Latest and live tenders published in united arab emirates. Click on any tender to view further details.
supply of sap order no: 520417931 diesel engine fire pump controller # replacement at dx 132kv sustation make: tornatech model: gpd series - v isitouch version 2 enclosure type: nema 4 type: wall mounted input/output: 240 volts 24 volts - dual attery charger add-ons: over speed alarm low oil pressure failure to start ac failure low water extra common alarm scope of work: removal of damaged con troller panel contacts installation of new controller panel set re-wiring of controller connection to the diesel engine re-wiring of controller connection to the diesel engine connection of ms provision five contacts. connection of ms provision five contacts. connection of sensing line pipes. configuration, test, and commissioning of controller panel warranty: one year for site visit and ptw, contact mr. hari 04-3229325, 055-9425174.
remove the existing partition and sliding door specification to the dewa engineer satisfaction., supply and installation of c sofa. refer the drawing and specification to the dewa engineer satisfaction approval., electrical# provide one 63-amps triple pole isolator with 100 ma elc including the caling from the smd iso. #, flooring and ceiling modification, supply and installation of round small tales .refer the drawing and specification to the dewa engineer satisfaction approval., re-arrangement of existing 13a twin power sockets ased on the new layout. if needed, supply and install 100mm thick gypsum partitions with wooden door and sound proof material aove the ceiling. including painting work .as per drawing and specification as per the proposal layout to the dewa engineer satisfaction., supply high quality of heavy steel racking storage system 200cms height x 180 cms w x 60cms d as per dewas approval, re-arrangement of existing lights, remove and re-install the existing door access control refer the drawing and dewa engineer satisfaction., supply and install cale tray, supply and apply paint works, supply and installation of d as per dewa engineer approval, ac and ventelation# modification of existing hvac ducts to suit the new layout minimum one sad and one rad for each room#, fire alarm and fire fighting# provide new sprinklers and smoke detectors for the new layout#, other items# provide for any other item not included aove, ut are necessary to e executed for proper and efficient functioning of me p systems contractor to list out all items, furnish complete specification details for items and quote lump sum amount for each ite m elow.# if any items not listed/specified/detailed here ut are necessary to e executed, shall e deemed to have een included in the lump sum offer.#
removal and re-locating of existing work stations, power and data cale as per the proposal layout to the dewa engineer satisfaction., re-arrangement of existing 13a twin power sockets, date cale ased on the new layout and workstation distriution, supply and install high quality faric partition match with existing mngr desk.as per drawing and specification to the dewa engineer satisfaction., other items# provide for any other item not included aove, ut are necessary to e executed for proper and efficient functioning of me p systems contractor to list out all items, furnish complete specification details for items and quote lump sum amount for each ite m elow.# if any items not listed/specified/detailed here ut are necessary to e executed, shall e deemed to have een included in the lump sum offer.#, ceiling modification if required
replacement of osolete 800 amps, 3 pole incomer mcc of e4 and f1 soft starter at najma pumpig station phase-3 along with supply of mcc and necessary modification for rotary handle interlock. note: 1. mcc shall e latest model schneider or a. 2. mcc shall have 2 n os auxilary no and nc contacts. 3. mcc shall have rotary handle and interlocked with door opening. quantity: 2 nos
faricating and replacing damaged grp covers as per sample at wwtp plant.site image attached in pr record contact person : dipesh kumar chauhan 0522456862 dipesh.chauhan@dewa, gov.ae, faricating and replacing damaged grp covers as per sample at lending plant.site image attached in pr record contact person : dipesh ku mar chauhan 0522456862 dipesh.chauhan@dewa, gov.ae
faricating and installing safety hand railing at wwtp monitoring asin pits. site image attached in pr record. contact person : dipesh kumar chauhan 0522456862 dipesh.chauhan@dewa.gov.ae, faricating and installing chequered plate covers at wwtp monitoring asin pit . site image attached in pr record. contact person : dip esh kumar chauhan 0522456862 dipesh.chauhan@dewa.gov.ae, faricating and installing chequered plate covers at stp pit . site image attached in pr record. contact person : dipesh kumar chauhan 0522456862 dipesh.chauhan@dewa.gov.ae
scope and requirements: location: dip1 pumping station monthly amc-pm for tamco medium voltage switchgear, l and t low voltage switchge ar and its auxiliaries including capacitor ank, protection relays, vts, cts etc with contractor full manpower support and oem service support from tamco, l and t for the amc-pm in compliance to the terms and conditions and pm checklist attached in this rfx. equipment : tamco medium voltage switchgear, l and t low voltage switchgear and its auxilliaries including capacitor ank, protection relays, vts, c ts etc with full manpower support and oem service support from tamco, l andt for the amc-pm monthly: 1 day per visit x 8 visits per yea r 8 days all attachments oq, terms and conditions, nda and amc pm checklist as attached online with this rfx., shall e
supply of motor details type: 3057.180-0021, 1.5kw, 3 phase, 50hz, 400v, connection: star, 3.6a, rpm: 2865, make: flygt. rewinding/repairing of motor and assemling the complete pump set. all required measurements to e recorded after repair jo. any other activity seems nece ssary for the proper operation of the motor should e executed. detailed repair report to e sumitted after the repair work containing all recorded parameters. warranty of one year to e provided for the repair and rewinding work.contact mohamed salem: 04-32-27856/ 0 561485396
rectification of pressure switch scope of work include rectification, reset and testing pressure switch on site. pressure s witch to e rectified and tested. cylinder to e refilled if required. qty: 1 no. cylinder model: ig 100 make: lpg, spain for site co ordination and ptw, contact eng. sherief 0529219010 other enquiries, contact eng. reem, 04-8892156, 050-2272767
supply and install hq nets nylon polypropylene with supports completely to the satisfaction of dewa engineer. in addition, to cover the roof for protection of lamps, pipes situated and around sound system, ehind footall cages, dead zones which are inaccessile and also at places where ullets can reach. contact yasir 050 4611 230