faricating and installing safety hand railing at wwtp monitoring asin pits. site image attached in pr record. contact person : dipesh kumar chauhan 0522456862 dipesh.chauhan@dewa.gov.ae, faricating and installing chequered plate covers at wwtp monitoring asin pit . site image attached in pr record. contact person : dip esh kumar chauhan 0522456862 dipesh.chauhan@dewa.gov.ae, faricating and installing chequered plate covers at stp pit . site image attached in pr record. contact person : dipesh kumar chauhan 0522456862 dipesh.chauhan@dewa.gov.ae
scope and requirements: location: dip1 pumping station monthly amc-pm for tamco medium voltage switchgear, l and t low voltage switchge ar and its auxiliaries including capacitor ank, protection relays, vts, cts etc with contractor full manpower support and oem service support from tamco, l and t for the amc-pm in compliance to the terms and conditions and pm checklist attached in this rfx. equipment : tamco medium voltage switchgear, l and t low voltage switchgear and its auxilliaries including capacitor ank, protection relays, vts, c ts etc with full manpower support and oem service support from tamco, l andt for the amc-pm monthly: 1 day per visit x 8 visits per yea r 8 days all attachments oq, terms and conditions, nda and amc pm checklist as attached online with this rfx., shall e
supply of motor details type: 3057.180-0021, 1.5kw, 3 phase, 50hz, 400v, connection: star, 3.6a, rpm: 2865, make: flygt. rewinding/repairing of motor and assemling the complete pump set. all required measurements to e recorded after repair jo. any other activity seems nece ssary for the proper operation of the motor should e executed. detailed repair report to e sumitted after the repair work containing all recorded parameters. warranty of one year to e provided for the repair and rewinding work.contact mohamed salem: 04-32-27856/ 0 561485396
rectification of pressure switch scope of work include rectification, reset and testing pressure switch on site. pressure s witch to e rectified and tested. cylinder to e refilled if required. qty: 1 no. cylinder model: ig 100 make: lpg, spain for site co ordination and ptw, contact eng. sherief 0529219010 other enquiries, contact eng. reem, 04-8892156, 050-2272767
supply and install hq nets nylon polypropylene with supports completely to the satisfaction of dewa engineer. in addition, to cover the roof for protection of lamps, pipes situated and around sound system, ehind footall cages, dead zones which are inaccessile and also at places where ullets can reach. contact yasir 050 4611 230
replacement of existing faulty and osolete ups at najma pumping station phase-3 with modular redundant 3x20 kva 2x20+1x20 kva - n+1 configuration ups and modular attery for 30 minutes autonomy at 32kw load as per attached specifications.
supply of load testing and certi. of chain lock ; 1 ton, load testing and certi . of chain sling ; 6 ton, load testing and certi. of manual chain manual chain hoist with trolley-0.5 ton, load testing and certi. of lifitng elt polyster weing sling ; 1 mtr, 2 ton, load testing and certi. of manual chain manual chain hoist with trolley- 5 ton, load testing and certi. of lifitng elt polyster weing sling ; 1 mtr, 2 ton, load testing and certi. of manual chain manual chain hoist with trolley-5ton
desludge hypo plant filtrated sea water asin and disposing outside dewa premises.. tank capacity 300m3. location : l desal hypo pla nt contact person dipesh chauhan 0522456862 dipesh.chauhan@dewa.gov.ae
design, farication, testing, supply and installation of md-1 as per attached oq, single line diagram and specifications for hatta o ld pumping station. qty: 1, design, farication, testing, supply and installation of 400 amp kwh meter panels as per attached drawings and specifications. quan tity: 2 nos, design, farication, testing, supply and installation of md-2 as per attached oq, single line diagram and specifications for hatta o ld pumping station. qty: 1
scope and requirements monthly amc-pm of tamco medium voltage switchgears and allen radley powerflex medium voltage variale frequency drives vfd ang in ghali lv swithchgear with required manpower and original equipment manufacturer oem service engineer support in hatta pumping station phase-2 per the attached oq, terms and conditions, scope and amc pm checklist. 8 visits per year with 1 day pe r visit all attachments oq, terms and conditions, nda and amc pm checklist as attached online with this rfx., shall e complied with compliance statement along with co. stamp and signature and uploaded. for work execution and further technical queries, scope and requirements: quarterly amc-pm