Latest and live tenders published in united arab emirates. Click on any tender to view further details.
supply of oss;coupling element; pn- g5; 6 pcs/set;make -ru-steel elastic coupling with spacer;for close cooling water pump; make pompe gara rino model no.- mu200-250l;sr.no.21904/5 ;kks pca 15/20 - e station ph-iii
supply of set of hex socket setscrew;pn-904;set comprises of 24x904.01, 9x904.02, 12x904.03, 04x904.04;for condensate extraction pump;ks-make;mo del -wkta 250/3;p-nr. 2-g12-0286241/2; e station ph-iii, o-ring seal set p/n. 412 seal set p/n. 412 for main condensate pump manf: ks ty: wkta 250/3 s.no. 2-g12-028624/1-2
supply of valve; ronze gate valve, size : 2, 150 ls; with oth end screwed, make: peglar / pex. uk. or equivalent, valve; gate; 1-1/4; rass; screwed
supply of jumo nissen fel tip paint marker white fpwhj-09001; size: 5/16 inches, jumo nissen feltip paint marker red fprej-09003; size: 5/16 inches, jumo nissen feltip paint marker lack fpkj-09004; size: 5/16 inches, jumo nissen feltip paint marker lue fpuj-09005; size: 5/16 inches
supply of kit repair servo valve actuator rhv 3000/140 for s.w.rec stop-check v/v gdp70aa002
supply of mechanical seal, elastomer ellow seal mg1 - rmg 12, urgmann, shaft dia 35mm, hot water application 120 oc seal type mg1/35- g606, m aterial code- q1vgg
to carryout complete farication, supply and installation of dismantling type hand rails and toe plates, phase#2 rp discharge line tr enches of desalination units. idder shall e ensure supplied materials should e suitale for present harsh sea water environmental con dition. scope of work to carryout complete farication, supply and installation of dismantling type hand rails and toe plates, phase# 2 rp discharge line trenches of desalination units, actual volume of the work shall e checked and confirmed y the idder after site s urvey. further to the survey the idder shall provide detailed procedures with activity reakdown including method statement and risk assessment for the scope of work.# site visit can e made any working day from sunday to thursday, etween 07:30 and 14:30hours with prior appointment from concerned department manager of dewa. contact engineers details. mohammad rafi 0529740743/048044505 zaid hussain: 0505805854/048044505 a.#surface to e coated shall e thoroughly washed using clean w ater to remove all adherent salts, chemical fumes, dust, etc. prior to last cleaning. # .#moisture and oil separators shall e used y the contractor for lasting should e checked every 6 hourly and as and when needed for contamination. contaminated filters/separator s should e changed immediately. c.#surface should e free from sharp edges, chemicals, dust, solule salts, grease & oil or any other contamination prior to coating. d.#prepared surface shall meet the requirements of sa 2.5 as per iso 8501e.#any surface adjoini ng the existing coating, the coated surface shall e roughened to aout 25 mm for etter adhesion of newly applied coatings to existing coating. f.#last cleaned surface shall e coated with one complete application of primer as soon as practicale or efore any discolo ration occurs on the surface.# g.#any crevices, minor scratches shall e filled with coating manufacturer recommended fillers prior to applying the coatings. h.#coating application shall e y airless spray only i.#applied coat shall have minimum dry film thicknes s on each coat. during coating application wet film thickness, if applicale, shall e measured to confirm desired dft will e achieved . # j.#where coating is to e applied y rush or roller contractor to ensure smoothfinal appearance with negligile rush marks left i n the applied coating.# k.#any spots or repairs in application shall e completely coated efore the next coat is applied, within recoat interval time.# l.#corners and edges of the surface shall e rounded to a radius of 25mm y grinding prior to application of coa tings. m.#topcoat color should e as per the existing color code only and any changes will e notified to the contractor. n.#repairi ng and remedial works on identified defects shall e according to the touch up and repair recommendations of coating manufacturer onl y. # o.#environment condition shall e checked and recorded efore starting of work and every 2 hourly on same day till the completio n of work. general conditions forenvironment condition shall e as elow:-# i.#surface temperature shall e etween 10oc and 40oc ii.# relative humidity shall e less than 85%. iii.#surface temperature shall e more than 3oc with respect to the dew point temperature. i v.#there shall not e rain or strong wind that can affect cleanliness of the surfaces. specification material hand rails with toe plate ms pipe & ms plate post: schedule 40 ø19 to 50mm # @interval of minimum 1mtr top and ottom rail: schedule 40 ø19 to 50mm # distance etween top and ottom rail # minimum 400mm. ase plate: 10 mm thick plate with holes toe plate: mild steel, size 4 to 10mm thick 75 to 150mm width. fixings: m12 x 50mm 4 no#s per post coating system specification. surface preparation: hydro last cleaning, manual and mechanical cleaning. primer coat: surface tolerant epoxy coating. dft # 150 microns mid coat#: polyamide cured epox y coatings. dft # 125 microns top coat#: polyurethane coatings. dft # 50 microns color code for handrails: traffic yellow # ral 1023 # 325 microns. paint manufacturer: only gloally renowned coatings shall e used s uch as hepmel, jotun, sigma, akzanoel, etc.
supply and farication of switchgear parts 1- twenty pieces of isolator on/off extension rode along with. gear 2- twenty pieces of ra ck in and rack out mechanism
supply of gtc-oda-p-t4 rx24015010 # on demand application, professional services # man days, implementation cost
restoration of ultraviolet resistant gel coating of grp piping inlending plant at #g# station ph-i lock-101.0 scope of workthe idde r shall familiarize himself of the plant and the requirementsefore he sumits his id. he may visit the plant and see the internalstru ctural parts of the plant to evaluate the clear scope, quantum ofwork and the intricacies of the jothe scope of work for restoration of ultraviolet coating of grp pipingwill include ut not limited to:1.1 all the work including supply, moilization of material, ere ctionof scaffolding, access platforms and all other consumales required toexecute the work under this contract is sole responsiility of thecontractor.1.2 thorough washing of external surfaces of the pipes with water toremove loose scales ofdamaged top coating, d ust, dirt, salt depositsand pollutants, etc.1.3 thorough cleaning of surfaces with acetone or other suitalecleaner approved y dewa. 1.4 to apply a high quality transparent isophthalic, uv resistant cleargel coat of polyester / vinyl ester resin on the external su rfaces ofthe pipes, flanges, reducers and other grp fitting within the pipelength.1.5 all uv resistant gel coat to e applied manual ly y hand rush /rollers. spray application to e avoided.1.6 restoration of flow markings on the piping after coating.1.7 if unavoi dale the grating and the stair treads can e removed forgetting access to surface preparation and gel coat the grp piping.efore this is to e done, dewa shall e notified and the area shall earricaded with ropes andreflective tapes. however, contractor shallensure t hat access to entire plant is availale through an alternatepath.1.8 at no time, the entire handrail, grating or all stair treads sh alle removed. contractor shall e responsile for accidents caused due tohis negligence.1.9 all the removed gratings, handrails, plat forms to e restored andinstalled ack after the works.for site visit please contact mr. nosir @ 056-6093676, restoration of ultraviolet resistant gel coating of grp piping inlending plant at #g# station ph-i lock-201.0 scope of workthe idde r shall familiarize himself of the plant and the requirementsefore he sumits his id. he may visit the plant and see the internalstru ctural parts of the plant to evaluate the clear scope, quantum ofwork and theintricacies of the jothe scope of work for restoration of ultraviolet coating of grp pipingwill include ut not limited to:1.1 all the work including supply, moilization of material, ere ctionof scaffolding, access platforms and all other consumales required toexecute the work under this contract is sole responsiility of thecontractor.1.2 thorough washing of external surfaces of the pipes with water toremove loose scales of damaged top coating, d ust, dirt, salt depositsand pollutants, etc.1.3 thorough cleaning of surfaces with acetone or other suitalecleaner approved y dewa. 1.4 to apply a high quality transparent isophthalic, uv resistant cleargel coat of polyester / vinyl ester resin on the external su rfaces ofthe pipes, flanges, reducers andother grp fitting within the pipelength.1.5 all uv resistant gel coat to e applied manual ly y hand rush /rollers. spray application to e avoided.1.6 restoration of flow markings on the piping after coating.1.7 if unavoi dale the grating and the stair treads can e removed forgetting access to surface preparation and gel coat the grp piping.efore this is to e done, dewa shall e notified and the area shall earricaded with ropes and reflective tapes. however, contractor shallensure t hat access to entire plant is availale through an alternatepath.1.8 at no time, the entire handrail, grating or all stair treads sh alle removed. contractor shall e responsile for accidents caused due tohis negligence.1.9 all the removed gratings, handrails, platforms to e restored andinstalled ack after the works