved by ge including aluminium beading complete all as specified and as directed. 29.00 s&f 5.50mm thick tinted, sheet glass of selected quality fixed to aluminium frame work complete all as specified and as directed. 30.00 m&l for 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & fixed with screws to timber/aluminium frame complete all as specified and as directed 31.00 s & f door closer hydraulically regulated designation no 3 universal type suitable for door shutter of 851 to 1000 mm in width of aluminum body (die cast) weight between 61 to 80 kg complete all as specified and as directed. 32.00 m&l double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty complete all as specified and as directed. 33.00 s & f mild steel mortic lock vertical type size 100mm 4 levers complete all as specified and as directed. 34.00 s&f aluminium tower bolt of extruded section, 150mm length of bolt and fixed with screws complete all as specified and as directed. 35.00 s&f aluminium door stopper double legged with rubber shoe 75mm long fixed to door shutters complete all as specified and as directed. 36.00 m & l 2nd class hard wood plain, solid, straight chowkhats, and frame wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. 37.00 s&f for 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and as directed. 38.00 s&f for factory made single extruded wpc (wood polymer composit) solid door/window and other frames/chowkhat of size 50x100 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives(maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed ss screws having minimum frame density of 750 kg/cum screw withdrawl strength of 2200 n(face) & 1100n(edge) minimum compressive strength of 58 n/sqmm modules of ealsticity 900 n/sqmm and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with ms hold fast/ lugs/ss dash fasteners of required dia and length complete as per direction of enger-in-charge. make- m/s rajshree plastiwood ltd or its equivalent as per list of make. 39.00 s&f for factory made single extruded wpc (wood polymer composit) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of k value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives(maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed ss screws having minimum frame density of 650 kg/cum screw withdrawl strength of 1800 n(face) & 900n(edge) minimum compressive strength of 50 n/sqmm modules of ealsticity 850 n/sqmm and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant. wpc to be laminated with pvc foil of minimum 14 microns thick of approved design pasted with hotmelt adhesiv on both faces of shutter and fixing with stailess steel butt hinges of required size with necessary full body threaded star headed counter sunk ss screws all as direction of enger-in-charge. make:- m/s rajshree plastiwood ltd or its equivalent as per list of makes. 40.00 dismantling of floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles and rubbish off the premises complete all as specified and as directed. 41.00 m&l for vitrified ceramic tiles 8-10 mm thick, 1st quilaty (square/rectuangular) polished, double charge shade, area of each tiles exceeding 0.36 sqm but not exc. 0.42 sqm, as in floors etc. set and jointed with neat cement slurry and pointed in white or coloured cement to match with and including over15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. 42.00 description all as per srl item no. 39.00 bove but as in skirting over 10mm thick plastering with cm (1:4) complete all as specified and as directed. 43.00 m &l for ceramic coloured/ printed non-skid tiles of size 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.06 sqm but n exc 0.16 sqm laid as in floors, set and jointed with neat cement slurry with and including over 15 mm thick screed bedding layers of cement sand mortar (1:4) and pointed with coloured cement to match with surfaces of tiles complete all as specified and as directed. 44.00 m&l for glazed ceramic coloured tiles (colour & shade as approved) of size (450x350)mm x 7mm thick as in vertical surfaces as in skirting and dado, set and jointed in neat cement slurry with amd including over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed. 45.00 s&f in repair wash hand basin, vitreous china, flat back (550x400)mm size, white including pvc waste coupling 32mm size, pvc waste pipe 32mm bore, pair of brackets of mild steel (35 x 35 x 6)mm size including one mixer cast copper alloy 15mm bore, one brass stop valve 15mm bore and one pvc connection15mm size with ptmt nuts of length 450mm long complete all as specified and as directed by engineer-in-charge. 46.00 supply & fixing in repair vitreous china ewc super constellation including flushing cistern of size (83x37x66)cm with s trap complete all as specified and as directed. 47.00 supply & fixing in repair vitreous china urinal pot white including partition, waste pipe, screw with wall fixing complete all as specified and as directed. 48.00 s&f in repairs two way wall mixer with popup waste system, hot and cold facilites and 450 mm long braidaed hoses chromium plated complete all as specified and as directed . 49.00 s&f in repair health faucet with double lock 1 meter brass plated stainless steel flexible hose and wall hook complete all as specified and as directed. 50.00 s & f in repair copper alloy cp toilet paper holder complete all as specified and as directed. 51.00 m&l for replacement of 100mm ci floor/nahani trap with grating including jointing and breaking/ dismantling any type of floor and making good cement concrete type b-1 (1:2:4) and testing after repairs and taking down existing trap etc complete all as specified and as directed. 52.00 s&f in repair, brass chromium plated tubular towel rail, 20mm dia, d type, 60cm long between flanges complete all as specified and as directed. 53.00 taking up or down 15mm steel tubing and connections in walls, ceilins, floors, etc including cleaning for refixing or removal to store complete all as specified and as directed. 54.00 m&l for gi tubing, 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed. 55.00 m&l for cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good cutting not exc 10 cm girth as in wall complete all as specified and as directed. 56.00 s&f in repair 15mm bore cast copper alloy, cp angle cock, screwed down, high pressure, with crutch or butterfly handles, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. 57.00 s&f in repair pvc connections 15mm size with ptmt nuts of length 450mm and fixed complete all as specified and as directed. 58.00 s&f in repairs pvc connections 15mm size with ptmt nuts of length 600 mm and fixed complete all as specified and as directed. 59.00 s&f in repair cast copper alloy cp soap dish complete all as specified and directed. 60.00 s&f in repair bib taps with wall flange 15mm bore, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. 61.00 s&f in repair pillar cock, foam flow cast copper alloy, chromium plated, fancy type, 15 mm dia, capastan heads, screwed down high pressure complete all as specified and as directed. make:- cat no 8304 of make prayyag or equivalent as per list of makes. 62.00 s&f in repair plastic water closet seat cover, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. 63.00 s&f in repair pvc valveless, syphonic action type, flushing cistern low level, 10 litre capacity , white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. 64.00 s&f in repair 610 mm long pvc waste pipe flexible type 25 mm dia suitable for couplings 32 mm / 40 mm dia complete all as specified and as directed. 65.00 s&f in repair (600 x450) mm fancy type or bevelled edge mirror of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 66.00 s&f in repairs 15 mm bore bib taps standard of ptmt any colour high pressure screwed for iron pipe and fixed complete all as specified and as directed. (minimum weight 90 gms). 67.00 s&f in repairs 15 mm two in one angle valve cast copper alloy, chromium plated with wall flange and fancy type with high pressure screwed down and with cp flange of same make complete all as specified and as directed . 68.00 m&l for 18-20mm thick granite (of jet black ) work (table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. note:- the cost of half round moulding shall be deemed to be included in unit rate. 69.00 dismantalling water tanks and removal from site of capacity exc 250 ltr and not exc 500 ltr complete all as specified and as directed. 70.00 m &l for 500 litres capacity rotational moulded polyethene water storage tank (cylindrical vertical with closed top), white, three layers, hoisted and fixed in position complete all as specified and as directed. 71.00 supply and fixed ball brass valve high pressure with polythene float and fly nut complete to bore of pipe 20mm complete all as specified and as directed. 72.00 demolition of brick work or stone buillder built in cement mortar of any description complete all as specified and as directed. 73.00 m&l for brick work with sub class b works, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete complete all specified and as directed. 74.00 dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. 75.00 s&f mild steel work such as angle iron post, flat iron in fencing including cutting as making doubble swan neck i.e. y shaped including welding with proper overlapping & welding ms plate with angle iron bottom as directed, drilling holes notching for wire etc embedded in concrete fixed vertically conforming to fe 290 grade e-165 complete all as specified and as directed. note:- embedded portion of angle iron post shall be treated with tar of coat of tar black paint and cost of the same shall be deemed to be included in unit rate. 76.00 m&l for preparation of newly steel surfaces of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer of any height complete all as specified and as directed. 77.00 s&f for concertina coil with punched tape of 600 mm dia (when stretched), centre core wire of minimum 2.5 mm dia of mild steel wire conforming to is 280-2006 with galvanised coating of steel concertina coil as per requirements laid down for medium coated wire in is : 4826 hot dipped galvainsed coating of round steel wires. conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 150 rm for 10 rm of work ,minimum weight 13.5 kg for 10 rm of work including dismantling of existing concertina coil complete all as specifed and directed by engr-in-charge. (note:- the actual weight of concertina coil brought by the contractor at site shall be ascertained by boo as ordered by ge). 78.00 s&f for concertina coil with punched tape of 900 mm dia (when stretched), centre core wire of minimum 2.5 mm dia of mild steel wire conforming to is 280-2006 with galvanised coating of steel concertina coil as per requirements laid down for medium coated wire in is : 4826 hot dipped galvainsed coating of round steel wires. conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 180 rm for 10 rm of work ,minimum weight 16.5 kg for 10 rm of work including dismantling of existing concertina coil complete all as specifed and directed by engr-in-charge. (note:- the actual weight of concertina coil brought by the contractor at site shall be ascertained by boo as ordered by ge). 79.00 dismantling of fencing wire, barbed wire any type and description complete all as specified and as directed. 80.00 supply and fixing galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbed of 75mm spacing and straining and fixing to any type of standard rail, straining bolt including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc as directed (each line wire to be measured) complete all as specified and as directed. 81.00 m&l for cuting holes in brick walls exc half brick but n.exc one brick, built in cement mortar for fixing holdfasts in jambs of existing opening and making good complete all as specified and as directed. 82.00 m&l pcc (1:3:6) type c1 (using 20 mm graded stone aggregates) as in hold fast block including necessary form work complete all as specified and as directed. 83.00 s&f mild steel work framed such as grill, gratings, etc with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to fe.290.gde-e-165. complete as specified and as directed. 84.00 dismantling of fencing wire mesh, any type of any description complete as specified and as directed. 85.00 fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and as directed. 86.00 supply only chain link ms galvanised fencing, 4mm dia gi wire mesh size 100mm x 100mm complete as specified and as directed. 87.00 s&f mild steel screw bolts 12 mm dia (machine made) with hexagonal heads at one end and screwed other end to be fitted with washers (02 nos.) and one hexagonal nut, length of bolt exe 5 cm and n exe 10 cm complete as specified and as directed. 88.00 s&f mild steel fabricated round bars 10mm dia as in horizontal bars for chain link fencing incl necessary hooking at ends all as complete as specified and as directed. 89.00 excavation in post hole (or similar holes) each n.exc 0.50 cum getting out returning, filling in and ramming earth around in layers n. exc 25cm watering and removed surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete as specified and as directed. 90.00 supply and fixing in repairs, pre cast cement concrete jallies, 35 mm thick, type b0 1:2:4 (using 12.5 mm graded crushed stone aggregate) including wire fabric set and jointed in cement mortar (1:4) complete as specified and as directed. 91.00 s&f in repair aluminium composit panel (acp) sheet with 1x1.5 aluminium tube over the framed/ beam of gates. acp shall meet under mentioned technical requirements:- (i) coating on front : high quality polymer resin.(ii) core : fr core (fire retardant)(iii) thickness : 4mm(0.5 mm+3.0mm+0.5mm) (iv) weight : 7.50kg/sqm(v) width: 1200mm(vi) length: 1200 to 2400mm(vii) structure: aluminium panel are protective film,clear coating pvdf,primer coating,antirust layer,aluminium skin and polyethylene.(viii) temp resistance : between -50c to +80c(note:- the quoted rate is deemded to be included necessaryy scaffolding required and joint sealing) 92.00 s & f in repair 12mm thick toughened glass fixed with double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty and stainless steel handle purpose made on both side with locking machanism and with necessary stopper etc complete all as specified and as directed. 93.00 demolition and breaking up drain pipe 75/100mm dia ( salt glazed ware, ac or pvc) of any type complete all as specified and as directed. 94.00 s&f 75 mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed. 95.00 s&f 110 mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed. 96.00 s&f in repairs pvc(swr) bends any radius, 75 mm bore complete all as specified and as directed. 97.00 s&f in repairs pvc(swr) bends any radius, 110 mm bore complete all as specified and as directed. 98.00 hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. 99.00 s&f sheet glass 4mm thick ordinary quality and glazing with oil putty or rubeer bedding in square n. exc 0.5 sqm in each pane complete all as specified and as directed. 100.00 s&f in repairs of sink with drainage board, made out of stainless steel 1mm thick, kitchen or laboratory with plugs, washes and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever bracket and connecting union to pipe over all size (915x460)mm with bowl size (410x330x160)mm complete all as specified and as directed. 101.00 s&f in repair brass chromium plated shower rose,125 mm size fixed to 15 mm bore iron pipe complete all as specified and as directed. 102.00 s&f in repair water closet vitreous china squatting pan, orissa pattern size (580x440)mm white with integral foot rests (excluding flushing cistern and flush pipe) and including with p or s trap complete including provison of lime concrete bedding fixed in repair complete all as specified and as directed. 103.00 m&l for gunniting work to rcc work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and s&f welded wire mesh fabric or wire net less than 95 x 95x 3 mm tied to existing reinforcement with nails,adhesive plaster grade for concrete and providing gunniting pressure 2.0/2.5kg/sqm with admixture 1 part of cement and 3.5 part of sand with average thickness 40 mm and making the surface even including 15mm thick plastering in cm 1:4 on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement including necessary form work to be carried out,complete all as specified.(note.- wherever reinforcement required shall be measured and paid seperately) 4. structural steel steel authority of india limited (sail) brand: sail / rashtriya ispat nigam limited (rinl) brand: rinl / tata iron & steel company (tisco, or tata steel) brand: tata / m/sjindal steels and power ltd. brand: jindal 5 factory made paneled/ glazed /gauged door shutters m/s mp wood product indore, m/s jain doors pvt ltd sonipat, goyal industiral corporation new delhi, shri krishna industries, panchkula, 6 factory made flush door shutters m/s green ply industries, m/s centuary ply, m/s dura ply. mysore chip board, archid, swastik ply wood, m/s jain doors pvt ltd 7 pvc door frame/shutters sintex, rajshri plastiwood ltd, m/s dura plast extraction pvt ltd, m/s fenesta, ecocell,accucell 8 frp door frame and shutter selected products co., sintex, rajshri plastiwood ltd, accure polytec pvt ltd ,ecocell, fiberways 9 upvc window/doors fenesta, ncl veka, madhu industries, h2o solutions, yashpoly,accucel, okotech, aseco (m/s ashish industries) 10 iron mongery mowjee, m/s kitch architectural product pvt ltd, rs industries. 11 hydraulic door closer everest, universal, godrej 12 particle board(veneered & unveneered laminated)/ block board kitply, nova pan industries, new delhi, m/s green ply industries ltd, archid ply, bhutan board, dura board mysore chip board ltd 13 plywood for general purposes dura ply, archid ply, bhutan board,archid board, century, durian, mysore chip board ltd 14 decorative laminates archid lam, sunmica, merino, lam, mysore chip board,greelam 15 terrazzo tiles ntc, nitco, eurocon, duracrete 16 glazed ceramic/non skid wall/floor tiles kajaira, johnson, agl, qutone , somany, nitco, orient bell ,vitero, sunhearrt ceramik, varmora 17 vitrified tiles (polished, unpolished & glazed, normal/ anti skid) kajaira, johnson, agl, qutone , somany, nitco, orient bell,vitero,sunhearrt ceramik, varmora 18 hdpe storage water tanks sintex, supreme,plasto,polycon 19 sanitary appliances /fittings(chinaware) hindware,parryware,cera,jaquar, kohler, prayag aproyale,somany 20 water closet seats and cover (solid bakelite) thermostat moulded toilet seat cover parryware, jaquar, prayag somani,commander,cera,neycer 21 pvc flushing cisterns hindware, commander, parryware, cera ,jaquar, johnson pedar, neycer 22 stainless steel kitchen sink with or without draining board, plate rack nirali,cera,diamond,jainco,shakti prayag, (silver shine) m/s bluestar sanitary industries 23 ball valves (horzontal plunger type) dripless faucets india, flowjet , ball valves inida. 24 shower roses chromium plated (swivel type) gem,jaquar, jal 25 bath room fancy fittings jaquar,gem,marc, jalangi 26 bib taps and stop taps (cp),pillar tap, fancy fittings jaquar, parko, gem, marc 27 bathroom cabinets jaquar, cera, commander, parryware .... more in document
  • View Tender
  • Document
  • Bid Support
9 Security Services
image image
Central Government/Public Sector
TRN :49055340 |  31 May, 2025
Tender Value : 49.00 Lacs
 Pune - Maharashtra
Tender for tender for welcome maint to offrs md accn under age br-i of ge (south) pune; 1 m&l for preparation of old decorative surfaces of ceiling including cornices (plastered or un-plastered) by brooming down and scrapping wherever necessary and applying one coat of white wash complete all as specified and directed 2 m&l for preparation of old decorative surfaces of wall including, cornices (plastered or unplastered)of any description, sand papered and dusted and applying one coat of oil bound distemper of any tint complete all as specified and directed. 3 m&l for preparation of old decorative surfaces of wall including, cornices (plastered or unplastered)of any description, sand papered , and dusted including complete removal of existing surface of walland applying two coats of oil bound distemper over and including a coat of 2mm thick wall care putty complete all as specified and directed 4 m&l for preparation of old painted wooden surfaces exc. 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed 5 m&l for preparation of old painted steel surfaces exc. 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed 6 m & l for preparation of surface of any description (plastered and old decorated) over 10 cm width or girth including removing of existing treatment completely and applying two coats of weather proof exterior paint complete all as specified and directed 7 m&l for preparation of old painted surfaces of walls by brooming down or steel wire brushing , scraping down soot, moulds, moss and efflorescent salt etc surface of any description (plastered and old decorated) over 10 cm width or girth and applying one coatof weather proof exterior paint complete all as specified and directed 8 m & l for preparation of surface of any description (plastered and old decorated) over 10 cm width or girth and applying one coat of luster paint complete all as specified and directed 9 m & l for french polishing on surfaces of any description, exceeding 10 cm width or girth over and including a coat of a coat of wood filler including cleaning and preparation of old wooden surfaces complete all as specified and directed 10 m & l for applying two coatsof oil bound distemper on walls over and including a coat ofpriming with chalk whitening including preparation of new plaster surfaces complete all as specified and directed 11 m&l for applying three coats of white washon ceiling and including preparation of new plaster surface complete all as specified and directed 12 m&l for applying two coats of cement base paintover and including a coat of alkali resistant primer on walls including preparation of new plaster surfaces complete all as specified and directed 13 m & l for preparation of brooming down or steel wire brushing, scraping down soot, moulds, moss and efflorescent salt etc and applying one coat of cement base paint over and including a coat ofalkali resistant primer on walls including preparation of oldsurfaces complete all as specified and directed 14 taking down cement plaster from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water complete all as specified and directed. 15 m&l for 15 mm thick plaster in cm 1:3 on concrete surfaces finished even and smooth using sagol finish on ceiling complete all as specified and directed 16 demolition of brickwork masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. 17 m&l for old sizefly ash bricks, straight or curved on plan exc. 6 m mean radiusbuilt in cm 1:6 complete all as specified and directed 18 m&l for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cm 1:4 complete all as specified and directed 19 m&l for rendering 20 mm thick plaster in two layers on stone masonry surfaces or on other than fair faces of brick / pcc block masonry of walls (first layer 10 mm thick in cement mortar 1:6 and second layer 10mm thick in cm 1:6) and finishing the surface even and smooth without using extra cement complete all as specified and directed. 20 m&l for rendering 20 mm thick plaster in two layers on stone masonry surfaces or on other than fair faces of brick / pcc block masonry of walls (first layer 10 mm thick in cement mortar 1:6 and second layer 10mm thick in cm 1:4 mixed with wpc as per manufacturer’s instructions) and finishing the surface even and smooth without using extra cement complete all as specified and directed.note :- wpc shall be measured and paid separately as supply only under respective item of boq. 21 m&l for rendering 15 mm thick on fair faces of brick work / concrete surfaces in cement mortar 1:4mixed with water proofing compound as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified and directed.note :- wpc shall be measured and paid separately as supply only under respective item of boq. 22 m&l for rendering 15 mm thick on fair faces of brick work in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed 23 m&l for pcc 1:3:6 type c-1, (using 20mm graded stone aggregate) of75mm thick, laid in alternate bays as in path and plinth protection including finishing the surfaces even andsmooth using extra cement, complete all as specified and directed 24 s&f in repairs pvc connection 60cm long 15mm dia with 2 nos. pvc nuts repairs complete all as specified and directed. 25 demolition of cement concrete in ground floor and pavings n. exc. 15 cm thickness (below or above gl), complete all as specified and directed. 26 demolition cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. 27 m&l glazed coloured digital printed ceramic tiles of size 600x300x7-8mm thick in vertical surfaces etc set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles with and including 15mm thick backing coat in cm 1:4 including triangular filleting in cm 1:4 on top edges including dismantling of old unserviceable tiles including backing coat of any description and removal of debries & dismantled materials complete all as specified and directed 28 m & lfor water proofing treatment to sunken slab, walls,etc. shall be carried out as specified below and as directed by engineer-in-charge:-(a) dismantling & remove the existing lean concrete completely and clean the sunken portion of toilet / baths / wcs / kitchen thoroughly remove laitance, dirt, dust etc.(b) form angle fillet of size 40 mm x 40 mm along the junction of wall and floor by using polymer modified mortar (“ dr fixit” pidicrete urp” or equivalent).(c) sanitary pipes entering through walls and floor shall be sealed with “dr fixit bathseal tape” and the gaps to be grouted with non-shrink cementitous grout “dr fixit bathseal grout” or equivalent. nahani traps etc to be fitted securely and the gaps around it to be grouted in the same manner.(d) apply one coat of a bitumen-modified polymer coating “dr fixit bathseal plus” or equivalent on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet and applying second coat of the same coating on the angle fillets and allow it to dry completely. contd...... 29 (e) in the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. extend the coating upto150mm above the ffi. above ffi, another cementitious waterproofing waterproof coating “dr fixit pidifin 2 k” or equivalent to be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hoours and allow to dry completely.(f) after 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed m 15 type b0 mixed with integral wpc (liquid) laid to stope 1:60 towards outer face of wall. provide 40 mm od upvc pipe at the lowest point with 300 mm projection beyond the outer face of the wall. then fill up the sunken portion with lean concrete 1:5:10 type e2.(g) after completing plumbing work in the toilet/wc/bath/kitchen, floor, tiling work (floor and dado) to be carried out by using suitable tile adhesives and ready to make tile grouts of approved makes such as dr fixit, fosroc sika, mc buchemie, roff, etc. note: lean concrete 1:5:10 type e-2 shall be measured and paid separately under respective item of boq. 30 m&l for pcc 1:5:10 type e-2 using 40 mm graded brick aggregate as in filling sunken portion, complete all as specified and directed. 31 m&l for 25 mm thick pcc 1:2:4 type b-1 (using 20mm graded stone aggregate) as in leveling course or pcc padding, finished the surfaces fair & even, complete all as specified and directed. 32 m&l for cleaning and removing all scale and dirt, etc, from tanks n. exc. 500 ltrcapacity and from mouths of circulating pipes etc including writing of date of cleaning with synthetic enamel paint complete all as specified and directed. 33 m&l for cleaning and removing all scale and dirt, etc, from tanks exc. 500 ltrs but n. exc. 1000 ltrcapacity and from mouths of circulating pipes etc including writing of date of cleaning with synthetic enamel paint complete all as specified and directed. 34 m&l for cleaning and removing all scale and dirt, etc, from tanks exc. 1000 ltrs but n. exc. 2000 ltrcapacity and from mouths of circulating pipes etc including writing of date of cleaning with synthetic enamel paint complete all as specified and directed. 35 m&l for granite (of any type) work (table rubbed and polished) 18-20mm thick as in steps, jambs, pillars, window- cills,cookingplatforms, as counters of any radiuos and like setting in neat cement slurry including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 20mm thick screed / backing coat in cement mortar (1:4)including dismantling of old unserviceable slab / tiles including screed bed of any description and removal of debries & dismantled materials complete all as specified and directed 36 rounding (half) of edges of granite stone slabs , as in steps, cooking plateform slab and other similar situations complete all as specified and directed. 37 s&f in repair cascade type (coloured) floor mounted single piecewater closet withpp soft close slim seat cover , hinges, dual flush cistern fittings, fixing accessories and accessories set , size 365 x 675 x740 mm, strap -220 mm pipe etcconnected to pipe complete all as specified and directed by engr in charge confirming to cat no. esc-wht-851s220sppsm essco (jaquar)or of equivalent make as specified here-in-after complete all as specified and directed 38 s&f in repairs glass coner assembly cosisting of 5.5 mm thicksheet glassround(9 x 9 ) with satinless steel railing, complete all as specified and directed 39 s&f inrepairs satinless steel robe hook (khuti) with5hook, complete all as specified and directed 40 s&f in repairs sink cock with swinging casted spout with aerator(wall mounted model) conforming to cat no. orb-105347 essco (jaquar) or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 41 s&f cp towel ring round with round flange conforming to cat no acn-1121 bn of jaquar / 9218 of prayag or equivalent cat part from the makes as specified here in after, complete all as specified and directed. 42 s&f in repairs brass chromium plated shower rose 100 dia with 235 mm long arm with or without swivel joints, including fixing to steel pipe or union, complete all as specified and directed 43 s&f in repairs brasscp wall mixer3- in-1 system with provn for both hand shower and overhead shower complete with 115 mm long bend pipe connecting legs and wall flange (without hand & ovwer shower ) conforming to cat no.ste-107281 stellaessco (jaquar) or equivalent cat part from the makes as specified here in after, complete all as specified and directed. 44 s&f in repairs cp 15 mm fancy long body bib taps brasswith wall falnge & aeratorconforming to cat no. sqt- 512kn essco ( jaquar) or equivalent cat part from the makes as specified here in after, complete all as specified and directed. 45 s&f in repairs soap dish cat no. acn-1131n jaquar / ba-259 of prayag or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 46 s&f in repairs cp toilet paper holder conforming to cat no. acn-1151 n of jaquar / ba-38 of prayag or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 47 s&f in repairs cp towel rail 20mm dia and600mm long including brackets conforming to cat no. acn-111n of jaquar/ ba-20 of prayag or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 48 s&f in repairs health faucet cat no. ald-583kn of jaquar/ bea-85 of prayag or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 49 s&f in repairs angular type stop cock with flangeconforming to cat no.apr -101053 essco of (jaquar) or equivalent cat part from the makes as specified here in after, complete all as specified and directed. 50 s&f in repairs cp 2 way bib cock with wall flange conforming to cat no. ste-107041,essco ( jaquar) , cera orequivalent cat part of makes as specified here-in-after, complete all as specified and directed 51 s&f in repairs cp pillartaps swan longneckwith aerator15mm bore fancy type with wall flange conforming to cat no orb -105001n essco ( jaquar) or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 52 s&f in repairs stainless steel towel rack with lower hangers, 600mm long conforming to cat no. can-1181fhs of jaquar or of equivalent cat part of makes as specified here-in-after, complete all as specified and directed 53 taking up or down steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed for following size of pipe :-(a). 15mm bore. 54 (b). 20mm bore. 55 s&f of following dia gi pipe, medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etccomplete all as specified and directed.(a). 15mm bore 56 (b). 20mm bore. 57 re-fixing only following dia gi pipe, medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etccomplete all as specified and directed.(a). 15mm bore 58 (b). 20mm bore. 59 m&l for cutting chases, pinning in, concrete, block /brick or stone walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing and making good, cutting n. exc. 10 cm girth, complete all as specified and directed. 60 s&f pvc (swr) 110mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or fixed to wall including dismantling of old unserviceable breaking up drain pipes pvc or ac set in cm or solvent,complete all as specified and directed.note for item nos. 55 & 56:- rate quoted shall deemed to be inclusive of necessary scaffolding / security measures as the work is to be carried out for elevated height upto 12 mtr height building. 61 s&f pvc (swr) 75mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or fixed to wall including dismantling of old unserviceable breaking up drain pipes pvc or ac set in cm or solvent,complete all as specified and directed. 62 s&f pvc (swr) bends any radius 110 mm bore complete all as specified and directed. 63 s&f pvc (swr) bends any radius 75 mm bore complete all as specified and directed. 64 s&f pvc (swr) vent cowl 110mm bore, complete all as specified & directed. 65 s&f in repairs pvc (swr) branch piece, (double y) equal or unequal of 110 mm bore, complete all as specified and directed 66 s&f in repairs pvc (swr) branch piece, (double y) equal or unequal of 75mm bore, complete all as specified and directed 67 s & f 110mm pvc (swr) wc connector bent type complete all as specified and directed. 68 s&f pvc (swr), 75mm dia outlet floor trap, plain with grating including jointing with solvent cement, fixed to cement concrete type b1 1:2:4, complete all as specified and directed. 69 s&f pvc (swr), 75mm dia outlet multi floor trap, plain with grating including jointing with solvent cement, fixed to cement concrete type b1 1:2:4, complete all as specified and directed. 70 m&l for cutting, screwing & threading of existing 15mm bore steel tubing for alterations or additions (each cut measured) complete all as specified and directed 71 m&l for cutting, screwing & threading of existing 20mm bore steel tubing for alterations or additions (each cut measured) complete all as specified and directed 72 m&l for cutting, screwing & threading of existing 25/32mm bore steel tubing for alterations or additions (each cut measured) complete all as specified and directed 73 taking down chowkhat or frames n. exc. 1.5 sqm each with shutter without taking off shutter from the frame complete all as specified and directed. 74 taking down chowkhat or frames exc. 1.5 sqm but n. exc. 4 sqm each with shutter without taking off shutter from the frame complete all as specified and directed. 75 taking down shutters of any description exc. 1 sqm and not exc. 2 sqm each and remove from site, complete all as specified and directed. 76 s&f in repairs vitreous china, squatting pan, orissa pattern, size 580 x 440 mm white, with integral foot rest, including concrete bedding and pvc flushing cistern 10 ltr capacity including all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed. 77 s & f in repairs, vitreous china wash basin, white, flat back, size 550 x 400 mm with brackets, inc. cutting for & pinning in ends of brackets, including32 mm dia brass cpwastecouplingand32 mmdia low density polyethylene(ldpe) pressure rating 6 kg / cm² as waste pipe complete all as specified and directed 78 s&f in repairs vitreous china wash down water closet pan, pedestal white, including fixing bolts etc including pvc seat cover white with flat bottom including ms, cp or aluminium anodised hinge devices including pvc low level flushing cistern 10 ltr capacity with all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed. 79 s&f in repairs ewc seat cover of any pattern including cover and mild steel chromium plated hinging devices of any colour, complete all as specified and directed. 80 s&f in repairs, stainless steel plate rack of size 36 inch x 30 inch x 10inch, made out of 0.63mm thick stainless steel sheet (grade 304), s s screws and round pipe,fixed to wall with screws complete all as specified and as directed 81 s&f in repairs flexible waste pipe of 32 mm dia suitable for wash hand basins, sink etc of suitable length, complete all as specified and directed 82 s & f in repairs spindles of any size suitable for concealed mixer valves, stop valves, angle cock, fancy taps including knob heads complete all as directed by engineer-in-charge. 83 s & f in repairs kitchen or laboratory sinks made of stainless steel 1mm thick sheet with plugs, washers, and wastes coupling, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, bowl size 560x460mm including coupling etc complete all as directed by engineer-in-charge. 84 s&f in repair high density 40mm bore polyethylene pipes (hdpe) of pressure rating 6 kg/cm2 fixed to wall or in floors with necessary socket, elbow & bendetc complete fixedto wall or in floors etc complete all as specified and directed. 85 s&fin repair pvc low level flushing cistern 10 ltrs capacity with and including all internal fitting, pair of bracket, including inlet / outlet pvc pipe connections etc. complete all as specified and directed 86 m&l for joint free non-skid ceramic coloured tiles 7 to 8 mm thick area of each tiles exceeding 0.11 sqm but not exceeding 0.18 as in floors, set an jointed in neat cement slurry and pointed in white or coloured cement to match including laid over and including 20 mm thick screed bed in cm 1:6 including taking of old existing unserviceable tiles of any type including screed bed and removing of debries & dismantled materials etc. complete all as specified and as directed 87 m&l for coloured vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.16 sqm but not exceeding 0.36 sqm as in flooring, set and jointed in neat cement slurry & pointed in white or coloured cement to match laid over and including 20mm thick screed bed in cm 1:6 with including taking of old existing unserviceable tiles of any type including screed bed and removing of debries & dismantled materials etc. complete all as specified and as directed 88 s&f in repairs 20mm dia aluminium powder coated, fancy type curtain rod medium grade fixed in and including bracket, stops roller etc complete all as specified and directed 89 s&f stainless steelfency type caps / side bulbs etc. suitable for 20mm dia curtain rod pipe complete all as specified and directed. 90 s & f pressed steel frames for doors with one & more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm including ms hold fast - 6 nos. and ms cold rolled 100mm size butt hinges welding to existing ms frame including pcc bed block in 1:2:4 type b1 for hold fast and cement concrete 1:3:6 type c1 (12.5mm graded stone aggregate) for filling in ms hollow frame complete all as specified and directed. 91 s & f pressed steel frames for doors with one & more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm including ms hold fast - 3 nos. and ms cold rolled 100mm size butt hinges welding to existing ms frame including pcc bed block in 1:2:4 type b1 for hold fast and cement concrete 1:3:6 type c1 (12.5mm graded stone aggregate) for filling in ms hollow frame complete all as specified and directed. 92 s&f pvc door frame of size 50mm x 47 mm made out of 5mm plain colour pvc sheet reinforced with ms square tube, suppling & fixing in opening as per specification and drawing. 93 supply and fixing factory made solid pvc shutters,30 mm thick (style) consisting of frame made out of ms tube for top and bottom rails. ms frame shall be covered with heat moulded plain colour pvc c channel having a pvc sheet strips of 20mm width stuck inside with solvent cement for stiles and plain cover pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail; panneling of plain colour pvc sheet to be fitted in the ms frame welded / sealed to the stiles & rail with suitable pvc sheet beading, and joined together with solvent cement, supply and fixing in the frame at site as per specification and drawing. 94 s&f 300 mm long aluminium alloy, anodised , sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy fixed complete all as specified and directed. 95 s&f 200 mm long aluminium, anodised, barrel tower bolts of extruded section isi marked complete all as specified anddirected. 96 s&f 100mm size extruded aluminium anodised alloy handles, fabricated type, isi marked complete all as specified anddirected. 97 s&f pvc (swr) gully trap 125x110mm, setting and jointing with solvent cement, complete all as specified and directed. 98 s&f 100 mm long butt hinge, alum electroplated, heavy weight, cold rolled mild steel and fixed complete all as specified and directed. 99 s&f in repairs 600 x 450mm beveled edge lookingmirror of selected quality glass, mounted on 6 mm thick ac built board or commercial ply board and fixed to wooden plug with chromium plated brass screws and cup washer etc. complete all as specified and as directed 100 s&f aluminium powder coatedthree track sliding window with two or more shutters with & including 4mm thick tinted glass, one shutter of stainless steel wire cloth 0.36 mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing, handle, lock etc using pvc beadingetc using following sections of `jindal aluminum ltd or equivalent in ajit india pvt ltd or crystal bombay, as approved fixing to stone masonry walls with & including ist class teak wood plugs of size 20mmx20mm at an interval of 0.5m around the track including drilling holes etc complete all as specified and directed:(a) frame bottom20620(b) frame top& side 20681(c) shutters top & bottom 20844(d) shutter inter lock 20724(e) handle (side) for 20606 shutters 101 s&f ventiltors / louvers with partially guaged shutter using 5 mm thick x 10 cm wide frostedglass strips andby using of following aluminium powder coated sections conforming to catalogue of jindal or of equivalent make including with rubber beading etc, complete all as directed by engr-in-charge.(a) sp20048(b) glazing clips19352 102 s & f150 mm length floor door stopper of brassbody and tongue, hard drawn steel spring complete all as specified and directed. 103 s&f of 18/19 mm thick block board, grade i quality exterior grade type with decorative face veneer on both faces including lapping of edges fixed with screws to timber frame work as in cb partition and shelf and other works complete including dismantling of old unserviceable boards of any type complete all as specified and directed 104 s&f continuous (piano) hinges, mild steel, bright finish, width of flaps (when open) 30mm, complete all as specified and directed. 105 s&f in replacement 100 mm brass fancy type cupboard handle fixed with nuts, screws and washer of brass polished, complete all as specified and directed. 106 s&f in repairs magnet catches and striking plate, complete all as specified and directed 107 removing building materials etc to a distance exceeding 5 km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed. 108 m&l for gypsum ceiling board,pre-painted, perforated finish, 600x600x8 to 9mm thick in size of approved brand / make, laid over and including grid work of size 595 x 595mm, made out of 0.5mm thick g.i. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle, hung from ceiling by using 2 mm thick g.i. suspension wires spaced at 1200 mm on main runners including making niches for fans & light , complete all as specified and directed 109 all as per item no.103 but repair only to the existing false ceilings of any description complete all as directed by engr-in-charge 110 dismantling of wall / ceiling boards including snap grid of any thickness including cover fillets, complete all as specified and directed. 111 s&f 4 mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beadings in square n. exc 0.5 sqm in each pane, including hacking out old broken glass if any (any thickness, quality & size), complete all as specified and directed. 112 m&l for machine cut cudappah stone slab one side pre-polished, 30-40mm thick as in kitchen platform base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 15 mm thick screed bedding layer in cm 1:4 including dismantling of old unserviceable slab / tiles including screed bed of any description and removal of debries & dismantled materials complete all as specified and directed 113 s&f of 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sideincluding 5mm thick,1st class hw (tw) beading all around on edging andcomplete all as specified and directed by engr-in-charge 114 m&l for 35mm thick iind class hard wood glazed and skeleton shutters, openrebated and prepare to receive glass (with sash bars), guage etc divided into squares with plain, chamfered or rounded, mitered and rebated sash bars any number, size of members of shutters as specifie in clause 8.24(a) of ssr part-i 2009, complete all as specified and directed. 115 m&l for applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description exc. 10 cm width or girth, including preparation of surfaces, complete al as specified and directed. 116 m&l for applying two coats of synthetic enamel paint over acoat of red oxide primer on new steel surfaces exc. 10 cm width or girth, including preparation of surfaces, complete al as specified and directed. 117 m&l for 2nd class hard wood wrought plain fillets square, rectangular or triangular in section clean sawn secured with screws, sectional area exc. 13 sqcm but n. exc. 25 sqcm etc complete including dismantling of timber fillets from cabinet / cupboard frame, complete all as specified and directed 118 s & f in repairs gun metal, globe gate valves(class i), with iron wheel head,screwed both ends for iron pipe, isi marked, all as specified and directed for the following bore dia of pipe:-(a) 15mm bore. 119 (b) 20mm bore. 120 (c) 25mm bore. 121 s&f 25/32mm bore ball valve high pressure of ptmt with epoxy coatedaluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms), complete all as specified and directed. 122 s&f 20mm bore ball valve high pressure of ptmt with epoxy coatedaluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms), complete all as specified and directed. 123 s&f 15mm bore ball valve high pressure of ptmt with epoxy coatedaluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 142 gms), complete all as specified and directed. 124 supply only liquid water proofing compound, complete all as specified and directed. 125 s&f in repair for stainless steel wire cloth 0.36nominal dia of wire and average width of aperture 1.4mm and fixedwith stainless steel staple to wooden / steel frames, complete all as specified and directed
  • View Tender
  • Document
  • Bid Support
10 Security Services
image image
Central Government/Public Sector
TRN :49055382 |  27 May, 2025
Tender Value : 38.20 Lacs
 Lahul And Spiti - Himachal Pradesh
Tender for tender for provn of 04x50 kl grp water tank with connected items for water storage at sumdo in the area of age e/m (we) pooh under ge 863 ews; 1 excavation in trenches not exc 1.5 meter wide and not exc 1.5 metre in depth and getting outin soft/loose soil, for laying underground pipe etc, complete all as specified and directed . 2 returning, filling in incl spreading ,levelling watering and well ramming in layer n exc 25cm thick each layer , in soil, complete all as specified and directed . 3 removing excavated surplus materialto a distance n exc 50m and depositing where directed at level n. exc 1.5m above the starting point in any type of soil, complete all as specified and directed . 4 supply and laying 100 mm bore gi tubing medium grade including all fixture/ fittings for connection laid in trenched as per site requirement and directed by engr-in-charge. 5 supply and fix valves, sluice, flanged of class 1.6 pn, 100 mm (4”) dia complete all as specified and directed . 6 supply and fix non return sluice valve 100 mm dia complete all as specified and directed . 7 construction of brick masonary valve pit of size 600x600x600mm (internal dimension) incl necessary earth work and ms sheet 3 mm thick cover with angle iron frame 40 mm x 40 mm x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer all as shown in drg held with ge office incl of tapping of 100 mm gi pipeline from existing 100 mm gi pipeline complete all as specified directed. 8 supply fixing and testing monoblockpump sets, electric driven 415 v, tp suitable foroutdoor type rating capacity7.5hp kw (5.5) inclusive of 40 metre head pump model kds 8.30 ++ code no d12010750210 size in mm 80x65 including star delta starterall as directed by engr-in-charge. 9 s&f of smc/grp panel tank for water storage confirming with is 14399:1996 (part i & ii) and is-4249:1967 for fire retardant & nsf uk certified of 50,000 ltr capacity of size 5.00x5.00x2.00 mtr complete including necceassary connection of all inlet, outlet pipes with pump &all other neccessary fitments requiredat site for installation on ground complete all as specified and directed by engr-in-charge.note : standard non – insulated smc panels hot pressed moulded uv stabilized made from sheet moulding compounds (smc) composing of glass fiber and formulationsmc panels - made by hot pressed process mouldedbottom panel - smc panel 1000 x1000 x 70 mm, convex shapedrain panel & outlet panels - smc panel 1000 x1000 x 70 mm special design for complete drainside panel - smc panel 1000 x1000 x 70 mm, 1000 x 500 x 70mmceiling panel - smc panel 1000 x1000 x 70 mmmanhole -smc panel 1000 x1000 x 70 mm with 700 mm x 700 mm locable lid.thickness of the panels - as per is 14399 (part i & ii) 10 special accessories:corner frame - hdg steel vertical corner angle at four cornerssealing tape – non toxic 3mm thick with high level of resistance to ageing and superior recovery from compression (make : norseal by saint gobain)steel bolts for panel joints - hdg nut-bolts – 8.8 grade – m12 x 40mm – 8 nos. per sideair vent – pvc - air vent dia 100mm with insect proof mesh in sidewater level indicators - aluminium body level indicator – transparent tube typeexternal reinforcement - isi marked painted c channel supports at every 1-meter except in the corner of steel with anti corrosive paint and it is tie with top external painted tie rods.internal roof supports - frp square hollow section for roof supports – 50x50x5mmladders external ladder with wall mounting arrangementinternal ladder frp (if tank height is more than 1 meter)connection fixing - inlet/ outlet/ overflow/ drain inlet, outlet, overflow & drain – 50nb (as per table d – bs10)g.i. flange type with 9” long thread and nipple.base frame grillage - as per site condition, suitable for tank size and capacity. made out from m.s. channels/ beams with anticorrosive paints.base frame shall be measured & paid separately under relevant items. 11 pcc 1:3:6 type c-2 using 40mm stone agg as in foundation, filling and mass concrete on retaining walls complete all as specified and directed by engr-in-charge. 12 material and labour for providing pcc 1:2:4 type b1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, complete all as specified ansd as directed. 13 pre-cast cement concrete hollow block masonry type 1:3;6, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and directed by engr-in-charge. 14 m&l rendering 15mm thick on brick masonary in internal surfaces in cm 1:4 finished even and smooth with sagol finishcomplete all as specified and directed.
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • 4
  • 5
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : pcc drain
  • Precast Drain Tenders ,
  • Rcc Drain Tenders ,
  • Drainage System Tenders ,
  • Drain System Repair Tenders ,
  • Yard Drain Repair Tenders ,
  • Slab Drain Repair Tenders ,
  • Drainage Facilities Tenders ,
  • Catch Water Drain Repair Tenders ,
  • Water Drain Tenders ,
  • Drainage Repair Tenders

Get pcc drain Tender Alert...

377534

Related Searched Keywords : pcc drain

  • Underground Sewer Tenders From Maharashtra
  • Water Proof Tenders From Delhi
  • Culvert Slab Tenders From West-Bengal
  • False Celling Tenders From -Tamil-Nadu
  • Drilling Work Tenders From Andhra-Pradesh
  • Rcc Culvert Tenders From Gujarat
  • Excavating Tenders From Karnataka
  • Lift Irrigation Tenders From Uttar-Pradesh
  • Embankment Tenders From Rajasthan
  • Soil Work Tenders From Madhya-Pradesh

Read More


Tender Document

640954

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Drilling Machine Spares Tenders
  • Brickwork Tenders
  • Demolition Work Tenders
  • Bore Well Tenders
  • Roofing Work Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App