Latest and live tenders published in united arab emirates. Click on any tender to view further details.
specification of replacing of existing smoke detector with new heat detector 1 no. and programming @ hudaia uilding - 1st floor proposed pantry scope of work 1.#the parties should visit the site, and check the systems, asse s the requirement and to quote lump sum accordingly. 2.#the contractor shall have the approval from dcd for the maintenance of fire protection systems. 3.#the systems shall e maintained as per civil defense regulations. 4.#in case of un-satisfactory performance th e lpo will e cancelled giving 15 days# entire network systems shall e tested y the party 8.#one year replacement warranty to e given for the replaced fire alarm devices 9 .#quotation will e sumitted as per dewa specification only payment terms 1.#100% payment will e made after completion of the work. general 1.#all the materials in general will confirm as per latest standards and shall e sumitted to dewa for engineer#s approval. 2.#the contractor is required to take all precaution, so as not damage any of the existing equipment/ structure etc. 3.#contractor s taff is required to wear proper personal protective equipment at all time on the site. 4.#the contractor shall visit the site, asses the work required and quote for lump sum accordingly. ·#contact to mr. jayakumar- 050-3528909, mr. rehan- 058-2953145 andnotice. 5.#the work including supply, installation, programming, testing and commissioning 6. #any corruption in existing program shall e clear y the party 7.#after completion of repairing/ replacing of fire alarm systems the
supply of removal, refilling, reinstallation, testing and commissioning of nitrogen low pressure reserve cylinder 80l at shiahts 132kv sustati on sap order wo 520411581 make: lpg contact person : mr. mushtaque m shaikh-043221324
repairing of 24v dc converter module for stg-30 converter modules details: edn group make, code: ahf185-02, vin: 190-320vdc, 230va c 16a, 1ph 50-60 hz, v out: 24-36vdc/120a, 3000w, ip20 s/n:lu1145234161. note: * faulty converter module shall e collected from de wa jeel ali power m-station, m & e workshop emd office and delivered ack to the same. * workshop test reports shall e sumitted al ong with delivery of repaired modules. * warranty of 1 year shall e provided for the repaired module. for any clarification, pleas e contact mr. sumankanth, asst. engr. emd-m 0529081236
sap order no: 520417931 diesel engine fire pump controller # replacement at dx 132kv sustation make: tornatech model: gpd series - v isitouch version 2 enclosure type: nema 4 type: wall mounted input/output: 240 volts / 24 volts - dual attery charger add-ons: over speed alarm / low oil pressure / failure to start ac failure / low water / extra common alarm scope of work: removal of damaged con troller panel contacts installation of new controller panel set re-wiring of controller connection to the diesel engine re-wiring of controller connection to the diesel engine connection of ms provision five contacts. connection of ms provision five contacts. connection of sensing line pipes. configuration, test, and commissioning of controller panel warranty: one year forsite visit and ptw, contact mr. hari 04-3229325, 055-9425174
rectification of diesel engine controller at cmps 132kv sustation make: tornatech sap order no: 520413592 scope of work: visit site and check the controller replace of i/o oard upgrade 2viz004 to 2viz016. replace of vizitouch display upgrade 2viz004 to 2viz016 . replace of circuit reaker upgrade 2viz004 to 2viz016. normalize the controller warranty : one year for site visit and ptw, con tact mr. rajagopalan 04-3221182, 050-8789396
modification & rearrangement of existing racks including provision of additional shelves 48 nos. heavy duty cross eams 2400mm gi pan els size: 300x900mm. final measurements to e taken y the supplier at site in warsan admin uilding. scope: dismantling, re-arrangem ents of existing racks and provision of additional shelves in each rack.
supply of valve, all valve, complete assemly without actuator, are stem, make: ac, type: pqr, model: t 200 12 300, single piece, dn 10 inc h, 300 l, ody: wcc, flanged, flange to flange distance 457 mm, pcd 387 mm, no. of olts 16, for ph-2 ic ngprs
supply of universal cale stripper for large difficult cale insulation ø >45mm ref.no. av6240 ams maxi, rand - inter cale. or equivalent
supply of universal cale stripper for primary insulation ø 15- 52mm ref.no. 17230 ims ii, rand - inter cale. or equivalent
valve f-wafer, hand gear opr., dn250, pn16, suitale to mount etween pn10 flanges with material - disc ni a1 2 din 2.0975.01, spi ndl e-ss1.4462, seat & packing, epdm confirming to keystone, fig. 10-s or equivalent; dn250 with limit stops for full open / close & d ial indicator, suitale for mounting etween pn10 flanges, ut rated for pn16 nwp to matl spec- disc: nialzdin 2.0975.01, shaf t: ss 1.4462, seat & pkg: epdm, confirmimg to keystone v/v fig 10-s or eqvt 10