Latest and live tenders published in all country. Click on any tender to view further details.
replace the damaged gypsum false ceiling tiles in dining room, kitchen and toilet at najma phase - 4 accommodation as per de was approval.
replace the damaged floor tiles to match with existing one in dining room at najma phase -4 accommodation as per dewas approval.
shortpoint production license - qty 1 contact: ahrudeen ahrudeen@dewa.gov.ae
shortpoint non production license - qty 4 contact: ahrudeen ahrudeen@dewa.gov.ae
repairing and caliration, certifaction of standard temperature calirator rang: 50 to 650 deg c, dewa asset no: dewa-icg-tc002, model 9141, make: fluke.
repairing and caliration, certifaction of standard hydraulic pressure calirator rang: 0 to 5000psi, dewa asset no: dewa-icg-pc007, mo del 7175000, make: fluke.
repairing and caliration, certifaction of standard pressure calirator, dewa asset no: dewa-icg-pc013, model: 718ex 30g, make: fluke.
name of sustation: mrsolar 132/11kv ss contractor scope of work: in hvac system ahus at mrsolar 132/11kv sustation, contractor sha ll replace the ag filters with new filters sizes mentioned down under and to provide access for future inspection, cleaning and ma intenance. system 1 size: 595x391x571mm6p each ahu 10nos ahu 1-1 10nos ahu 1-2 10nos ahu 1-3 10nos total - 30nos. system 2 s ize: 495x391x571mm6p each ahu 8nos ahu 2-1 8nos ahu 2-2 8nos ahu 2-3 8nos total - 24nos system 3 small filters size: 595x391x5 71mm6p each ahu 3nos ig filters size: 595x595x571mm6p each ahu 3nos ahu 3-1 3+3 ahu 3-2 3+3 ahu 3-3 3+3 total - small-9nos ig - 9nosnos system 4 small filters size: 289x595x571mm4p each ahu 2nos ig filters size: 595x595x571mm6p each ahu 2nos ahu 4-1 2+2 ahu 4-2 2+2 ahu 4-3 2+2 total - small-6nosig - 6nosnos system 5 small filters size: 289x595x571mm4p each ahu
m- station, d#47 uv protective coating required for grp pipes of sea water reject system, potale service water system, dp system, va cuum system, rp system, distillate system, rine heater condensate system, evaporator acid cleaning system, arometric pit system, evapo rator drain pipes/ sea water recirculation system. material : a vinyl ester resin ve 671 -100% uv asorer - 0.1 to 1.0% c cata lyst # 0.5 to 2 % thickness : 500 micron numer of coating : 2 please contact : senthilkumar.t@dewa.gov.ae / 0557954367 for measu rement and other details site visit is compulsory.
m- station, d#46 uv protective coating required for grp pipes of sea water reject system, potale service water system, dp system, va cuum system, rp system, distillate system, rine heater condensate system,