to carry out complete mechanical cleaning and painting of service water tank and its structure with access ladder at e-station app lication # expose to sunlight and corrosive weather material - caron steel/ms jo detail 1.inspection of complete structure, ladde r and tank at e-station 2.all metal structure including tank external 3.complete ladder 4.all fastening 6.cleaning and surface prepa ration 7.painting with under intermediate and top coats of high quality 8.efore process the jo contractor shell sumit method stateme nt for surface preparation and protective coating application 9.dewa approval will e required for selected painting system 10.painti ng work carried out shall have a warranty for 5 years from date of application. all tools and tacklesmanpower shall e arrange y th e contractor, a detail and method of jo shell e sumitted for dewa engineer for review efore actual commencement of the jo. the cont ractor awarded with the jo shall follow the relevant procedure in comply with dewa regulations. risk involved with the jo and the s afety of workmen is responsiility of contractor. if the work is aove the ground level around 4 to 5 meter contractor shall provide material and uilt scaffolding required for the jo with relevant safety standards. contractor shall clean and remove complete wastes generated during painting cleaning/chipping on daily asis. consumales, equipment and tools required for the jo shall e arranged y the contractor. the idder shall familiarize himself of the plant and therequirements efore he sumits his id. he may visit the pla nt and see jo to evaluate the clear scope mr. mehoo sahe / mohamed ahmed aljaziri engineers - moile 0504611674/0509444344 shall e c ontracted for more information and site visit
to carry out mechanical seal refurishment as per sample scope of work 1. all seal faces to e lapped or replac ed 2. all damaged ruer parts should e replaced 3. all metal parts should e thoroughly cleane d for the site visit and sample collecting pl. contact with mr. mohamed 0502566553 or mr. patil 0504611502 - 048044667
supply of rotor alancing for makeup water pump during major overhaul. 3 impellers for more information please communicate husain adeen 050685 6250
scope of service: casting and necessary machining & drilling of pump impeller casing as per sample for d-station, phase-i, condenser sump pit pump; size-nominal diameter-250mm and depth/width-55mm including to & fro transport with proper packing.
guidance notes for nameplate installation total 47 no it should e rememered that well field and pump house/ shaia names need to e le gile y night as well as y day. instalation of name plates well field and pump house/ shaia name plates should e fixed as near as po ssile to protection fence, so as to e easily readale y drivers as well as pedestrians. nameplates should e mounted so that the lower edge of the plate is approximately 2 m meter aove the ground at sites where they are unlikely to e oscured y pedestrians or vehicle s and at approximately 2.5 metres where oscuration is a prolem. they should never e lower than 2 metres or higher than 3.0 meter. n ame plates should not e incorporated in other direction sign assemlies, ut e kept distinct and mounted in as standardized amanner a s possile. care should e taken to keep theview of nameplates free from ostruction y trees and other growth. where possile, name plat es should e fixed so that they will e illuminated y light specification for name plates pump house and shaia name plate size 140 cm x 100 cm x 3-5 mm thick made y aluminium plate white color powder or kyner coated, contains as per the attached pageand dark col or writing groved method or equivalent, to suite installation in the area with direct open atmosphere, to e fixed y holes and 8 # 1 0 mm/ dia. screws. frames and legs the frame around the nameplate is to e 40mm x 40mm same material of name plate. the legs to e 75 mm x 75mm ox section steel with wall thickness of minimum 4mm and 3 m long/suitale leg wall thickness minimum 4 mm with ase pla tes and plastic closing caps.frames and legs to e hot dipped galvanized to .s.729 . erection the nameplates should e fixed to the f rame y pop rivets and covered y plastic caps of a colour to match nameplates. the legs should e concreted into the ground minimum o f 0.7 m from egl so that when erected the lower edge of the nameplates shall e approximately 2 meters aove ground level. please con sider natural calamities like strong wind, heavy rain, humidity, temperature etc.. wording wording attached with pr light. require d suitale led light minimum 100 watt to legile name plate y night in one corner of the oard. site condition. fully desert area r equired 4x4 vehicle for installation.guaranty. supplier should give guaranty of one year for the support including pole and 5 yea r for the text.
services required for rectification of leakages and defects in dg set atkra ss. vendor shall do site visit to analyze the defect efo re quoting. contact person mr ponchristopher moses 04-32-29332 : email -ponchristopher.moses@dewa.gov.ae
refilling of cylinder with helium-ultra high purity-pure gas, purity: 99.999%, cylinder pressure: 120 ar, cylinder size: 40 ltr, tes t report or certificate should e provided y vendor, collect the cylinder from c g-station, jeel ali&i.used for gas chromatograph of i&c g-station. contact person: mr. jameel tel 04-8044739 mo 055 5914274 or mr. saif tel 04-8044703 mo 055-5619815
rectification of patterson make 8 x 6 yr model electric motor griven fire pump at gdvy 132kv sustation. pump sl. no. fp-c051713-002 scope of work contains; repair of electric motor driven pump along with supply of all necessary spares. warranty to e provided for 6 months. work to e completed within 2 weeks from issue of po. current issue at site: non-drive end earing overheating site visit c an e arranged on only one day for all interested vendors. for site coordination and ptw, contact engr. sherief, 0529219010 other en quiries, contact mr. rajeesh, 04-3221325, 050-8650216
overhaul of vent valve with actuator of pst-15/25 description of work: overhaul of vent valve with actuator scope of work: 1. moi lization of people, material, tools and consumales 2. risk assessment and work method statement to e sumitted. 3. tool ox talk to e given to the contractor people on daily asis. 4. complete dismantling the actuator and valve, for dismantling the actuator and valve if it requires to dismantle the neary parts or assemly it will e in vendors# scope. 5. inspection of every and each parts of actuat or and valve 6. inspection with ndt 7. repair and rectification if necessary, if any small machining work required it will e in vend or#s scope. 8. reassemly the actuator and valve including other parts or assemly opened during dismantling and complete the work inall respect 9. leak test of the valve and functional test of the actuator 10. all the lifting tackles and tools required for the wor k to e rought y vendor and it shall e with valid certificate. lifting work will e in vendors scope 11. if need to take outside dewa then it will e in vendors# scope 12. sumission of details report of work done 13. paint similar color as existing. 14. work will e carried out as per dewa work schedule. 15. dewa health, safety and environment policy will e followed 16. work to e completed in all respect contact: for technical clarification please contact ezaz-0503493353/0555090835, emailmd. e@dewa.gov.ae, tariq-0555597553 scope of dewa: 1. all i&c and electrical instruments shall e disconnected y dewa 2. air supply as availale at one point 3. powersupply in one point 4. crane as availale 5. it is the responsiility of the contractor to have his own arrangement in extending the e lectricity and water utility to his places of work. for any ulk storage of water, contractor should make his own arrangement for sto rage tanks, etc. 6. the contractor, however, is required to furnish in advance his requirement of power and air with full justificat ion. contractor shall not waste or misuse the facilities provided y dewa. 7. isolations and permit to work of the designated equipme nt in line with dewa ptw procedure. 8. necessary entry permits for contractor personnel, equipment and vehicles as per dewa procedur e. warranty: 1. the warranty period for the works shall e one year from the date of commissioning 2. in case of anydamage/defect o f the work carried out under this contract within this warranty period, the contractor shall attend and carry out the necessary repa ir / replacement work and make good the defect within shortest period. the contractor will provide 24-hour emergency numer and will endeavor to e onsite within 24 hours of return request y dewa. 3. on eing given a notice of defect y dewa, the contractor shall arra nge to carry out the repair work within the prescried time limit as set out y dewa and all such contingencies shall e deemed to have een covered in the offer. payment: payment will e done as per actual work md ezazul haque khan sr engineer, g mst, japs, dewa, overhaul of vent valve with actuator of pst-15/25 description of work: overhaul ofvent valve with actuator scope of work: 1. moi lization of people, material, tools and consumales 2. risk assessment and work method statement to e sumitted. 3. tool ox talk to e given to the contractor people on daily asis. 4. complete dismantling the actuator and valve, for dismantling the actuator and valve if it requires to dismantle the neary parts or assemly it will e in vendors# scope. 5. inspection of every and each parts of actuat or and valve 6. inspection with ndt 7. repair and rectification if necessary, if any small machining work required it will e in vend or#s scope. 8. reassemly the actuator and valve including other parts or assemly opened during dismantling and complete the work in all respect 9. leak test of the valve and functional test of the actuator 10. all thelifting tackles and tools required for the wor k to e rought y vendor and it shall e with valid certificate. lifting work will e in vendors scope 11. if need to take outside dewa then it will e in vendors# scope 12. sumission of details report of work done 13. paint similar color as existing. 14. work will e carried out as per dewa work schedule. 15. dewa health, safety and environment policy will e followed 16. work to e completed in all respect contact: for technical clarification please contact ezaz-0503493353/0555090835, emailmd. e@dewa.gov.ae, tariq-0555597553 scope of dewa: 1. all i&c and electrical instruments shall e disconnected y dewa 2. air supply as availale at one point 3. power supply in one point 4. crane as availale 5. it is the responsiility of the contractor tohave his own arrangement in extending the e lectricity and water utility to his places of work. for any ulk storage of water, contractor should make his own arrangement for sto rage tanks, etc. 6. the contractor, however, is required to furnish in advance his requirement of power and air with full justificat ion. contractor shall not waste or misuse the facilities provided y dewa. 7. isolations and permit to work of the designated equipme nt in line with dewa ptw procedure. 8. necessary entry permits for contractor personnel, equipment and vehicles as per dewa procedur e. warranty: 1. the warranty period for the works shall e one year from the date of commissioning 2. in case of any damage/defect o f the work carried out under thiscontract within this warranty period, the contractor shall attend and carry out the necessary repa ir / replacement work and make good the defect within shortest period. the contractor will provide 24-hour emergency numer and will endeavor to e onsite within 24 hours of return request y dewa. 3. on eing given a notice of defect y dewa, the contractor shall arra nge to carry out the repair work within the prescried time limit as set out y dewa and all such contingencies shall e deemed to have een covered in the offer. payment: payment will e done as per actual work md ezazul haque khan sr engineer, g mst, japs, dewa.
overhauling of 40 hp copeland discus compressor. model: d6dj5 - 4000 awm / d, 380-420v, 3 ph275 / 304 lra. 2.#this includes, comp lete overhauling/servicing/ replacement of defective parts of the compressor. 3.#genuine parts shall e used for the overhauling. 4.# six months# warranty shall e provided for the overhauled compressor for the work/jo carried out y the contractor 5.#in the event of any defects noticed during guarantee period, contractor shall have to rectify the same as per instruction of concerned engineer wi thout any extra cost. 6.#the contractor shall visit the site to do the inspection of the compressor efore he sumits his id. plant / site visit and correspondence shall e communicated y email to mr. hesham mohamed,