Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Pvc Block
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of pvc-block Tenders

List of latest pvc-block Tenders in Indian Tenders. Click on any pvc-block Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for pvc-block Tenders.

Advance Search
  • All-Tenders (42)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
21 Panchayat Division
image image
State Government
TRN :34788329 |  18 Jul, 2025
Tender Value : 2.49 Lacs
 South 24 Parganas - West Bengal
Tender for new sinking if 100mm x 40mm dia tubewell with pvc pipe and deep well pump with platform in fornt of tapan sing under dhablat gram panchayat, sagar development block in the district of south 24 parganas sinking of tubewell near ho tapan sing
  • View Tender
  • Document
  • Bid Support
22 Telecommunication Services And Equipments
image image
Central Government And Public Sector
TRN :34776361 |  21 Jul, 2025
Tender Value : 87.99 Lacs
 Nasikcity - Maharashtra
Tender for gem bids for attending complaint of ei fan water pump comp lightlightening conductor substation etc for sites located upto 25km attending complaint of ei fan water pump comp lightlightening conductor substation etc located between 25 kmto 50 km attending complaint of ei fan water pump complight lightening conductor substation etc site locatedbetween 50 km to 100 km attending complaint of ei fanwater pump comp light lightening conductor substation etcfor sites located between 100 km to 200 km s and d of 1 x15 sq mm copper cable in existing steel pvc conduit andcasing capping s and d of 2 x 15 sq mm copper cable inexisting steel pvc conduit and casing capping s and d of 3x 15 sq mm copper cable in existing steel pvc conduit ndcasing caping s and d of 6 x 15 sq mm copper cable inexisting steel pvc conduit and casing capping s and d of 2x 25 sq mm copper cable in existing steel pvc conduit andcasing capping s and d of 3 x 25 sq mm copper cable inexisting steel pvc conduit and casing capping s and d of 6x 25 sq mm copper cable in existing steel pvc conduit andcasing capping s and d of 2 x 4 sq mm copper cable inexisting steel pvc conduit and casing capping s and d of 3x 4 sq mm copper cable in existing steel pvc conduit andcasing capping s and d of 6 x 4 sq mm copper cable inexisting steel pvc conduit and casing caping s and d of 2 x6 sq mm copper cable in existing steel pvc conduit andcasing caping s and d of 3 x 6 sq mm copper cable inexisting steel pvc conduit and casing caping circuit orsubmain wiring with 2 x 15 sq mm plus 1 x 15 sq mm circuit or submain wiring with 2 x 25 sq mm plus 1 x 25 sqmm circuit or submain wiring with 2 x 4 sq mm plus 1 x 4sq mm s and f of 20 mm medium class pvc conduitsurface or recess s and f of 25 mm medium class pvcconduit surface or recess s and f of 32 mm medium class bid number gem2025b6394889 dated 28-06-2025 bid document1 138 pvc conduit surface or recess providing and fixing 20 mmx 12 mm casing capping providing and fixing 25 mm x 16mm casing capping providing and fixing 32 mm x 16 mmcasing capping s and f metal box of sizes 75 mm x 75 mmx 60 mm on surface or in recess s and f metal box of sizes150 mm x 75 mm x 60 mm on surface or in recess s and fmetal box of sizes 180 mm x 100 mm x 60 mm on surfaceor in recess supplying and fixing 1 or 2 module75mmx75mm gi box in recess supplying and fixing 3module 100mm x 75mm gi box in recess supplying andfixing 4 module 125mm x 75mm gi box in recess supplying and fixing 6 module 200 mm x 75mm gi box inrecess supplying and fixing 8 module 125 mm x 125 gibox in recess supplying and fixing 12 module 200 mm x150 gi box in recess supplying and fixing 1 or 2 modulemodular base and cover plate supplying and fixing 3module modular base and cover plate supplying and fixing4 module modular base and cover plate supplying andfixing 6 module modular base and cover plate supplyingand fixing 8 module modular base and cover plate supplying and fixing 12 module modular base and coverplate replacement with 5 or 6 amp switch piano type replacement with 2 way 5 or 6 amps switch piano type replacement with 15 or 16 amp switch piano type replacement with 3 pin 5 or 6 amp socket outlet piano type replacement with 6 pin 15 or 16 amp socket outlet pianotype replacement with telephone socket outlet pianotype replacement with tv antenna socket outlet pianotype replacement with bell push piano type replacement with electronic fan regulator 100 watt steptype etc replacement with 5 or 6 amps switch modulartype replacement with 2 way 5 or 6 amps switch modulartype replacement with 15 or 16 amp switch modular type replacement with 3 pin 5 or 6 amp socket outlet modulartype replacement with 6 pin 15 or 16 amp socket outletmodular type replacement with telephone socket outletmodular type replacement with tv antenna socket outlettype replacement with bell push modular type replacement with two module stepped type electronic fanregulator replacement with supplying and fixing 3 pin 5amp ceiling rose replacement with supplying and fixingbrass batten or angle holder replacement with supplyingand fixing call bell or buzzer replacement of faultyflurescent tube light starter 0 to 40 watt 220 to 240 v ac replacement with supplying and fixing of 5 a to 32a ratingsingle pole mcb replacement with supplying and fixing of5 a to 32a rating spn mcb replacement with supplyingand fixing of 5a to 32a rating dp mcb replacement withsupplying and fixing of 5 a to 32a rating tp mcb replacement with supplying and fixing of 5 a to 32a ratingtpn mcb replacement with supplying and fixing of 40amps 4 pole 415 volts isolator replacement with supplyingand fixing of 63 amps 4 pole 415 volts isolator replacement with supplying and fixing of 100 amp 4 pole415 volts isolator replacement with supplying and fixingof 40 amps sp and n rccb supplying and fixing with ledtype tube light fitting 20 to 28 watt rewinding of ceilingfan upto 1400 mm sweep rewinding of wall fan upto 450mm sweep rewinding of exhaust fan upto 450 mm sweep rewinding of pedestal fan upto 450 mm sweep supplyingand fixing high performance of 45 watts led street light supplying and fixing 38mm dia gi pipe 09 mtr lengthbracket replacement of pole junction box with supplyingand fixing of 240 mm x 130mm x 100 mm size of frp bid details2 138 1 1 providing and fixing of lightning conductor finial., jointingcopper or g.i. tape with another copper or g i tape, providing and fixing g.i. tape 20 mm x 3 mm thick onparapet or surface of wall, providing and fixing 25 mm x 5mm g.i. strip on surface or in recess, repairing rewindingof 1 hp capacity centrifugal pump, repairing rewinding of 2hp capacity centrifugal pump, repairing rewinding of 3 hpcapacity centrifugal pump set, repairin rewinding of 5 hpcapacity centrifugal pump set, repairing rewinding of 1.5hp capacity submersible pumpset, repairing rewinding of 2hp capacity submersible pumpset, repairing rewinding of 3hp capacity submersible pumpset, repairing rewinding of 5hp capacity submersible pumpset, sitc of submersiblepumpset of 2 hp water filled, sitc of submersible pumpsetof 4 hp water filled, lifting and lowing of submersible orborewell pump upto 5 hp alongwith gi pipe, lifting andlowing of submersible or borewell pump upto 5 hpalongwith hdpe pipe, repairing rewinding of 2 hp sumppump set, repairing rewinding of 3 hp sump pump set, repairing rewinding of 5 hp sump pump, replacement offaulty foot valve of size 40 mm dia, replacement of faultyfoot valve of size 50 mm dia, replacement faulty gatevalve with brass forged or gun metal valve of 20 mm dia, replacement faulty gate valve with brass forged or gunmetal valve of 40 mm dia, replacement faulty gate valvewith brass forged or gun metal valve of 50 mm dia, replacement of nrv with new nrv made up of brass of size40 mm dia, replacement of nrv with new nrv made up ofbrass of size 50 mm dia, supplying and fixing 20 mm dia bclass medium g.i pipe, supplying and fixing 40 mm dia bclass medium g.i pipe, supplying and fixing 50 mm dia bclass medium g.i pipe, supplying and fixing 20 mm diaheavy duty upvc pipe, supplying and fixing 40 mm diaheavy duty upvc pipe, supplying and fixing 50 mm diaheavy duty upvc pipe, replacement 3 pole powercontactors type mnx 12, replacement 3 pole powercontactors type mnx22, replacement of mounting add onaux. contact block suitable for 9 a to 30 a, replacement ofthermal overload relay suitable for mnx contactor rangefrom 0.2 a to 23 a, supplying of 3 x 2.5 sq. mm aluminumconductor cable of 1.1kv grade, supplying of 4 x 16 sq. mmaluminum conductor cable of 1.1kv grade, supplying of 3.5x 35 sq. mm aluminum conductor cable of 1.1kv grade, laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm direct in ground, laying of one no. cable of 1.1 kvgrade and size above 35 upto 95 sq. mm direct in ground, laying of one no. cable of 1.1 kv grade and size above 95upto 185 sq. mm direct in ground, laying of one no. cableof 1.1 kv grade and size upto 35 sq.mm on cable tray, laying of one no. cable of 1.1 kv grade and size above 35upto 95 sq. mm on cable tray, laying of one no. cable of1.1 kv grade and size above 95 upto 185 sq. mm on cabletray, laying of one no. cable of 1.1 kv grade and size upto35 sq. mm in existing rcc or hume or metal pipe, layingof one no. cable of 1.1 kv grade and size above 35 upto 95sq. mm in existing rcc or hume or metal pipe, laying ofone no. cable of 1.1 kv grade and size above 95 upto 185sq. mm in existing rcc or hume or metal pipe, laying ofone no. cable of 1.1 kv grade and size upto 35 sq. mm inexisting masonry open duct, laying of one no. cable of 1.1kv grade and size above 35 upto 95 sq. mm in existingmasonry open duct, laying of one no. cable of 1.1 kv gradeand size above 95 upto 185 sq. mm in existing masonryopen duct, laying of one no. cable of 1.1 kv grade and size    //bid details3 / 138 upto 35 sq. mm on wall surface, laying of one no. cable of1.1 kv grade and size above 35 upto 95 sq. mm on wallsurface, laying of one no. cable of 1.1 kv grade and sizeabove 95 upto 185 sq. mm on wall surface, s and m endtermination with brass compression gland and aluminiumlugs for 2 x 6 sq.mm al cable., s and m end terminationwith brass compression gland and aluminium lugs for 2 x 10sq.mm al cable., s and m end termination with brasscompression gland and aluminium lugs for 2 x 16 sq.mm alcable., s and m end termination with brass compressiongland and aluminium lugs for 2 x 25 sq.mm al cable., s andm end termination with brass compression gland andaluminium lugs for 3 x 16 sq.mm al cable., s and m endtermination with brass compression gland and aluminiumlugs for 3.5 x 25 sq. mm al cable., s and m end terminationwith brass compression gland and aluminium lugs for 3.5 x35 sq. mm al cable., s and m end termination with brasscompression gland and aluminium lugs for 3.5 x 50 sq. mmal cable., s and m end termination with brass compressiongland and aluminium lugs for 3.5 x 70 sq. mm al cable., sand m end termination with brass compression gland andaluminium lugs for 3.5 x 95 sq. mm al cable., s and m endtermination with brass compression gland and aluminiumlugs for 3.5 x 120 sq. mm al cable., s and m endtermination with brass compression gland and aluminiumlugs for 3.5 x 150 sq. mm al cable., s and m endtermination with brass compression gland and aluminiumlugs for 3.5 x 185 sq. mm al cable., replacement of burntout aluminium lugs for 2 x 6 sq.mm aluminium conductorcable., replacement of burnt out aluminium lugs for 2 x 10sq.mm aluminium conductor cable., replacement of burntout aluminium lugs for 2 x 16 sq.mm aluminium conductorcable., replacement of burnt out aluminium lugs for 2 x 25sq.mm aluminium conductor cable., replacement of burntout aluminium lugs for 3 x 16 sq.mm aluminium conductorcable., replacement of burnt out aluminium lugs for 3.5 x25 sq.mm aluminium conductor cable., replacement ofburnt out aluminium lugs for 3.5 x 35 sq.mm aluminiumconductor cable., replacement of burnt out aluminium lugsfor 3.5 x 50 sq.mm aluminium conductor cable., replacement of burnt out aluminium lugs for 3.5 x 70sq.mm aluminium conductor cable., replacement of burntout aluminium lugs for 3.5 x 95 sq.mm aluminiumconductor cable., replacement of burnt out aluminium lugsfor 3.5 x 120 sq.mm aluminium conductor cable., replacement of burnt out aluminium lugs for 3.5 x 150sq.mm aluminium conductor cable., replacement of burntout aluminium lugs for 3.5 x 185 sq.mm aluminiumconductor cable., connection with copper link with 10 sq.mm single core frls copper pvc insulated flexible cable, connection with copper link with 16 sq. mm single coreflexible cable ., connection with copper link with 25 sq. mmsingle core flexible cable ., connection with copper linkwith 35 sq. mm single core flexible cable ., connectionwith copper link with 50 sq. mm single core flexible cable ., providing and fixing 6 swg dia g.i. wire on surface or inrecess, replacement of faulty la polymer or porcelien typefor overhead 11.0 kv line, repalcement of faulty acsrconductor approx length 1mtr, replacement of faulty 11kv pin insulator, replacement of faulty 11 kv disc insulator, replacement of 11.0 kv air break gang operated switchsingle pole, replacement of 11.0 kv air break gangoperated switch 3 pole, replacment of faulty or burnt out11.0 kv do fuse complete units of three phase.,     //bid details4 / 138 replacment of faulty or burnt out 11.0 kv do fuse units forindividual phase, replacement of silica gel crystal, refillingof existing 4.5 kg co2 type fire extinguishers, replacementfaulty r y and g indication lamp, replacement faulty blueindication lamp, replacement of faulty on load changeoveror switch disconector 63 a, replacement of faulty on loadchangeover or switch disconector 125 a, replacement offaulty fn 63 tpn or fp range 0 to 63 a sdf units, replacement of faulty fn 125 tpn range 63a to 125a sdfunits, replacement of fused out or faulty cylindrical hrcfuse links of rating 2a to 32 a, replacement cylindrical hrcfuse links of rating 40 a suitable for type fn 63. fnx 63 sdfand hc 63 fuse base, replacement cylindrical hrc fuselinks of rating 60 a suitable for type fn 63 fnx 63 sdf andfor hc 63 fuse base, replacement of cylindrical hrc fuselinks of rating 63 a suitable hn suitable for type fn 100 fn125 fn160 fnx 100 fnx 125 fnx 160 sdf etc, replacement cylindrical hrc fuse links of rating 100 asuitable hn suitable for type fn 100 fn 125 fn160 fnx100 fnx 125 fnx 160 sdf etc, replacement cylindricalhrc fuse links of rating 125 a suitable hn suitable for typefn 100 fn 125 fn160 fnx 100 fnx 125 fnx 160 sdf etc
  • View Tender
  • Document
  • Bid Support
23 Telecommunication Services And Equipments
image image
Central Government And Public Sector
TRN :34776587 |  21 Jul, 2025
Tender Value : 87.99 Lacs
 Nagpur - Maharashtra
Tender for gem bids for attending complaint of ei fan water pump comp lightlightening conductor substation etc for sites located upto 25km attending complaint of ei fan water pump comp lightlightening conductor substation etc located between 25 kmto 50 km attending complaint of ei fan water pump complight lightening conductor substation etc site locatedbetween 50 km to 100 km attending complaint of ei fanwater pump comp light lightening conductor substation etcfor sites located between 100 km to 200 km s and d of 1 x15 sq mm copper cable in existing steel pvc conduit andcasing capping s and d of 2 x 15 sq mm copper cable inexisting steel pvc conduit and casing capping s and d of 3x 15 sq mm copper cable in existing steel pvc conduit ndcasing caping s and d of 6 x 15 sq mm copper cable inexisting steel pvc conduit and casing capping s and d of 2x 25 sq mm copper cable in existing steel pvc conduit andcasing capping s and d of 3 x 25 sq mm copper cable inexisting steel pvc conduit and casing capping s and d of 6x 25 sq mm copper cable in existing steel pvc conduit andcasing capping s and d of 2 x 4 sq mm copper cable inexisting steel pvc conduit and casing capping s and d of 3x 4 sq mm copper cable in existing steel pvc conduit andcasing capping s and d of 6 x 4 sq mm copper cable inexisting steel pvc conduit and casing caping s and d of 2 x6 sq mm copper cable in existing steel pvc conduit andcasing caping s and d of 3 x 6 sq mm copper cable inexisting steel pvc conduit and casing caping circuit orsubmain wiring with 2 x 15 sq mm plus 1 x 15 sq mm circuit or submain wiring with 2 x 25 sq mm plus 1 x 25 sqmm circuit or submain wiring with 2 x 4 sq mm plus 1 x 4sq mm s and f of 20 mm medium class pvc conduitsurface or recess s and f of 25 mm medium class pvcconduit surface or recess s and f of 32 mm medium class bid number gem2025b6395260 dated 28-06-2025 bid document1 138 pvc conduit surface or recess providing and fixing 20 mmx 12 mm casing capping providing and fixing 25 mm x 16mm casing capping providing and fixing 32 mm x 16 mmcasing capping s and f metal box of sizes 75 mm x 75 mmx 60 mm on surface or in recess s and f metal box of sizes150 mm x 75 mm x 60 mm on surface or in recess s and fmetal box of sizes 180 mm x 100 mm x 60 mm on surfaceor in recess supplying and fixing 1 or 2 module75mmx75mm gi box in recess supplying and fixing 3module 100mm x 75mm gi box in recess supplying andfixing 4 module 125mm x 75mm gi box in recess supplying and fixing 6 module 200 mm x 75mm gi box inrecess supplying and fixing 8 module 125 mm x 125 gibox in recess supplying and fixing 12 module 200 mm x150 gi box in recess supplying and fixing 1 or 2 modulemodular base and cover plate supplying and fixing 3module modular base and cover plate supplying and fixing4 module modular base and cover plate supplying andfixing 6 module modular base and cover plate supplyingand fixing 8 module modular base and cover plate supplying and fixing 12 module modular base and coverplate replacement with 5 or 6 amp switch piano type replacement with 2 way 5 or 6 amps switch piano type replacement with 15 or 16 amp switch piano type replacement with 3 pin 5 or 6 amp socket outlet piano type replacement with 6 pin 15 or 16 amp socket outlet pianotype replacement with telephone socket outlet pianotype replacement with tv antenna socket outlet pianotype replacement with bell push piano type replacement with electronic fan regulator 100 watt steptype etc replacement with 5 or 6 amps switch modulartype replacement with 2 way 5 or 6 amps switch modulartype replacement with 15 or 16 amp switch modular type replacement with 3 pin 5 or 6 amp socket outlet modulartype replacement with 6 pin 15 or 16 amp socket outletmodular type replacement with telephone socket outletmodular type replacement with tv antenna socket outlettype replacement with bell push modular type replacement with two module stepped type electronic fanregulator replacement with supplying and fixing 3 pin 5amp ceiling rose replacement with supplying and fixingbrass batten or angle holder replacement with supplyingand fixing call bell or buzzer replacement of faultyflurescent tube light starter 0 to 40 watt 220 to 240 v ac replacement with supplying and fixing of 5 a to 32a ratingsingle pole mcb replacement with supplying and fixing of5 a to 32a rating spn mcb replacement with supplyingand fixing of 5a to 32a rating dp mcb replacement withsupplying and fixing of 5 a to 32a rating tp mcb replacement with supplying and fixing of 5 a to 32a ratingtpn mcb replacement with supplying and fixing of 40amps 4 pole 415 volts isolator replacement with supplyingand fixing of 63 amps 4 pole 415 volts isolator replacement with supplying and fixing of 100 amp 4 pole415 volts isolator replacement with supplying and fixingof 40 amps sp and n rccb supplying and fixing with ledtype tube light fitting 20 to 28 watt rewinding of ceilingfan upto 1400 mm sweep rewinding of wall fan upto 450mm sweep rewinding of exhaust fan upto 450 mm sweep rewinding of pedestal fan upto 450 mm sweep supplyingand fixing high performance of 45 watts led street light supplying and fixing 38mm dia gi pipe 09 mtr lengthbracket replacement of pole junction box with supplyingand fixing of 240 mm x 130mm x 100 mm size of frp bid details2 138 1 1 providing and fixing of lightning conductor finial., jointingcopper or g.i. tape with another copper or g i tape, providing and fixing g.i. tape 20 mm x 3 mm thick onparapet or surface of wall, providing and fixing 25 mm x 5mm g.i. strip on surface or in recess, repairing rewindingof 1 hp capacity centrifugal pump, repairing rewinding of 2hp capacity centrifugal pump, repairing rewinding of 3 hpcapacity centrifugal pump set, repairin rewinding of 5 hpcapacity centrifugal pump set, repairing rewinding of 1.5hp capacity submersible pumpset, repairing rewinding of 2hp capacity submersible pumpset, repairing rewinding of 3hp capacity submersible pumpset, repairing rewinding of 5hp capacity submersible pumpset, sitc of submersiblepumpset of 2 hp water filled, sitc of submersible pumpsetof 4 hp water filled, lifting and lowing of submersible orborewell pump upto 5 hp alongwith gi pipe, lifting andlowing of submersible or borewell pump upto 5 hpalongwith hdpe pipe, repairing rewinding of 2 hp sumppump set, repairing rewinding of 3 hp sump pump set, repairing rewinding of 5 hp sump pump, replacement offaulty foot valve of size 40 mm dia, replacement of faultyfoot valve of size 50 mm dia, replacement faulty gatevalve with brass forged or gun metal valve of 20 mm dia, replacement faulty gate valve with brass forged or gunmetal valve of 40 mm dia, replacement faulty gate valvewith brass forged or gun metal valve of 50 mm dia, replacement of nrv with new nrv made up of brass of size40 mm dia, replacement of nrv with new nrv made up ofbrass of size 50 mm dia, supplying and fixing 20 mm dia bclass medium g.i pipe, supplying and fixing 40 mm dia bclass medium g.i pipe, supplying and fixing 50 mm dia bclass medium g.i pipe, supplying and fixing 20 mm diaheavy duty upvc pipe, supplying and fixing 40 mm diaheavy duty upvc pipe, supplying and fixing 50 mm diaheavy duty upvc pipe, replacement 3 pole powercontactors type mnx 12, replacement 3 pole powercontactors type mnx22, replacement of mounting add onaux. contact block suitable for 9 a to 30 a, replacement ofthermal overload relay suitable for mnx contactor rangefrom 0.2 a to 23 a, supplying of 3 x 2.5 sq. mm aluminumconductor cable of 1.1kv grade, supplying of 4 x 16 sq. mmaluminum conductor cable of 1.1kv grade, supplying of 3.5x 35 sq. mm aluminum conductor cable of 1.1kv grade, laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm direct in ground, laying of one no. cable of 1.1 kvgrade and size above 35 upto 95 sq. mm direct in ground, laying of one no. cable of 1.1 kv grade and size above 95upto 185 sq. mm direct in ground, laying of one no. cableof 1.1 kv grade and size upto 35 sq.mm on cable tray, laying of one no. cable of 1.1 kv grade and size above 35upto 95 sq. mm on cable tray, laying of one no. cable of1.1 kv grade and size above 95 upto 185 sq. mm on cabletray, laying of one no. cable of 1.1 kv grade and size upto35 sq. mm in existing rcc or hume or metal pipe, layingof one no. cable of 1.1 kv grade and size above 35 upto 95sq. mm in existing rcc or hume or metal pipe, laying ofone no. cable of 1.1 kv grade and size above 95 upto 185sq. mm in existing rcc or hume or metal pipe, laying ofone no. cable of 1.1 kv grade and size upto 35 sq. mm inexisting masonry open duct, laying of one no. cable of 1.1kv grade and size above 35 upto 95 sq. mm in existingmasonry open duct, laying of one no. cable of 1.1 kv gradeand size above 95 upto 185 sq. mm in existing masonryopen duct, laying of one no. cable of 1.1 kv grade and size    //bid details3 / 138 upto 35 sq. mm on wall surface, laying of one no. cable of1.1 kv grade and size above 35 upto 95 sq. mm on wallsurface, laying of one no. cable of 1.1 kv grade and sizeabove 95 upto 185 sq. mm on wall surface, s and m endtermination with brass compression gland and aluminiumlugs for 2 x 6 sq.mm al cable., s and m end terminationwith brass compression gland and aluminium lugs for 2 x 10sq.mm al cable., s and m end termination with brasscompression gland and aluminium lugs for 2 x 16 sq.mm alcable., s and m end termination with brass compressiongland and aluminium lugs for 2 x 25 sq.mm al cable., s andm end termination with brass compression gland andaluminium lugs for 3 x 16 sq.mm al cable., s and m endtermination with brass compression gland and aluminiumlugs for 3.5 x 25 sq. mm al cable., s and m end terminationwith brass compression gland and aluminium lugs for 3.5 x35 sq. mm al cable., s and m end termination with brasscompression gland and aluminium lugs for 3.5 x 50 sq. mmal cable., s and m end termination with brass compressiongland and aluminium lugs for 3.5 x 70 sq. mm al cable., sand m end termination with brass compression gland andaluminium lugs for 3.5 x 95 sq. mm al cable., s and m endtermination with brass compression gland and aluminiumlugs for 3.5 x 120 sq. mm al cable., s and m endtermination with brass compression gland and aluminiumlugs for 3.5 x 150 sq. mm al cable., s and m endtermination with brass compression gland and aluminiumlugs for 3.5 x 185 sq. mm al cable., replacement of burntout aluminium lugs for 2 x 6 sq.mm aluminium conductorcable., replacement of burnt out aluminium lugs for 2 x 10sq.mm aluminium conductor cable., replacement of burntout aluminium lugs for 2 x 16 sq.mm aluminium conductorcable., replacement of burnt out aluminium lugs for 2 x 25sq.mm aluminium conductor cable., replacement of burntout aluminium lugs for 3 x 16 sq.mm aluminium conductorcable., replacement of burnt out aluminium lugs for 3.5 x25 sq.mm aluminium conductor cable., replacement ofburnt out aluminium lugs for 3.5 x 35 sq.mm aluminiumconductor cable., replacement of burnt out aluminium lugsfor 3.5 x 50 sq.mm aluminium conductor cable., replacement of burnt out aluminium lugs for 3.5 x 70sq.mm aluminium conductor cable., replacement of burntout aluminium lugs for 3.5 x 95 sq.mm aluminiumconductor cable., replacement of burnt out aluminium lugsfor 3.5 x 120 sq.mm aluminium conductor cable., replacement of burnt out aluminium lugs for 3.5 x 150sq.mm aluminium conductor cable., replacement of burntout aluminium lugs for 3.5 x 185 sq.mm aluminiumconductor cable., connection with copper link with 10 sq.mm single core frls copper pvc insulated flexible cable, connection with copper link with 16 sq. mm single coreflexible cable ., connection with copper link with 25 sq. mmsingle core flexible cable ., connection with copper linkwith 35 sq. mm single core flexible cable ., connectionwith copper link with 50 sq. mm single core flexible cable ., providing and fixing 6 swg dia g.i. wire on surface or inrecess, replacement of faulty la polymer or porcelien typefor overhead 11.0 kv line, repalcement of faulty acsrconductor approx length 1mtr, replacement of faulty 11kv pin insulator, replacement of faulty 11 kv disc insulator, replacement of 11.0 kv air break gang operated switchsingle pole, replacement of 11.0 kv air break gangoperated switch 3 pole, replacment of faulty or burnt out11.0 kv do fuse complete units of three phase.,     //bid details4 / 138 replacment of faulty or burnt out 11.0 kv do fuse units forindividual phase, replacement of silica gel crystal, refillingof existing 4.5 kg co2 type fire extinguishers, replacementfaulty r y and g indication lamp, replacement faulty blueindication lamp, replacement of faulty on load changeoveror switch disconector 63 a, replacement of faulty on loadchangeover or switch disconector 125 a, replacement offaulty fn 63 tpn or fp range 0 to 63 a sdf units, replacement of faulty fn 125 tpn range 63a to 125a sdfunits, replacement of fused out or faulty cylindrical hrcfuse links of rating 2a to 32 a, replacement cylindrical hrcfuse links of rating 40 a suitable for type fn 63. fnx 63 sdfand hc 63 fuse base, replacement cylindrical hrc fuselinks of rating 60 a suitable for type fn 63 fnx 63 sdf andfor hc 63 fuse base, replacement of cylindrical hrc fuselinks of rating 63 a suitable hn suitable for type fn 100 fn125 fn160 fnx 100 fnx 125 fnx 160 sdf etc, replacement cylindrical hrc fuse links of rating 100 asuitable hn suitable for type fn 100 fn 125 fn160 fnx100 fnx 125 fnx 160 sdf etc, replacement cylindricalhrc fuse links of rating 125 a suitable hn suitable for typefn 100 fn 125 fn160 fnx 100 fnx 125 fnx 160 sdf etc
  • View Tender
  • Document
  • Bid Support
24 Security Services
image image
Central Government/Public Sector
TRN :34776668 |  19 Jul, 2025
Tender Value : 0
 Agra - Uttar Pradesh
Tender for gem bids for de spanner 12x13, adjustable spanner8, cutting plier, tool kit bag canvas, screw driver 12 300mm, screwdriver 8, first aid kit, ring spanner 10 x 11, ring spanner12 x 13, ring spanner 18 x 19, phil screw driver 100mmlong 6 dia, tube hose pump, chassis record beg, assywheel nut m 20 x 2.5, screw driver, rubber packing, single filament fhl 12v, bush engine cleaning, rubberhose radiator to thermostate, rubber hose, scabbarddah mk-3, bock wooden for jack, chock large, tinrectangular 5 ltrs, ms fabricated parking chock, push tapss, assy spacer block complete, tyre lever t l6, handlamp with cable of length 10mm, adjusting screw, foglight 12v, bulb f 15 w for rear indicator, bulb 12v forfront indicator, block jack, box tin lamp filament, bulb12 3 21 6 for stop lamp, funnel oil 152mm oval, inserterand remover tyre valve, philps head screwdriver 100mmlongtip, de spanner 5 8 x 9 16 sae, de spanner 14 x15mm, tool box, bulb turn signal 12v and 21w, jack withhandle 12ton, pvc hose nipple, sump packing, rubberpacking main hole cover, de spanner 11 x 13, chocksstowage vehicle timber, inspection lamp with 10 mrs longtable
  • View Tender
  • Document
  • Bid Support
25 Services
image image
Central Government/Public Sector
TRN :34765683 |  23 Jul, 2025
Tender Value : 0
 Kamrup - Assam
Tender for gem bids for usb ptz camera, 4 channel hd switcher, hdmi to usbconverter, 22 inchtouch monitor, ceiling mount bracket, item 6 extender, 4k 18gbps hdmi splitter, item 8 switcher, 1 into 4 hdmi splitter, hdmi to hdmi cable length 1m, hdmi to hdmi cable l 15m, hdmi to hdmi cable length 5m, hdmi to hdmi cable length 2m, usb cable length15m, usb hub, 55 inch display, 65 inch display, 24 inch touchmonitor, stereo headphone amplifier, headphone, microphone, aio pc, scanner, landline phone, zoomdocument camera, 8 port network switch, cat6 utpcables, 25mm pvc casing caping, audio signal cable, xlr terminal block phone jack ep jack, 1.5sqmm 3 corecopper electrical cable, electrical switch socket mcb, manpower for 1 year, site preparation
  • View Tender
  • Document
  • Bid Support
26 Security Services
image image
Central Government/Public Sector
TRN :34767257 |  23 Jul, 2025
Tender Value : 0
 Allahabad - Uttar Pradesh
Tender for gem bids for cement opc 43 grade in hdpe bag of 50 kg each, naturalsand, aggregate 20mm, aggregate 40mm, hollow blocksof size 600mmx200mmx200mm, water proofing compound, ms tmt bar of size 8mm dia, ms tmt bar of size 10mmdia, ms tmt bar of size 12mm dia, pvc pipe of size 12inchdia, pvc pipe of size 8inch dia, pvc pipe of size 6inch dia, pvc pipe of size 4inch dia, pvc elbow of size 6inch dia, pvc tee of size 6inch dia, pvc tee of size 4inch dia, pvcelbow reducer of size 8inch to 6inch, pvc tee reducer ofsize inch to 6inch, pvc adhesive pipe fitting solution, msbinding wire not less than 0.9mm dia, 12mm dia plywood ofsize 2.5x0.3m, frp green transparent sheet, ms squarehollow section of size 50x50x3.00mm, self taping screw3inch long, nails 2inch, welding rod, aenerobic bacteriafor septic tank
  • View Tender
  • Document
  • Bid Support
27 Recreational Services
image image
Central Government/Public Sector
TRN :34769490 |  23 Jul, 2025
Tender Value : 19.20 Lacs
 Imphal - Manipur
Tender for gem bids for renovation, pcr property store renovation, pvc pipe line for d type qtrand office, new equipment rack stand for ces, officeblock lighting renovation, property room renovationpainting vitrified tiles flooring works gupsump ceiling work, main studio walls renovation painting work, studio blocklighting replacement work, artist make up room cupboardreplacement with mdf ply, new aluminium glass windowsfor property store make up room
  • View Tender
  • Document
  • Bid Support
28 Security Services
image image
Central Government/Public Sector
TRN :34769855 |  24 Jul, 2025
Tender Value : 0
 Kutch - Gujarat
Tender for gem bids for pvc exhaust fan 250 mm, tamper proof energy meter 2080 amps three phase, flame proof tube light 2 x 40w, flame proof exhaust fan 380mm, modular switch 5 a, modular socket 15 amp, fan regulator stepped type, socket 15 amp, piano switch 15 amp, piano switch 5 amp, modular switch 15 a, socket 5 amp, plug top 15 amp, plug top 05 amp, ac box with mcb 20 amp, flame prooftube light 1 x 20 w with fitting, water tank cover, plywoodcommercial gold 8f x 4f x 6mm, plywood commercial gold8f x 4f x 19 mm, beenear, plywood commercial gold 8f x4f x 4mm, plywood one side teak face of size 8fx4fx12mm, plywood one side teak face of size 8fx4fx6mm, blockboard grade 2 quality type 18 oblique 19mm thick
  • View Tender
  • Document
  • Bid Support
29 Coal And Lignite
image image
Central Government/Public Sector
TRN :34770471 |  23 Jul, 2025
Tender Value : 0
 Burdwan - West Bengal
Tender for gem bids for procurement, pvc, heavy duty suction discharge helical water hose size 3inch, pvc, heavy duty suction discharge helical water hosesize 6 inch, canvas fire fighting hose, size 3 inch, safetyslogan board, retro reflective, size 12 inch x 12 inch, safety slogan board, retro reflective, size 12 inch x 24 inch, hyd jack 50ton complete set with all accessories, alcoholmeter, hard wood wooden block, size 8 inch x 8 inch x 2inch, heavy duty 30lbs jims crow, blanket, fire, 5ftx6ft, leather hand gloves, 12inch long, rubber spray hose, id19mm, pu coated hand gloves
  • View Tender
  • Document
  • Bid Support
30 Construction
image image
State Government
TRN :34760739 |  21 Jul, 2025
Tender Value : 48.51 Lacs
 Jirania - Tripura
Tender for retrofitting of water supply scheme under jjm extension of pipe line at diff locations under mandwi r.d. block. s.h./ providing laying of pvc, gi di pipe line, constr. of sluice valve chamber, providing fhtc and other related work etc. gr.-i
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • 4
  • 5
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : pvc block
  • Pvc Wallet Tenders ,
  • Pvc Separator Tenders ,
  • Pvc Door Frame Tenders ,
  • Pvc Item Tenders ,
  • Pvc Cover Tenders ,
  • Pvc Gutter Tenders ,
  • Pvc Blind Tenders ,
  • Pvc Sleeving Tenders ,
  • Pvc Tale Tenders ,
  • Pvc Plate Tenders

Get pvc block Tender Alert...

462447

Related Searched Keywords : pvc block

  • Culvert Wall Tenders From Maharashtra
  • Civil Engineering Tenders From Delhi
  • Water Proofing Treatment Tenders From West-Bengal
  • Drainage Tenders From -Tamil-Nadu
  • Pit Work Tenders From Andhra-Pradesh
  • Building Work Tenders From Gujarat
  • False Ceiling Work Tenders From Karnataka
  • Subways Tenders From Uttar-Pradesh
  • Zone Work Tenders From Rajasthan
  • Excavating Tenders From Madhya-Pradesh

Read More


Tender Document

100127

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Land Levelling Tenders
  • False Celling Tenders
  • Lift Irrigation Service Tenders
  • Infrastructures Work Tenders
  • Tiles Work Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App