Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Pump Room
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of pump-room Tenders

List of latest pump-room Tenders in Indian Tenders. Click on any pump-room Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for pump-room Tenders.

Advance Search
  • All-Tenders (37)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Water Supply And Drainage
image image
State Government
TRN :49054058 |  26 May, 2025
Tender Value : 85.89 Lacs
 Rajnandgaon - Chhattisgarh
Tender for tenders for the remaining work in risk and cost in various villages of different development blocks of rajnandgaon under single village/retrofitting yojna under jal jeevan mission, which includes connecting and laying upvc/hdpe pipe line, construction of high level water reservoir, switch room, construction of boundary wall around high level water reservoir, supply and installation of submersible pump, electric connection from electricity department (cspdcl), installation of electrochlorinator, chlorinator room, supply of tap connections in homes and government institutions etc. and all other works, testing, trial run for 03 months, operation and maintenance work for 06 months (including complete work material, as per attached schedule)
  • View Tender
  • Document
  • Bid Support
2 Water Supply And Drainage
image image
State Government
TRN :49054064 |  26 May, 2025
Tender Value : 52.41 Lacs
 Rajnandgaon - Chhattisgarh
Tender for tenders for the remaining work in risk and cost in various villages of different development blocks of rajnandgaon under single village/retrofitting yojna under jal jeevan mission, which includes connecting and laying upvc/hdpe pipe line, construction of high level water reservoir, switch room, construction of boundary wall around high level water reservoir, supply and installation of submersible pump, electric connection from electricity department (cspdcl), installation of electrochlorinator, chlorinator room, supply of tap connections in homes and government institutions etc. and all other works, testing, trial run for 03 months, operation and maintenance work for 06 months (including complete work material, as per attached schedule)
  • View Tender
  • Document
  • Bid Support
3 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
4 Services
image image
State Government
TRN :49054531 |  29 May, 2025
Tender Value : 3.17 Crore
 Koppal - Karnataka
Tender for supply of food, groceries and vegetables for shri huligemma devi kshetra development authority huligi tq dt koppal - dry chilli byadigi hugi,dhaniya corinder seed hugi,sugar m30 madari hugi,jaggery hugi,avalakki medium hugi,bansi rava fine hugi,wheat hugi,rice hugi,millet powder hugi,sajji hugi,paper avalakki hugi,fried gram dall hugi,aduge soda hugi,vanaspatihugi,mango pickle hugi,kadalepuri/puffed rice churmuri hugi,tea powder tajmahal hugi,chiroti rava fine hugi,insence sticks hugi,fried gram flore hugi,maida flour hugi,kadale bija gound nut hugi,betel nuts hugi,bengal gram floor no 1 hugi,termeric stick hugi,green gram dal hugi,uradhal hugi,channa dal hugi,tur dal kof hugi,salt tata hugi,table salt tatahugi,tamarind hugi,dry chilli guntur hugi,tomatohugi,rubber band hugi,plastic cover 1 k.g hugi,plastic cover half k.g hugi,saajeera hugi,garam masala hugi,coriander powder hugi,kasturi mentia hugi,patri hugi,japatri hugi,limbu salt hugi,turmeric powder hugi,menthya hugi,jeera hugi,mustard seed hugi,stone flower hugi,pepper hugi,elachi cardamom hugi,nut meg hugi,poppy first seeds quality hugi,clove hugi,maggi hugi,cinnamon hugi,dry grapes 1st quality hugi,cashews nuts 1st quality hugi,mosaru nandini hugi,milk nandini hugi,chilli poweder nandi hugi,dry coconut hugi,garlic hugi,milk powder hugi,tiffin plates hugi,tea glass hugi,water glass hugi,donni hugi,muttala leaf hugi,patravali byagadi hugi,coffee powedr brue hugi,mtr sambar powder hugi,cocunut big size hugi,pumpkin hugi,cucumber hugi,brinzal hugi,all types of leaves mixed leaves hugi,ginger hugi,drum stic hugi,onion big size hugi,green chili hugi,beetroot hugi,carrot hugi,ajantha lemon yellow hugi,sungod oil hugi,potato hulgi,milk made kpl,lakshmi brand ingu kpl,surfexel powder hugi,detergent powder wheel hugi,toilet brush hugi,vessels cleaning brush hugi,bleaching powder hugi,toilet acid hugi,black phenyle hugi,horse gram hugi,green camphor hugi,ghee nandini hugi,nice broom hugi,stick broom hugi,washing soda hugi,daimond shugar hugi,colin spray hugi,room freshner hugi,wim bar hugi,nirma powderhugi,sabina powder hugi,beans hulgi
  • View Tender
  • Document
  • Bid Support
5 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
6 Security Services
image image
State Government
TRN :49054845 |  20 May, 2025
Tender Value : 0
 Kalyanpur - West Bengal
Tender for supply of miscellaneous articles for departmental store supply of miscellaneous articles for departmental store , sap 7th bn for the year 2025-26 f.y. by the commandant, sap 7th battalion, kalyanpur, asansol-5, paschim bardhaman . , laying and jointing pvc pipe. heading , 2 t engine oil (castrol) , 10 mm 2 core service wire alluminium, havells , 16 mm 4 core service wire alluminium havells , 6 mm 2 core service wire alluminium havells , 6 volt dry battery (sigma) , abdomen guard (good quality) , abeer dust (various colour) (good quality) , abrasive blade 14 stihl company , abrasive blade 5” (good quality) , abzorb- it 250 grms (cz-it) , ac remote battery(alkalinebattery 23a 12 v) (gp super) , adjustable wrench (taparia) , agromin medicine for mango tree (good quality) , allovera plant (good quality) , alluminium channel with glass for sliding window with all fittigs (apex) , alluminium hanger (good quality) , alluminium ladder (bathla/cipla plast) , alluminium paint (asian paint) , alluminium sheet (good quality) , alluminium utensil (jindal/raj) , amplifier (ahuja) , angle iron (2”) , angular stop cock (pvc) , anklet rexine (good quality) , apcolite (any colour ) 100 gram. (good quality) , aqua guard repair with new candle (good quality) , aquarium(24x18) (glass) (good quality) , arial powder (washing) , arodix(100gm) (good quality) , arrowshine board ( iron) (good quality) , arrow head iron (vrg) , arrowroot (good quality) , asbestos hook (iron) (good quality) , asbestos sheet 10x3.5 (good quality) , ashtrey (good quality) , asian paint (utasav) any colour , auto starter 20 amp single poll havells , axe (tata) 8” with handle , axe handle (wooden) (good quality) , b p set manual (accusure) , badminton cock yonex (06 pcs per box) , badminton net (good quality) , badminton racket (yonex) , bamboo (big) (good quality) , bamboo hook (4”) (good quality) , bandage (10 pcs per pkt) (sn) , band-aid (100 pcs) (johnson & johnson) , banner 4/3 (printed) (good quality) , banner 4/7 (printed) (good quality) , banner 4x6 (printed) (good quality) , banner 5x7 (printed) (good quality) , banner 6x8 (printed) (good quality) , banner 8/8 (printed) (good quality) , barbed wire (22 gages) (good quality) , barbed wire (24 gages) (good quality) , basin mirror (good quality) , basin mirror with tray (good quality) , basin pipe with socket3.5 ft (hind) , basin west cap (pvc) , basket ball (nivea) , basket ball hook (iron) (good quality) , basket ball net ( glaze) , batali 1 (iron) (good quality) , batali 1/2 (iron) (good quality) , bathroom basin(steel) (good quality) , bathroom tray steel (good quality) , battery ( eveready 950) , battery 1.5 volt (eveready) , battery aaa eveready (20 pcs pkt) , battery inverter 12 volt 100 amps (exide) , battery inverter 12 volt 150 amps (exide) , battery trolley (good quality) , batting gloves(duce) ss , batting pad(duce) ss , baygon spray 400 ml , bed cover double (bombay dying) , bed sheet double bed (bombay dyeing) , bed sheet single bed (bombay dyeing) , bed switch (anchor) 06 amp , belcha iron big size (good quality) , belcha iron medium size (good quality) , bench for barbell (good quality) , betadine lotion, 100 ml , bib cock (brass) (good quality) , bib cock pvc (loto) , bi-cycle (hercules/ hero) , bicycle with ball, seat, stand, half chain cover & lock (bsa 22”) , bicycle with ball, seat, stand, half chain cover & lock (hero jet 22”) , big and decorative dustbin (cello) 80 ltrs. , bitumen (good quality) , black half pant(cotton) (good quality) , black japan (rbc) , black pant ,06 pocket (raymond/gwalior) , black paper (for target) (good quality) , black tape (anchor) , blanket woolen double (good quality) , blanket woolen single (good quality) , bleaching powder (dcm) , blower/fan heater (bajaj) , blue dust (good quality) , body spray (temptation) 150 ml , body spray(nivea) 150 ml , body spray(park avenue) 150 ml , bone dust (har gura) (good quality) , bonti 15” with wooden butt (good quality) , bowl (laopala) , brass elbow 1/2 (ashirbad/ komol) , brass tee 1(tata) , brass tee 1.25(tata) , brass tee 1.5(tata) , brass tee 1/2(tata) , brass tee 2(tata) , brass tee 3(tata) , brass tee 3/4(tata) , broom stick (good quality) , broom with long bamboo stick (5) (good quality) , brown paper (thick) 4/4 feet(good quality) , brush cutter blade for lawn mower (good quality) , brush cutter machine (honda) , brush cutter trimmer line (good quality) , bulb 100 wt (philips) , bulb 200wt (philips) , bulb 60 wt (philips) , bulb holder buttom (anchor) , bulb holder pendent (anchor) , burnol(50 grms) , calling bell (bulbul/ sigma) , calling bell musical with remote (havells) , camouflage t-shirt half (tribeni), cotton , candle (big) (good quality) , cane(basket) jhuri (big size) (good quality) , car duster (cloth) (good quality) , car freshener 45 grm ( godrej aer) , car portable fire extinguisher 500 ml (isi marker) (good quality) , carbolic acid 100 grm (good quality) , carpet valvet (good quality) , carpet with all fittings (good quality) , carrom board 44” (good quality) , carrom board 52” (good quality) , carrom board stand wooden (good quality) , carrom guti with striker, fyber (good quality) , casarol 5 ltrs., (steel milton) , cashing¾ (good quality) , cashing 1 (good quality) , cashing t,l 1(good quality) , ceiling rose (anchor) , celling fan coil binding (good quality) , cello tape (big size) (good quality) , cess pool cleaning (6 x 4 x4) , chakti belna (wooden) (good quality) , chalni sand filter (good quality) , changer 63 amp 3 poll (microtek) , charger torch light (evereaday) , cheney (iron) (good quality) , china perek (different size) (good quality) , china pin for cassing (good quality) , chisel 6 (good quality) , chitkani aluminium 4”, 6” (good quality) , choke electronic (havells) , chopper (iron, 01 feet) (good quality) , cistern (hindware) , clamp for pvc pipe (iron) (good quality) , close up 200 grm , cloth clip(plastic) (good quality) , coal-tar (good quality) , codless loudspaker (ahuja) , coffee mug (good quality) , coir foot mat 12” x 36” (good quality) , coir foot mat 24” x 48” (good quality) , coir rope (good quality) , colgate active salt (200 grm) , colin 500 ml , colour packing paper (good quality) , commode (hindusthan) , commode (toilet) hand spray (hindware) , concrete cutter 4 (blade) (good quality) , concrete dhalai bench with installation (good quality) , concreted pillar 12’ (good quality) , concreted pillar 6’ (good quality) , condenser for fan 2.5 wt (good quality) , cone(football/ cricket practice use) (good quality) , cooper wire .75 mm (havels) , cooper wire 2.5 mm (havels) , copper wire (1 mm havells) , copper wire (1.5 mm havells) , copper wire 4 mm(havells) , corrugated tin (22 gage) 10’x 3 (tata) colour , corrugated tin (22 gage) 6’ x 3(tata) , corrugated tin (22 gage) 7’ x 3(tata) , corrugated tin (22 gage) 8’ x 3(tata) , corrugated tin (22 gage) 9’ x 3(tata) colour , corrugated tin (tata, 9 x 3) (22 gage) , cotton (09 pcs per box) (good quality) , cotton cloth (good quality) , cotton duster (good quality) , cotton hand gloves (good quality) , cotton rope (thick) (good quality) , cotton rope (thin) (good quality) , covered round bamboo fencing to protect new planted trees (5’x8’) (good quality) , crape bandage (good quality) , cricket ball(duce) club/azone , cricket bat (ss kashmir wilow) , cricket bat (ss ton, english willow ) , cricket bat(duce) ss , cricket facial helmet(duce)ss , cricket mat full pitch (22 yards) (good quality) , crowber 4 feet(iron) (good quality) , crystal knife (good quality) , cup plate (bone china) 6 pieces each per set , cup plate (borosil)6 pieces each per set , cup plate (laopala) 6 pieces each per set , curtain ring (good quality) , curtain socket, steel (good quality) , curtain tape (good quality) , cushion chair (kurl-on) , cycle chain (good quality) , cycle nylon tyre (ralson) , cycle padle (good quality) , cycle pumper (good quality) , cycle spoke (good quality) , cycle tube (ralson) , dabu (iron) hata big size (good quality) , dalda pipe 1/2 pvc (good quality) , dalda pipe 3/4 pvc (good quality) , dalda pipe join l (good quality) , dalia (flower young plant) (good quality) , dao/katari (iron) (good quality) , dap fertilizer (good quality) , delivery pipe for water 4(hind) , deto fixed 100 grm (good quality) , dettol hand wash 175 ml (refill pack) , dettol hand wash 200 ml (bottle) , dettol lotion 200 ml , dettol lotion 500 ml , dettol soap 75 gm , dinner set (borosil, 13 pcs set) , dinner set (laopala, 23 pcs set) , dinner spoon steel (good quality) , dinner table with aluminum cover (4’x5’x’2.5’) (good quality) , disposal latex gloves(100 pcspkt) (good quality) , distemper (asian tractor ) , door closer (good quality) , door curtain(4’ x 6’) (good quality) , door mat best (18x36) (good quality) , door mat velvet (24”x36”) (good quality) , dove soap 100 grm , drain brush with stick (good quality) , drill bit for concrete (good quality) , drill bit for metal (good quality) , drill bit set, wooden (good quality) , drill machine (bajaj ) , drinking water glass (borosil) , dust mask (good quality) , dustbin with lid (syntax) 10 ltrs , dustbin, big (syntax) 60 ltrs , ear plug (good quality) , earthing rod, iron 10 (good quality) , earthing wire (good quality) , elbow cap (iron) (good quality) , elbow iron 1.5”(tata) , elbow iron 1/2” (tata) , elbow iron 1”(tata) , elbow iron 3/4(tata) , electric iron (bajaj) , electric iron (philips) , electric kettle, best prestige, 1.5 ltrs. , electric wooden planner machine (good quality) , emergency light chargeable (khaitan/bajaj) , emery paper (good quality) , empty cement bag (plastic) (good quality) , empty oil drum (50 ltrs) (good quality) , end cap 1.25 (good quality) , exercise cycle(dolphy/durafit) , exhaust fan (crompton) 12 , exhaust fan (crompton) 18 , extension cord (skill) , eye protective glass (good quality) , ezee (200 ml) , face mask (cotton cloth) (good quality) , face mask generic (with nose clip) 50 pcspkt(good quality) , face sheild (good quality) , false ceiling grass board with fitting (good quality) , false ceiling parris board with fitting (good quality) , fan condenser(bajaj) , fan regulator electronics(usha) , fevi gum 200 ml , fevi stick 22 gm , fevicol ddl , fevicol sh , fiber chair with handle (supremo) , fiber chair without handle (supremo) , fiber table (supremo) , fibre name plate 1.5’ x 1’ (good quality) , fibre name plate 1’ x 3” (good quality) , fibre name plate 1’ x 4” (good quality) , figure 11 target (wooden) (good quality) , figure 11 target paper (good quality) , file carrier 22” (vip) , finit spray gun plastic (good quality) , fire bucket with iron structure(4 pcs bucket) (good quality) , fire extinguisher afff (mechanical foam) capacity 9 ltrs (good quality) , fire extinguisher co2 validity 5 years capacity 6.5 ltrs (good quality) , first-aid box with medicine(milton) , flask steel body, 1ltrs. milton , flexible wire (havells) , floor mat complete setting (good quality) , floor mop with bucket (good quality) , flower boukey (basket type) (good quality) , flower boukey(tube type) (good quality) , flower pot 10”(clay) with flower (good quality) , flower pot 12”(clay)with flower (good quality) , flower pot 15”(clay)with flower (good quality) , flower pot 18” (clay)with flower (good quality) , flower pot 20” (clay)with flower (good quality) , flower pot 8”(clay)with flower (good quality) , flower saplings tulip (good quality) , flower tub (brass) with flower (good quality) , flower tub (cement) with flower (good quality) , flower vass (brass) good quality (good quality) , fluroscent paint 400 ml (good quality) , foot ball net (good quality) , foot ball(nivea) , ful jharu (fyber) (good quality) , funnel plastic (big) (good quality) , funnel plastic (medium) (good quality) , funnel plastic (small) (good quality) , fuse6 mm (havells) (good quality) , fyber switch board with cutting (10 x 1) (good quality) , g.i socket ½” (tata) , g.i socket 1.5” (tata) , g.i socket 1” (tata) , g.i socket 2.5” (tata) , g.i socket 2” (tata) , g.i socket 3/4” (tata) , g.i. bucket (tata-14) , g.i. elbow ½” (tata) , g.i. elbow 1”(tata) , g.i. elbow 1½”(tata) , g.i. elbow 2”(tata) , g.i. elbow 2½”(tata) , g.i. elbow 3/4” (tata) , g.i. garden net (good quality) , g.i. gate-valve 1.5” (tata) , g.i. gate-valve 1/2” (tata) , g.i. gate-valve 1” (tata) , g.i. gate-valve 2.5” (tata) , g.i. gate-valve 2” (tata) , g.i. gate-valve 3/4” (tata) , g.i. nipple ½” (tata) , g.i. nipple 1.5” (tata) , g.i. nipple 1” (tata) , g.i. nipple 2.5” (tata) , g.i. nipple 2” (tata) , g.i. nipple 3/4” (tata) , g.i. pipe (tata ½”) , g.i. pipe (tata 1”) , g.i. pipe (tata 1½”) , g.i. pipe (tata 2”) , g.i. pipe (tata 2½”) , g.i. tee ½” (tata) , g.i. tee 1.5” (tata) , g.i. tee 1” (tata) , g.i. tee 2.5” (tata) , g.i. tee 2” (tata) , g.i. tee 3/4” (tata) , g.i. union ½” (tata) , g.i. union 1.5” (tata) , g.i. union 1” (tata) , g.i. union 2.5” (tata) , g.i. union 2” (tata) , g.i. union 3/4” (tata) , g.i. wire (thick) (good quality) , gammexanepowder (good quality) , garden scissor 18” (good quality) , garden umbrella (k.c.paul) , gas cylinder pipe(good quality) , gas cylinder regulator (good quality) , gas lighter (good quality) , gas oven (burner type) (good quality) , gas oven (prestige) , gas oven (three furnace type) (good quality) , gas oven marbel (prestige) , gas oven regulator (good quality) , geoline 20ml (good quality) , geyser 15 ltrs (bajaj) , geyser 25 ltrs (bajaj) , glass lid (good quality) , globe light big (antiklyts) , globe light small (antiklyts) , gloves woollen (good quality) , glow sign board with all fitting (good quality) , glucose d 200 grm , glycerin soap (125 grm) (pears) , goal keeper gloves(football) (good quality) , good knight machine , good night refill 60 night , grease (good quality) , grinder machine (bosch) cutter , ground sheet (satranji) 18/24 feet (good quality) , ground sheet (satranji) 24/30 feet (good quality) , gumboot (good quality) , hacksaw blade (double head) bipco , hacksaw frame (good quality) , halogen holder 500 wt (good quality) , halogen light complete set (havells) , hamal dista(medium) (good quality) , hammer 1 kg (iron) (good quality) , hammer 500 grm (iron) (good quality) , hand bath spray (plastic) (good quality) , hand bath spray (steel) (good quality) , hand gloves for electrical work (good quality) , hand sanitizer liquid( dettol/himalaya) 05 ltrs , hand sanitizer liquid( dettol/himalaya) 100 ml , hand sanitizer liquid( dettol/himalaya) 500 ml , hand sanitizer liquid(bacol) 100 ml , hand sanitizer liquid(gel) 05 ltrs (bacol) , hand shower with all fittings (good quality) , hand spray bottle (fyber/plastic) (good quality) , handle brass ball valve 1.25 (good quality) , hanger, plastic (good quality) , hanger, steel (good quality) , hansua (iron path) big (good quality) , hansua (karat/ blade type) (good quality) , harpic blue/ red 500 ml , hart starting clap board (good quality) , hata steel ordinary (good quality) , havells water heater 15 ltr (puro plus) , hawkins pressure cooker 10 lts , hawkins pressure cooker 3 lts , hawkins pressure cooker 5 lts , helmet repair (good quality) , hessian cloth (good quality) , hit black 400 ml , hit red 400 ml , hose pipe 3 / 20 (shakti) , hose pipe polythene (shakti) , hot pot 1440 ml (milton) , hot pot 1500 ml (milton) , hot pot 2700 ml (milton) , induction cooker 5 ltrs (bajaj) , induction oven 2000 wt, havells , induction oven 2000 wt, prestige , inner thigh guard(duce)ss , inverter 1200 watt (microtech) , inverter 1500 watt (microtech) , iron angle (good quality) , iron big tawa (good quality) , iron chimta (good quality) , iron clamp 2” (good quality) , iron clamp 3” (good quality) , iron cot repair (good quality) , iron hamal dista big (good quality) , iron hamal dista small (good quality) , iron katari(small) (good quality) , iron khunti 20” (good quality) , iron korai (big) (good quality) , iron korai (medium) (good quality) , iron tawa (good quality) , j hook (iron) (good quality) , jhajhra iron big size (good quality) , jhul jharu (fyber) (good quality) , jungle cutter (good quality) , jute (good quality) , kabja 2 (good quality) , kabja 4” (good quality) , kanta spoon (good quality) , keeping gloves (ss) for deuce ball , kent super plus mineral ro water purifier (15 ltrs/ hour) , kent water purifier 23 liters , khalpa with all fitting (good quality) , khurpi (good quality) , kurni (good quality) , laxman rekha (cockroach) , led ceiling light square 09 wt (good quality) , led ceiling light square 12 wt (good quality) , led ceiling light square 15 wt (good quality) , led flat light 100 wt, philips , led flat light 50 wt, philips , led lamp (syska) 15 wt. , led lamp (syska) 9 wt. , led lamp 03 wt (havells) , led lamp 05 wt(havells) , led lamp 07 wt(havells) , led tubelight set 18 watt syska , led tubelight set 20 watt syska , life buoy soap (125 gm) , lime brush (good quality) , lime dust (camel) , liquid soap 05 ltrs jar (good quality) , lizol 500 ml (disinfectant) , lock & key (6 leaver) (godrej) , lock & key (7 leaver) (godrej) , lock & key (8 leaver) (godrej) , lock & key (9 leaver) (godrej) , long hand gloves (good quality) , lux soap (big)125 grm , m.c.b. 6 ampsingle pole channel,(havells) , m.c.b. 6 ampsingle pole switch(havells) , m.c.b. box (havells) , m.c.b.10 ampsingle pole moduler (havells) , m.s. pipe 2 x 20 (tata) , macheti anti grass (500 ml) (good quality) , main switch ( jj 32 amp) , main switch ( jj 63 amp) , main switch 32amp 02 poll (havells) , main switch 63 amp03 pole(havells) , malefemale plug (priti) , matress double (kurl-on) , matress single (kurl-on) , maxican lawn grass (good quality) , mcb 16 amp single poll ,switch,anchor , mcb 16 amp single poll moduler, anchor , measuring tape 100 ft. (good quality) , medicine ball (adrenex/ dejure) , memento fyber 12 (good quality) , memontos acrylic 8/10/12 (good quality) , memontos brass 8/10/12 (good quality) , memontos wooden 8/10/12 (good quality) , mess tin set (alluminium) (good quality) , metal light 250 wt philips (complete set) , metal light 400 wt philips (complete set) , micro oven samsung 5 ltrs. , microphone battery (good quality) , microphone, cordless(sony) , microwave oven(prestige) , mike complete set, ahuja , milton tiffin box (big) 05 box , milton tiffin box(medium) , mini fogging machine (super powerful) (good quality) , mixer grinder 750wt. bajaj , momo maker (small) (good quality) , monoblock pump 2 hp with all accessories (good quality) , moov gel 30 grm , moov spray 100 ml , mortein coil green , mosquito net, double bed (good quality) , mosquito net, single bed (good quality) , moving wiper (floor cleaner) (good quality) , m-seal (big packet) (good quality) , muretic acid (good quality) , nail wire (different size) (good quality) , national flag (6 x 4 khadi) (good quality) , national flag (6 x 4 silk) (good quality) , national flag 4’/ 3’ (good quality) , neosprin 50 grm , night lamp (good quality) , nim khoil (good quality) , nylon rope (good quality) , odomosh 50 grm , odonil packet 50 grm , open box pvc (3”x3”) (good quality) , open box pvc (3”x4”) (good quality) , open box pvc (6”x4”) (good quality) , ordinary lock & key (06 lever)(link) , ors (good quality) , p.t shoe(gold star) any colour , paint alluminium (asian paint) , paint brush 1.5” (good quality) , paint brush 2” (good quality) , paint brush 3” (good quality) , paint brush 4” (good quality) , pan cleaning brush (good quality) , paper decoration flag (cutting, various colour) (good quality) , pedal dustbin (good quality) , pedestal fan high speed, fiber, orient , pencil battery(nipppo) , pepsodent 200 grm , phenyle bengal chemical (black) (bengal chemical) , phenyle bengal chemical (white) (nimyle) , photography umbrella (good quality) , piano socket 06 amp 2 pin(anchor) , piano socket 06 amp 5 pin(anchor) , piano socket 16 amp (anchor) , piano switch 6 amp (anchor) , piano switch 16 amp (anchor) , pick axe (iron)(good quality) , pillar cock (crosser) hind ware , pillow (good quality) , pillow (bombey dying) , pillow (cotton) (kurl on) , pillow cover (bombay dyeing) , pillow (kurl-on) , pilow cover (good quality) , pitch chot (good quality) , plaster paris (good quality) , plastic bucket 20 liter (cello) , plastic bullet 1.5 (good quality) , plastic disposable bag (large size) , plastic jhuri (basket) (good quality) , plastic jug (good quality) , plastic mug (cello) , plastic pipe pvc1” (oriplast) , plastic pipe pvc 1.5” (oriplast) , plastic pipe pvc 3/4” (oriplast) , plastic sheet 7’ x 3’ (good quality) , plastic tub8 (good quality) , plus taparia (10”) , plus taparia (8) , ply-wood 04 mm (century) , ply-wood 06mm (century) , ply-wood 08mm (century) , ply-wood 10mm (century) , ply-wood 12mm (century) , ply-wood 16 mm (century) , ply-wood 18 mm (century) , ply-wood 19 mm (century) , plywood door( heavy with design) (good quality) , polymer door (3’x6.5’) with fitting (good quality) , polythene pipe ¾” (hind) , polythene sheet 18’x18’ (good quality) , polythene sheet 18’x24’ (good quality) , primer for wall painting (asian paint) , primer for wooden/ iron (asian paint) , profile 6x3 (thick) (good quality) , pudding (good quality) , pulse oximeter, accusure/dr. trust , pvc 1 way box (good quality) , pvc 3 way box (good quality) , pvc 45 degree elbow (ashirbad/ komol) 1.25 , pvc 45 degree elbow (ashirbad/ komol) 1.5 , pvc 45 degree elbow (ashirbad/ komol) 1/2 , pvc 45 degree elbow (ashirbad/ komol) 3/4 , pvc 45 degree elbow (ashirbad/ komol) 1 , pvc 45 degree elbow (ashirbad/ komol) 2 , pvc 45 degree elbow (ashirbad/ komol) 3 , pvc 5 way box (ashirbad/ komol) , pvc 8 way box (ashirbad/ komol) , pvc ball valve 1(ashirbad/ komol) , pvc ball valve 1.25(ashirbad/ komol) , pvc ball valve 1.5(ashirbad/ komol) , pvc ball valve 1/2(ashirbad/ komol) , pvc ball valve 2(ashirbad/ komol) , pvc ball valve 3(ashirbad/ komol) , pvc ball valve 3/4(ashirbad/ komol) , pvc band (elbow 4”) calcutta , pvc cross 4’ (good quality) , pvc elbow 1(ashirbad/ komol) , pvc elbow 1.25(ashirbad/ komol) , pvc elbow 1.5(ashirbad/ komol) , pvc elbow 1/2 (good quality) , pvc elbow 1/2(ashirbad/ komol) , pvc elbow 2(ashirbad/ komol) , pvc elbow 3(ashirbad/ komol) , pvc elbow 3/4(ashirbad/ komol) , pvc end cap 1 (ashirbad/ komol) , pvc end cap 1.25 (ashirbad/ komol) , pvc end cap 1.5 (ashirbad/ komol) , pvc end cap 1/2 (ashirbad/ komol) , pvc end cap 3/4 (ashirbad/ komol) , pvc end pluck 1(ashirbad/ komol) , pvc end pluck 1.25(ashirbad/ komol) , pvc end pluck 1.5(ashirbad/ komol) , pvc end pluck 1/2(ashirbad/ komol) , pvc end pluck 2(ashirbad/ komol) , pvc end pluck 3(ashirbad/ komol) , pvc end pluck 3/4(ashirbad/ komol) , pvc female thread socket (ashirbad/ komol) 1 , pvc female thread socket (ashirbad/ komol) 1.5 , pvc female thread socket (ashirbad/ komol) 2 , pvc female thread socket (ashirbad/ komol) 3 , pvc female thread socket (ashirbad/ komol) 3/4 , pvc female thread socket (ashirbad/ komol)1.25 , pvc female thread socket (ashirbad/ komol)1/2 , pvc join box 4/4 (good quality) , pvc join box 4/6 (good quality) , pvc large elbow 1(ashirbad/ komol) , pvc large elbow 1.25(ashirbad/ komol) , pvc large elbow 1.5(ashirbad/ komol) , pvc large elbow 2(ashirbad/ komol) , pvc large elbow 3(ashirbad/ komol) , pvc male thread socket (ashirbad/ komol) 1 , pvc male thread socket (ashirbad/ komol) 1.5 , pvc male thread socket (ashirbad/ komol) 2 , pvc male thread socket (ashirbad/ komol) 3 , pvc male thread socket (ashirbad/ komol) 3/4 , pvc male thread socket (ashirbad/ komol)1.25 , pvc male thread socket (ashirbad/ komol)1/2 , pvc pipe (electric wiring ½”) calcutta , pvc pipe 1 (ashirbad/ komol) , pvc pipe 1.25(ashirbad/ komol) , pvc pipe 1.5(ashirbad/ komol) , pvc pipe 1/2 (ashirbad/ komol) , pvc pipe 1/2 (ashirbad/ komol) , pvc pipe 2(ashirbad/ komol) , pvc pipe 3(ashirbad/ komol) , pvc pipe 3/4(ashirbad/ komol) , pvc rain water pipe clam (4”) calcutta , pvc roducer busing 1(ashirbad/ komol) , pvc roducer busing 1.25(ashirbad/ komol) , pvc roducer busing 1.5(ashirbad/ komol) , pvc roducer tee 1(ashirbad/ komol) , pvc roducer tee 1.25(ashirbad/ komol) , pvc roducer tee 1.5(ashirbad/ komol) , pvc roducer tee 1/2(ashirbad/ komol) , pvc roducer tee 2(ashirbad/ komol) , pvc roducer tee 3(ashirbad/ komol) , pvc roducer tee 3/4(ashirbad/ komol) , pvc saddle (electric wiring ½”) calcutta , pvc saddle clamp 1(ashirbad/ komol) , pvc saddle clamp1.25(ashirbad/ komol) , pvc saddle clamp1.5(ashirbad/ komol) , pvc saddle clamp1/2(ashirbad/ komol) , pvc saddle clamp3/4(ashirbad/ komol) , pvc socket 1(ashirbad/ komol) , pvc socket 1.25(ashirbad/ komol) , pvc socket 1.5(ashirbad/ komol) , pvc socket 1/2(ashirbad/ komol) , pvc socket 2(ashirbad/ komol) , pvc socket 3(ashirbad/ komol) , pvc socket 3/4(ashirbad/ komol) , pvc solvent 500 grm (good quality) , pvc tank nov 1(ashirbad/ komol) , pvc tank nov 1.5(ashirbad/ komol) , pvc tank nov 1/2(ashirbad/ komol) , pvc tank nov 2(ashirbad/ komol) , pvc tank nov 3(ashirbad/ komol) , pvc tee (4”) calcutta , pvc tee (electric ½”) calcutta , pvc tee 1(ashirbad/ komol) , pvc tee 1.25(ashirbad/ komol) , pvc tee 1.5(ashirbad/ komol) , pvc tee 1/2 (ashirbad/ komol) , pvc tee 1/2(ashirbad/ komol) , pvc tee 2(ashirbad/ komol) , pvc tee 3(ashirbad/ komol) , pvc tee 3/4(ashirbad/ komol) , pvc teflon tape 200 grm (good quality) , pvc union 1(ashirbad/ komol) , pvc union 1.25(ashirbad/ komol) , pvc union 1.5(ashirbad/ komol) , pvc union 1/2(ashirbad/ komol) , pvc union 2(ashirbad/ komol) , pvc union 3(ashirbad/ komol) , pvc union 3/4(ashirbad/ komol) , pvc water tank 1000 ltrs (syntax) , pvc water tank 1500 ltrs (syntax , pvc water tank 500 ltrs (syntax) , racket mosquito (good quality) , rain water pipe(good quality) , rain water pipe clamp (good quality) , red oxide (good quality) , red salu (cloth) (good quality) , rice cooker 03 liter (good quality) , robin blue (good quality) , room freshener(godrej aer) 240 ml , room heater (bajaj) , room freshner premium 240 ml (good quality) , rope nylon thick (good quality) , royal shine (good quality) , rubber handgloves (good quality) , rubber pipe 1 (good quality) , rucksuck (good quality) , safed powder , saiphone valve (pan) (good quality) , sanitary pan, (hindustan) , sanitary pipe pvc (good quality) , sarasi (steel) (good quality) , saving kit park avenue , savlon liquid 200 ml , savlon soap 200 gms. , scissor (big) (good quality) , scissor (small) (good quality) , scotch brite , screw 1.5 full thread (good quality) , screw 1.5” (good quality) , screw 1/2 (good quality) , screw 3” (good quality) , screw driverwith cover 12 (taparia ) , sensodyne(tooth paste)200 grm , service wire16 mm 4 core alluminium, havells , service wire 16mm 2 core alluminium, havells , sil and nora (big) (good quality) , sil and nora (small) (good quality) , siris paper 4x4 (good quality) , snow-sem berger (25 kgs) (good quality) , socket anchor 6 amp 2 pin , sodium hypochlorite 05 ltrs jar (good quality) , solvent 100 grm (good quality) , sound box big (ahuja) , sound box small (ahuja) , sound system (ahuza) , spade big size with handle , spade handle (wooden) (good quality) , spade kata (good quality) , spoon steel (big) (good quality) , spoon steel (medium) (good quality) , spoon with spoon stand (steel)(good quality) , sports shoe(reebok/ adidas/puma) , spray bottle (plastic) (good quality) , stand fan (usha) , stand fan coil binding (good quality) , steel glass (good quality) , steel handi (medium) (good quality) , steel handi (small) (good quality) , steel hata (good quality) , steel jug (good quality) , steel kettle big (good quality) , steel khunti (good quality) , steel panja (good quality) , steel pipe (good quality) , steel sarashi (good quality) , steel soap case (good quality) , steel thala (good quality) , steel tiffin box, big(05 bati set) (good quality) , steiner (piditin) 100ml (asian) , stethoscope (dr. morepen) , still gamla (good quality) , still tray (good quality) , street light led (bajaj) , submersible pump 2 hp ( crompton) , succession board with acp sheet (golden sticker) , sunlight powder , sunmica6/4 with cutting (good quality) , sunmica8/10 with cutting (good quality) , sunmica8/6 with cutting (good quality) , surf excel matic(front/ top/side loader) , surf excel powder , surf excel soap (big) 200 grm , sutli (good quality) , sweeper trolly (iron) (good quality) , swimming costume (good quality) , table cloth blue/ merun (6 x 4 ) bombay dying , tar-pin oil (good quality) , tea chakni (good quality) , tea fiask steel 10 ltrs (good quality) , tea flask 1liter (milton) , tea flask 2liter (milton) , tea flask 3liter (milton) , tea flask big steel 20 liters (good quality) , tea pot set (laopala) , tea table (wooden with glass 2x3) (good quality) , tennis ball (khanna super) , tissu paper stand (fyber) , tissue paper (25 pieces packet) (good quality) , toilet pan (indian) big size (good quality) , top 16 amp (anchor) , top 6 amp (anchor) , towel big (bombay dying) , towel medium (bombay dying) , towel small (bombay dying) , tractor emulsion (asian paint) , tripol (orange/green colour) 24 x 30 (good quality) , trophy (big) (good quality) , trophy (medium) (good quality) , trophy (small) (good quality) , tube light complete set (philips 40wt) 4 feet , tube light frame ( good quality) 4 feet , tube light holder (philips) , tube light rod 40 wt, philips/surya, 4 feet , tuli brush 0 to 08 number (good quality) , tulu pump 2 hp (v-guard) , ujjala 250ml , umbrella big (kc paul) , umbrella folding (kc paul) , umbrella plain (kc paul) , unit flag 3’ x 2’ (silk) (good quality) , unit flag 6’ x 4’ (cotton) (good quality) , unit flag 6’ x 4’ with embroydary stitch (good quality) , unit flag velvet cloth(3.6x5) (good quality) , urea (good quality) , vapor bulb (250 wt.)philips , vapor choke (250 wt.)philips , vapor condenser philips , vapor set (750 wt.) philips , vapour chokh, bajaj , vapour complete set, bajaj/ philips , vapour condenser, bajaj , vapour ignator, philips , vapour lamp copper, bajaj , vapour lamp sodium, bajaj , vauxhall search light , vegetable seeds (good quality) , velvet cloth (good quality) , vertical curtain (good quality) , vim bar (300gm) , vim liquid (250 ml) , vitamin for mango tree, 500ml (good quality) , volini gel 50 grm , volini spray (200ml) , volley ball net (good quality) , volley ball, cosco , wall fan with speed controller (orient) , wall mirror (2’x4’) (good quality) , wall putty (asian paint) , wall-clock ajanta big size , water drum plastic with lid 80ltr (good quality) , water filter 23 ltrs pure-it , water glass (borosil) , water jhinjiri (plastic) (good quality) , water tank cleaning (1000 ltrs) (good quality) , wbp flag velvet cloth (3.6x5) (good quality) , weight machine automatic (good quality) , west pipe (good quality) , white board with stand (good quality) , white half pant (good quality) , white p.t. vest (triveni) , white socks (good quality) , white table cloth (cotton 6 x 4) (good quality) , wild stone soap 125 grm (good quality) , window curtain 3’x4’ (good quality) , window glass with all fitting (good quality) , wiper (good quality) , wire cutter, taparia , wooden board8/6 (good quality) , wooden board 6/4 (good quality) , wooden board 8/10 (good quality) , wooden circular saw (good quality) , wooden door6/3 (good quality) , wooden high bench & low bench set (good quality) , wooden target with hessian cloth and picture (7.5’ x 4.5’ x 4.5’ x 7.5’) (good quality) , wooden window 3/4 & 4/4 (good quality) , wrench set (taparia) , wrist band (various colour) (good quality) , yellow mati (good quality) , cutting weeds from building wall , tea flask 20 ltr/tea container 20 ltr , copper wire 1mm (havells) , copper wire 1.5mm(havells) , camouflage big umbrella , kushion chair(supreme) , big iron tawa(good quality) , football jersey with pant(good quality) , bullet chainsaw repairing & servicing , 25 hp & 40 hp out boat motor servicing , generator 10.5 kva repairing , synthetic oil , coolent , foot pumper , herbiside(glycel) , weight belt , broom stick , fibre name plate 1x3 , swing(outdoor metal iron) one seater , swing(outdoor wooden) one seater , seasaw(wooden)big , flask(steel body)1.5 ltr milton , arrow shine board(iron) , 300 amp socket fuse , g.i pipe (tata 4) , t-flag (38cm/72cm) , unit flag (embroidery)(72x48) , water bottle (250ml,kinley) , rice plate (lao pala) , 3-phase 7.5 hp motor pump repairing , tulu pump (water supply pump) repairing , bathroom wall mirror(good quality) , water tank 500 ltrs(supreme) , water tank 1000 ltrs(supreme) , snake catcher alluminium stick(4.4) , commode flush valve(hindware) , motor pump servicing
  • View Tender
  • Document
  • Bid Support
7 Rural Development
image image
Local Bodies
TRN :49055155 |  26 May, 2025
Tender Value : 0
 Ayodhya - Uttar Pradesh
Tender for tender for estimate for construction of 300x200mm size of 132/120mdeep new tubewell and allied work from bachhra sultanpur at ayodhya. - construction of tube well 300x200 mm size 2 pumping plant of 700 lpm capacity with 75 m head and allied works with all accessories and chlorinating plant 3 laying of 150mm dia dl k-7 rising main pipeline and other works 4 construction of pupm house (size 3.6x3.0x3.0) cum chlorinating room (size 1.8x2.6x3.0) 5 internal electrification of new pump house 6 laying of cable
  • View Tender
  • Document
  • Bid Support
8 Power Plant
image image
corporations/Associations/Others
TRN :49056804 |  23 May, 2025
Tender Value : 18.27 Lacs
 Prayagraj - Uttar Pradesh
Tender for tender for annual civil & electrical m&r work for residential building situated at 20-clive road hydel colony, prayagraj - earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for all kinds of soil. 2 supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 3 surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. for all kinds of soil. 4 excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 5 providing and laying in position cement concrete of grade 1:1½:3 (1 cement: 1½ coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 6 providing and laying in position cement concrete of grade1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 7 providing and laying in position cement concrete of grade 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 8 providing and laying cement concrete 1:1½:3 (1 cement: 1½ coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 9 providing and fixing up to floor five level precast cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering complete. 10 providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 11 extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 12 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 13 providing and laying in positiongrade 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 14 providing and laying in positiongrade 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 15 reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 16 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 17 centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete 18 centering and shuttering including strutting, propping etc. and removal of form for walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 19 centering and shuttering including strutting, propping etc. and removal of form forsuspended floors, roofs, landings, balconies and access platform 20 centering and shuttering including strutting, propping etc. and removal of form for shelves (cast in situ) 21 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers 22 centering and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts 23 centering and shuttering including strutting, propping etc. and removal of form for stairs, (excluding landings) except spiral-staircases 24 centering and shuttering including strutting, propping etc. and removal of form for spiral staircases (including landing) 25 centering and shuttering including strutting, propping etc. and removal of form for small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 26 centering and shuttering including strutting, propping etc. and removal of form for small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 27 centering and shuttering including strutting, propping etc. and removal of form for weather shade, chajjas, corbels etc., including edges 28 centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 29 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 30 mild steel and medium tensile steel bars for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 31 mild steel and medium tensile steel bars for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 32 smooth finishing of the exposed surface of r.c.c. work with 6 mm thick cement mortar 1:3 (1 cement : 3 fine sand). 33 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 34 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand) 35 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand) 36 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) 37 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. cement mortar 1:4 (1 cement :4 coarse sand) 38 providing and fixing 18 mm thick granite stone slab of colour black, cherry/ruby red gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (area of slab over 0.50 sqm) 39 providing edge moulding to 18 mm thick granite workcounters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer-in-charge. 40 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 41 providing and fixing plywood 4 mm thick, one side decorative veneer conforming to is: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : 42 providing and fixing 4mm thick coir veneer board, isi marked is : 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 43 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 44 providing second class teak wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 45 providing and fixing 2nd class teak wood size 50x12 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 46 providing and fixing second class teak wood panelled or panelled and glazed 30 mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of engineer-in-charge. (note:- butt hingesand necessary screwsshall be paid separately) 47 providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 48 providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 49 providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned and chemically treated hollock wood) 50 providing and fixing35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned selected planks of sheesham wood) 51 providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned selected planks of sheesham wood) 52 providing and fixing30mm thick panelled or panelled & glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(second class teak wood including isi marked anodised aluminium butt hinges with necessary screws) 53 providing and fixing isi marked 35mm thick flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 54 providing and fixing isi marked 30mm thick flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 55 providing and fixing isi marked 35mm thick flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 56 extra for providing and fixing flush doors with on one side only decorative veneering instead of non decorative isi marked flush door shutters conforming to is: 2202 (part i) 57 providing and fixing 12mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 58 providing and fixing 20mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 59 providing and fixing 25mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 60 providing and fixing 20mm dia (heavy type) nickel plated m.s. pipe curtain rods with nickel plated brackets : 61 providing and fixing 25mm dia (heavy type) nickel plated m.s. pipe curtain rods with nickel plated brackets : 62 providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 63 providing and fixing 125x65x2.12 mm isi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 64 providing and fixing 100x58x1.90 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 65 providing and fixing 75x47x1.70 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 66 providing and fixing 50x37x1.50 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 67 providing and fixing 150 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 68 providing and fixing 125 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 69 providing and fixing 100 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 70 providing and fixing 250x16 mm isi marked oxidised m.s. sliding door bolts with nuts and screws etc. complete (copper oxidised as per is 1378) 71 providing and 250x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 72 providing and 200x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 73 providing and 150x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 74 providing and 100x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 75 providing and fixing isi marked 85x42 mm oxidised m.s. pull bolt lock conforming to is : 7534 with necessary screws bolts, nut and washers etc. complete (copper oxidised as per is 1378). 76 providing and fixing 125 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 77 providing and fixing 100 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 78 providing and fixing 75 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 79 providing and fixing 150 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 80 providing and fixing 115 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 81 providing and fixing 90 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 82 providing and fixing 300 mm (weighing not less than 330 grams) oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete (copper oxidised as per is 1378) 83 providing and fixing 125mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 84 providing and fixing 100mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 85 providing and fixing 75mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 86 providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 87 providing and fixing triple strip vertical type magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 88 providing and fixing double strip (horizontal type) magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 89 providing and fixing factory made upvc door frame made of upvc extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. the hinge side vertical of the frames reinforced by galvanized m.s. tube of size 19 x 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of engineer- in-charge (extruded section profile size 48x40 mm) 90 providing and fixing factory made upvc door frame made of upvc extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. the hinge side vertical of the frames reinforced by galvanized m.s. tube of size 19 x 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of engineer- in-charge (extruded section profile size 42x50 mm) 91 providing and fixing 12 mm thick fire retardant plywood conforming to is: 5509 panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 92 providing and fixing cup board shutters 25 mm thick, with pre-laminated flat pressed three layer particle board or graded wood particle board is: 12823 marked, exterior grade (grade l type ll), having one side decorative lamination and other side balancing lamination, including iind class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the engineer-in-charge 93 providing and fixing aluminum u beading of required size to pre-laminated/flush door shutter, including fixing etc. complete as per direction of engineer-in-charge. 94 providing and fixing casement handle made of zinc alloyed (white powder coated) for upvc casement window with necessary screws etc. complete. 95 providing and fixing zinc alloyed (white powder coated) touch lock for upvc sliding window with necessary screws etc. complete. 96 providing and fixing steel roller for upvc sliding window with necessary screws etc. complete. 97 providing and fixing steel roller for upvc sliding door with necessary screws etc. complete. 98 providing and fixing steel (white power coated) crescent lock for upvc sliding window/ door with necessary screws etc. complete. 99 providing and fixing 18mm thick both sides pre-laminated cement bonded wood particle board as per is : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of engineer-in-charge (note: fittings to be paid separately). 100 providing and fixing 6mm thick both sides pre-laminated cement bonded wood particle board as per is : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of engineer-in-charge. 101 providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed bwp grade marine ply as per is 710 of approved brand including 2mm thick pvc edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of engineer-in-charge.(payment of providing and fixing auto closing hinges shall be paid separately) 102 structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 103 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of t-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 104 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.(using m.s. angels 40x40x6 mm for diagonal braces) 105 providing and fixing stainless steel ( grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 106 providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of engineer-in-charge. 107 brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar with 1:6 (1cement : 6 coarse sand) including filling the joints with same mortar, with common burnt clay non modular bricks: 108 dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with jamuna sand, with common burnt clay non modular bricks. 109 40 mm thick with 20 mm nominal size stone aggregate cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 110 18 mm thick cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 111 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 112 cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. 113 25 mm thick kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 114 deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. 115 fixing glazed/ ceramic/ vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (water based) conforming to is: 15477, in average 3mm thickness. 116 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 117 providing and fixing 1st quality ceramic glazed floor tiles conforming to is : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 118 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to is : 15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 119 providing and laying vitrified floor tiles size 600x600 mm(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. 120 providing 1 mm thick with zinc coating not less than 275 gm/ m² corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 121 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 122 providing & fixing 0.56 mm, aluminium color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm at all heights, levels and locations colour finish aluminium alloy roofing sheets of alloyis designation31500, temper hx8 conforming to is 737 and dimensions as per is code 2676 with characteristics of good formability and corrosion resistance. the profile sheets shall be fixed to truss members in slope or required pitch or curvature with hex cap headed self drilling/tapping stainless steel screws m6, 50 mm long with 3 mm epdm seal washer etc. all inclusive of labour, scaffolding, t&p and sundries etc. complete as per directions of the engineer-in-charge. (cost of truss/frame work shall be paid separately). 123 providing and fixing precoated/mill finish aluminium ridges plain (500- 600mm) of pre-coated colour or mill finishaluminium roofing accessories in 0.71 mm thickness ,alloy 31500 (is designation) [aluminium alloy (aa) 3004 (iso designation)]for color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping ss screws of size 6 x 50mm with 3mm thick epdm seal and ss plain washer complete : 124 providing 10 mm thick plaster of paris (gypsum anhydrous) flat surfaces ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 125 12.5 mm thick fully perforated gypsum board tile made from plasterboard having glass fibre conforming to is: 2095 part i, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an nrc (noise reduction coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 126 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) 127 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) 128 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) 129 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) 130 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 131 neat cement punning. 132 distempering with 1st quality acrylic distemper (ready mixed) new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than50 gram/litre of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 133 finishing walls for new work (two or more coats applied @ 3.84 kg/10 sqm) with water proofing cement paint of required shade : 134 finishing walls for new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) with acrylic smooth exterior paint of required shade : 135 finishing walls for new work (two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. with ready mixed premium acrylic emulsion paint (company depot tinted) having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. 136 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 137 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 138 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) 139 painting (two or more coats) on 100mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 140 painting (two or more coats) on 150mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 141 painting two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 142 polishing on new wood work with ready mixed wax polish of approved brand and manufacture : 143 lettering with black japan paint of approved brand and manufacture 144 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 145 distempering for old work (one or more coats) with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour 146 applying priming coats with water thinnable cement primer on wall surface having voc content less than 50 grams/litre of approved brand and manufacture. 147 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of engineer-in-charge. 148 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 149 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 150 polishing on old wood work with ready made wax polish of approved brand and manufacture : 151 painting (one or more coats) with black japan paint of approved brand and manufacture to give an even shade. 152 finishing walls for old work (two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface with acrylic smooth exterior paint of required shade : 153 repairs to plaster of thickness 12 mm to 20 mm with cement mortar 1:4 (1 cement : 4 fine sand) in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge. 154 fixing door chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge. 155 fixing chowkhat in existing opening in brick/ rcc wall with dash fasteners/chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including cost of dash fasteners/ chemical fastener. 156 making the opening for door/ window/ clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of engineer-in-charge. 157 renewing float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) with putty and nails wherever necessary including racking out the old putty: 158 renewing float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) with putty and nails wherever necessary including racking out the old putty: 159 renewal of old putty of glass panes (length) 160 refixing old glass panes with putty and nails 161 fixing old glass panes with wooden fillets (excluding cost of fillets) 162 renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 163 pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 164 providing and fixing 20 mm diameter. brass curtain rods ofwall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 165 repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of engineer-in-charge. 166 cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of engineer-in-charge. 167 disconnecting damaged overhead/terrace pvc water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of engineer-in-charge. 168 providing & fixing orissa pattern w.c pan of size 580x440 mm white vitreous china water closet squatting pan (indian type) along withs or p trap including dismantling of old wc seat and s or p trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of engineer-in charge. 169 dismantlingw.c.pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in-charge. 170 dismantling 15 to 40 mm dia g.i. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of engineer-in-charge.(a) internal work- exposed on wall 171 taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the engineer-in-charge. 172 demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of engineer- in-charge. 173 demolishing nominal cementconcrete 1:3:6 or richer mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 174 demolishing nominal cementconcrete 1:4:8 or leaner mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 175 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer - in- charge. 176 demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 177 removing mortar from bricks in from brick work in cement mortar and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): 178 dismantling doors, windows and clerestory windows (steel or wood) shutter of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 179 dismantling doors, windows and clerestory windows (steel or wood) shutter of area beyond 3 sq. metres including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 180 taking out doors, windows and clerestory window shutters (steel or wood) of area 3 sq. metres and belowincluding stacking within 50 metres lead : 181 taking out doors, windows and clerestory window shutters (steel or wood) of area beyond 3 sq. metres including stacking within 50 metres lead : 182 dismantling for thickness of tiles 10 mm to 25 mmwork in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 183 dismantling for thickness of tiles above 25 mm and up to 40 mmwork in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 184 demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : 185 dismantling g.s. sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 metres lead of: 186 dismantling asbestos cement sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 metres lead of: 187 dismantling tiled roofing with battens, boarding etc. complete includingstackingofserviceablematerialanddisposalofunserviceable material within 50 metres lead. 188 dismantlingbarbedwireorflexiblewireropeinfencingincludingmaking rolls and stacking within 50 metres lead. 189 dismantling40 mm thick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 metres lead : 190 dismantling40 mm to 75mmthick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 metres lead : 191 dismantling cement asbestos or other hard board ceiling or partition wallsincludingstackingofserviceablematerialsanddisposalof unserviceable materials within 50 metres lead. 192 dismantling of flushing cistern of all types(c.i./pvc/vitrious china) includingstackingofusefulmaterialsnearthesiteanddisposalofunserviceable materials within 50 metres lead. 193 dismantling old plaster or skirting raking out joints and cleaning the surfaceforplasterincludingdisposalofrubbishtothedumping ground within 50 metres lead. 194 dismantlingaluminium/gypsumpartitions,doors,windows,fixed glazing and false ceiling including disposal of unserviceable material andstackingofserviceablematerialwithin50metersleadas directed by engineer-in-charge. 195 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping groundorasapprovedbyengineer-in-charge,beyond50minitial lead, for all leads including all lifts involved. 196 cuttingroadandmakinggoodthesameincludingsupplyofextra quantities of materials i.e. aggregate, moorum screening, red bajri and labour (required.bituminous portion) 197 paintingroadsurfacemarking for new work (two or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to is : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 198 paintingroadsurfacemarking for old work (one or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to is : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 199 taking out existing cc interlocking paver blocks from footpath/ central verge,includingremovalofrubbishetc.,disposalofunserviceable materialtothedumpingground,forwhichpaymentshallbemade separately and stackingof serviceable materialwithin 50metre lead as per direction of engineer-in-charge. 200 layingoldcementcocreteinterlockingpaverblocksofanydesign/ shapelaidinrequiredline,level,curvature,colourandpatternover and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer- in-charge. (old cc paver blocks shall be supplied by the department free of cost). 201 providing and laying 80mmthickc.c.paverblockofm-35gradewith approved colour design and pattern.factory made chamfered edge cement concrete paverblocksinfootpath,parks,lawns,drivewaysorlighttraffic parkingetc,ofrequiredstrength,thickness&size/shape,madeby tablevibratorymethodusingpumould,laidinrequiredcolour& patternover50mmthickcompactedbedof sand,compactingand properembedding/layingofinterlockingpaverblocksintothesand beddinglayerthroughvibratorycompactionbyusingplatevibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. completeall as per direction of engineer-in-charge. 202 providing andfixingwhitevitreouschinaorissapatternw.c.panofsize 580x440 mm with integral type foot rests waterclosetsquatting pan(indian typew.c. pan)with100mmsandcastironporstrap,10litrelowlevel whitep.v.c.flushingcistern,includingflushpipe,withmanually controlleddevice(handlelever)conformingtois:7231,withall fittingsandfixturescomplete,includingcuttingandmakinggood the walls and floors wherever required: 203 providing and fixing w.c. pan with isi marked white solid plastic seat and lid white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard makeandmosquitoproofcouplingofapprovedmunicipaldesign complete,includingpaintingoffittingsandbrackets,cuttingand making good the walls and floors wherever required : 204 providingandfixing oneurinalbasinwith5litrewhitep.v.c.automaticflushing cistern whitevitreouschinaflatbackorwallcorner typelippedfronturinalbasinof430x260x350mmand 340x410x265 mm sizes respectively with automatic flushing cistern withstandardflushpipeandc.p.brassspreaderswithbrass unions and g.i clamps complete, including painting of fittings and brackets,cuttingandmakinggoodthewallsandfloorswhereverrequired : 205 providingandfixingwhitevitreouschinawashbasinsize550x400mm with a pair of 15 mm c.p. brass pillar taps washbasinwithc.i.brackets,15mmc.p. brasspillartaps,32mmc.p.brasswasteofstandardpattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 206 providing and fixing wash basin with c.i. brackets, 15 mm dia cp brasssingleholebasinmixerofapprovedqualityandmake, including painting of fittings and brackets, cutting and making goodthe walls wherever required:- (a)white vitreous china wash basin size 550x400 mm with a 15 mm cp brass single hole basin mixer 207 providingandfixingwhitevitreouschinapedestalforwashbasin completelyrecessedatthebackforthereceptionofpipesand fittings. 208 providing and fixing 610x510 mm bowl depth 200 mm stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (kitchen sink without drain board) 209 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer - in - charge. 210 providing and fixing 10 litre capacity - white p.v.c. low level flushing cistern with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete. 211 providing and fixing 10 litre (full flush) capacity-white controlled flush, low level cistern made of vitreous china with all fittings complete. 212 providing and fixing g.i. inlet connection for flush pipe connecting with w.c. pan. 213 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer-in-charge. 214 providing and fixing15 mm nominal dia cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge. 215 providingandfixing 32mm diaflexible pipe p.v.c.wastepipeforsinkorwashbasin including p.v.c. waste fittings complete. 216 providing and fixing 100 mm sand cast iron grating for gully trap. 217 providingandfixinginposition25mmdiametermosquitoproofcoupling of approved municipal design. 218 providing and fixing 600x450 mm beveled edge mirror of superior glass(ofapprovedquality)completewith6mmthickhardboard ground fixed to wooden cleats with c.p. brass screws and washerscomplete. 219 providing andfixing circular shape 450 mm dia mirrorofsuperiorglass(ofapprovedquality)andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : 220 providing andfixing 600x120x5 mmglass shelfwith edges round off, supported on anodised aluminium angle frame with c.p. brass bracketsandguardrailcompletefixedwith40mmlongscrews, rawl plugs etc., complete. 221 providing and fixing c.p. brass toilet paper holder : 222 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 223 providing and fixing ptmt towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 224 providing and fixing ptmt 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 225 providing and fixing ptmt 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 226 providing and fixing ptmt shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. 227 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 228 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 229 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 230 providing and fixing 25 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 231 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 232 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 233 providing and fixing 25 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 234 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 235 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 236 providing and fixing 25mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 237 providing and fixing 32mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 238 providing and fixing 40mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 239 providing and fixing 50mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 240 providing and fixing 15 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 241 providing and fixing 20 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 242 providing and fixing 25 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 243 providing and fixing 15 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 244 providing and fixing 20 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 245 providing and fixing 25 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 246 providing and fixing 32 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 247 providing and fixing 40 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 248 providing and fixing 50 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 249 providing and fixing 25 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 250 providing and fixing 20 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 251 providing and fixing 32 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 252 providing and fixing 15 mm nominal bore ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 253 providing and fixing 20 mm nominal bore ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 254 providing and fixing 15mm norminal bore 45 cm length uplasticised pvc connection pipe with brass unions : 255 providing and fixing 20mm norminal bore 45 cm length uplasticised pvc connection pipe with brass unions : 256 providing and fixing 100 mm diameter c.p. brass shower rose with 15 or 20 mm inlet : 257 providing and fixing 150 mm diameter c.p. brass shower rose with 15 or 20 mm inlet : 258 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 259 providing and fixing 15 mm nominal bore c.p. brass bib cock of approved quality conforming to is:8931 : 260 providing and fixing 15 mm nominal bore c.p. brass long nose bib cock of approved quality conforming to is standards and weighing not less than 810 gms. 261 providing and fixing 15 mm nominal bore c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 262 providing and fixing 15mm nominal bore c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 263 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 264 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 265 providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to is: 1868, minimum anodic coating of grade ac 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer-in-charge. (glazing, paneling and dash fastenersto be paid for separately) :(for fixed portion) 266 providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer-in-charge. (glazing, paneling and dash fastenersto be paid for separately) :(for fixed portion) 267 providing and fixing glazing with float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 268 providing and fixing glazing with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 269 providing and fixing glazing with float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 270 providing and fixing with stainless steel cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to is : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer-in-charge. 271 providing and fixing with brass cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to is : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer-in-charge. 272 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours.(b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 273 providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of fibre glass cloth when the first layer is still green. overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. this will be allowed to air cure for 4 hours followed by water curing for 48 hours. the entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (for the purpose of measurement the entire treated surface will be measured.) 274 providing & applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of engineer-in-charge. 275 providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of rcc structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. after cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. over the primed surface swellable type water stop tape shall be placed. the work shall be carried out all complete as per specification and the direction of the engineer-in-charge. the product performance shall carry guarantee for 10 years against any leakage. 276 providing and fixing with15mmthick fullyperforatedsquare/buttedgelightweightcalcium silicate panels/ tiles in position wall panelling at all heights with integral densified calcium silicatepanels/tilesofsize595x595mm,havingnrc(noisereductioncoefficient)of0.50 (minimum) as per is 8225:1987, light reflectance of 85% (minimum). non combustible as per bs:476 (part-4), fire performance as per bs:476 (part 6 &7), humidity resistanceof 100%,thermalconductivity<0.043w/mk asperastm518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mmthickpressedsection(galvanizing@120gramspersqmincludingbothsides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor andceilingchannel sectionofsize50x32mfixedtothefloorandsoffitat600mm centersusing12mmdia,50mmlongwedgetypeexpandedzincalloy dashfastnerwith 10mm bolt. this same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. glasswool of 50mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to bescrew fixed withselftapping panheadnickel coatedmild steelscrewsofsize13x3.2mmon tothisgridleavingan evengroove of1 mm betweenthepanels. the joints betweenthepanelsaretobedulyjointedandfinishedusingrecommendedjointing calcium silicate based compound and fiber joint tape roll 50mm wide(90 metre )roll and twocoatsofprimersuitableforpanellingaspermanufacturersspecificationasper direction of engineer-in-charge all complete. 277 providing and fixing with 16 mm thick beveled tegular mineral fibre false ceiling tile (nrc 0.55 to 0.6 mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%,lightreflectance=85%,thermalconductivityk=0.052-0.057w/mk,fire performance as per (bs 476 pt - 6 &7)in true horizontal level suspended on interlocking t- grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm)comprisingofmaintrunnersof15x32mmoflength3000mm,crosstofsize 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length600mm toform gridmoduleofsize 600x600mm suspendedfrom ceiling using galvanizedmildsteelitem(galvanised@80gsm)50mmlong8mmouterdiameterm-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l- shapeleveladjusterofsize85x25x2mm,spacedat1200mmcentretocentrealong main‘t’.thesystemshouldrestonperipherywalls/partitionswiththehelpofgi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry walls.s. screws. the exposed bottom portion of all t-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. the work shall be carriedoutasperspecifications,drawingsandasperdirectionsoftheengineer-in- charge. 278 providingandfixingharddrawnsteelwirefabricofsize75x25mmmeshorother suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of l shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge. 279 fillingofjointsbetweenrccplinthbeam/floorslabandwallpanelofexternalwalls, toilet / bath room / wet areas walls on all floor and parapet wall over roof slab, stair case headroomatthetimeoferectionofgfrgpanelswithgroutrw/equivalentsealant compound after the erection of panelbeforethe infill of concrete in panel cavities and fine finish. this applies for all horizontal and vertical joints between gfrg wall and slab panels. 280 waterproofingtreatmentofverticaljoints(ofexternalsideandinternalside)between doorframe,window&ventilatorframes(onallfoursides)ofouterwalloverthe zycosil/equivalent & zycoprime/equivalent solution already applied (before the installation of door / window / ventilator frames in position) and fine finish with grout rw/equivalent. 281 waterproofingtreatmentofrccsunshadewith zycosil/equivalentwaterproofing solution(1litreofzycosil/equivalent&20litresofwaterstirredfirst&2litresof zycoprime/equivalent addedandstirred (total23litres))till itmeetsthesaturationlevel and testing as per rilem or bywater drops test in which water drops do not absorb but drops remain or rolls. 282 in-filling / sealing of joint between rcc lintel cum sunshade and wall (on external side) in all floors by pushing in grout rw/equivalentin paste form and coving 20 mm x 20 mm after applying a coat of zycosil/equivalent & zycoprime/equivalent solution before cement plastering of top, bottom and sides of rcc sunshade. 283 concreteworkwith40mmgaugebrickballastobtainedfrombreaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in csi no. 5.01 includingcost of all labour, materials, t&p etc required for proper completion of work. 284 brickworkinfoundation&plinthwitholddismantled bricks(suppliedby departmentfreeofcost)andcoarsesand mortarin1:6includingsupply ofallothermaterials,labour,removingmortar&cleaningofold&usedbricks,t&p etc complete. 285 supply and filling brick bat in soak pit including all labour,material and t&petc complete. (for 01 soak pit) 286 supplying & fixing 24 gauge annodized aluminium sheet of approved qualityincludingcutting,wastageandfixingthesameoverthewooden door shutters with nails with all material, labour and t&p 287 providingandfixinginplaceafullheightstoragecabinet450mmdeep made with19 mm thick isi marked plyborad, allinterior surfaces to finishedwithpastingof0.8mmthickmicaandallexteriorsurfacestobe finshed with pasting of 1 mm thick mica of texture and colour as approved byengineerinchargeincludingalllabour,t&p,otheritemslike(butnot limitedto)fevicol,nailsscrews,higes,sliders,doorhandles,multipurpose lockofgodrejorequivalentrateetc.requiredforpropercompletionof works, to be measured interms of front area only. 288 providingandfixingfullheightpartitionwith02nos12mmthickisi marked ply board, all surfaces to finished withf 1 mm thick mica of texture andcolourasapprovedbyengineerinchargeandfixedinpolishedteak woodincludingalllabour,t&p,otheritemslike (butnot limitedto) fevicol, nailsscrews,hinges,sliders,doorhandles,multipurposelockofgodrejor equivalent rate etc. required for proper completion of works, to be measured interms of front area only 289 providingandfixing12mmthickframelesstoughenedglassdoorshutter ofapprovedbrandandmanufacture,includingprovidingandfixingtop& bottom pivot & double acting hydraulic floor spring type fixing arrangement ,doorhandle,lockandstopperetcandmakingnecessaryholesetc.for fixingrequireddoorfittings,allcompleteasperdirectionofengineer-in- charge 290 supply and fixing 6mm thick polycarbonate multiwall sheet ,fixing in position with j or u bolts 10 mm. dia with g.i. limpet & bitumen washers including supply of all materials, labour,wastage. and t&p etc. required for proper completion of the work. 291 providing (12x15) mm section groove in plasterincluding all material, labour andt&p etc. required for proper completion of the work.csi no.11.16 292 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cccsi no.12.26 293 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cc csi no. 12.28 294 dismantling ofdry b.o.e. floor and proper stacking of dismantled bricks as per direction of e/c. up to 60 m lead. 295 dismantling and re-laying of dry b.o.e. floor including cost of all labour and t&p required forproper completion of work.(labour rates only) 296 cleaning panes of glass with spirit of caustic soda including supply of all materials,labour and t&p etc.required for proper completion of the work. 297 cleaning of septic tank including disposal of waste out side the uppcl area as per direction of the engineer-in-charge including cost of all labour,t&p etc.required for proper completion of the work. 298 cleaning and opening of chocked w.c./ bath / kithchen pipe line including opening and refixing of chamber cover including washing etc. complete.(analysis based on nbo - 11 25.020. 299 s/laying chicken mesh of (20 mm.)hexagonal heavy quality over roofs of joints of roof as per direction of the engineer - in - charge. 300 cleaning of existing pipe line of different dia. ranging from 4 to 2 dia. including digging trenches and refilling, opening of pipes, cleaning of pipes, cutting, threading, if required fixing and including making good the road, wall etc as directed by the engineer i/c. 301 cleaning of existing water pipe line of different dia up to 2 dia including digging trenches and refilling,opening and cleaning of pipes,cutting,threading,if required fixing and including making good the road and wall etc. as directed by the engineer in charge. 302 cleaning of r.c.c. over head tank up to capacity of one lac. liters and chlorinating with bleaching power mixed to water as per direction of engineer - in - charge complete. 303 supply and mixing bleaching powder in over head tank as required or as directed by engineer - in - charge. 304 attending to petty maintenance service like plumbingservice,welder service, mansion service and carpenter servicerequired as below. (job attending by one no. plumber/welder/mason /carpenter with oneno. helper per hour or part of an hour.) 305 cleaning and sweeping of roof of residence as and when requiredincluding uprooting of rank vegetation and disposal of thegarbage upto 50 m. 306 providing and fixing of 150 mm dia pvc pipeof 6 kg/sqcmwith special such as tee, bend, socket, elbow etc including supply of all labour,material,t & p etc complete required for proper completion of work. 307 providing and laying 75 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 308 providing and laying 90 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 309 providing and laying 110 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 310 making arrangement for sweeping, cleaning of road, lanes in back of houses,collecting refuse of bushes & unwanted plants, vegetations etc. & disposal of all rubbish, materials industbins inside the colony area with engaging atleast one number of sweepers including all labour, t&p,etc.required for completion of work as directed by e/i. 311 making arrangement for sweeping, cleaning of ee,ecd(d), georgetown ,prayagraj office rooms, cleaning of dustbin, toilets , dusting of almirahs,tables etc. using phenyle,dusting cloth etc. and disposal of waste outside office premise in municipal dustbinswith engaging sufficient number ofsweepersincluding all labour, t&p,etc.required for completion of work as directed by e/i.(nsi)(consumable items as phenyle,dusting cloth ,brooms etc shall be provided by the department free of cost.) 312 cleaning of main drain or width more than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the e/i. including cost of all labour, t&p etc. required for completion of the work. (csino.20.14) 313 cleaning of main drain or width less than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the e/i. including cost of all labour, t&p etc. required for completion of the work. (csino.20.15) nsi sl. no.63 314 operation of tube well daily by a suitable experienced operator continously or in different intervals as per program as per program fixed by engineer-in-charge including opening and closing of valves,changing of fuse wire etc. as requrird for proper running of tube well. (nsi) 315 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required..group c 316 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet 317 supplying and fixing of 20 mm of medium class pvc conduit along with accessories in surface/recess including junction box, cutting the wall and making good the same in case of recessed conduit as required. 318 supplying and fixing of 25 mm of medium class pvc conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required. 319 wiring for circuit/ submain wiring with 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 320 wiring for circuit/ submain wiring with 2 x 4 sq. mm + 1 x 4 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 321 wiring for circuit/ submain wiring with2 x 6 sq. mm + 1 x 6 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 322 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required . 323 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 324 supplying and fixing 5 amps to 32 amps rating,single pole, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 325 supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 326 supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 327 supplying and fixing 4 way (4 + 12), double door, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 328 supplying and fixing of 4 way (4 + 12), double door surface/ recess mounting, vertical type, 415 volts, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally used where 3 phase outlets are required.) 329 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit along with 1 no 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 330 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (75mmx75mm) 331 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required.3 module (100mmx75mm) 332 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 4 module (125mmx75mm) 333 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 6 module (200mmx75mm) 334 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 8 module (125mmx125mm) 335 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 12 module (200mmx150mm) 336 supplying and drawing following 3 x 2.5 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 337 supplying and drawing following 3 x 4 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.(dsr e&m 2022 1.17.21) 338 rewinding of burnt ceiling fan with approved copper wire including cost of all materials, labour and t&p etc. complete (burnt wirewill not be taken back.) 339 greasing of ceiling fan after cleaning the bearing and shaft withoil / petrol and its testing. 340 supply and fixing of led tube light batten fitting suitable for up to 1 x 22 watt led tube light on surface complete in all respect.(csi no. 28.41) 341 supply of 9 watt led bulb make philips, syska, bajaj etc or its equivalent as directed by e/i. 342 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min, 350 rpm (tolerance as per is: 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required.(dsr e&m 2022 19.1) 343 supply and fixing of 5 blade exhaust fan ventile air dx 225 mm of havellsor equivalent make including all material, t&p etc required for proper completion of work as approved by engineer in charge.(csi no. 28.38) 344 supply and fixing of 3 blade wall fan ofhavells platina 400 mm or equivalent including all material, t&petc required for proper completion of work as approved by engineer in charge.(csi no. 28.37)
  • View Tender
  • Document
  • Bid Support
9 Housing Urban And Rular Development
image image
Government Departments
TRN :49056962 |  29 May, 2025
Tender Value : 5.80 Crore
 Gaya - Bihar
Tender for tender for special repair work at jnv gaya-i (bihar) - school building 2 structural repair & retrofitting 3 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 4 50mm average thickness 5 25 mm average thickness 6 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 7 bars upto 12 mm diameter 8 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 9 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 10 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in grade m 25 with cement content not less than 330 kg per cum 12 50mm thick in grade m 25 with cement content not less than 330 kg per cum 13 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 14 expansion joint treatment 15 providing and fixing of expansion joint system related with floor location as per drawings and direction of engineer-in-charge. the joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per astm b221-02. the system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. system shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. the cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. the self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. provision of moisture barrier membrane in the joint system to have watertight joint is mandatory requirement all as per the manufactures design and as approved by engineer -in- charge. (material shall confirm to astm 6063). 16 floor joint of 100 mm gap 17 providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of engineer-in- charge. the joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per astm b221- 02. the material shall be such that it provides an expansion joints systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office buildings & complexes with no slipping down tendency amongst the components of the joint system. the joint system shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (material shall confirm to astm 6063). 18 wall joint of 100 mm gap 19 providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of engineer-in-charge. the joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per astm b221-02. the system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. system shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. the cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. the self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. the joint system shall resists damage or deterioration from the impact of falling ice, exposure to uv, airborne contaminants and occasional foot traffic from maintenance personnel. provision of moisture barrier membrane in the joint system to have water tight joint is mandatory requirement. (material shall confirm to astm 6063.) 20 roof joint of 100 mm gap 21 repairs to roof 22 repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (dr. fixit make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge.with cement mortar 1:4 (1 cement: 4 coarse sand) 23 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 24 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 25 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 26 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 27 asbestos cement sheet 28 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 29 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 30 repair to toilets + plumbing works 31 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 32 for thickness of tiles 10 mm to 25 mm 33 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 34 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 35 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 36 providing and filling of cinder in sunken portion. 37 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 38 75 to 80 mm dia pipe 39 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 40 15 mm to 40 mm nominal bore 41 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 42 up to 150 mm diameter 43 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 44 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 45 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 46 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 47 rectangular manhole 90x80 cm and 45 cm deep 48 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 49 110 mm diameter 50 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 51 a) coupler 52 110 mm 53 b) bend 87.5° 54 110 mm bend 55 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 56 75 mm diameter pipes 57 100 mm diameter pipes 58 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 59 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 60 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 61 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 62 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 63 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 64 a) 32mm dia (for wash basin) 65 b) 40mm dia (for sink and urinal) 66 providing & fixing c.p. brass waste coupling for pvc waste pipe. 67 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 68 110 mm dia (wall thickness - 3.2 to 3.8 mm) 69 75 mm dia (wall thickness - 3.2 to 3.8 mm) 70 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 71 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 72 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 73 p-trap type floor trap 110 x 75 mm 74 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 75 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 76 providing and fixing 100 mm sand cast iron grating for gully trap. 77 providing & fixing soil, waste and vent pipes. 78 a) 100mm dia centrifugally cast iron s & s pipe. 79 b)75mm dia centrifugally cast iron s & s pipe. 80 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 81 a) for 100mm dia pipe. 82 b) for 75mm dia pipe. 83 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 84 a) 100mm 85 sand cast iron s&s as per is - 3989 86 b) 75mm 87 sand cast iron s&s as per is- 3989 88 providing and fixing plaincast iron s & s sanitary bend. 89 a) 100mm 90 sand cast iron s&s as per is - 1729 91 b) 75mm 92 sand cast iron s&s as per is - 3989 93 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 94 a) 100x100x100mm 95 b) 75x75x75mm 96 providing and fixingcast iron terminal guard. 97 a) 100mm 98 b) 75mm 99 providing & fixingcast iron coller. 100 a)100 mm 101 sand cast iron s&s as per is - 3989 102 b)75mm dia. 103 sand cast iron s&s as per is - 3989 104 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 105 a) 100mm 106 b) 75mm 107 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 108 a) 100mm inlet & 75mm outlet. 109 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 110 providing and fixing ptmt urinal cock of approved quality and colour. 111 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 112 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 113 15 mm nominal outer dia pipes 114 20 mm nominal outer dia pipes 115 25 mm nominal outer dia pipes 116 32 mm nominal outer dia pipes 117 providing and fixing brass stop cock of approved quality. 118 15 mm nominal bore 119 providing and fixing gun metal gate valve with wheel of approved quality. 120 a) 25mm dia nominal bore 121 b) 32mm dia nominal bore 122 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 123 a) 25mm. nominal bore 124 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 125 a) 15mm nominal bore 126 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 127 a) 15mm nominal bore 128 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 129 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 130 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 131 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 132 providing & fixing cp brass bib cock of approved quality conforming to is 8931 133 a) 15mm nominal bore 134 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 135 a) 15mm nominal bore 136 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 137 15mm nominal bore 138 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 139 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 140 25mm nominal bore, weighing not less than 62 gms 141 cutting holes up to 30x30 cm in walls including making good the same: 142 with common burnt clay f.p.s. (non modular) bricks 143 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 144 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 145 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 146 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 147 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 148 repair to plaster and plinth protection 149 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge.nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 150 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 151 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 152 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 153 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 154 with cement mortar 1:4 (1cement: 4 coarse sand) 155 12mm cement plaster of mix : 156 1:6 (1 cement : 6 course sand) 157 6mm cement plaster to ceiling of mix : 158 1:3 ( 1 cement : 3 fine sand) 159 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 160 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 161 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 162 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 163 old work (one or more coats) 164 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 165 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 166 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 167 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 168 repairs to door / windows 169 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 170 of area 3 sq. metres and below 171 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 172 of area 3 sq. metres and below 173 renewing glass panes, with putty and nails wherever necessary including racking out the old putty:float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 174 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 175 35 mm thick including isi marked stainless steel butt hinges with necessary screws 176 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 177 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete 178 fixed to steel windows by welding 179 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 180 300 mm weighing not less than 200gms. 181 250 mm weighing not less than 150gms. 182 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 183 100x58x1.90 mm 184 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 185 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 186 300 x 10mm 187 200 x 10mm 188 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 189 125 mm 190 providing and fixing factory made pvc door shutter made of solid foam pvc profiles of thickness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top / bottom / lock) rails of minimum cross section of 70mm x 28mm, of shape and design as per manufacturers specifications having homogenous fine cellular structure and smooth integral outer skin, inserted with g.l. c section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stiffeners as per manufacturers specifications mitered cut joints for styles and rails provided with telescopic polymeric l corners are joined together using solvent adhesive and strengthened with fully threaded stainless steel screws (of required size) through reinforcement stiffener with paneling of specified solid foam pvc board / high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam pvc moulded headings of required size using pvc solvent adhesive / cement. the finished door shutter including ss hardware, 1 no. ss sliding door bolt 200 x 10mm, 1 no. ss tower bolt 200 x 10mm and 2 nos. ss handles 125 mm, shall be fixed to frame with 3 nos. stainless steel hinges of minimum size 100x58x1.9mm and stainless steel screws of required size complete as per direction of the engineer-in-charge.(cost of above hardware is inclusive in rates) 5 mm thick solid foam pvc panel of required size with moulded/extruded beading of appropriate design shape and size as per manufacturers specifications (to secure the panel insert tight in place within the style and rails of the shutter)matching the color &shade of shutter frame - non decorative type. 191 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 192 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 193 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 194 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 195 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 196 4.0 mm thick glass panes 197 applying priming coat : 198 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 199 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 200 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 201 two or more coats on new work 202 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 203 one or more coats on old work 204 repairs to flooring 205 miscellaneous 206 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 207 in cement mortar 208 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 209 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) : 3 graded stone aggregate 20 mm nominal size). 210 centering and shuttering including strutting, propping etc. and removal of form for all heights : 211 edges of slabs and breaks in floors and walls 212 under 20 cm wide 213 centering and shuttering including strutting, propping etc. and removal of form for all heights : 214 suspended floors, roofs, landings, balconies and access platform. 215 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 216 thermo-mechanically treated bars of grade fe-500d or more. 217 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 218 cement mortar 1:6 (1 cement : 6 coarse sand) 219 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 220 cement mortar 1:4 (1 cement :4 coarse sand 221 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 222 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 223 electrical work of school building 224 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 225 group c 226 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 227 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 228 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 229 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 230 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 231 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 232 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 233 group c 234 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 235 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 236 2 x 1.5 sq. mm 237 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 32 mm 240 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 241 100 mm x 100 mm x 60 mm deep 242 150 mm x 75 mm x 60 mm deep 243 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 244 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 245 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 246 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 247 supplying and fixing brass batten/ angle holder including connection etc. as required. 248 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 249 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 250 6 way, double door 251 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 252 4 way (4 + 12), double door 253 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 254 single pole 255 single pole and neutral 256 triple pole 257 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 258 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 259 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 260 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/ coke and salt as required. 261 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 262 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 263 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 264 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 265 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 266 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover 3on the fan box etc. as required. 267 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 268 upto 450 mm sweep 269 supply of 15w surface mounted round led with all accessories as per standard item.. 270 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 271 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 272 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 273 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 274 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 275 450 mm sweep 1400 rpm 276 lightning conductor 277 providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, g.i. tube, having single prong at top, with 85 mm dia 6 mm thick g.i. base plate including holes etc. complete as required. 278 fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 279 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 280 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 281 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 282 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 283 providing and fixing testing joint, made of 20 mm x 3 mm thick g.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chuck nuts and spring washers etc. complete as required. 284 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. details of cost for one set 285 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 286 bill of quantity for boys dinning hall 287 repairs to roof 288 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 289 asbestos cement sheet 290 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 291 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 292 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 293 repair to plaster and plinth protection 294 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 295 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 296 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 297 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 298 with cement mortar 1:4 (1cement: 4 coarse sand) 299 12mm cement plaster of mix : 300 1:6 (1 cement : 6 course sand) 301 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 302 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 303 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 304 old work (one or more coats) 305 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 306 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 307 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 308 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 309 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 310 repairs to door / windows 311 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 312 of area 3 sq. metres and below 313 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 314 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 315 renewal of old putty of glass panes (length) 316 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 317 35 mm thick including isi marked stainless steel butt hinges with necessary screws 318 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 319 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 320 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 321 300 mm weighing not less than 200gms. 322 250 mm weighing not less than 150gms. 323 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 324 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 325 300 x 10mm 326 150 x 10mm 327 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 328 with 12 mm mild steel u beading 329 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 330 125 mm 331 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 332 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 333 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 334 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 335 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 336 4.0 mm thick glass panes 337 applying priming coat : 338 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 339 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 340 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 341 two or more coats on new work 342 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 343 one or more coats on old work 344 flooring 345 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 346 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 347 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 348 25 mm thick 349 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 350 miscellaneous 351 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 352 in cement mortar 353 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 354 cement mortar 1:6 (1 cement : 6 coarse sand) 355 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 356 75 to 80 mm dia pipe 357 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 358 110 mm diameter 359 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 360 a) coupler 361 110 mm 362 b) bend 87.5° 363 110 mm bend 364 kitchen & dinning 365 structural repair & retrofitting 366 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 367 50mm average thickness 368 25 mm average thickness 369 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 370 bars upto 12 mm diameter 371 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 372 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 373 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 374 25mm thick in grade m 25 with cement content not less than 330 kg per cum 375 50mm thick in grade m 25 with cement content not less than 330 kg per cum 376 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 377 repairs to roof 378 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 379 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 380 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 381 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 382 asbestos cement sheet 383 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 384 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 385 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 386 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 387 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 388 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.electric resistance or induction butt welded tubes. 389 repair to toilets + plumbing works 390 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 391 for thickness of tiles 10 mm to 25 mm 392 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 393 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 394 plumbing work 395 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 396 75 to 80 mm dia pipe 397 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 398 15 mm to 40 mm nominal bore 399 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 400 up to 150 mm diameter 401 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 402 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 403 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 404 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 405 rectangular manhole 90x80 cm and 45 cm deep 406 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 407 110 mm diameter 408 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 409 a) coupler 410 110 mm 411 b) bend 87.5° 412 110 mm bend 413 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 414 75 mm diameter pipes 415 100 mm diameter pipes 416 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 417 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 418 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 419 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 420 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 421 a) 32mm dia (for wash basin) 422 b) 40mm dia (for sink and urinal) 423 providing & fixing c.p. brass waste coupling for pvc waste pipe. 424 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 425 110 mm dia (wall thickness - 3.2 to 3.8 mm) 426 75 mm dia (wall thickness - 3.2 to 3.8 mm) 427 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 428 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 429 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 430 p-trap type floor trap 110 x 75 mm 431 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 432 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 433 providing and fixing 100 mm sand cast iron grating for gully trap. 434 providing & fixing soil, waste and vent pipes. 435 a) 100mm dia centrifugally cast iron s & s pipe. 436 b)75mm dia centrifugally cast iron s & s pipe. 437 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 438 a) for 100mm dia pipe. 439 b) for 75mm dia pipe. 440 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 441 a) 100mm 442 sand cast iron s&s as per is - 3989 443 b) 75mm 444 sand cast iron s&s as per is- 3989 445 providing and fixing plaincast iron s & s sanitary bend. 446 a) 100mm 447 sand cast iron s&s as per is - 1729 448 b) 75mm 449 sand cast iron s&s as per is - 3989 450 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 451 a) 100x100x100mm 452 b) 75x75x75mm 453 providing and fixingcast iron terminal guard. 454 a) 100mm 455 b) 75mm 456 providing & fixingcast iron coller. 457 a)100 mm 458 sand cast iron s&s as per is - 3989 459 b)75mm dia. 460 sand cast iron s&s as per is - 3989 461 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 462 a) 100mm 463 b) 75mm 464 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 465 a) 100mm inlet & 75mm outlet. 466 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 467 providing and fixing ptmt urinal cock of approved quality and colour. 468 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 469 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 470 15 mm nominal outer dia pipes 471 20 mm nominal outer dia pipes 472 25 mm nominal outer dia pipes 473 32 mm nominal outer dia pipes 474 providing and fixing brass stop cock of approved quality. 475 15 mm nominal bore 476 providing and fixing gun metal gate valve with wheel of approved quality. 477 a) 25mm dia nominal bore 478 b) 32mm dia nominal bore 479 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 480 a) 25mm. nominal bore 481 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 482 a) 15mm nominal bore 483 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 484 a) 15mm nominal bore 485 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 486 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 487 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 488 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 489 providing & fixing cp brass bib cock of approved quality conforming to is 8931 490 a) 15mm nominal bore 491 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 492 a) 15mm nominal bore 493 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 494 15mm nominal bore 495 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 496 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 497 25mm nominal bore, weighing not less than 62 gms 498 cutting holes up to 30x30 cm in walls including making good the same: 499 with common burnt clay f.p.s. (non modular) bricks 500 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 501 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 502 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 503 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 504 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 505 repair to plaster and plinth protection 506 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 507 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 508 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 509 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 510 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 511 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 512 with cement mortar 1:4 (1cement: 4 coarse sand) 513 12mm cement plaster of mix : 514 1:6 (1 cement : 6 course sand) 515 6mm cement plaster to ceiling of mix : 516 1:3 ( 1 cement : 3 fine sand) 517 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 518 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 519 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 520 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 521 old work (one or more coats) 522 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 523 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 524 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 525 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 526 repairs to door / windows 527 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 528 of area 3 sq. metres and below 529 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 530 of area 3 sq. metres and below 531 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 532 float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 533 renewal of old putty of glass panes (length) 534 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 535 35 mm thick including isi marked stainless steel butt hinges with necessary screws 536 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 537 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 538 300 mm weighing not less than 200gms. 539 250 mm weighing not less than 150gms. 540 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 541 100x58x1.90 mm 542 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 543 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 544 300 x 10mm 545 200 x 10mm 546 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 547 125 mm 548 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 549 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (puf) /polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 550 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 551 with 12 mm mild steel u beading 552 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 553 using flats 30x6mm for diagonal braces and central cross piece 554 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 555 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 556 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size). 557 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 558 4.0 mm thick glass panes 559 applying priming coat : 560 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 561 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 562 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 563 two or more coats on new work 564 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 565 one or more coats on old work 566 miscellaneous 567 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 568 in cement mortar 569 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 570 cement mortar 1:6 (1 cement : 6 coarse sand) 571 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement : 572 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) : 3 graded stone aggregate 20 mm nominal size). 573 centering and shuttering including strutting, propping etc. and removal of form for all heights : 574 edges of slabs and breaks in floors and walls 575 under 20 cm wide 576 centering and shuttering including strutting, propping etc. and removal of form for all heights : 577 suspended floors, roofs, landings, balconies and access platform. 578 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 579 thermo-mechanically treated bars of grade fe-500d or more. 580 electrical work of kitchen & dinning 581 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 582 group c 583 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 584 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 585 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 586 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 587 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 588 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 589 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 590 group c 591 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 592 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 593 2 x 1.5 sq. mm 594 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 595 25 mm 596 32 mm 597 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 598 100 mm x 100 mm x 60 mm deep 599 150 mm x 75 mm x 60 mm deep 600 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 601 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 602 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 603 supplying and fixing brass batten/ angle holder including connection etc. as required. 604 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 605 4 way (4 + 12), double door 606 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 607 single pole 608 single pole and neutral 609 triple pole 610 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 611 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 612 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 613 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/ coke and salt as required. 614 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 615 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 616 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 617 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 618 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 619 supply of 15w surface mounted round led with all accessories as per standard item.. 620 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 621 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 622 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 623 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 624 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 625 450 mm sweep 1400 rpm 626 cost of mp hall 627 structural repair & retrofitting 628 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 629 50 mm average thickness 630 25 mm average thickness 631 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 632 bars upto 12 mm diameter 633 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 634 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 635 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 636 25mm thick in grade m 25 with cement content not less than 330 kg per cum 637 50mm thick in grade m 25 with cement content not less than 330 kg per cum 638 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 639 repairs to roof 640 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 641 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 642 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 643 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 644 asbestos cement sheet 645 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 646 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 647 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 648 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 649 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 650 repair to plaster and plinth protection 651 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 652 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 653 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 654 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 655 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 656 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 657 with cement mortar 1:4 (1cement: 4 coarse sand) 658 12mm cement plaster of mix : 659 1:6 (1 cement : 6 course sand) 660 6mm cement plaster to ceiling of mix : 661 1:3 ( 1 cement : 3 fine sand) 662 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 663 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 664 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 665 old work (one or more coats) 666 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 667 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 668 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 669 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 670 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 671 repairs to door / windows 672 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 673 of area 3 sq. metres and below 674 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 675 of area 3 sq. metres and below 676 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 677 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 678 renewal of old putty of glass panes (length) 679 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 680 35 mm thick including isi marked stainless steel butt hinges with necessary screws 681 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 682 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 683 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 684 300 mm weighing not less than 200gms. 685 250 mm weighing not less than 150gms. 686 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 687 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 688 300 x 10mm 689 150 x 10mm 690 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 691 with 12 mm mild steel u beading 692 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 693 125 mm 694 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 695 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 696 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 697 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 698 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 699 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 700 4.0 mm thick glass panes 701 applying priming coat : 702 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 703 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 704 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 705 two or more coats on new work 706 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 707 one or more coats on old work 708 flooring 709 miscellaneous 710 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 711 in cement mortar 712 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 713 cement mortar 1:6 (1 cement : 6 coarse sand) 714 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 715 cement mortar 1:4 (1 cement :4 coarse sand 716 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 717 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 718 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 719 75 to 80 mm dia pipe 720 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 721 110 mm diameter 722 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 723 a) coupler 724 110 mm 725 b) bend 87.5° 726 110 mm bend 727 electrical work 728 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 729 group c 730 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 731 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 732 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 733 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 734 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 735 2 x 1.5 sq. mm 736 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 737 25 mm 738 32 mm 739 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 740 100 mm x 100 mm x 60 mm deep 741 150 mm x 75 mm x 60 mm deep 742 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 743 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 744 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 745 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 746 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 747 6 way, double door 748 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 749 4 way (4 + 12), double door 750 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 751 single pole 752 single pole and neutral 753 triple pole 754 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 755 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 756 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 757 upto 450 mm sweep 758 supply of 15w surface mounted round led with all accessories as per standard item.. 759 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 760 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 761 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 762 supply of 30w led recess mounted fixturemake-philips cat no.rc380b led30s-6500 l60w60 psd od s1 or equivalent. 763 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 764 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 765 450 mm sweep 1400 rpm 766 boysdormitory (g) for 72 students 767 structural repair & retrofitting 768 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 769 50 mm average thickness 770 25 mm average thickness 771 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 772 bars upto 12 mm diameter 773 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 774 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 775 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 776 25mm thick in grade m 25 with cement content not less than 330 kg per cum 777 50mm thick in grade m 25 with cement content not less than 330 kg per cum 778 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 779 expansion joint treatment 780 providing and fixing of expansion joint system related with floor location as per drawings and direction of engineer-in-charge. the joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per astm b221-02. the system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. system shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. the cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. the self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. provision of moisture barrier membrane in the joint system to have watertight joint is mandatory requirement all as per the manufactures design and as approved by engineer -in- charge. (material shall confirm to astm 6063). 781 floor joint of 100 mm gap 782 providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of engineer-in- charge. the joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per astm b221- 02. the material shall be such that it provides an expansion joints systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office buildings & complexes with no slipping down tendency amongst the components of the joint system. the joint system shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (material shall confirm to astm 6063). 783 wall joint of 100 mm gap 784 providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of engineer-in-charge. the joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per astm b221-02. the system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. system shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. the cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. the self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. the joint system shall resists damage or deterioration from the impact of falling ice, exposure to uv, airborne contaminants and occasional foot traffic from maintenance personnel. provision of moisture barrier membrane in the joint system to have water tight joint is mandatory requirement. (material shall confirm to astm 6063.) 785 roof joint of 100 mm gap 786 repairs to roof 787 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 788 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 789 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 790 repair to toilets 791 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 792 nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 793 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 794 for thickness of tiles 10 mm to 25 mm 795 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 796 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 797 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 798 providing and filling of cinder in sunken portions. 799 repair to plaster and plinth protection 800 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 801 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 802 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 803 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 804 with cement mortar 1:4 (1cement: 4 coarse sand) 805 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 806 15mm cement plaster on rough side of single or half brick wall of mix 807 1:6 (1 cement : 6 course sand) 808 6mm cement plaster to ceiling of mix : 809 1:3 ( 1 cement : 3 fine sand) 810 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 811 two coats 812 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 813 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 814 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 815 washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of engineer-in-charge (payment for providing grooves shall be made separately). 816 forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the engineer-in-charge : 817 15 mm wide and 15 mm deep groove 818 repairs to door / windows 819 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 820 of area 3 sq. metres and below 821 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 822 of area 3 sq. metres and below 823 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 824 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 825 renewal of old putty of glass panes (length) 826 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 827 35 mm thick including isi marked stainless steel butt hinges with necessary screws 828 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 829 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete .fixed to steel windows by welding 830 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 831 300 mm weighing not less than 200gms. 832 250 mm weighing not less than 150gms. 833 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 834 100x58x1.90 mm 835 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 836 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 837 300 x 10mm 838 150 x 10mm 839 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 840 125 mm 841 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 842 twin rubber stopper 843 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 844 providing and fixing to existing door frames. 845 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 846 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4mm in both directions for doors, windows and clerestory windows with necessary screws : 847 35 mm thick shutters.with isi marked stainless steel butt hinges of required size. kiln seasoned and chemically treated hollock wood. 848 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 849 with 12 mm mild steel u beading 850 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 851 using flats 30x6mm for diagonal braces and central cross piece 852 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 853 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 854 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 855 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 856 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 857 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 858 steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 859 in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 860 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 861 4.0 mm thick glass panes 862 applying priming coat : 863 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 864 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 865 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 866 two or more coats on new work 867 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 868 one or more coats on old work 869 repairs to flooring 870 miscellaneous 871 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 872 in cement mortar 873 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 874 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 875 cement mortar 1:6 (1 cement : 6 coarse sand) 876 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 877 cement mortar 1:4 (1 cement :4 coarse sand 878 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 879 plumbing work of boysdormitory (g) for 72 students 880 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 881 75 to 80 mm dia pipe 882 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 883 15 mm to 40 mm nominal bore 884 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 885 up to 150 mm diameter 886 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 887 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 888 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 889 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 890 up to 150 mm diameter 891 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 892 rectangular manhole 90x80 cm and 45 cm deep 893 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 894 110 mm diameter 895 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 896 a) coupler 897 110 mm 898 b) bend 87.5° 899 110 mm bend 900 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 901 75 mm diameter pipes 902 100 mm diameter pipes 903 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 904 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 905 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 906 w.c. pan with isi marked white solid plastic seat and lid 907 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 908 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 909 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 910 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 911 a) 32mm dia (for wash basin) 912 b) 40mm dia (for sink and urinal) 913 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 914 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 915 providing & fixing c.p. brass waste coupling for pvc waste pipe. 916 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 917 110 mm dia (wall thickness - 3.2 to 3.8 mm) 918 75 mm dia (wall thickness - 3.2 to 3.8 mm) 919 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 920 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 921 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 922 p-trap type floor trap 110 x 75 mm 923 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 924 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 925 providing and fixing 100 mm sand cast iron grating for gully trap. 926 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 927 providing and fixing toilet paper holder : 928 vitreous china 929 providing & fixing soil, waste and vent pipes. 930 a) 100mm dia centrifugally cast iron s & s pipe. 931 b)75mm dia centrifugally cast iron s & s pipe. 932 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 933 a) for 100mm dia pipe. 934 b) for 75mm dia pipe. 935 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 936 a) 100mm 937 sand cast iron s&s as per is - 3989 938 b) 75mm 939 sand cast iron s&s as per is- 3989 940 providing and fixing plaincast iron s & s sanitary bend. 941 a) 100mm 942 sand cast iron s&s as per is - 1729 943 b) 75mm 944 sand cast iron s&s as per is - 3989 945 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 946 a) 100x100x100mm 947 b) 75x75x75mm 948 providing and fixingcast iron terminal guard. 949 a) 100mm 950 b) 75mm 951 providing & fixingcast iron coller. 952 a)100 mm 953 sand cast iron s&s as per is - 3989 954 b)75mm dia. 955 sand cast iron s&s as per is - 3989 956 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 957 a) 100mm 958 b) 75mm 959 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 960 a) 100mm inlet & 75mm outlet. 961 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 962 providing and fixing ptmt urinal cock of approved quality and colour. 963 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with bsp female threads weighing not less than 48 gms 964 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 965 15 mm nominal outer dia pipes 966 20 mm nominal outer dia pipes 967 25 mm nominal outer dia pipes 968 32 mm nominal outer dia pipes 969 providing and fixing brass stop cock of approved quality. 970 15 mm nominal bore 971 providing and fixing gun metal gate valve with wheel of approved quality. 972 a) 25mm dia nominal bore 973 b) 32mm dia nominal bore 974 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 975 a) 25mm. nominal bore 976 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 977 a) 15mm nominal bore 978 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 979 a) 15mm nominal bore 980 providing & fixing cp brass bib cock of approved quality conforming to is 8931 981 a) 15mm nominal bore 982 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 983 a) 15mm nominal bore 984 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 985 15mm nominal bore 986 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 987 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 988 25mm nominal bore, weighing not less than 62 gms 989 cutting holes up to 30x30 cm in walls including making good the same: 990 with common burnt clay f.p.s. (non modular) bricks 991 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 992 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 993 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 994 electrical work of boysdormitory (g) for 72 students 995 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 996 group b 997 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 998 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 999 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1000 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1001 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1002 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1003 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1004 group b 1005 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1006 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1007 2 x 1.5 sq. mm 1008 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1009 25 mm 1010 32 mm 1011 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1012 100 mm x 100 mm x 60 mm deep 1013 150 mm x 75 mm x 60 mm deep 1014 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1015 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1016 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1017 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1018 supplying and fixing brass batten/ angle holder including connection etc. as required. 1019 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1020 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1021 6 way, double door 1022 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1023 4 way (4 + 12), double door 1024 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1025 single pole 1026 single pole and neutral 1027 triple pole 1028 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1029 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1030 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1031 supply of 15w surface mounted round led with all accessories as per standard item.. 1032 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1033 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1034 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1035 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 1036 girls dormitories(cpwd type) 1 block 1037 structural repair & retrofitting 1038 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1039 50mm average thickness 1040 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1041 bars upto 12 mm diameter 1042 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1043 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1044 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1045 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1046 repairs to roof 1047 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1048 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1049 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1050 repair to toilets 1051 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1052 for thickness of tiles 10 mm to 25 mm 1053 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1054 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1055 repair to plaster and plinth protection 1056 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. 1057 two or more coats on new work 1058 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1059 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1060 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1061 15mm cement plaster on rough side of single or half brick wall of mix 1062 1:6 (1 cement : 6 course sand) 1063 6mm cement plaster to ceiling of mix : 1064 1:3 ( 1 cement : 3 fine sand) 1065 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1066 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1067 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1068 old work (one or more coats) 1069 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1070 washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of engineer-in-charge (payment for providing grooves shall be made separately). 1071 forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the engineer-in-charge : 1072 15 mm wide and 15 mm deep groove 1073 repairs to door / windows 1074 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1075 of area 3 sq. metres and below 1076 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1077 of area 3 sq. metres and below 1078 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 1079 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1080 renewal of old putty of glass panes (length) 1081 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete .fixed to steel windows by welding 1082 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1083 250 mm weighing not less than 150gms. 1084 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1085 100x58x1.90 mm 1086 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1087 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1088 300 x 10mm 1089 150 x 10mm 1090 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1091 125 mm 1092 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1093 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1094 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1095 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including isi marked stainless steel butt hinges with necessary screws 1096 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1.5 mm thick. 1097 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 1098 with 12 mm mild steel u beading 1099 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1100 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1101 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 1102 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1103 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1104 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1105 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1106 4.0 mm thick glass panes 1107 applying priming coat : 1108 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1109 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1110 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1111 two or more coats on new work 1112 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1113 one or more coats on old work 1114 miscellaneous 1115 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 1116 in cement mortar 1117 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1118 cement mortar 1:6 (1 cement : 6 coarse sand) 1119 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1120 cement mortar 1:4 (1 cement :4 coarse sand 1121 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1122 plumbing work of girlsdormitory (g) for 48 students 1123 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1124 75 to 80 mm dia pipe 1125 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1126 15 mm to 40 mm nominal bore 1127 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1128 up to 150 mm diameter 1129 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1130 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1131 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1132 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1133 up to 150 mm diameter 1134 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1135 rectangular manhole 90x80 cm and 45 cm deep 1136 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1137 110 mm diameter 1138 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1139 a) coupler 1140 110 mm 1141 b) bend 87.5° 1142 110 mm bend 1143 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1144 75 mm diameter pipes 1145 100 mm diameter pipes 1146 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1147 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1148 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1149 w.c. pan with isi marked white solid plastic seat and lid 1150 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1151 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1152 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1153 a) 32mm dia (for wash basin) 1154 b) 40mm dia (for sink and urinal) 1155 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 1156 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1157 providing & fixing c.p. brass waste coupling for pvc waste pipe. 1158 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382.the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1159 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1160 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1161 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1162 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1163 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1164 p-trap type floor trap 110 x 75 mm 1165 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1166 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1167 providing and fixing 100 mm sand cast iron grating for gully trap. 1168 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1169 providing and fixing toilet paper holder : 1170 vitreous china 1171 providing & fixing soil, waste and vent pipes. 1172 a) 100mm dia centrifugally cast iron s & s pipe. 1173 b)75mm dia centrifugally cast iron s & s pipe. 1174 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1175 a) for 100mm dia pipe. 1176 b) for 75mm dia pipe. 1177 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1178 a) 100mm 1179 sand cast iron s&s as per is - 3989 1180 b) 75mm 1181 sand cast iron s&s as per is- 3989 1182 providing and fixing plaincast iron s & s sanitary bend. 1183 a) 100mm 1184 sand cast iron s&s as per is - 1729 1185 b) 75mm 1186 sand cast iron s&s as per is - 3989 1187 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1188 a) 100x100x100mm 1189 b) 75x75x75mm 1190 providing and fixingcast iron terminal guard. 1191 a) 100mm 1192 b) 75mm 1193 providing & fixingcast iron coller. 1194 a)100 mm 1195 sand cast iron s&s as per is - 3989 1196 b)75mm dia. 1197 sand cast iron s&s as per is - 3989 1198 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1199 a) 100mm 1200 b) 75mm 1201 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1202 a) 100mm inlet & 75mm outlet. 1203 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1204 15 mm nominal outer dia pipes 1205 20 mm nominal outer dia pipes 1206 25 mm nominal outer dia pipes 1207 32 mm nominal outer dia pipes 1208 providing and fixing brass stop cock of approved quality. 1209 15 mm nominal bore 1210 providing and fixing gun metal gate valve with wheel of approved quality. 1211 a) 25mm dia nominal bore 1212 b) 32mm dia nominal bore 1213 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1214 a) 25mm. nominal bore 1215 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1216 a) 15mm nominal bore 1217 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1218 a) 15mm nominal bore 1219 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1220 a) 15mm nominal bore 1221 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1222 a) 15mm nominal bore 1223 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1224 15mm nominal bore 1225 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1226 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1227 25mm nominal bore, weighing not less than 62 gms 1228 cutting holes up to 30x30 cm in walls including making good the same: 1229 with common burnt clay f.p.s. (non modular) bricks 1230 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1231 electrical work of girlsdormitory (g) for 48 students 1232 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1233 group b 1234 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1235 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1236 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1237 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1238 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1239 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1240 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1241 group b 1242 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1243 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1244 2 x 1.5 sq. mm 1245 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1246 25 mm 1247 32 mm 1248 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1249 100 mm x 100 mm x 60 mm deep 1250 150 mm x 75 mm x 60 mm deep 1251 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1252 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1253 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1254 supplying and fixing brass batten/ angle holder including connection etc. as required. 1255 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1256 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1257 4 way (4 + 12), double door 1258 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1259 single pole 1260 single pole and neutral 1261 triple pole 1262 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1263 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1264 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1265 supply of 15w surface mounted round led with all accessories as per standard item.. 1266 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1267 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1268 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1269 staff qtrs type-iii . 1270 structural repair & retrofitting 1271 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1272 50 mm average thickness 1273 25 mm average thickness 1274 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1275 bars upto 12 mm diameter 1276 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1277 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1278 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1279 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1280 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1281 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 1282 repairs to roof 1283 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1284 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1285 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1286 repair to toilets 1287 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1288 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1289 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1290 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1291 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1292 providing and filling of cinder in sunken portions. 1293 repair to plaster and plinth protection 1294 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1295 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1296 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1297 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1298 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1299 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1300 with cement mortar 1:4 (1cement: 4 coarse sand) 1301 12mm cement plaster of mix : 1302 1:6 (1 cement : 6 course sand) 1303 6mm cement plaster to ceiling of mix : 1304 1:3 ( 1 cement : 3 fine sand) 1305 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1306 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1307 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1308 old work (one or more coats) 1309 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1310 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1311 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1312 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1313 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1314 repairs to door / windows 1315 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1316 of area 3 sq. metres and below 1317 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1318 of area 3 sq. metres and below 1319 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1320 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1321 renewal of old putty of glass panes (length) 1322 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1323 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1324 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1325 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1326 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1327 300 mm weighing not less than 200gms. 1328 250 mm weighing not less than 150gms. 1329 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1330 100x58x1.90 mm 1331 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1332 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1333 300 x 10mm 1334 150 x 10mm 1335 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 1336 providing and fixing to existing door frames. 1337 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1338 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1339 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1340 with isi marked stainless steel butt hinges of required size 1341 kiln seasoned and chemically treated hollock wood 1342 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1343 with 12 mm mild steel u beading 1344 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1345 125 mm 1346 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1347 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1348 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1349 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1350 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1351 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1352 4.0 mm thick glass panes 1353 applying priming coat : 1354 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1355 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1356 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1357 two or more coats on new work 1358 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1359 one or more coats on old work 1360 miscellaneous 1361 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1362 cement mortar 1:6 (1 cement : 6 coarse sand) 1363 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1364 cement mortar 1:4 (1 cement :4 coarse sand 1365 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1366 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1367 plumbing work of type-iii (g+1) 1368 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1369 75 to 80 mm dia pipe 1370 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1371 15 mm to 40 mm nominal bore 1372 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1373 up to 150 mm diameter 1374 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1375 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1376 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1377 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1378 up to 150 mm diameter 1379 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1380 rectangular manhole 90x80 cm and 45 cm deep 1381 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1382 110 mm diameter 1383 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1384 a) coupler 1385 110 mm 1386 b) bend 87.5° 1387 110 mm bend 1388 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1389 75 mm diameter pipes 1390 100 mm diameter pipes 1391 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1392 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1393 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1394 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1395 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1396 kitchen sink without drain board 1397 610x510 mm bowl depth 200 mm 1398 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1399 a) 32mm dia (for wash basin) 1400 b) 40mm dia (for sink and urinal) 1401 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1402 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1403 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1404 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1405 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1406 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1407 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1408 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1409 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1410 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1411 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1412 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1413 p-trap type floor trap 110 x 75 mm 1414 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1415 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1416 providing and fixing 100 mm sand cast iron grating for gully trap. 1417 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1418 providing & fixing soil, waste and vent pipes. 1419 a) 100mm dia centrifugally cast iron s & s pipe. 1420 b)75mm dia centrifugally cast iron s & s pipe. 1421 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1422 a) for 100mm dia pipe. 1423 b) for 75mm dia pipe. 1424 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1425 a) 100mm 1426 sand cast iron s&s as per is - 3989 1427 b) 75mm 1428 sand cast iron s&s as per is- 3989 1429 providing and fixing plaincast iron s & s sanitary bend. 1430 a) 100mm 1431 sand cast iron s&s as per is - 1729 1432 b) 75mm 1433 sand cast iron s&s as per is - 3989 1434 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1435 a) 100x100x100mm 1436 b) 75x75x75mm 1437 providing and fixingcast iron terminal guard. 1438 a) 100mm 1439 b) 75mm 1440 providing & fixingcast iron coller. 1441 a)100 mm 1442 sand cast iron s&s as per is - 3989 1443 b)75mm dia. 1444 sand cast iron s&s as per is - 3989 1445 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1446 a) 100mm 1447 b) 75mm 1448 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1449 a) 100mm inlet & 75mm outlet. 1450 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1451 15 mm nominal outer dia pipes 1452 20 mm nominal outer dia pipes 1453 25 mm nominal outer dia pipes 1454 32 mm nominal outer dia pipes 1455 providing and fixing brass stop cock of approved quality. 1456 15 mm nominal bore 1457 providing and fixing gun metal gate valve with wheel of approved quality. 1458 a) 25mm dia nominal bore 1459 b) 32mm dia nominal bore 1460 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1461 a) 25mm. nominal bore 1462 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1463 a) 15mm nominal bore 1464 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1465 a) 15mm nominal bore 1466 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1467 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1468 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1469 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1470 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1471 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1472 a) 15mm nominal bore 1473 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1474 a) 15mm nominal bore 1475 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1476 a) 15mm nominal bore 1477 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1478 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1479 25mm nominal bore, weighing not less than 62 gms 1480 cutting holes up to 30x30 cm in walls including making good the same: 1481 with common burnt clay f.p.s. (non modular) bricks 1482 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1483 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1484 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1485 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1486 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1487 electrical work of type-iii (g+1) 1488 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1489 group b 1490 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1491 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1492 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1493 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1494 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1495 xxxx 1496 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1497 group b 1498 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1499 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1500 2 x 1.5 sq. mm 1501 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1502 25 mm 1503 32 mm 1504 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1505 100 mm x 100 mm x 60 mm deep 1506 150 mm x 75 mm x 60 mm deep 1507 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1508 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1509 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1510 s/f light plug point modular type accessories :- 1511 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1512 s/f power plug point modular type accessories :- 1513 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1514 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1515 supplying and fixing brass batten/ angle holder including connection etc. as required. 1516 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1517 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1518 6 way, double door 1519 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1520 4 way (4 + 12), double door 1521 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1522 single pole 1523 single pole and neutral 1524 triple pole 1525 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1526 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1527 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1528 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1529 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1530 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1531 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1532 supply of 15w surface mounted round led with all accessories as per standard item.. 1533 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1534 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1535 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1536 staff qtrs type-iii . 1537 structural repair & retrofitting 1538 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1539 50 mm average thickness 1540 25 mm average thickness 1541 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1542 bars upto 12 mm diameter 1543 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1544 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1545 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1546 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1547 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1548 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 1549 repairs to roof 1550 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1551 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1552 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1553 repair to toilets 1554 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1555 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1556 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1557 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1558 repair to plaster and plinth protection 1559 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1560 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1561 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1562 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1563 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1564 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1565 with cement mortar 1:4 (1cement: 4 coarse sand) 1566 12mm cement plaster of mix : 1567 1:6 (1 cement : 6 course sand) 1568 6mm cement plaster to ceiling of mix : 1569 1:3 ( 1 cement : 3 fine sand) 1570 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1571 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1572 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1573 old work (one or more coats) 1574 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1575 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1576 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1577 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1578 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1579 repairs to door / windows 1580 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1581 of area 3 sq. metres and below 1582 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1583 of area 3 sq. metres and below 1584 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1585 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1586 renewal of old putty of glass panes (length) 1587 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1588 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1589 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1590 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1591 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1592 300 mm weighing not less than 200gms. 1593 250 mm weighing not less than 150gms. 1594 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1595 100x58x1.90 mm 1596 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1597 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1598 300 x 10mm 1599 150 x 10mm 1600 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 1601 providing and fixing to existing door frames. 1602 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1603 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1604 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1605 with isi marked stainless steel butt hinges of required size 1606 kiln seasoned and chemically treated hollock wood 1607 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1608 with 12 mm mild steel u beading 1609 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1610 125 mm 1611 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1612 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1613 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1614 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1615 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1616 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1617 4.0 mm thick glass panes 1618 applying priming coat : 1619 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1620 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1621 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1622 two or more coats on new work 1623 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1624 one or more coats on old work 1625 flooring 1626 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1627 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1628 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1629 25 mm thick 1630 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1631 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 1632 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 1633 miscellaneous 1634 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1635 cement mortar 1:6 (1 cement : 6 coarse sand) 1636 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1637 cement mortar 1:4 (1 cement :4 coarse sand 1638 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1639 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1640 plumbing work of type-iii (g) 1641 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1642 75 to 80 mm dia pipe 1643 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1644 15 mm to 40 mm nominal bore 1645 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1646 up to 150 mm diameter 1647 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1648 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1649 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1650 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1651 up to 150 mm diameter 1652 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1653 rectangular manhole 90x80 cm and 45 cm deep 1654 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1655 110 mm diameter 1656 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1657 a) coupler 1658 110 mm 1659 b) bend 87.5° 1660 110 mm bend 1661 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1662 75 mm diameter pipes 1663 100 mm diameter pipes 1664 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1665 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1666 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1667 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1668 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1669 kitchen sink without drain board 1670 610x510 mm bowl depth 200 mm 1671 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1672 a) 32mm dia (for wash basin) 1673 b) 40mm dia (for sink and urinal) 1674 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1675 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1676 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1677 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1678 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1679 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1680 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1681 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1682 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1683 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1684 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1685 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1686 p-trap type floor trap 110 x 75 mm 1687 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1688 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1689 providing and fixing 100 mm sand cast iron grating for gully trap. 1690 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1691 providing & fixing soil, waste and vent pipes. 1692 a) 100mm dia centrifugally cast iron s & s pipe. 1693 b)75mm dia centrifugally cast iron s & s pipe. 1694 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1695 a) for 100mm dia pipe. 1696 b) for 75mm dia pipe. 1697 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1698 a) 100mm 1699 sand cast iron s&s as per is - 3989 1700 b) 75mm 1701 sand cast iron s&s as per is- 3989 1702 providing and fixing plaincast iron s & s sanitary bend. 1703 a) 100mm 1704 sand cast iron s&s as per is - 1729 1705 b) 75mm 1706 sand cast iron s&s as per is - 3989 1707 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1708 a) 100x100x100mm 1709 b) 75x75x75mm 1710 providing and fixingcast iron terminal guard. 1711 a) 100mm 1712 b) 75mm 1713 providing & fixingcast iron coller. 1714 a)100 mm 1715 sand cast iron s&s as per is - 3989 1716 b)75mm dia. 1717 sand cast iron s&s as per is - 3989 1718 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1719 a) 100mm 1720 b) 75mm 1721 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1722 a) 100mm inlet & 75mm outlet. 1723 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1724 15 mm nominal outer dia pipes 1725 20 mm nominal outer dia pipes 1726 25 mm nominal outer dia pipes 1727 32 mm nominal outer dia pipes 1728 providing and fixing brass stop cock of approved quality. 1729 15 mm nominal bore 1730 providing and fixing gun metal gate valve with wheel of approved quality. 1731 a) 25mm dia nominal bore 1732 b) 32mm dia nominal bore 1733 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1734 a) 25mm. nominal bore 1735 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1736 a) 15mm nominal bore 1737 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1738 a) 15mm nominal bore 1739 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1740 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1741 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1742 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1743 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1744 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1745 a) 15mm nominal bore 1746 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1747 a) 15mm nominal bore 1748 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1749 a) 15mm nominal bore 1750 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1751 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1752 25mm nominal bore, weighing not less than 62 gms 1753 cutting holes up to 30x30 cm in walls including making good the same: 1754 with common burnt clay f.p.s. (non modular) bricks 1755 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1756 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1757 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1758 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1759 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1760 electrical work of type-iii (g) 1761 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1762 group b 1763 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1764 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1765 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1766 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1767 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1768 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1769 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1770 group b 1771 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1772 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1773 2 x 1.5 sq. mm 1774 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1775 25 mm 1776 32 mm 1777 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1778 100 mm x 100 mm x 60 mm deep 1779 150 mm x 75 mm x 60 mm deep 1780 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1781 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1782 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1783 s/f light plug point modular type accessories :- 1784 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1785 s/f power plug point modular type accessories :- 1786 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1787 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1788 supplying and fixing brass batten/ angle holder including connection etc. as required. 1789 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1790 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1791 6 way, double door 1792 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1793 4 way (4 + 12), double door 1794 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1795 single pole 1796 single pole and neutral 1797 triple pole 1798 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1799 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1800 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1801 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1802 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1803 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1804 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1805 supply of 15w surface mounted round led with all accessories as per standard item.. 1806 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1807 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1808 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1809 type-ii staff qtrs. 1810 structural repair & retrofitting 1811 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1812 25 mm average thickness 1813 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1814 bars upto 12 mm diameter 1815 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1816 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1817 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1818 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1819 repairs to roof 1820 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1821 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1822 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1823 repair to toilets 1824 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1825 for thickness of tiles 10 mm to 25 mm 1826 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1827 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1828 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1829 providing and filling of cinder in sunken portions. 1830 repair to plaster and plinth protection 1831 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1832 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1833 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1834 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1835 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1836 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1837 with cement mortar 1:4 (1cement: 4 coarse sand) 1838 15mm cement plaster of mix : 1839 1:6 (1 cement : 6 course sand) 1840 pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1841 raised and cut pointing 1842 6mm cement plaster to ceiling of mix : 1843 1:3 ( 1 cement : 3 fine sand) 1844 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1845 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1846 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1847 old work (one or more coats) 1848 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1849 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1850 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1851 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1852 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1853 repairs to door / windows 1854 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1855 of area 3 sq. metres and below 1856 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1857 of area 3 sq. metres and below 1858 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1859 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1860 renewal of old putty of glass panes (length) 1861 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1862 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1863 250 mm weighing not less than 150gms. 1864 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1865 100x58x1.90 mm 1866 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1867 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1868 300 x 10mm 1869 150 x 10mm 1870 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1871 125 mm 1872 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1873 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including isi marked stainless steel butt hinges with necessary screws 1874 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1.5 mm thick. 1875 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1876 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1877 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1878 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1879 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1880 4.0 mm thick glass panes 1881 applying priming coat : 1882 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1883 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1884 two or more coats on new work 1885 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1886 one or more coats on old work 1887 miscellaneous 1888 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1889 cement mortar 1:6 (1 cement : 6 coarse sand) 1890 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1891 cement mortar 1:4 (1 cement :4 coarse sand 1892 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1893 plumbing work 1894 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1895 75 to 80 mm dia pipe 1896 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1897 15 mm to 40 mm nominal bore 1898 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1899 up to 150 mm diameter 1900 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1901 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1902 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1903 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1904 up to 150 mm diameter 1905 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1906 rectangular manhole 90x80 cm and 45 cm deep 1907 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1908 110 mm diameter 1909 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1910 a) coupler 1911 110 mm 1912 b) bend 87.5° 1913 110 mm bend 1914 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1915 75 mm diameter pipes 1916 100 mm diameter pipes 1917 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1918 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1919 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1920 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1921 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1922 kitchen sink without drain board 1923 610x510 mm bowl depth 200 mm 1924 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1925 a) 32mm dia (for wash basin) 1926 b) 40mm dia (for sink and urinal) 1927 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1928 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1929 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1930 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1931 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1932 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1933 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1934 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1935 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1936 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1937 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1938 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1939 p-trap type floor trap 110 x 75 mm 1940 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1941 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1942 providing and fixing 100 mm sand cast iron grating for gully trap. 1943 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1944 providing & fixing soil, waste and vent pipes. 1945 a) 100mm dia centrifugally cast iron s & s pipe. 1946 b)75mm dia centrifugally cast iron s & s pipe. 1947 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1948 a) for 100mm dia pipe. 1949 b) for 75mm dia pipe. 1950 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1951 a) 100mm 1952 sand cast iron s&s as per is - 3989 1953 b) 75mm 1954 sand cast iron s&s as per is- 3989 1955 providing and fixing plaincast iron s & s sanitary bend. 1956 a) 100mm 1957 sand cast iron s&s as per is - 1729 1958 b) 75mm 1959 sand cast iron s&s as per is - 3989 1960 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1961 a) 100x100x100mm 1962 b) 75x75x75mm 1963 providing and fixingcast iron terminal guard. 1964 a) 100mm 1965 b) 75mm 1966 providing & fixingcast iron coller. 1967 a)100 mm 1968 sand cast iron s&s as per is - 3989 1969 b)75mm dia. 1970 sand cast iron s&s as per is - 3989 1971 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1972 a) 100mm 1973 b) 75mm 1974 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1975 a) 100mm inlet & 75mm outlet. 1976 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1977 15 mm nominal outer dia pipes 1978 20 mm nominal outer dia pipes 1979 25 mm nominal outer dia pipes 1980 32 mm nominal outer dia pipes 1981 providing and fixing brass stop cock of approved quality. 1982 15 mm nominal bore 1983 providing and fixing gun metal gate valve with wheel of approved quality. 1984 a) 25mm dia nominal bore 1985 b) 32mm dia nominal bore 1986 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1987 a) 25mm. nominal bore 1988 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1989 a) 15mm nominal bore 1990 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1991 a) 15mm nominal bore 1992 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1993 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1994 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1995 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1996 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1997 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1998 a) 15mm nominal bore 1999 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2000 a) 15mm nominal bore 2001 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2002 a) 15mm nominal bore 2003 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2004 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2005 25mm nominal bore, weighing not less than 62 gms 2006 cutting holes up to 30x30 cm in walls including making good the same: 2007 with common burnt clay f.p.s. (non modular) bricks 2008 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2009 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2010 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2011 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2012 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2013 electrical work 2014 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2015 group b 2016 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2017 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2018 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2019 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2020 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2021 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2022 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2023 group b 2024 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2025 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2026 2 x 1.5 sq. mm 2027 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2028 25 mm 2029 32 mm 2030 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2031 100 mm x 100 mm x 60 mm deep 2032 150 mm x 75 mm x 60 mm deep 2033 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2034 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2035 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2036 s/f light plug point modular type accessories :- 2037 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 2038 s/f power plug point modular type accessories :- 2039 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 2040 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2041 supplying and fixing brass batten/ angle holder including connection etc. as required. 2042 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2043 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2044 6 way, double door 2045 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2046 4 way (4 + 12), double door 2047 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2048 single pole 2049 single pole and neutral 2050 triple pole 2051 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2052 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2053 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2054 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2055 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2056 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2057 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2058 supply of 15w surface mounted round led with all accessories as per standard item.. 2059 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2060 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2061 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2062 staff qtrs type-i . 2063 structural repair & retrofitting 2064 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 2065 50 mm average thickness 2066 25 mm average thickness 2067 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 2068 bars upto 12 mm diameter 2069 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 2070 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 2071 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 2072 25mm thick in grade m 25 with cement content not less than 330 kg per cum 2073 50mm thick in grade m 25 with cement content not less than 330 kg per cum 2074 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 2075 repairs to roof 2076 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2077 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2078 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2079 repair to toilets 2080 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2081 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2082 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 2083 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2084 repair to plaster and plinth protection 2085 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2086 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2087 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2088 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2089 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2090 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2091 with cement mortar 1:4 (1cement: 4 coarse sand) 2092 12mm cement plaster of mix : 2093 1:6 (1 cement : 6 course sand) 2094 6mm cement plaster to ceiling of mix : 2095 1:3 ( 1 cement : 3 fine sand) 2096 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2097 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2098 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2099 old work (one or more coats) 2100 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2101 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2102 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2103 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2104 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2105 repairs to door / windows 2106 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2107 of area 3 sq. metres and below 2108 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2109 of area 3 sq. metres and below 2110 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2111 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2112 renewal of old putty of glass panes (length) 2113 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2114 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2115 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2116 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 2117 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2118 300 mm weighing not less than 200gms. 2119 250 mm weighing not less than 150gms. 2120 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 2121 100x58x1.90 mm 2122 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2123 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2124 300 x 10mm 2125 150 x 10mm 2126 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 2127 providing and fixing to existing door frames. 2128 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 2129 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2130 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2131 with isi marked stainless steel butt hinges of required size 2132 kiln seasoned and chemically treated hollock wood 2133 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2134 with 12 mm mild steel u beading 2135 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2136 125 mm 2137 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2138 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2139 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2140 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2141 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2142 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2143 4.0 mm thick glass panes 2144 applying priming coat : 2145 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 2146 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2147 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2148 two or more coats on new work 2149 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2150 one or more coats on old work 2151 flooring 2152 miscellaneous 2153 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2154 cement mortar 1:6 (1 cement : 6 coarse sand) 2155 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2156 cement mortar 1:4 (1 cement :4 coarse sand 2157 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2158 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2159 plumbing work of type-i (g) 2160 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2161 75 to 80 mm dia pipe 2162 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2163 15 mm to 40 mm nominal bore 2164 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2165 up to 150 mm diameter 2166 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2167 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2168 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2169 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2170 up to 150 mm diameter 2171 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2172 rectangular manhole 90x80 cm and 45 cm deep 2173 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2174 110 mm diameter 2175 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2176 a) coupler 2177 110 mm 2178 b) bend 87.5° 2179 110 mm bend 2180 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 2181 75 mm diameter pipes 2182 100 mm diameter pipes 2183 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2184 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2185 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2186 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2187 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2188 kitchen sink without drain board 2189 610x510 mm bowl depth 200 mm 2190 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2191 a) 32mm dia (for wash basin) 2192 b) 40mm dia (for sink and urinal) 2193 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2194 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2195 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2196 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2197 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 2198 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2199 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2200 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2201 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2202 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2203 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2204 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2205 p-trap type floor trap 110 x 75 mm 2206 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2207 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2208 providing and fixing 100 mm sand cast iron grating for gully trap. 2209 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2210 providing & fixing soil, waste and vent pipes. 2211 a) 100mm dia centrifugally cast iron s & s pipe. 2212 b)75mm dia centrifugally cast iron s & s pipe. 2213 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 2214 a) for 100mm dia pipe. 2215 b) for 75mm dia pipe. 2216 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 2217 a) 100mm 2218 sand cast iron s&s as per is - 3989 2219 b) 75mm 2220 sand cast iron s&s as per is- 3989 2221 providing and fixing plaincast iron s & s sanitary bend. 2222 a) 100mm 2223 sand cast iron s&s as per is - 1729 2224 b) 75mm 2225 sand cast iron s&s as per is - 3989 2226 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 2227 a) 100x100x100mm 2228 b) 75x75x75mm 2229 providing and fixingcast iron terminal guard. 2230 a) 100mm 2231 b) 75mm 2232 providing & fixingcast iron coller. 2233 a)100 mm 2234 sand cast iron s&s as per is - 3989 2235 b)75mm dia. 2236 sand cast iron s&s as per is - 3989 2237 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 2238 a) 100mm 2239 b) 75mm 2240 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 2241 a) 100mm inlet & 75mm outlet. 2242 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2243 15 mm nominal outer dia pipes 2244 20 mm nominal outer dia pipes 2245 25 mm nominal outer dia pipes 2246 32 mm nominal outer dia pipes 2247 providing and fixing brass stop cock of approved quality. 2248 15 mm nominal bore 2249 providing and fixing gun metal gate valve with wheel of approved quality. 2250 a) 25mm dia nominal bore 2251 b) 32mm dia nominal bore 2252 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2253 a) 25mm. nominal bore 2254 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2255 a) 15mm nominal bore 2256 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2257 a) 15mm nominal bore 2258 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2259 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2260 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2261 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2262 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2263 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2264 a) 15mm nominal bore 2265 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2266 a) 15mm nominal bore 2267 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2268 a) 15mm nominal bore 2269 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2270 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2271 25mm nominal bore, weighing not less than 62 gms 2272 cutting holes up to 30x30 cm in walls including making good the same: 2273 with common burnt clay f.p.s. (non modular) bricks 2274 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2275 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2276 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2277 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2278 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2279 electrical work of type-i (g) 2280 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2281 group b 2282 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2283 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2284 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2285 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2286 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2287 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2288 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2289 group b 2290 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2291 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2292 2 x 1.5 sq. mm 2293 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2294 25 mm 2295 32 mm 2296 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2297 100 mm x 100 mm x 60 mm deep 2298 150 mm x 75 mm x 60 mm deep 2299 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2300 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2301 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2302 s/f light plug point modular type accessories :- 2303 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 2304 s/f power plug point modular type accessories :- 2305 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 2306 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2307 supplying and fixing brass batten/ angle holder including connection etc. as required. 2308 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2309 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2310 6 way, double door 2311 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2312 4 way (4 + 12), double door 2313 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2314 single pole 2315 single pole and neutral 2316 triple pole 2317 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2318 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2319 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2320 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2321 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2322 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2323 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2324 supply of 15w surface mounted round led with all accessories as per standard item.. 2325 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2326 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2327 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2328 type-i (g) 5 units 2329 repairs to roof 2330 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 2331 asbestos cement sheet 2332 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 2333 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 2334 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, 2335 shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 2336 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 2337 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m* 2338 repairs to toilets 2339 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2340 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2341 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 2342 for thickness of tiles 10 mm to 25 mm 2343 providing and fixing ist quality glazed vitrified tiles polished finish of size 450 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2344 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 2345 repair to plaster & plinth protection 2346 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2347 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2348 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2349 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2350 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2351 with cement mortar 1:4 (1cement: 4 coarse sand) 2352 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2353 12mm cement plaster of mix : 2354 1:6 (1 cement : 6 course sand) 2355 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2356 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2357 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2358 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2359 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2360 old work (one or more coats) 2361 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2362 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2363 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2364 repairs to door/windows 2365 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2366 of area 3 sq. metres and below 2367 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2368 of area 3 sq. metres and below 2369 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 2370 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2371 renewal of old putty of glass panes (length) 2372 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2373 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2374 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2375 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 2376 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2377 300 mm weighing not less than 200gms. 2378 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2379 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2380 300 x 10mm 2381 150 x 10mm 2382 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2383 125 mm 2384 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 2385 twin rubber stopper 2386 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2387 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2388 with isi marked stainless steel butt hinges of required size 2389 kiln seasoned and chemically treated hollock wood 2390 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2391 with 12 mm mild steel u beading 2392 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2393 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2394 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2395 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2396 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2397 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2398 4.0 mm thick glass panes 2399 applying priming coat : 2400 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 2401 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2402 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2403 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2404 one or more coats on old work 2405 miscellaneous 2406 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2407 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 2408 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 2409 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2410 cement mortar 1:6 (1 cement : 6 coarse sand) 2411 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2412 cement mortar 1:4 (1 cement :4 coarse sand 2413 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2414 plumbing work of type-i (g) 5 units 2415 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2416 15 mm to 40 mm nominal bore 2417 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2418 up to 150 mm diameter 2419 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2420 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2421 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2422 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 2423 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2424 up to 150 mm diameter 2425 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2426 rectangular manhole 90x80 cm and 45 cm deep 2427 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2428 110 mm diameter 2429 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2430 a) coupler 2431 110 mm 2432 b) bend 87.5° 2433 110 mm bend 2434 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2435 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2436 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2437 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2438 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2439 kitchen sink without drain board 2440 610x510 mm bowl depth 200 mm 2441 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2442 a) 32mm dia (for wash basin) 2443 b) 40mm dia (for sink and urinal) 2444 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2445 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2446 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2447 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2448 providing & fixing c.p. brass waste coupling for pvc waste pipe. 2449 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2450 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2451 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2452 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2453 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2454 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2455 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2456 p-trap type floor trap 110 x 75 mm 2457 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2458 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2459 providing and fixing 100 mm sand cast iron grating for gully trap. 2460 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2461 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2462 15 mm nominal outer dia pipes 2463 20 mm nominal outer dia pipes 2464 25 mm nominal outer dia pipes 2465 32 mm nominal outer dia pipes 2466 providing and fixing brass stop cock of approved quality. 2467 15 mm nominal bore 2468 providing and fixing gun metal gate valve with wheel of approved quality. 2469 a) 25mm dia nominal bore 2470 b) 32mm dia nominal bore 2471 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2472 a) 25mm. nominal bore 2473 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2474 a) 15mm nominal bore 2475 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2476 a) 15mm nominal bore 2477 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2478 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2479 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2480 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2481 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2482 a) 15mm nominal bore 2483 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2484 a) 15mm nominal bore 2485 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2486 a) 15mm nominal bore 2487 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2488 cutting holes up to 30x30 cm in walls including making good the same: 2489 with common burnt clay f.p.s. (non modular) bricks 2490 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2491 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2492 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2493 electrical work of type-i (g) 5 units 2494 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2495 group b 2496 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2497 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2498 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2499 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2500 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2501 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2502 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2503 group b 2504 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2505 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2506 2 x 1.5 sq. mm 2507 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2508 25 mm 2509 32 mm 2510 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2511 100 mm x 100 mm x 60 mm deep 2512 150 mm x 75 mm x 60 mm deep 2513 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2514 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2515 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2516 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2517 supplying and fixing brass batten/ angle holder including connection etc. as required. 2518 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2519 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2520 6 way, double door 2521 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2522 4 way (4 + 12), double door 2523 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2524 single pole 2525 single pole and neutral 2526 triple pole 2527 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2528 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2529 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2530 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2531 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2532 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2533 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2534 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover 3on the fan box etc. as required. 2535 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2536 upto 450 mm sweep 2537 supply of 15w surface mounted round led with all accessories as per standard item.. 2538 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2539 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2540 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2541 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2542 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2543 300 mm sweep 1300 rpm 2544 cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia pvc pipe conforming bis-12818 and making good the same etc. complete as per direction of engineer-in-charge. 2545 lightning conductor 2546 providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, g.i. tube, having single prong at top, with 85 mm dia 6 mm thick g.i. base plate including holes etc. complete as required. 2547 fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 2548 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 2549 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 2550 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2551 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2552 providing and fixing testing joint, made of 20 mm x 3 mm thick g.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chuck nuts and spring washers etc. complete as required. 2553 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. details of cost for one set 2554 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re-filling etc. as required. 2555 cost of type- 4 2556 structural repair & retrofitting 2557 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 2558 50 mm average thickness 2559 25 mm average thickness 2560 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 2561 bars upto 12 mm diameter 2562 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 2563 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 2564 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 2565 25mm thick in grade m 25 with cement content not less than 330 kg per cum 2566 50mm thick in grade m 25 with cement content not less than 330 kg per cum 2567 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 2568 repairs to roof 2569 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2570 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2571 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2572 repair to toilets 2573 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 2574 for thickness of tiles 10 mm to 25 mm 2575 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2576 repair to plaster and plinth protection 2577 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2578 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2579 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2580 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2581 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2582 with cement mortar 1:4 (1cement: 4 coarse sand) 2583 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2584 15mm cement plaster on rough side of single or half brick wall of mix 2585 1:6 (1 cement : 6 course sand) 2586 6mm cement plaster to ceiling of mix : 2587 1:3 ( 1 cement : 3 fine sand) 2588 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2589 two coats 2590 distempering with 1st quality acrylic distemper (ready made) having voc content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 2591 one or more coats on old work 2592 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2593 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2594 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2595 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2596 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2597 repairs to door / windows 2598 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2599 of area 3 sq. metres and below 2600 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2601 of area 3 sq. metres and below 2602 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2603 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2604 renewal of old putty of glass panes (length) 2605 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 2606 35 mm thick including isi marked stainless steel butt hinges with necessary screws 2607 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2608 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete fixed to steel windows by welding 2609 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 2610 300 mm weighing not less than 200gms. 2611 250 mm weighing not less than 150gms. 2612 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 2613 100x58x1.90 mm 2614 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2615 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2616 300 x 10mm 2617 150 x 10mm 2618 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2619 125 mm 2620 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 2621 twin rubber stopper 2622 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 2623 providing and fixing to existing door frames. 2624 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 2625 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 2626 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 2627 with isi marked stainless steel butt hinges of required size 2628 kiln seasoned and chemically treated hollock wood 2629 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 2630 with 12 mm mild steel u beading 2631 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 2632 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2633 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2634 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 2635 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2636 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 2637 4.0 mm thick glass panes 2638 applying priming coat : 2639 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 2640 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2641 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2642 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2643 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2644 one or more coats on old work 2645 repairs to flooring 2646 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2647 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 2648 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 2649 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 2650 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 2651 25 mm thick 2652 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 2653 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 2654 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 2655 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 2656 miscellaneous 2657 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2658 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2659 cement mortar 1:6 (1 cement : 6 coarse sand) 2660 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 2661 cement mortar 1:4 (1 cement :4 coarse sand 2662 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 2663 plumbing work of type-4 2664 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2665 75 to 80 mm dia pipe 2666 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 2667 15 mm to 40 mm nominal bore 2668 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 2669 up to 150 mm diameter 2670 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 2671 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 2672 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 2673 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 2674 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 2675 up to 150 mm diameter 2676 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 2677 rectangular manhole 90x80 cm and 45 cm deep 2678 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2679 110 mm diameter 2680 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2681 a) coupler 2682 110 mm 2683 b) bend 87.5° 2684 110 mm bend 2685 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 2686 75 mm diameter pipes 2687 100 mm diameter pipes 2688 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2689 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 2690 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : 2691 w.c. pan with isi marked white solid plastic seat and lid 2692 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 2693 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 2694 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 2695 kitchen sink without drain board 2696 610x510 mm bowl depth 200 mm 2697 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 2698 a) 32mm dia (for wash basin) 2699 b) 40mm dia (for sink and urinal) 2700 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 2701 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 2702 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 2703 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 2704 providing & fixing c.p. brass waste coupling for pvc waste pipe. 2705 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 2706 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 2707 110 mm dia (wall thickness - 3.2 to 3.8 mm) 2708 75 mm dia (wall thickness - 3.2 to 3.8 mm) 2709 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 2710 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 2711 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 2712 p-trap type floor trap 110 x 75 mm 2713 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 2714 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 2715 providing and fixing 100 mm sand cast iron grating for gully trap. 2716 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 2717 providing & fixing soil, waste and vent pipes. 2718 a) 100mm dia centrifugally cast iron s & s pipe. 2719 b)75mm dia centrifugally cast iron s & s pipe. 2720 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 2721 a) for 100mm dia pipe. 2722 b) for 75mm dia pipe. 2723 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 2724 a) 100mm 2725 sand cast iron s&s as per is - 3989 2726 b) 75mm 2727 sand cast iron s&s as per is- 3989 2728 providing and fixing plaincast iron s & s sanitary bend. 2729 a) 100mm 2730 sand cast iron s&s as per is - 1729 2731 b) 75mm 2732 sand cast iron s&s as per is - 3989 2733 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 2734 a) 100x100x100mm 2735 b) 75x75x75mm 2736 providing and fixingcast iron terminal guard. 2737 a) 100mm 2738 b) 75mm 2739 providing & fixingcast iron coller. 2740 a)100 mm 2741 sand cast iron s&s as per is - 3989 2742 b)75mm dia. 2743 sand cast iron s&s as per is - 3989 2744 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 2745 a) 100mm 2746 b) 75mm 2747 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 2748 a) 100mm inlet & 75mm outlet. 2749 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2750 15 mm nominal outer dia pipes 2751 20 mm nominal outer dia pipes 2752 25 mm nominal outer dia pipes 2753 32 mm nominal outer dia pipes 2754 providing and fixing brass stop cock of approved quality. 2755 15 mm nominal bore 2756 providing and fixing gun metal gate valve with wheel of approved quality. 2757 a) 25mm dia nominal bore 2758 b) 32mm dia nominal bore 2759 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 2760 a) 25mm. nominal bore 2761 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 2762 a) 15mm nominal bore 2763 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 2764 a) 15mm nominal bore 2765 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2766 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2767 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2768 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 2769 providing & fixing cp brass bib cock of approved quality conforming to is 8931 2770 a) 15mm nominal bore 2771 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2772 a) 15mm nominal bore 2773 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 2774 a) 15mm nominal bore 2775 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 2776 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 2777 25mm nominal bore, weighing not less than 62 gms 2778 cutting holes up to 30x30 cm in walls including making good the same: 2779 with common burnt clay f.p.s. (non modular) bricks 2780 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2781 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 2782 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 2783 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 2784 cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer-in-charge. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre) (if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 2785 electrical work of type-4 2786 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2787 group b 2788 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 2789 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 2790 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2791 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2792 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2793 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2794 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2795 group b 2796 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 2797 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2798 2 x 1.5 sq. mm 2799 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2800 25 mm 2801 32 mm 2802 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2803 100 mm x 100 mm x 60 mm deep 2804 150 mm x 75 mm x 60 mm deep 2805 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2806 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2807 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2808 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2809 supplying and fixing brass batten/ angle holder including connection etc. as required. 2810 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2811 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2812 6 way, double door 2813 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2814 4 way (4 + 12), double door 2815 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2816 single pole 2817 single pole and neutral 2818 triple pole 2819 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2820 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2821 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2822 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 2823 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 2824 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2825 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2826 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2827 upto 450 mm sweep 2828 supply of 15w surface mounted round led with all accessories as per standard item.. 2829 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2830 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2831 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2832 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2833 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2834 300 mm sweep 1300 rpm 2835 cost of workshop 2836 repairs to roof 2837 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 2838 asbestos cement sheet 2839 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 2840 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 2841 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin- charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 2842 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 2843 12.5 mm thick tapered edge glass reinforced gypsum (grg) board conforming to is: 2095- (part 3) : 1996 (board with bis certification marks) 2844 repair to plaster and plinth protection 2845 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2846 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2847 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2848 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2849 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2850 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2851 with cement mortar 1:4 (1cement: 4 coarse sand) 2852 12mm cement plaster of mix : 2853 1:6 (1 cement : 6 course sand) 2854 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 2855 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 2856 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2857 old work (one or more coats) 2858 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2859 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2860 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2861 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 2862 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 2863 miscellaneous 2864 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 2865 in cement mortar 2866 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 2867 cement mortar 1:6 (1 cement : 6 coarse sand) 2868 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 2869 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 2870 75 to 80 mm dia pipe 2871 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2872 110 mm diameter 2873 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2874 a) coupler 2875 110 mm 2876 b) bend 87.5° 2877 110 mm bend 2878 electrical cost of workshop 2879 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 2880 group c 2881 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2882 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2883 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 2884 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 2885 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2886 2 x 1.5 sq. mm 2887 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2888 25 mm 2889 32 mm 2890 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2891 100 mm x 100 mm x 60 mm deep 2892 150 mm x 75 mm x 60 mm deep 2893 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2894 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 2895 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2896 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2897 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2898 6 way, double door 2899 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2900 4 way (4 + 12), double door 2901 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2902 single pole 2903 single pole and neutral 2904 triple pole 2905 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 2906 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2907 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2908 upto 450 mm sweep 2909 supply of 15w surface mounted round led with all accessories as per standard item.. 2910 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 2911 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 2912 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 2913 supply of 30w led recess mounted fixturemake-philips cat no.rc380b led30s-6500 l60w60 psd od s1 or equivalent. 2914 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 2915 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 2916 450 mm sweep 1400 rpm 2917 electric sub station 2918 repairs to roof 2919 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2920 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2921 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2922 repair to plaster and plinth protection 2923 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2924 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 2925 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2926 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2927 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2928 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2929 with cement mortar 1:4 (1cement: 4 coarse sand) 2930 12mm cement plaster on rough side of single or half brick wall of mix 2931 1:6 (1 cement : 6 course sand) 2932 6mm cement plaster to ceiling of mix : 2933 1:3 ( 1 cement : 3 fine sand) 2934 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2935 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2936 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 2937 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2938 one or more coats on old work 2939 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2940 two coats 2941 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2942 old work (one or more coats) 2943 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2944 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2945 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2946 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2947 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2948 repairs to door / windows 2949 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2950 of area 3 sq. metres and below 2951 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2952 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2953 renewal of old putty of glass panes (length) 2954 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer. 2955 using flats 30x6mm for diagonal braces and central cross piece 2956 miscellaneous 2957 providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia m.s. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with m.s. tubes, m.s. tube challies, m.s. clamps and m.s. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .the scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of engineerin-charge .the elevational area of the scaffolding shall be measured for payment purpose .the payment will be made once irrespective of duration of scaffolding. note: - this item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 2958 anti-termite treatment 2959 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 2960 110 mm diameter 2961 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 2962 a) coupler 2963 110 mm 2964 b) bend 87.5° 2965 110 mm bend 2966 pump room. 2967 repairs to roof 2968 repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (dr. fixit make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge.with cement mortar 1:4 (1cement: 4 coarse sand) 2969 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 2970 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 2971 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 2972 repair to plaster and plinth protection 2973 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 2974 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 2975 with cement mortar 1:4 (1cement: 4 coarse sand) 2976 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2977 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 2978 15mm cement plaster on rough side of single or half brick wall of mix 2979 1:6 (1 cement : 6 course sand) 2980 6mm cement plaster to ceiling of mix : 2981 1:3 ( 1 cement : 3 fine sand) 2982 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 2983 one or more coats on old work 2984 wall painting with acrylic emulsion paint, having voc (volatile organic compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2985 two coats 2986 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 2987 old work (one or more coats) 2988 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 2989 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 2990 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. 2991 old work (two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 2992 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2993 repairs to door / windows 2994 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 2995 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 2996 renewal of old putty of glass panes (length) 2997 miscellaneous 2998 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 2999 in cement mortar 3000 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 3001 110 mm diameter 3002 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 3003 a) coupler 3004 110 mm 3005 b) bend 87.5° 3006 110 mm bend 3007 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 3008 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 3009 sewerage system 3010 excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 3011 all kinds of soil 3012 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 3013 pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 3014 providing and laying non-pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 3015 150 mm dia. r.c.c. pipe 3016 450 mm dia. r.c.c. pipe 3017 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40 mm nominal size) 3018 150 mm diameter s.w.pipe (l*.35*.10) 3019 450 mm diameter s.w.pipe (l*.6*.15 ) 3020 constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with rcc top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 3021 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 3022 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 3023 extra for depth for manholes: 3024 size 90 x 80 cm 3025 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 3026 constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with fps bricksclass designation 75in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 3027 0.91m deep with sfrc cover and frame (heavy duty hd-20 grade designation) 560mm internal diameter conforming to i.s:12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) 3028 with common burnt clay f.p.s.(non module) brick of class designation 7.5 3029 extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . 3030 with common burnt clay f.p.s.(non module) brick of class designation 7.5 3031 providing and fixing square mouths. w. gully trapclass sp-1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 3032 180 x 150 mm. size p type 3033 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 3034 providing m.s. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 3035 with 20x20 mm square bar 3036 cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 psi for sewer line from 150mm dia upto 300mm 3037 cleaning and desilting of gully trap chamber, including removal ofrubbish mixed with earth etc. and disposal of same, all as per thedirection of engineer-in-charge. 3038 cost of entrance gate 3039 earth work 3040 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.all kinds of soil 3041 extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.all kinds of soil 3042 concrete work 3043 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zoneiii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 3044 providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii): 4 graded stone aggregate 12.5mm nominal size) 3045 providing & applying a coat of residual petroleum bitumen of grade of vg-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 3046 reinforced cement concrete 3047 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 3048 upto plinth level 3049 (i) r.c.c. work in footing 3050 (ii) r.c.c. work in beam 3051 (iii) r.c.c. work in columns 3052 above plinth to floor-v lvl 3053 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 3054 (i) r.c.c. work in beam 3055 (ii) r.c.c. work in columns 3056 (iii) r.c.c. work in slab 3057 centering and shuttering including strutting, propping etc. and removal of form for all heights : 3058 foundations, footings, bases of columns, etc. for mass concrete. 3059 columns,pillars, piers, abutments, posts and struts. 3060 suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 3061 lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 3062 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500d or more. 3063 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. thermo-mechanically treated bars of grade fe-500 d or more. 3064 masonry work 3065 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : cement mortar 1:6 (1 cement : 6 coarse sand) 3066 wood and pvc work 3067 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including isi marked stainless steel butt hinges with necessary screws. 3068 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. fixed to steel windows by welding. 3069 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. twin rubber stopper 3070 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete(a) 125 mm. 3071 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 3072 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 3073 300 x 10mm 3074 200 x 10mm 3075 steel work 3076 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 3077 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 3078 steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 3079 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 3080 flooring 3081 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 3082 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 3083 finishing 3084 12 mm cement plaster on the fair side of single or half brick wall (a) 1:6 (1 cement: 6 coarse sand) 3085 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). 3086 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 3087 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 3088 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work (two or more coats) over and including water thinnable priming coat with cement primer. 3089 finishing walls with water proofing cement paint of required shade : new work (two or more coats applied @ 3.84 kg/10 sqm) 3090 applying priming coat: 3091 with ready mixed aluminium primer of approved brand andmanufacture on resinous wood and plywood 3092 with ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 3093 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 3094 finsihing with epoxy paint (two or more coats) at all locations pepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.on steel work. 3095 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 3096 water proofing 3097 painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 3098 supply & fixing of prepainted coloured trapezoidal or approved profiled sheeting 1000-1020 mm cover width, 28-30 mm high crests with subtle square fluting in the five pan at nominal 190-255 mm (as approved by eic) centre-to-centre manufactured out of 0.50 mm tct hi-tensile prepainted zincalume /galvalume steel (az-150 gsm. aluminium –zinc alloy metallic coating of total both sides 550 mpa yield stress as per as-1397). colour/ exterior coat of rmp 20 micron top coat applied over 5 micron primer and a 5 micron polyester back coat applied over 5 microns primer or equivalent coating/painting. the sheet shall have wide pans with stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlin support. the male end of the sheet shall have anti-capillary flute at side laps to prevent leakages. the sheet shall be fixed by means of anti corrosive approved make rust shield (epoxy polymer) coated self-drilling self tapping fasteners 12-14 x 55 mm with epdm seals through crest for roofing and 12-24 x 20 mm through valley (pans) for wall cladding. the sheet shall be supplied in lengths maximum up to 6-12 meter long to suit site dimensions. the scope includes all sealing of joint, curves, edges or other accessories with silicon sealant. 3099 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 3100 electricalworksmain gate 3101 sub head - i: circuit cum point wiring 3102 switch control light points 3103 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 3104 group c 3105 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required. (switch control secondary points) 3106 group c 3107 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. (switch control primary points) 3108 group c 3109 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutindependent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required. (switch control secondary points) 3110 group c 3111 mcb control light points 3112 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. (switch control primary points) 3113 primary point controlled by one mcb. 3114 same as item above but secondary point. i.e. points to be looped with primary pointwith 2.5 sqmm wire and point wiring 3115 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 3116 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 3117 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 3118 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 3119 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 3120 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 3121 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 3122 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 3123 supplying and fixingsuitable size gi box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 amp modular socket outlet and 5/6 a modular switch, connection etc. as required. 3124 supply and wiringfor 250 volts singlephase and neutral 2 nos 6 amps socket outlate with control by 1 no switched with 2.5 sq.mm pvcinsulatedcopper conductor1100 volts grade stranded flexible frls wires inconcealed or surface mounted 25 mm dia 2mm thickpvc conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick gi box with grid plate and earthingofthird pin of the socket with2.5sq. mm pvc insulated copper conductor strandedflexiblefrlswire.(maximum four no. of switches socket shall be connected on onecircuit) 3125 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 3126 supplying and fixing 63 a, 415 v, tpn industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 3127 supplying and fixing 80 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 3128 supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required. 3129 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 amps modular sp mcb, “c” curve including connection, painting etc. as required. (acs & gysers) 3130 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3131 telephone socket outlet 3132 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 3133 1 or 2 module (75mmx75mm) 3134 6 module (78mm x 205 mm x 50 mm) 3135 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 3136 3 pin , 5/6 amps socket outlet 3137 5/6 amps switch 3138 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 3139 25 mm 3140 32 mm 3141 subhead -ii - fittings & fixtures 3142 supply, installation, testing and commissioning of 10 w bulk head light. 3143 supply, installation, testing and commissioning of 5w mirror light. 3144 supply, installation, testing and commissioning of 18w surface/recessed mounted led circular downlighter. 3145 supply, installation, testing and commissioning of 18/20w wall/surface mouted 4 ft. led 3146 supply, installation, testing and commissioning of 15wsurface mountedled square downlighter. 3147 supply, installation, testing and commissioning of 12/9wrecessed mountedled circular downlighter. 3148 supply, installation, testing and commissioning of9w (nominal)wall bracket light 3149 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019),thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 3150 supplyinstallation, testing and commissioning of 250 mm dia domestic exhaust fan 3151 subhead - iii - distribution boards 3152 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 3153 6 way, double door 3154 8 way, double door 3155 12 way, double door 3156 supplying and fixing following way, three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (but without mcb/ rccb/ isolator) 3157 4 way (4 + 12), double door 3158 6 way (4 + 18), double door 3159 8 way (4 + 24), double door 3160 supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer) as required . (note :vertical type mcb tpdb is normally used where 3 phase outlets are required.) 3161 12 way (4 + 36), double door 3162 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 3163 single pole 3164 single pole neutral 3165 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 3166 40 a 3167 63 a 3168 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 3169 25 a 3170 40 a 3171 63 a 3172 supplying and fixing following rating, double pole, (single phaseand neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 3173 25 a 3174 40 a 3175 63 a 3176 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 3177 basket ball court 3178 for one no. of court 3179 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per directionof engineer - in - charge nominal concrete 1:3:6 or richer mix 3180 providing and laying c.c. pavement of mix m-25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer-incharge. (the panel shuttering work shall be paid for separately). (note:- cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 3181 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 3182 thermo-mechanically treated bars of grade fe-500d or more. 3183 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 3184 40 mm thick with 20 mm nominal size stone aggregate 3185 providing and fixing ac strips in joints ofcement concrete floors.70 mm wide and 4 mm thick. 3186 finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. 3187 on steel work: (on poles) 3188 vertical member (8in dia & 3.2 m long) 3189 horizontal member (8in dia & 2.5 m long) 3190 ugt with pump house 3191 cost of under ground sump 3192 cost of 2 set of 7.5 hp submersible pump (i.e. rs 75,000, each) including all control panel and fitting charges, etc. 3193 external electrical work 3194 subhead - i - main boards 3195 meter boards 3196 supply, installation, testing and commissioning of m.v. cubical type totally enclosed dust, dump and vermin proof meter bords complete with bus bars, mv danger notice plate, on surface isi marked electronic kwh meter, indication lamps, cts, interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingmcbs mccbs and kwh meters complete as required. 3197 panel- kitchen dining 3198 incomer 3199 1 no.40 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3200 metering & indication 3201 1 set of r,y,b phase indicating lamps 3202 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 40/5a cts (40a/500v) rating 3203 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3204 bus-bar 3205 1 set of 50a tpn aluminium bus bar with colour coded pvc sleeves 3206 out going: 3207 2 nos. 25a tpn mcb of 10ka 3208 3 no. 40a dp mcb of 10ka. 3209 supplying,receiving, fixing, testing & commissioning ofabove described panel 3210 meter boards - type-iii, type ii & type i 3211 incomer 3212 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3213 metering & indication 3214 1 set of r,y,b phase indicating lamps 3215 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3216 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3217 bus-bar 3218 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3219 out going: 3220 4 nos. 40a tpn mcb of 10ka 3221 2 nos. 40a dp mcb of 10ka. 3222 supplying,receiving, fixing, testing & commissioning ofabove described panel 3223 meter boards -dormitory boys & girls 3224 incomer 3225 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3226 metering & indication 3227 1 set of r,y,b phase indicating lamps 3228 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3229 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3230 bus-bar 3231 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3232 out going: 3233 4 nos. 40a tpn mcb of 10ka 3234 2 nos. 40a dp mcb of 10ka. 3235 supplying,receiving, fixing, testing & commissioning ofabove described panel 3236 meter boards - vice principle residence, guest house, workshop & gym 3237 1 no.40amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3238 panel -school building & mp hall 3239 incomer 3240 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 3241 metering & indication 3242 1 set of r,y,b phase indicating lamps 3243 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 3244 1 sets of breaker on-off-trip, spring charged indication lamps as required. 3245 bus-bar 3246 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 3247 out going: 3248 4 nos. 40a tpn mcb of 10ka 3249 3 no. 40a dp mcb of 10ka. 3250 supplying,receiving, fixing, testing & commissioning ofabove described panel 3251 subhead - ii - earthing 3252 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 3253 earthing with cu. earth plate 600mm x 600mm x 3mm thick includingaccesssories, and providingmasonary enclosurewith cover plate (ci heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required. 3254 supplying and laying 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode, including connection with g.i. nut, bolt, spring, washer excavation and refilling etc. as required. 3255 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 3256 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 3257 cost of septic tank [for repairing of existing septic tank]
  • View Tender
  • Document
  • Bid Support
10 Municipal Corporation
image image
corporations/Associations/Others
TRN :49062211 |  16 May, 2025
Tender Value : 15.65 Lacs
 Delhi - Delhi
Tender for annual repair maintenance of building in bm-ii division during 2024-25 sh repairing of yashwant place pump room at chanakyapuri new delhi
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • 4
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : pump room
  • Sump Pump Room Tenders ,
  • Pumping House Tenders ,
  • Pump House Tenders ,
  • Pump Chamber Repair Tenders ,
  • Pump Chamber Tenders ,
  • Boosting Station Tenders ,
  • Pump Cabin Tenders ,
  • Water Pump House Tenders ,
  • Pump House Repair Tenders ,
  • Pump Shed Tenders

Get pump room Tender Alert...

224054

Related Searched Keywords : pump room

  • Earth Excavation Tenders From Maharashtra
  • Civil Work Tenders From Delhi
  • Rcc Fencing Tenders From West-Bengal
  • Acoustic Work Tenders From -Tamil-Nadu
  • Desilting Work Tenders From Andhra-Pradesh
  • Flooring Item Tenders From Gujarat
  • Drills Tenders From Karnataka
  • Interlock Paver Tenders From Uttar-Pradesh
  • Tube Well Tenders From Rajasthan
  • Construction Work Tenders From Madhya-Pradesh

Read More


Tender Document

595474

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Excavation Tenders
  • Infrastructure Works Tenders
  • Water Proofing Treatment Work Tenders
  • Bridge Tenders
  • Water Proof Treatment Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App